A.2.11.3 RTA 100% Design Submittal_Drawings with Option1.pdf
PDF 39 MB Posted
- Solicitation number
- W9128A22R0012
About this file
This document provides details on a federal contract solicitation for electrical distribution system upgrades on Meck Island, U.S. Army Garrison - Kwajalein Atoll in the Republic of the Marshall Islands. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Honolulu on March 25, 2022 under number W9128A22R0012. Interested offerors are invited to participate in a pre-proposal teleconference on April 1, 2022 to discuss the project and site information, as current travel restrictions prevent an in-person site visit. Offerors must register for the teleconference by March 30 by providing their name, email, and company details to the listed Points of Contact. The solicitation can be found on SAM.gov and interested parties should check for any updates.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5122505350285034
5979 5148
T1 T2
T3 T4
T5T6T7 T9
T10
G-001
C O
VE
R
S H
EE
T
J.
V
AN
SI
C
KE
L
L.
T
LI
LI
C . H
AY
W
AR
D
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
HONOLULU DISTRICT
MECK ISLAND, (USAG-KA)
ELECTRICAL DISTRIBUTION SYSTEM
FY22 U.S. MISSILE DEFENSE AGENCY
REPUBLIC OF THE MARSHALL ISLANDS
W9128A-16-D-0003
SEP 2020
B1
MECK ISLAND VICINITY MAP
TRUE N
SCALE NTS
CONTROLS DESIGNMECHANICAL DESIGNELECTRICAL DESIGN
DISTRIBUTION DESIGNSTRUCTURAL DESIGNCIVIL DESIGN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SI
LE
D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
PT
EM
BE
R
W
A-
-D
-0
AN
SI
D
FIRE PROTECTION DESIGN
Jefferson D. VanSickel
Digitally signed by Jefferson D. VanSickel DN: C=US, E=jeff.vansickel@powereng.com, O="POWER Engineers, Inc", OU=Generation Electrical Department, CN=Jefferson D. VanSickel Location: Meridian, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info: jeff.vansickel@powereng.com Date: 2020.09.01 13:05:44-06'00'
Jonathan Bader Digitally signed by Jonathan Bader
DN: C=US,
E=jonathan.bader@powereng.com, O=POWER Engineer's Inc., OU=POWER Engineer's Inc., CN=Jonathan Bader
Date: 2020.09.01 16:18:50-05'00'
Benjamin McKim
Digitally signed by Benjamin McKim Date: 2020.09.01 18:45:05 -06'00'
Jay T Higashi Digitally signed by Jay T Higashi DN: C=US, E=jay.higashi@coffman.com, O=Coffman Engineers, OU=Fire Protection Engineering, CN=Jay T Higashi Date: 2020.09.01 16:29:06-10'00'
William Keith Waller
Digitally signed by William Keith Waller DN: C=US, E=keith.waller@powereng.com, O="POWER Engineers, Inc.", OU=Generation Civil Department, CN=William Keith Waller Location: Hailey, ID Reason: I agree to the terms defined by the placement of my signature on this document Date: 2020.09.01 15:12:24-06'00'
Phillip Stenberg Digitally signed by Phillip Stenberg DN: C=US, E=phil.stenberg@powereng.com, O="POWER Engineers, Inc", CN=Phillip Stenberg Location: Meridian, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info: phil.stenberg@powereng.com Date: 2020.09.01 13:06:21-06'00'
Clay J. Stocklin Digitally signed by Clay J. Stocklin DN: C=US, E=clay.stocklin@powereng.com, O="POWER Engineers, Inc.", OU=Distribution Services Dept I, CN=Clay J.
Stocklin Location: Hailey, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info: clay.stocklin@powereng.com Date: 2020.09.01 14:51:10-06'00'
ROOF SNOW LOAD
WIND DESIGN DATA
EARTHQUAKE DESIGN DATA
GEOTECHNICAL INFORMATION
INTERNAL PRESSURE COEFFICIENTS
COEFFICIENT
COEFFICIENT
COEFFICIENT
SITE CLASS
BEARING CAPACITY
PSF
UFC DESCRIPTION VALUE UNITS
UFC 3-301-01 OCTOBER 2019 - "STRUCTURAL ENGINEERING"
PSF
RISK CATEGORY
RISK CATEGORY III
MPH
SECTION
(COMPONENTS AND CLADDING HAVE BEEN DESIGNED
BY A REGISTERED DESIGN PROFESSIONAL)
ULTIMATE DESIGN WIND SPEED,
INFORMATION IN TABLE 1 IS PROVIDED PURSUANT TO REQUIREMENTS OF
SEISMIC IMPORTANCE FACTOR,
WIND EXPOSURE CATEGORY
V ult
I w
WIND IMPORTANCE FACTOR,
P g
GROUND SNOW LOAD,
I e
S
S
S
MAPPED SPECTRAL RESPONSE ACCELERATION,
MAPPED SPECTRAL RESPONSE ACCELERATION,
GENERAL ABBREVIATIONS
MAX = MAXIMUM
MIN = MINIMUM
MSL = MEAN SEA LEVEL
MTL = METAL
NS = NEAR SIDE
NTS = NOT TO SCALE
OC = ON CENTER
OPP = OPPOSITE
PLCS = PLACES
PL = PLATE
PROJ = PROJECTION
QTY = QUANTITY
RAD = RADIUS
REF = REFERENCE
REQ'D = REQUIRED
SIM = SIMILAR
SLBB = SHORT LEG BACK TO BACK
SLV = SLEEVE
SP = SPACING
SPEC = SPECIFICATION
SS = STAINLESS STEEL
STD = STANDARD
T & B = TOP AND BOTTOM
THK = THICK
TOC = TOP OF CONCRETE
TOM = TOP OF MASONRY
TOS = TOP OF STEEL
TOW = TOP OF WALL
TS = TUBE STEEL
TYP = TYPICAL
UFC = UNIFIED FACILITIES CRITERIA
UON = UNLESS OTHERWISE NOTED
VERT = VERTICAL
W/ = WITH
WF = WIDE FLANGE
WL = WORK LINE
WP = WORKING POINT
AB = ANCHOR BOLT
BC = BOLT CIRCLE
BM = BEAM
BOS = BOTTOM OF STEEL
BP = BASE PLATE
CKHD = CHECKERED
CJ = CONTROL OR CONSTRUCTION JOINT
CL = CENTERLINE
CLR = CLEAR
CMU = CONCRETE MASONRY UNIT
COL = COLUMN
CONC = CONCRETE
CONN = CONNECTION
CONT = CONTINUOUS
DIA = DIAMETER
DBL = DOUBLE
DET = DETAIL
DWG = DRAWING
EA = EACH
EAE = ENGINEER APPROVED EQUAL
EF = EACH FACE
EJ = EXPANSION JOINT
EL = ELEVATION
EQ = EQUALLY
EW = EACH WAY
EX = EXISTING
EXT = EXTERIOR
FL = FLOOR ELEVATION
FS = FAR SIDE
GA = GAGE
GALV = GALVANIZED
GR = GRADE
HP = HIGH POINT
HSA = HEADED STUD ANCHOR
HORIZ = HORIZONTAL
INT = INTERIOR
INV = INVERT
JT = JOINT
LG = LONG
LLBB = LONG LEG BACK TO BACK
LLH = LONG LEG HORIZONTAL
LLV = LONG LEG VERTICAL
LP = LOW POINT
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS WITH CONTRACT DRAWINGS AND
WITH THE PHYSICAL CONDITIONS AT THE SITE, AND SHALL REPORT ALL DISCREPANCIES TO THE
ENGINEER FOR RESOLUTION. THE CONTRACTOR SHALL NOT CONTINUE ANY WORK RELATING TO SUCH
DISCREPANCIES WITHOUT ENGINEER APPROVAL.
2. CONTRACTOR SHALL MAKE EVERY REASONABLE EFFORT TO LOCATE ALL EXISTING UTILITIES AND
EXERCISE CARE TO PROTECT THEM FROM DAMAGE DURING EXCAVATION AND CONSTRUCTION.
3. SITE VISITS BY THE ENGINEER WILL NOT INCLUDE INSPECTIONS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR THE CONTRACTOR'S MEANS AND METHODS OF CONSTRUCTION, SEQUENCE OF
CONSTRUCTION, OR SITE SAFETY PROGRAMS.
4. STRUCTURAL NOTES SHALL BE USED IN CONJUNCTION WITH THE SPECIFICATIONS. WHERE
DIFFERENCES BETWEEN STRUCTURAL DRAWINGS, NOTES OR SPECIFICATIONS OCCUR, THE
SPECIFICATIONS SHALL GOVERN. IF DIFFERENCES OCCUR, THE CONTRACTOR SHALL REQUEST
IMMEDIATE CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
5. ALL DIMENSIONS ARE GIVEN IN FEET AND INCHES, UNLESS OTHERWISE NOTED.
6. WHERE REFERENCE IS MADE TO ASTM, AISC, ACI, UFC OR OTHER STANDARDS AND SPECIFICATIONS, THE LATEST EDITION IS INTENDED, UNLESS OTHERWISE NOTED.
7. STRUCTURES HAVE BEEN DESIGNED FOR OPERATIONAL LOADS ON THE COMPLETED STRUCTURE.
CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO PROTECT THE STRUCTURE DURING
CONSTRUCTION, INCLUDING, BUT NOT LIMITED TO, BRACING, SHORING, AND LOAD BALANCING WHERE
EXCESSIVE CONSTRUCTION LOADS MAY OCCUR.
8. CONTRACTOR SHALL PROVIDE ALL TEMPORARY SHORING AND BRACING REQUIRED FOR STABILITY
UNTIL THE STRUCTURE IS COMPLETE.
9. CONTRACTOR WILL EMPLOY AND PAY FOR THE SERVICES OF AN INDEPENDENT TESTING/INSPECTION
COMPANY TO PERFORM SPECIFIED INSPECTIONS AND TESTS IN ACCORDANCE WITH UFC 1-200-01
PARAGRAPH 2-17.2.
A. SPECIAL INSPECTOR SHALL BE APPROVED BY THE OWNER, THE LOCAL BUILDING INSPECTION
DEPARTMENT, AND BE ICC CERTIFIED FOR THE INSPECTIONS BEING PERFORMED.
B. EMPLOYMENT OF THE INDEPENDENT TESTING/INSPECTION COMPANY AND INSPECTION SHALL IN
NO WAY RELIEVE CONTRACTOR OF THEIR OBLIGATION TO PERFORM WORK IN ACCORDANCE WITH
REQUIREMENTS OF CONTRACT DOCUMENTS.
C. CONTRACTOR SHALL COORDINATE WITH THE INDEPENDENT TESTING/INSPECTION COMPANY TO
FACILITATE THE EXECUTION OF ITS REQUIRED SERVICES.
D. AFTER EACH INSPECTION AND TEST, THE INDEPENDENT TESTING/INSPECTION COMPANY SHALL
PROMPTLY SUBMIT TWO COPIES OF LABORATORY REPORT TO THE ENGINEER, AND TWO COPIES
TO THE OWNER.
E. STRUCTURAL STEEL FABRICATION SHALL BE IN COMPLIANCE WITH AISC 360, CHAPTER N.
163.0
III
D
1.0
1.25
0.32
0.09
D
2.4.7
SECTION 1613
Kd=0.85
Kz=1.08
Kzt=1.0
G=0.85
2.4.6
SECTION 1609
0.0
2.4.5
SECTION 1608
GENERAL STRUCTURAL NOTES
TABLE 1
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C T
N
O
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
SHEET ID
US Army Corps of Engineers
U S
A
R M
Y
C
O R
P S
F
E
N G
I N
E E
R S
S-001
G E
N E
R A
L
S
T R
U C
T U
R A
L
N
O T
E S
A
B B
R E
V I A
T I O
N S
A N
D
I N
F O
R M
A T
I O
N
R
E Q
U I R
E D
B
Y
I B
C
P
S
T E
N B
E R
G
J
T
U R
N E
R
C
W
E B
S T
E R
S
C
R E
A
R T
A
D
E S
I G
N
S
U B
M I T
T A
L
D I S
T R
I B
U T
I O
N
O
P T
I O
M
D
I F
I C
A T
I O
N S
S E
P
J A
N
RTA (100%) DESIGN SUBMITTAL
M E
K
I
L A
N D
U
S
A
R M
Y
G
A R
R I S
W A
J A
L E
A
O
L
U
S A
G K
A
C O
N T
A I N
E R
I Z
W
R
A
E
C T
R I C
S
T R
I B
U T
I O
N
F Y
S
M
I S
S I L
E
D
E F
E N
G E
N C
Y
R E
P U
B L
T
H
R
S H
A L
L
I S
L A
N D
S
H O
N O
L U
S
T R
I C
T
B L
E C
T P
O H
F T
S
H A
F T
E R
H
I
S E
P
W
A
D
A N
S I
D
1/27/22
1"
1"
MAXIMUM SIZE
COARSE AGGREGATE (INCHES)
CONCRETE FINISH
CONSTRUCTION
FORMWORK
ACCESSORIES
SPECIFICATIONS
CONCRETE MIX
TYPE OF STRUCTURE
REINFORCEMENT
MISCELLANEOUS
ALL OTHERS
FOOTINGS/SLABS ON GRADE
WALLS MORE THAN 10" THICK
ANCHOR BOLTS & EMBEDDED ITEMS
FLOOR FINISH
1. DESIGN AND CONSTRUCTION SHALL CONFORM TO AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING
CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY" (ACI 318), AND
"SPECIFICATIONS FOR STRUCTURAL CONCRETE" (ACI 301), LATEST EDITION.
2. LEAN CONCRETE (FOR USE AS STRUCTURAL FILL, AND IN MUD MATS AND DUCT BANKS) SHALL HAVE A
MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS. ALL OTHER CONCRETE SHALL BE NORMAL
WEIGHT CONCRETE WITH A MINIMUM COMPRESSIVE STRENGTH OF 5000 PSI AT 28 DAYS, UON.
PORTLAND CEMENT SHALL CONFORM TO ASTM C150, TYPE V, UON.
3. UNLESS A GREATER COVER IS INDICATED, COVER FOR REINFORCEMENT SHALL NOT BE LESS THAN
THE FOLLOWING (IN INCHES):
A. CONCRETE CAST AGAINST AND PERMANENTLY
EXPOSED TO EARTH
B. CONCRETE EXPOSED TO EARTH OR WEATHER:
NO. 6 THROUGH NO. 18 BARS ...................................................... 2-1/2
NO. 5 BAR; W31 OR D31 WIRE, AND SMALLER ............................ 2-1/2
C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
SLABS, WALLS, JOISTS:
NO. 14 AND NO. 18 BARS ............................................................... 1-1/2
NO. 11 BAR AND SMALLER ............................................................. 3/4
BEAMS, COLUMNS:
PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS ........... 1-1/2
SHELLS, FOLDED PLATE MEMBERS:
NO. 6 BAR AND LARGER ................................................................ 3/4
NO. 5 BAR; W31 OR D31 WIRE, AND SMALLER ........................... 1/2
4. REINFORCING BARS SHALL BE DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60. WELDED
WIRE FABRIC AND SPIRAL REINFORCEMENT SHALL CONFORM TO ASTM A1064.
A. ALL REINFORCING SHALL BE EPOXY COATED DEFORMED BARS PER ASTM A775.
5. CONTINUOUS REINFORCING #11 AND SMALLER, SHALL BE LAPPED AT SPLICES. LAP LENGTH OF
SPLICES SHALL NOT BE LESS THAN CLASS B SPLICE.
6. WHERE SPECIFIED ON THE CONTRACT DRAWINGS, ANCHOR BOLTS SHALL CONFORM TO THE
FOLLOWING:
· STAINLESS STEEL ASTM A193 GRADE B8M CLASS 1 AISI 316: Fu=75 KSI.
7. ALL DOWELS, ANCHOR BOLTS, EMBEDDED STEEL, ELECTRICAL CONDUITS, PIPE SLEEVES, PIPING, WATERSTOPS, INSERTS, GROUND RODS, AND ALL OTHER EMBEDDED ITEMS AND FORMED DETAILS
SHALL BE IN PLACE PRIOR TO START OF CONCRETE PLACEMENT.
8. ALL EXPOSED CONCRETE EDGES SHALL HAVE A ONE INCH CHAMFER AT 45 DEGREES.
9. TESTS AND SPECIAL INSPECTIONS, AS SPECIFIED BY CONCRETE NOTES TABLE 1, SHALL BE
PERFORMED FOR ALL CONCRETE WORK WITH A COMPRESSIVE STRENGTH GREATER THAN 2000 PSI.
10. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH TECHNICAL SPECIFICATION 03-30-00.
1. DESIGN, MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE FOLLOWING CODES AND
STANDARDS CONTAINED THEREIN, UNLESS OTHERWISE NOTED ON THE DRAWINGS.
IBC 2018 INTERNATIONAL BUILDING CODE
ACI 117 SPECIFICATION FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS
AND COMMENTARY
ACI 304 GUIDE FOR MEASURING, MIXING, TRANSPORTING AND PLACING CONCRETE
ACI 305R GUIDE TO HOT WEATHER CONCRETING
ACI 306R GUIDE TO COLD WEATHER CONCRETING
ACI 347R GUIDE TO FORMWORK FOR CONCRETE
ACI 211.1 STANDARD PRACTICE FOR SELECTING PROPORTIONS FOR NORMAL, HEAVYWEIGHT,
AND MASS CONCRETE
ACI 302.1R GUIDE TO CONCRETE FLOOR AND SLAB CONSTRUCTION
ACI 308.1 SPECIFICATION FOR CURING CONCRETE
ACI SP-4 FORMWORK FOR CONCRETE
ACI SP-66 DETAILING MANUAL
AWS D1.1 STRUCTURAL WELDING CODE - STEEL
AWS D1.3 STRUCTURAL WELDING CODE - SHEET STEEL
AWS D1.4 STRUCTURAL WELDING CODE - REINFORCING STEEL
CRSI MSP MANUAL OF STANDARD PRACTICE
CRSI 10-PLACE CRSI RECOMMENDED PRACTICE FOR "PLACING REINFORCING BARS"
USAG-KA KWAJALEIN ATOLL INSTALLATION DESIGN GUIDE
UFC 1-200-01, OCTOBER 2019 DOD BUILDING CODE
UFC 1-300-02, APRIL 2019 UNIFIED FACILITIES GUIDE SPECIFICATIONS FORMAL STANDARD
UFC 3-201-01, JULY 2019 CIVIL ENGINEERING
UFC 3-301-01, OCTOBER 2019 STRUCTURAL ENGINEERING
1. MATERIALS FOR CONCRETE AND PROPORTIONING SHALL CONFORM TO THE REQUIREMENTS OF ACI
211.1, ACI 301, AND ACI 318.
2. GENERALLY, THE AGGREGATE SIZE SHALL BE AS FOLLOWS:
3. MAXIMUM WATER/CEMENT RATIO FOR CONCRETE SHALL BE .40, UON OR APPROVED BY ENGINEER.
4. ALL CONCRETE EXPOSED TO FREEZING AND THAWING SHALL BE AIR ENTRAINED. TARGET AS
DELIVERED AIR CONTENT SHALL BE IN THE RANGE OF 5 TO 7 PERCENT.
5. CONCRETE SHALL BE PROPORTIONED AND PRODUCED TO HAVE A SLUMP OF 4 INCHES OR LESS. A
TOLERANCE OF UP TO 1 INCH ABOVE THE MAXIMUM WILL BE ALLOWED FOR ONE BATCH IN ANY FIVE
CONSECUTIVE BATCHES TESTED.
6. ADMIXTURES TO BE USED IN CONCRETE SHALL BE SUBJECT TO PRIOR APPROVAL BY THE ENGINEER.
1. ALL REINFORCING STEEL THAT IS TO BE WELDED, WHERE INDICATED ON THE CONTRACT DRAWINGS, SHALL BE DEFORMED BARS CONFORMING TO ASTM A706 AND WELDED IN ACCORDANCE WITH AWS
D1.4.
2. FIELD BENDING OF REINFORCING STEEL SHALL NOT BE DONE WITHOUT PRIOR AUTHORIZATION OF THE
CONTRACTING OFFICER
3. ALL REINFORCEMENT SHALL BE BENT COLD, UNLESS OTHERWISE PERMITTED BY THE ENGINEER.
REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT, UNLESS PERMITTED
BY THE ENGINEER IN ACCORDANCE WITH ACI 318 - SECTION 7.3.
4. REINFORCING STEEL SHALL NOT BE BENT OR DISPLACED FOR THE CONVENIENCE OF OTHER TRADES
UNLESS APPROVED BY THE STRUCTURAL ENGINEER.
5. THE PROPER TYPE AND QUANTITIES OF ACCESSORIES SHALL BE FURNISHED TO HOLD THE
REINFORCING STEEL IN PLACE WHILE THE CONCRETE IS BEING PLACED. REINFORCEMENT SHALL BE
TIED OFF AT A MINIMUM OF 50% OF THE INTERSECTIONS.
6. PRIOR TO SHIPPING OF REINFORCING STEEL TO THE FIELD, SHOP DRAWINGS SHALL BE SUPPLIED TO
THE ENGINEER FOR REVIEW.
7. REINFORCMENT SHALL BE ASTM A615 AND HAVE EPOXY COATING PER ASTM A775.
1. REFERENCE APPROVED CONTRACT DRAWINGS FOR BUILDING FOUNDATION LOCATION AND
ORIENTATIONS ON THE SITE.
2. COORDINATE OPENINGS AND EMBEDS IN CONCRETE WITH ALL OTHER TRADES.
3. NOTIFY ENGINEER OF ANY DISCREPANCIES DISCOVERED WITH OTHER TRADES.
4. ALL PLAN DIMENSIONS ARE INDICATED ON A HORIZONTAL PLANE.
1. PLACING OF CONCRETE SHALL BE IN ACCORDANCE WITH ACI 301 AND ACI 304.
2. PUMPING OR PNEUMATIC CONVEYING EQUIPMENT SHALL BE OF SUITABLE KIND WITH ADEQUATE
PUMPING CAPACITY. PNEUMATIC PLACEMENT SHALL BE CONTROLLED SO THAT SEGREGATION IS NOT
APPARENT IN THE DISCHARGED CONCRETE. THE LOSS OF SLUMP IN PUMPING OR PNEUMATIC
CONVEYING EQUIPMENT SHALL NOT EXCEED 2". CONCRETE SHALL NOT BE CONVEYED THROUGH PIPE
MADE OF ALUMINUM OR ALUMINUM ALLOY. SLUMP SPECIFIED IN CONCRETE MIX NOTE 5 SHALL BE AT
CONVEYING DISCHARGE.
3. REFER TO MECHANICAL, PIPING, ELECTRICAL & VENDOR DRAWINGS FOR NON-STRUCTURAL
EMBEDDED ITEMS.
4. ALL CONCRETE PLACED IN COLD WEATHER SHALL CONFORM TO REQUIREMENTS OF ACI 306R.
5. ALL CONCRETE PLACED IN HOT WEATHER SHALL CONFORM TO REQUIREMENTS OF ACI 305R.
6. CONCRETE CURING IS REQUIRED FOR ALL EXPOSED SURFACES. CONCRETE SURFACES SHALL BE
KEPT AT MOIST CONDITION FOR AT LEAST 7 DAYS. ALTERNATIVELY, MEMBRANE TYPE OF CURING
COMPOUND MAY BE USED. MASS CONCRETE SHALL BE CURED IN ACCORDANCE WITH ACI 301.
1. FORMWORK SHALL BE IN ACCORDANCE WITH ACI 301 AND ACI 347R.
2. ACI SPECIAL PUBLICATION 4 SHALL BE USED AS A GUIDE.
3. WHERE WOOD FORMS ARE USED, THEY SHALL BE PLY FORM OR GRADED EXTERIOR TYPE PLYWOOD, GRADE BB OR BETTER.
4. FORMS OR SHORES SHALL NOT BE REMOVED WITHOUT THE APPROVAL OF THE CONSTRUCTION
MANAGER. ALL REMOVAL SHALL BE ACCOMPLISHED IN A MANNER TO PREVENT INJURY TO THE
CONCRETE. FORMS SHALL GENERALLY NOT BE REMOVED PRIOR TO THE MINIMUM NUMBER OF DAYS
INDICATED BELOW:
SLABS AND BEAM BOTTOMS - 14 DAYS
WALLS AND FOOTINGS - 3 DAYS
COLUMNS - 3 DAYS
STRUCTURES SHALL NOT BE LOADED UNTIL CONCRETE HAS CURED TO A
MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI.
1. HEADED SHEAR STUDS SHALL BE NELSON HEADED ANCHORS WITH FLUXED ENDS OR APPROVED
EQUAL. DEFORMED BAR ANCHORS (DBA) SHALL BE NELSON, TYPE D2L, OR APPROVED EQUAL. STUDS
AND DBA SHALL BE AUTOMATICALLY END-WELDED WITH MANUFACTURER'S STANDARD EQUIPMENT
AND SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
2. PERMANENTLY EXPOSED EMBEDDED PLATES AND ANGLES SHALL BE 316 STAINLESS STEEL UON.
3. WATERSTOPS SHALL BE PVC WATERSTOPS CONFORMING TO CRD-C-572 AND SHALL BE OF THE SIZES
INDICATED. WATERSTOPS FOR CONSTRUCTION JOINTS SHALL BE THREE-EIGHTH-INCH THICK,
"DUMBBELL" STYLE. WATERSTOPS FOR EXPANSION JOINT SHALL BE THREE-EIGHTH-INCH THICK, "CENTER BULB" STYLE. "SPLIT FLANGE" WATERSTOPS, THREE-EIGHTH-INCH THICK, SHALL BE
INSTALLED AS INDICATED OR REQUIRED FOR THE WORK AND APPROVED BY ENGINEER. PVC
WATERSTOPS SHALL BE THE PRODUCT OF GREENSTREAK, INC.,W.R.MEADOWS, INC. OR SIKA
CORPORATION, UNLESS OTHERWISE APPROVED BY ENGINEER.
1. ALL ANCHOR BOLTS AND EMBEDDED STRUCTURAL ANCHORAGES AND SUPPORTS SHALL BE SUPPLIED
AND INSTALLED BY THE CONCRETE CONTRACTOR, UNLESS OTHERWISE SPECIFIED.
2. ALL ANCHOR BOLTS SHALL BE SET AND PLUMBED WITH TEMPLATES. ALL EMBEDDED ITEMS SHALL BE
ACCURATELY SECURED IN PLACE.
1. AFTER THE REMOVAL OF FORMS, SURFACES OF CONCRETE SHALL BE FINISHED IN ACCORDANCE WITH
THE REQUIREMENTS OF ACI 301, UON. NO SURFACE MOCK-UPS ARE REQUIRED UON.
2. SURFACE DEFECTS AND TIE HOLES SHALL BE REPAIRED IN ACCORDANCE WITH THE REQUIREMENTS
OF ACI 301.
3. UNLESS STAINLESS STEEL, NONCORROSIVE, OR COATED TIES ARE USED, TIE HOLES IN SURFACES NOT
TO BE EXPOSED IN THE FINISHED WORK SHALL BE CLEANED, THOROUGHLY DAMPENED, AND FILLED
SOLID WITH PATCHING MORTAR.
1. FLOOR FINISHES AS SPECIFIED ON PLANS SHALL COMPLY WITH ACI 301 REQUIREMENTS FOR FINISHING
UNFORMED SURFACES.
2. FLOOR SURFACE CLASSIFICATIONS AS SPECIFIED ON PLANS SHALL COMPLY WITH ACI 117 FLOOR
FINISH TOLERANCE REQUIREMENTS.
3. WHERE FLOOR FINISHES AND SURFACE CLASSIFICATIONS HAVE NOT BEEN SPECIFIED ON PLANS, THE
FOLLOWING ACI 301 FLOOR SURFACE FINISHES AND ACI 117 FLOOR SURFACE CLASSIFICATIONS SHALL
APPLY:
A. SURFACES TO RECEIVE BONDED APPLIED CEMENTITIOUS APPLICATIONS SHALL RECEIVE A
SCRATCHED FINISH. FLOOR SURFACE TOLERANCES SHALL COMPLY WITH ACI 117 REQUIREMENTS
FOR A CONVENTIONAL FLOOR SURFACE CLASSIFICATION.
B. EXTERIOR BUILDING ENTRANCES; EXPOSED CONCRETE FLOORS OF VESTIBULES, PLATFORMS, RAMPS, LOADING DOCKS; MAIN ENTRANCE AISLES OF WAREHOUSES OR STORAGE AREAS; INTERIOR
TRAFFIC AISLES SUBJECT TO MOTORIZED TRAFFIC, AS INDICATED ON THE CONTRACT DRAWINGS;
AND, CONCRETE STAIR TREADS AND LANDINGS SHALL RECEIVE A NONSLIP FINISH. FLOOR
SURFACE TOLERANCE SHALL COMPLY WITH ACI 117 REQUIREMENTS FOR A MODERATELY FLAT
FLOOR SURFACE CLASSIFICATION.
C. ALL OTHER SIDEWALKS, AND FLOORS AND RAMPS SUBJECT TO VEHICULAR TRAFFIC, SHALL
RECEIVE A BROOM FINISH. FLOOR SURFACE TOLERANCE SHALL COMPLY WITH ACI 117
REQUIREMENTS FOR A MODERATELY FLAT FLOOR SURFACE CLASSIFICATION.
4. RANDOM TRAFFIC FLOOR FINISH TOLERANCES SHALL BE MEASURED IN ACCORDANCE WITH ASTM
E1155 OR BY THE MANUAL STRAIGHTEDGE APPROACH DETAILED BY ACI 117.
REFERENCE ASTM C33 FOR GRADATION. PROPORTIONS OF AGGREGATE TO CEMENT FOR ANY CONCRETE
MIX SHALL BE SUCH AS TO PRODUCE A MIXTURE WHICH, CONSISTENT WITH THE METHOD OF PLACING, WILL WORK READILY INTO CORNERS AND ANGLES OF THE FORMS AND AROUND REINFORCEMENT
WITHOUT PERMITTING THE MATERIALS TO SEGREGATE OR EXCESS WATER TO COLLECT ON THE SURFACE.
VERIFICATION AND INSPECTION TASK CONTINUOUS PERIODIC
-- X
REFERENCED STANDARD IBC REFERENCE
X
-- X
X --
-- X
-- X
X --
ACI 318: CH 20, 25.2, 25.3, 26.5.1 TO 26.5.3
ACI 318: 26.5.4
ACI 318: CH 19, 26.4.3, 26.4.4
ACI 318: 17.8.2
ASTM C172
ASTM C31
ACI 318: 26.4.5, 26.12
ACI 318: 26.4.5
ACI 318: 26.4.7-26.4.9
1908.4
1908.9
1904.1, 1904.2, 1908.2, 1908.3
1908.10
1908.6, 1908.7, 1908.8
LIST OF TESTS AND SPECIAL INSPECTIONS
IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE (IBC) 2018, SECTION 1705.3 AND UFC-200-01 PARAGRAPH 2-17.2, THE FOLLOWING MEANS
AND METHODS OF CONSTRUCTION ARE SUBJECT TO SPECIAL INSPECTIONS:
INSPECTION OF ANCHORS POST-INSTALLED IN HARDENED
CONCRETE MEMBERS. (SEE THE ANCHOR RESEARCH REPORT
FOR SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION)
INSPECTION OF REINFORCING STEEL, INCLUDING
PRESTRESSING TENDONS, AND PLACEMENT
INSPECTION OF ANCHORS CAST IN CONCRETE WHERE
ALLOWABLE LOADS HAVE BEEN INCREASED OR WHERE
STRENGTH DESIGN IS USED
VERIFYING USE OF REQUIRED DESIGN MIX
AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE
SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND
AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF
THE CONCRETE
INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR
PROPER APPLICATION TECHNIQUES
INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES
GENERAL CONCRETE NOTES
FORMED SURFACES
TABLE 1
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
SHEET ID
US Army Corps of Engineers
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
S-002
G E
N E
R A
L
C
O N
C R
E T
E
N
O T
E S
P
S
T E
N B
E R
G
J
T
U R
N E
R
C
W
E B
S T
E R
S
C
R E
A
R T
A
D
E S
I G
N
S
U B
M I T
T A
L
D I S
T R
I B
U T
I O
N
O
P T
I O
D
I F
I C
A T
I O
N S
S E
P
J A
N
RTA (100%) DESIGN SUBMITTAL
M E
L A
N D
U
S
A
R M
Y
G
A R
R I S
W A
J A
L E
O
S A
G K
A
C O
N T
A I N
E R
I Z
W
R
A
E
C T
R I C
S
T R
I B
U T
I O
N
F Y
S
M
I S
S I L
E
D
E F
E N
E
N C
Y
R E
P U
B L
T
H
R
S H
A L
L
I S
L A
N D
S
H O
N O
L U
S
T R
I C
T
B L
E C
T P
O H
F T
S
H A
F T
E R
H
I
S E
P
W
A
D
A N
S I
D
1/27/22
Phillip Stenberg
Digitally signed by Phillip Stenberg
DN: C=US,
E=phil.stenberg@powereng.com, O="POWER Engineers, Inc", CN=Phillip Stenberg Location: Meridian, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info:
phil.stenberg@powereng.com Date: 2020.09.01 21:36:20-06'00'
Phillip Stenberg
Digitally signed by Phillip Stenberg
DN: C=US,
E=phil.stenberg@powereng.com, O="POWER Engineers, Inc", CN=Phillip Stenberg Location: Meridian, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info:
phil.stenberg@powereng.com Date: 2020.09.01 21:37:01-06'00'
F-001
FI
R
E
PR
O
TE
C
TI
O N
N O
TE
S, S
YM
BO
LS
AN
D
A
BB
R
EV
IA
TI
O N
S
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
J.
T.
H
IG
AS
H
I
K.
L.
M C
KE
E
R .T
. B
IG
TA
S
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N , K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SL
E D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
1. THE SPRINKLER SYSTEM DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 13-2019, AND SPECIFICATION SECTION 21 13 13.00 10. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL SPRINKLER SYSTEM COMPONENTS AND COORDINATE WITH THE VARIOUS TRADES. DESIGN AND INSTALLATION SHALL MEET UFC 3-600-01.
2. ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM APPROVED.
3. AUTOMATIC SPRINKLER PROTECTION SHALL BE PROVIDED THROUGHOUT THE BUILDING.
4. WATER SUPPLY INFORMATION: DATA WAS PROVIDED BY NAVFAC. TEST CONDUCTED BY COFFMAN ENGINEERS ON
SEPTEMBER 19, 2019:
STATIC PRESSURE: 125 PSI
RESIDUAL PRESSURE: 20 PSI
FLOW AT RESIDUAL PRESSURE: 3,476 GPM
5. THE SPRINKLER SYSTEM SHALL BE HYDRAULICALLY DESIGNED IN ACCORDANCE WITH NFPA 13. SPRINKLER SYSTEM
DESIGN CRITERIA SHALL BE AS FOLLOWS:
WET PIPE SYSTEMS
POWER DISTRIBUTION CENTER (PDC)
OCCUPANCY HAZARD CLASSIFICATION: ORDINARY HAZARD
DESIGN DENSITY: 0.20 GPM/SF
DESIGN AREA: 2,500 SF
SPRINKLER TYPE: K - 8.0, QUICK RESPONSE TYPE
SPRINKLER TEMPERATURE: ORDINARY TEMPERATURE
HOSE STREAM: 250 GPM
6. SPRINKLERS SHALL BE LOCATED IN THE CENTER OF CEILING TILES WHERE APPLICABLE.
7. SPRINKLER PIPING SHALL COMPLY WITH NFPA 13, EXCEPT THAT COPPER AND PLASTIC PIPE SHALL NOT BE PERMITTED. FLEXIBLE HOSE SPRINKLERS SHALL NOT BE PERMITTED. ALL PIPING AND FITTINGS SHALL BE PAINTED.
ALL PIPING ON THE WET PIPE SYSTEM SHALL BE SCHEDULE 40 BLACK STEEL.
8. THE PIPE ROUTING AND SPRINKLER LOCATIONS ARE CONCEPTUAL. THE CONTRACTOR SHALL INSTALL THE SYSTEM IN ACCORDANCE WITH THE APPLICABLE CODES, MANUFACTURER'S RECOMMENDATIONS AND EQUIPMENT LISTINGS.
9. PIPING SHALL BE PROVIDED WITH EARTHQUAKE PROTECTION IN ACCORDANCE WITH NFPA 13 AND SPECIFICATION
SECTION 21 13 13.00 10. PROVIDE BRANCH LINE RESTRAINTS.
10. SPRINKLERS IN THE POWER DISTRIBUTION CENTER SHALL BE ELECTROLESS NICKEL FINISH.
11. PROVIDE A PRESSURE RELIEF VALVE AT THE FIRE SPRINKLER RISER IN ACCORDANCE WITH NFPA 13.
12. PROVIDE MAINS AND BRANCHLINES IN THE FACILITY TO LIMIT THE VELOCITIES IN THE OVERHEAD PIPING TO LESS
THAN 20 FT/SEC.
13. SPARE SPRINKLERS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13. HYDRAULIC DATA PLATES SHALL BE
PROVIDED AT EACH RISER.
1. THE FIRE ALARM SYSTEM SHALL BE DESIGNED AND INSTALLED
IN ACCORDANCE WITH NFPA 72-2019 AND SPECIFICATION SECTION 28 31 64.00 10
2. ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM APPROVED.
3. DEVICE LOCATIONS ARE CONCEPTUAL. FINAL QUANTITY AND LAYOUT SHALL BE IN
ACCORDANCE WITH APPLICABLE CODES, MANUFACTURER'S RECOMMENDATION, AND
EQUIPMENT LISTINGS. COORDINATE LOCATIONS WITH CEILING AND BELOW FLOOR
ELECTRICAL INSTALLATION.
4. ALL FIRE ALARM CONDUIT SHALL BE 3/4-IN MINIMUM. ALL CONDUIT IN FINISHED AREAS
SHALL BE CONCEALED.
5. SYNCHRONIZE ALL VISUAL NOTIFICATION APPLIANCES. SYNCHRONIZE ALL AUDIBLE
NOTIFICATION APPLIANCES.
6. THE FIRE ALARM SIGNAL SHALL BE A TEMPORAL THREE TONE.
7. VISUAL NOTIFICATION APPLIANCES SHALL BE SPACED IN ACCORDANCE WITH NFPA 72.
8. SIGNALING LINE CIRCUITS SHALL BE CLASS B, INITIATING DEVICE CIRCUITS SHALL BE
CLASS B, NOTIFICATION APPLIANCE CIRCUITS SHALL BE CLASS B.
9. SMOKE DETECTORS SHALL BE LOCATED A MINIMUM OF 5 FEET FROM SUPPLY AND
RETURN AIR DIFFUSERS.
10. PROVIDE SIGNAGE AT THE FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
IDENTIFYING THE POWER PANEL AND CIRCUIT.
11.
12.
13.
ALL CIRCUITS MUST BE PULLED FROM DEVICE TO DEVICE. NO SPLICES OR T-TAPPING
IS ALLOWED.
FIRE ALARM VISUAL DEVICES SHALL BE WHITE AND MARKED "ALERT" WITH CLEAR LENSES.
PAINTING SHALL COMPLY WITH SPECIFICATION SECTIONS 09 90 00 AND 28 31 64.00 10.
PENDENT SPRINKLER
UPRIGHT SPRINKLER
DESCRIPTION
OS&Y VALVE
CHECK VALVE
NEW
WET PIPE FIRE SPRINKLER RISER
TAMPER SWITCH
FIRE DEPARTMENT CONNECTION
ABOVE FINISH FLOORAFF
PIPE BREAK FOR CONTINUATION OR CLARITY
PIPE UP, AS NOTED
PIPE DOWN, AS NOTED
FDC FIRE DEPARTMENT CONNECTION
(TYP) TYPICAL
PIPE CAPPED FOR FUTURE USE
WET PIPE FIRE SPRINKLER PIPING
FLOW SWITCH
FIRE SPRINKLER SYSTEM LEGEND
DRAIN PIPED
SIDEWALL MOUNTED SPRINKLER
VS
WF
AHU AIR HANDLING UNITS
OS&Y OUTSIDE SCREW AND YOKE
FACP
FEP
DESCRIPTION
MANUAL DOUBLE-ACTION PULL STATION
SYMBOL
FIRE ALARM/MASS NOTIFICATION SYSTEM CONTROL PANEL
WALL MOUNTED FIRE NOTIFICATION APPLIANCE
ABOVE FINISH FLOORAFF
PHOTOELECTRIC SYSTEM SMOKE DETECTOR
WP WEATHERPROOF
TYP TYPICAL
BOOSTER POWER SUPPLY
FIRE ALARM / MASS NOTIFICATION SYMBOLS AND ABBREVIATIONS
F
PS
FIRE SPRINKLER SYSTEM NOTES:FIRE ALARM NOTES:
07/22/2019 Expiration Date of the License
07/22/2021 Jay T Higashi
Digitally signed by Jay T Higashi
DN: C=US,
E=jay.higashi@coffman.com, O=Coffman Engineers, OU=Fire Protection Engineering, CN=Jay T Higashi Date: 2020.09.02 13:04:04-10'00'
POWER
DISTRIBUTION
CENTER
S
FX101
EL
EC
TR
IC
AL
P
O W
ER
D
IS
TR
IB
U
TI
O
N C
EN
TE
R
FI
R E
SP
R
IN
KL
ER
L
AY
O
U T
1. REFER TO DRAWING F-001 FOR GENERAL NOTES, LEGEND, AND
ABBREVIATIONS.
GENERAL NOTES: THIS SHEET ONLY
2 0 2 4FTSCALE: 3/8"=1-0"
A4
POWER DISTRIBUTION CENTER
FIRE SPRINKLER LAYOUT
NORTH
PLAN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
J.
T.
H
IG
AS
H
I
K.
L.
M C
KE
E
R .T
. B
IG
TA
S
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N , K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SL
E D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
1. 2.5 INCH FIRE SPRINKLER RISER WITH BACKFLOW PREVENTER
2. VERTICAL BACKFLOW TEST HEADER
3. FIRE DEPARTMENT CONNECTION
4. SEE CIVIL DRAWINGS FOR CONTINUATION
5. 1 INCH BRANCH LINE (TYPICAL)
6. 2 INCH MAIN (TYPICAL)
7. TRANSITION FROM 6 INCH UNDERGROUND TO 2.5 INCH RISER INSIDE THE
BUILDING. SEE SHEET FX501 FOR MORE INFORMATION.
SHEET KEYNOTES
07/22/2019 Expiration Date of the License
07/22/2021 Jay T Higashi
Digitally signed by Jay T Higashi
DN: C=US,
E=jay.higashi@coffman.com, O=Coffman Engineers, OU=Fire Protection Engineering, CN=Jay T
Date: 2020.09.02 13:04:42-10'00'
FX501
EL
EC
TR
IC
AL
P
O W
ER
D
IS
TR
IB
U
TI
O
N C
EN
TE
R
FI
R E
SP
R
IN
KL
ER
D
ET
AI
LS
1. REFER TO DRAWING F-001 FOR GENERAL NOTES, LEGEND, AND
ABBREVIATIONS.
GENERAL NOTES: THIS SHEET ONLY
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
J.
T.
H
IG
AS
H
I
K.
L.
M C
KE
E
R .T
. B
IG
TA
S
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N , K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SL
E D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
STEEL
SWAY BRACE
FITTINGS
SCHEDULE 40
PIPE *
PIPE CLAMP
SPRINKLER
CROSSMAIN
* PIPE SIZES SHALL BE DETERMINED BY CALCULATIONS.
SWAY BRACE
FITTINGS
SCHEDULE 40
PIPE *
SPRINKLER CROSS
MAIN
PIPE CLAMP
STEEL
* PIPE SIZES SHALL BE DETERMINED BY CALCULATIONS.
ALL THREAD ROD
(TYP) *
END OF BRANCH
LINE SURGE
RETAINER CLIP
ADJUSTABLE RING
HANGER
ROD COUPLING
PURLINBOLT
* THREADED ROD SIZE AND LENGTH SHALL BE DETERMINED BY
CALCULATIONS IN ACCORDANCE WITH NFPA 13, PARAGRAPH
18.6.1. WHERE L/R DOES NOT EXCEED 400 FOLLOW THE
GUIDANCE OF 18.6.1 (5).
"A
PROVIDE A SECOND
RESTRAINT IN THE
OPPOSITE DIRECTION
WHEN "A" IS GREATER
THAN 29"
SCALE: NTS
A1
LONGITUDINAL SWAY BRACE DETAIL
SCALE: NTS
A5
TYPICAL END-HEAD RESTRAINT DETAIL
SCALE: NTS
D6
LATERAL SWAY BRACE DETAIL
SCALE: NTS
D3
FIRE SPRINKLER RISER DETAIL
AUTO SPKR
TEST HEADER
VS
VS
ALARM PRESSURE SWITCH
RETARD CHAMBER
PRESSURE GAUGES
2" DRAIN, TERMINATE 6" ABOVE SPLASH
BLOCK
WATER MOTOR GONG MOUNTED ON
EXTERIOR OF BUILDING
CHECK VALVE
1 - 2 1/2" FIRE DEPARTMENT CONN. 2'-6"
ABOVE GRADE, LOCATED ON THE
BUILDING EXTERIOR
1 - 2 1/2" TEST HEADER CONN. 2'-6"
ABOVE GRADE, LOCATED ON THE
BUILDING EXTERIOR
SPLASH BLOCK, INSPECTORS TEST
CONNECTION SHALL TERMINATE
OUTSIDE THE BUILDING
CONCRETE THRUST BLOCK AT BASE
OF RISER 10.0 SF MINIMUM OF BEARING
SURFACE
2 1/2" OS&Y VALVE WITH LOCK
AND CHAIN
PROVIDE 4-WAY SWAY BRACING AT TOP AND BOTTOM OF
RISER
ALARM CHECK VALVE, ALL ALARM AND TEST BALL
VALVES SHALL BE PROVIDED WITH A TAMPER
SWITCH
FLEXIBLE COUPLING WITHIN 24" OF TOP AND BOTTOM OF
THE RISER (TYP)
DRAIN LINE (DRAIN SHALL NOT BE CONNECTED TO
THE MAIN DRAIN)
2 1/2" DOUBLE CHECK VALVE
BACKFLOW ASSEMBLY
OS&Y CONTROL VALVE W/TAMPER SWITCH (TYP.)
* NOTE: ENGINEER SHALL REVIEW LOCATION OF 4-WAY BRACE IN
REFERENCE TO FLEX COUPLING LOCATION
6" UNDER GROUND WATER SUPPLY, SEE CIVIL
DRAWINGS FOR CONTINUATION
3/4" STAINLESS STEEL TIE
RODS, BITUMASTIC COATED
1" PRESSURE RELIEF
VALVE SET AT 175 PSI
PS
VS
PROVIDE PIPE SUPPORT
PER NFPA 13
TRANSITION FROM PVC TO
STEEL AT THIS FITTING
TRANSITION FROM 6"
INCOMING TO 2 1/2 " RISER
07/22/2019 Expiration Date of the License
07/22/2021 Jay T Higashi
Digitally signed by Jay T Higashi
DN: C=US,
E=jay.higashi@coffman.com, O=Coffman Engineers, OU=Fire Protection Engineering, CN=Jay T
Date: 2020.09.02 13:05:11-10'00'
POWER
DISTRIBUTION
CENTER
S
F F
S P
FACP
S P S P
S P
WF
VS
VS
VS
FA101
EL
EC
TR
IC
AL
P
O W
ER
D
IS
TR
IB
U
TI
O
N C
EN
TE
R
FI
R E
AL
AR
M L
AY
O
U T
1. REFER TO DRAWING F-001 FOR GENERAL NOTES, LEGEND, AND
ABBREVIATIONS.
GENERAL NOTES: THIS SHEET ONLY
2 0 2 4FTSCALE: 3/8"=1-0"
A4
POWER DISTRIBUTION CENTER
FIRE ALARM LAYOUT
NORTH
PLAN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
J.
T.
H
IG
AS
H
I
K.
L.
M C
KE
E
R .T
. B
IG
TA
S
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N , K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SL
E D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
1. FIRE ALARM CONTROL PANEL
2. POTS LINE TO FIRE DEPARTMENT POINT OF CONNECTION
SHEET KEYNOTES
07/22/2019 Expiration Date of the License
07/22/2021 Jay T Higashi
Digitally signed by Jay T Higashi
DN: C=US,
E=jay.higashi@coffman.com, O=Coffman Engineers, OU=Fire Protection Engineering, CN=Jay T
Date: 2020.09.02 13:05:41-10'00'
FACP
TVSS
S P
SEE ELECTRICAL DRAWINGS
FOR CONTINUATION
1P,20A
75 15
FFIRE ALARM POTS LINE
TO FIRE DEPARTMENT
CONNECTION
F S P
S P
S P
WF VS VS VS
FA501
EL
EC
TR
IC
AL
P
O W
ER
D
IS
TR
IB
U
TI
O
N C
EN
TE
R
FI
R E
AL
AR
M D
ET
AI
LS
, S
EQ
U
EN
C
E
AN
D R
IS
ER
D
IA
G R
AM
1. REFER TO DRAWING F-001 FOR GENERAL NOTES, LEGEND, AND
ABBREVIATIONS.
GENERAL NOTES: THIS SHEET ONLY
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
J.
T.
H
IG
AS
H
I
K.
L.
M C
KE
E
R .T
. B
IG
TA
S
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N , K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SL
E D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
SCALE: NTS
A2
FIRE PROTECTION RISER DIAGRAM
ALERT
VISUAL OR AUDIO/
VISUAL DEVICE
MANUAL FIRE
ALARM PULL
STATION
FIRE
AUDIO DEVICE
7' -6
6' -8
4' -0
5'-0" MAX.
* IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR AUDIO DEVICES WHILE LEAVING A MINIMUM OF 6-INCHES BETWEEN THE CEILING AND THE TOP OF THE AUDIO DEVICE, THE DEVICE SHALL BE MOUNTED AT 6-INCHES BELOW CEILING MEASURED TO THE TOP OF THE DEVICE.
** IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR VISUAL OR AUDIO/ VISUAL DEVICES WHILE LEAVING A MINIMUM OF 6-INCHES BETWEEN THE CEILING AND THE TOP OF THE VISUAL OR AUDIO/ VISUAL DEVICE, THE DEVICE SHALL BE MOUNTED AT 6-INCHES BELOW CEILING
MEASURED TO THE TOP OF THE DEVICE.
SCALE: NTS
D1
TYPICAL MOUNTING DETAIL FOR FIRE ALARM
DEVICES
07/22/2019 Expiration Date of the License
07/22/2021 Jay T Higashi
Digitally signed by Jay T Higashi
DN: C=US,
E=jay.higashi@coffman.com, O=Coffman Engineers, OU=Fire Protection Engineering, CN=Jay T
Date: 2020.09.02 13:06:04-10'00'
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
XE001
D
IS
TR
IB
U
TI
O N
S H
EE
T
LA
YO
U T
AN
D
V
IC
IN
IT
Y M
AP
S.
A
R N
O
LD
G . S
IZ
EM
O R
E
C . S
TO
C
KL
IN
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SI
LE
D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
A1
DISTRIBUTION VICINITY MAP
TRUE N
SCALE NTS
E1 SCALE NTS
TRUE N
5017 5040
5115 5118 5119
5092 5095
NORTH
PLAN
PDC
SECTIONALIZER S1
SECTIONALIZERS
S2, S3, S4
SECTIONALIZERS
S5, S6
FUTURE B5098
UNIT SUB
SECTIONALIZERS
S7, S8
SECTIONALIZERS
S9, S10
SECTIONALIZERS
S11, S12
TECH 1 & 2
UNIT SUB
Clay J. Stocklin
Digitally signed by Clay J. Stocklin
DN: C=US,
E=clay.stocklin@powereng.com, O="POWER Engineers, Inc.", OU=Distribution Services Dept I, CN=Clay J. Stocklin Location: Hailey, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info:
clay.stocklin@powereng.com Date: 2020.09.02 12:46:25-06'00'
2020 10 0 40FTSCALE: 1"=20'
D1
PLAN VIEW - AREA UTILITY
NORTH
PLAN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
XE101
PL
AN
A N
D P
R O
FI
LE
AR
EA
U
TI
LI
TY
SH
EE
T
O F
S.
A
R N
O
LD
G . S
IZ
EM
O R
E
C . S
TO
C
KL
IN
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SI
LE
D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
GENERAL NOTES: THIS SHEET ONLY
1. THE UTILITIES AND NATURAL FEATURES SHOWN HEREON ARE BASED ON
FIELD SURVEYS, AERIAL PHOTOGRAPHY AND RECORD DOCUMENTS. OTHER
FACILITIES MAY EXIST NOT DISCOVERED THROUGH THE RECORD CHECK.
THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION, BOTH HORIZONTAL
AND VERTICAL, OF ALL UTILITIES.
2. CONTROL POINTS AND TOPOGRAPHY ARE TAKEN FROM SURVEY
INFORMATION RECEIVED FROM CONTROLPOINT SURVEYING, INC. 615 PIIKOI
STREET, SUITE 700 HONOLULU, HAWAII 96814, DATED ON DECEMBER 03, 2019
WITH FILE NAME : 16091-01 AEC_FINAL.DWG
3. FOR PLANT COORDINATES REFER TO :
VERTICAL DATUM
"FELIPE" BRASS DISK
N 3269789.30 E 2624088.52
EL 43.38 MSL (US FT)
HORIZONTAL DATUM
UTM 58 NORTH
4. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RETURNED TO THE
ORIGINAL CONDITION OR BETTER AS DETERMINED BY GOVERNMENT.
5. ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CONTRACT SPECIFICATIONS OR APPROPRIATE
INDUSTRY STANDARDS WHERE INDICATED.
6. THE CONTRACTOR SHALL VERIFY AND CHECK ALL DIMENSIONS AND DETAILS
ON THE DRAWINGS BEFORE PROCEEDING WITH THE WORK. ANY
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER FOR CLARIFICATION PRIOR TO THE FABRICATION
AND /OR ORDERING OF MATERIAL.
7. RESTORATION OF ROADS AND ALL OTHER IMPROVEMENTS, UNAVOIDABLY
DAMAGED SHALL BE REPAIRED AND COST BORNE BY THE CONTRACTOR.
8. THE CONTRACTOR SHALL BE REQUIRED TO PROVIDE ADEQUATE, SAFE,
NON-SKID BRIDGING MATERIAL OVER THE TRENCH, INCLUDING SHORING,
WHEN TRENCHING IN ROAD AREAS TO HANDLE ALL TYPES OF VEHICULAR
TRAFFIC.
9. WHEN EXCAVATION IS ADJACENT TO OR UNDER EXISTING STRUCTURES OR
FACILITIES, THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SHEETING
AND BRACING THE EXCAVATION AND STABILIZING THE EXISTING GROUND TO
RENDER IT SAFE AND SECURE FROM POSSIBLE SLIDES, CAVE-INS, AND
SETTLEMENTS, AND FOR PROPERLY SUPPORTING EXISTING STRUCTURES
AND FACILITIES WITH BEAMS, STRUTS OR UNDERPINNING TO FULLY
PROTECT IT FROM DAMAGE.
10. ALL MATERIALS FOR THIS PROJECT SHALL BE NEW AND FREE FROM ANY AND
ALL DEFECTS UNLESS SPECIFIED OTHERWISE.
11. DUCT BANK SHALL MAINTAIN A MINIMUM COVER DEPTH OF 2'-0" BELOW
GRADE.
12. DUCT BANK SHALL MAINTAIN MINIMUM HORIZONTAL CLEARANCE OF 1'-0" AND
A MINIMUM VERTICAL CLEARANCE OF 1'-0" OVER OR UNDER EXISTING
UTILITIES, UNLESS OTHERWISE SHOWN ON DRAWINGS.
13. TERMINATE AND CAP SPARE CONDUIT IN SECTIONALIZING CABINET.
2020 10 0 40FTSCALE: 1"=20'
A1
PROFILE VIEW - AREA UTILITY
2 1 0 2 4FT
HORIZONTAL SCALE 1"= 20' VERTICAL SCALE 1"= 2'
XE
A1
TR
U
E N
XE102
D1
INTERCEPT EXISTING MV
CABLE TO FIRE STATION
AND TERMINATE IN NEW
SECTIONALIZER
LEGEND
- PROPOSED SECTIONALIZER
- PROPOSED UNDERGROUND CABLE ROUTING
- PROPOSED DUCTBANK
AREA UTILITY
S1
05 5 10FTSCALE: 1"=5'
E7
ENLARGED PLAN VIEW AT
SECTIONALIZER
TO FIRE
STATION
TO AREA
UTILITY
TO AREA
UTILITY
SEE NOTE 13
SECTIONALIZER S1
A1
XE301
A1
XE301
A1
XE501
E1
XE202
FRONT
Clay J. Stocklin
Digitally signed by Clay J.
Stocklin
DN: C=US,
E=clay.stocklin@powereng.com, O="POWER Engineers, Inc.", OU=Distribution Services Dept I, CN=Clay J. Stocklin Location: Hailey, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info:
Date: 2020.09.02 12:46:34-06'00'
NORTH
PLAN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
XE102
PL
AN
A N
D P
R O
FI
LE
AR
EA
U
TI
LI
TY
SH
EE
T
O F
S.
A
R N
O
LD
G . S
IZ
EM
O R
E
C . S
TO
C
KL
IN
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SI
LE
D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
2020 10 0 40FTSCALE: 1"=20'
D2
PLAN VIEW - AREA UTILITY
2020 10 0 40FTSCALE: 1"=20'
A1
PROFILE VIEW - AREA UTILITY
HORIZONTAL SCALE 1"= 20'
TR
U
E N
XE
A1
XE101
D1
GENERAL NOTES: THIS SHEET ONLY
1. THE UTILITIES AND NATURAL FEATURES SHOWN HEREON ARE BASED ON
FIELD SURVEYS, AERIAL PHOTOGRAPHY AND RECORD DOCUMENTS. OTHER
FACILITIES MAY EXIST NOT DISCOVERED THROUGH THE RECORD CHECK.
THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION, BOTH HORIZONTAL
AND VERTICAL, OF ALL UTILITIES.
2. CONTROL POINTS AND TOPOGRAPHY ARE TAKEN FROM SURVEY
INFORMATION RECEIVED FROM CONTROLPOINT SURVEYING, INC. 615 PIIKOI
STREET, SUITE 700 HONOLULU, HAWAII 96814, DATED ON DECEMBER 03, 2019
WITH FILE NAME : 16091-01 AEC_FINAL.DWG
3. FOR PLANT COORDINATES REFER TO :
VERTICAL DATUM
"FELIPE" BRASS DISK
N 3269789.30 E 2624088.52
EL 43.38 MSL (US FT)
HORIZONTAL DATUM
UTM 58 NORTH
4. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RETURNED TO THE
ORIGINAL CONDITION OR BETTER AS DETERMINED BY GOVERNMENT.
5. ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CONTRACT SPECIFICATIONS OR APPROPRIATE
INDUSTRY STANDARDS WHERE INDICATED.
6. THE CONTRACTOR SHALL VERIFY AND CHECK ALL DIMENSIONS AND DETAILS
ON THE DRAWINGS BEFORE PROCEEDING WITH THE WORK. ANY
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER FOR CLARIFICATION PRIOR TO THE FABRICATION
AND /OR ORDERING OF MATERIAL.
7. RESTORATION OF ROADS AND ALL OTHER IMPROVEMENTS, UNAVOIDABLY
DAMAGED SHALL BE REPAIRED AND COST BORNE BY THE CONTRACTOR.
8. THE CONTRACTOR SHALL BE REQUIRED TO PROVIDE ADEQUATE, SAFE,
NON-SKID BRIDGING MATERIAL OVER THE TRENCH, INCLUDING SHORING,
WHEN TRENCHING IN ROAD AREAS TO HANDLE ALL TYPES OF VEHICULAR
TRAFFIC.
9. WHEN EXCAVATION IS ADJACENT TO OR UNDER EXISTING STRUCTURES OR
FACILITIES, THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SHEETING
AND BRACING THE EXCAVATION AND STABILIZING THE EXISTING GROUND TO
RENDER IT SAFE AND SECURE FROM POSSIBLE SLIDES, CAVE-INS, AND
SETTLEMENTS, AND FOR PROPERLY SUPPORTING EXISTING STRUCTURES
AND FACILITIES WITH BEAMS, STRUTS OR UNDERPINNING TO FULLY
PROTECT IT FROM DAMAGE.
10. ALL MATERIALS FOR THIS PROJECT SHALL BE NEW AND FREE FROM ANY AND
ALL DEFECTS UNLESS SPECIFIED OTHERWISE.
11. DUCT BANK SHALL MAINTAIN A MINIMUM COVER DEPTH OF 2'-0" BELOW
GRADE.
12. DUCT BANK SHALL MAINTAIN MINIMUM HORIZONTAL CLEARANCE OF 1'-0" AND
A MINIMUM VERTICAL CLEARANCE OF 1'-0" OVER OR UNDER EXISTING
UTILITIES, UNLESS OTHERWISE SHOWN ON DRAWINGS.
13. INSTALL A MINIMUM OF FIVE BOLLARDS, CONTRACTOR TO VERIFY ADEQUATE
PROTECTION FOR ABOVE GROUND EQUIPMENT.
14. TERMINATE AND CAP SPARE CONDUIT IN TECH 1 SECTIONALIZING CABINET.
15. TERMINATE AND CAP SPARE CONDUIT IN TECH 1 SWITCHGEAR CUBICLE.
16. DO NOT INSTALL 4" COMMUNICATION CONDUIT IN DUCTBANK.
2 1 0 2 4FT
VERTICAL SCALE 1"= 2'
LEGEND
- PROPOSED SECTIONALIZER
- PROPOSED UNDERGROUND CABLE ROUTING
- PROPOSED DUCTBANK
SEE DRAWING
E-102 FOR BUILDING
AND CONDUIT
TERMINATION LOCATION
INFORMATION
SECTIONALIZER S3
SECTIONALIZER S2
SECTIONALIZER S4
05 5 10FTSCALE: 1"=5'
A8
ENLARGED PLAN VIEW AT
SECTIONALIZER
TECH 1
S3
TECH 2
S2
MICB 1 & 2
TECH 1
AREA UTILITY
PV 1 & 2
TECH 2
D1
XE103
A8
XE102
A1
XE301
010 5 10 20FTSCALE: 1"=10'
D1
ENLARGED PLAN VIEW AT
POWER DISTRIBUTION CENTER
TR
U
E N
SEE NOTE 13
COMM LINE
HAND
HOLE
A1
XE303
A1
XE501
A1
XE501
A9
XE301
SEE NOTE 16
START OF PDC
JOINT DUCTBANK
E1
XE303
FRONT
FUTURE PDC
ELECTRIC UTILITY
SEE E-101
A7
XE303
E7
XE303
Clay J. Stocklin
Digitally signed by Clay J.
Stocklin
DN: C=US,
E=clay.stocklin@powereng.com, O="POWER Engineers, Inc.", OU=Distribution Services Dept I, CN=Clay J. Stocklin Location: Hailey, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info:
Date: 2020.09.02 12:46:52-06'00'
NORTH
PLAN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
XE103
PL
AN
A N
D P
R O
FI
LE
M
IC
B
AN
D
, T
EC
H
A
N D
S.
A
R N
O
LD
G . S
IZ
EM
O R
E
C . S
TO
C
KL
IN
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SI
LE
D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
2020 10 0 40FTSCALE: 1"=20'
D1
PLAN VIEW - MICB 1 AND 2, TECH 1 AND 2
2020 10 0 40FTSCALE: 1"=20'
A3
PROFILE VIEW - MICB 1 AND 2, TECH 1 AND 2
HORIZONTAL SCALE 1"= 20'
SCALE: 1"=20'
A1
PROFILE VIEW - MICB 1 AND 2
SCALE: 1"=20'
F1
PLAN VIEW - MICB 1 AND 2
TR
U
E
NTR
U E
N
XE104
D1 GENERAL NOTES: THIS SHEET ONLY
1. THE UTILITIES AND NATURAL FEATURES SHOWN HEREON ARE BASED ON
FIELD SURVEYS, AERIAL PHOTOGRAPHY AND RECORD DOCUMENTS. OTHER
FACILITIES MAY EXIST NOT DISCOVERED THROUGH THE RECORD CHECK.
THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION, BOTH HORIZONTAL
AND VERTICAL, OF ALL UTILITIES.
2. CONTROL POINTS AND TOPOGRAPHY ARE TAKEN FROM SURVEY
INFORMATION RECEIVED FROM CONTROLPOINT SURVEYING, INC. 615 PIIKOI
STREET, SUITE 700 HONOLULU, HAWAII 96814, DATED ON DECEMBER 03, 2019
WITH FILE NAME : 16091-01 AEC_FINAL.DWG
3. FOR PLANT COORDINATES REFER TO :
VERTICAL DATUM
"FELIPE" BRASS DISK
N 3269789.30 E 2624088.52
EL 43.38 MSL (US FT)
HORIZONTAL DATUM
UTM 58 NORTH
4. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RETURNED TO THE
ORIGINAL CONDITION OR BETTER AS DETERMINED BY GOVERNMENT.
5. ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CONTRACT SPECIFICATIONS OR APPROPRIATE
INDUSTRY STANDARDS WHERE INDICATED.
6. THE CONTRACTOR SHALL VERIFY AND CHECK ALL DIMENSIONS AND DETAILS
ON THE DRAWINGS BEFORE PROCEEDING WITH THE WORK. ANY
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER FOR CLARIFICATION PRIOR TO THE FABRICATION
AND /OR ORDERING OF MATERIAL.
7. RESTORATION OF ROADS AND ALL OTHER IMPROVEMENTS, UNAVOIDABLY
DAMAGED SHALL BE REPAIRED AND COST BORNE BY THE CONTRACTOR.
8. THE CONTRACTOR SHALL BE REQUIRED TO PROVIDE ADEQUATE, SAFE,
NON-SKID BRIDGING MATERIAL OVER THE TRENCH, INCLUDING SHORING,
WHEN TRENCHING IN ROAD AREAS TO HANDLE ALL TYPES OF VEHICULAR
TRAFFIC.
9. WHEN EXCAVATION IS ADJACENT TO OR UNDER EXISTING STRUCTURES OR
FACILITIES, THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SHEETING
AND BRACING THE EXCAVATION AND STABILIZING THE EXISTING GROUND TO
RENDER IT SAFE AND SECURE FROM POSSIBLE SLIDES, CAVE-INS, AND
SETTLEMENTS, AND FOR PROPERLY SUPPORTING EXISTING STRUCTURES
AND FACILITIES WITH BEAMS, STRUTS OR UNDERPINNING TO FULLY
PROTECT IT FROM DAMAGE.
10. ALL MATERIALS FOR THIS PROJECT SHALL BE NEW AND FREE FROM ANY AND
ALL DEFECTS UNLESS SPECIFIED OTHERWISE.
11. DUCT BANK SHALL MAINTAIN A MINIMUM COVER DEPTH OF 2'-0" BELOW
GRADE.
12. DUCT BANK SHALL MAINTAIN MINIMUM HORIZONTAL CLEARANCE OF 1'-0" AND
A MINIMUM VERTICAL CLEARANCE OF 1'-0" OVER OR UNDER EXISTING
UTILITIES, UNLESS OTHERWISE SHOWN ON DRAWINGS.
13. ENTER JC MANHOLE ON SOUTHWEST FACE, NORTH OF EXISTING CONDUITS.
REMOVE FILLED CONCRETE KNOCKOUT AND TERMINATE TRENCH SECTION
A9. SEE DETAIL A1 ON XE502.
14. DO NOT INSTALL 4" COMMUNICATION CONDUIT IN DUCTBANK.
15. CONTRACTOR TO FIELD DETERMINE DUCTBANK ENTRY INTO MANHOLE. SEE
DETAIL A6 ON XE302.
2 1 0 2 4FT
VERTICAL SCALE 1"= 2'
2020 10 0 40FT
TECH 1 AND 2
INSTALLED IN
EXISTING DUCTBANK
START AT JC MH #2
(SEE NOTE 13)
LEGEND
- PROPOSED SECTIONALIZER
- PROPOSED UNDERGROUND CABLE ROUTING
- PROPOSED DUCTBANK
SEE NOTE 15
SEE NOTE 14
SEE DRAWING
E-102 FOR BUILDING
AND CONDUIT
TERMINATION LOCATION
INFORMATION
05 5 10FTSCALE: 1"=5'
A8
ENLARGED PLAN VIEW AT
SECTIONALIZER
PV 1 & 2
S4
PV 1 & 2
MICB 1 & 2
AND TECH 1 & 2
PV 1 & 2 COMING OUT OF
MANHOLE
F1
XE103
A9
XE301
A9
XE301
D1
XE301
D1
XE102
A1
XE502
A1
XE501
A8
XE103
JC MH #2
SEE NOTE 15
2020 10 0 40FT
HORIZONTAL SCALE 1"= 20'
2 1 0 2 4FT
VERTICAL SCALE 1"= 2'
START OF PDC
JOINT DUCTBANK
FRONT
Clay J. Stocklin
Digitally signed by Clay J. Stocklin
DN: C=US,
E=clay.stocklin@powereng.com, O="POWER Engineers, Inc.", OU=Distribution Services Dept I, CN=Clay J. Stocklin Location: Hailey, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info:
Date: 2020.09.02 12:47:45-06'00'
2020 10 0 40FTSCALE: 1"=20'
D1
PLAN VIEW - TECH 1 AND 2
NORTH
PLAN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
XE104
PL
AN
V
IE
W
TE
C H
A
N D
S.
A
R N
O
LD
G . S
IZ
EM
O R
E
C . S
TO
C
KL
IN
S.
C
R
EA
R
TA
(1
) D
ES
IG
N
S U
BM
IT
TA
L
SE
P
RTA (100%) DESIGN SUBMITTAL
M
EC
K
IS
LA
N
D , U
.S . A
R M
Y G
AR
R
IS
O
N K
W
AJ
AL
EI
N A
TO
LL
(U
SA
G -K
A) C
O N
TA
IN
ER
IZ
ED
P
O W
ER
P
LA
N
T
AN
D E
LE
C
TR
IC
AL
D
IS
TR
IB
U
TI
O
N
FY
U
.S . M
IS
SI
LE
D
EF
EN
SE
A
G
EN
C Y
R
EP
U
BL
IC
O
F
TH
E M
AR
SH
AL
L
IS
LA
N D
S
H O
N O
LU
LU
D
IS
TR
IC
T
BL
D G
(C
EC
T-
PO
H
FT
. S
H
AF
TE
R
, H I 9
-5
SE
P
W
A-
-D
-0
AN
SI
D
TRUE N
GENERAL NOTES: THIS SHEET ONLY
1. THE UTILITIES AND NATURAL FEATURES SHOWN HEREON ARE BASED ON
FIELD SURVEYS, AERIAL PHOTOGRAPHY AND RECORD DOCUMENTS. OTHER
FACILITIES MAY EXIST NOT DISCOVERED THROUGH THE RECORD CHECK.
THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION, BOTH HORIZONTAL
AND VERTICAL, OF ALL UTILITIES.
2. CONTROL POINTS AND TOPOGRAPHY ARE TAKEN FROM SURVEY
INFORMATION RECEIVED FROM CONTROLPOINT SURVEYING, INC. 615 PIIKOI
STREET, SUITE 700 HONOLULU, HAWAII 96814, DATED ON DECEMBER 03, 2019
WITH FILE NAME : 16091-01 AEC_FINAL.DWG
3. FOR PLANT COORDINATES REFER TO :
VERTICAL DATUM
"FELIPE" BRASS DISK
N 3269789.30 E 2624088.52
EL 43.38 MSL (US FT)
HORIZONTAL DATUM
UTM 58 NORTH
4. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RETURNED TO THE
ORIGINAL CONDITION OR BETTER AS DETERMINED BY GOVERNMENT.
5. ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CONTRACT SPECIFICATIONS OR APPROPRIATE
INDUSTRY STANDARDS WHERE INDICATED.
6. THE CONTRACTOR SHALL VERIFY AND CHECK ALL DIMENSIONS AND DETAILS
ON THE DRAWINGS BEFORE PROCEEDING WITH THE WORK. ANY
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER FOR CLARIFICATION PRIOR TO THE FABRICATION
AND /OR ORDERING OF MATERIAL.
7. RESTORATION OF ROADS AND ALL OTHER IMPROVEMENTS, UNAVOIDABLY
DAMAGED SHALL BE REPAIRED AND COST BORNE BY THE CONTRACTOR.
8. ALL MATERIALS FOR THIS PROJECT SHALL BE NEW AND FREE FROM ANY AND
ALL DEFECTS UNLESS SPECIFIED OTHERWISE.
XE
D
XE
D
TECH 1 AND 2
INSTALLED IN
EXISTING DUCTBANK
VIEW ROTATED 84 DEGREES
LEGEND
- PROPOSED SECTIONALIZER
- PROPOSED UNDERGROUND CABLE ROUTING
- PROPOSED DUCTBANK
JC MH #3
A5
XE502
Clay J. Stocklin
Digitally signed by Clay J. Stocklin
DN: C=US,
E=clay.stocklin@powereng.com, O="POWER Engineers, Inc.", OU=Distribution Services Dept I, CN=Clay J. Stocklin Location: Hailey, ID Reason: I agree to the terms defined by the placement of my signature on this document Contact Info:
Date: 2020.09.02…
This is the start of the file's text. The full file is on GovTribe.