A06_Drawings.pdf
PDF 1 MB Posted
- Attached to
- Tonopah Fence Gates Replacement Federal contract opportunity
- Solicitation number
- 140L3925Q0045
About this file
The document is a technical drawing set for a 30-foot telescoping gate system for the Tonopah Fence Gates Replacement project. The detailed drawings provide comprehensive specifications for a 24'W x 6'H gate with key components including:
Structural Details: The gate features a telescoping design with inner and outer panels, utilizing 2" x 2" aluminum tubes, a 5" HD aluminum channel, and a chain-driven mechanism. The system includes a counterbalance mechanism with specific post spacing (8'-8"), an overall gate length of 33'-7", and a stored panel length of 18'-11". Safety devices are specified, including photo eyes, induction loops, and a safety edge for the gate's operation. The drawings include precise layout plans for the gate operator pad, hanger assemblies, bottom guide assemblies, and catch mechanisms, with notes emphasizing mill finish and compliance with local codes and soil conditions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140L3925Q0045_Amd_0001.pdf | ||
| Questions___Answers_0001.docx | DOCX document | |
| Sol_140L3925Q0045.pdf | ||
| A06_Specifications.pdf | ||
| B03_DBA_Wage_Determination.pdf | ||
| Bid_Schedule.xlsx | XLSX spreadsheet | |
| A04_SOW.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B = COUNTERBALANCE
POST SPACING C/C
A = CLEAR OPENING
30' TELE-LEVER GATE WITH 40% C'BALANCE 1.70:1 CHAIN DRIVE
4'-0"
OVERLAP
G = STORED PANEL LENGTH
F
P
O S
T
H
E I G
H T
D = COUNTERBALANCE LENGTH
E
N
O M
I N
A L
G A
T
H
I G
H T
C = OVERALL GATE LENGTH
ELEVATION (GATE CLOSED POSITION)
PLAN VIEW (GATE CLOSED POSITION)
CATCH ASSEMBLY (SEE
DETAIL #3)
o f
T E
L E
S C
O P
IN
G
G A
T E
E X
A M
P L E
4" O.D.
POST (TYP.)
2" x 2" ALUM.
TUBE (TYP.)
CATCH ASSEMBLY (SEE
DETAIL #3)
CABLE TOP PRIMARY
MEMBER
GATE
OPERATOR
INNER PANEL
TELESCOPING CHAINTELESCOPING
SPROCKET
OUTER PANEL
DRIVE CHAIN
OPERATOR
DRIVE CHAIN
GATE
OPERATOR
INNER PANEL
OUTER PANEL
FENCELINE
1" x 2" ALUM.
TUBE (TYP.)
5" HD ALUM.
CHANNEL
NOTES:
1. GATE ELEVATION IS VIEWED FROM THE OUTSIDE OF THE SECURE AREA LOOKING IN.
2. FENCE LINE NOT SHOWN FOR CLARITY OF GATE SYSTEM.
3. GATE TO BE MILL FINISHED.
STORED PANEL LENGTH
CLEAR OPENING
CRITICAL DIMENSION CHART
COUNTERBALANCE POST SPACING
OVERALL GATE LENGTH
COUNTERBALANCE LENGTH
NOMINAL GATE HEIGHT
POST HEIGHT
E
F
G
B
D
C
A
NOMINAL GATE SIZE
24'W X 6'H
24' - 0"
8' - 8"
33' - 7"
9' - 7"
6' - 0"
7' - 6"
18' - 11"
FILLER PANEL
BARB ARM
BARB WIRE
4" O.D.
POST (TYP.,
BY OTHERS)
EXAMPLE DRAWING
CHAINLINK
FENCING
AutoCAD SHX Text Scale: None
AutoCAD SHX Text Scale: None
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
SUBJECT:
1'-6"
COMPANION
CATCHER ASSEMBLY3
3" GATE FRAME
4" O.D.
CATCH POST
GATE SECTION1
2" x 2" ALUM.
TUBE (ENDS)
2" x 2" ALUM. TUBE
(OUTER PANEL)
TOP PRIMARY MEMBER
W4 TRUCK ASSEMBLY
(SEE DETAIL #2)
2 GATE HANGER ASSEMBLY
HANGER BRACKET
W4 TRUCK
5/8" BOLT
CATCHER
1/2"-13 U-BOLT
5/8" HEX NUT
BOTTOM GUIDE WHEELS (TYP.)
5" HD ALUM. CHANNEL
OUTER PANEL BOTTOM
GUIDE BRACKET
BOTTOM GUIDE BRACKET
(SEE DETAIL #4/2)
4" O.D. POST
OPERATOR
INNER PANEL
TELESCOPING
CHAIN BRACKET
INNER PANEL
TELESCOPING CHAIN
ROLLERS (TYP.)
INNER PANEL
TELESCOPING CHAIN
DRIVE SPROCKET
OUTER PANEL DRIVE
SPROCKET
DRIVE CHAIN SUPPORT BRACKET
FENCE LINE POST
BOTTOM GUIDE ASSEMBLY4
4" O.D. POST
BOTTOM GUIDE
BRACKET
4" DIA. GUIDE WHEEL
OUTSIDEINSIDE
BARB ARM 2
o f
T E
L E
S C
O P
IN
G
G A
T E
E X
A M
P L E
AutoCAD SHX Text Scale: None
AutoCAD SHX Text Scale: None
AutoCAD SHX Text Scale: None
AutoCAD SHX Text Scale: None
AutoCAD SHX Text
PROJECT:
12"4 1/2" 4 1/2"
3 1/2"
10 1/2"
18 13/16"
21"14 5/16"
12"
B = COUNTERBALANCE POST SPACING C/C
A = CLEAR OPENING
M I N
21"
OPERATOR PAD LAYOUT PLAN1
2 OPERATOR FRONT ELEVATION
OPERATOR SIDE ELEVATION3
OUTSIDE
INSIDE OPERATOR PAD
PEDESTAL
GATE FRAME
NOTES:
1. OPERATOR PAD DEPTH TO BE
MINIMUM OF 24" AND IN
ACCORDANCE WITH ALL LOCAL
CODES AND SOIL CONDITIONS.
ONE HP
GATE OPERATOR
OPERATOR
PAD (NOTE 1)
PEDESTAL
GATE POST
GATE FRAME
GRADE
ONE HP
GATE OPERATOR
OPERATOR PAD
PEDESTAL
CHAIN SUPPORT
BRACKET ATTACHED
TO 1" x 2" VERTICAL
INCOMING CONDUIT
FENCE LINE
o f
T E
L E
S C
O P
IN
G
G A
T E
E X
A M
P L E
AutoCAD SHX Text Scale: None Right Hand Shown, Left Hand Opposite
AutoCAD SHX Text Scale: None
AutoCAD SHX Text Scale: None
AutoCAD SHX Text
PROJECT:
o f
S a fe ty
D e vi c e D e ta ils E
X A
M P
L E
SAFETY DEVICES LAYOUT
CLEAR OPENING
PHOTO EYES
BACKSPACE
PHOTO EYES
SAFETY EDGE
CLEAR OPENING
PHOTO EYES
INDUCTION
LOOP
INDUCTION
LOOP
INDUCTION LOOP
SECURE GATED
PARKING AREA
PUBLIC
PARKING AREA
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
SUBJECT:
Scale: None
| Sheets and Views |
| 1R |
| 20250110_PN2_REV1.pdf |
| Sheets and Views |
| 2 |
| 20250110_PN3_REV1.pdf |
| Sheets and Views |
| 3 |
| 20250110_PN4_REV1.pdf |
| Sheets and Views |
| 4 |
File details come from the government source that posted it. Updated .