8-26-0924 KC Assessors Office Renovation Revision 1 (MEP).pdf

PDF 7 MB Posted

Attached to
NS27-108 Kane County - Construction Services Remodel Projects
Solicitation number
NS27-108
Issued by
Duchesne County, Utah

About this file

This document comprises mechanical and electrical construction drawings and specifications for the Kane County Assessors Office Renovation project located at 180 W 300 N, Kanab, Utah 84741, prepared by Iron Rock Group. The project involves comprehensive HVAC (heating, ventilation, and air conditioning) system installation and electrical work including lighting, receptacles, switches, fire alarm systems, and related infrastructure. The mechanical scope includes supply and return ductwork, exhaust fans, condensing units (Carrier 27TPA836A003 and 27TPA848A003), fan coil units with auxiliary heating, diffusers, grilles, and associated controls and dampers. The electrical scope encompasses panelboard installation with multiple circuits for lighting, receptacles, motors, heating equipment, and HVAC connections, with provisions for three options regarding existing electrical panel relocation and replacement. The project is governed by the 2021 International Mechanical Code and 2020 National Electrical Code, with design criteria including an elevation of 4,553 feet above sea level, winter design temperature of 26.6°F, and summer design temperature of 106.3°F. A pre-bid conference and site walk-through was held on September 14, 2026, at 10:00 AM, with final RFI questions due October 5, 2026, by 5:00 PM. Per Addendum #1, sealed bid proposals are due October 9, 2026, at 12:00 PM at Kane County Clerk's office, 76 N Main Street, Kanab, Utah 84741, with bid opening occurring immediately thereafter.

The specification documents detail extensive requirements for materials, workmanship, testing, and quality assurance. All mechanical equipment, piping, and ductwork must comply with NFPA, ASHRAE, and SMACNA standards, with galvanized sheet metal ductwork, fiberglass lining for acoustic control, and comprehensive fire stopping at all penetrations through fire-rated assemblies. Electrical work requires copper conductors rated 75°C minimum, UL-listed equipment, and compliance with NEC standards, including GFCI protection and proper grounding throughout. The contractor must provide shop drawings for approval prior to fabrication, coordinate work across all trades, and complete a comprehensive test and balance of the HVAC system by an independent, AABC and NEBB-certified agency. All equipment must carry one-year guarantees covering materials and workmanship, with submittals including manufacturer certification data, operation and maintenance manuals, warranty documentation, spare parts lists, and as-built drawings. The project requires performance bonds, compliance with all applicable local, state, and federal codes, and coordination with utility company requirements for electrical service.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES

T

F

DD

F

M

S

LEGEND

MECHANICAL CALL-OUTS

CODES & DESIGN CRITERIA

SHEET:

IRON ROCK

GROUP

Building on Solid Foundations

460 E. 300 SOUTH

KANAB, UTAH 84741

435-644-2031 www.ironrockeng.com

R

EV

SCALE:

DRAWN BY:

IN

IT

IA

L

SU

B

M

IT

TA

L:

D A

TE

D

ES

C R

IP

TI

O N

R

EV

IS

IO

N

9/

/2

© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,

DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL

PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS

AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE

COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS

AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION, DISTRIBUTION,

PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN WHOLE OR IN

PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM IRON ROCK

GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS PROHIBITED.

W . 3

N

. K

AN

AB

, U

TA

H

KA

N

E C

O U

N

TY

A

SS

ES

SO

R S

O

FF

IC

E

R

EN

O

VA

TI

O

N 9/

8/

THOMAS W.

AVANT

#5561917

RE

E

NI

G

NE

LANOISSEFORP

DERETSI G E R

STATE OF U TAH

Thomas Avant

9/24/2026

M0.1

NTS

GA

M

EC

H

AN

IC

AL

C O

VE

R

SH

EE

T

AutoCAD SHX Text

1. DO NOT SCALE DRAWINGS. DO NOT SCALE DRAWINGS. 2. CONTRACTOR SHALL COORDINATE WORK INDICATED HEREIN W / PLUMBING , ELECTRICAL & FIRE PROTECTION CONTRACTOR SHALL COORDINATE WORK INDICATED HEREIN W / PLUMBING , ELECTRICAL & FIRE PROTECTION SECTIONS. SUBMIT 1/4" SCALE SHOP DRAWINGS FOR DUCT SYSTEMS, DIMENSIONED TO INCORPORATE THE WORK OF OTHER TRADES. INDICATE SPACES RESERVED FOR FIRE SPRINKLER, PIPING & ELECTRICAL CONDUIT MAINS. 3. UNLESS NOTED OTHERWISE, BRANCH DUCTS TO INDIVIDUAL TERMINALS, DIFFUSERS AND GRILLS SHALL BE SAME UNLESS NOTED OTHERWISE, BRANCH DUCTS TO INDIVIDUAL TERMINALS, DIFFUSERS AND GRILLS SHALL BE SAME SIZE AS NECK INLET. 4. PROVIDE EQUIPMENT SCHEDULED OR INDICATED ON THE DRAWINGS BUT NOT INCLUDED WITHIN THE SPECIFICATIONS. PROVIDE EQUIPMENT SCHEDULED OR INDICATED ON THE DRAWINGS BUT NOT INCLUDED WITHIN THE SPECIFICATIONS. INSTALLATION SHALL CONFORM TO MANUFACTURERS RECOMMENDATIONS AND APPLICABLE CODES. PROVIDE SUBMITTALS. 5. ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPMENT SHALL BE VERIFIED WITH ELECTRICAL DRAWINGS PRIOR ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPMENT SHALL BE VERIFIED WITH ELECTRICAL DRAWINGS PRIOR TO EQUIPMENT ORDER RELEASE. ADDITIONAL ELECTRICAL WORK RESULTING FROM EQUIPMENT SUBSTITUTIONS IS THE RESPONSIBILITY OF THE CONTRACTOR. 6. LENGTH OF FLEXIBLE DUCTWORK SHALL BE LIMITED TO 5'-0" MAX. HORIZONTAL RUN WITH ONLY ONE 90 ELL. LENGTH OF FLEXIBLE DUCTWORK SHALL BE LIMITED TO 5'-0" MAX. HORIZONTAL RUN WITH ONLY ONE 90° ELL.PERMITTED. SECURE FLEXIBLE DUCTWORK WITH SCREWS & DRAWBANDS. 7. DUCT SIZES INDICATED ARE NET INSIDE CLEAR DIMENSIONS. DUCT SIZES INDICATED ARE NET INSIDE CLEAR DIMENSIONS. 8. PROVIDE CEILING OPERATORS FOR INACCESSIBLE M.V.D.'S WHERE INDICATED, EQUAL TO YOUNG REGULATOR, REMOTE PROVIDE CEILING OPERATORS FOR INACCESSIBLE M.V.D.'S WHERE INDICATED, EQUAL TO YOUNG REGULATOR, REMOTE GEAR OPERATED, WITH CEILING ESCUTCHEON. 9. ITEM DESIGNATIONS INDICATED HEREIN ARE FOR PURPOSES OF THESE DOCUMENTS ONLY. CONTRACTOR SHALL ITEM DESIGNATIONS INDICATED HEREIN ARE FOR PURPOSES OF THESE DOCUMENTS ONLY. CONTRACTOR SHALL VERIFY W/ OWNERS REPRESENTATIVE ACTUAL "TAGGING" INFORMATION TO BE PROVIDED FOR EACH ITEM OF MECHANICAL EQUIP. PRIOR TO NAMEPLATE ORDER RELEASE. 10. CEILING DIFFUSERS SHALL BE 36" MIN. FROM CEILING MOUNTED SMOKE DETECTORS. COORDINATE W/ ELECTRICAL CEILING DIFFUSERS SHALL BE 36" MIN. FROM CEILING MOUNTED SMOKE DETECTORS. COORDINATE W/ ELECTRICAL DIVISION. 11. SECURE DIFFUSERS AND GRILLS TO T-BAR CEILINGS, WHERE APPLICABLE. SUBMIT SHOP DRAWINGS FOR APPROVAL SECURE DIFFUSERS AND GRILLS TO T-BAR CEILINGS, WHERE APPLICABLE. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO BEGINNING WORK. 12. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR ACTUAL LOCATION OF GRILLS & DIFFUSERS IN CEILING, REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR ACTUAL LOCATION OF GRILLS & DIFFUSERS IN CEILING, AS WELL AS ACCESS DOORS. 13. COORDINATE EQUIPMENT DIMENSIONS AND LAYOUT W/ PLUMBING SECTION WHERE FLOOR SINKS ARE INDICATED. COORDINATE EQUIPMENT DIMENSIONS AND LAYOUT W/ PLUMBING SECTION WHERE FLOOR SINKS ARE INDICATED. 14. PIPES PASSING THRU FIRE RATED WALLS & FLOORS SHALL BE SEALED WITH U.L. LISTED MATERIAL EQUAL TO 3M PIPES PASSING THRU FIRE RATED WALLS & FLOORS SHALL BE SEALED WITH U.L. LISTED MATERIAL EQUAL TO 3M FIRE BARRIER, CAULK OR PUTTY. SEALANT'S RATING SHALL MATCH THE RATING OF THE ASSEMBLY. 15. PROVIDE VALVE TAGS AND PIPE IDENTIFICATION BANDS. TAGS SHALL BE BRASS W/ CHAIN. IDENTIFICATION BANDS PROVIDE VALVE TAGS AND PIPE IDENTIFICATION BANDS. TAGS SHALL BE BRASS W/ CHAIN. IDENTIFICATION BANDS SHALL BE LOCATED EVERY 25 FEET AND ON EITHER SIDE OF INTERMEDIATE BARRIER. 16. PROVIDE 18" X 18" MIN, ACCESS DOOR IN INACCESSIBLE CEILINGS AND WALLS FOR EQUIPMENT REQUIRING ACCESS PROVIDE 18" X 18" MIN, ACCESS DOOR IN INACCESSIBLE CEILINGS AND WALLS FOR EQUIPMENT REQUIRING ACCESS OR ADJUSTMENT. COORDINATE LOCATIONS AND SUBMIT TO ARCHITECT FOR APPROVAL PRIOR TO BEGINNING WORK. 17. TURNING VALVE RUNNERS SHALL HAVE A VANE IN EVERY SLOT IN STRICT CONFORMANCE WITH MFR'S INSTRUCTIONS TURNING VALVE RUNNERS SHALL HAVE A VANE IN EVERY SLOT IN STRICT CONFORMANCE WITH MFR'S INSTRUCTIONS AND SMACNA DUCT CONSTRUCTION STANDARDS. 18. VERIFY FIT OF DUCTWORK AND PIPING PRIOR TO FABRICATION. VERIFY FIT OF DUCTWORK AND PIPING PRIOR TO FABRICATION. 19. INSULATED PIPING EXPOSED TO VIEW (THROUGHOUT THE FACILITY) SHALL BE COVERED FINISHED W/ PVC JACKET INSULATED PIPING EXPOSED TO VIEW (THROUGHOUT THE FACILITY) SHALL BE COVERED FINISHED W/ PVC JACKET EQUAL TO MANVILLE PVC / PERMA-WELD PIPE JACKETING SYSTEM USING 30 MIL THICK JACKET. FITTINGS, FLANGES, VALVES & ACCESSORIES SHALL BE JACKETED. INSTALL PER MANUFACTURER'S INSTRUCTIONS W/ SEAM ON TOP OF PIPE SO AS NOT TO BE VISIBLE FROM OCCUPIED SPACE. 20. DUCTWORK LOCATED BELOW 7'-6" IN MECHANICAL ROOMS SHALL BE EQUIPPED W/PADDING MATERIAL ON ALL DUCTWORK LOCATED BELOW 7'-6" IN MECHANICAL ROOMS SHALL BE EQUIPPED W/PADDING MATERIAL ON ALL CORNERS, EDGES & OTHER SURFACES WHICH MAY BE HAZARDOUS. 21. COORDINATE & VERIFY ACTUAL APPROVED EQUIPMENT DIMENSIONS PRIOR TO POURING EQUIPMENT PADS. COORDINATE & VERIFY ACTUAL APPROVED EQUIPMENT DIMENSIONS PRIOR TO POURING EQUIPMENT PADS. 22. DUCT MOUNTED SMOKE DETECTORS SHALL BE ZERO VELOCITY TYPE WHERE INDICATED ON DRAWINGS. DUCT MOUNTED SMOKE DETECTORS SHALL BE ZERO VELOCITY TYPE WHERE INDICATED ON DRAWINGS. 23. DRAIN PIPING FROM A.C. EQUIPMENT SHALL BE ROUTED SO AS NOT TO CREATE A TRIPPING HAZARD. COORDINATE DRAIN PIPING FROM A.C. EQUIPMENT SHALL BE ROUTED SO AS NOT TO CREATE A TRIPPING HAZARD. COORDINATE ACTUAL DRAIN CONNECTIONS WITH PLUMBING SECTION. COORDINATE FLOOR SINK LOCATIONS ACCORDINGLY. 24. CONDENSATE DRAIN TRAPS SHALL BE 3" DEEP MINIMUM. CONDENSATE DRAIN TRAPS SHALL BE 3" DEEP MINIMUM. 25. COORDINATE ALL CHASE, SLEEVE, AND SLAB BLOCK-OUT REQUIREMENTS BEFORE CONCRETE IS POURED OR BLOCK COORDINATE ALL CHASE, SLEEVE, AND SLAB BLOCK-OUT REQUIREMENTS BEFORE CONCRETE IS POURED OR BLOCK IS SET. 26. PROVIDE ACCESS DOOR IN DUCTWORK UPSTREAM OF EACH REHEAT COIL.. PROVIDE ACCESS DOOR IN DUCTWORK UPSTREAM OF EACH REHEAT COIL.. 27. DUCTWORK VISIBLE BEHIND DIFFUSERS, REGISTERS, OR GRILLS SHALL BE PAINTED FLAT BLACK. DUCTWORK VISIBLE BEHIND DIFFUSERS, REGISTERS, OR GRILLS SHALL BE PAINTED FLAT BLACK. 28. REFER TO EQUIPMENT DRAWINGS, SPECIFICATIONS, & SHOP DRAWINGS FOR CONNECTIONS TO EQUIPMENT. REFER TO EQUIPMENT DRAWINGS, SPECIFICATIONS, & SHOP DRAWINGS FOR CONNECTIONS TO EQUIPMENT. 29. MANUAL VOLUME DAMPERS AND VALVES ON INSULATED DUCTWORK AND PIPING SHALL HAVE EXTENDED STEMS TO MANUAL VOLUME DAMPERS AND VALVES ON INSULATED DUCTWORK AND PIPING SHALL HAVE EXTENDED STEMS TO ALLOW FOR THE INSULATION THICKNESS. PROVIDE MIN 12" LONG RED RIBBON QUADRANT LOCATOR ON VOLUME DAMPER HANDLES. 30. CONTRACTOR TO NOTIFY ENGINEER OF ANY INCORRECT ASSUMPTIONS PRIOR TO STARTING ANY WORK. CONTRACTOR TO NOTIFY ENGINEER OF ANY INCORRECT ASSUMPTIONS PRIOR TO STARTING ANY WORK. 31. ALL DIFFUSER GRILLS/REGISTERS SHALL HAVE MANUALLY ADJUSTABLE DAMPERS INSTALLED IN DUCT IMMEDIATELY ALL DIFFUSER GRILLS/REGISTERS SHALL HAVE MANUALLY ADJUSTABLE DAMPERS INSTALLED IN DUCT IMMEDIATELY PRIOR GRILL FOR SYSTEM BALANCING. 32. ALL CEILING HUNG UNITS TO BE ATTACHED TO FLOOR SYSTEM WITH VIBRATION DAMPING MOUNTS. ALL CEILING HUNG UNITS TO BE ATTACHED TO FLOOR SYSTEM WITH VIBRATION DAMPING MOUNTS. 33. ROOF TOP EQUIPMENT TO BE INSTALLED A MINIMUM OF 10' FROM THE ROOF EDGE, ROOF TOP EQUIPMENT TO BE INSTALLED A MINIMUM OF 10' FROM THE ROOF EDGE, OR HAVE A GUARD INSTALLED WHICH IS A MINIMUM 42" TALL AND EXTENDS A MINIMUM OF 30" BEYOND EACH EDGE OF EQUIPMENT OR HAVE INSTALLED FALL/ARREST RESTRAINT ANCHORAGE CONNECTOR (IN COMPLIANCE WITH ANSI/ASSE Z 359.1).

AutoCAD SHX Text

XX

AutoCAD SHX Text

XX

AutoCAD SHX Text

-TYPE -UNIT CALL-OUT

AutoCAD SHX Text

EQUIPMENT

AutoCAD SHX Text

XX

AutoCAD SHX Text

XX

AutoCAD SHX Text

-TYPE -FLOW (CFM) -SIZE

AutoCAD SHX Text

DUCT TERMINATION

AutoCAD SHX Text

XXXX

AutoCAD SHX Text

T-STAT

AutoCAD SHX Text

THERMOSTAT

AutoCAD SHX Text

FLFD

AutoCAD SHX Text

FUSIBLE LINK FIRE DAMPER

AutoCAD SHX Text

DD

AutoCAD SHX Text

DUCT MOUNTED SMOKE DETECTOR

AutoCAD SHX Text

FSDT-STAT

AutoCAD SHX Text COMBINATION FIRE/ SMOKE DETECTOR (GREENHAECK CFSD-211/ SEE DETAIL 12, SHEET M201)

AutoCAD SHX Text

AUTO D

AutoCAD SHX Text

MOTORIZED DAMPER

AutoCAD SHX Text

MVD

AutoCAD SHX Text

MANUAL VOLUME DAMPER

AutoCAD SHX Text

SA

AutoCAD SHX Text

SUPPLY AIR

AutoCAD SHX Text

RA

AutoCAD SHX Text

RETURN AIR

AutoCAD SHX Text

EA

AutoCAD SHX Text

EXHAUST AIR

AutoCAD SHX Text

OA

AutoCAD SHX Text

OUTSIDE AIR

AutoCAD SHX Text

EF

AutoCAD SHX Text

EXHAUST FAN

AutoCAD SHX Text

HVAC SHAFTS

AutoCAD SHX Text

SUPPLY DUCT - NEW

AutoCAD SHX Text

SUPPLY DUCT - EXISTING

AutoCAD SHX Text

SUPPLY DUCT - DEMO

AutoCAD SHX Text

RETURN DUCT - NEW

AutoCAD SHX Text

RETURN DUCT - EXISTING

AutoCAD SHX Text

RETURN DUCT - DEMO

AutoCAD SHX Text

EXHAUST DUCT - NEW

AutoCAD SHX Text

EXHAUST DUCT - EXISTING

AutoCAD SHX Text

EXHAUST DUCT - DEMO

AutoCAD SHX Text

JURISDICTION:

AutoCAD SHX Text

KANAB, UTAH

AutoCAD SHX Text

MECHANICAL CODE:

AutoCAD SHX Text

2021 INTERNATIONAL MECHANICAL CODE

AutoCAD SHX Text

ENERGY CODE:

AutoCAD SHX Text

2021 INTERNATIONAL ENERGY CODE

AutoCAD SHX Text

ELEVATION:

AutoCAD SHX Text

4,553 FT. ABOVE SEA LEVEL

AutoCAD SHX Text

WINTER DESIGN DB:

AutoCAD SHX Text

26.6 DEG. F.

AutoCAD SHX Text

SUMMER DESIGN TEMP DB/ WAB:

AutoCAD SHX Text

106.3 DEG. F. / 66.2 DEG. F.

AutoCAD SHX Text

DB DESIGN FOR AIR COOLED EQUIPMENT:

AutoCAD SHX Text

93.6 DEG. F.

MECHANICAL SPECIFICATIONS

M0.2

NTS

I.R.

M

EC

H

AN

IC

AL

SP

EC

IF

IC

AT

IO

N S

SHEET:

IRON ROCK

GROUP

Building on Solid Foundations

460 E. 300 SOUTH

KANAB, UTAH 84741

435-644-2031 www.ironrockeng.com

R

EV

SCALE:

DRAWN BY:

IN

IT

IA

L

SU

B

M

IT

TA

L:

D A

TE

D

ES

C R

IP

TI

O N

R

EV

IS

IO

N

9/

/2

© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,

DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL

PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS

AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE

COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS

AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION, DISTRIBUTION,

PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN WHOLE OR IN

PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM IRON ROCK

GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS PROHIBITED.

W . 3

N

. K

AN

AB

, U

TA

H

KA

N

E C

O U

N

TY

A

SS

ES

SO

R S

O

FF

IC

E

R

EN

O

VA

TI

O

N 9/

8/

THOMAS W.

AVANT

#5561917

RE

E

NI

G

NE

LANOISSEFORP

DERETSI G E R

STATE OF U TAH

Thomas Avant

9/24/2026

AutoCAD SHX Text GENERAL SPECIFICATIONS 1. SCOPE: PROVIDE ALL MATERIALS, LABOR, TOOLS AND INCIDENTALS NECESSARY TO INSTALL AND MAKE READY FOR OWNER'S USE COMPLETE SYSTEMS OF HEATING, VENTILATION, AIR CONDITIONING (HVAC), PLUMBING, FOR THE PROPOSED WORK AND BUILDING RENOVATIONS AS SHOWN ON THE DRAWINGS AND CALLED FOR IN THESE SPECIFICATIONS. VISIT THE SITE TO OBTAIN DIMENSIONS, EXISTING LAYOUTS AND LOCATIONS AND EXISTING CONSTRUCTION DETAILS NOT SHOWN ON THESE DRAWINGS. 2. BIDDERS RESPONSIBILITY: EXAMINE THE DRAWINGS AND SPECIFICATIONS AND VISIT THE WORK SITE. BECOME FAMILIAR WITH THE CHARACTER OF THE WORK, THE COORDINATION WITH OTHER TRADES REQUIRED, AND ANY OTHER CONDITIONS THAT AFFECT THE COMPLETION OF THIS WORK. 3. PERMITS, CODES AND LAWS: APPLY FOR ALL PERMITS AND PAY ALL FEES. ALL WORK SHALL BE IN ACCORDANCE WITH LATEST EDITIONS OF THE FOLLOWING RULES AND REGULATIONS, HEREIN REFERRED TO AS "CODES": THE LATEST OR ADOPTED EDITION OF THE APPLICABLE LOCAL, STATE, AND FEDERAL BUILDING, MECHANICAL, SANITATION, PLUMBING, ETC. CODES. UNDERWRITERS LABORATORIES, INC. (U.L.) NATIONAL FIRE PROTECTION ASSOCIATION (N.F.P.A.) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (O.S.H.A.) WHERE ANY OF THESE CODES ARE AT VARIANCE WITH THE DRAWINGS AND SPECIFICATIONS, THEIR REQUIREMENTS SHALL TAKE PRECEDENCE, UNLESS THE DRAWINGS AND SPECIFICATIONS REQUIREMENTS EXCEED THESE CODES. INCLUDE ANY COST NECESSARY TO MEET THESE CODES IN THE BID PRICE. 4. MECHANICAL PLANS: THE MECHANICAL PLANS ARE DIAGRAMMATIC AND BASED ON ONE MANUFACTURER'S EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN IT'S EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE DETAILS OF THE EQUIPMENT. VERIFY THE ACTUAL DIMENSIONS OF THE EQUIPMENT PROPOSED TO BE USED. INSTALLATION SHALL BE WITHIN THE LIMITATIONS IMPOSED BY THE ARCHITECTURAL, STRUCTURAL, HVAC, ELECTRICAL, AND PLUMBING REQUIREMENTS WITH ADEQUATE SPACE FOR MAINTENANCE. 5. QUESTIONS AND CLARIFICATIONS OF BID DOCUMENTS: BIDDERS SHALL NOT RELY ON ANY ORAL CLARIFICATION OF THE DRAWINGS OR SPECIFICATIONS. ANY QUESTIONS OR CLARIFICATIONS SHALL BE REFERRED IN WRITING TO THE ARCHITECT. 6. GUARANTEES: ALL EQUIPMENT, MATERIALS, AND WORKMANSHIP SHALL BE GUARANTEED IN WRITING FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE. WARRANTIES SHALL BE IN WRITING AND SHALL INCLUDE FACTORY WARRANTIES FOR EACH PIECE OF EQUIPMENT. PROVIDE A CERTIFICATE FOR EACH PIECE OF EQUIPMENT. CLEARLY INDICATE ON EACH THE MODEL NO., SERIAL NO., LOCATION, AND OWNER'S NAME. 7. COMPLETE SYSTEM: ALL PRODUCTS, MATERIALS AND ACCESSORIES SHALL BE FURNISHED AND INSTALLED AS REQUIRED FOR A COMPLETE SYSTEM READY FOR OWNER;S BENEFICIAL USE. 8. WORKMANSHIP: ALL WORK SHALL BE PERFORMED BY COMPETENT MECHANICS USING PROPER TOOLS AND EQUIPMENT TO PRODUCE FIRST QUALITY WORK. ALL WORK SHALL BE NEATLY INSTALLED, ACCESSIBLE FOR MAINTENANCE, AND COMPLETE WITH ALL ACCESSORIES REQUIRED. 9. ACCESSIBILITY: INSTALL ALL EQUIPMENT AND THEIR APPURTENANCES SUCH AS, BUT NOT LIMITED TO, VALVES, COILS, DRAIN PANS, DRAINS, DAMPERS, CONTROLS, MOTORS, CONTROLLERS, ETC., SO THAT THEY CAN BE SERVICED, RESET, REPLACED OR RE-CALIBRATED, ETC. INSTALL ALL NECESSARY ACCESS PANELS AND BUILDING ACCESS DOORS, AS BELOW WHERE REQUIRED TO ACCOMPLISH THIS. IF ANY EQUIPMENT OR COMPONENTS DO NOT FIT WHERE INTENDED, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING, REQUESTING FURTHER GUIDANCE, PROVIDE BUILDING ACCESS DOORS FOR ALL MECHANICAL EQUIPMENT REQUIRING SERVICE, INCLUDING BUT NOT LIMITED TO, AHU'S, FANS, DAMPERS, DUCT ACCESS PANELS, CONTROLS, PIPING, VALVES, REGULATORS, TRAPS, ETC. INSTALLED ABOVE HARD CEILINGS, BEHIND WALLS, AND BELOW FLOORS, FOR INSTALLATION BY OTHER DIVISIONS OF THE WORK. BUILDING ACCESS DOORS ARE NOT REQUIRED WHERE THE MECHANICAL EQUIPMENT IS INSTALLED ABOVE LAY-IN AND ACCESSIBLE SPLINE CEILINGS. OTHER TYPES OF SPLINE CEILINGS REQUIRE BUILDING ACCESS DOORS. SIZE THE BUILDING ACCESS DOORS FOR THE USE INTENDED, BUT NOT LESS THAT 12 INCHES BY 12 INCHES. WHERE HUMAN ACCESS IS REQUIRED, PROVIDE 24 INCHES BY 24 INCHES, OR LARGER. WHERE BUILDING ACCESS DOORS CANNOT BE INSTALLED FOR STRUCTURAL OR ARCHITECTURAL REASONS, NOTIFY THE ARCHITECT. PRIME COAT BUILDING ACCESS DOORS IN PAINTED AREAS WITH FINISH PAINTING AS SPECIFIED IN OTHER DIVISIONS. IN WET AREAS, TOILET ROOMS OR AREAS WITH CERAMIC TILE FLOORS OR WALLS, PROVIDE STAINLESS STEEL BUILDING ACCESS DOORS. PROVIDE BUILDING ACCESS DOORS WITH A CONCEALED KEY OPERATED LOCK AND CONCEALED HINGES. ALL LOCKS SHALL BE KEYED ALIKE. PROVIDE BUILDING ACCESS DOORS AS SPECIFIED IN OTHER DIVISIONS OF THE WORK OR PROVIDE MILCOR DOORS, OR EQUIVALENT, SUITABLE FOR THE INSTALLATION INTENDED. PROVIDE FIRE RATED DOORS FOR ALL FIRE RATED WALL PARTITIONS, AND CEILINGS. 10. WORK BY OTHER TRADES: FURNISH ALL SLEEVE FRAMES, BUILDING ACCESS DOORS, PREFABRICATED EQUIPMENT CURBS, ROOF CURBS, ETC. FOR INSTALLATION BY OTHER TRADES. INSTALL ALL MOTORS AND FURNISH THE STARTING EQUIPMENT AND DISCONNECTS TO THE ELECTRICAL SUBCONTRACTOR FOR INSTALLATION. CONTROL WIRING, INCLUDING SWITCHES, THERMOSTATS, INTERLOCKS, ETC. SHALL BE FURNISHED BY MECHANICAL SUBCONTRACTOR. ENSURE THAT THE ELECTRICAL EQUIPMENT MOUNTED NEAR THE MECHANICAL EQUIPMENT DOES NOT BLOCK ACCESS TO SERVICE AREAS OF THE MECHANICAL EQUIPMENT. DO NOT ALLOW ANY EQUIPMENT TO BE INSTALLED ON THE HVAC EQUIPMENT ENCLOSURES. 11. FIRE STOPPING: ALL PENETRATIONS OF FLOORS AND OTHER FIRE-RELATED ASSEMBLIES SHALL BE FIRE AND SMOKE-STOPPED IN STRICT ACCORDANCE WITH THE APPLICABLE CODES. 12. FOUNDATIONS AND SPECIAL SUPPORTS: FURNISH AND INSTALL ALL SPECIAL FOUNDATIONS AND SUPPORTS REQUIRED FOR EQUIPMENT INSTALLED UNDER THIS SECTION, UNLESS THEY ARE A PART OF THE BUILDING STRUCTURE AND ARE SHOWN IN OTHER SECTIONS. 13. CLEANING AND PAINTING: THOROUGHLY CLEAN ALL EQUIPMENT AND REMOVE ALL TRASH, CARTONS, ETC. MAKE ANY NECESSARY CORRECTIONS OR REPAIR/REPLACE ANY DAMAGED MATERIALS OR EQUIPMENT. LEAVE THE ENTIRE SYSTEM IN A THOROUGHLY CLEAN AND ORDERLY MANNER.

AutoCAD SHX Text ANY FINISHED SURFACES THAT HAVE BEEN SCRATCHED OR DISCOLORED SHALL BE TOUCHED-UP OR REPAINTED BREAK TO BREAK WITH PAINT TO MATCH THE ORIGINAL COLOR. TOUCH UP PAINTED SURFACES OR REPAINT THE ENTIRE SURFACE IF TOUCH UP IS UNACCEPTABLE. SEE ARCHITECTURAL PAINTING SPECIFICATIONS. ALL METAL ITEMS SUBJECT TO RUSTING, INSIDE OR EXPOSED TO WEATHER SHALL BE GIVEN ONE COAT OF PROPER TYPE RUST PREVENTATIVE PRIMER AS SOON AS INSTALLED. APPLY TWO FINISH COATS WITH COLOR TO BE SELECTED BY THE ARCHITECT. FOR ALL INTERIOR OR EXTERIOR STRUCTURAL GALVANIZED STEEL, COLD GALVANIZE ALL EXPOSED METAL CUT ENDS, HOLES, WELDS, SCRATCHES, ETC., OR HOT DIP GALVANIZE THE ENTIRE STRUCTURE OR FRAME AFTER FABRICATION AND MOUNTING HOLES ARE CUT. UPON COMPLETION OF THE INSTALLATION, BUT NOT BEFORE, AND BEFORE ACCEPTANCE, THOROUGHLY CLEAN ALL EXPOSED EQUIPMENT, PIPING, DUCTWORK, INSULATION JACKETS, ETC. REMOVING ALL STICKERS, LABELS, MARKINGS, WRITING, IDENTIFICATION, ADHESIVE, SEALER, GLUE, RUST, CORROSION, ETC. FROM THEIR EXTERIOR SURFACES. THE CLEANLINESS AND PAINTING ACCEPTABILITY IS AT THE SOLE DISCRETION OF THE ARCHITECT AND MAY REQUIRE ADDITIONAL CLEANING AND COATS OF PAINT BEFORE ANY SURFACE IS ACCEPTED. 14. SUBMITTALS: SUBMITTAL AND SHOP DRAWINGS: SUBMIT MANUFACTURER'S CERTIFIED DATE RELATIVE TO ALL EQUIPMENT, PIPING, DUCTWORK, CONTROLS, ETC. REQUIRED FOR THE INSTALLATION OF THE HVAC, PLUMBING, AND FIRE PROTECTION SYSTEMS. SUBMIT FOR REVIEW ALL NECESSARY ENGINEERING, PRODUCT AND INSTALLATION DATA, SHOP DRAWINGS, SAMPLES ETC. FOR ALL EQUIPMENT MATERIAL, AND SYSTEMS TO ASCERTAIN COMPLIANCE WITH THE TECHNICAL REQUIREMENTS OF THE CONTRACT DOCUMENTS. SUBMIT ELECTRONIC COPIES OF ALL NECESSARY DATA, CUTS, MANUFACTURER'S SELECTIONS, CATALOGS, BULLETINS, INSTALLATION INSTRUCTIONS, DRAWINGS, DIAGRAMS, CURVES, ETC. CLEARLY INDICATE ON THE SUBMITTED DATA, THE MANUFACTURER'S NAME, PRODUCT NUMBER(S). OPTIONS, EQUIPMENT CAPACITY, DIMENSIONAL DATA, WEIGHTS, AND OTHER APPLICABLE TECHNICAL DATA FOR THE PROJECT. TRADE NAMES, MANUFACTURERS, AND CATALOGUE NUMBERS ARE MENTIONED HEREIN AND ON THE FOLLOWING DRAWINGS SOLELY IN ORDER TO ESTABLISH A STANDARD FOR THE TYPE OF GENERAL DESIGN, AND QUALITY OF PRODUCT REQUIRED. OTHER PRODUCTS SIMILAR IN DESIGN OF EQUIVALENT QUALITY CAPABLE OF FITTING WITHIN THE SPACES ALLOCATED AND COMPLYING WITH THE DRAWINGS AND SPECIFICATION WILL BE CONSIDERED AFTER THE CONTRACT IS LET UNLESS "PRIOR APPROVAL" REQUIREMENTS ARE SET FORTH IN THESE DOCUMENTS. WHERE TWO OR MORE MANUFACTURERS OR MATERIALS ARE NAMED, THE CONTRACTOR MAY SUBMIT ANY OF THOSE NAMES, PROVIDED THEY CONFORM TO THE SPECIFICATIONS AND DESIGN INTENT. CONTRACTORS SHALL INCLUDE WITH THE SUBMITTAL A LIST OF ALL COMPARATIVE FEATURES INDICATING COMPLIANCE WITH THE SPECIFICATIONS. THE ARCHITECT AND/OR ENGINEER MAY REQUIRE THE SUBMISSION OF SAMPLES, PARTICULARLY WHEREVER EQUIPMENT OR APPLIANCES ARE VISIBLE IN FINISHED AREAS SUCH AS CEILINGS, INTERIOR AND EXTERIOR WALLS. THE CONTRACTOR AND SUPPLIER SHALL ARRANGE FOR DEMONSTRATIONS OF INSTALLATION OF ANY OF THERE PRODUCTS AND THEIR ABILITY TO PERFORM AS SPECIFIED, IF REQUIRED. REVIEW OF SUBMITTALS AND SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR FITTING THE EQUIPMENT IN THE SPACE ALLOTTED WITH SPACE FOR ALL CONNECTIONS AND SERVICING AND FOR THE COORDINATION OF THE WORK WITH WORK OF OTHER TRADES. THE CONTRACTOR SHALL REVIEW ALL SUBMITTALS AND SHOP DRAWINGS AND INDICATE BY STAMP OR LETTER THAT HE HAS REVIEWED THEM, BEFORE FORWARDING THEM TO THE ARCHITECT AND/OR ENGINEER. SUBMITTALS AND DRAWINGS WILL BE RETURNED AFTER REVIEW INDICATING WHETHER EXCEPTIONS ARE TAKEN, THE SUBMITTAL RETURNED WITH CORRECTIONS, OR IS COMPLETELY REJECTED. RESUBMISSION OF REVISED SUBMITTALS AND SHOP DRAWINGS, IF REQUIRED, SHALL BE DONE BEFORE INSTALLATION AND CONSTRUCTION IS BEGUN. CORRECTIONS OR COMMENTS MADE ON THE SUBMITTALS AND DRAWINGS DURING THIS REVIEW DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. THIS REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FABRICATION PROCESSES, TECHNIQUES OR CONSTRUCTION, COORDINATING THE WORK WITH THAT OF ALL OTHER TRADES, AND PERFORMING WORK IN A SAFE AND SATISFACTORY MANNER. REVIEW OF THE SUBMITTALS SHALL NOT PERMIT ANY DEVIATION FROM PLANS AND SPECIFICATIONS. SUBMITTALS FOR A SPECIFIC CLASS OF PRODUCTS, SYSTEMS, INSTALLATIONS PROCEDURES, SHOP DRAWINGS, ETC. WILL BE REVIEWED BY THE ENGINEER ONE TIME AND ITS RE-SUBMITTAL ONE TIME, IF NECESSARY, AS ABOVE, AT NO COST TO THE CONTRACTOR. THE CONTRACTOR WILL BEAR THE FULL COST FOR ALL SUBSEQUENT RE-SUBMITTAL REVIEWS AT THE ENGINEER'S STANDARD HOURLY RATES. PAYMENT WILL BE REQUIRED AT COMPLETION OF RESPECTIVE REVIEW. REQUIRED SHOP DRAWINGS: SUBMIT THE FOLLOWING SHOP DRAWINGS BEFORE ANY MECHANICAL DUCTWORK, PIPING, EQUIPMENT, ETC. IS FABRICATED AND INSTALLED. SUBMIT THESE SHOP DRAWINGS IN 1/4 INCH PER FOOT MINIMUM SCALE WITH NECESSARY PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ISOMETRICS. SUBMIT ELECTRONIC AND ONE (1) CD-ROM WITH ALL THESE DRAWINGS IN AUTO CAD DRAWING DWG FILES, LATEST AUTOCAD FORMAT. SOON AFTER AWARD OF THE CONTRACT, DETERMINE WHERE THERE MAY BE INSTALLATION, SPACE CONCERNS, AND/OR WHERE OTHER CONFLICTS MAY OCCUR. SUBMIT COORDINATION DRAWINGS, RELATING TO THESE CONFLICTS WITH THE MECHANICAL EQUIPMENT, DUCT, PIPING, ELECTRICAL, STRUCTURAL AND ARCHITECTURAL SYSTEMS ETC., SHOWING CLEARANCES AND RELATIONSHIP TO STRUCTURAL MEMBERS, PIPING, LIGHTS, CONDUITS, ELECTRICAL EQUIPMENT, AND BUILDING COMPONENTS. IN PREPARING THESE SHOP DRAWINGS, ESTABLISH LINES AND LEVELS FOR ALL DIVISIONS OF THE WORK IN THE AFFECTED AREA. IMMEDIATELY CALL TO THE ATTENTION OF THE ARCHITECT ANY INTERFERENCE OR CONFLICT FOR CLARIFICATION IN WRITING. SUBMIT SHOP DRAWINGS FOR ALL DUCT WORK. SUBMIT LAYOUT DRAWINGS OF EACH MECHANICAL SYSTEM SHOWING THE LOCATION, ARRANGEMENT, ETC. OF ALL EQUIPMENT, ALL TRADES ETC. TO BE INSTALLED RELATED TO THE RESPECTIVE SYSTEM. MAINTAIN DAILY UPDATED DRAWINGS SHOWING DEVIATIONS FROM CONSTRUCTION DOCUMENTS. AT THE END OF THE PROJECT, PROFESSIONALLY PREPARE AS-BUILT DRAWINGS AND SUBMIT THREE COPIES, ONE REPRODUCIBLE. 15. AS-BUILT DRAWINGS: MAINTAIN DAILY UPDATED DRAWINGS SHOWING DEVIATIONS FROM CONSTRUCTION DOCUMENTS. AT THE END OF THE PROJECT, PROFESSIONALLY PREPARE AS-BUILT DRAWINGS AND SUBMIT THREE COPIES, ONE REPRODUCIBLE. 16. OPERATION AND MAINTENANCE MANUALS: UPON COMPLETION OF THE PROJECT, SUBMIT THREE COPIES OF ALL OPERATION AND MAINTENANCE MANUALS, WARRANTIES, SPARE PARTS LIST, AS BUILT DRAWINGS, TEST AND BALANCE REPORTS, AND LETTER OF GUARANTEE ALL BOUND IN THREE RING BINDERS, CLEARLY SHOWING WHICH EQUIPMENT WAS SUPPLIED TO THE JOB. 17. PROJECT COMPLETION: BEFORE STARTING AND TESTING ANY SYSTEM, HVAC, OR PLUMBING, TO PREVENT INADVERTENT OPERATION OF THE MECHANICAL EQUIPMENT BEFORE THE MANUFACTURERS INSPECTION AND TESTING THE CONTRACTOR SHALL: VERIFY THAT ALL ELECTRICAL POWER IS OFF TO ALL MECHANICAL EQUIPMENT, INCLUDING THE AHU'S, ACCU'S, BOOSTER PUMP, FIRE PUMPS, ETC. LOCK OUT EACH SYSTEM USING SETON MODEL NUMBER 70329; "DO NOT OPERATE" LOCK ON LOCKOUT TAGS, OR EQUIVALENT. INSTALL LOCKOUT TAGS AT EACH PIECE OF EQUIPMENT, ELECTRICAL DISCONNECTS, STARTERS, SWITCHES, ETC. REMOVE THESE TAGS ONLY WHEN THE MANUFACTURER APPROVES OF THE EQUIPMENT INSTALLATION IN WRITING. EACH MANUFACTURER OR THEIR REPRESENTATIVE SHALL INSPECT THEIR EQUIPMENT FOR COMPLIANCE TO THEIR INSTALLATION REQUIREMENTS AND RECOMMENDATIONS.

AutoCAD SHX Text IN ADDITION, THE COMPRESSOR MANUFACTURER SHALL INSPECT EACH REFRIGERANT PIPING INSTALLATION FOR THE ADHERENCE TO THE APPROVED REFRIGERANT PIPING DIAGRAMS, ROUTING. EACH MANUFACTURER SHALL PREPARE A PUNCH LIST OF ALL DEFICIENCIES, IN WRITING WITH COPIES TO THE ARCHITECT AND CONTRACTOR. EACH MANUFACTURER SHALL RE-INSPECT THE THE EQUIPMENT AFTER THE CONTRACTOR HAS CORRECTED ALL DEFICIENCIES. WHEN THE MANUFACTURER HAS GIVEN THEIR WRITTEN APPROVAL WITH COPIES TO THE ARCHITECT AND CONTRACTOR, THE CONTRACTOR MAY REMOVE THE LOCKOUT TAGS, SAFELY START, AND TEST THE EQUIPMENT, AS REQUIRED HEREIN. CONTRACTOR SHALL PROVIDE FOR ALL NECESSARY DRILLING OF WALL STUDS, CEILING JOISTS, PLATES, FINISHES, ETC. TO ACCOMMODATE ROUTING AND INSTALLATION OF ALL PIPING, DUCT, ETC. DIVISION 23 SPECIFICATIONS: HVAC EQUIPMENT, METHODS AND MATERIALS 18. DUCTWORK GENERAL: DUCT SIZES SHOWN ON THE DRAWINGS ARE INSIDE DIMENSIONS AND DO NOT TAKE INTO ACCOUNT LINING THICKNESS, DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH GAUGES, CONSTRUCTION DETAILS AND INSTALLATION ACCORDING TO N.F.P.A. STANDARD 90A ASHRAE, AND SMACNA DUCT CONSTRUCTION MANUALS AND REQUIREMENTS. PROVIDE FLEXIBLE CONNECTIONS AT AIR HANDLING UNITS AND FANS. PROVIDE SINGLE THICKNESS TURNING VANES IN ELBOWS. ALL DUCTS 18" AND OVER SHALL BE CROSS-BROKEN PAINT DUCTS, SLEEVES, PLENUMS, ETC. INTERIORS VISIBLE THROUGH AIR DEVICES WITH A MINIMUM OF ONE COAT OF PROPER TYPE RUST PREVENTATIVE PRIMER, SUITABLE FOR GALVANIZED STEEL, AND TWO FINISH COATS OF FLAT BLACK PAINT. 19. DUCT CONSTRUCTION MATERIALS: RECTANGULAR SUPPLY, RETURN, OUTSIDE AIR, AND EXHAUST: LINED GALVANIZED SHEET METAL ROUND DUCT AND RUN-OUTS: EXTERNALLY INSULATED GALVANIZED SHEET METAL DUCTS WITH SPIRAL LOCK SEAMS. FLEXIBLE DUCT: PRE-INSULATED FLEXIBLE DUCT. NO FLEXIBLE DUCT RUNS LONGER THAN 5 FEET. PROVIDE DRYER VENT PIPING INSTALLED AS REQUIRED BY THE MANUFACTURER AND PER CODE USING 4 INCH ROUND GALVANIZED STEEL, SEALED AND SUPPORTED. THE USE OF FLEXIBLE DRYER VENT PIPE IS PROHIBITED. 20. FABRICATION, ERECTION AND SUPPORT. ALL DUCTWORK SHALL BE FABRICATED, ERECTED AND SUPPORTED IN STRICT ACCORDANCE WITH THE LATEST EDITIONS OF SMACNA AND ASHRAE REQUIREMENTS. 21. ACOUSTIC LINED DUCTWORK: ACOUSTICALLY AND THERMALLY LINE 10' OF RECTANGULAR SUPPLY RETURN, OUTSIDE AIR AND EXHAUST DUCT AND PLENUMS WITH 1-1/2" THICK, 1-1/2" PCF FIBERGLASS DUCT LINER (R-6 MIN.) APPLIED PER THE MANUFACTURER'S AND NAIMA REQUIREMENTS. DUCT LINER SHALL MEET OR EXCEED ASHRAE'S I.A.Q. STANDARD 62 AND IEEC. USE WELDED STICK CLIPS, IN LIEU OF ADHESIVE TYPE FASTENERS AND FULL COVERAGE ADHESIVE. PROVIDE EDGE NOSINGS WHERE REQUIRED. COAT ALL EXPOSED FIBERGLASS WITH HARDCAST "LAG-GRIP 671". 22. JOINT SEALINGS: SEAL ALL DUCT JOINTS AND SEAMS (LONGITUDINAL AND TRANSVERSE) WITH HIGH PRESSURE DUCT SEALER, HARDCAST "IRON-GRIP 601" OR APPROVED EQUIVALENT. REINFORCED FOIL BACKED TAPES, CLOTH OR PLASTIC BACKED TAPES (DUCT TAPE) ARE NOT ACCEPTAVLE. 23.FLEXIBLE AIR DUCT: DUCT SHALL BE UL LISTED UL-181, CLASS 1 AIR DUCT MATERIAL AND SHALL COMPLY WITH N.F.P.A. 90A AND 90B AND ALL LOCAL REQUIREMENTS, DUCT SHALL HAVE AN OPERATING AIR PRESSURE OF 6 INCHES WG POSITIVE AND 4 INCHES WG NEGATIVE, ACOUSTICAL DOUBLE LAMINATED INNER FABRIC BONDED TO STEEL HELIX WIRE. OUTER JACKET FIRE RETARDANT REINFORCED ALUMINUM MYLAR WITH FIBERGLASS INSULATION. FLEXMASTER TYPE "8M" ACOUSTICAL INSULATED OR EQUIVALENT. MAKE ALL FLEXIBLE DUCT CONNECTIONS TO HARD DUCT USING STAINLESS STEEL SCREW CLAMPING BANDS AND SEALED AIR TIGHT WITH HIGH PRESSURE DUCT SEALER. PLASTIC BANDS ARE NOT ACCEPTABLE. 24. AIR DISTRIBUTION DEVICES: COORDINATE THE EXACT LOCATIONS OF ALL AIR DEVICE NEEDS WITH THE ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATION. COORDINATE THE EXACT LOCATION OF EACH OUTLET WITH THE ARCHITECT WITH REGARD TO CEILING AND WALL SPACING, CENTERING ALONG SOFFITS, WALLS, ETC. FURNISH AND INSTALL WHERE SHOWN ON THE DRAWINGS ALL DIFFUSERS, GRILLES, AND REGISTERS OF THE SIZE, TYPE, AND CAPACITY AS INDICATED ON THE AIR DEVICE SCHEDULE. ELBOWS: 25. TURNING VANES AND SMOOTH RADIUS ELBOW (WITHOUT VANES): AT ALL DUCT TURNS OF 45 DEGREES OR MORE, PROVIDE SINGLE THICKNESS TURNING VANES PER SMACNA REQUIREMENTS. ALTERNATELY, USE SMOOTH RADIUS ELBOW (R/W = 1.5). 26. BRANCH TAKEOFF FITTINGS: AT ALL MAIN BRANCH DUCT TAPS, TAKEOFFS, OR RUN-OUTS PROVIDE 45 DEGREE ENTRANCE TAPS, AS DETAILED BY SMACNA STANDARDS. 27. DUCT MOUNTED ACCESS PANELS: INSTALL ACCESS PANELS AS FOLLOWS: AT INLET OF EACH DUCT MOUNTED FIRE AND MOTORIZED DAMPER. FOR DUCT MOUNTED CONTROLS. AS REQUIRED AND DIRECTED BY THE TEST AND BALANCE CONTRACTOR. WHERE REQUIRED FOR DUCT INSPECTION, MAINTENANCE, AND CLEANING. ACCESS PANELS SHALL BE 18 INCHES X 18 INCHES OR LARGEST DUCT WILL ALLOW. NORMALLY CENTER THE ACCESS PANEL ON THE BOTTOM OF THE DUCT AS CLOSE AS POSSIBLE TO THE DUCT MOUNTED DEVICE. ACCESS PANELS MAY BE INSTALLED ON THE SIDE OF THE DUCT, WHERE NECESSARY. ACCESS PANELS SHALL BE DOUBLE WALL INSULATED HINGED WITH NEOPRENE GASKETS AND CAM LOCKS ON EACH UNHINGED SIDE. WHERE REQUIRED BECAUSE OF PANEL OPENING CLEARANCE, SUBSTITUTE UNHINGED ACCESS PANELS WITH CAM LOCKS ON EACH SIDE AND CAPTIVE CHAIN. ACCESS PANELS SHALL BE FLEXMASTER "TBSM-TAB DOOR" GREENHECK MODEL "HAD-10" OR EQUIVALENT. INSULATION: 28. GENERAL THIS SECTION APPLIES TO ALL MECHANICAL WORK. ALL INSULATION SHALL BE IN STRICT ACCORDANCE WITH ASHRAE STANDARDS AND ALL LOCAL AND STATE ENERGY CODES. THE INSULATION WORK SHALL BE PERFORMED BY A FIRM REGULARLY ENGAGED IN THIS TYPE OF WORK USING MECHANICS SKILLED IN THE TRADE.

INSTALL ALL MATERIALS AS RECOMMENDED BY THE MANUFACTURER FOR THE SERVICE INTENDED. ALL INSULATION MATERIAL, INCLUDING SEALER MATERIAL, ADHESIVES, COVERING MATERIAL, FINISH, ETC. SHALL HAVE A U.L. LISTED FLAME SPREAD RATING NOT OVER 24 WITHOUT EVIDENCE OF CONTINUED PROGRESSIVE COMBUSTION AND WITH A SMOKE DEVELOPED RATING NOT HIGHER THAN 50. ALL COATINGS AND COVERINGS FOR HOT SERVICE SHALL BE BREATHER TYPE AND VAPOR BARRIER TYPE FOR COLD SERVICE. 29. EQUIPMENT: CAPACITY, PERFORMANCE AND CHARACTERISTICS OF EQUIPMENT SHALL BE AS INDICATED ON THE DRAWINGS AND AS SPECIFIED OR IMPLIED HEREIN. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY INCREASED COST TO HIMSELF OR OTHERS FOR EQUIPMENT WHICH DEVIATES FROM THAT SCHEDULED OR IMPLIED HEREIN. REGARDLESS OF COST AFFECT, THE ARCHITECT MUST APPROVE ANY DEVIATION FROM THE DRAWINGS AND THE SPECIFICATION. 30. MOTORS AND STARTERS: ALL ELECTRIC MOTORS SHALL BE HIGH EFFICIENCY TYPE WITH MAXIMUM OF 1750 RPM WITH OPEN DRIP PROOF OR TEFC ENCLOSURES, UNLESS OTHERWISE NOTED. MOTORS LOCATED ON AIR HANDLING UNITS SHALL BE MOUNTED IN RUBBER SUPPORTS OR THE FAN SHALL BE INDEPENDENTLY SUPPORTED ON SPRING ISOLATORS. MOTORS LOCATED IN THE CONDITIONED SPACE SHALL BE SELECTED FOR QUIET OPERATION AND SHALL NOT PRODUCE AN OBJECTIONABLE “MOTOR NOISE” IN THE SPACE. MOTOR NOISE” IN THE SPACE. IN THE SPACE. ELECTRICAL CHARACTERISTIC SHALL BE VERIFIED FROM THE ELECTRICAL DRAWINGS, PRIOR TO BIDDING, AND VERIFIED ON THE JOB WITH THE ELECTRICAL SUB-CONTRACTOR. IF A CONFLICT ARISES, THE ELECTRICAL DRAWINGS SHALL BE THE AUTHORITY. PROVIDE MOTOR STARTS AND PROPER HEATER ELEMENTS SIZED IN ACCORDANCE WITH NFPA 70. STARTERS SHALL BE SQUARE-D OR EQUIVALENT WITH OVERLOAD TRIP ELEMENT IN EACH PHASE. LARGER MOTORS AND THEIR STARTS SHALL MEET THE REQUIREMENTS OF THE UTILITY COMPANY AS TO INRUSH ALLOWABLE AND THE TYPE OF STARTING PERMITTED. SHOULD ANY MECHANICAL EQUIPMENT REQUIRE EXTRA WORK BY OTHER TRADES, FOR PROPER INSTALLATION, THIS CONTRACTOR SHALL BEAR ALL COSTS, SUCH AS INCREASED ELECTRICAL, STRUCTURAL, ROOFING, ETC. SYSTEMS TEST AND BALANCE: 31. GENERAL REQUIREMENTS: THE REQUIRED TEST AND BALANCE OF THE HVAC SYSTEM SHALL BE PERFORMED BY AN APPROVED INDEPENDENT TESTING AGENCY AS SPECIFIED BELOW AND IN ACCORDANCE WITH THE 2015 IECC C408.2. 32. AGENCY QUALIFICATIONS: TEST & BALANCE AGENCY (TBA) SHALL BE PERFORMED BY AN INDEPENDENT AGENCY ENGAGED SOLELY IN TEST AND BALANCE WORK. AGENCY SHALL BE MEMBER OF THE ASSOCIATED AIR BALANCE COUNCIL (AABC) AND NATIONAL ENVIRONMENTAL BALANCING BUREAU, (NEBB). SUBMIT A WRITTEN REPORT WITHIN 30 DAYS OF COMMENCING WORK, WITH ANY RECOMMENDED CHANGES TO INSURE BALANCING CAPABILITY. SUBMIT A DETAILED TEST PLAN TO THE ARCHITECT ILLUSTRATING ALL FORMATS, DRAWINGS, AND TEST PROCEDURE TO BE USED FOR TESTING THE COMPLETED SYSTEM. THE APPROVED PLAN WILL BE USED FOR TESTING THE SYSTEMS. PROCEDURES SHALL INCLUDE REQUIREMENTS LISTED IN AABC/NEBB STANDARDS, LATEST EDITION AND ANY SPECIAL REQUIREMENTS FOR THIS PROJECT. MAKE PROJECT VISITS AS REQUIRED DURING CONSTRUCTION PERIOD INSPECTING FOR PROPER INSTALLATION OF THE SYSTEM AND RELATED BALANCING DEVICES. PROJECT VISIT REPORTS SHALL BE MADE TO THE ARCHITECT IN WRITING. 33. CONTRACTORS REQUIREMENTS PRIOR TO TEST & BALANCE: THE CONTRACTOR SHALL PERFORM ALL REQUIRED PRELIMINARY TESTS AND OTHER PREPARATORY WORK, INCLUDING BUT NOT LIMITED TO: MAKE SURE ALL FANS ARE OPERATING, CHECK ROTATION, RPM, AND AMPS. CHECK ALL DAMPERS FOR OPERATION. PUT ALL HVAC EQUIPMENT IN FULL OPERATION INCLUDING AIR UNITS, ACCU'S AND FANS. MAKE SURE ALL HVAC CONTROLS ARE INSTALLED AND FULLY OPERATIONAL. CLEAN/REPLACE FILTERS JUST PRIOR TO TESTING. PROVIDE ALL BALANCING DEVISE AND DRIVE CHANGES THAT ARE DEEMED NECESSARY BY T&B AGENCY FOR BALANCE AT NO ADDITIONAL COST TO THE OWNER. 34. TEST AND BALANCE: TEST & BALANCE AGENCY SHALL BALANCE ALL AIR SYSTEMS FOR OPERATION WITHIN DESIGN CRITERIA. PRIME MOVERS SHALL BE WITHIN 5% OF DESIGN AND TERMINALS WITHIN 10% OF DESIGN. AIR SYSTEMS SHALL BE BALANCED AS DESCRIBED HEREIN. 35. TEST REPORT: THE TBA SHALL PREPARE FIVE (5) COPIES OF A FINAL COMPREHENSIVE TEST REPORT IN THE FOLLOWING FORMAT. REPORT SHALL BE BOUND 8-1/2” X 11” WITH SUBSTANTIAL COVERS USING APPROVED FORMS, TYPED OR X 11” WITH SUBSTANTIAL COVERS USING APPROVED FORMS, TYPED OR WITH SUBSTANTIAL COVERS USING APPROVED FORMS, TYPED OR COMPUTER GENERATED REPORTS ARE ACCEPTABLE. REPORT SHALL BE INDEXED. TABLE OF CONTENTS SHALL LIST ALL REPORTS. ALL AIR OUTLETS SHALL BE LOCATED ON CODED DRAWINGS PREPARED BY THE T&B AGENCY. AIR OUTLETS FORMS SHALL BE PREPARED AND CORRELATED TO THE CODED DRAWINGS. TEST SUMMARY SHALL DESCRIBE FINAL TEST PROCEDURES AND SPECIAL CONDITIONS DURING TESTS (SUCH AS THERMOSTAT OUTSIDE/RETURN AIR RELATIONSHIP, AND DUCT STATIC PRESSURE.) DESCRIBE OTHER DATA THAT MAY ASSIST OPERATING PERSONNEL IN THE CONTINUING OPERATION OF THE SYSTEM. T&B CONTRACTOR SHALL TAKE AND RECORD ALL NECESSARY READINGS AT THE FINAL BALANCE POINTS, SUCH AS BUT NOT LIMITED TO: AIR QUANTITIES, PRESSURES, SET POINTS, ENTERING AND LEAVING COIL TEMPERATURES, SPACE INDOOR AND OUTSIDE WET AND DRY BULB TEMPERATURES, OUTDOOR WEATHER CONDITIONS, ELECTRICAL READINGS OF ALL NEW AND EXISTING MOTORS, COMPRESSORS, ETC. TEST REPORT SHALL CONTAIN TBA CERTIFICATION OF TEST DATA AND SYSTEM CONDITIONS. SUBMIT THE TEST REPORTS FOR REVIEW BEFORE SUBSTANTIAL COMPLETION.

EXHAUST FAN SCHEDULE

ITEM

MANUFACTUR

ER/MODEL

NO.

LOCATION/

SERVICE CFM ESP FAN

RPM

ELECTRIC DATA

NOTES

HP VOLT PH HZ MCA

PANASONIC/

FV-0511VK2 BATHROOMS 50 < 0.30 1113 8.3 W 115 1 60 0.2 ALL APPLY

PANASONIC/

FV-0511VK2 CRAWL SPACE 100 < 0.30 1113 8.3 W 115 1 60 0.2 ALL APPLY

CONDENSEOR SCHEDULE*

ITEM MANUFACTURER/

MODEL LOCATION

CO

OL

IN

G

CA

PA

CI

TY

(M

BH

HE

AT

IN

G

CA

PA

CI

TY

(M

BH

MI

NI

MU

M

EF

FIC

IE

NC

Y (S

EE

R)

REFRIGERANT RLA LRA MCA MAX

FUSE/BREAK

VOLT/

PHASE

WEIGH

T (LBS) OVERALL DIMENSIONS NOTES

CARRIER

27TPA836A003 SEE PLANS 36.0 36.0 18.0 R-454B 18.5 90.0 25.7 40 208/1 260 35"L X 35"W X 38-7/8"H ALL APPLY

CARRIER

27TPA848A003 SEE PLANS 48.0 48.0 18.0 R-454B 23.00 138.0 31.4 50 208/1 309 35"L X 35"W X 45-11/16"H ALL APPLY

FAN COIL SCHEDULE*

ITEM MANUFACTURER/

MODEL LOCATION CAPACITY

(MBH)

CFM

(MAX) REFRIGERANT

FAN AUXILIARY HEAT STRIP

FLA MCA

MAX

FUSE/

BREAK

VOLT/

PHASE SIZE VOLT/

PHASE

HEATER

AMPS

MIN

AMP

MAX

FUSE/

BREAK

WEIGHT

(LBS) OVERALL DIMENSIONS NOTES

CARRIER

FJ5ANXB36L10 SEE PLANS 36 1050 R-454B 4.2 5.3 15 208/1 10kW 208/240

1Ø 35.6/ 39.4

52.1/

56.9 70 148 17-5/8"H X 22-1/16"W X

49-5/8"L ALL APPLY

CARRIER

FJ5ANXC48L10 SEE PLANS 48 1400 R-454B 6.1 7.6 15 208/1 10kW 208/240 1Ø

35.6/ 39.4

52.1/

56.9 70 182 21-1/8"H X 22-1/16"W X

53-7/16"L ALL APPLY

GRILLE, DIFFUSER, AND LOUVER SCHEDULE

SYMBOL USE PATTERN ACCESSORIES FINISH MODEL

NUMBER REMARKS

S1 CEILING SUPPLY

DIFFUSER EXISTING - TO REMAIN IN SAME LOCATION OR RELOCATED. SEE PLAN KEYNOTES ON SHEET M1.0

S2 CEILING SUPPLY

DIFFUSER FIXED -- BY ARCH. TITUS-TMS 12"X12" FACE

NECKSIZE VARIES (SEE DRAWINGS)

R1

CEILING RETURN

AIR FILTER

GRILL

FIXED -- BY ARCH. TITUS-350FLF1 SIZE VARIES (SEE DRAWINGS)

W

2 CEILING DIFFUSER DETAIL

NO SCALE

SPIN IN FITTING WITH

BALANCING DAMPER.

SEE SPEC.

SUPPORT TO STRUCTURE

SHEET METAL SUPPLY DUCT.

SEE PLANS FOR SIZE

RADIUS + 2D MIN.

FLEXIBLE DUCT

ROUND NECK SAME

AS DUCT SIZE

CEILING DIFFUSER

WITH SQUARE TO

ROUND NECK

ADAPTOR

LAY-IN

SURFACE MOUNT

LINE WITH 1" OF

ACOUSTICAL INSULATION

SEE PLAN FOR DUCT SIZE

SHEET ROCK CEILING

SURFACE MOUNTLAY-IN

TEE BAR CEILING

O.B.D.

SEE PLAN FOR

NECK SIZE AND

LOCATION

1 DIFFUSER MOUNTING DETAIL

NO SCALE

1.

W

SECURE FLEXIBLE

DUCT W/ SHEETMETAL

SCREWS & DRAWBANS

FINISH W/ NASHUA #557

UL 181B TAPE (TYP.0

MAX 5'-0" LONG

FLEXIBLE DUCT (TYP.)

SQUARE TO ROUND

TRANSITION

DRAWBAND

D W

1.5 D

DIFFUSER / REGISTER

ACCESSIBLE CEILING, PROVIDE PLASTER

FRAME FOR GYP. BOARD CEILINGS (TYP.)

2" CONCRETE

ANCHOR BOLT

CONCRETE

FLOOR

UNISTRUT P1204

2"THEARDED ROD

w/ HHXN 12" NUTS

HHXN 12" NUTS ON

UNIT MOUNTING TAB

INSTALL UNISTRUT

P1000 TRANSVERSE

BRACE TO CONCRETE

FLOOR

6 CEILING MOUNTED UNIT SUPPORT

NO SCALE

3 VENT DETAIL

NO SCALE

NOTE: INSTALL AS PER MANUFACTURER'S INSTRUCTIONS

URETHANE FOAM SEALANT AROUND

DUCT/PIPE PENETRATION AT INSULATION

SHEATHING

METAL CAP

FLASHING

CAULK

AROUND

VENT CAP

EDGE

VENT DUCT

OUTSIDE WALL

SPECIFIED

VENT CAP

BIRD SCREEN

BACK DRAFT DAMPER

4 INLET DETAIL

NO SCALE

NOTE: INSTALL AS PER MANUFACTURER'S INSTRUCTIONS

URETHANE FOAM SEALANT AROUND

DUCT/PIPE PENETRATION AT INSULATION

SHEATHING

CAULK

AROUND

VENT CAP

EDGE

VENT DUCT

OUTSIDE WALL

SPECIFIED

GRILL

MOUNTING BRACKET

BACK DRAFT DAMPER

5 DUCT LINER DETAIL

NO SCALE

8 BRANCH DUCT TAKE-OFF & DAMPER DETAIL

NO SCALE

7 FLEX DUCT/SPIN-IN FITTING

NO SCALE

9 SPLIT SYSTEM FANCOIL DETAIL

NO SCALE

M0.3

NTS

GA

M

EC

H

AN

IC

AL

S C

H

ED

U

LE

S

D

ET

AI

LS

SHEET:

IRON ROCK

GROUP

Building on Solid Foundations

460 E. 300 SOUTH

KANAB, UTAH 84741

435-644-2031 www.ironrockeng.com

R

EV

SCALE:

DRAWN BY:

IN

IT

IA

L

SU

B

M

IT

TA

L:

D A

TE

D

ES

C R

IP

TI

O N

R

EV

IS

IO

N

9/

/2

© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,

DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL

PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS

AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE

COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS

AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION, DISTRIBUTION,

PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN WHOLE OR IN

PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM IRON ROCK

GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS PROHIBITED.

W . 3

N

. K

AN

AB

, U

TA

H

KA

N

E C

O U

N

TY

A

SS

ES

SO

R S

O

FF

IC

E

R

EN

O

VA

TI

O

N 9/

8/

THOMAS W.

AVANT

#5561917

RE

E

NI

G

NE

LANOISSEFORP

DERETSI G E R

STATE OF U TAH

Thomas Avant

9/24/2026

AutoCAD SHX Text

EF

AutoCAD SHX Text

1. PROVIDE WITH BACKDRAFT DAMPER AND BIRDSCREEN PROVIDE WITH BACKDRAFT DAMPER AND BIRDSCREEN 2. PROVIDE FACTORY MOUNTED DISCONNECT SWITCH PROVIDE FACTORY MOUNTED DISCONNECT SWITCH 3. PROVIDE EXHAUST AIR DUCT THOROUGH WALL/ROOF WITH A WALLCAP/ROOFCAP AND BACKDRAFT DAMPER PROVIDE EXHAUST AIR DUCT THOROUGH WALL/ROOF WITH A WALLCAP/ROOFCAP AND BACKDRAFT DAMPER 4. SEE PLANS FOR QUANTITIES SEE PLANS FOR QUANTITIES 5. CONSTRUCT PER 2021 IBC SECTIONS 717.6.1 WITH #26 GAUGE THICKNESS CONSTRUCT PER 2021 IBC SECTIONS 717.6.1 WITH #26 GAUGE THICKNESS 6. CONNECTED WITH LIGHT SWITCH. SET TO OPERATE CONTINUOUSLY WHILE OCCUPIEDCONNECTED WITH LIGHT SWITCH. SET TO OPERATE CONTINUOUSLY WHILE OCCUPIED

AutoCAD SHX Text

AutoCAD SHX Text

EF

AutoCAD SHX Text

AutoCAD SHX Text

CU

AutoCAD SHX Text 1.X

AutoCAD SHX Text

CU

AutoCAD SHX Text

1. CYCLE PROTECTOR CYCLE PROTECTOR 2. TIME DELAY RELAY TIME DELAY RELAY 3. MOTOR FAN BALL BEARING MOTOR FAN BALL BEARING 4. CRANKCASE HEATER CRANKCASE HEATER 5. LOW AMBIENT KIT LOW AMBIENT KIT 6. PROVIDE MATCHING COOLING COIL TO BE PIPED AT AIR HANDLER LOCATION. PROVIDE MATCHING COOLING COIL TO BE PIPED AT AIR HANDLER LOCATION. 7. PROVIDE PRE-INSULATED REFRIGERANT LINE SETS. EXTEND TO ROOF TOP CONDENSING PROVIDE PRE-INSULATED REFRIGERANT LINE SETS. EXTEND TO ROOF TOP CONDENSING UNITS THROUGH ROOF CHASES. 8. INSTALL PER MANUFACTURER'S INSTRUCTIONS INSTALL PER MANUFACTURER'S INSTRUCTIONS 9. LIQUID LINE SOLENOID VALVE LIQUID LINE SOLENOID VALVE 10. WINTER START CONTROLWINTER START CONTROL

AutoCAD SHX Text

*OR APPROVED EQUIVALENT

AutoCAD SHX Text

FC

AutoCAD SHX Text

1. CYCLE PROTECTOR CYCLE PROTECTOR 2. TIME DELAY RELAY TIME DELAY RELAY 3. MOTOR FAN BALL BEARING MOTOR FAN BALL BEARING 4. CRANKCASE HEATER CRANKCASE HEATER 5. LOW AMBIENT KIT LOW AMBIENT KIT 6. PROVIDE MATCHING COOLING COIL TO BE PIPED AT AIR HANDLER LOCATION. PROVIDE MATCHING COOLING COIL TO BE PIPED AT AIR HANDLER LOCATION. 7. PROVIDE PRE-INSULATED REFRIGERANT LINE SETS. EXTEND TO ROOF TOP CONDENSING PROVIDE PRE-INSULATED REFRIGERANT LINE SETS. EXTEND TO ROOF TOP CONDENSING UNITS THROUGH ROOF CHASES. 8. INSTALL PER MANUFACTURER'S INSTRUCTIONS INSTALL PER MANUFACTURER'S INSTRUCTIONS 9. LIQUID LINE SOLENOID VALVE LIQUID LINE SOLENOID VALVE 10. WINTER START CONTROLWINTER START CONTROL

AutoCAD SHX Text

*OR APPROVED EQUIVALENT

AutoCAD SHX Text

X=SYSTEM

AutoCAD SHX Text 2.X

AutoCAD SHX Text

X=SYSTEM

AutoCAD SHX Text 1.X

AutoCAD SHX Text

X=SYSTEM

AutoCAD SHX Text

FC

AutoCAD SHX Text 2.X

AutoCAD SHX Text

X=SYSTEM

AutoCAD SHX Text

*OR APPROVED EQUIVALENT: TITUS, KRUEGER, METAL-AIRE, NAILOR

AutoCAD SHX Text *FOR ALL LINEAR SLOT DIFFUSER CONTRACTOR TO BUILD INSULATED SHEET METAL PLENUM BOX 2" GREATER IN HEIGHT THAN CONNECTING DUCT X L X W OF DIFFUSER.

** PROVIDE A MOTORIZED DAMPER INTERLOCKED WITH ASSOCIATED EQUIPMENT.

131 SF

USU OFFICE

101 SF

USU OFFICE

103 SF

USU OFFICE

68 SF

STORAGE

101 SF

FLEX OFFICE

101 SF

FLEX OFFICE/DMV

50 SF

UNISEX

50 SF

UNISEX

30 SF

ELECTRICAL

54 SF

ADA

233 SF

DMV OFFICE

177 SF

DMV LOBBY

217 SF

CONFERENCE ROOM

117 SF

ASSESSOR OFFICE

123 SF

ASSESSOR OFFICE

174 SF

RYAN'S OFFICE

99 SF

ASSESSOR OFFICE

99 SF

ASSESSOR OFFICE

130 SF

ASSESSOR OFFICE

112 SF

USU OFFICE

112 SF

ASSESSOR OFFICE

392 SF

CONFERENCE ROOM

165 SF

PRODUCTION

BREAK ROOM

178 SF

RECORDS

36 SF

IT

38 SF

JANITOR

4"

4"

4"

EF

EF

EF

EF

4"

2 2

2 2

8" 10" 12" 18" 14" 12"

8"

8" 8" 8" 10" 10"

14"

8"

8"

10"12"12"12"10"10"

10" 8" 8" 10"

8" 8"

18" 14"

20"

20"

18"

16"

8"

8"

8"

8" 14"

10"

8"

8" 10"

18"

16" 6"

16"

8"

14" 8" 8"

8" 8"

8" 10"

FC

2.1

FC

1.1

FC

2.3

FC

2.2

R1

20"X40" R1

20"X40"

R1

20"X40"

R2

20"X20"

S1

S1

S1

S1

S1 247 S1

S1

S2

S1

S1

S1

S1

S1

S1

S1

S1

S1 173 S1

133 S1

S1

S1

S1

S2

20"

S1

S1

S1

S1

S1

S1

CU

1.1

CU

2.1

CU

2.2

CU

2.3

M1.0

1/4" = 1'

GA

M

EC

H

AN

IC

AL

P

LA

N

SHEET:

IRON ROCK

GROUP

Building on Solid Foundations

460 E. 300 SOUTH

KANAB, UTAH 84741

435-644-2031 www.ironrockeng.com

R

EV

SCALE:

DRAWN BY:

IN

IT

IA

L

SU

B

M

IT

TA

L:

D A

TE

D

ES

C R

IP

TI

O N

R

EV

IS

IO

N

9/

/2

© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,

DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL

PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS

AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE

COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS

AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION, DISTRIBUTION,

PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN WHOLE OR IN

PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM IRON ROCK

GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS PROHIBITED.

W . 3

N

. K

AN

AB

, U

TA

H

KA

N

E C

O U

N

TY

A

SS

ES

SO

R S

O

FF

IC

E

R

EN

O

VA

TI

O

N 9/

8/

THOMAS W.

AVANT

#5561917

RE

E

NI

G

NE

LANOISSEFORP

DERETSI G E R

STATE OF U TAH

Thomas Avant

9/24/2026

AutoCAD SHX Text

4" EXHAUST DUCT FROM NEW EXHAUST FAN IN CRAWL SPACE TO EXTERIOR.

AutoCAD SHX Text

MECHANICAL PLAN KEYNOTE

AutoCAD SHX Text

AutoCAD SHX Text EXISTING HVAC SUPPLY GRILL. TO REMAIN IN EXISTING LOCATION. CONNECT TO NEW SYSTEM AS SHOWN ON PLANS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text EXISTING HVAC SUPPLY GRILL. TO BE RELOCATED AS SHOWN ON PLAN. CONNECT TO NEW SYSTEM AS SHOWN ON PLANS.

AutoCAD SHX Text

AutoCAD SHX Text

NEW HVAC SUPPLY GRILL.

AutoCAD SHX Text

APPROXIMATE LOCATION OF NEW HVAC CONDENSERS. NEW CONDENSERS TO REPLACE EXISTING CONDENSERS AND USE EXISTING LOCATION.

GENERAL NOTES CODES & DESIGN CRITERIAELECTRICAL LEGEND

SYMBOL DESCRIPTION

GRND INDICATED GROUND

PNL INDICATED PANEL

WP INDICATED WEATHER-PROOF (NEMA 3R)

SWITCH

3 WAY SWITCH

MOTION SENSOR SWITCH

RECEPTACLE

GFI RECEPTACLE

ARC FAULT RECEPTACLE

WEATHER PROOF RECEPTACLE

COUNTER TOP RECEPTACLE

FLOOR RECEPTACLE

TV OUTLET

JUNCTION BOX

EXHAUST FAN

ELECTRICAL PANEL

S3

GFI

S

ARC

WP

TV

CTR

SM

LIGHTING LEGEND

SYMBOL DESCRIPTION

6" RECESSED LED CAN LIGHT - LITHONIA LIGHTING - LDN6 40/15 - 17.5W

SAME AS ABOVE WITH EMERGENCY BALLAST

24"X48" SURFACE MOUNTED LED - LITHONIA LIGHTING - CPANL 2X4 AL06 SWW7 M2 - 55W

LED EMERGENCY LIGHT - LITHONIA LIGHTING - ELM2L

MICRO LED EXIT LIGHT/SIGN COMBO - THE EXIT LIGHT CO. - COMBOJR-R

EXIT SIGNS

HIGH/LOW EXIT SIGNS

SWITCH

3 WAY SWITCH

MOTION SENSOR SWITCH

LIGHTING TIMER SWITCH

H/L H/L

S3

S

SM

TC

E0.1

NTS

I.R.

EL

EC

TR

IC

AL

C

O

VE

R

SH

EE

T

SHEET:

IRON ROCK

GROUP

Building on Solid Foundations

460 E. 300 SOUTH

KANAB, UTAH 84741

435-644-2031 www.ironrockeng.com

R

EV

SCALE:

DRAWN BY:

IN

IT

IA

L

SU

B

M

IT

TA

L:

D A

TE

D

ES

C R

IP

TI

O N

R

EV

IS

IO

N

9/

/2

© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,

DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL

PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS

AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE

COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS

AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION, DISTRIBUTION,

PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN WHOLE OR IN

PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM IRON ROCK

GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS PROHIBITED.

W . 3

N

. K

AN

AB

, U

TA

H

KA

N

E C

O U

N

TY

A

SS

ES

SO

R S

O

FF

IC

E

R

EN

O

VA

TI

O

N 9/

8/

THOMAS W.

AVANT

#5561917

RE

E

NI

G

NE

LANOISSEFORP

DERETSI G E R

STATE OF U TAH

Thomas Avant

9/24/2026

AutoCAD SHX Text

JURISDICTION:

AutoCAD SHX Text

KANAB, UTAH

AutoCAD SHX Text

ELECTRICAL CODE:

AutoCAD SHX Text

2020 (NEC) NATIONAL ELECTRICAL CODE

AutoCAD SHX Text

ENERGY CODE:

AutoCAD SHX Text

2021 IECC

AutoCAD SHX Text

1. FINAL CONNECTIONS & ROUGH-IN REQUIREMENTS TO EQUIPMENT FINAL CONNECTIONS & ROUGH-IN REQUIREMENTS TO EQUIPMENT SHALL BE PER MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 2. CONTRACTOR SHALL REVIEW ARCHITECTURAL, STRUCTURAL, CONTRACTOR SHALL REVIEW ARCHITECTURAL, STRUCTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID. 3. CONTRACTOR SHALL VISIT SITE PRIOR TO BID AND VERIFY THAT CONTRACTOR SHALL VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL REPORT DISCREPANCIES TO THE ARCHITECT AND INCLUDE IN HIS BID ALL COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 4. PROPOSED SUBSTITUTIONS OF ELECTRICAL EQUIPMENT OR REQUEST PROPOSED SUBSTITUTIONS OF ELECTRICAL EQUIPMENT OR REQUEST FOR "OR EQUAL" OR "APPROVED EQUAL" LISTING SHALL BE SUBMITTED TO ARCHITECT NOT LESS THAN TEN (10) WORKING DAYS PRIOR TO BID. 5. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 6. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE AND NATIONAL CODES AND ORDINANCES. 7. PROVIDE PERMITS AND INSPECTIONS REQUIRED. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 8. PROVIDE RECORD DRAWINGS TO ARCHITECT. DRAWINGS SHALL PROVIDE RECORD DRAWINGS TO ARCHITECT. DRAWINGS SHALL INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS, ALTERATIONS, RE-ROUTINGS, ETC. 9. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN. 10. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO THE OWNER. 11. WIRE SHALL BE COPPER, 75 C RATED FOR GENERAL USE. FOR HID WIRE SHALL BE COPPER, 75°C RATED FOR GENERAL USE. FOR HIDFIXTURES AND WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90°C RATED, SIZESINDICATED ARE FOR INSTALLATION IN A MAXIMUM 30°C AMBIENTINSTALLATIONS. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 13. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS OR EQUIPMENT. 14. SYSTEMS SHALL BE COMPLETE, OPERABLE AND READY FOR SYSTEMS SHALL BE COMPLETE, OPERABLE AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE. 15. VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND UTILITIES, PIPING AND RACEWAY SYSTEMS PRIOR TO TRENCHING.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .