A_-_25-01-ITB_-_Attachment_A_-_Civil_Plans.pdf

PDF 5 MB Posted

Attached to
Barber Street Sports Complex Backstop Replacement
Solicitation number
25-01-ITB
Issued by
Indian River County, Florida

About this file

These are civil engineering design plans prepared by Schulke, Bittle & Stoddard, L.L.C. for the City of Sebastian, Florida, detailing the replacement of four baseball backstops at the Barber Street Sports Complex. The comprehensive set of drawings (sheets C-1 through C-4) provides detailed site plans, sections, fence details, and specifications for the backstop replacement project. The plans specify replacing existing backstops with new 6 5/8" galvanized pipe posts, 2" chain link fencing, and associated footings, with each backstop measuring approximately 45' wide and 20' high. The project involves removing existing backstops, sawcutting and repairing concrete slabs, setting new posts in 16" or 24" diameter footings, and reinstalling existing netting.

The technical specifications outline precise requirements for materials, including 9-gauge zinc-coated chain link fabric, Schedule 40 galvanized steel pipes, tension wires, and fittings. Concrete footings must achieve 2,500 psi compressive strength, and posts must be set plumb with specific spacing and reinforcement. The plans include detailed installation instructions covering post placement, fabric attachment, ground restoration, and hardware installation. The project appears to be funded by the City of Sebastian and is designed to maintain and upgrade the sports complex's infrastructure, with careful attention to technical specifications and construction standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D R A W

IN

G

D A T E

D E S

IG

N E D

D R A W N

C H E C K E D

S C A

LE

R E V

IS

IO

N

M A R K

D A T E

I N

D

IA

N R

IV

ER

B

LV

D

S U

IT

E

V

ER

O B

EA

C

H

FL

O

R

ID

A

S C

H U

LK

E

, B

IT

T

LE

S

T O

D D

A R

D

L.

L.

C

TE

L

/ 7

-9

F

AX

0-

E M

AI

L in fo sb se ng in ee rs .c om

ENGINEER CERTIFICATION

DATE:

FL. REG. NO. 47048

SHEET

FL. REG. NO. 57605

WILLIAM P. STODDARD

JODAH B. BITTLE

FL. REG. NO. 57396

JOSEPH W. SCHULKE

PROJECT NO.

J.

W .S

W

JF

J.

W .S

N .T .S

BACKSTOP TO

BE REPLACED

SEE SHEET C-2

BACKSTOP TO

BE REPLACED

SEE SHEET C-2

BACKSTOP TO

BE REPLACED

SEE SHEET C-2

BACKSTOP TO

BE REPLACED

SEE SHEET C-2

SHEET LIST TABLE

SHEET

NUMBER SHEET TITLE

C-1 SITE PLAN - BASEBALL BACKSTOP BARBER STREET COMPLEX

C-2 SITE PLAN & SECTIONS - BASEBALL BACKSTOP

C-3 FENCE DETAILS - BASEBALL BACKSTOP

SPECIFICATIONS & STRUCTURAL DETAILS - BASEBALL BACKSTOPC-4

VICINITY MAP

SITE

N

TULIP DR.

BARBER ST.

ROSEBUSH TERRACE

PERSIAN LN.

Docusign Envelope ID: 8457316A-98F2-4D84-B104-239BDB39F2BD

10/1/2024

X

AutoCAD SHX Text THE DRAWINGS ARE THE PROPERTY OF THE ENGINEER. WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. COPY OR USE FOR OTHER PROJECTS IS PERMITTED ONLY BY WRITTEN CONTRACT WITH THE ENGINEER. UNAUTHORIZED USE WILL BE PROSECUTED PURSUANT TO THE COPYRIGHT LAWS.

AutoCAD SHX Text

CIVIL & STRUCTURAL ENGINEERING LAND PLANNING ENVIRONMENTAL PERMITTING

AutoCAD SHX Text

CERTIFICATION OF AUTHORIZATION NO.: 00008668

AutoCAD SHX Text 24-095

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

CITY OF SEBASTIAN

AutoCAD SHX Text

SPORTS COMPLEX

AutoCAD SHX Text

SEBASTIAN, FLORIDA

AutoCAD SHX Text C-1

AutoCAD SHX Text

BASEBALL BACKSTOPS BARBER STREET SPORT COMPLEX

A C-2

SECTION THRU BACKSTOP

SCALE: 1" =5'

PRESS BOX

25'±

B C-2

SECTION THRU FENCE @ 1st & 3rd BASE LINE

SCALE: 1" =5'

D R A W

IN

G

D A T E

D E S

IG

N E D

D R A W N

C H E C K E D

S C A

LE

R E V

IS

IO

N

M A R K

D A T E

I N

D

IA

N R

IV

ER

B

LV

D

S U

IT

E

V

ER

O B

EA

C

H

FL

O

R

ID

A

S C

H U

LK

E

, B

IT

T

LE

S

T O

D D

A R

D

L.

L.

C

TE

L

/ 7

-9

0-

AI

L in fo sb se ng in ee rs .c om

ENGINEER CERTIFICATION

DATE:

FL. REG. NO. 47048

SHEET

FL. REG. NO. 57605

WILLIAM P. STODDARD

JODAH B. BITTLE

FL. REG. NO. 57396

JOSEPH W. SCHULKE

PROJECT NO.

J.

W .S

W

JF

J.

W .S

1"

A C-2

20'±

REMOVE AND

REPLACE

BACKSTOP

45'±

REMOVE AND

REPLACE

BACKSTOP

45'± R

EM

O

VE AN

D

R

EPLAC

E

BAC

KSTO

P

HOME PLATE

TIP OF HOME PLATE

B C-2

B C-2

6 5/8"Ø GALV. PIPE GROUP 1A

HIGH STRENGTH 50 KSI YIELD W/CAP

2" - 9 GA. CHAIN LINK

FENCE (GALV.)

FOOTING

EXISTING

CONCRETE

SLAB

2" - 9 GA. CHAIN LINK

FENCE (GALV.)

SEE DETAIL A

SEE DETAIL A

DETAIL A

2" - 9 GA. CHAIN LINK

FENCE (GALV.)

FOOTING

PLAYING FIELD

PLAYING FIELD

EXISTING

CONCRETE

SLAB

FILL WITH

2" TO 4" STONE

4"±

1 2" M

IN

4"

EXISTING

GRADE

1.33' (16")

OR

2' (24")

O

PT

IO

N

AL

8.

.5

F O

R

6" Ø

F O

O

TE

R 6.

F O

R

4" Ø

F O

O

TE

R

DISTURBED INFIELD SOIL

TO BE REPLACED IN KIND

(4" MINIMUM DEPTH)

DISTURBED INFIELD SOIL

TO BE REPLACED IN KIND

(4" MINIMUM DEPTH)

DISTURBED INFIELD SOIL

TO BE REPLACED IN KIND

(4" MINIMUM DEPTH)

2" TO 4" STONE

2" TO 4" STONE

3000 PSI CONCRETE

EXISTING NETTING DETACH AND

RE-ATTACH TO NEW FENCE

EXISTING NETTING DETACH AND

RE-ATTACH TO NEW FENCE

EXISTING NETTING DETACH AND

RE-ATTACH TO NEW FENCE

EXISTING NETTING DETACH AND

RE-ATTACH TO NEW FENCE

EXISTING CONDITION/DEMO DETAIL

EXISTING

CONCRETE SLAB

(TO REMAIN)

PLAYING FIELD

8"±

REMOVE EXISTING CHAINLINK

FENCE AND RAILS

REMOVE FOOTING

(UNDETERMINED DEPTH)

CONTRACTOR SHALL COORDINATE WITH

C.O.S. PUBLIC WORKS AND CAREFULLY

LOCATE EXISTING MECHANICAL, ELECTRICAL

AND PLUMBING IN VICINITY OF THE WORK

CONTRACTOR SHALL COORDINATE WITH

C.O.S. PUBLIC WORKS AND CAREFULLY

LOCATE EXISTING MECHANICAL, ELECTRICAL

AND PLUMBING IN VICINITY OF THE WORK

4"±

EXISTING

CONCRETE

SLAB

EXISTING

CONCRETE

SLAB

SAW-CUT EXISTING SLAB

AND REPAIR WITH NEW

CONCRETE IN KIND

16"Ø OR 24"Ø FOOTER

SECTION C

C

SAW-CUT EXISTING SLAB

AND REPAIR WITH NEW

CONCRETE IN KIND

EXISTING 4" POLE

(TO BE REMOVED)

6 5/8"Ø GALV. PIPE GROUP 1A

HIGH STRENGTH 50 KSI YIELD

6 5/8"Ø GALV. PIPE GROUP 1A

HIGH STRENGTH 50 KSI YIELD W/CAP

6 5/8"Ø GALV. PIPE GROUP 1A

HIGH STRENGTH 50 KSI YIELD

Docusign Envelope ID: 8457316A-98F2-4D84-B104-239BDB39F2BD

10/1/2024

X

AutoCAD SHX Text THE DRAWINGS ARE THE PROPERTY OF THE ENGINEER. WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. COPY OR USE FOR OTHER PROJECTS IS PERMITTED ONLY BY WRITTEN CONTRACT WITH THE ENGINEER. UNAUTHORIZED USE WILL BE PROSECUTED PURSUANT TO THE COPYRIGHT LAWS.

AutoCAD SHX Text

CIVIL & STRUCTURAL ENGINEERING LAND PLANNING ENVIRONMENTAL PERMITTING

AutoCAD SHX Text

CERTIFICATION OF AUTHORIZATION NO.: 00008668

AutoCAD SHX Text 24-095

AutoCAD SHX Text

CITY OF SEBASTIAN

AutoCAD SHX Text

SPORTS COMPLEX

AutoCAD SHX Text

SEBASTIAN, FLORIDA

AutoCAD SHX Text C-2

AutoCAD SHX Text inch = ft.

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

GRAPHIC SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SITE PLAN (10 SCALE) AND SECTIONS BASEBALL BACKSTOPS BARBER STREET SPORT COMPLEX

3 SPACES @ 8.33' = 25'

6 SPACES @

7.5' = 45'

135°135°

6 S

PACES @

7.

5'

= 4 5'

D R A W

IN

G

D A T E

D E S

IG

N E D

D R A W N

C H E C K E D

S C A

LE

R E V

IS

IO

N

M A R K

D A T E

I N

D

IA

N R

IV

ER

B

LV

D

S U

IT

E

V

ER

O B

EA

C

H

FL

O

R

ID

A

S C

H U

LK

E

, B

IT

T

LE

S

T O

D D

A R

D

L.

L.

C

TE

L

/ 7

-9

0-

AI

L in fo sb se ng in ee rs .c om

ENGINEER CERTIFICATION

DATE:

FL. REG. NO. 47048

SHEET

FL. REG. NO. 57605

WILLIAM P. STODDARD

JODAH B. BITTLE

FL. REG. NO. 57396

JOSEPH W. SCHULKE

PROJECT NO.

J.

W .S

W

JF

J.

W .S

A S

N O T E D

FINISH GRADE

6" BRACE BAND (TYP)

6" OD POST

16" HEX NUT (TYP)

2" OD PIPE (TYP)

16" X 2 1

2" CARRIAGE BOLT

(TYP)

16" X 1 1

2" CARRIAGE BOLT

(TYP AT BRACE BANDS)

2" RAIL END

OFFSET LUG (TYP)

CHAINLINK FABRIC

16" X 1 "

CARRIAGE BOLT &

NUT

6" OD POST

" X 3

4" TENSION BAR . ONE PIECE LENGTH EQUAL TO 2"

LESS THAN FULL HEIGHT OF FABRIC.

BRACE AND TENSION BAND

RAIL CONNECTION (NTS) FABRIC CONNECTION (NTS)

BACKSTOP PLAN VIEW

CORNER POST

LINE POST

END POST

2" O.D. RAILS (TYP)

2" O.D. RAILS

2"

4'

A C-3

SECTION A

8' 8'

CHAINLINK BASEBALL BACKSTOP

N.T.S.

2" - 9 GA. CHAINLINK

FABRIC (TYP)

2" - 9 GA. CHAINLINK

FABRIC (TYP)

O

PT

IO

N

AL

F O

R

6" Ø

F O

O

TE

R

.8

F O

R

4" Ø

F O

O

TE

R

FENCE POST FOOTING FOR BASEBALL BACKSTOP

N.T.S.

.3 3'

8"

EXISTING CONCRETE SLAB

EXISTING GRADE

2"

3000 PSI CONCRETE FOOTING

MINIMUM 28 DAY COMPRESSIVE

STRENGTH

2" O.D. RAILS

4"

2"

M

AX

. 1 5"

O .C

INTENT IS TO PLACE BACKSTOP IN SAME

LOCATION AS EXISTING BACKSTOP

DOME POST

TOP CAP2" O.D. TOP RAIL

2" O.D. RAILS (TYP)

2" O.D. RAIL

9 GA. WIRE TIES 15" O.C.

O

PT

IO

N

AL

8.

.5

F O

R

6" Ø

F O

O

TE

R 6.

F O

R

4" Ø

F O

O

TE

R

3/8"Ø GALV. STEEL TRUSS ROD

W/TURNBUCKLE (TYP AT EACH

END AND CORNER)

3/8"Ø GALV. STEEL TRUSS ROD

W/TURNBUCKLE (TYP)

2" O.D. RAILS

3/8"Ø GALV. STEEL TRUSS ROD

W/TURNBUCKLE (TYP)

6 5/8"Ø GALV. PIPE GROUP 1A

HIGH STRENGTH 50 KSI YIELD

6 5/8"Ø GALV. PIPE GROUP 1A

HIGH STRENGTH 50 KSI YIELD

6 5/8"Ø GALV. PIPE GROUP 1A

HIGH STRENGTH 50 KSI YIELD W/CAP

1.33' (16")

OR

2' (24")

O

PT

IO

N

AL

8.

.5

F O

R

6" Ø

F O

O

TE

R 6.

F O

R

4" Ø

F O

O

TE

R

8"

Docusign Envelope ID: 8457316A-98F2-4D84-B104-239BDB39F2BD

X

10/1/2024

AutoCAD SHX Text THE DRAWINGS ARE THE PROPERTY OF THE ENGINEER. WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. COPY OR USE FOR OTHER PROJECTS IS PERMITTED ONLY BY WRITTEN CONTRACT WITH THE ENGINEER. UNAUTHORIZED USE WILL BE PROSECUTED PURSUANT TO THE COPYRIGHT LAWS.

AutoCAD SHX Text

CIVIL & STRUCTURAL ENGINEERING LAND PLANNING ENVIRONMENTAL PERMITTING

AutoCAD SHX Text

CERTIFICATION OF AUTHORIZATION NO.: 00008668

AutoCAD SHX Text 24-095

AutoCAD SHX Text

CITY OF SEBASTIAN

AutoCAD SHX Text

SPORTS COMPLEX

AutoCAD SHX Text

SEBASTIAN, FLORIDA

AutoCAD SHX Text C-3

FENCE DETAILS BASEBALL BACKSTOPS BARBER STREET SPORT COMPLEX

D R A W

IN

G

D A T E

D E S

IG

N E D

D R A W N

C H E C K E D

S C A

LE

R E V

IS

IO

N

M A R K

D A T E

I N

D

IA

N R

IV

ER

B

LV

D

S U

IT

E

V

ER

O B

EA

C

H

FL

O

R

ID

A

S C

H U

LK

E

, B

IT

T

LE

S

T O

D D

A R

D

L.

L.

C

TE

L

/ 7

-9

0-

AI

L in fo sb se ng in ee rs .c om

ENGINEER CERTIFICATION

DATE:

FL. REG. NO. 47048

SHEET

FL. REG. NO. 57605

WILLIAM P. STODDARD

JODAH B. BITTLE

FL. REG. NO. 57396

JOSEPH W. SCHULKE

PROJECT NO.

W P S

W

JF

W P S

A S

N O T E D

2" - 9 GA. CHAIN LINK

FENCE (GALV.)

EXISTING

CONCRETE

SLAB

FILL WITH

2" TO 4" STONE

4"±

1 2" M

IN

4"

EXISTING

GRADE

DISTURBED INFIELD SOIL

TO BE REPLACED IN KIND

(4" MINIMUM DEPTH)

4"±

EXISTING

CONCRETE

SLAB

EXISTING

CONCRETE

SLAB

SAW-CUT EXISTING SLAB

AND REPAIR WITH NEW

CONCRETE IN KIND (3000 PSI)

SECTION C

C

SAW-CUT EXISTING SLAB

AND REPAIR WITH NEW

CONCRETE IN KIND (3000 PSI)

#3 TIES

6 - #4 REBAR

(TYP 6 PLACES)

#3 TIES

#4 REBAR

#4 REBAR

SECTION 02802

CHAIN LINK FENCE

GENERAL

Description

The contractor shall furnish all labor, materials, equipment, and incedentals required to install chain link fence at the location(s) and to the height designated on the plans.

Quality Assurance

Comply with standards of the Chain Link Fence Manufacturer's Institute for chain link fence fabric and Industrial Steel Specifications for fence posts, gates and accessories, and as herein specified.

Provide each type of steel fence and gates as a complete unit produced by a single manufacturer, including necessary erection accessories, fittings and fastenings.

Submittals

Samples: provide representative samples of chain link fabric (1' x 1' minimum), framework and fittings.

Shop Drawings: Schematic drawing showing layout of fence location with dimensions, elevation, footing, details of attachments, and list any proposed deviations from owner's plan.

Product Data: Manufacturer's catalog cuts, specifications, installation instructions and maintenance data.

PRODUCTS

1. Chain link, No. 9 gauge, 2" mesh.

Steel Chain Link Fabric: 9 gauge core, 2” mesh, 1290 lbf wire break strength, fabric salvage knuckle finish top and bottom; Zinc-Coated Steel Fabric: ASTM A392 hot dipped galvanized before weaving (GBW) or after weaving (GAW); Class 2 - 2.0 oz/ft² (610 g/m²)

2. Round steel pipe and rail: Schedule 40 standard weight pipe, in accordance with ASTM F1083, 1.8 oz/ ft² (550 g/m²) hot dip galvanized zinc exterior and 1.8 oz/ft² (550 g/m²) hot dip galvanized zinc interior coating.

- Rails: 2" regular grade, 30,000 psi

- Posts: 6 5/8"; group 1A, 50,000 psi

1. Line post: 6 58/” outside diameter

2. End, Corner, Pull post: 6 5/8” outside diameter

3. Top, brace, bottom and intermediate rails, 1.92” outside diameter, 2.72 lb/ft

3. Tension Wire: Metallic Coated Steel Marcelled Tension Wire: 7 gauge core (0.177 in.) (4.50 mm) marcelled wire complying with ASTM; Type II Zinc-Coated, ASTM A817 Class 5 - 2.0 oz/ft² (610 g/m²)

4. Fittings

A.Tension and Brace Bands: Galvanized pressed steel complying with ASTM F626, minimum steel thickness of 12 gauge (0.105 in.) (2.67 mm), minimum width of 3/4 in. (19 mm) and minimum zinc coating of 1.20 oz/ft² (366 g/m²). Secure bands with 5/16 in. (7.94 mm) galvanized steel carriage bolts.

B.Terminal Post Caps, Line Post Loop Tops, Rail and Brace Ends, Boulevard Clamps, Rail Sleeves: In compliance to ASTM F626, pressed steel galvanized after fabrication having a minimum zinc coating of 1.20 oz/ft² (366 g/m²).

C.Truss Rod Assembly: In compliance with ASTM F626, 3/8 in. (9.53 mm)) diameter steel truss rod with a pressed steel tightener, minimum zinc coating of 1.2 oz/ft² (366 g/m²), assembly capable of withstanding a tension of 2,000 lbs. (970 kg).

D.Tension Bars: In compliance with ASTM F626. Galvanized steel one-piece length 2 in. (50 mm) less than the fabric height. Minimum zinc coating 1.2 oz. /ft² (366 g/m²).

*[Bars for 2 in. (50 mm) and 1 ¾ in. (44 mm) mesh shall have a minimum cross section of 3/16 in. (4.8 mm) by 3/4 in. (19 mm)]

5. Tie wire and Hog rings: 9 gauge core (0.148) (3.76 mm) steel Galvanized Before Weave (GBW) with preformed power fastened wire ties and 11 gauage preformed hog rings having minimum zinc coating 1.20 oz/ft² (366 g/m²) per

ASTM F626.

9 gauge galvanized wire shall be spaced 12" O.C. for tying fabric to line posts and 9 gauge galvanized wire spaced 15" O.C. for tying fabric to rails and braces. Use 11 gauge hog rings spaced 24" O.C. for tying fabric to tension wire

6. Concrete : concrete for post footings shall have a 28-day compressive strength of 2,500 psi. (17.2 MPa).

EXECUTION

Preparation

Surveying, clearing, grubbing, grading and removal of debris for the fence line or any required clear areas adjacent to the fence

In areas to be graded by others, wait until finished grading is completed before beginning fence installation.

Installation

Space posts equidistant in the fence line with a maximum of 10 feet on center. Posts shall be set plumb in concrete footings in accordance with ASTM F567.

Earth: Excavate holes 16" in diameter for end, pull, corner and gate posts, and 16" in diameter for line posts, depth per plan. Set posts in center of hole, set steel reinforcement (if required per plan) and cast 2500 psi concrete in ground.

Vibrate or tamp for consolidation. .

Check each post for vertical and top alignment. When directed, set posts perpendicular to ground surface.

Locate corner posts at corners and at changes in direction. Use pull posts at all abrupt changes in grade and at intervals no greater than 500 feet. On runs over 500 feet, space pull posts evenly between corner or end posts. On long curves, space pull posts so that the strain of the fence will not bend the line posts.

Provide top, bottom and intermediate horizontal rail bracing between all terminal posts, corner posts, pull posts and adjacent line posts as per plan.

Provide truss rods with turnbuckle attachment and install diagonally between terminal posts, corner posts, pull posts and adjacent line posts where depicted on plans.

Attach fabric to security side of fence after concrete has cured a minimum of 7 days. Maintain a 2-inch clearance above finished grade. Thread stretcher bars through fabric and secure to posts with metal band 15" O.C. Pull fabric taut and securely tie to posts, rails and tension wires in order to maintain tension after pulling force is released.

Install nuts for tension band and hardware bolts on side of fence opposite fabric side. Peen ends of bolts or score threads to prevent removal of nuts.

Install gates plumb and level and adjust for full opening without interference. Install ground-set items in concrete for anchorage, as recommended by fence manufacturer. Adjust hardware for smooth operation and lubricate where necessary.

Support bottom edge of fabric with coil spring tension wire. Weave tension wire through fabric or fasten with hog rings spaced 24" O.C. Tie tension wire to posts with 6 gauge appropriately coated wire.

Restore disturbed ground areas to original condition.

3000 PSI CONCRETE

6 5/8"Ø GALV. PIPE GROUP 1A

HIGH STRENGTH 50 KSI YIELD

6 5/8"Ø GALV. PIPE GROUP 1A

HIGH STRENGTH 50 KSI YIELD

1.33' (16")

OR

2' (24")

8"

16"Ø OR 24"Ø FOOTER

#3

T

IE

S

" O

.C

#3

T

IE

S

2"

O .C

.O

PT

IO

N

AL

8.

.5

F O

R

6" Ø

F O

O

TE

R 6.

F O

R

4" Ø

F O

O

TE

R

#3 TIES

#3 TIES

Docusign Envelope ID: 8457316A-98F2-4D84-B104-239BDB39F2BD

10/1/2024

X

AutoCAD SHX Text

M-16 AT INTERSECTING WALLS FIFTY PERCENT OF THE MASONRY SHALL

AutoCAD SHX Text

HEIGHT OF MASONRY WALLS. PROVIDE CLEAN-OUT HOLES AT BASE

AutoCAD SHX Text

OF FILLED CELL WHEN THE CONCRETE POUR EXCEEDS 5 FEET IN

AutoCAD SHX Text

M-17 REFER TO TYPICAL WALL SECTIONS FOR MAXIMUM CONSTRUCTION

AutoCAD SHX Text

M-20 ALL REINFORCED CELLS ARE TO BE CLEAN AND FREE OF ANY FOREIGN

AutoCAD SHX Text

AND SHALL CONTAIN AT LEAST ONE CROSS WIRE OF EACH PIECE

AutoCAD SHX Text

M-15 JOINT REINFORCEMENT SHALL BE LAPPED AT LEAST 6" AT SPLICES

AutoCAD SHX Text

REINFORCEMENT ABOVE GRADE BEAM AND ABOVE EACH FLOOR

AutoCAD SHX Text

M-11 REINFORCING BARS SHALL BE LAPPED 48 BAR DIAMETERS WHERE

AutoCAD SHX Text

BARS SHALL NOT BE LESS THAN ONE BAR DIAMETER OR 1". CENTER

AutoCAD SHX Text

TYPE CELL CAPS. PROVIDE CORNER BARS AT ALL BEAM CORNERS

AutoCAD SHX Text

DRAWINGS AT EACH FLOOR AND THE ROOF. USE GALVANIZED MESH

AutoCAD SHX Text

SHALL BE PROVIDED IN ALL WALLS SHOWN ON THE STRUCTURAL

AutoCAD SHX Text

M-7 A REINFORCED CONCRETE TIE BEAM OR MASONRY TIE BEAM

AutoCAD SHX Text

M-13 PLACE ALL MASONRY IN RUNNING BOND WITH 3/8" MORTAR JOINTS.

AutoCAD SHX Text

CLEARANCE OF 1/2" FROM MASONRY. THE CLEAR DISTANCE BETWEEN

AutoCAD SHX Text

AND BOTTOM OF BAR AND AT 8'-0" OC MAXIMUM WITH A MINIMUM

AutoCAD SHX Text

M-19 VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE TOP

AutoCAD SHX Text

D. AT ANCHORAGE OF CONNECTIONS OR BEARING OF BEAMS

AutoCAD SHX Text

(DUR-O-WALL OR EQUAL) IN BED JOINTS AT 16" O.C. MEASURED

AutoCAD SHX Text

M-14 PROVIDE HORIZONTAL WALL REINFORCEMENT 9 GA. LADDER TYPE

AutoCAD SHX Text

M-9 VERTICAL REINFORCING FOR FILLED CELLS SHALL CONFORM TO

AutoCAD SHX Text

M-12 PROVIDE FULL MORTAR BEDDING AROUND ALL FILLED CELLS WITH

AutoCAD SHX Text

M-10 PROVIDE VERTICAL REINFORCEMENT IN GROUT FILLED CELLS:

AutoCAD SHX Text

REDUCED IN SIZE OR STRENGTH WITHOUT PRIOR APPROVAL IN

AutoCAD SHX Text

G-9 REVIEW ALL SHOP DRAWINGS FOR CONFORMANCE WITH THE CONTRACT

AutoCAD SHX Text

G-8 THE ENGINEER SHALL NOT BE RESPONSIBLE FOR LAYOUT,

AutoCAD SHX Text

G-7 THE INTENTION OF THE PLANS AND SPECIFICATIONS IS TO PROVIDE

AutoCAD SHX Text

G-6 ALL DETAILS AND SECTIONS ON THE DRAWINGS ARE INTENDED TO BE

AutoCAD SHX Text

G-5 COORDINATE STRUCTURAL AND OTHER DRAWINGS THAT ARE PART OF

AutoCAD SHX Text

DOCUMENTS AND FOR COMPLETENESS AND ANSWER ALL CONTRACTOR

AutoCAD SHX Text

REVIEW. NON-COMPLIANCE WITH THIS REQUIREMENT WILL RESULT IN

AutoCAD SHX Text

SUBMITTING SHOP DRAWINGS TO ARCHITECT/ENGINEER FOR

AutoCAD SHX Text

RELATED QUESTIONS. STAMP AND INITIAL ALL SHEETS PRIOR TO

AutoCAD SHX Text

REJECTION OF SUBMITTAL.

AutoCAD SHX Text

WRITING FROM THE STRUCTURAL ENGINEER.

AutoCAD SHX Text

ELECTRICAL, PLUMBING, DUCTWORK, ETC.)

AutoCAD SHX Text

ACCURATELY LAYOUT, COORDINATE, DETAIL, FABRICATE AND

AutoCAD SHX Text

CONTRACTOR NOR SUBCONTRACTORS FROM THEIR RESPONSIBILITY TO

AutoCAD SHX Text

WHOLE OR ANY PART IN SHOP DRAWINGS SHALL NOT RELIEVE THE

AutoCAD SHX Text

SHOP DRAWINGS. USE OF CONTRACT DRAWINGS REPRODUCED IN

AutoCAD SHX Text

REPRODUCTION AND USE OF CONTRACT DRAWINGS FOR ERECTION AND

AutoCAD SHX Text

DIMENSIONAL ERRORS OR DISCREPANCIES RESULTING FROM THE

AutoCAD SHX Text

CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE

AutoCAD SHX Text

WHEN SPECIFIC INFORMATION IS MISSING OR IS IN CONFLICT. THE

AutoCAD SHX Text

ALL NECESSARY DETAILS TO CONSTRUCT A COMPLETE STRUCTURE.

AutoCAD SHX Text

SITUATION ELSEWHERE ON THE PROJECT EXCEPT WHERE A SEPARATE

AutoCAD SHX Text

TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR

AutoCAD SHX Text

ITEMS WHICH MAY AFFECT THE STRUCTURAL DRAWINGS (I.E. MECHANICAL,

AutoCAD SHX Text

THE CONTRACT DOCUMENTS FOR ANCHORED, EMBEDDED OR SUPPORTED

AutoCAD SHX Text

INSTALL A COMPLETE STRUCTURE.

AutoCAD SHX Text

ARCHITECT/ENGINEER.

AutoCAD SHX Text

DETAIL IS SHOWN.

AutoCAD SHX Text

PLACEMENT OF COLUMNS, BEAMS AND SLABS FOR THE SAME STORY.

AutoCAD SHX Text

MORTAR SHALL CONFORM TO ASTM C270 (PROPORTION OR PROPERTY

AutoCAD SHX Text

TYPE II. MINIMUM NET COMPRESSIVE UNIT STRENGTH OF 2000 PSI

AutoCAD SHX Text b.) 1/4" MAXIMUM AGGREGATE SIZE

AutoCAD SHX Text a.) 2500 PSI AT 28 DAYS

AutoCAD SHX Text

M-6 COARSE GROUT SHALL CONFORM TO ASTM C476:

AutoCAD SHX Text

AND TYPE "S" MORTAR FOR BELOW GRADE APPLICATIONS.

AutoCAD SHX Text

ALL MASONRY UNITS SHALL BE LAID PRIOR TO CONCRETE

AutoCAD SHX Text

SPECIFICATIONS FOR REFERENCE AT THE JOBSITE.

AutoCAD SHX Text

M-4 USE TYPE "M" MORTAR FOR ABOVE GRADE APPLICATIONS

AutoCAD SHX Text

M-3 STRUCTURE HAS BEEN DESIGNED AS A BEARING WALL STRUCTURE.

AutoCAD SHX Text TO PROVIDE NET AREA COMPRESSIVE STRENGH OF MASONRY (Fm')

AutoCAD SHX Text

M-5 MASONRY UNITS SHALL CONFORM TO ASTM C90, NORMAL WEIGHT,

AutoCAD SHX Text c.) 8" TO 11" SLUMP

AutoCAD SHX Text

OF 1500 PSI.

AutoCAD SHX Text

SPECIFICATION)

AutoCAD SHX Text

REQUIREMENTS FOR MASONRY STRUCTURES" (ACI/ASCE 530-02) AND

AutoCAD SHX Text

EXCEPT AS AMENDED BELOW.

AutoCAD SHX Text

"SPECIFICATIONS FOR MASONRY STRUCTURES" (ACI/ASCE 530.1-02)

AutoCAD SHX Text

M-2 CONTRACTOR SHALL OBTAIN COPY OF MASONRY CODE AND

AutoCAD SHX Text

M-1 MASONRY CONSTRUCTION SHALL CONFORM TO ACI "BUILDING CODE

AutoCAD SHX Text

%%UMASONRY

AutoCAD SHX Text

G-3 IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROTECT EXISTING

AutoCAD SHX Text

G-2 THE MASONRY WALLS ARE NOT DESIGNED TO WITHSTAND TEMPORARY

AutoCAD SHX Text

G-1 REVIEW ALL PROJECT DOCUMENTS PRIOR TO FABRICATION AND START

AutoCAD SHX Text

%%UGENERAL NOTES

AutoCAD SHX Text

D-4 SEISMIC: ZONE 0

AutoCAD SHX Text

G-4 NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED OR OTHERWISE

AutoCAD SHX Text

CONSTRUCTION PHASE OF THIS PROJECT.

AutoCAD SHX Text

FACILITIES, STRUCTURES AND UTILITY LINES FROM ALL DAMAGE

AutoCAD SHX Text

AT ALL TIMES TO MAINTAIN WALL STABILITY DURING THE

AutoCAD SHX Text

CONSTRUCTION LOADS. IT IS THE CONTRACTOR'S RESPONSIBILITY

AutoCAD SHX Text

STRUCTURAL ENGINEER PRIOR TO PROCEEDING WITH WORK.

AutoCAD SHX Text

OF CONSTRUCTION. REPORT ANY DISCREPANCIES TO ARCHITECT OR

AutoCAD SHX Text

DURING CONSTRUCTION.

AutoCAD SHX Text

%%USTRUCTURAL DESIGN CRITERIA

AutoCAD SHX Text D-3 ULTIMATE DESIGN WIND SPEED, Vult: 160 MPH (3 SECOND GUST)

AutoCAD SHX Text

HEIGHT, H: 20.0 FT

AutoCAD SHX Text WIND EXPOSURE CATEGORY: c

AutoCAD SHX Text

PLACEMENT USING A "PENCIL" TYPE VIBRATOR.

AutoCAD SHX Text

M-18 GROUT FOR FILLED CELLS SHALL BE VIBRATED DURING

AutoCAD SHX Text

MATERIAL OR DEBRIS.

AutoCAD SHX Text

BARS IN WALLS UNLESS NOTED OTHERWISE.

AutoCAD SHX Text

BE LAID IN OVERLAPPING MASONRY BONDING PATTERN

AutoCAD SHX Text

OF REINFORCEMENT IN THE LAPPED DISTANCE.

AutoCAD SHX Text

UNLESS NOTED OTHERWISE.

AutoCAD SHX Text

SPLICED AND SHALL BE WIRED TOGETHER. LAP VERTICAL

AutoCAD SHX Text

VERTICAL REINFORCING.

AutoCAD SHX Text

HEIGHT.

AutoCAD SHX Text

VERTICALLY.

AutoCAD SHX Text

M-8 UNLESS NOTED OTHERWISE, TIE BEAMS SHALL BE EITHER

AutoCAD SHX Text

TO MATCH HORIZONTAL BARS.

AutoCAD SHX Text

C. AT ALL CORNERS AND INTERSECTIONS

AutoCAD SHX Text

A. AS SHOWN ON THE DRAWINGS

AutoCAD SHX Text

B. 32" O.C. MAXIMUM SPACING SEE DETAILS

AutoCAD SHX Text

ASTM 615

AutoCAD SHX Text

a. 8"X16" CONCRETE TIE BEAM

AutoCAD SHX Text

REINFORCED WITH (2) #5 TOP AND BOTTOM AND

AutoCAD SHX Text

A. STRUCTURE IS ASSUMED TO BE FREE STANDING SOLID WALL.

AutoCAD SHX Text

MANUFACTURERS RECOMMENDATIONS FOR INSTALLATION OF

AutoCAD SHX Text

COMPONENTS AND CLADDING FOR HURRICANE PRONE REGIONS.

AutoCAD SHX Text

SPECIFICATIONS AND INSPECTIONS REQUIRED TO COMPLY WITH

AutoCAD SHX Text

B. OWNER OR CONTRACTOR SHALL OBTAIN NECESSARY INSTALLATION

AutoCAD SHX Text

ASSUMPTIONS:

AutoCAD SHX Text

BOTH SHALL BE CONSIDERED SATISFACTORY, PROVIDED THE MINIMUM

AutoCAD SHX Text

LESS THAN APPLICABLE SPECIFICATION REQUIREMENTS IN THE

AutoCAD SHX Text

WEIGHT OF A HAND-WIRE-BRUSHED TEST SPECIMEN ARE NOT

AutoCAD SHX Text

RC-21 PROVIDE THE FOLLOWING CONCRETE COVERAGES OVER REINFORCING:

AutoCAD SHX Text

WITH VAPOR BARRIER 2" CLR.

AutoCAD SHX Text

DIRECT CONTACT WITH SOIL 3" CLR.

AutoCAD SHX Text

FOOTINGS / GRADE BEAMS: BOTTOM AND UNFORMED EDGES

AutoCAD SHX Text

DIMENSIONS (INCLUDING HEIGHT OF DEFORMATIONS) AND

AutoCAD SHX Text

DEGREE HOOK (PLACED VERTICALLY) UNLESS NOTED OTHERWISE.

AutoCAD SHX Text

CONT. TOP STEEL AT MIDSPAN UNLESS OTHERWISE SPECIFIED.

AutoCAD SHX Text

MIN 40 BAR DIA. LAP CONT. BOTTOM STEEL OVER SUPPORT AND

AutoCAD SHX Text

RC-20 TERMINATE ALL DISCONTINUOUS TOP BARS WITH STANDARD 90

AutoCAD SHX Text

RC-19 LAP CONTINUOUS REINF. AS NOTED IN LAP SPLICE SCHEDULE OR

AutoCAD SHX Text

ASTM STANDARDS REFERENCE IN ACI 318

AutoCAD SHX Text

RC-5 STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 SPECIFICATIONS

AutoCAD SHX Text

k) STRENGTH TEST DATA REQUIRED TO ESTABLISH MIX DESIGN

AutoCAD SHX Text

l) COMPLETE DETAIL AND PLACING SHOP DRAWINGS FOR ALL REINFORCING

AutoCAD SHX Text

STEEL INCLUDING ACCESSORIES THAT HAVE BEEN REVIEWED AND STAMPED

AutoCAD SHX Text

d) COARSE AND FINE AGGREGATE IN POUNDS/CUBIC YARD

AutoCAD SHX Text

a) INTENDED USAGE AND LOCATION FOR EACH TYPE

AutoCAD SHX Text

RC-10 SUBMIT COPIES OF CONCRETE MIX DESIGN TO ENGINEER FOR APPROVAL

AutoCAD SHX Text

RC-11 ALL REINFORCEMENT SHALL BE FASTENED AND SECURED TOGETHER

AutoCAD SHX Text

TO PREVENT DISPLACEMENT BY CONSTRUCTION LOADS OR THE PLACING

AutoCAD SHX Text

(NON-AIR ENTRAINED), 0.47 MAXIMUM (AIR ENTRAINED)

AutoCAD SHX Text

3000 PSI, 28 DAY COMPRESSIVE STRENGTH; W/C RATIO 0.58 MAXIMUM

AutoCAD SHX Text

RC-8 MAXIMUM WATER TO CEMENT RATIO WHEN NO BACK-UP DATA IS AVAILABLE:

AutoCAD SHX Text FOOTINGS 4"%%p1" ASTM #57

AutoCAD SHX Text %%ULOCATION SLUMP MAX. AGGREGATE%%u

AutoCAD SHX Text

RC-7 STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 AND HAVE THE

AutoCAD SHX Text

CEMENTITIOUS MATERIAL. DO NOT USE FOR EXPOSED SLABS

AutoCAD SHX Text

INSTALLED IN ACCORDANCE WITH ACI 318 AND ACI DETAILING

AutoCAD SHX Text

PLASTICIZER ADMIXTURE IF NECESSARY TO INCREASE SLUMPS

AutoCAD SHX Text

RANGE WATER REDUCING AGENT. MINIMUM SIZE OF DISCHARGE TO

AutoCAD SHX Text

RC-17 REINFORCEMENT WITH RUST, MILL SCALE OR A COMBINATION OF

AutoCAD SHX Text

RC-16 ALL REINFORCING STEEL SHALL BE DETAILED, FABRICATED AND

AutoCAD SHX Text

RC-14 A 2" I.D. DISCHARGE MAY BE USED WITH #8 AGGREGATE. USE

AutoCAD SHX Text

RC-13 ALL PUMPED CONCRETE WITH #57 AGGREGATE IS TO CONTAIN A HIGH

AutoCAD SHX Text

RC-12 THE USE OF JITTERBUGS TO CONSOLIDATE CONCRETE WILL NOT BE

AutoCAD SHX Text

RC-9 FLYASH, WHEN USED, SHALL BE LIMITED TO 20% OF THE

AutoCAD SHX Text

c) CEMENT CONTENT IN POUNDS-PER-CUBIC YARD

AutoCAD SHX Text

PERMITTED.

AutoCAD SHX Text

MANUAL, ACI-315 LATEST EDITION.

AutoCAD SHX Text

BEYOND THAT NOTED ABOVE.

AutoCAD SHX Text

BE 4" I.D.

AutoCAD SHX Text

i) ADMIXTURE TYPE AND MANUFACTURER

AutoCAD SHX Text

j) PERCENT ADMIXTURE BY WEIGHT

AutoCAD SHX Text

BY THE GENERAL CONTRACTOR

AutoCAD SHX Text

e) WATER CEMENT RATIO BY WEIGHT

AutoCAD SHX Text

f) CEMENT TYPE AND MANUFACTURER

AutoCAD SHX Text

OF CONCRETE

AutoCAD SHX Text

h) AIR CONTENT

AutoCAD SHX Text

g) SLUMP RANGE

AutoCAD SHX Text

RC-6 USE REGULAR WEIGHT CONCRETE.

AutoCAD SHX Text

b) MIX DESIGN FOR EACH TYPE

AutoCAD SHX Text

INFORMATION SHALL INCLUDE:

AutoCAD SHX Text

FOLLOWING SLUMPS & AGGREGATE REQUIREMENTS:

AutoCAD SHX Text

ACCORDANCE WITH THE ACI "BUILDING CODE REQUIREMENTS FOR

AutoCAD SHX Text

RC-2 PROVIDE (4) TEST CYLINDERS FOR EACH 50 C.Y. OF CONCRETE

AutoCAD SHX Text

RC-1 ALL CONCRETE DESIGN AND PLACEMENT SHALL BE IN STRICT

AutoCAD SHX Text

%%UREINFORCED CONCRETE

AutoCAD SHX Text

PLACED OR FRACTION THEREOF.

AutoCAD SHX Text

STRUCTURAL CONCRETE," ACI 318-LATEST EDITION.

AutoCAD SHX Text

LOCATION AND SIZE OF SLEEVES THROUGH BEAMS TO ENGINEER FOR

AutoCAD SHX Text

IN CONJUNCTION WITH REVIEWED SHOP DRAWINGS FOR PLACEMENT OF

AutoCAD SHX Text

RC-24 USE THE STRUCTURAL DRAWINGS INCLUDING REVISIONS AND ADDENDA

AutoCAD SHX Text

REVIEW PRIOR TO CASTING CONCRETE.

AutoCAD SHX Text

REINFORCING.

AutoCAD SHX Text

RC-22 SLEEVE ALL PENETRATIONS THROUGH BEAMS AND SLABS

AutoCAD SHX Text

RC-23 NO REINFORCING BARS SHALL BE CUT TO ACCOMMODATE THE

AutoCAD SHX Text

INSTALLATION OF ANCHORS, EMBEDS OR OTHER ITEMS.

AutoCAD SHX Text

INDIVIDUALLY. CORE DRILLING WILL NOT BE PERMITTED. SUBMIT

AutoCAD SHX Text

RC-25 AT CHANGES IN DIRECTION OF CONCRETE WALLS, BEAMS & STRIP

AutoCAD SHX Text

FOOTINGS, PROVIDE CORNER BARS OF SAME SIZE AND QUANTITY

AutoCAD SHX Text

UNLESS NOTED OTHERWISE AS HORIZONTAL STEEL.

AutoCAD SHX Text

b) LOCATION OF ANY CONSTRUCTION JOINT NOT SHOWN IS SUBJECT

AutoCAD SHX Text

RC-27 THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FOR PROVIDING THE

AutoCAD SHX Text

RC-26 ALL EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE PRIOR TO

AutoCAD SHX Text

MATERIAL SHALL BE REMOVED FROM EXCAVATION BEFORE AND DURING

AutoCAD SHX Text

RC-31 PLACEMENT OF CONDUIT AND PIPES IN CONCRETE SHALL CONFORM TO

AutoCAD SHX Text

RC-30 FOOTING SIZES SHOWN ARE FOR FOOTINGS CONSTRUCTED WITH SIDE

AutoCAD SHX Text

TO REVIEW AND ACCEPTANCE BY ENGINEER,

AutoCAD SHX Text

RC-32 CONSTRUCTION JOINTS NOT SHOWN ON THE DRAWINGS MUST BE

AutoCAD SHX Text

AND LOCATED TO LEAST IMPAIR THE STRENGTH OF THE STRUCTURE.

AutoCAD SHX Text

a) NO HORIZONTAL CONSTRUCTION JOINTS WILL BE PERMITTED IN

AutoCAD SHX Text

ACI 318, SECTION 6.3.

AutoCAD SHX Text

PLACEMENT OF CONCRETE.

AutoCAD SHX Text

FORMS. IF SOIL MATERIAL CAN HOLD A VERTICAL SHAPE, IT CAN

AutoCAD SHX Text

INCREASED 1" IN EACH HORIZONTAL DIRECTION. ALL SLOUGHED

AutoCAD SHX Text

BE USED AS AN EARTH FORM PROVIDED FOOTING WIDTH IS

AutoCAD SHX Text

SEGREGATION OF CONCRETE DURING PLACEMENT.

AutoCAD SHX Text

AGGREGATE. ALL PRECAUTIONS SHOULD BE TAKEN TO AVOID

AutoCAD SHX Text

OF CONCRETE TO 6'-0" FOR #57 AGGREGATE AND 8'-0" FOR #8

AutoCAD SHX Text

VIBRATION FOR ALL CONCRETE. LIMIT MAXIMUM FREE FALL DROP

AutoCAD SHX Text

RC-29 PLACE CONCRETE PER ACI 304. USE INTERNAL MECHANICAL

AutoCAD SHX Text

CONSTRUCTION OF ALL FORMWORK IN ACCORDANCE WITH ACI 347.

AutoCAD SHX Text

CONCRETE PLACEMENT.

AutoCAD SHX Text

#3 STIRRUPS @ 18" OC

AutoCAD SHX Text

D-1 CODES: 2023 FLORIDA BUILDING CODE, BUILDING

AutoCAD SHX Text NOMINAL DESIGN WIND SPEED, Vasd: 124 MPH (3 SECOND GUST)

AutoCAD SHX Text

D-5 FLOOD DESIGN DATA: ZONES 'X'

AutoCAD SHX Text

RISK CATEGORY: II

AutoCAD SHX Text

b. (1) COURSE 8" BEAM BLOCK REINF W/ #5 FULLY

AutoCAD SHX Text

GROUTED EA COURSE

AutoCAD SHX Text

AND SHALL DEVELOP THE FOLLOWING MINIMUM COMPRESSIVE

AutoCAD SHX Text

RC-3 STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 SPECIFICATIONS

AutoCAD SHX Text

STRENGTH AT 28 DAYS:

AutoCAD SHX Text

ALL OTHER CONCRETE 3000 PSI

AutoCAD SHX Text

SPREAD AND WALL FOOTINGS 3000 PSI

AutoCAD SHX Text

FREE STANDING FENCE

AutoCAD SHX Text

SOLIDITY: 13.7%%%

AutoCAD SHX Text

WHICH DISTURBS THE COMPACTED SOIL BENEATH THE FOOTINGS/

AutoCAD SHX Text

SF-6 REINFORCING SHALL BE SUPPORTED ON PRECUTS CONCRETE PADS.

AutoCAD SHX Text

FOUNDATIONS WILL NOT BE PERMITTED.

AutoCAD SHX Text

DOWELS FOR COLUMNS AND FILLED CELLS SHALL BE SECURED IN

AutoCAD SHX Text

PLACE PRIOR TO POURING CONCRETE. USE TEMPLATES FOR SETTING

AutoCAD SHX Text

SF-5 EXCAVATING UNDER OR NEAR IN-PLACE FOOTINGS/FOUNDATIONS

AutoCAD SHX Text

SF-1

AutoCAD SHX Text

SF-4 COORDINATE PLUMBING LINES WITH FOOTING LOCATIONS FOR

AutoCAD SHX Text

SF-3 HORIZONTAL JOINTS IN FOOTINGS WILL NOT BE PERMITTED.

AutoCAD SHX Text

SF-2 CENTER ALL FOOTINGS UNDER THEIR RESPECTIVE COLUMNS OR WALLS

AutoCAD SHX Text

%%USHALLOW FOUNDATIONS

AutoCAD SHX Text

WALL FOOTINGS SHOULD BE STEPPED AS DETAILED ON THE

AutoCAD SHX Text

THE PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. CONTINUOUS

AutoCAD SHX Text

INTERFERENCE. INDIVIDUAL FOOTINGS CAN BE LOWERED WITH

AutoCAD SHX Text

DOWELS OR ANCHOR BOLTS TO BE PER ACI OR AISC STANDARDS.

AutoCAD SHX Text

ECCENTRICITY - 2". TOLERANCE FOR MISLOCATION OF COLUMN

AutoCAD SHX Text

UNLESS OTHERWISE SHOWN ON PLANS. MAXIMUM MISPLACEMENT OR

AutoCAD SHX Text

SOIL TO BE STRIPPED, COMPACTED AND TESTED IN ACCORDANCE WITH

AutoCAD SHX Text

THE RECOMMENDATIONS OF THE SOILS ENGINEER AND PROJECT

AutoCAD SHX Text

DRAWINGS.

AutoCAD SHX Text

SPECIFICATIONS.

AutoCAD SHX Text

COLUMN DOWELS AND ANCHOR BOLTS.

AutoCAD SHX Text THE DRAWINGS ARE THE PROPERTY OF THE ENGINEER. WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. COPY OR USE FOR OTHER PROJECTS IS PERMITTED ONLY BY WRITTEN CONTRACT WITH THE ENGINEER. UNAUTHORIZED USE WILL BE PROSECUTED PURSUANT TO THE COPYRIGHT LAWS.

AutoCAD SHX Text

CIVIL & STRUCTURAL ENGINEERING LAND PLANNING ENVIRONMENTAL PERMITTING

AutoCAD SHX Text

CERTIFICATION OF AUTHORIZATION NO.: 00008668

AutoCAD SHX Text 24-095

AutoCAD SHX Text

CITY OF SEBASTIAN

AutoCAD SHX Text

SPORTS COMPLEX

AutoCAD SHX Text

SEBASTIAN, FLORIDA

AutoCAD SHX Text C-4

SPECIFICATIONS & STRUCTURAL DETAILS BASEBALL BACKSTOPS BARBER STREET SPORT COMPLEX

Sheets and Views
C-1
Sheets and Views
C-2
Sheets and Views
C-3
Sheets and Views
C-4
2024-10-01T12:25:32-0700
Digitally verifiable PDF exported from www.docusign.com

File details come from the government source that posted it. Updated .