This document is an Ordering Data Sheet for a nine-nuclide gamma calibration source in the form of a 1000 ml solid epoxy matrix. The source contains a mixture of Cd-109, Co-57, Te-123m, Cr-51, Sn-113, Sr-85, Cs-137, Y-88, and Co-60 with activity ratios selected to provide similar count rates on typical coaxial high-purity germanium detectors. The total source activity shall be 3.0 microcuries (-15%, +0%) and the reported radioactivity uncertainty of each nuclide shall not exceed 5% at the 99% confidence level. The vendor must ensure the source activity is not greater than exempt quantity per 10 CFR 30. The source will be shipped to Puget Sound Naval Shipyard & IMF in Bremerton, WA, and the vendor must make voice contact prior to shipping with the specified point of contact.

This Ordering Data Sheet is associated with a pre-solicitation for a "NUCLIDE GAMMA CALIBRATION" requirement from the Department of the Navy Naval Supply Systems Command. The solicitation number is 4152-VL00, and interested parties are requested to provide their company name, CAGE code, and contact information to receive the solicitation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ORDERING DATA SHEET – GENERAL

NOUN NAME: RADIOACTIVE SOURCE

DESCRIPTION:

1 ea Nine nuclide gamma calibration source in the form of 1000 ml solid epoxy matrix in customer provided 1000 ml bottle.

-Nuclide mixture: Cd-109, Co-57, Te-123m, Cr-51, Sn-113, Sr-85, Cs-137, Y-88, Co-60 with nuclide activity ratios selected to provide similar count rates on typical coaxial high-purity germanium detectors.

-Active volume: 1000 ml

-Density of solid: 1.0 g/cc.

-Total source activity shall be 3.0 microcuries (–15%, +0%)

-The vendor must insure that the source activity is not greater than exempt quantity per 10 CFR 30.

-The reported radioactivity uncertainty of each nuclide shall not exceed ± 5% at the 99% confidence level.

-Surface contamination levels on the source and packing materials must be less than 450 pCi/100cm^2.

MATERIAL: N/A

MANUFACTURER/VENDOR P/N: N/A

QUANTITY: 1 each

ADDITIONAL NOTES:

CERTIFICATION

-A Certificate of Calibration is required for the source and shall be provided from the vendor that documents:

-The source shall be National Institute of Standards and Technology (NIST) traceable

-The total activity of the source, reference time, and date

-The activity, gamma emission rate, and associated uncertainty of each nuclide

-The activity of any gamma emitting impurities detected

-Density and volume of active volume

-The vendor assigned source serial number

-ISO Classification

-The results and date of leakage testing

SHIPPING REQUIREMENTS

Source will be shipped by vendor to:

(N3999H) Puget Sound Naval Shipyard & IMF

1400 Farragut Avenue, Building 450, Door 2

Bremerton, WA 98314-5001

Attn: C/2380.4R - R. Nicole Van Den Eijkel (360) 801-6048

POC: C/105.55 Marc Sobolesky (360) 340-4797

Prior to shipping, vendor will make voice contact via phone with Nicole Van Den Eijkel or their representative at (360) 476-

3520 with date of shipment and shipment tracking information (i.e. UPS/FEDEX tracking numbers). A phone message will not be considered voice contact.

Changes to specification or other technical requirements are not allowed without Shipyard approval via the Administrative

Contracting Officer (ACO).