A5 4152VL04 Technical Ordering Data Sheet.pdf
PDF 113 KB Posted
- Attached to
- NUCLIDE GAMMA CALIBRATION
- Solicitation number
- 4152-VL00
About this file
The document provided is an Ordering Data Sheet for a Nine nuclide gamma calibration source in the form of a 500 ml solid epoxy matrix. The key details are:
The source contains a mixture of nine radioactive nuclides - Cd-109, Co-57, Te-123m, Cr-51, Sn 113, Sr-85, Cs-137, Y-88, and Co-60 - with the activity ratios selected to provide similar count rates on typical coaxial high-purity germanium detectors. The total source activity shall be 3.0 microcuries (-15%, +0%) and the reported radioactivity uncertainty of each nuclide shall not exceed 5% at the 99% confidence level. The vendor must ensure the source activity is not greater than the exempt quantity per 10 CFR 30. Surface contamination levels on the source and packing materials must be less than 450 pCi/100cm^2. The source requires a Certificate of Calibration that documents its NIST traceability, nuclide activities, density, volume, and serial number. The source will be shipped by the vendor to the Puget Sound Naval Shipyard in Bremerton, Washington.
The Ordering Data Sheet is related to a pre-solicitation for "NUCLIDE GAMMA CALIBRATION" posted by the Department of the Navy, Naval Supply Systems Command. Interested parties are requested to provide their company information to receive the solicitation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ORDERING DATA SHEET – GENERAL
NOUN NAME: RADIOACTIVE SOURCE
DESCRIPTION:
1 ea Nine nuclide gamma calibration source in the form of 500 ml solid epoxy matrix in customer provided 500 ml Marinelli beaker.
-Nuclide mixture: Cd-109, Co-57, Te-123m, Cr-51, Sn 113, Sr-85, Cs-137, Y-88, Co-60 with nuclide activity ratios selected to provide similar count rates on typical coaxial high-purity germanium detectors.
-Active volume: 500 ml
-Density of solid: 1.5 g/cc.
-Total source activity shall be 3.0 microcuries (–15%, +0%)
-The vendor must insure that the source activity is not greater than exempt quantity per 10 CFR 30.
-The reported radioactivity uncertainty of each nuclide shall not exceed ± 5% at the 99% confidence level.
-Surface contamination levels on the source and packing materials must be less than 450 pCi/100cm^2.
MATERIAL: N/A
MANUFACTURER/VENDOR P/N: N/A
QUANTITY: 1 each
ADDITIONAL NOTES:
CERTIFICATION
-A Certificate of Calibration is required for the source and shall be provided from the vendor that documents:
-The source shall be National Institute of Standards and Technology (NIST) traceable
-The total activity of the source, reference time, and date
-The activity, gamma emission rate, and associated uncertainty of each nuclide
-The activity of any gamma emitting impurities detected
-Density and volume of active volume
-The vendor assigned source serial number
-ISO Classification
-The results and date of leakage testing
SHIPPING REQUIREMENTS
Source will be shipped by vendor to:
(N3999H) Puget Sound Naval Shipyard & IMF
1400 Farragut Avenue, Building 450, Door 2
Bremerton, WA 98314-5001
Attn: C/2380.4R - R. Nicole Van Den Eijkel (360) 801-6048
POC: C/105.55 Marc Sobolesky (360) 340-4797
Prior to shipping, vendor will make voice contact via phone with Nicole Van Den Eijkel or their representative at (360) 476-
3520 with date of shipment and shipment tracking information (i.e. UPS/FEDEX tracking numbers). A phone message will not be considered voice contact.
Changes to specification or other technical requirements are not allowed without Shipyard approval via the Administrative
Contracting Officer (ACO).
JOB ORDER
991566SOUR
KEY OP
H01
KO ITEM
REV
IDN
4152VL04
IDN REV
2305.3 Form; Rev 02/2020
File details come from the government source that posted it. Updated .