A06_Attachment_0006_HVAC_Equipment_List_140P5126Q0017_MALU_HVAC.pdf
PDF 37 KB Posted
- Attached to
- MALU FM HVAC MAINTENANCE SVC BASE + 4 OY
- Solicitation number
- 140P5126Q0017
About this file
This is an equipment schedule document that lists mechanical and HVAC components for a facility or project.
The schedule contains detailed specifications for multiple categories of equipment across various systems. Air handling units include six DAIKIN units (models BCVU0601, CAH011GDCM, BCVE0401, BCVE0401, and CAH013GDCM) designated AHU-1 through AHU-6. Outside air intake units consist of two GREENHECK FGI units (OAI-1 and OAI-2). The boiler schedule specifies one LOCHINVAR unit (model FTX400) identified as B-1. The air-cooled chiller is a DAIKIN unit (model AGZ008F) tagged as CH-1. The pump schedule includes four GRUNDFOS pumps with model AASG6S2ESBQOENX4 and AASG6S2ESBQQEHX4 for chilled water and hot water applications (CHWP-1, CHWP-2, HWP-1, HWP-2). The fan-powered box schedule lists one LIEBERT unit (model PX011UA1A8S9RZ) as AHU-3, and a DAIKIN fan coil (model FTKF12BVJU9) as AC-1. The fan schedule includes four GREENHECK exhaust fans with models SQ-120-VG, G-095-VG, and two CUE-160-VG units (EF-1 through EF-4). The condensing unit schedule specifies a LIEBERT unit (model MCS028) and a DAIKIN unit (model RKF12BVJU9). The variable air volume box schedule lists fifteen TITUS DESV units (VAV-1 through VAV-15).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VARIABLE AIR VOLUME BOX SCHEDULE
VAV-15 TITUS DESV
VAV-13 TITUS DESV
VAV-14 TITUS DESV
VAV-11 TITUS DESV
VAV-12 TITUS DESV
VAV-9 TITUS DESV
VAV-10 TITUS DESV
VAV-7 TITUS DESV
VAV-8 TITUS DESV
VAV-5 TITUS DESV
VAV-6 TITUS DESV
VAV-3 TITUS DESV
VAV-4 TITUS DESV
VAV-1 TITUS DESV
VAV-2 TITUS DESV
MCS028
RKF12BVJU9
AIR HANDLING UNITS
OUTSIDE AIR INTAKE UNITS
BOILER SCHEDULE
AIR COOLED CHILLER
PUMP SCHEDULE
FAN POWERED BOX SCHEDULE
FAN SCHEDULE
SQ-120-VG
G-095-VG
CUE-160-VG
CUE-160-VG
CONDENSING UNIT SCHEDULE
AASG6S2ESBQQENX4
AASG6S2ESBQQEHX4
AASG6S2eSBQQEHX4
PX011UA1A8S9RZ
FTKF12BVJU9
FTX400
AGZ008F
AASG6S2ESBQQENX4
BCVE0401
BCVE0401
CAH013GDCM
FGI
FGI
GREENHECK
GREENHECK
LIEBERT
DAIKIN
LIEBERT
DAIKIN
GREENHECK
GREENHECK
DAIKIN
GRUNDFOS
GRUNDFOS
GRUNDFOS
GRUNDFOS
GREENHECK
GREENHECK
LOCHINVAR
CU-1
CU-2
DAIKIN BCVU0601
DAIKIN
DAIKIN
DAIKIN
DAIKIN
EF-1
EF-2
EF-3
EF-4
CHWP-2
HWP-1
HWP-2
AHU-3
AC-1
B-1
CH-1
CHWP-1
AHU - 4
AHU - 5
AHU - 6
OAI - 1
OAI - 2
EQUIPMENT TAG Manufacturer Model
AHU - 1
AHU - 2 CAH011GDCM
File details come from the government source that posted it. Updated .