The image is an Adobe PDF portfolio landing page with instructions to open the file in Acrobat X or Adobe Reader X. The page features the Adobe PDF logo, a red and white document icon, and a button to download Adobe Reader. The text recommends using the latest version of Adobe software for the best viewing experience of the PDF portfolio.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
ORF-1402219-A101
KEYNOTES
JMN
JMN 1402219
C O
N S
T R
U
IO
ENGINEERING SERVICES
TERMINAL
PROJECT ENGINEER MGR: CONSTRUCTION - CENTER B
DRAWING PRODUCED ON AEA RO MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
FOR 20-YEARS AND 130-MPH WIND LOADS.
SYSTEM SHALL BE DESIGNED, CERTIFIED AND WARRANTEED
APPROVED EQUAL. MATCH EXISTING COLOR AND STYLE. NEW
TERMINATION BARS, PITCH POCKETS, ETC., BY DURO-LAST OR
FURNISH AND INSTALL COPING METAL WALL CAPPING SYSTEM,
STEEL DECK ROOF ASSEMBLY NOTES
VA
GENERAL NOTES
05/24/2021
FACILITY ROOF REPLACEMENT
ROOF PLAN
TRACON
NORFOLK
o rf -1
-a
.d g n
TOWER LINK
ACCU-3
ACCU-4
H-1
EF-6
EF-4
EF-5
ENGINE GEN.
EXHAUST
H-2
H-4
CU-2
H-3
EF-2EF-3
CU-4
ACCU-2
ACCU-1
1 2 3 4 5
B
D
E
2.8
(TYP)
PIPE BOX
CU-3
BOX
PIPE EF-1
BASE
ADDITION
KEY PLAN
BUILDING
TOWER
F
G
H
LEGEND
FASCIA BASE
SEE MATCHLINE THIS PAGE
SCUPPER
ANTENNA MOUNT
RACEWAY
LIGHTS
OBSTRUCTION
DRAIN
ROOF
AIR TERMINALSHOOD
OUTER LIMIT OF ROOF WORK
INNER LIMIT OF ROOF WORK
SCALE: 1/8" = 1'-0"
8' 16'08'
3 3
SKYLIGHT
WALKWAY PAD
L
P
BALLASTED GUARDRAIL SYSTEM
UNDER THIS CONTRACT
LIMITS OF ATCT ROOF WORK
ACCU
AND STRAIRS
STEEL GRATING PLATFORM
LIGHT FIXTURE
SLOPE
SLOPESLOPE
A501
THIS PAGE
SEE MATCHLINE
SINGLE PLY ROOF
RETROFIT ROOF DRAINS WTH DRAIN GUARD FOR ALL DRAINS.
FURNISH AND INSTALL DURO-LAST, OR APPROVED EQUAL,
SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.5.
TO AVOID DAMAGE WITH NEW FASTENER INSTALLATION.
DECKING OF BUILDINGS. MARK OUT ON ROOF SIDE ACCORDINGLY
CONDUITS, BOXES, ETC., FASTENED TO UNDERSIDE OF METAL
CONTRACTOR MUST LOCATE ALL MEP UTILITIES, EQUIPMENT, 4.
ALL ROOFS DURING CONSTRUCTION.
PROTECTION SYSTEM (AIR TERMINALS, CONDUCTORS, ETC.) ON
REMOVE, MAINTAIN, AND REINSTALL EXISTING LIGHTNING 3.
WOOD BLOCKING SECUREMENT UPGRADES, AS REQUIRED.
CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL ALL
THE ROOFING MANUFACTURER'S INSTALLATION DETAILS.
AND ITS SECUREMENT COMPLIES WITH SAID CRITERIA, AND WITH
CERTIFICATION, WHICH INDICATES THAT THE WOOD BLOCKING
COORDINATE ROOFING MANUFACTURER'S INSPECTION AND
WOOD NAILERS AND SECUREMENT CRITERIA. CONTRACTOR MUST
WITH FACTORY MUTUAL LOSS PREVENTION DATA SHEET I-49,
EXISTING AND NEW WOOD BLOCKING/NAILERS MUST COMPLY 2.
FINISH MATERIALS.
OF NEW ROOF MEMBRANE. REINSTALL EXISTING EXTERIOR
PANEL SIDING, SCUPPERS, ETC.) AS REQUIRED FOR INSTALLATION
REMOVE EXISTING EXTERIOR FINISH MATERIAL (E.G., METAL 1.
DRAWINGS THAT CONTAIN DETAILS OF PANELS, RESPECTIVELY.
APPENDIX C FOR ADDITIONAL REQUIREMENTS AND AS-BUILT
INCHES THICK. SEE SPECIFICAITON SECTION 07 42 13 AND
AND A THICKNESS TO PROVIDE A FINISHED PANEL OF 1 1/2-
MEMBER. THE INSULATING CORE SHALL BE POLYISOCYANURATE
INCH THICK FIBRE REINFORCED CEMENT BOARD STABILIZING
THICK, MINIMUM, AND DARK BRONZE IIN COLOR. PROVIDE A 1/8-
FACE OF PANELS SHALL BE ANODIZED ALUMINUM, 0.063-INCHES
PANELS ABOVE AND BELOW ATCT CAB GLASS. EXTERIOR
FURNISH AND INSTALL NEW EXTERIOR INSULATED METAL
STEEL SCREWS AND FASTENERS, ONLY.
SECURE AND WEATHERPROOF NEW PANELS. USE STAINLESS
SILLS, COUNTERFLASHINGS, ETC., IN ORDER TO PROPERLY
BACKER ROD AND SEALANT, COMPRESSIBLE FIBERGLASS SHIMS,
ANODIZED ALUMINUM FRAMES AND STOREFRONT FITTINGS,
HARDWARE FOR INSULATED METAL PANELS. THIS INCLUDES
FURNISH AND INSTALL ALL NEW APPURTENANCES AND
MAXIMUM SLOPE IS 2V/12H FOR UL RATING.6.
PLATES.
GRAY IN COLOR, ATTACHED BY INDUCTION WELDING TO DURO-BOND
ONE (1) LAYER OF DURO-LAST PVC THERMOPLASTIC 60-MIL MEMBRANE, 5.
DURO-BOND PLATES AND #15 SCREWS.
ONE (1) LAYER OF 1/2-INCH DENSDECK ROOF BOARD ATTACHED WITH 4.
DRAINAGE. SEE KEYNOTES FOR VARYING THICKNESSES.
LAID. UTILIZE FLAT AND TAPERED BOARDS TO ACHIEVE PROPER
DURO-GUARD ISO III CG POLYISOCYANURATE INSULATION BOARD, LOOSELY
TWO (2) PERPINDICULAR LAYERS (TOP LAYER TAPERED CRICKETS) OF 3.
ONE (1) LAYER OF 5/8-INCH DENSDECK ROOF BOARD, LOOSELY LAID.2.
DURO-LAST VAPOR BARRIER OVER EXISTING STEEL DECKING. 1.
FOR 20-YEARS AND 130-MPH WIND LOADS.
EQUAL. SYSTEM SHALL BE DESIGNED, CERTIFIED AND WARRANTEED
BASIS OF DESIGN: DURO-LAST ROOFING SYSTEMS OR APPROVED
1/4" TO 4 1/4". MATCH EXISTING THICKNESSES.
BUILDING ROOF - 3 1/4" TO 7 1/4", AND ADDITION ROOF - 2
VARY AS FOLLOWS: ATCT ROOF - 2 1/4" TO 3 1/2", BASE
07 54 19. TAPERED CRICKET INSULATION BOARD THICKNESSES
ASSEMBLY NOTES ON THIS PAGE AND SPECIFICATON SECTION
ROOFS, AS INDICATED ON DRAWING. SEE STEEL DECK ROOFING
FROM INNER TO OUTER LIMITS ON ATCT AND ALL OTHER
ROOFING MEMBRANE, ROOF BOARD, INSULATION BOARD, ETC.,
PEDESTAL
A101 SCALE: 1/8" = 1'-0"
WALKWAY PATHS TO ROOF EQUIPMENT.
ROOF COLOR (GRAY) AND EXISTING MAINTENANCE
BY DURO-LAST OR APPROVED EQUAL. MATCH NEW
FURNISH AND INSTALL ROOF TRAK III WALKWAY PADS,
APPROVED EQUAL, AS INDICATED ON DRAWING.
BALLASTED GUARDRAIL SYSTEM, BY BLUEWATER OR
FURNISH AND INSTALL A SAFETYRAIL 2000
MANUFACTURER'S RECOMMENDATIONS.
AS NECESSARY TO WEATHERPROOF ROOF, PER
PEDESTAL), CURB, PENETRATION, PIPE, COUNTER FLASHINGS, ETC.,
FLASHING DETAILS SUCH AS INSIDE WALL TERMINATION (ATCT
/2
:1
:4
A
M lo tt e d b y
V
-C
-E
8 7 6 5 4 3 2 1
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
REDLINE
APVD
IS
orf-1402219-a101
2021-05-27T14:16:06-0400
SANDRA Luz Piettro
2021-05-27T10:54:27-0400
Jason Michael Neal
ORF-1402219-A501
A501 NOT TO SCALE
SNAP COPING CAP
JMN 1402219
PENETRATION INSTALLATIONS.
AND DETAILS FOR GENERAL, FIELD SEAM, COPING, EDGE, AND
FOLLOW DUROLAST, OR APPROVED EQUAL, SPECIFICATIONS 1.
05/24/2021
ROOF DETAILS
EL=
FIN. FLOOR
100'-0"
109'-0"
TO OF PARAPET
116'-0"
SOFFIT
T.O.S.
113'-4"
VARIES
112'-6"
MEMBRANE ROOFING
MEMBRANE FLASHING
PACK W/INS
ADHESIVE APPLICATION
3" RIGID INS
ACOUSTICAL PANELS
" GWB
MET STUDS
BATT INSUL
RESILIENT BASE
SCHEDULED FLOORING
VAPOR BARRIER
SEALANT
VAPOR BARRIER VAPOR BARRIER
VERTICAL BLINDS
SEE STRUCT.
WINDOW WALL SUPPORT-
5" PRECAST WALL PANELS
5" PRECAST PANELS
GRADE BEAM-
GWB
RIGID INSULATION RIGID INSULATION
EXTERIOR GYP. BOARD SOFFIT
ON MET. STUD FRAMING-
BATT. INSULATION
SUPPORT-
PRECAST PANEL
PRECAST MFR.
ATTACHMENT & REINF. BY
SEE C3.1 & C4.1
INFILTRATION DITCH-
SMACNA FIG. F
CONDUCTOR HEAD SIM. TO
FLASHING
w/THRU-WALL
PUBLIC WORKS DRAWING B-39
INFILTRATION TRENCH"
"STANDARD STORM WATER
CITY OF VIRGINIA BEACH
OVERFLOW DRAIN PER
EXPOSED GRADE BEAM
CHAMFER AT JOINT (TYP.)
A501 SCALE: 3/4" = 1'-0"
WALL SECTION 2
WALL SECTION 3
WALL SECTION
SCALE: 3/4" = 1'-0"
3'2'1'01'
:5 lo tt e
10"
3'-0"
1'-2" 1'-2"
2'-0"
1'-2" orf-1402219-a501
2021-05-27T14:16:42-0400
SANDRA Luz Piettro
2021-05-27T10:54:39-0400
Jason Michael Neal
VA NORFOLK
05/24/2021 1402219
ORF-1402219-A502
A502 NOT TO SCALE
INSIDE WALL TERMINATION1
ROOF DRAIN W/ DRAIN GUARD
PENETRATION INSTALLATIONS.
AND DETAILS FOR GENERAL, FIELD SEAM, COPING, EDGE, AND
FOLLOW DUROLAST, OR APPROVED EQUAL, SPECIFICATIONS 1.
RECTANGULAR PENETRATION 4
ROUND PENETRATION
:5 lo tt e
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
orf-1402219-a502
2021-05-27T14:17:05-0400
SANDRA Luz Piettro
2021-05-27T10:54:58-0400
Jason Michael Neal
SITE LAYOUT PLAN
ORF-1402219-C101
-c
STAGING AREA
CONTRACTOR
XX
X
FENCE
WATER LINES
A/C
DISCONNECT
FLAG POLE
ACCU1
PED
EMPTY
CONTROL
SEWAGE
SIDEWALK
C101 SCALE: 1" = 20'-0"
020' 20'
SCALE: 1" = 20'
40'
WHEELCHAIR
IL
LER
STO
RE
RO
AD
(S )U
MG
24.4
24.6
24.6
13'
PARKING
PARKING
PARKING WHEELCHAIR
RAMP
SLIDING
GATES
ENTRANCE
LB
.3
FENCE
GATE
BASE BLDG
WHEELCHAIR
-c lo tt e orf-1402219-c101
2021-05-27T14:17:36-0400
SANDRA Luz Piettro
2021-05-27T10:55:09-0400
Jason Michael Neal
ORF-1402219-D101
TOWER LINK
ACCU-3
ACCU-4
H-1
EF-6
EF-4
EF-5
ENGINE GEN.
H-2
H-4
CU-2
H-3
EF-2EF-3
CU-4
ACCU-2
ACCU-1
1 2 3 4 5
(TYP)
PIPE BOX
CU-3
PIPE EF-1
LEGEND
FASCIA BASE
D101 SCALE: 1/8" = 1'-0"
ROOF DEMOLITION PLAN
KEYNOTES
SEE MATCHLINE THIS PAGE
VANORFOLK
-d
ANTENNA MOUNT
RACEWAY
OBSTRUCTION
DRAIN
ROOF
AIR TERMINALSHOOD
SINGLE PLY ROOF
THIS PAGE
SEE MATCHLINE
OUTER LIMIT OF ROOF WORK
INNER LIMIT OF ROOF WORK
SCALE: 1/8" = 1'-0"
8' 16'08'
SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.8.
DOCUMENTATION TO COR.
METALS, ETC.) WHEN DISPOSING OF, AND PROVIDE
RECYCLE ALL RECYCLEABLE MATERIALS (E.G., SCRAP 7.
SEPARATE LINE ITEM FOR ABATEMENT COSTS.
REVIEW AND APPROVAL. CONTRACTOR SHALL PROVIDE A
PROVIDE STATE NOTIFICATION AND A PLAN FOR FAA
STATE OF VIRGINIA'S ASBESTOS CONTROL REGULATION, AND
MORE INFORMATION. CONTRACTOR SHALL ADHERE TO THE
AND DISPOSAL OF ASBESTOS CONTAINING MATERIALS, FOR
AND REGULATIONS. SEE SPECIFICATION 02 82 33, REMOVAL
ACCORDANCE WITH APPLICABLE LOCAL AND STATE RULES
TROWELED FLASHING CEMENT MUST BE ABATED IN
APPLIED FLASHING CEMENT. ALL HORIZONTAL FLASHING AND
EXISTING PARAPET WALL BASE FLASHING AND TROWEL
ASSUME ASBESTOS CONTAINING MATERIALS ARE PRESENT IN 6.
FOOT) TO REPAIR FIREPROOFING, IF NECESSARY.
CONTRACTOR SHALL PROVIDE UNIT PRICING ($/SQUARE 5.
ON ALL ROOFS DURING CONSTRUCTION.
PROTECTION SYSTEM (AIR TERMINALS, CONDUCTORS, ETC.)
REMOVE, MAINTAIN, AND REINSTALL EXISTING LIGHTNING 4.
BLOCKING/NAILER REPLACEMENT IN BID ($/BOARD FOOT).
CONTRACTOR SHALL FURNISH UNIT PRICE FOR WOOD
ACCORDANCE TO ROOFING MANUFACTURER'S SPECIFICATION.
DAMAGED WOOD BLOCKING UTILIZING FASTENERS IN
FOR DAMAGE, DRY ROT, PROPER FASTENERS, ETC. REPLACE
CONTRACTOR MUST INSPECT EXISTING WOOD BLOCKING
EXISTING WOOD BLOCKING/NAILERS/CLETES TO REMAIN. 3.
FOR ADDITIONAL INFORMATION.
MANUFACTURER'S RECOMMENDATIONS. SEE A-SERIES SHEETS
SEALANTS, ETC. REPLACE IN ACCORDANCE WITH
CAPPINGS, FLASHINGS, EXPANSION JOINTS, FILLER, REGLETS,
REMOVE AND DISPOSE OF ALL EXISTING PARAPET COPINGS, 2.
FOR NEW POLYISOCYANURATE RIGID INSULATION.
EXISTING METAL DECKING TO REMAIN. PREPARE SURFACE 1.
3 3
SKYLIGHT
WALKWAY PAD
UNDER THIS CONTRACT
LIMITS OF ATCT ROOF WORK
DISCREPANCIES, ETC., TO COR.
OF NEW INSULATED METAL PANELS. REPORT ANY DAMAGE,
METAL PANELS ALL AROUND, AND PREPARE FOR INSTALLATION
CLEAN AND INSPECT SUBSTRUCTURE OF EXTERIOR INSULATED
ACCU
AND STRAIRS
STEEL GRATING PLATFORM
PREPARE FOR REROOFING.
ON ALL ROOFS, ENTIRELY, AS INDICATED ON DRAWING.
PIPE PENETRATIONS, EXHAUST FAN PENETRATIONS, ETC.,
BOTTOMS OF ATCT PEDESTAL, AND ALL EQUIPMENT CURBS,
REMOVE AND DISPOSE OF ALL EXISTING FLASHING AROUND
LIGHT FIXTURE
SLOPESLOPE
D501
PEDESTAL
ELEVATIONS AND LOCATIONS OF PANELS.
SPECIFICATIONS FOR AS-BUILT DRAWINGS THAT CONTAIN
ACCESSIBLE FROM THE ATCT CATWALK. SEE APPENDIX C OF
PREPARE FOR NEW INSULATED PANELS. PANELS ARE
METAL PANELS ABOVE AND BELOW ATCT CAB GLASS AND
REMOVE AND DISPOSE OF ALL EXISTING EXTERIOR INSULATED
ROOFS.
REMOVE AND DISPOSE OF ALL EXISTING ROOF DRAINS ON ALL
INDICATED ON DRAWING. PREPARE FOR REROOFING.
BOARDS, AND INSULATION ON ALL ROOFS, ENTIRELY, AS
ROOF, AND ATCT (SINGLE-PLY) ROOF MEMBRANES, ROOF
(ROLLED ASPHALT) ROOF, BASE BUILDING ADDITION (MEMBRANE)
REMOVE AND DISPOSE OF ALL EXISTING BASE BUILDING
PREPARE FOR REROOFING.
COPING, REGLET, PITCH POCKETS, ETC., ON ALL ROOFS, AND
REMOVE AND DISPOSE OF ALL EXISTING TERMINATION BARS,
lo tt e orf-1402219-d101
2021-05-27T14:17:59-0400
SANDRA Luz Piettro
2021-05-27T10:55:19-0400
Jason Michael Neal
JMN 05/24/2021 1402219
ROOF DEMOLITION DETAILS
ORF-1402219-D501
113'-4"
VARIES
112'-6"
" GWB
MET STUDS
BATT INSUL
VAPOR BARRIER
VAPOR BARRIER VAPOR BARRIER
5" PRECAST WALL PANELS
GRADE BEAM-
RIGID INSULATION RIGID INSULATION
PRECAST MFR.
ATTACHMENT & REINF. BY
SEE C3.1 & C4.1
INFILTRATION DITCH-
SMACNA FIG. F
CONDUCTOR HEAD SIM. TO
FLASHING
w/THRU-WALL
PUBLIC WORKS DRAWING B-39
INFILTRATION TRENCH"
"STANDARD STORM WATER
CITY OF VIRGINIA BEACH
OVERFLOW DRAIN PER
CHAMFER AT JOINT (TYP.)
D501 SCALE: 3/4" = 1'-0"
WALL SECTION 2
WALL SECTION 3
WALL SECTION
METAL FLASHING
2 PIECE PARAPET CAP
ANCHOR BOLTS @3'-0" O.C.
CONT. CLEAT
4'-0" O.C.
LONG BOLTS MAX
ANCHOR NAILER
FASTENERS @ 2'-0" O.C.
CORROSION RESISTANT
PRECAST CONC
D501 SCALE: 1 1/2" = 1'-0"
DETAIL
NOT USED.1.
SCALE: 3/4" = 1'-0"
3'2'1'01'
SCALE: 1/2" = 1'-0"
5'1' 2'01' lo tt e
3'-0"
1'-2" 1'-2"
1'-2" orf-1402219-d501
2021-05-27T14:18:20-0400
SANDRA Luz Piettro
2021-05-27T10:55:35-0400
Jason Michael Neal
AND DRAWING LIST
COVER SHEET, VICINITY MAP,
ORF-1402219-G001
-g
VICINITY MAP
NOT TO SCALE
Shore Drive
Military Highway
Robin Hood Road
Azalea Garden Rd Miller Store Rd
E. Little
Creek Road
Bayside Rd
T OF TRANSPO
T A
IC
OF
STATES
IT
TM
EN
AVIA
I
LAR
TRAT
SI
NI
VIRGINIA BEACH, VIRGINIA
NORFOLK INTERNATIONAL AIRPORT
EASTERN SERVICE AREA
GENERAL
DRAWING NUMBER DRAWING TITLE
DRAWING LIST
CIVIL
DEMOLITION
ARCHITECTURAL
ORF-1402219-A502
ORF-1402219-A501
ORF-1402219-A101
ORF-1402219-D501
ORF-1402219-D101
ORF-1402219-C101
ORF-1402219-G002
ORF-1402219-G001
ROOF DEMOLITION DETAILS
CODES, STANDARDS, ETC.
SYMBOL LEGEND, ABBREVIATIONS, GENERAL NOTES,
AND DRAWING LIST
COVER SHEET, VICINITY MAP,
AIRPORT
INTERNATIONAL
PROJECT SITE AT
VIRGINIA BEACH, VA 23455
1245 MILLER STORE RD,
AND BASE BUILDING
TRAFFIC CONTROL TOWER
PROJECT SITE AT AIRPORT
:4 lo tt e orf-1402219-g001
2021-05-27T14:04:26-0400
SANDRA Luz Piettro
2021-05-27T10:53:58-0400
Jason Michael Neal
04' 4' 8'
SCALE: 1/4" = 1'-0"
020' 20'
SCALE: 1" = 20'
40'
AFF ABOVE FINISH FLOOR
ARCH ARCHITECT(URAL)
BM
CLG CEILING
CLR CLEAR
CONC CONCRETE
STL STEEL
STR STRUCTURAL
VERT VERTICAL
SIM SIMILAR
COR
VIF VERIFY IN FIELD
OC ON CENTER
TYP TYPICAL
& AND
@ AT
APC ACOUSTICAL PANEL CEILING
BEAM
SF SQUARE FEET
DEMO DEMOLITION
RE RESIDENT ENGINEER
DIAMETERDIA
HDW HARDWARE
HORIZ HORIZONTAL
HT HEIGHT
MECH MECHANICAL
NUMBER
ELEC ELECTRIC(AL)
EF
EQUIP EQUIPMENT
EXP EXPOSED
GWB GYPSUM WALLBOARD
FAA FEDERAL AVIATION ADMINISTRATION
DWG(S) DRAWING(S)
MIN MINIMUM
HM HOLLOW METAL
NO. #
SP STAIR PRESSURIZATION
DP DUST PROOF PARTITION
SSC SYSTEM SUPPORT CENTER
EXHAUST FAN
1.
2.
3. CONSTRUCTION TYPE:
OCCUPANCY CLASSIFICATION:
CODES APPLICABLE TO OTHER ASPECTS OF PROJECT:
LIFE SAFETY:
NFPA 101, EXISTING BUSINESS
GROUP B (BUSINESS)
TYPE II B
NON-BEARING WALLS:
ROOF:
FLOOR:
STRUCTURAL FRAME:
BEARING WALLS:
STAIRS:
SHAFTS:
THE FOLLOWING FIRE-RESISTANCE RATINGS ARE REQUIRED:
0 HOURS (IBC TABLE 601)
2 HOURS (IBC 707.3.2)
2 HOURS (IBC 707.3.1)
THROUGHOUT FACILITY.
FIRE ALARM: ADDRESSABLE FIRE ALARM SYSTEM PROVIDED
4.
5.
ABBREVIATIONSSYMBOL LEGEND GENERAL NOTES
APPLICABLE CODES, STANDARDS, & REGULATIONS
AND REGULATIONS:
STANDARDS,
APPLICABLE CODES,
DESCRIPTION
NOTES
DOOR REFERENCE
XXX
GRAPHIC SYMBOL
DRAWING NUMBER
DRAWING IS SHOWN
SHEET ON WHICH
DRAWING TITLE
SECTION NUMBER
SECTION IS DRAWN
SECTION
DETAIL NUMBER
DETAIL MARKER
DETAIL IS DRAWN
X001
MARKER
INTERIOR ELEVATIONELEVATION NUMBER
ELEVATION IS DRAWN
XXX DOOR NUMBER
ROOM NUMBER ROOM NAME/NUMBER
DESCRIPTION
EL.XXX
LEVEL LINE
X WALL TYPE
X REVISION NUMBER
X.XX
KEY NOTE REFERENCE
COLUMN REFERENCE
TRUE NORTH
PROJECT NORTH
PROJECT NORTH ARROW
TRUE NORTH ARROW
KEY NOTEX
X001 SCALE: 1" = XX'
TITLE TEXT
GFE GOVERNMENT FURNISHED EQUIPMENT
CONTRACTING OFFICER'S REPRESENTATIVE
EPDM ETHYLENE PROPYLENE DIENE MONOMER RUBBER
NIC NOT IN CONTRACT MEANS OF EGRESS SHALL NOT BE OBSTRUCTED THROUGHOUT PERFORMANCE OF THE WORK.14.
DISCONNECT SWITCHES, ETC.).
ONLY FAA SSC PERSONNEL MAY OPERATE ELECTRICAL DISTRIBUTION EQUIPMENT (I.E. CIRCUIT BREAKERS,13.
LEAST 10 WORKING DAYS PRIOR TO PERFORMING THE WORK.
TEMPORARY OUTAGES SHALL BE SCHEDULED AND APPROVED IN WRITING BY THE FAA SSC MANAGER AT UNSCHEDULED ELECTRICAL OUTAGES SHALL NOT BE PERMITTED. WORK THAT REQUIRES PERMANENT OR12.
PERFORMED TO THE SATISFACTION OF THE COR.
FACILITY CAUSED BY THEIR PERSONNEL AND/OR SUBCONTRACTORS. REPAIRS/RESTORATIONS SHALL BE THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR AND RESTORATION OF ANY DAMAGE TO THE11.
PROPERLY STORED AND/OR SECURED.
DEBRIS, COVERING PENETRATIONS DAILY, ETC. ALL DEBRIS SHALL BE REMOVED DAILY AND ALL TOOLS CONSIST OF, BUT NOT BE LIMITED TO, REMOVING ANY PROTECTIVE COVERINGS, REMOVING MISCELLANEOUS CONTRACTOR SHALL CLEAN THE WORK AREA(S) UPON COMPLETION OF EACH WORKDAY. CLEANING SHALL10.
IN ACCORDANCE WITH UNDERWRITERS LABORATORIES (UL) AND FAA STANDARDS.
THE DEMOLITION OR INSTALLATION WORK. MATERIALS AND METHODS USED FOR FIRESTOPPING SHALL BE FIRESTOP ALL OPENINGS IN FIRE-RESISTANCE RATED WALLS, CEILINGS, FLOORS, AND ROOFS CAUSED BY9.
CONSTRUCTION SEQUENCES.
IF NECESSARY, MAINTAIN HEPA FILTRATION OF CRITICAL AREAS DURING ALL ABATEMENT AND GENERAL CONSTRUCTION NOISE, DUST, AND DEBRIS MUST NOT INTERFERE WITH THE OPERATION OF THE FACILITY.8.
INSTALLED UNDER THIS CONTRACT.
PRIOR TO THE START OF WORK, VERIFY ROUGH-IN DIMENSIONS IN THE FIELD FOR ALL ITEMS TO BE7.
DRAWN IN FULL.
REPETITIVE FEATURES ARE NOT DRAWN IN THEIR ENTIRETY, AND SHALL BE COMPLETELY PROVIDED AS IF6.
COORDINATE CONTRACTOR ACCESS, PARKING, STAGING AREA, AND MATERIALS STORAGE WITH THE COR.5.
COORDINATED WITH THE COR AT LEAST 24-HOURS IN ADVANCE OF COMMENCING SAID WORK.
ANY WORK TO BE PERFORMED BY THE CONTRACTOR OUTSIDE OF COR'S DETERMINED SCHEDULE MUST BE HOWEVER, 3RD SHIFT NIGHT WORK WILL BE REQUIRED FOR ANY WORK IN THE CAB OR ON THE CAB ROOF.
UNLESS SPECIFIED OTHERWISE BY THE COR. HOURS OF WORK WILL BE DETERMINED BY THE COR IN FIELD;
WORK ONSITE SHALL BE LIMITED TO WEEKDAYS, MONDAY THROUGH FRIDAY EXCLUDING HOLIDAYS,4.
DISRUPTION, IMPACT OR DELAY TO THE OTHER WORK/CONTRACTS.
TIME AS THIS CONTRACT. THE CONTRACTOR SHALL COORDINATE THEIR WORK IN ORDER TO MINIMIZE OTHER WORK/CONTRACTS MAY BE UNDERWAY AT THE ATCT AND/OR BASE BUILDING DURING THE SAME3.
THEIR IMPACT, IF ANY, ON THE OPERATION OF THE FACILITY.
BEFORE A NOTICE TO PROCEED IS ISSUED. THE SCHEDULE SHALL OUTLINE ALL PHASES OF THE WORK AND THE CONTRACTOR SHALL PROVIDE A COMPREHENSIVE SCHEDULE TO THE COR FOR REVIEW AND APPROVAL2.
WITH THE COR.
(COR) TO BE DISRUPTIVE OR UNSAFE SHALL BE STOPPED IMMEDIATELY. RESCHEDULE THE STOPPED WORK ACCIDENTS AND/OR LOSS OF LIFE. ANY WORK DETERMINED BY THE CONTRACTING OFFICER'S REPRESENTATIVE AIRPORT TRAFFIC CONTROL TOWER. ANY UNAUTHORIZED ELECTRICAL OUTAGE MAY CAUSE AIRCRAFT THE CONSTRUCTION OF THIS PROJECT MUST NOT INTERFERE WITH THE 24-HOUR OPERATION OF THE1.
MEP MECHANICAL, ELECTRICAL, & PLUMBING
RADAR RADIO DETECTION AND RANGING
ASDE AIRPORT SURFACE DETECTION EQUIPMENT
GRAPHIC SCALE
ARCHITECTURAL
GRAPHIC SCALE
ENGINEERING
THE SHEET IS REDUCED IN SIZE.
FULL SIZE AND FOR USING THE APPROPRIATE BAR SCALE WHEN
- 22" X 34" DRAWING SHEET SIZE), AND ARE USED FOR SCALING AT
NOTE: THE ABOVE SCALES REFER TO FULL SIZE DRAWINGS (ANSI D
VIRGINIA ENERGY CONSERVATION CODE, 2015 EDITION
UL 96A - STANDARD FOR INSTALLATION REQUIREMENTS FOR LIGHTNING PROTECTION SYSTEMS, 13TH EDITION
UL 96 - ANSI/CAN/UL STANDARD FOR SAFETY LIGHTNING PROTECTION COMPONENTS, 6TH EDITION
NFPA 780 - STANDARD FOR THE INSTALLATION OF LIGHTNING PROTECTION SYSTEMS, 2017 EDITION
REQUIREMENTS FOR FACILITIES AND ELECTRONIC EQUIPMENT
FAA-STD-019F - LIGHTNING AND SURGE PROTECTION, GROUNDING, BONDING, AND SHIELDING
NFPA 70 - NATIONAL ELECTRICAL CODE (NEC), 2017 EDITION
OSHA CFR 29 1926 - CONSTRUCTION
OSHA CFR 29 1910 - GENERAL INDUSTRY
(CFR) 1960.20 - ALTERNATE STANDARD FOR FIRE SAFETY IN AIRPORT TRAFFIC CONTROL TOWERS
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) 29 CODE OF FEDERAL REGULATIONS
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101 - LIFE SAFETY CODE, 2018 EDITION
VIRGINIA STATEWIDE FIRE PREVENTION CODE, 2015 EDITION
VIRGINIA EXISTING BUILDING CODE, 2015 EDITION
VIRGINIA CONSTRUCTION CODE, 2015 EDITION
ASCE 7-16 LOADING CRITERIA:
STRENGTH DESIGN WIND LOAD FACTOR: 1.0
INTERNAL PRESSURE COEFFICIENT: 0.18
WIND IMPORTANCE FACTOR: 1.15
OCCUPANCY/RISK CATEGORY: III
EXPOSURE: C
BASIC WIND SPEED: 140-MPH
BUILDING HEIGHT: APPROX. 128-FT (TOP OF CAB ROOF) ABOVE GROUND LEVEL
NOTES, CODES, STANDARDS, ETC.
SYMBOL LEGEND, ABBREVIATIONS, GENERAL
ORF-1402219-G002
:3 lo tt e orf-1402219-g002
2021-05-27T14:14:21-0400
SANDRA Luz Piettro
2021-05-27T10:54:13-0400
Jason Michael Neal