Construction Documents Summary: Holladay Lions Recreation Center RTU Replacement
This is a comprehensive set of construction documents for a state and local contract opportunity in Salt Lake County, Utah, detailing the replacement of rooftop air handling units (RTUs) at the Holladay Lions Recreation Center located at 1661 E Murray Holladay Road, Millcreek, UT 84117. The project scope includes demolition and replacement of existing RTUs across multiple roof sections (Roofs A, B, C, and D), installation of new ductwork, mechanical systems, plumbing connections, gas piping, electrical systems, and associated roofing modifications. The construction documents consist of architectural plans showing overall roof layouts, demolition plans, and new installation plans; mechanical drawings detailing HVAC system components, ductwork routing, equipment schedules specifying nine rooftop units ranging from 3 to 12.5 tons with York brand units, condensate pumps, and a humidifier; and electrical plans showing power distribution, disconnect switches, and circuit requirements. The project involves coordinated work with a separate re-roofing project and includes a bid alternate option for certain equipment selections. Construction documents are dated March 18, 2026, with professional engineers and consultants from HHY Associates providing design oversight.
The mechanical equipment schedule specifies multiple York packaged rooftop units with two-stage natural gas heating, cooling capacities ranging from 3 to 12.5 tons, R454B refrigerant, and BACnet/MSTP controls, all sized for high-altitude operation at 4,500 feet. The electrical scope requires coordination of new circuits, disconnects, and breaker installations to existing panels, with all new equipment to be connected to dedicated or existing circuits and all conduit to be concealed behind equipment curbs or within building structure per National Electrical Code standards. Project coordination is critical among mechanical, electrical, plumbing, and structural trades, with the contractor responsible for field verification of existing conditions, protection of systems remaining in place, water control during construction, and comprehensive system testing and commissioning upon completion. The documents establish that contractors must visit the site, coordinate with all trades, maintain proper service clearances, provide updated panel schedules and circuit documentation, and ensure all systems operate as complete, functional installations with one-year material and workmanship guarantees.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1661 E MURRAY HOLLADAY RD
MILLCREEK, UT 84117
REQUEST #
MARCH 18, 2026
CONSTRUCTION DOCUMENTS
HOLLADAY LIONS
RECREATION CENTER
ROOF TOP UNIT REPLACEMENT
DRAWING INDEX
SYMBOL LEGENDVICINITY MAP
ABBREVIATIONS
FLUE
FH
VTR
EX
RTU
GA
VENT
OWNERCONSULTANTS
BID INFORMATION
9 11 18 6 mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
A Y
L
I O
N S
R
E C
R E
A T
I O
N
C
E N
T E
R
R O
O F
T
P
U
P
L A
C E
M E
N T
M
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
SITE PLAN &
GENERAL NOTES
A0.1
A B C D
ROOF
A
ROOF
B
ROOF
D
ROOF
C mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
OVERALL
ROOF PLAN &
CODE ANALYSIS
A1.0
CODE ANALYSIS
Occupant Loads:
2001 Building: 2008 Addition:
Pool 374 Gymnasium 10,810/50 217 Fitness 57 Running Track 3,590/50 72 Aerobics 30 Multi-Purpose 3,251/50 66 Office 6 Day Care 1,098/35 32 Lockers 37 Office 1,202/100 13 Mechanical 7 Conference 294/15 20
Pool Classroom 696/20 35 Total 511 Total 455
ELEVATION 120'-0"
T.O. CMU
SL
OP
E 1/
4"
/FT
M
IN
. SL
OP
E 1/
4"
/FT
T
YP
ELEVATION 120'-0"
T.O. EXISTING CMU
T.O. CMU
ELEVATION 138'-0"
T.O. CMU
ELEVATION 141'-4"
T.O. CMU
ELEVATION 138'-0"
T.O. CMU
ELEVATION 138'-0"
T.O. CMU
ELEVATION 138'-0"
T.O. CMU
ELEVATION 141'-4"
T.O. CURB
ELEVATION 118'-0"
T.O. CURB
ELEVATION 118'-0"
ELEVATION 120'-8"
T.O. CONCRET
mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
ROOF A -
DEMOLITION PLAN
A1.1D
ELEVATION 120'-3"
DECK BEARING
ELEVATION 121'-4"
T.O. CMU
ELEVATION 115'-4"
DECK BEARING
ELEVATION 120'-8"
T.O. CONCRETE
ELEVATION 120'-0"
T.O. CMU
ELEVATION 120'-0"
T.O. CMU
ELEVATION 120'-0"
T.O. CMU
ELEVATION 119'-0"
DECK BEARING
ELEVATION 115'-4"
DECK BEARING
ELEVATION 134'-0"
DECK BEARING
ELEVATION 134'-8"
T.O. CMU
ELEVATION 131'-8"
DECK BEARING
ELEVATION 134'-8"
T.O. CMU
ELEVATION 131'-8"
DECK BEARING
ELEVATION 134'-8"
T.O. CMU
ELEVATION 116'-0"
ELEVATION 118'-0"
T.O. CMU
DECK BEARING
ELEVATION 120'-8"
T.O. CONCRETE
ELEVATION 120'-0"
T.O. CMU
ELEVATION 134'-8"
T.O. CMU
SL
OP
E 1/
4"
/FT
. M
IN
SLOPE 1/4"/FT. MIN.SLOPE 1/4"/FT. MIN.SLOPE 1/4"/FT. MIN.
SL
OP
E 1/
4"
/FT
. M
IN
SL
OP
E 1/
4"
/FT
. T
YP
SL
OP
E
1/ 4"
/FT
. T
YP
SL
OP
E 1/
4"
/FT
. M
IN
SL
OP
E
1/ 4"
/FT
. M
IN
SL
OP
E 1/
4"
/FT
. M
IN
SL
OP
E 1/
4"
/FT
M
IN
SLOPE 1/4"/FT. MIN.SLOPE 1/4"/FT. MIN.
SL
OP
E 1/
4"
/FT
. M
IN
SL
OP
E
1/ 4"
/FT
. M
IN
SL
OP
E 1/
4"
/FT
T
YP
SLOPE 1/4"/FT MIN.
SLOPE 1/4"/FT MIN.
SLOPE 1/4"/FT MIN.
SL
OP
E 1/
4"
/FT
M
IN
SLOPE
1/4"/FT MIN.
SL
OP
E 1/
4"
/FT
M
IN
. SL
OP
E 1/
4"
/FT
T
YP
ELEVATION 124'-0"
T.O. EIFS
ELEVATION 116'-8"
T.O. STUD WALL
ELEVATION 120'-0"
T.O. EXISTING CMU
ELEVATION 116'-2"±
DECK BEARING
(MATCH EXISTING)
ELEVATION 120'-0"
T.O. CMU
ELEVATION 120'-3"
BEACK BEARING
ELEVATION 118'-0"
T.O. STUD WALL
ELEVATION 118'-0"
T.O. EXIST. CMU
ELEVATION 133'-0"
DECK BEARINGELEVATION 134'-8"
T.O. CMU
ELEVATION 118'-0"
T.O. EXIST. CMU
ELEVATION 115'-9"±
DECK BEARING
(MATCH EXISTING)
T.O. CMU
ELEVATION 138'-0"
T.O. CURB
ELEVATION 118'-0"
ELEVATION 121'-4"
T.O. CMU
T.O. CURB
ELEVATION 118'-0"
VTR
VTR
VTR
T.O. CURB
ELEVATION 118'-0"
ELEVATION 120'-8"
T.O. CONCRET
T.O. CMU
ELVATION 118'-0"
T.O. CMU
ELEVATION 120'-0"
SL
OP
E 1/
4"
/FT
M
IN
SLOPE
1/4"/FT MIN.
mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
ROOF B, C & D
- DEMOLITION PLAN
A1.2D
ELEVATION 120'-0"
SL
OP
E 1/
4"
/FT
M
IN
. SL
OP
E 1/
4"
/FT
T
YP
ELEVATION 120'-0"
T.O. EXISTING CMU
T.O. CMU
ELEVATION 138'-0"
T.O. CMU
ELEVATION 141'-4"
T.O. CMU
ELEVATION 138'-0"
T.O. CMU
ELEVATION 138'-0"
T.O. CMU
ELEVATION 138'-0"
T.O. CMU
ELEVATION 141'-4"
T.O. CURB
ELEVATION 118'-0"
T.O. CURB
ELEVATION 118'-0"
ELEVATION 120'-8"
T.O. CONCRET
mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
ROOF A
- NEW PLAN
A1.1N
ELEVATION 120'-3"
DECK BEARING
ELEVATION 121'-4"
T.O. CMU
ELEVATION 115'-4"
DECK BEARING
ELEVATION 120'-8"
T.O. CONCRETE
ELEVATION 120'-0"
T.O. CMU
ELEVATION 120'-0"
T.O. CMU
ELEVATION 120'-0"
T.O. CMU
ELEVATION 119'-0"
DECK BEARING
ELEVATION 115'-4"
DECK BEARING
ELEVATION 134'-0"
DECK BEARING
ELEVATION 134'-8"
T.O. CMU
ELEVATION 131'-8"
DECK BEARING
ELEVATION 134'-8"
T.O. CMU
ELEVATION 131'-8"
DECK BEARING
ELEVATION 134'-8"
T.O. CMU
ELEVATION 116'-0"
ELEVATION 118'-0"
T.O. CMU
DECK BEARING
ELEVATION 120'-8"
T.O. CONCRETE
ELEVATION 120'-0"
T.O. CMU
ELEVATION 134'-8"
T.O. CMU
SL
OP
E 1/
4"
/FT
. M
IN
SLOPE 1/4"/FT. MIN.SLOPE 1/4"/FT. MIN.SLOPE 1/4"/FT. MIN.
SL
OP
E 1/
4"
/FT
. M
IN
SL
OP
E 1/
4"
/FT
. T
YP
SL
OP
E
1/ 4"
/FT
. T
YP
SL
OP
E 1/
4"
/FT
. M
IN
SL
OP
E
1/ 4"
/FT
. M
IN
SL
OP
E 1/
4"
/FT
. M
IN
SL
OP
E 1/
4"
/FT
M
IN
SLOPE 1/4"/FT. MIN.SLOPE 1/4"/FT. MIN.
SL
OP
E 1/
4"
/FT
. M
IN
SL
OP
E
1/ 4"
/FT
. M
IN
SL
OP
E 1/
4"
/FT
T
YP
SLOPE 1/4"/FT MIN.
SLOPE 1/4"/FT MIN.
SLOPE 1/4"/FT MIN.
SL
OP
E 1/
4"
/FT
M
IN
SLOPE
1/4"/FT MIN.
SL
OP
E 1/
4"
/FT
M
IN
. SL
OP
E 1/
4"
/FT
T
YP
ELEVATION 124'-0"
T.O. EIFS
ELEVATION 116'-8"
T.O. STUD WALL
ELEVATION 120'-0"
T.O. EXISTING CMU
ELEVATION 116'-2"±
DECK BEARING
(MATCH EXISTING)
ELEVATION 120'-0"
T.O. CMU
ELEVATION 120'-3"
BEACK BEARING
ELEVATION 118'-0"
T.O. STUD WALL
ELEVATION 118'-0"
T.O. EXIST. CMU
ELEVATION 133'-0"
DECK BEARINGELEVATION 134'-8"
T.O. CMU
ELEVATION 118'-0"
T.O. EXIST. CMU
ELEVATION 115'-9"±
DECK BEARING
(MATCH EXISTING)
T.O. CMU
ELEVATION 138'-0"
T.O. CURB
ELEVATION 118'-0"
ELEVATION 121'-4"
T.O. CMU
T.O. CURB
ELEVATION 118'-0"
VTR
VTR
VTR
T.O. CURB
ELEVATION 118'-0"
ELEVATION 120'-8"
T.O. CONCRET
T.O. CMU
ELVATION 118'-0"
T.O. CMU
ELEVATION 120'-0"
SL
OP
E 1/
4"
/FT
M
IN
SLOPE
1/4"/FT MIN.
mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
ROOF B, C & D
- NEW PLAN
A1.2N
C1 9'-0"
C1 9'-0"
C110'-0"
C2 9'-0"
C4 EXIST
C1 9'-0"
C1 9'-0"
C214'-0"
C112'-0"
C2 9'-0"
C3 OTS
C5 EXIST
C3 OTS
C110'-0"
C110'-0"
C4 EXIST
VESTIBULE
ENTRY
OFFICE
STORAGE
ELECTRICAL
RECEPTION
CLASSROOM
STORAGE
LOBBY
RESTROOM
110 CHILD CARE
CORRIDOR
CORRIDOR
CORRIDOR
ELECTRICAL
OFFICE
C5 EXIST
C1 9'-0"
C4 EXIST
C5 EXIST
OFFICE
C110'-0"
C110'-0"
8'-4" 4'-11" 4"
4" 4'-
8" 1'-
0" 7'-
7" 7'-
6'-
1 2"
'-1
4'-11"4'-0"6'-4" 4"
C4 EXIST
C4 EXIST
C3VARIES
C411'-8" mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
REFLECTED
CEILING PLAN
- SOUTH
A1.3S
X 10'-0"
UP
C1 9'-0"
C1 9'-0"
C110'-0"
C2 9'-0"
C4 EXIST
C1 9'-0"
C1 9'-0"
C214'-0"
C112'-0"
C2 9'-0"
C3 OTS
C110'-0"
C112'-0"
C1 9'-0"C1 9'-0"C1 9'-0"
C2 9'-0"
C2 9'-0"
C114'-0"
C5 EXIST
C3 OTS
C3 OTS
C110'-0"
C110'-0"
C4 EXIST
VESTIBULE
ENTRY
OFFICE
STORAGE
ELECTRICAL
RECEPTION
CLASSROOM
STORAGE
LOBBY
RESTROOM
110 CHILD CARE
CORRIDOR
CORRIDOR
CONFERENCE
OFFICE
OFFICE
STORAGE
STORAGE
OFFICE
RESTROOM
RESTROOM
ELEVATOR
EQUIPMENT
MULTI-PURPOSE
CORRIDOR
CORRIDOR
ELECTRICAL
STORAGE
OFFICE
C5 EXIST
C1 9'-0"
C4 EXIST
C5 EXIST
C1 9'-0"C1 9'-0"
C3 OTS
OFFICE
C110'-0"
C110'-0"
8'-4" 4'-11" 4"
4" 4'-
8" 1'-
0" 7'-
7" 7'-
6'-
1 2"
'-1
4'-11"4'-0"6'-4" 4"
C4 EXIST
C2VARIES
C4 EXIST
C3VARIES
C3VARIES
97'-6"
18'-0"
LOBBY
C411'-8" mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
REFLECTED
CEILING DEMO
PLAN - NORTH
A1.3N
C1 9'-0"
C1 9'-0"
C110'-0"
C2 9'-0"
C4 EXIST
C1 9'-0"
C1 9'-0"
C214'-0"
C112'-0"
C2 9'-0"
C3 OTS
C110'-0"
C112'-0"
C1 9'-0"C1 9'-0"C1 9'-0"
C2 9'-0"
C2 9'-0"
C114'-0"
C5 EXIST
C3 OTS
C3 OTS
C110'-0"
C110'-0"
C4 EXIST
VESTIBULE
ENTRY
OFFICE
STORAGE
ELECTRICAL
RECEPTION
CLASSROOM
STORAGE
LOBBY
RESTROOM
110 CHILD CARE
CORRIDOR
CORRIDOR
CONFERENCE
OFFICE
OFFICE
STORAGE
STORAGE
OFFICE
RESTROOM
RESTROOM
ELEVATOR
EQUIPMENT
MULTI-PURPOSE
CORRIDOR
CORRIDOR
ELECTRICAL
STORAGE
OFFICE
C5 EXIST
C1 9'-0"
C4 EXIST
C5 EXIST
C1 9'-0"C1 9'-0"
C3 OTS
OFFICE
C110'-0"
C110'-0"
8'-4" 4'-11" 4"
4" 4'-
8" 1'-
0" 7'-
7" 7'-
6'-
1 2"
'-1
4'-11"4'-0"6'-4" 4"
C4 EXIST
C2VARIES
C4 EXIST
C3VARIES
C3VARIES
97'-6"
18'-0"
LOBBY
C411'-8" mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
REFLECTED
CEILING REMODEL
PLAN - NORTH
A1.4N
A B C D mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
ROOF FRAMING
PLAN
A1.5
FIN. FLOOR
EL. 100'-0"
EL. 138'-0"
T.O.M.
LOBBY
CLASSROOM
STORAGE
OFFICE
EXIST
EXISTING CMU WALL
EXISTING CMU WALL
NEW CMU WALL
EXISTING
TPO
ROOFING
T/MASONRY
EL. 138'-0"
T/MASONRY
EL. 141'-4"
MTL ROOF DECK
40 LH12 @ 5'-6" O/C
LOBBY
CORRIDOR
ELEVATOR
EQUIPMENT
MULTI-PURPOSE
2 1346
ELEVATION 134'-8"
T.O. CMU
ELEVATION 121'-4"
T.O. CMU
ELEVATION 100'-0"
FINISHED FLOOR
VENDING
EXISTING CMU WALL
NEW CMU WALL
PRE FINISHED METAL
COPING
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION
OVER METAL DECKING
A2.2
A A2.2
E
20 GA 1 1/2" TYPE 'B' MTL
ROOF DECK
44 LH10
40 LH12 @ 5'-6" O/C
'-0 mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
BUILDING
SECTIONS
A2.1
ELEVATION 134'-8"
ELEVATION 114'-0"
T.O. TRACK
ELEVATION 131'-8"
DECK BEARING
ELEVATION 100'-0"
FINISHED FLOOR
ELEVATION 116'-0"
DECK BEARING
ELEVATION 118'-0"
T.O. CMU
T.O. CMU
'-0
'-0
'-0
ABCD
GYMNASIUM
CORRIDOR
CONFERENCE
OFFICE
OFFICE
OFFICE
RESTROOM
ELEVATION 116'-8"
DECK BEARING
ELEVATION 120'-8"
T.O. CONCRETE WALL
ELEVATION 134'-8"
T.O. CMU
ELEVATION 116'-8"
DECK BEARING
ELEVATION 133'-6"
DECK BEARING
NEW CMU SHEAR WALLEXISTING WINDOW W/
NEW SAFETY GLASS AS
SCHEDULED
EXISTING CMU WALL.
PAINT TO MACH NEW WALL
NEW PRE-CAST BENCH
ELEVATION 124'-"
T.O. CMU WALL
STORAGE
PRE FINISHED METAL
COPING
PAINTED JOIST
EIFS WALL
METAL CANOPY
A2.2
D
A2.1
C A2.2
B
A2.2
C
20 GA 1 1/2" TYPE 'B' MTL
ROOF DECK MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION
OVER METAL DECKING
56/70/56 DLH14 W/ (6)
ROWS OF XB
MTL ROOF DECK
W10x12
MTL ROOF
DECK
W8x10
67 3 145
CORRIDOR
STORAGE
OFFICE
MULTI-PURPOSE
LOBBY
ELEVATION 121'-4"
T.O. CMU
ELEVATION 100'-0"
FINISHED FLOOR
ELEVATION 134'-8"
T.O. CMU
B C
ELEVATION 121'-4"
T.O. CMU
MULTI-PURPOSE
GYMNASIUM
ELEVATION 134'-8"
T.O. CMU
ELEVATION 100'-0"
FINISHED FLOOR
ELEVATION 131'-8"
DECK BEARING
PRE FINISHED
METAL COPING
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION
OVER METAL DECKING
EXPANSION
COVER
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION
OVER METAL DECKING
A2.2
E
A2.2
D
A2.2
A
'-0
EXISTING TPO
ROOFING
20 GA 1 1/2" TYPE 'B' MTL
ROOF DECK
44 LH10
20 GA 1 1/2" TYPE 'B' MTL
ROOF DECK
44 LH10
MTL ROOF DECK
28 LH06 @ 5'-0" O/C
MTL ROOF DECK
W10x12
MTL ROOF DECK
40 LH12 @ 5'-6" O/C
'-1
113 16
'-31 8"
'-0
'-8
ELEVATION 134'-8"
T.O. CMU
ELEVATION 114'-0"
T.O. CMU
ELEVATION 100'-0"
FINISHED FLOOR
LOBBY
GYMNASIUM
CHILD CARE
STORAGE
OFFICE
ENTRY
78 6
2 PERIOD
GUEST HOME
0:36
PRE-CAST BENCH
PRE FINISHED
METAL COPING
PRE FINISHED
METAL COPING
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION
OVER METAL DECKING
EXISTING CMU WALL
EXISTING CMU WALL
A2.2
A
'-0
'-0
'-8
9 16
'-1
13 16
EXISTING TPO
ROOFING
EXISTING TPO
ROOFINGEXISTING TPO
ROOFING
EXIST EIFS
WALL
20 GA 1 1/2" TYPE 'B' MTL
ROOF DECK
56/70/56 DLH14 W/ (6)
ROWS OF XB
MTL ROOF DECK
W10x12 @ 7'-0" O/C
MTL ROOF DECK
W12x19 @ 7'-0" O/C mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
BUILDING
SECTIONS
A2.2
ELEVATION 124'-0"
EIFS OVER 2" RIGID INSULATION
OVER 8" CMU WALL
TUBE STEEL
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION
OVER METAL DECKING
SLOPE
SLOPE
ELEVATION 100'-0"
FINISHED FLOOR
ELEVATION 116'-8"
DECK BEARING
ELEVATION 124'-0"
T.O. CMU
EIFS OVER 2" RIGID INSULATION
OVER 8" CMU WALL
BASE AS SCHED.
4" CONCRETE SLAB
ON GRADE OVER 4"
DRAINAGE FILL
EIFS OVER 2" RIGID
INSULATION OVER
8" CMU WALL
PAINTED HOLLOW METAL
WINDOW FRAME
GLAZING AS SCHEDULED
CEILING AS SCHEDULED
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION OVER
METAL DECKING
6" M
IN
COMPACTED STRUCTURAL
FILL OR UNDISTURBED
NATURAL SOIL. TYP.
ENTRY
CHILD CARE
PAINTED 8" CMU
CONC. FOOTING AND
FOUNDATION
MTL ROOF DECK
W10x12 @ 7'-0" O/C
MTL ROOF DECK
W12x19 @ 7'-0" O/C
MTL ROOF DECK
W12x14
ELEVATION 100'-0"
FINISHED FLOOR
ELEVATION 116'-8"
T.O. STUD/ FRAME
ELEVATION 111'-8"
T.O. CANOPY
CONC. FOOTING AND
FOUNDATION
CEILING AS SCHEDULED
4" CONCRETE SLAB
ON GRADE OVER 4"
DRAINAGE FILL
COMPOSITE METAL
PANEL SYSTEM OVER
5/8" SHEATHING ON
METAL STUD FRAMING
GLAZING & FRAME AS SCHEDULED
COMPOSITE METAL PANEL SYSTEM
OVER 5/8" EXTERIOR SHEATHING
ON METAL STUD FRAMING
PRE FINISHED METAL
COPING
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
RIGID INSULATION OVER
METAL DECKING
GLAZING & FRAME AS SCHEDULED
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION OVER
METAL DECKING
5/8" PAINTED GYP. BD.
CEILING
TUBE STEEL
COMPACTED STRUCTURAL
FILL OR UNDISTURBED
NATURAL SOIL. TYP.
COMPOSITE METAL PANEL SYSTEM
2" FOUNDATION INSULATION
ARCHITECTURAL CONC.
FOUNDATION.
VESTIBULE
PAINTED STEEL COLUMN
SLOPE
SLOPE
A2.4
A
W14x22 mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
BUILDING
SECTION
A2.3
EIFS OVER 2" RIGID INSULATION
OVER 8" CMU WALL
ELEVATION 100'-0"
FINISHED FLOOR
ELEVATION 111'-8"
T.O. CANOPY
D
ELEVATION 116'-8"
T.O. STUD/ FRAME
ELEVATION 120'-8"
T.O. CONCRETE WALL
ELEVATION 124'-0"
T.O. CMU
PUNCHED OPENINGS IN EIFS WALL
8" CONCRETE WALL
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION OVER
METAL DECKING
COMPOSITE METAL PANEL SYSTEM
OVER 5/8" EXTERIOR SHEATHING
ON METAL STUD FRAMING
GLAZING & FRAME AS SCHEDULED
PRE FINISHED METAL
COPING
CONC. FOOTING AND
FOUNDATION
GLAZING & FRAME AS SCHEDULED
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
RIGID INSULATION OVER
METAL DECKING
COMPOSITE METAL
PANEL SYSTEM OVER
5/8" SHEATHING ON
METAL STUD FRAMING
TUBE STEEL. SEE
STRUCT.
PAINTED HOLLOW METAL
WINDOW FRAME
4" CONCRETE SLAB ON GRADE OVER 4"
DRAINAGE FILL
CEILING AS SCHEDULED
MECHANICALLY FASTENED
SINGLE-PLY ROOFING OVER
R-30 RIGID INSULATION OVER
METAL DECKING
PRE FINISHED METAL
COPING
EIFS REVEAL
TYP.
EIFS REVEAL
TYP.
1'- 0"
4"4'-11"
4"
EXISTING SLAB ON GRADE
COMPACTED STRUCTURAL FILL
OR UNDISTURBED NATURAL SOIL.
TYP.
EXISTING CONC.
SLAB FOOTING AND
FOUNDATION
SINGLE PLY ROOF
MEMBRANE TO EXTEND
UP PARAPET AND OVER
TOP OF PT. WOOD NAILER
2" FOUNDATION
INSULATION
VESTIBULE
ENTRY
SLOPE
4'- 8"
1'- 8"
1'- 0"
1'-4" 6'-6" 3'-8" 6'-4" 3'-8" 6'-4" 3'-8"
4'-0"6'-4"5'-03 16"6'-4"3'-8"6'-4"3'-8"
3'- 0"
2'- 0"
2'- 0"
4'- 8"
2'- 0"
2'- 0"
4'- 8"
2'- 4"
1'- 0"
6'-4"
A2.3
A
SURFACE MTD. REGLET,
TYP.
W10x12 @ 7'-0" O/C
W14x22 mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
BUILDING
SECTION
A2.4
≤ 8 mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
DETAILS
A3.1 mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210
2180 South 1300 East
Phone: 801 466 3996
H O
L L
A D
O
C
R E
A T
I O
N
C
E N
T E
R
R O
P
L A
C E
M E
N T
R
R A
Y
H
O L
L A
D A
Y
R
D
M
I L
L C
R E
E K
U
T
DETAILS
A3.2
Fax: 801 466 6022
Suite 210 2180 South 1300 East
Phone: 801 466 3996
H O
LL
AD
AY
L
IO
N
S R
EC
R
EA
TI
O N
C
EN
TE
R
R O
O F
TO
P
U N
IT
R
EP
LA
C
EM
EN
T
E M
U R
R
AY
H O
LL
AD
AY
R
D , M
IL
LC
R
EE
K, U
T
181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com
Project #: 260048
L
IC
EN
SE
D P
ROFESS I ONAL ENG
IN
E
ER
No. 4775391-2202
S TA T E O F U TAH
SPENCER W.
HOWELL
MECHANICAL
LEGEND, SYMBOLS,
& ABBREVIATIONS
M0.1
VTR
PS
N
LB/HR.GPM
3-1" SLOTS
@ 48" 400
W R
12/12
45°D
FD
FSD
SD
OR
8/8
1.25D
AD
LEGEND OF MECHANICAL SYMBOLS AND ABBREVIATIONS
12/8 FO
ATC
LATERAL STRAINER WITH BLOW-OFF VALVE, PROVIDE
HOSE END WITH CAP WHERE DISCHARGE IS NOT PIPED
TO DRAIN
F&T
(NAME)
R
12X12
22X22
12X12
24X10
24X10
12X12
12X12
SINGLE DUCT AIR TERMINAL BOX VARIABLE OR
CONSTANT VOLUME. MIN. 1-1/2 TERMINAL INLET SIZE
STRAIGHT DUCT AT TERMINAL INLET.
HEATING OR COOLING COIL IN DUCT
ACCESS PANEL IN DUCT OR PLENUM
ATC DAMPER
SMOKE DAMPER W/ ACCESS PANEL
COMBINATION FIRE/SMOKE DAMPER W/ ACCESS PANEL
FIRE DAMPER IN DUCT, W/ ACCESS PANEL REQD.
MANUAL VOLUME DAMPER
HIGH EFFICIENCY FITTING
TAP ENTRY AREA EQUALS 150% OF BRANCH AREA
BRANCH DUCT SPLIT WITH 6" WIDTH AND MIN.
R=WIDTH OF BRANCH DUCT DOWNSTREAM. ELBOW
TURNING VANE OPTIONAL.
RECTANGULAR TO ROUND DUCT TRANSFORMATION
RECTANGULAR TO RECTANGULAR OR ROUND TO ROUND
DUCT TRANSFORMATION MAXIMUM 15° INCLUDED ANGLE
EXCEPT WHERE SHOWN OTHERWISE.
R/W=1. ROUND DUCT SIMILAR TO RECTANGULAR
INCLINED DROP
INCLINED RISE WITH RESPECT TO AIR FLOW 15°
NOMINAL INCLINE WITH RADIUS
TURNS=DEPTH OF DUCT.
ROUND DUCT WITH FREE AREA DIMENSIONS
SHOWN IN INCHES.
RECTANGULAR DUCT WITH FREE AREA
DIMENSIONS SHOWN IN INCHES.
FLAT OVAL DUCT WITH FREE AREA
DIMENSIONS SHOWN IN INCHES.
FAN
FLEXIBLE DUCT
FLEXIBLE DUCT CONNECTION
LINEAR DIFFUSER WITH PLENUM AND FLEXIBLE DUCT
CONNECTION. NO. OF SLOTS & SIZE OF SLOT ON TOP, ACTIVE
LENGTH AND CFM ON BOTTOM
CEILING AIR GRILLE WITH
FLEXIBLE DUCT
CEILING SUPPLY DIFFUSER
WITH FLEXIBLE DUCT
SIDEWALL EXHAUST OR
RETURN REGISTER
SIDEWALL SUPPLY REGISTER
CEILING EXHAUST REGISTER,
(BALANCE TO MATCH SUPPLY IF
RETURN CFM IS NOT SHOWN)
CEILING RETURN REGISTER
CEILING SUPPLY DIFFUSER
RELIEF AIR OR EXHAUST AIR LOUVER
FRESH AIR LOUVER
TURNING VANES
UNDER FLOOR DUCT
ROUND DUCT - DROP
ROUND DUCT - RISE
NEGATIVE PRESSURE DUCT - DROP
TOP FIGURES INDICATE
NECK SIZE. BOTTOM
FIGURE INDICATES CFM.
12/8
12Ø
UP
DN
12/12 12Ø
1.5D
D
12Ø 12/12
FLANGE
PRESSURE GAUGE WITH PIGTAIL
PRESSURE GAUGE WITH SHUT-OFF COCK
ANCHOR
DEMOLITION
ALIGNMENT GUIDE
FLEXIBLE EXPANSION JOINT
SOLENOID VALVE
NATURAL GAS
S
G
DN
T
UNION
FLOW METER ORIFICE
FLOW SWITCH
TEMPERATURE AND PRESSURE TEST PORT
PRESSURE SWITCH
PRESSURE REDUCING, SELF CONTAINED VALVE
PRESSURE REDUCING, EXTERNAL PRESSURE VALVE
BALL VALVE (PIPE SIZES 2" AND SMALLER) BUTTERFLY
VALVE (PIPE SIZES 2-1/2" AND LARGER)
CHECK VALVE
MOTOR OPERATED BUTTERFLY VALVE
GAS COCK
RELIEF VALVE
GATE VALVE
ATC VALVE - 2 WAY
ATC VALVE - 3 WAY
GLOBE VALVE
CALIBRATED BALANCING VALVE
WITH GPM INDICATED
SHUT-OFF COCK FOR USE WITH PRESSURE GAUGE
FLOW METER
90° ELBOW
45° ELBOW
THERMOMETER - TEMP RANGE AS INDICATED
NIGHT THERMOSTAT
STEAM TRAP, F&T=FLOAT & THERMOSTATIC
B=BUCKET, T=THERMOSTATIC
ARROW INDICATES DIRECTION OF FLOW IN PIPE
LEADER INDICATES DOWNWARD SLOPE
RISER - DOWN (ELBOW)
RISER - UP (ELBOW)
BRANCH - SIDE CONNECTION
CLEAN-OUT
FLOOR CLEAN-OUT OR
CLEAN-OUT TO GRADE
VENT THRU ROOF
PLUMBING FIXTURES
POINT OF CONNECTION
SECTION TAG - TOP FIGURE IS SECTION NO.
BOTTOM FIGURE IS SHEET NO.
DETAIL TAG - TOP FIGURE IS DETAIL NO.
BOTTOM FIGURE IS SHEET NO.
EQUIPMENT IDENTIFICATION
KEYED NOTE IDENTIFICATION
FIXTURE FROM LEVEL ABOVE
P-1
EF
A M-101
A
M101
RPBP
GPM0.0
O-1
00° F
S
T
BRANCH - BOTTOM CONNECTION
BRANCH - TOP CONNECTION
MECHANICAL
FLOOR SINK
FLOOR DRAIN
AIR VENT-MANUAL
AIR VENT-AUTOA
REDUCER
HOSE BIBB
PIPE CAP
SWITCH
THERMOSTAT
S SENSOR
ROOF DRAIN
DOWNSPOUT NOZZLE
INLINE PUMP
INLINE PUMP
WATER HAMMER ARRESTOR
CONCENTRIC REDUCER
ECCENTRIC REDUCER
CEILING RETURN AIR GRILLE
W/ SOUND BOOT
BDD
BACK DRAFT DAMPER
POSITIVE PRESSURE DUCT - RISE
POSITIVE PRESSURE DUCT - DROP
NEGATIVE PRESSURE DUCT - RISE
SD
1-WAY BLOW PATTERN
2-WAY BLOW PATTERN
2-WAY BLOW PATTERN
3-WAY BLOW PATTERN
4-WAY BLOW PATTERN
DUCT SMOKE DETECTOR
UNIT HEATER
FCO
COTG
GATE VALVE - NON RISING STEM
ANGLE VALVE
BALANCING COCK
VALVE IN RISE
FILL PORT
DRAIN PAN AND P-TRAP
PLUMBING PLUMBING CONT. LINETYPES
SYMBOLS
RISE OR DROP
REDUCED PRESSURE BACKFLOW
PREVENTOR W/ DRAIN PAN LUBRICATED PLUG COCK
THERMOSTATIC MIXING VALVE
EXISTING PIPING TO BE REMOVED
AutoCAD SHX Text Description
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Layers Used
AutoCAD SHX Text Drawing Description
AutoCAD SHX Text File No.
AutoCAD SHX Text Checked:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Drawn:
AutoCAD SHX Text Date:
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
GR
AutoCAD SHX Text March 18, 2026
AutoCAD SHX Text 260048
AutoCAD SHX Text Seal
AutoCAD SHX Text 3-18-2026
AutoCAD SHX Text
JN
Fax: 801 466 6022
Suite 210 2180 South 1300 East
Phone: 801 466 3996
H O
LL
AD
AY
L
IO
N
S R
EC
R
EA
TI
O N
C
EN
TE
R
R O
O F
TO
P
U N
IT
R
EP
LA
C
EM
EN
T
E M
U R
R
AY
H O
LL
AD
AY
R
D , M
IL
LC
R
EE
K, U
T
181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com
Project #: 260048
L
IC
EN
SE
D P
ROFE SS I ONAL ENG
IN
E
ER
No. 4775391-2202
STAT E O F U TAH
SPENCER W.
HOWELL
MECHANICAL
GENERAL
NOTES
M0.2
1. MECHANICAL CONTRACTOR SHALL ENSURE THAT ALL
EQUIPMENT IS PROVIDED AND INSTALLED WITH CLEARANCES
PER MANUFACTURERS RECOMMENDATIONS. THE CONTRACTOR
SHALL MAINTAIN PROPER SERVICE SPACE FOR COIL PULLS, BAS
DEVICES, MAINTENANCE ACCESS, ETC.
2. THE CONTRACTOR SHALL INFORM THE DESIGNER OF ANY
PROPOSED DEVIATIONS FROM THE CONTRACT DOCUMENTS.
1. ALL WORK DONE SHALL BE PERFORMED WITH WATER
CONTROL IN MIND. CONTAINMENT OF WATER IS
NECESSARY TO PREVENT WATER FROM DAMAGING
AREAS ON FLOORS BELOW.
2. PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE. FIELD
VERIFY EXACT PIPE ROUTING AND COORDINATE WITH ALL
OTHER TRADES.
3. NO PIPING TO RUN OVER ELECTRICAL PANELS, VFD'S OR
MCC'S. PROTECT EQUIPMENT WITH A 42" DEEP ZONE IN
FRONT OF PANELS, VFD'S, AND MCC'S.
4. EXISTING PIPING AND ROUTING SHOWN, INCLUDING ALL
BELOW FLOOR DECK PIPING, IS APPROXIMATE. IT IS UP
TO THE CONTRACTOR TO FIELD VERIFY THE EXACT
LOCATION AND SIZE OF ALL PIPING.
5. INSTALL A 24" X 24" ACCESS DOOR BELOW ALL ISOLATION
VALVES & CIRCUIT SETTERS WHERE MOUNTED ABOVE
HARD CEILINGS.
6. MOUNT ALL ISOLATION VALVES, CONTROL VALVES,
CIRCUIT SETTERS, ETC. NEAR CEILING HEIGHT FOR
ACCESSIBILITY.
7. INSTALL ALL EQUIPMENT WITH SUFFICIENT CLEARANCE
FOR MAINTENANCE PER MANUFACTURERS
RECOMMENDATION.
8. ALL PIPE AND DUCT SIZES SHALL REMAIN THE SAME SIZE
SHOWN, IN THE DIRECTION OF FLOW, UNTIL SHOWN
OTHERWISE.
9. EXISTING PIPING AND VALVES, ETC. SHOWN LIGHT.
10. NEW PIPING AND VALVES, ETC. SHOWN DARK.
1. EXISTING DRAWINGS WERE BASED ON INFORMATION
FROM RECORD DRAWINGS PROVIDED BY THE OWNER.
THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS, INCLUDING BUT NOT LIMITED TO,
DUCTWORK ROUTING, PIPE ROUTING, EQUIPMENT
LOCATIONS, STRUCTURE AND ALL OTHER TRADES. THE
CONTRACTOR IS RESPONSIBLE TO MAKE MODIFICATIONS
AS REQUIRED TO PROVIDE A COMPLETE, WORKING
SYSTEM AT NO ADDITIONAL COST.
2. CONTRACTOR SHALL ENSURE THAT PLUMBING PIPING,
MECHANICAL PIPING, FIRE PROTECTION PIPING,
DUCTWORK, GRILLES, REGISTERS AND DIFFUSERS
REMOVED WILL NOT AFFECT SYSTEMS THAT REMAIN.
3. CONTRACTOR SHALL COORDINATE ALL WORK WITH THE
OWNER. CAREFUL PLANNING AND SCHEDULING OF WORK
SHALL BE DONE IN ADVANCE TO ENSURE THAT AREAS
ADJACENT TO THE REMODEL AREA REMAIN
OPERATIONAL.
4. ALL WORK SHALL BE DONE WITH WATER CONTROL IN
MIND. CONTAINMENT OF WATER IS NECESSARY TO
PREVENT WATER FROM DAMAGING OTHER AREAS OF THE
BUILDING.
5. THE LOCATION AND ROUTING OF ALL EXISTING
DUCTWORK, EQUIPMENT AND PIPING IS ONLY
APPROXIMATE AND IS SCHEMATIC IN NATURE. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE
EXACT LOCATION OF ALL EXISTING SYSTEMS AND
CONDITIONS.
6. EXISTING DUCTWORK, PIPING AND EQUIPMENT SHOWN
LIGHT.
7. NEW DUCTWORK, PIPING AND EQUIPMENT SHOWN DARK.
8. NEW DUCTWORK, PIPING AND EQUIPMENT SHALL BE
COORTINATED WITH STRUCTURE, LIGHTS, REFLECTED
CEILING PLANS, CABLE TRAY, ELECTRICAL CONDUIT,
PLUMBING, MECHANICAL, ALL OTHER TRADES AND ALL
OTHER EXISTING CONDITIONS.
9. THE CONTRACTOR SHALL INFORM THE DESIGNER OF ANY
PROPOSED DEVIATIONS FROM THE CONTRACT
DOCUMENTS.
10. NOT ALL INFORMATION IS SHOWN ON THE HVAC
DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR COORDINATING NFORMATION ON ALL OTHER
CONSTRUCTION DOCUMENTS INCLUDING
ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND
ELECTRICAL DRAWINGS. THE CONTRACTOR WILL BE
FAMILIAR WITH THE DRAWINGS, SPECIFICATIONS, AND
ADDENDUMS.
11. THE WORKING DRAWINGS ARE DIAGRAMMATIC (DRAWING
ARE NOT TO BE SCALED). BECAUSE OF THE SMALL SCALE
OF THE DRAWINGS, THEY DO NOT SHOW EVERY OFFSET,
BEND OR ELBOW NECESSARY FOR THE COMPLETE
INSTALLATION IN THE SPACE PROVIDED. ALL LOCATIONS
FOR HVAC EQUIPMENT SHALL BE CHECKED AND
COORDINATED WITH THE ARCHITECTURAL, MECHANICAL,
AND ELECTRICAL DRAWINGS.
12. THE DRAWINGS AND SPECIFICATION HAVE BEEN
PREPARED TO SUPPLEMENT EACH OTHER AND THEY
SHALL BE INTERPRETED AS AN INTEGRAL UNIT WITH THE
ITEMS SHOWN ON ONE AND NOT THE OTHER BEING
FURNISHED AND INSTALLED AS THOUGH SHOWN AND
CALLED OUT IN BOTH.
13. ANY PART OF THIS INSTALLATION THAT FAILS, IS UNFIT,
OR BECOMES DAMAGED DURING CONSTRUCTION SHALL
BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO
ADDITIONAL COST TO THE OWNER.
14. COORDINATE THE RETURN OF ALL MECHANICAL
EQUIPMENT REMOVED DURING DEMOLITION, WITH THE
OWNER'S REPRESENTATIVE.
15. ALL EQUIPMENT SHALL PROVIDE THE SCHEDULED
PERFORMANCE AT THE SITE ALTITUDE.
16. THE CONTRACTOR IS RESPONSIBLE FOR ALL EQUIPMENT
(INCLUDED IN THIS BID) CHECK-IN, SAFEKEEEPING, AND
DAMAGE.
17. FOR TIE-IN'S INTO EXISTING BUILDING SYSTEM THIS
CONTRACTOR SHALL BE REQUIRED TO DRAIN DOWN
WATER FROM SYSTEM AND BLEEDING AIR FROM
SYSTEMS WHERE REQUIRED.
AutoCAD SHX Text Description
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Layers Used
AutoCAD SHX Text Drawing Description
AutoCAD SHX Text File No.
AutoCAD SHX Text Checked:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Drawn:
AutoCAD SHX Text Date:
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
GR
AutoCAD SHX Text March 18, 2026
AutoCAD SHX Text 260048
AutoCAD SHX Text Seal
AutoCAD SHX Text 3-18-2026
AutoCAD SHX Text
JN
AutoCAD SHX Text
MECHANICAL GENERAL NOTES
AutoCAD SHX Text
PLUMBING GENERAL NOTES
GENERAL NOTES
RECEPTION
OFFICE
STORAGE
ELECTRICAL
CORRIDOR
CORRIDOR
GYMNASIUM
MULTI-PURPOSE
ELEVATOR
EQUIPMENT
MEN'S
RESTROOM
WOMEN'S
RESTROOM
OFFICE
STORAGE
STORAGE
OFFICE
OFFICE
CONFERENCE
CORRIDOR
CORRIDOR
CHILD CARE
RESTROOM
LOBBY
STORAGE
CLASSROOM
107 OFFICE
ELECTRICAL
STORAGE
OFFICE
ENTRY
VESTIBULE
DCBA
12/12
20/12
14"Ø
"Ø
/14
/16
18/12 8"Ø
22/12
8/6
8/6 UP
8/6
8/6 UP
10"Ø
10"Ø
6"Ø 8"Ø
10"Ø
10"Ø
10"Ø
16/14
6"Ø
10"Ø
10"Ø
8"Ø 8"Ø
8"Ø
8"Ø
8"Ø
10"Ø
8"Ø
8"Ø 12/12
12/10
36/17
SA UP
14/41
38/12 RA
32/14 SA
8"Ø
S
S
S S
T
16/14
12Ø 500 (14)
(E)UH
/12
10Ø 320 (5)
12Ø (2)
10Ø (5)
28Ø O.D.
28Ø O.D.
16/12
(E)VF
T
T
T
T
T
T
(E)ECH
/12
/12
Ø
/12
/12
38/14
/1436/120 SWR-2
24/108 SWR-2
24/12 16/12
10/10 200 (2)
22/12 10/12
8Ø
22/12
8/8
24/12 8/8 150(2)
8/8
10/12
10Ø 250(4)
8Ø
600600600
/12
24/16
200200200
24/108 SWR-2
16/16
16/16
L
16/12
16/16
SWR-1
16/16 SWR-1
1500 (2)
24/12
24/12
/14
14/14
(E)VF
T
T
S
12/12
10Ø 300 (2)
TT
T
14/10
12Ø
/12
16/12
10/10
8Ø 150 8Ø
8Ø
8/8 150(2)
12/12 625(2)
18/12
10/10
14/12 16/12
8/8
8/8
UP
12/12 625 (2)
8/8 150(2)
10Ø
FD
FD
14/10 SA
UP TO RTU-7
UP TO RTU-1 UP TO RTU-2
UP TO RTU-4
UP TO RTU-3
22/12 SA UP
22/12 RA UP
RTU-9 ON ROOF
1 1
A1.4
A1.2
A1.5
A1.1 A1.1
A1.5
A1.3
BID ALTERNATE 1
(E) RTU-7 (E) RTU-8
(E) RTU-9
(E) RTU-2
(E)RTU-6
(E)RTU-5
(E) RTU-3
10"Ø mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210 2180 South 1300 East
Phone: 801 466 3996
H O
LL
AD
AY
L
IO
N
S R
EC
R
EA
TI
O N
C
EN
TE
R
R O
O F
TO
P
U N
IT
R
EP
LA
C
EM
EN
T
E M
U R
R
AY
H O
LL
AD
AY
R
D , M
IL
LC
R
EE
K, U
T
181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com
Project #: 260048
L
IC
EN
SE
D P
ROFESS I ONAL ENG
IN
E
ER
No. 4775391-2202
S TA T E O F UTAH
SPENCER W.
HOWELL
ALTERNATE NOTES
KEYED NOTES#
1. DEMOLISH EXISTING CONTROLS LOCATED AT THIS
APPROXIMATE LOCATION.
2. DEMOLISH EXISTING SENSOR LOCATED BEHIND RETURN
GRILLE.
DEMOLISH EXISTING SUPPLY DUCT, BRANCH RUNOUT, FLEX AND
SUPPLY DIFFUSER. TYPICAL.
DEMOLISH EXISTING RETURN DUCTING FROM EXISTING RETURN
PLENUM ABOVE CEILING TO EXISTING ROOF TOP UNIT. COORDINATE
WITH SITE CONDITIONS.
EXISTING RETURN GRILLE AND ASSOCIATED PLENUM TO ABOVE
CEILING TO REMAIN INTACT FOR FUTURE CONNECTION.
DEMOLISH EXISTING CONTROLS AT THIS APPROXIMATE LOCATION.
DEMOLISH ALL EXISTING SUPPLY AND RETURN DUCTING TO ROOF
TOP UNIT.
A1.1
A1.2
A1.3
A1.4
A1.5
M1.1D SCALE: 1/8" = 1'-0"
0' 8' 16'
1 MECHANICAL FLOOR DEMOLITION PLAN
MECHANICAL
DEMOLTION FLOOR
PLAN
M1.1D
AutoCAD SHX Text Description
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Layers Used
AutoCAD SHX Text Drawing Description
AutoCAD SHX Text File No.
AutoCAD SHX Text Checked:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Drawn:
AutoCAD SHX Text Date:
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
GR
AutoCAD SHX Text March 18, 2026
AutoCAD SHX Text 260048
AutoCAD SHX Text Seal
AutoCAD SHX Text 3-18-2026
AutoCAD SHX Text
JN
DCBA
(E)RTU
(E)RTU
(E)RTU
(E)RTU
(E)RTU
(E)RTU
(E)RTU
(E)RTU
(E)RTU
1 1
A1.1 A1.1
A1.2A1.2
(E ) 2
P
SI
G
(E) 2 PSI G
(E) 2 PSI G
(E ) 2
P
SI
G
(E ) 2
P
SI
G
(E) 2 PSI G
(E ) 2
P
SI
G
(E)1"
(E)3/4"(E)3/4"
(E)1 1/4"
(E)3/4"
(E)3/4"
(E)1 1/2"
(E)1"
(E)3/4"
(E)3/4"
(E) 2 PSI G
(E) 3/4"
(E) 3/4"
(E) 1"
(E) 3/4"
(E) 3/4"
(E)RTU
BID ALTERNATE 1
(E)RTU
(E)RTU
(E) VTR
(E) VTR
(E) VTR
(E) HOOD
(E) VTR
(E) 2 PSI G
(E) VTR
(E)VF
(E)EF
(E)EF
(E)EF
(E)EF
(E)RTU
mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210 2180 South 1300 East
Phone: 801 466 3996
H O
LL
AD
AY
L
IO
N
S R
EC
R
EA
TI
O N
C
EN
TE
R
R O
O F
TO
P
U N
IT
R
EP
LA
C
EM
EN
T
E M
U R
R
AY
H O
LL
AD
AY
R
D , M
IL
LC
R
EE
K, U
T
181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com
Project #: 260048
L
IC
EN
SE
D P
ROFESS I ONAL ENG
IN
E
ER
No. 4775391-2202
S TA T E O F UTAH
SPENCER W.
HOWELL
ALTERNATE 1 NOTES
KEYED NOTES#
ROOF
MECHANICAL
DEMOLITION PLAN
M1.2D
M1.2D SCALE: 1/8" = 1'-0"
0' 8' 16'
1 MECHANICAL FLOOR PLAN
(E)PRESSURE TEST TEE
WITH 1/2" BRANCH
WITH 1/2X1/4 BUSHING
PLUG, (TYP. 2)
TO EQUIPMENT
(E)DIRT LEG WITH CAP
(E)GAS SUPPLY
(E)SHUT-OFF VALVE (E)1/4" PIPE
(E)FLEX CONNECTOR
(E)PRESSURE
REGULATOR
1. DEMOLISH EXISTING ROOFTOP UNIT AND CURB ADAPTOR.
ASSOCIATED ROOF CURB TO REMAIN INTACT. TYPICAL.
2. DEMOLISH EXISTING ROOF TOP UNIT, CURB ADAPTER AND
CURB.
3. DEMOLISH REGULATOR AND GAS PIPING BACK TO SHUTOFF
VALVE. REFERENCE ROOF TOP GAS PIPING DEMOLITION
DETAIL.
DEMOLISH EXISTING RTU, CURB ADAPTER AND CURB.
DEMOLISH REGULATOR AND GAS PIPING BACK TO SHUTOFF VALVE.
REFERENCE ROOF TOP GAS PIPING DEMOLITION DETAIL.
A1.1
A1.2
AutoCAD SHX Text Description
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Layers Used
AutoCAD SHX Text Drawing Description
AutoCAD SHX Text File No.
AutoCAD SHX Text Checked:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Drawn:
AutoCAD SHX Text Date:
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
GR
AutoCAD SHX Text March 18, 2026
AutoCAD SHX Text 260048
AutoCAD SHX Text Seal
AutoCAD SHX Text 3-18-2026
AutoCAD SHX Text
JN
AutoCAD SHX Text N
AutoCAD SHX Text M1.2D
AutoCAD SHX Text
AutoCAD SHX Text
ROOTOP GAS PIPING DEMOLITION DETAIL
NO SCALE
DCBA
12/12
20/12
14"Ø
"Ø
/14
/16
18/12 8"Ø
22/12
8/6
8/6 UP
8/6
8/6 UP
10"Ø
10"Ø
6"Ø 8"Ø
10"Ø
10"Ø
10"Ø
16/14
6"Ø
10"Ø
10"Ø
8"Ø 8"Ø
8"Ø
8"Ø
8"Ø
10"Ø
8"Ø
8"Ø 12/12
12/10
36/17
SA UP
14/41
38/12 RA
32/14 SA
8"Ø
S
S
S S
16/14
(E)UH
10Ø 320 (5)
12Ø (2)
10Ø (5)
28Ø O.D.
28Ø O.D.
16/12
(E)VF
T
T
T
(E)ECH
24/108 SWR-2
24/12 16/12
10/10 200 (2)
22/12 10/12
8Ø
22/12
8/8
24/12 8/8 150(2)
8/8
10/12
10Ø 250(4)
8Ø
600600600
/12
24/16
200200200
24/108 SWR-2
16/16
16/16
L
16/16
SWR-1
16/16 SWR-1
1500 (2)
24/12
24/12
/14
14/14
(E)VF
T
T
12/12
10Ø 300 (2)
T
14/10
12Ø
/12
16/12
10/10
8Ø 150 8Ø
8Ø
8/8 150(2)
12/12 625(2)
18/12
10/10
14/12 16/12
8/8
8/8
UP
12/12 625 (2)
8/8 150(2)
10Ø
FD
FD
14/10 SA
UP TO RTU-7
22/12 SA UP
22/12 RA UP
RTU-9 ON ROOF
(E) RTU-3
10"Ø
15Ø 625 (8)15Ø
625(8)
14/16
/16
/16
/16
/16
46/16
SWR-2
10,000
36/18
36/18
36/18 SA UP
36/18 RA UPA1.2
RA UP
SA UP
A1.2
A1.2
A1.2
A1.3
A1.1 A1.1
BID ALTERNATE 1
T
TT RTU-8.1RTU-7.1
RTU-5.1
RTU-6.1
T
T
T
RTU-1.1
RTU-2.1
RTU-3.1
RTU-4.1
S
RTU-2.2
RTU-9.1
/16
EXISTING
ELECTRONICS
HU
(E)2" DCW 3/4"
D
1"
1"
CP
D
FLOOR WALL
D
SEE PLAN
FOR SIZE
DC
W
D
HUMIDIFIER
CONDENSATE PUMP
mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210 2180 South 1300 East
Phone: 801 466 3996
H O
LL
AD
AY
L
IO
N
S R
EC
R
EA
TI
O N
C
EN
TE
R
R O
O F
TO
P
U N
IT
R
EP
LA
C
EM
EN
T
E M
U R
R
AY
H O
LL
AD
AY
R
D , M
IL
LC
R
EE
K, U
T
181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com
Project #: 260048
L
IC
EN
SE
D P
ROFESS I ONAL ENG
IN
E
ER
No. 4775391-2202
S TAT E O F U TAH
SPENCER W.
HOWELL
BID ALTERNATE 1#
NEW RETURN DUCTING TO CONNECT TO EXISTING RETURN PLENUM
ABOVE CEILING. CONNECT TO PLENUM AS REQUIRED.
PROVIDE TRANSITION AS REQUIRED TO CONNECT TO ROOF TOP
UNIT PROVIDED ON SITE.
PROVIDE NEW CONTROLS AT THIS APPROXIMATE LOCATION AT THE
SAME LOCATION AS EXISTING.
MECHANICAL
FLOOR PLAN
M1.1
M1.1 SCALE: 1/8" = 1'-0"
0' 8' 16'
1 MECHANICAL FLOOR PLAN
A1.1
A1.2
A1.3
# KEYED NOTES
1. PROVIDE NEW CONTROLS AT THIS APPROXIMATE LOCATION AT
THE SAME LOCATION AS EXISTING.
2. PROVIDE NEW SENSOR BEHIND RETURN GRILLE AT THIS
APPROXIMATE LOCATION.
3. ROUTE CONDENSATE DRAIN DOWN A LONG WALL TO FLOOR
SINK. TERMINATE WITH AIR GAP.
4. PROVIDE ISOLATION VALVE IN VERTICAL DROP TO HUMIDIFIER.
5. ROUTE DOMESTIC COLD WATER TO AN EXISTING DOMESTIC
COLD WATER 3/4" OR LARGER. COORDINATE DOMESTIC COLD
WATER ROUTING WITH SITE CONDITIONS.
6. ROUTE CONDENSATE DRAIN AS HIGH AS POSSIBLE AND
COORDINATE ROUTING WITH SITE CONDITIONS.
7. DO NOT ROUTE PIPING OVER ELECTRONICS.
AutoCAD SHX Text Description
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Layers Used
AutoCAD SHX Text Drawing Description
AutoCAD SHX Text File No.
AutoCAD SHX Text Checked:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Drawn:
AutoCAD SHX Text Date:
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
GR
AutoCAD SHX Text March 18, 2026
AutoCAD SHX Text 260048
AutoCAD SHX Text Seal
AutoCAD SHX Text 3-18-2026
AutoCAD SHX Text
JN
AutoCAD SHX Text N
AutoCAD SHX Text M1.1
AutoCAD SHX Text
AutoCAD SHX Text
HUMIDIFIER PIPING DETAIL
NO SCALE
DCBA
(E ) 2
P
SI
G
(E) 2 PSI G
(E) 2 PSI G
(E ) 2
P
SI
G
(E ) 2
P
SI
G
(E) 2 PSI G
(E ) 2
P
SI
G
(E)1"
(E)3/4"(E)3/4"
(E)1 1/4"
(E)3/4"
(E)3/4"
(E)1 1/2"
(E)1"
(E)3/4"
(E)3/4"
(E) 2 PSI G
(E) 3/4"
(E) 3/4"
(E) 1"
(E) 3/4"
(E) 3/4"
(E)RTU
(E)RTU
(E) VTR
(E) VTR
(E) VTR
(E) HOOD
(E) VTR
(E) 2 PSI G
(E) VTR
(E)VF
(E)EF
(E)EF
(E)EF
(E)EF
(E)RTU
RTU
6.1
RTU
5.1
RTU
9.1
RTU
8.1
RTU
7.1
RTU
2.1
RTU
4.1
RTU
1.1
RTU
3.1
A1.3
A1.1A1.1
A1.2A1.2
BID ALTERNATE 1
6 4
RTU
2.2 mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210 2180 South 1300 East
Phone: 801 466 3996
H O
LL
AD
AY
L
IO
N
S R
EC
R
EA
TI
O N
C
EN
TE
R
R O
O F
TO
P
U N
IT
R
EP
LA
C
EM
EN
T
E M
U R
R
AY
H O
LL
AD
AY
R
D , M
IL
LC
R
EE
K, U
T
181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com
Project #: 260048
L
IC
EN
SE
D P
ROFE SS I ONAL ENG
IN
E
ER
No. 4775391-2202
S TAT E O F U TAH
SPENCER W.
HOWELL
BID ALTERNATE 1
KEYED NOTES#
ROOF
MECHANICAL
PLAN
M1.2
M1.2 SCALE: 1/8" = 1'-0"
0' 8' 16'
1 MECHANICAL FLOOR PLAN
M1.2
2 GAS CONNECTION DETAIL
NO SCALE
PRESSURE TEST TEE
WITH 1/2" BRANCH
WITH 1/2X1/4 BUSHING
1/4" PIPE PLUG,
(TYP. 2)
FLEX CONNECTOR
TO EQUIPMENT
PRESSURE REGULATOR
(E)DIRT LEG WITH CAP
(E)ROOF
(E)GAS SUPPLY
(E)SHUT-OFF VALVE
(E)ROOF MEMBRANE
1. PROVIDE NEW GAS PIPING AND PIPING SPECIALTIES TO NEW
ROOF TOP UNIT. REFERENCE GAS CONNECTION DETAIL FOR
ADDITIONAL INFORMATION. TYPICAL.
2. PROVIDE GAS PIPING, SHUT-OFF VALVE, REGULATOR AND ANY
REQUIRED SPECIALTIES TO CONNECT ROOFTOP UNIT.
3. NEW AND EXISTING GAS PIPING TO BE PAINTED "YELLOW".
TYPICAL.
4. MIRO 3-R-2 PIPE SUPPORT NOT TO EXCEED 7'-0" ON CENTER.
EACH PIPE STAND IS TO BE INSTALLED PER MANUFACTURERS
RECOMMENDATIONS. GAS PIPING NOT TO BE SUPPORTED BY
ROOF TOP UNIT. PROVIDE SUPPORTS AS REQUIRED TO KEEP
GAS PIPING FROM BEING SUPPORTED BY ROOFTOP UNIT.
TYPICAL.
5. PROVIDE RTU WITH NEW CURB. REFERENCE ROOF TOP UNIT
SCHEDULE FOR CURB REQUIREMENTS.
6. NEW ROOF TOP UNIT WITH CURB ADAPTORS AS REQUIRED TO
MAKE SUPPLY AND RETURN AIR CONNECTIONS. TYPICAL.
PROVIDE NEW CURB UNDER ROOF TOP UNIT. REFERENCE
ROOF TOP UNIT SCHEDULE FOR CURB REQUIREMENTS.
PROVIDE NEW GAS PIPING AND PIPING SPECIALTIES TO NEW
ROOF TOP UNIT AS REQUIRED. REFERENCE GAS CONNECTION
DETAIL FOR ADDITIONAL INFORMATION. TYPICAL.
MIRO 3-R-2 PIPE SUPPORT NOT TO EXCEED 7'-0" ON CENTER.
EACH PIPE STAND IS TO BE INSTALLED PER MANUFACTURERS
RECOMMENDATIONS. TYPICAL.
A1.1
A1.2
A1.3
AutoCAD SHX Text
TYP.
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text Description
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Layers Used
AutoCAD SHX Text Drawing Description
AutoCAD SHX Text File No.
AutoCAD SHX Text Checked:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Drawn:
AutoCAD SHX Text Date:
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
GR
AutoCAD SHX Text March 18, 2026
AutoCAD SHX Text 260048
AutoCAD SHX Text Seal
AutoCAD SHX Text 3-18-2026
AutoCAD SHX Text
JN
GRILLE LENGTH
RETURN AIR GRILLE
12" MINIMUM THROAT
SHEET METAL SOUND
BOOT W/ 1" ACOUSTIC
DUCT LINER
SUPPORT SOUND
BOOT FROM
STRUCTURE
1/2 GRILLE
WIDTH (6" MIN.) ATTACH BOOT TO
GRILLE W/ SHEET
METAL SCREWS (2)
EA. SIDE
4" MINIMUM
THROAT
ROOF TOP UNIT
ALUMINUM WEATHER SEAL
ALL DIRECTIONAL
NEOPRENE BUSHING
CONTINUOUS
WOOD NAILER
CANT STRIP
ROOFING
SPRING ISOLATION CURB WITH
INTEGRAL SEISMIC RESTRAINT
NEOPRENE
ACOUSTICAL SEAT
CROSS BRACE
SUB FRAME TO COMPENSATE
FOR INSULATION THICKNESS AND
ROOF SLOPE.
W
W
6"
SHEET METAL RETURN AIR
BOOT LINE WITH 1"
ELEVATION VIEW
WALL
ACOUSTICAL INSULATION
(12" MIN.)
2W
AIR FLOW
L
NOTE:
DAMPERS SHOULD NOT
BE INSTALLED CLOSER
THAN TWO DUCT WIDTHS
TO ELBOWS OR
INTERSECTIONS.
REMOTE
CEILING
OPERATOR
WHERE
DAMPER IS
INACCESIBLE
NOTE
L=1/4 W (4" MIN.)
VOLUME DAMPER
PROVIDE
CONCEALED
CEILING DAMPER
REGULATORW
45°
NOTE:
RETURN SIMILAR BUT
WITHOUT DUCT
MAKE BEND RADIUS
1 1/2 x DUCT RADIUS
FLEX DUCT
SEE PLAN FOR SIZE
CEILING
TIGHTENING BAND
SUPPORT FLEX
DUCT AND
DIFFUSER FROM
STRUCTURE
ABOVE
SHEET METAL SUPPLY
DUCT. SEE PLANS FOR SIZE
NOTES:
100% OUTSIDE AIR FACTORY ECONOMIZER
HOOD WITH ADJUSTABLE MINIMUM
CONDENSATE DRAIN & TRAP,
SEE PLANS FOR CONTINUATION
ROOFING & STRUCTURE
ROOF DECK CONTINUES BELOW UNIT
PROVIDE (2) LAYERS OF 5/8" DRYWALL TO ENCAPSULATE
THE ENTIRE BOTTOM OF UNIT
PROVIDE RESILIENT CAULKING (TYPICAL)
CODE APPROVED SMOKE DETECTOR IN
RETURN DUCT (SYSTEMS SUPPLYING MORE
THAN 2,000 CFM) REFER TO ELECTRICAL.
RETURN AIR DUCT, SEE
FLOOR PLANS FOR SIZESSUPPLY & RETURN AIR
PLENUMS WITH SOUND INSULATION
SUPPLY AIR DUCT & SQUARE
TO ROUND LOW-LOSS FITTING,
SUPPLY & RETURN AIR DUCTS
WITH SOUND INSULATION,
TRANSITION DUCTS AS REQUIRED (TYP.)
14" HIGH FACTORY ROOF CURB WITH
CANT. STRIP, FLASHING AND
VIBRATION ISOLATION,
SEE NOTES BELOW
1. COORDINATE EXACT LOCATION AND FRAMING OF ROOF
OPENING WITH GENERAL CONTRACTOR.
2. VIBRATION ISOLATION - SHALL BE FACTORY FURNISHED
SPRING ISOLATOR.
SEE FLOOR PLANS FOR SIZES.
SEE FLOOR PLAN FOR SIZES
COUNTER-FLASHING
POSITION & SPRING RETURN DAMPER
(MIN.)
(MIN.)(MIN.)(MIN.)
DD
(MIN.)
30° ELBOW
2 PIECE
45° ELBOW
3 PIECE
60° ELBOW
4 PIECE
90° ELBOW
5 PIECE
D D
DDDDDD
11.25°
.25
° 10
10°
20°
11.
25°
.5°
22.
5°
.5°
.25
DUCT
TRUNK
DUCT
TRUNK
DUCT
TRUNK
TRUNK DUCT
AIR FLOW
AIR FLOW
AIR FLOW
AIR FLOW
BRANCH DUCT
BRANCH DUCT
BRANCH DUCT
BRANCH DUCT
90° CONICAL TEE
90° ELONGATED TEE
2-WAY 45° Y
45° Y TEE
DUCT
BEND TAB UNDER
NOTE:
USE SPECIFIED SPACING AND NOT LESS THAN ONE SUPPORT
PER BRANCH.
1 1/4" x 16 GAUGE
SHEET METAL STRAP,
TYPICAL
DOUBLE FOLD STRAP AND
SECURE TO TOP CHORD
OF TRUSSES.
#10 SHEET METAL SCREW
6" ON CENTER, TYP.
ROUND HETO
VOLUME DAMPER
RIGID DUCT, SEE PLANS.
AIR FLOW
ROUND DUCT
AT EACH BRANCH TAKE-OFF
6" OF PANEL POINT
LOCATE UNISTRUT WITHIN
UNISTRUT
45° mail@hhyassoc.com
Salt Lake City, UT 84106
Fax: 801 466 6022
Suite 210 2180 South 1300 East
Phone: 801 466 3996
H O
LL
AD
AY
L
IO
N
S R
EC
R
EA
TI
O N
C
EN
TE
R
R O
O F
TO
P
U N
IT
R
EP
LA
C
EM
EN
T
E M
U R
R
AY
H O
LL
AD
AY
R
D , M
IL
LC
R
EE
K, U
T
181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com
Project #: 260048
L
IC
EN
SE
D P
ROFE SS I ONAL ENG
IN
E
ER
No. 4775391-2202
S TAT E O F U TAH
SPENCER W.
HOWELL
MECHANICAL
DETAILS
M5.1
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
R.A. GRILLE WITH SOUND BOOT
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
ROOFTOP UNIT CURB DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
RETURN AIR SOUND BOOT DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
BRANCH DUCT TAKE-OFF & DAMPER DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
DIFFUSER CONNECTION DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
SD
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
ROOFTOP UNIT WITH NEW CURB DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
HIGH EFFICIENCY TAKE-OFF DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
SUPPORT DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
RECTANGULAR DUCT SUPPORT DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
ROUND DUCT ELBOW DETAILS
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text M5.1
AutoCAD SHX Text
AutoCAD SHX Text
ROUND DUCT BRANCH TAKE-OFF DETAILS
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text Description
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Layers Used
AutoCAD SHX Text Drawing Description
AutoCAD SHX Text File No.
AutoCAD SHX Text Checked:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Drawn:
AutoCAD SHX Text Date:
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
GR
AutoCAD SHX Text March 18, 2026
AutoCAD SHX Text 260048
AutoCAD SHX Text Seal
AutoCAD SHX Text 3-18-2026
Fax: 801 466 6022
Suite 210 2180 South 1300 East
Phone: 801 466 3996
H O
LL
AD
AY
L
IO
N
S R
EC
R
EA
TI
O N
C
EN
TE
R
R O
O F
TO
P
U N
IT
R
EP
LA
C
EM
EN
T
E M
U R
R
AY
H O
LL
AD
AY
R
D , M
IL
LC
R
EE
K, U
T
181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com
Project #: 260048
L
IC
EN
SE
D P
ROFE SS I ONAL ENG
IN
E
ER
No. 4775391-2202
S TAT E O F U TAH
SPENCER W.
HOWELL
MECHANICAL
SCHEDULES
M6.1
PACKAGED ROOFTOP UNIT SCHEDULE
VENTILATION AIR SUPPLY FAN HEATING SECTION COOLING SECTION ELECTRICAL PHYSICAL
EXTERNAL HEATING HEATING OA ENTERING/ TOTAL SENSABLE OA ENTERING LEAVING SUPPLY SUPPLY MANUFACTURER OCCUPIED AIRFLOW STATIC INPUT OUPUT TEMP. LEAVING COOLING COOLING TEMP. AIR TEMP. AIR TEMP. FAN FAN TOTAL SINGLE
BID AND AREA NOMINAL MINIMUM RATE PRESSURE LOAD LOAD DB AIR TEMP. LOAD LOAD DB/WB DB/WB DB/WB EER / IEER/ MOTOR MOTOR MCA MOCP POINT L / W / H WEIGHT ID ALTERNATE MODEL NUMBER LOCATION SERVED TONNAGE (CFM) (CFM) (IN. WATER) (BTU/H) (BTU/H) (°F) (°F) MEDIUM / MODULATION (BTU/H) (BTU/H) (°F) (°F) (°F) MEDIUM EER2 SEER SEER 2 QUANTITY (HP) CIRCUIT 1 CIRCUIT 1 VOLT/PH (IN) (LBS) NOTES
RTU-1.1 BASE BID YORK KJ150N24R4DAACD1A1 GYM ROOF GYM 12.5 1140 5000 0.8 196,800 159,100 0 52 / 86.7 NATURAL GAS / 2 STAGE 161,500 112,300 97 / 62 78 / 62 53.5 / 49.8 R454B 12 / - 15 / - - 1 5 36.6 45 460 / 3 120 / 59 / 51 1550 1-11,12,15,16 RTU-2.1 BASE BID YORK KJ150N24R4DAACD1A1 GYM ROOF GYM 12.5 1140 5000 0.8 196,800 159,100 0 52 / 86.7 NATURAL GAS / 2 STAGE 161,500 112,300 97 / 62 78 / 62 53.5 / 49.8 R454B 12 / - 15 / - - 1 5 36.6 45 460 / 3 120 / 59 / 51 1550 1-11,12,15,16 RTU-3.1 BASE BID YORK KJ150N24R4DAACD1A1 GYM ROOF GYM 12.5 1140 5000 0.8 196,800 159,100 0 52 / 86.7 NATURAL GAS / 2 STAGE 161,500 112,300 97 / 62 78 / 62 53.5 / 49.8 R454B 12 / - 15 / - - 1 5 36.6 45 460 / 3 120 / 59 / 51 1550 1-11,12,15,16 RTU-4.1 BASE BID YORK KJ150N24R4DAACD1A1 GYM ROOF GYM 12.5 1140 5000 0.8 196,800 159,100 0 52 / 86.7 NATURAL GAS / 2 STAGE 161,500 112,300 97 / 62 78 / 62 53.5 / 49.8 R454B 12 / - 15 / - - 1 5 36.6 45 460 / 3 120 / 59 / 51 1550 1-11,12,13,15,16 RTU-5.1 ALT 1 YORK KLG14E4C3AB5A113C1 ROOF MULTIPURPOSE 12.5 955 5000 0.75 182,200 145,700 0 60 / 91.6 NATURAL GAS / 2 STAGE 151,100 139,800 80 / 67 80 / 62 61.8 / 57.9 R454B 11 / - 14.7 / - - 1 5 33.3 40 460 / 3 87 / 62 / 55 1200 1-11,12,13,15,16 RTU-6.1 ALT 1 YORK KLG14E4C3AB5A113C1 ROOF MULTIPURPOSE 12.5 955 5000 0.75 182,200 145,700 0 60 / 91.6 NATURAL GAS / 2 STAGE 151,100 139,800 80 / 67 80 / 62 61.8 / 57.9 R454B 11 / - 14.7 / - - 1 5 33.3 40 460 / 3 87 / 62 / 55 1200 1-11,12,15,16 RTU-7.1 BASE BID YORK KE036H05B4CAACA1B1 ROOF OFFICES 3 250 900 0.5 41,000 32,800 0 53 / 87.8 NATURAL GAS / 2 STAGE 35,300 24,900 97 / 62 77 / 62 54.3 / 51.1 R454B - / 11.4 - / - 13.4 1 1.5 10.5 15 460 / 3 83 / 45 / 33 570 1-11,14,15,16 RTU-8.1 BASE BID YORK KE036H05B4CAACA1B1 ROOF CONFERENCE 3 250 1000 0.5 41,000 32,800 0 52 / 87.8 NATURAL GAS / 2 STAGE 32,900 23,300 97 / 62 78 / 62 52.6 / 49.5 R454B - / 11.4 - / - 13.4 1 1.5 10.5 15 460 / 3 83 / 45 / 33 570 1-11,14,15,16 RTU-9.1 BASE BID YORK KE048H12B4CAACA1B1 ROOF CHILD CARE 4 450 1600 0.5 102,500 82,000 0 50 / 105.9 NATURAL GAS / 2 STAGE 50,800 38,900 97 / 62 79 / 62 52.4 / 50 R454B - / 11.4 - / - 13.4 1 1.5 10.7 15 460 / 3 83 / 45 / 33 570 1-11,15,16 RTU-2.2 BASE BID YORK KJ150N24R4DAACD1A1 ROOF ADMIN 12.5 1140 5250 0.7 196,800 159,100 0 58 / 91.1 NATURAL GAS / 2 STAGE 162,800 116,000 97 / 62 80 / 62 55.9 / 51.5 R454B 12 / - 15 / - - 1 5 36.6 45 460 / 3 120 / 59 / 51 1550 1-11,12,15,16
1. CAPACITIES LISTED AT 4,500FT.
2. FAN MOTORS TO BE ECM & DIRECT DRIVE.
3. 2" MERV 8 FILTERS.
4. DRY BULB ECONOMIZER W/BAROMETRIC RELIEF AND POWER EXHAUST.
5. 2-STAGE COMPRESSOR.
6. UNIT TO BE PROVIDED WITH FACTORY INSTALLED BACNET/MSTP CARD.
7. REFRIGERANT DETECTION SYSTEM.
8. ALUMINIZED STEEL HEAT EXCHANGER.
9. PREWIRED VFD DRIVE.
10. DISCHARGE AIR, RETURN AIR AND OUTDOOR AIR TEMPREATURES SENSORS.
11. PROVIDE WITH HIGH-ALTITUDE GAS BURNER KIT.
12. PROVIDE WITH SMOKE DETECTOR IN RETURN.
13. PROVIDE WITH 14" TALL CURB.
14. PROVIDE WITH 38" TALL CURB.
15. PROVIDE WITH 115V / 1PH CONVIENCE OUTLET.
16. PROVIDE WITH PRE-WIRED FACTORY DISCONNECTS.
GRILLES, REGISTERS AND DIFFUSERS - ALTERNATE 1
ID MANUFACTURER MODEL DESCRIPTION
FACE STYLE: SQUARE PLAQUE DIFFUSER MOUNTING-FRAME: SURFACE OR LAY-IN, (C/W CEILING TYPE.)
FACE SIZE: 24" x 24" AS PATTERN: 360° RADIAL HORIZONTAL AIR PATTERN
CD-1 EH PRICE SPD REQUIRED TO FIT CEILING TILE SPACE AVAILABLE DAMPER: OPPOSED BLADE
APPLICATION: ENGINEERED VAV SYSTEMS MAX NC - 30
MATERIAL: STEEL DAMPER: NONE
FINISH: COORDINATE COLOR WITH ARCHITECT REMOVABLE FACE
1. ALL SUPPLY GRILLES ARE TO BE CD-1, UNLESS OTHERWISED NOTED.
2. ALL DUCT RUNOUT TO DIFFUSERS, GRILLES, REGISTERS ARE TO BE NECK SIZE, UNLESS OTHERWISED NOTED.
CONDENSATE PUMP SCHEDULE
WATER ELECTRICAL PHYSICAL
FEET LENGTH/ INLET / OUTLET
MANUFACTURER FLOW OF VOLT / WIDTH/ CONNECTION
AND RATE HEAD MOTOR PHASE / HEIGHT WEIGHT SIZE
ID MODEL NUMBER LOCATION TYPE (GPM) (FT) HP FLA HZ (IN) (LBS) (IN) NOTES
CP-1 NEPTRONICS PUMP404CV STORAGE ROOM AUTOMATIC DRAIN PUMP 12 17 1/3 5.2 115 / 1 / 60 13.75 / 13.75 / 11.625 13 1.5 / 1.5 1,2
1. DISCONNECT PROVIDED AND INSTALLED BY DIV. 26.
2. PROVIDE WITH 10 FEET ELECTRICAL CORD.
HUMIDIFIER SCHEDULE
STEAM ELECTRICAL PHYSICAL
LENGTH /
MANUFACTURER VOLT / DEPTH /
AND LOAD CAPACITY PHASE / HEIGHT WEIGHT
ID MODEL NUMBER LOCATION TYPE (LB/HR) (LB/HR) KW AMPS HZ (IN) (LBS) NOTES
HU-1 NEPTRONIC SKE4-N30-480-3 AEROBICS WALL MOUNTED 25.5 40 13.5 16.5 480 / 3 / 60 22.25 / 16.125 / 39.75 170 1-4
1. PROVIDE WITH DISPERSION MODEL: SF SDU4-2-480
2. PROVIDE WITH NF HRO20 - WALL MOUNTED MODULATING HUMIDITY CONTROLLER, NF SHR10 - WALL MOUNTED HUMIDITY SENSOR, NF SHS20 - WALL MOUNTED ON/OFF HIGH LIMIT HUMIDISTAT.
3. PROVIDE WITH SF PF10C.
4. DISCONNECT PROVIDED AND INSTALLED BY DIV. 26.
AutoCAD SHX Text Description
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Layers Used
AutoCAD SHX Text Drawing Description
AutoCAD SHX Text File No.
AutoCAD SHX Text Checked:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Drawn:
AutoCAD SHX Text Date:
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
GR
AutoCAD SHX Text March 18, 2026
AutoCAD SHX Text 260048
AutoCAD SHX Text Seal
AutoCAD SHX Text 3-18-2026
ELECTRICAL
LEGENDS & NOTES
EG001
(S) (S) SIMPLEX (D) DUPLEX (Q) QUADPLEX OR DOUBLE DUPLEX(D) (Q)
STANDARD CONVENIENCE OUTLET 18"
CONVENIENCE OUTLET, GFCI 18"
STANDARD CONVENIENCE OUTLET, HOSPITAL 18"18"
STANDARD CONVENIENCE OUTLET, SWITCHED 18"
STANDARD CONVENIENCE OUTLET, CUSTOM HEIGHT (6)
48"UNLESS
NOTED
CONVENIENCE OUTLET, GFCI, CUSTOM HEIGHT (6)
48"UNLESS
NOTED
CONVENIENCE OUTLET, ISOLATED GROUND 18"
CONVENIENCE OUTLET, FLOOR FLOOR
CONVENIENCE OUTLET, CEILING CEILING
VFD VARIABLE FREQUENCY DRIVE
J JUNCTION BOX AS NOTED (12)
J JUNCTION BOX, WALL AS NOTED (12)
J JUNCTION BOX, FLOOR FLOOR (12)
S
M MANUAL MOTOR CONTROLLER SWITCH WITHOUT
TERMINAL OVERLOAD PROTECTION
SWITCH WITH PILOT LIGHTS
P
MANUAL SWITCH WITH THERMAL OVERLOADS
TH
SINGLE POLE DOOR SWITCHS
X
PUSH BUTTON SWITCH, SINGLE AS NOTED
PUSH BUTTON SWITCH, DOUBLE AS NOTED
BUSH BUTTON SWITCH, TRIPLE AS NOTED
EMERGENCY POWER OFF (EPO) SWITCH
NON-FUSED DISCONNECT SWITCH (13) (14)
F FUSED DISCONNECT SWITCH (13) (14)
MAGNETIC STARTER (13) (14)
MAGNETIC STARTER WITH FUSED DISCONNECT (13) (14)
MAGNETIC STARTER WITH BREAKER DISCONNECT (13) (14)
R POWER RELAY (13) (14)
MOTOR OUTLET
MOTOR OUTLET, ROOF MOUNTED ROOF
T TRANSFORMER SEE PLANS
G EMERGENCY GENERATOR SEE PLANS
MAIN DISTRIBUTION POWER PANEL
PANEL BOARD, SURFACE 6'-6" TO TOP
PANEL BOARD, RECESSED 6'-6" TO TOP
SMOKE DETECTOR CEILING (9) (11)
SMOKE DETECTOR, LOW FREQUENCY, SOUNDER BASE CEILING (9)CEILING (9)
SMOKE DETECTOR, LOW FREQUENCY, SOUNDER BASE, WALL 7'-6" (9) (11)7'-6" (9) (11)
SMOKE DETECTOR, SOUNDER BASE, VISUAL IND. CEILING (9)
SMOKE DETECTOR, SOUNDER BASE, VISUAL IND., WALL 7'-6" (9) (11)
DUCT SMOKE DETECTOR SEE MECH. (9)
FSD FIRE/SMOKE DAMPER SEE MECH.FIRE/SMOKE DAMPER SEE MECH.
RM RELAY MODULE (9)
MONITOR MODULE (9)MM
CONTROL MODULE (9)CM
PRESSURE SWITCH (9)PS
TAMPER SWITCH (9)TS
FLOW SWITCH (9)FS
LOOP ISOLATION MODULE (9)IM
FIRE EXTINGUISHER MONITOR (9)XM
FIRE RISER SEE PLANS
FIRE ALARM PANEL, SURFACE (15)AS NOTED
FIRE ALARM PANEL, RECESSED (15)AS NOTED
XX
X MECHANICAL/PLUMBING EQUIPMENT CALLOUT
X-1 KITCHEN EQUIP. CALLOUT, OR AS NOTED BY ARCH.
X KITCHEN EQUIP. CALLOUT, OR AS NOTED BY ARCH.
X LUMINAIRE TYPE
X
XX.X DIAGRAM/DETAIL CALLOUT
CONDUIT RUN CONCEALED IN WALL OR CEILING
UG CONDUIT RUN CONCEALED IN FLOOR OR GROUND
SURFACE RACEWAY/WIREMOLD
LOW VOLTAGE CONDUIT RUN
DEMOLITION
EXISTING
HOME RUN TO PANEL
CONDUIT STUB
CONDUIT BREAK/CONTINUATION
CONDUIT STUB DOWN
CONDUIT STUB UP
FUSE
GROUND/GROUND ROD
CIRCUIT BREAKER
A AMPS
AFC AVAILABLE FAULT CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC AMPS INTERR. CAPACITY
AWG AMERICAN WIRE GAUGE
BC BARE COPPER
BFC BELOW FINISHED CEILING
BFG BELOW FINISHED GRADE
C CONDUIT
CND CONDUIT
CO CONDUIT ONLY
CT CURRENT TRANSDUCER
CU COPPER MATERIAL
DED DEDICATED
DFA DROP FROM ABOVE
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
EM EMER./EGRESS BATTERY
EMT ELEC. METALLIC TUBING
ENT ELEC. NON-METAL. TUBING
ER EXISTING TO BE RELOCATED
EX EXISTING TO REMAIN
FMC FLEXIBLE METAL CONDUIT
GC GENERAL CONTRACTOR
GEC GRND. ELEC. COND. AT SES
GFCI GRND. FLT. CURR. INTERR.
GFEP GRND. FLT. EQUIP. PROTECT.
GND GROUND
IMC INTER. METAL CONDUIT
IG ISOLATED GROUND
KCMIL 1000 CIRCULAR MILS (MCM)
LFMC LIQUID-TIGHT FLEX.
METAL. COND.
LFNC LIQUID-TIGHT FLEX.
NON-METAL. COND.
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPS
N1 NEMA 1
N3R NEMA 3R
N NEW
NL NIGHT LIGHT, BYPASS
LOCAL SWITCHING
PC PLUMBING CONTRACTOR
POC POINT OF CONNECTION
POS POINT OF SALE
R RELOCATED
RX RECEIVER
RM ROOF MOUNTED
RMC RIGID METALLIC CONDUIT
RNC RIGID NON-METALLIC COND.
SBJ SYSTEM BONDING JUMPER
SCA SHORT CIRCUIT AMPERES
TX TRANSMITTER
TC TEMP. CONTROL CONTR.
TR TAMPERPROOF
UG UNDERGROUND
UNO UNLESS NOTED OTHERWISE
VA VOLT/AMPS
VIF VERIFY IN FIELD
WP WEATHERPROOF/NEMA 3R
XP EXPLOSION PROOF
XR EXISTING TO BE REMOVED
ABBREVIATIONS
(1) SEE LUMINAIRE SCHEDULE FOR FIXTURE TYPES AND DETAILS.
(2) SEE LUMINAIRE SCHEDULE FOR MOUNTING REQUIREMENTS.
(3) WIRE LIGHT FIXTURE FROM ADJACENT J-BOX
(4) CONNECT NEAREST UN-SWITCHED HOT CONDUCTOR TO EMERGENCY BALLAST
(5…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .