Kane County Assessors Office Renovation - Construction Document Summary
This is an architectural bid set for a Level 2 Alteration renovation project prepared by Iron Rock Group for Kane County Municipal Building Authority at 180 W 300 N, Kanab, Utah 84741. The project encompasses spatial reconfiguration, replacement of aged exterior building components, introduction of modernized interior finishes, and addition of a new roof awning to the existing 4,465 square-foot multi-tenant office facility. Key scope items include new standing seam metal roofing system with concealed gutters, removal and replacement of existing wood cladding with stucco finish, new interior drywall construction, installation of new windows and doors with RFID card readers on storefront entries, new acoustic ceiling tiles, carpet and luxury vinyl plank flooring, fresh paint finishes, new plumbing fixtures including ADA-compliant water closets and lavatories, new break room casework with stainless steel sink, and exterior sidewalk extensions with new concrete finish. The construction documents include general notes, finish specifications, accessibility requirements per ADA and ANSI A117.1 standards, and compliance with 2021 International Building Codes. The pre-bid conference and site walk-through is scheduled for Monday, September 14, 2026, at 10:00 am (MDT), with proposals due Monday, October 12, 2026, at 9:00 am (MDT), though Addendum #1 changes the bid opening to October 9, 2026, at 12:00 PM. Questions must be submitted by October 5, 2026, at 5:00 pm (MDT) to RFP Contact Matthew Henke at matt@ireng.net.
The renovation addresses the existing stick-built wood construction building with hip-truss roof framing and crawl-space foundation, focusing on Level 2 Alteration improvements to serve three tenant departments: Kane County DMV (620 SF existing office area), Kane County Assessors (1,420 SF existing office area), and Utah State University (690 SF existing office area), plus 925 SF of shared tenant spaces and 810 SF of circulation/service areas. Pricing terms, contract award amounts, and funding sources are not specified in the bid documents provided. The contractor is responsible for field verification of all as-built dimensions and existing conditions, immediate notification to the design team of discrepancies, coordination of all new work with existing infrastructure, and compliance with all local, state, and federal building codes including carbon monoxide detection, means of egress, structural, electrical, mechanical, and plumbing requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
FINISH SPECIFICATIONS ARE INCLUDED IN FINISH PLAN(S) AND/OR
SUPPORTING SPECIFICATION DOCUMENTS. FINISHES DENOTED IN ONE
OR THE OTHER ARE ASSUMED TO BE SYNONYMOUS WITH EACH
OTHER.
CONTRACTOR MUST NOTIFY THE DESIGN TEAM IN WRITING SHOULD
ANY CONFLICT IN FINISH SPECIFICATION BE NOTED.
CONSULT FINISH SCHEDULE(S) AND/OR ASSOCIATED SPECIFICATION
DOCUMENTS AS NECESSARY FOR FINISH PRODUCTS(S), MODEL(S),
MFR'S, ETC.
WHERE NOT EXPRESSLY SPECIFIED, CONTRACTOR TO PROVIDE FINISH
SUBMITTAL(S) TO DESIGN TEAM FOR FINAL APPROVAL.
WHERE NECESSARY, DESIGN DOCUMENTS MAY DEFER TO OWNER
PREFERENCE AND/OR SELECTION
PREPARE ALL FLOOR AND WALL SURFACES/SUBSTRATES FOR NEW
FINISHES. PROVIDE PROPER LEVELING AS REQUIRED AT DISSIMILAR
AND/OR UNEVEN FLOOR SURFACES. INSTALLATION OF FINISH
PRODUCTS TO FOLLOW MANUFACTURER'S INSTRUCTIONS.
ALL FLOORING MATERIALS TRANSITIONS SHALL OCCUR AT THE
CENTERLINE OF DOORS SEPARATING ROOMS. UNO. CONTRACTOR TO
COORDINATE DOOR THRESHOLD REQUIREMENTS WITH DOOR
HARDWARE SCHEDULE.
FINISHES @ ACCESSORY SPACES (E.G. CLOSETS, RECESSES, ETC.) TO
MATCH ADJACENT SPACES. UNO.
ALL TILE EDGES TO BE EQUIPPED WITH SCHLUTER EDGE TRIM AND
COVE BASE TYP. (OR APPROVED EQUAL).
IF NOT FULLY SPECIFIED AT TIME OF COSTING, CONTRACTOR WILL
ASSUME "ARCHITECTURAL-GRADE" QUALITY FINISHES UNLESS
SPECIFIED AS "BUILDER-GRADE" OR OTHERWISE.
CONTRACTOR TO PROVIDE STAINLESS STEEL CORNER-GUARD WALL
PROTECTION WHERE APPLICABLE U.N.O.
FINISH CALLOUTS:
GENERAL FINISH NOTES
CEILING
WALL
FLOOR
SHEET INDEX
A001 TITLE SHEET
A002 A003 A010 A011 A020 A100 A110 A120 A130 A200 A201 A300 A500 A510 A600
ACCESSIBILITY
EXISTING FACILITY DRAWINGS
DEMOLITION & NEW WORK PLAN
ARCHITECTURAL SITE PLAN
MAIN FLOOR PLAN
ROOF PLAN
ACCESSIBILITY
REFLECTED CEILING PLAN
FINISH PLAN
BUILDING ELEVATIONS
BUILDING ELEVATIONS
BUILDING SECTIONS
INTERIOR ELEVATIONS
ARCHITECTURAL DETAILS
DOOR & WINDOW SCHEDULES
1. CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE PRIOR TO
BIDDING AND CONSTRUCTION TO ASSESS EXISTING CONDITIONS. ANY
FINISHES, MATERIALS, ETC. NOT NOTED ARE ASSUMED TO MATCH
ADJACENT EQUIVALENTS OF THE EXISTING BUILDING.
1.1 WHERE EXISTING BUILDING ELEMENTS CANNOT BE
REASONABLY MATCHED, CONTRACTOR TO COORDINATE WITH
DESIGN TEAM AND OWNER FOR APPROVAL OF COMPARABLE
SUBSTITUTIONS.
2. AS-BUILT DRAWINGS ARE FROM GRID CENTER LINE OR FACE OF
EXISTING FINISHED SURFACE U.N.O.
3. AS-BUILT DRAWINGS, DIMENSIONS, SCHEDULES, ETC. ARE PROVIDED
BASED ON THE OBSERVABLE BUILDING AT THE TIME OF PLAN
DEVELOPMENT. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL AS-BUILT DIMENSIONS, SYSTEMS, CONDITIONS, ETC. SHOULD THE
CONTRACTOR FIND A DISCREPANCY OR SIGNIFICANT DIFFERENCE
BETWEEN AS-BUILT DRAWINGS AND EXISTING CONDITIONS, THEY MUST
NOTIFY THE DESIGN TEAM IMMEDIATELY.
4. VARIOUS PLAN SHEET SERIES ARE ASSUMED TO BE SYNONYMOUS
WITH EACH OTHER. THE INFORMATION GIVEN FOR ONE DISCIPLINE SET,
SHOULD BE ASSUMED FOR ALL.
5. CONTRACTOR TO REPORT ANY DISCREPANCIES DISCOVERED IN
WRITING TO THE DESIGN TEAM. WORK FOUND IN CONFLICT WITH
THE REQUIREMENTS INDICATED ON DRAWINGS SHALL BE CORRECTED
BY THE CONTRACTOR.
6. WHERE APPLICABLE, CONTRACTOR TO FIELD VERIFY SIZING OF ALL
ROUGH-INS FOR SPECIFIED DOORS AND WINDOWS.
7. REFERENCE DOOR AND WINDOW MANUFACTURER'S SPECIFICATIONS
FOR ACTUAL ROUGH OPENING SIZE. SEE ALSO A600 SHEET SERIES FOR
DOOR AND WINDOW TYPES.
8. DOORS IN PATH OF EGRESS SHALL BE EQUIPPED WITH HARDWARE
COMPLYING WITH CHAPTER 10 OF IBC.
9. DOORS REQUIRED TO BE ACCESSIBLE SHALL BE EQUIPPED WITH
HARDWARE COMPLYING WITH THE AMERICANS WITH DISABILITY ACT,
AS WELL AS ALL LOCAL AND STATE ACCESSIBILITY REGULATIONS.
COMPLIANCE WITH ONE CODE DOES NOT NECESSARILY GUARANTEE
COMPLIANCE WITH ALL.
10. ACCESSIBLE FACILITIES MUST BE DESIGNED TO COMPLY WITH ALL THE
REQUIREMENTS OF THE AMERICANS WITH DISABILITY ACT, AS WELL AS
ALL LOCAL AND STATE ACCESSIBILITY REGULATIONS. COMPLIANCE
WITH ONE CODE DOES NOT NECESSARILY GUARANTEE COMPLIANCE
WITH ALL.
11. FLOOR CLEAN OUTS ARE TO BE LOCATED IN INCONSPICUOUS PLACES
AND NOT IN MAIN ROOMS. ALL FLOOR CLEAN OUTS LOCATED IN
CARPETED AREAS ARE TO BE FITTED WITH CARPET INSERTS. ALL
CLEAN OUTS ARE TO BE FLUSH TO FLOOR/WALL.
12. GRID LINES SHOWN FOR EXISTING BUILDING STRUCTURE IS ASSUMED
BASED ON ORIGINAL BUILDING DRAWINGS. ANY DIMENSIONS SHOWN
TO/FROM EXISTING STRUCTURAL GRID LINES ARE SHOWN FOR
CONVENIENCE ONLY AND MUST BE FIELD VERIFIED BY THE
CONTRACTOR.
GENERAL PLAN NOTES
1. CENTER ACOUSTIC CEILING GRID IN SPACE. U.N.O.
2. CENTER LIGHT FIXTURES IN SOFFITS AND IN ROOMS. U.N.O. WHERE
THERE ARE MULTIPLE FITTINGS IN ROOMS, THESE ARE TO BE SPACED
EQUIDISTANTLY.
3. PRIOR TO ORDERING OR INSTALLING LIGHTING FIXTURES, LOCATIONS
AND QUANTITIES SHALL BE APPROVED BY LOCAL FIRE MARSHALL.
COORDINATE FIXTURE INSTALLATION WITH FIRE SENSING SYSTEMS.
4. CENTER SMOKE/CARBON MONOXIDE DETECTORS IN ACOUSTIC CEILING
TILES, WHERE OCCURS.
5. CENTER SPRINKLER HEADS IN ACOUSTIC CEILING TILES (IF APPLICABLE
PER CODE SPECIFICATION).
6. IF FACTORY FINISH IS NOT COMPATIBLE WITH CEILING COLOR, PAINT
ALL DIFFUSERS TO MATCH ADJACENT FINISH. U.N.O.
7. CONTRACTOR TO VERIFY QTY. & LOCATION OF CEILING MOUNTED
SPEAKERS, IF APPLICABLE.
8. PROVIDE BACK-UP EMERGENCY LIGHTING AS REQUIRED BY CODE.
REFER TO ELECTRICAL PLANS.
9. AT SUSPENDED ACOUSTIC CEILING AND FOR ALL OTHER FIXTURE
TYPES NOT LISTED: CENTER FIXTURE IN ACOUSTIC CEILING TILES,
WHERE OCCURS.
10. FIELD PAINT ALL CONDUIT, JUNCTION BOXES, AND HARDWARE TO
MATCH ADJACENT SURFACES.
GENERAL RCP NOTES
RCP LEGEND
NEW FINISHED
GYPBOARD CEILING
NEW EXTERIOR
FIBER CEMENT
SOFFIT
EXISTING
GYPBOARD CEILING
TO BE REPAIRED
AND REFINISHED
AS/IF REQUIRED
VENTED SOFFIT
1. REFERENCE ROOF PLAN (A110 SERIES) & BUILDING SECTIONS (A300
SERIES) FOR COMPLETE ROOF PLAN AND SECTION DETAILS.
2. ROOFING CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF
EXISTING ROOFING SYSTEMS AND PREPARATION OF ALL
SUBSURFACES FOR NEW ROOFING SYSTEMS WHERE NOTED.
3. CONTRACTOR IS RESPONSIBLE FOR REPAIRING/REPLACING ALL ROOF
DECKING, INSULATION, BLOCKING, ETC. FOUND TO BE DAMAGED,
ROTTED, ETC.
4. ALL MECHANICAL ROOFTOP UNITS, VENTING, DRAINS, ETC. IF SHOWN
ON ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. EXISTING
CONDITIONS GOVERN FOR NEW MECHANICAL DESIGNS AND
SPECIFICATIONS.
5. ROOFING CONTRACTOR IS RESPONSIBLE FOR INSTALLING PROPER
FLASHING AND CURBS BASED ON MECHANICAL UNIT NEEDS. ROOFING
CONTRACTOR IS RESPONSIBLE TO COORDINATE W/ MECHANICAL
CONTRACTOR TO VERIFY WHICH ROOFTOP ELEMENTS ARE BEING
REPLACED, UPDATED, OR ELIMINATED.
6. WHERE NEW-TO-EXISTING TRANSITIONS OCCUR, CONTRACTOR IS
RESPONSIBLE FOR ADEQUATE FLASHING AND WATER MITIGATION IN
LINE W/ INDUSTRY STANDARDS AND PRACTICE INCLUDING (BUT NOT
LIMITED TO) ROOF/WALL ABUTMENTS, PARAPETS, OVERFLOWS, EDGE,
ETC.
7. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING
SLOPES. IF PROPOSED ROOF HEIGHTS AND SLOPES CREATE CONFLICT
W/ EXISTING DRAINAGE, CONTRACTOR MUST NOTIFY THE DESIGN TEAM
IN WRITING IMMEDIATELY FOR APPROPRIATE DESIGN RESOLUTION.
GENERAL ROOF NOTES
ROOF LEGEND
STANDING SEAM METAL ROOF SYSTEM
STANDING SEAM METAL ROOF SYSTEM EXTENSION
@ = AT
ACT = ACOUSTIC CEILING TILE
AFF = AIR & EQUIPMENT ETC. N/A
AFF = ABOVE FINISH FLOOR
ALUM = ALUMINUM
ANOD = ANODIZED
ARCH = ARCHITECTURAL
BDRM = BEDROOM
BRK = BRICK
BSMT = BASEMENT
BLK = BLOCK
BOT = BOTTOM
CA = CONSTRUCTION ADMINISTRATION
CD = CONSTRUCTION DOCUMENT(S)
CIRNL = CIRCULAR
CIP = CAST IN PLACE
CJ = CONTROL JOINT
CLG = CEILING
CLR = CLEAR
CMU = CONCRETE MASONRY UNIT
CNTR = COUNTERTOP
COL = COLUMN
COMP = COMPOSITE
CONT = CONTINUOUS
CT = CERAMIC TILE
CPTB = CARPET BASE
DBL = DOUBLE
DEMO = DEMOLITION
DD = DESIGN DEVELOPMENT
DIAM = DIAMETER
DIM = DIMENSION
DNS = DIMENSIONS
DN = DOWN
DR = DOOR
DWG = DRAWING
EA = EACH
EJ = EXPANSION JOINT
ELEC = ELECTRICAL
ELEV = ELEVATION (OR) ELEVATOR
EPDM = ETHYLENE PROPYLENE DIENE M-CLASS
EQ = EQUAL
EX = EXISTING
EXT = EXTERIOR
FD = FLOOR DRAIN (OR) FIRE DEPARTMENT
FEC = FIRE EXTINGUISHER CABINET
FF = FINISHED FACE (OR) FINISHED FLOOR
FFE = FINISHED FLOOR ELEVATION
FF&E = FURNITURE, FIXTURES, & EQUIPMENT
FFL = FINISHED FLOOR LEVEL
FIN = FINISH
FLT = FIXTURE
FLR = FLOOR
FLT = FLUTED METAL
FND = FOUNDATION
FO = FACE OF
FOF = FACE OF FINISH
FS = FULL SIZE
GALV = GALVANIZED
GWB = GYPSUM WALL BOARD
HC = HOLLOW CORE
HCW = HOLLOW CORE WOOD
HDWR = HARDWARE
HGT = HEIGHT
HM = HOLLOW METAL
HMF = HOLLOW METAL FRAME
HP = HIGH POINT
HR = HOUR
HVAC = HEATING, VENTILATION, & AIR CONDITIONING
ID = INSIDE DIAMETER
INT = INTERIOR
JT = JOINT
MECH = MECHANICAL
MEP = MECHANICAL, ELECTRICAL, PLUMBING
MBRN = MEMBRANE
MFR = MANUFACTURER
MTL = METAL
NIC = NOT IN CONTRACT
NA = NOT APPLICABLE
NOM = NOMINAL
NTRL = NATURAL
NTS = NOT TO SCALE
OC = ON CENTER
OH = OVERHEAD OR OPPOSITE HAND
OPP = OPPOSITE
OR = OR
PC = PRE-CAST CONCRETE
PD = POCKET DOOR
PLUMB = PLUMBING
PLYW = PLYWOOD
PRFIN = PREFINISHED
PT = PRESSURE TREATED
PNL = PANEL
PVC = POLYVINYL CHLORIDE
RBR = RUBBER
RCP = REFLECTED CEILING PLAN
RD = ROOF DRAIN
REQD = REQUIRED
RM = ROOM
SGWD = SOLID CORE WOOD DOOR
SD = SMOKE DETECTOR
SIM = SIMILAR
SPCFD = SPECIFICATION/SPECIFIED
SPK = SPRINKLER OR SPEAKER
SS = STAINLESS STEEL
ST = STONE TILE
STC = SOUND TRANSMISSION COEFFICIENT
STL = STEEL
STR = STRIP
STRS = STAIRS
STRUCT = STRUCTURE/STRUCTURAL
T&G = TONGUE & GROOVE
TEL = TELEPHONE
TLT = TOILET
TME = TO MATCH EXISTING
TO = TOP OF
TOC = TOP OF CONCRETE
TOS = TOP OF STEEL
TYP = TYPICAL
UNO = UNLESS NOTED OTHERWISE
VB = VINYL BASE
VIF = VERIFY IN FIELD
VP = VISION PANEL
VT = TILE
W = WITH
WD = WOOD
ABBREVIATIONS LEGEND
1. DOOR HARDWARE SCHEDULE
DEFERRED SUBMITTALS
PROJECT NAME: KANE COUNTY DMV & ASSESSOR OFFICE RENOVATION
LOCATION: 180 W 300N,
KANAB, UT 84741
OWNER: KANE COUNTY MUNICIPAL BUILDING AUTHORITY
OWNER REP: KRISTIAN RAMSAY
PHONE #: (435) 313-5871
DESIGN: IRON ROCK GROUP
ADDRESS: P.O. BOX 55, KANAB, UTAH 84741
PHONE #: (435) 644-2031
FAX #: (435) 644-2969
STRUCTURAL: IRON ROCK GROUP
ADDRESS: P.O. BOX 55, KANAB, UTAH 84741
PHONE #: (435) 644-2031
FAX #: (435) 644-2969
MEP: IRON ROCK GROUP
ADDRESS: P.O. BOX 55, KANAB, UTAH 84741
PHONE #: (435) 644-2031
FAX #: (435) 644-2969
ZONE: C3
FIRE DISTRICT: KANAB CITY
CONTRACTOR: TBD
PROJECT CONTACTS & COORDINATION
A. CONTRACTOR SHALL COORDINATE REQUIREMENTS OF THE DRAWINGS
BEFORE BEGINNING INSTALLATION OF WORK. REPORT DISCREPANCIES
BETWEEN THE CONSTRUCTION DOCUMENTS TO THE OWNER AND
FOUND IN CONFLICT WITH THE REQUIREMENTS INDICATED ON
DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR.
B. VERIFY THAT UTILITY REQUIREMENTS AND CHARACTERISTICS OF
OPERATING EQUIPMENT ARE COMPATIBLE WITH BUILDING UTILITIES.
COORDINATE WORK OF VARIOUS CONSTRUCTION TRADES HAVING
INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTING
TO, AND PLACING IN SERVICE OF SUCH EQUIPMENT.
C. COORDINATE SIZES REQUIREMENTS AND INSTALLATION OF
MECHANICAL AND ELECTRICAL WORK INDICATED ON DRAWINGS.
VERIFY FINAL ROUGH-IN AND LOCATION, SIZES FOR MECHANICAL
EQUIPMENT, LOCATION AND SIZES OF EQUIPMENT FOR PADS AND
BASES, AND REQUIREMENTS FOR POWER AND WATER OR DRAIN
INSTALLATION WITH EQUIPMENT MANUFACTURERS BEFORE
PROCEEDING WITH INSTALLATION.
D. COMPLY WITH INSTALLATION REQUIREMENTS OF MANUFACTURER'S
INSTRUCTIONS AND APPROVED SHOP DRAWINGS.
COORDINATION:
PROJECT DESCRIPTION & DATA
EXISTING OFFICE AREA (DMV): = 620 SF
EXISTING OFFICE AREA (ASSESSORS): = 1,420 SF
EXISTING OFFICE AREA (USU): = 690 SF
EXISTING SHARED TENANT SPACES = 925 SF
EXISTING CIRCULATION/SERVICES = 810 SF
TOTAL EXISTING AREA TO REMAIN: = 4,465 SF
ADDITION OFFICE AREA = 0 SF
TOTAL BUILDING AREA: = 4,465 SF
PROJECT DATA:
THESE CONSTRUCTION DOCUMENTS REPRESENT RENOVATION & ROOF
ADDITION TO THE COUNTY'S EXISTING FACILITY. THE EXISTING FACILITY
FUNCTIONS AS A MULTI-TENANT OFFICE SPACE FOR VARIOUS DEPARTMENTS
AND COUNTY SERVICES.
THE EXISTING STRUCTURE IS TYPICAL STICK-BUILT WOOD CONSTRUCTION
WITH HIP-TRUSS ROOF FRAMING AND A CRAWLSPACE-TYPE FOUNDATION.
GENERAL PROJECT SCOPE INTENT INCLUDES 1) SPATIAL RECONFIGURATION
CHANGES TO THE SPACE TO ACCOMMODATE CURRENT AND FUTURE
OPERATIONAL NEEDS. 2) REPLACEMENT OF AGED OR WEATHERED BUILDING
COMPONENTS ON THE EXTERIOR FACADES AND WALKWAYS. 3) INTRODUCTION
OF NEW/MODERNIZED FINISHES TO THE INTERIOR SPACES. 4) INTRODUCTION
OF A NEW ROOF AWNING.
CONSTRUCTION DOCUMENTS HAVE BEEN ESTABLISHED IN ORDER TO
ADDRESS SCOPE OF NEW WORK AND EXISTING CONSTRUCTION. THE SCOPE
OF NEW WORK MAY BE UNCLEAR. THE CONTRACTOR MUST OBTAIN IN WRITING
PRIOR CLARIFICATION OF THE EXTENT OF NEW WORK, UNLESS NOTED
OTHERWISE. THE CONTRACTOR WILL BE RESPONSIBLE FOR 1) FAMILIARIZING
THEMSELVES WITH THE SITE & BUILDING PRIOR TO CONSTRUCTION AND 2)
COORDINATING ALL NEW WORK WITH ALL EXISTING WORK ADJACENT TO OR IN
THE EXISTING BUILDING INCLUDING FINISHES, MATERIALS, SYSTEMS, ETC.
WHICH ARE ADJACENT TO OR IMPACTED BY THE SCOPE OF THE PROPOSED
WORK AS REQUIRED.
CODE REVIEW & CALCULATIONS
1.
2.
3.
4.
THIS PROJECT IS A RENOVATION OF AN EXISTING BUILDING. PER IEBC 603.1,
THIS PROJECT IS A LEVEL 2 ALTERATION AND INCLUDES AT MAXIMUM:
THE RECONFIGURATION OF SPACE
THE ADDITION OR ELIMINATION OF ANY DOOR/WINDOW
THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM
THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT
THE BUILDING USE AND OCCUPANCY IS NOT INTENDED TO CHANGE.
ALL BUILDING CODE CRITERIA APPLICABLE TO THE INTENDED WORK AREAS
INCLUDING ACCESSIBILITY (IEBC 305), BUILDING ELEMENTS AND MATERIALS
(IEBC 802), FIRE PROTECTION (IEBC 803), CARBON MONOXIDE DETECTION (IEBC
804), MEANS OF EGRESS (IEBC 805), STRUCTURAL (IEBC 806), ELECTRICAL (IEBC
807), MECHANICAL (IEBC 808), PLUMBING (IEBC 809), AND ENERGY
CONSERVATION (IEBC 810), HAVE BEEN DETERMINED PER CHAPTER 8
(ALTERATIONS - LEVEL 2) OF THE INTERNATIONAL BUILDING CODE.
ALL WORK SHALL COMPLY WITH ALL CITY, COUNTY AND STATE BUILDING
CODES AND REGULATIONS, INCLUDING:
• 2021 INTERNATIONAL BUILDING CODE (IBC)
• 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
• 2021 INTERNATIONAL FIRE CODE (IFC)
• 2021 INTERNATIONAL FUEL GAS CODE (IFGC)
• 2021 INTERNATIONAL MECHANICAL CODE (IMC)
2023 NATIONAL ELECTRIC CODE (NEC)
• 2021 INTERNATIONAL PLUMBING CODE (IPC)
• ANSI A-117.1 2009 AS MODIFIED BY THE 2015 IBC
OCCUPANCY CLASSIFICATIONS:
• B (BUSINESS) INCLUDING CIVIC ADMINISTRATION
TYPE OF CONSTRUCTION:
• TYPE V-B
• NON-SPRINKLED
• NON-SEPARATED
BUILDING HEIGHT (PER TABLE 504.3):
OCC. (B) - NS - VB: = 40'-0" ALLOWED
19'-0" ACTUAL PROPOSED
NUMBER OF STORIES (PER TABLE 504.4):
OCC. (B) - NS - VB: = 2 STORIES ALLOWED
1 STORY EXISTING
BUILDING AREA (PER TABLE 506.2):
OCC. (B) - NS - VB: = 9,000 SF ALLOWED
4,465 SF ACTUAL, EXISTING
OCCUPANT LOAD (PER TABLE 1004.5):
B (BUSINESS AREAS) = 29.7 = 4,465 SF / 150 GROSS
30 OCCUPANTS TOTAL
EGRESS COMPONENTS:
• STAIRS AT 0.2" PER LOAD OR MIN. OF 44"
• OTHER 0.2" PER LOAD OR MIN. OF 32"
MEANS OF EGRESS:
• NUMBER OF EXITS: 2 MIN. PER SPACE
• CORRIDOR WIDTH: 44" MIN.
• COMMON PATH OF TRAVEL: 75'-0"
© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,
DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL
PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS
AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE
COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS
AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION,
DISTRIBUTION, PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN
WHOLE OR IN PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM
IRON ROCK GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS
PROHIBITED.
SHEET:
IRON ROCK
GROUP
Building on Solid Foundations
460 E. 300 SOUTH
KANAB, UTAH 84741
435-644-2031 www.ironrockeng.com
SCALE:
DRAWN BY:
IN
IT
IA
L
SU
B
M
IT
TA
L:
/0
8/
1/4" = 1'-0"
9/7/2026 7:01:17 PM
A001
TI
TL
E
SH
EE
T
KA
N
E C
O U
N
TY
A
SS
ES
SO
R S
O
FF
IC
E
R
EN
O
VA
TI
O
N
DW
W
N
, K an ab , U
T
1, U ni te d
St at es
NOTE: ARTISTIC RENDERINGS ARE FOR REFERENCE ONLY. REFER TO EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. PLANS AND TECHNICAL DRAWINGS TAKE PRECEDENCE
N.T.S.
N o.
D es cr ip tio n
D at e
1_
2" MAX
1_
4" MAX 1_
4" MAX 1_
2" MAX
60" MIN
" M
IN
12" MIN
36" MIN
12" MIN
" M
IN
" M
IN
60" MIN 48" MIN
" M
IN
30" MIN
" M
IN
48" MIN
36" MIN
X
X
60" MIN
" M
IN
9"
6" MAX
17"-25"
" M
IN
8" MIN
" M
IN
11" MIN
9" MIN
25" MAX
" M
IN
X
X
4" MAX
" M
IN
" M
AX
10" MAX
15" MAX
" M
AX
" M
AX
20" MAX
>20-25" MAX
" M
AX
" M
AX
10" MAX
" M
AX
> 10-24" MAX
" M
AX
" M
AX
32" MIN
32" MIN
32" MIN
18" MIN
" M
IN
" M
IN
12" MIN
36" MIN 60
" M
IN
42" MIN 54
" M
IN
22" MIN
" M
IN
" M
IN
22" MIN 24" MIN48
" M
IN
24" MIN
" M
IN
" M
IN
24" MIN 48
" M
IN
24" MIN
" M
IN
" M
AX
2" MAX
1_
2" MAX
TURNING SPACE
NTS (SHOW @ 3/8" = 1') 305
CLEAR FLOOR SPACE
NTS (SHOW @ 3/8" = 1')
TOE AND KNEE CLEARANCE
NTS (SHOW @ 3/8" = 1')
307a
PROTRUDING OBJECTS
NTS (SHOW @ 3/8" = 1')308a
UNOBSTRUCTED REACH
NTS (SHOW @ 3/8" = 1')
308b
OBSTRUCTED REACH
NTS (SHOW @ 3/8" = 1')
404a
DOORS AND DOORWAYS
NTS (SHOW @ 3/8" = 1')
404b
SWINGING DOOR MANEUVERING CLEARANCES
NTS (SHOW @ 3/8" = 1') 904
SALES AND SERVICE COUNTERS
NTS (SHOW @ 3/8" = 1')
FLOOR
NTS
TYPE OF USE
MANEUVERING
CLEARANCES AT
MANUAL
SWINGING DOORS
APPROACH
DIRECTION
DOOR SIDE PERPENDICULAR
TO DOORWAY
PARALLEL TO
DOORWAY
(a) FROM FRONT PULL 60 INCHES 18 INCHES
(b) FROM FRONT PULL 48 INCHES 0 INCHES***
(c) FROM HINGE
SIDE
PULL 60 INCHES 36 INCHES
(d) FROM HINGE
SIDE
PULL 54 INCHES 42 INCHES
(e) FROM HINGE
SIDE
PUSH 42 INCHES* 22 INCHES****
(f) FROM LATCH
SIDE
PULL 48 INCHES* 24 INCHES
(g) FROM LATCH
SIDE
PUSH 42 INCHES** 24 INCHES
NOTES:
• CIRCULAR SPACE: TURNING SPACE SHALL BE A CIRCULAR SPACE WITH A 60 INCH MINIMUM DIAMETER.
• THE CIRCULAR TURNING SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING
WITH SECTION 306 (ICC A117).
• T-SHAPED SPACE: THE TURNING SPACE SHALL BE A T-SHAPED SPACE WITHIN A 60-INCH MINIMUM SQUARE, WITH ARMS AND BASE 36 INCHES MINIMUM IN WIDTH.
• EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12 INCHES MINIMUM IN EACH DIRECTION, AND THE
BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES MINIMUM.
• THE T-SHAPED TURNING SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING
WITH SECTION 306 (ICC A117) ONLY AT THE END OF EITHER THE BASE OR ONE ARM.
• UNLESS OTHERWISE SPECIFIED, DOORS SHALL BE PERMITTED TO SWING INTO TURNING SPACES.
BASE
ARM ARM
NOTES:
• CHANGES IN LEVEL ARE NOT PERMITTED WITHIN THE CLEAR FLOOR SPACE.
• THE CLEAR FLOOR SPACE SHALL BE 48 INCHES MINIMUM IN LENGTH AND 30 INCHES MINIMUM IN WIDTH.
• CLEAR FLOOR SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 306
(ICC A117)/
• THE CLEAR FLOOR SPACE SHALL BE POSITIONED FOR EITHER FORWARD OR PARALLEL APPROACH TO AN ELEMENT.
• ONE FULL, UNOBSTRUCTED SIDE OF THE CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE
OR ADJOIN ANOTHER CLEAR FLOOR SPACE.
• WHERE THE CLEAR FLOOR SPACE IS POSITIONED FOR A PARALLEL APPROACH, THE ALCOVE SHALL BE 60 INCHES
MINIMUM IN WIDTH WHERE THE DEPTH EXCEEDS 15 INCHES.
• WHERE THE CLEAR FLOOR SPACE IS POSITIONED FOR A FORWARD APPROACH, THE ALCOVE SHALL BE 36 INCHES
MINIMUM IN WIDTH WHERE THE DEPTH EXCEEDS 24 INCHES.
(a) clear floor space size
(b) forward
(c) parallel
NOTES:
• SPACE BENEATH AN ELEMENT BETWEEN THE FLOOR AND 9 INCHES ABOVE THE FLOOR SHALL BE CONSIDERED
TOE CLEARANCE.
• TOE CLEARANCE SHALL BE PERMITTED TO EXTEND 25 INCHES MAXIMUM UNDER AN ELEMENT.
• WHERE TOE CLEARANCE IS REQUIRED AT AN ELEMENT AS PART OF A CLEAR FLOOR SPACE COMPLYING WITH
SECTION 305 (ICC A117), THE TOE CLEARANCE SHALL EXTEND 17 INCHES MINIMUM BENEATH THE ELEMENT.
• SPACE EXTENDING GREATER THAN 6 INCHES BEYOND THE AVAILABLE KNEE CLEARANCE AT 9 INCHES ABOVE
THE FLOOR SHALL NOT BE CONSIDERED TOE CLEARANCE.
• TOE CLEARANCE SHALL BE 30 INCHES MINIMUM IN WIDTH.
• SPACE BENEATH AN ELEMENT BETWEEN 9 INCHES AND 27 INCHES ABOVE THE FLOOR SHALL BE CONSIDERED
KNEE CLEARANCE.
• KNEE CLEARANCE SHALL BE PERMITTED TO EXTEND 25 INCHES MAXIMUM UNDER AN ELEMENT AT 9 INCHES
ABOVE THE FLOOR.
• WHERE KNEE CLEARANCE IS REQUIRED BENEATH AN ELEMENT AS PART OF A CLEAR FLOOR SPACE
COMPLYING WITH SECTION 305, THE KNEE CLEARANCE SHALL BE 11 INCHES MINIMUM IN DEPTH AT 9 INCHES
ABOVE THE FLOOR, AND 8 INCHES MINIMUM IN DEPTH AT 27 INCHES ABOVE THE FLOOR.
• CLEARANCE REDUCTION: BETWEEN 9 INCHES AND 27 INCHES ABOVE THE FLOOR, THE KNEE CLEARANCE SHALL BE PERMITTED TO BE REDUCED AT THE RATE OF 1 INCH IN DEPTH FOR EACH 6 INCHES IN HEIGHT.
• KNEE CLEARANCE SHALL BE 30 INCHES MINIMUM IN WIDTH.
(a) elevation
(b) plan
(a) elevation
(b) plan
TOE CLEARANCE
KNEE CLEARANCE
NOTES:
• OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE
FLOOR SHALL PROTRUDE 4 INCHES MAXIMUM HORIZONTALLY INTO THE CIRCULATION PATH.
• EXCEPTION: HANDRAILS SHALL BE PERMITTED TO PROTRUDE 41_
2 INCHES MAXIMUM.
NOTES:
• WHERE A FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BY 48 INCHES
MAXIMUM.
• THE LOW FORWARD REACH SHALL BE 15 INCHES MINIMUM ABOVE THE FLOOR.
• WHERE A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305 ALLOWS A PARALLEL APPROACH TO
AN ELEMENT AND THE EDGE OF THE CLEAR FLOOR SPACE IS 10 INCHES MAXIMUM FROM THE
ELEMENT, THE HIGH SIDE REACH SHALL BE 48 INCHES MAXIMUM.
• THE LOW SIDE REACH SHALL BE 15 INCHES MINIMUM ABOVE THE FLOOR.
NOTES:
• WHERE A HIGH FORWARD REACH IS OVER AN OBSTRUCTION, THE CLEAR FLOOR SPACE COMPLYING WITH
SECTION 305 (ICC A117) SHALL EXTEND BENEATH THE ELEMENT FOR A DISTANCE NOT LESS THAN THE
REQUIRED REACH DEPTH OVER THE OBSTRUCTION.
• THE HIGH FORWARD REACH SHALL BE 48 INCHES MAXIMUM ABOVE THE FLOOR WHERE THE REACH DEPTH IS 20
INCHES MAXIMUM.
• WHERE THE REACH DEPTH EXCEEDS 20 INCHES, THE HIGH FORWARD REACH SHALL BE 44 INCHES MAXIMUM
ABOVE THE FLOOR, AND THE REACH DEPTH SHALL BE 25 INCHES MAXIMUM.
• WHERE A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305 ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES MAXIMUM ABOVE THE FLOOR AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24 INCHES MAXIMUM.
• THE HIGH SIDE REACH SHALL BE 48 INCHES MAXIMUM ABOVE THE FLOOR FOR A REACH DEPTH OF 10 INCHES
MAXIMUM.
• WHERE THE REACH DEPTH EXCEEDS 10 INCHES, THE HIGH SIDE REACH SHALL BE 46 INCHES MAXIMUM ABOVE
THE FLOOR FOR A REACH DEPTH OF 24 INCHES MAXIMUM.
NOTES:
• DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32 INCHES MINIMUM.
• CLEAR OPENING WIDTH OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED
BETWEEN THE FACE OF DOOR AND STOP, WITH THE DOOR OPEN 90 DEGREES.
• OPENINGS MORE THAN 24 INCHES IN DEPTH AT DOORS AND DOORWAYS WITHOUT DOORS
SHALL PROVIDE A CLEAR OPENING WIDTH OF 36 INCHES MINIMUM.
• THERE SHALL BE NO PROJECTIONS INTO THE CLEAR OPENING WIDTH LOWER THAN 34 INCHES
ABOVE THE DOOR.
• PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE
THE FLOOR SHALL NOT EXCEED 4 INCHES.
(c) folding door
(a) hinged door
(b) sliding door
(a) front approach, pull side
(b) front approach, push side
(b2) front approach, push side, door provided with both closer and latch
(c) hinge approach, pull side
(d) hinge approach, pull side
(e) hinge approach, push side
(e2) hinge approach, push side, door provided with both closer and latch
(f) latch approach, pull side
(f2) latch approach, pull side, door provided with closer
(g) latch approach, push side (g2) latch approach, push side, door provided with closer
*ADD 6 INCHES IF CLOSER AND LATCH PROVIDED
**ADD 6 INCHES IF CLOSER PROVIDED
***ADD 12 INCHES BEYOND LATCH IF CLOSER AND LATCH PROVIDED
****ADD 12 INCHES BEYOND LATCH IF CLOSER AND LATCH PROVIDED.
MEASURE BEYOND HINGE SIDE
NOTES:
• ALL PORTIONS OF COUNTERS REQUIRED TO BE ACCESSIBLE SHALL BE LOCATED ADJACENT TO A
WALKING SURFACE COMPLYING WITH SECTION 403 (ICC A117).
• THE ACCESSIBLE PORTION OF THE COUNTERTOP SHALL EXTEND THE SAME DEPTH AS THE SALES AND
SERVICE COUNTERTOP.
• FOR PARALLEL APPROACH, A PORTION OF THE COUNTER SURFACE 36 INCHES MINIMUM IN LENGTH AND
36 INCHES MAXIMUM IN HEIGHT ABOVE THE FLOOR SHALL BE PROVIDED.
• FOR PARALLEL APPROACH, WHERE THE COUNTER SURFACE IS LESS THAN 36 INCHES IN LENGTH, THE
ENTIRE COUNTER SURFACE SHALL BE 36 INCHES MAXIMUM IN HEIGHT ABOVE THE FLOOR.
• A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305, POSITIONED FOR A PARALLEL APPROACH
ADJACENT TO THE ACCESSIBLE COUNTER, SHALL BE PROVIDED.
• FOR FORWARD APPROACH, A PORTION OF THE COUNTER SURFACE 30 INCHES MINIMUM IN LENGTH AND
36 INCHES MAXIMUM IN HEIGHT ABOVE THE FLOOR SHALL BE PROVIDED.
• A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305, POSITIONED FOR A FORWARD APPROACH TO
THE ACCESSIBLE COUNTER, SHALL BE PROVIDED.
• KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 306 SHALL BE PROVIDED UNDER THE
ACCESSIBLE COUNTER.
• AISLES SHALL COMPLY WITH SECTION 403.
• THE CHECKOUT COUNTER SURFACE SHALL BE 38 INCHES MAXIMUM IN HEIGHT ABOVE THE FLOOR.
• THE TOP OF THE COUNTER EDGE PROTECTION SHALL BE 2 INCHES MAXIMUM ABOVE THE TOP OF THE
COUNTER SURFACE ON THE AISLE SIDE OF THE CHECKOUT COUNTER.
• WHERE PROVIDED, CHECK WRITING SURFACES SHALL COMPLY WITH SECTION 902.4.
• SELF-SERVICE SHELVES AND DISPENSING DEVICES FOR TABLEWARE, DISHWARE, CONDIMENTS, FOOD
AND BEVERAGES SHALL COMPLY WITH SECTION 308.
• THE TOPS OF TRAY SLIDES SHALL BE 28 INCHES MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FLOOR.
• WHERE COUNTERS OR TELLER WINDOWS HAVE SECURITY GLAZING TO SEPARATE PERSONNEL FROM
THE PUBLIC, A METHOD TO FACILITATE VOICE COMMUNICATION SHALL BE PROVIDED.
• TELEPHONE HANDSET DEVICES, IF PROVIDED, SHALL COMPLY WITH SECTION 704.3.
NOTES:
• CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR BACKING OR
NO CUSION OR PAD.
• CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE
TEXTURE.
• THE PILE SHALL BE 1_
2 INCH MAXIMUM IN HEIGHT.
• EXPOSED EDGES OF CARPET SHALL BE FASTENED TO THE FLOOR AND SHALL HAVE TRIM ALONG THE ENTIRE LENGTH OF
THE EXPOSED EDGE.
• CARPET EDGE TRIM SHALL COMPLY WITH SECTION 303 (ICC A117).
• OPENINGS IN FLOOR SURFACES SHALL BE OF A SIZE THAT DOES NOT PERMIT THE PASSAGE OF A1_2 INCH DIAMETER
SPHERE, EXCEPT AS ALLOWED IN SECTIONS 407.4.3, 408.4.3, 409.4.3, 410.4, AND 805.1 (ICC A117).
• ELONGATED OPENINGS SHALL BE PLACED SO THAT THE LONG DIMENSION IS PERPENDICULAR TO THE PREDOMINANT
DIRECTION OF TRAVEL.
• VERTICAL CHANGES IN LEVEL OF1_
4 INCH MAXIMUM IN HEIGHT SHALL BE PERMITTED.
• CHANGES IN LEVEL GREATER THAN1_
4 INCH IN HEIGHT AND NOT MORE THAN1_
2 INCH MAXIMUM IN HEIGHT SHALL BE
BEVELED WITH A SLOPE NOT STEPPER THAN 1:2.
• CHANGES IN LEVEL GREATER THAN1_
2 INCH IN HEIGHT SHALL BE RAMPED AND SHALL COMPLY WITH SECTION 405 OR 405
(ICC A117).
PREDOMINANT DIRECTION OF TRAVEL
LONG DIMENSION PERPENDICULAR TO
DIRECTION OF TRAVEL
© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,
DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL
PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS
AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE
COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS
AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION,
DISTRIBUTION, PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN
WHOLE OR IN PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM
IRON ROCK GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS
PROHIBITED.
SHEET:
IRON ROCK
GROUP
Building on Solid Foundations
460 E. 300 SOUTH
KANAB, UTAH 84741
435-644-2031 www.ironrockeng.com
SCALE:
DRAWN BY:
IN
IT
IA
L
SU
B
M
IT
TA
L:
/0
8/
12" = 1'-0"
9/7/2026 7:01:18 PM
A002
AC
C
ES
SI
BI
LI
TY
KA
N
E C
O U
N
TY
A
SS
ES
SO
R S
O
FF
IC
E
R
EN
O
VA
TI
O
N
DW
W
N
, K an ab , U
T
1, U ni te d
St at es
N.T.S.
N o.
D es cr ip tio n
D
CL
01 1
CL
CL
CL
" M
AX
60" MIN
3'-73/4" 1'-41/4"
5'-0"
4'-10"
R1'-21/4" 60 .5
4' -0
R1'-9"
1'-9" 1'-103/4"
16-18"
17-19"
" M
IN
60" MIN
-1
9"
36" MIN
12" MIN
24" MIN
-3
6"
12" MAX
54" MIN
39-41"
42" MIN
" M
IN
-4 1"
-3
6"
24" MIN
42" MAX
1 1_ 2"
MIN
" M
IN
" M
IN
24" MIN
36" MAX
" M
AX
" M
IN
42" MAX
24" MIN
36" MAX
60" MIN
" M
IN
4" MAX
4" MAX
" M
IN
4" MAX
" M
IN
(W
AL
L
H U
N G
W .C
" M
IN
(F
LO
O
R M
O U
N
TE
D W
.C
12-18"
(CHILDREN)
16-18"
(ADULT)
" M
IN
56" MIN
(WALL MOUNTED W.C.)
59" MIN
(FLOOR MOUNTED W.C.)
9" MIN
6" MIN
12" MIN
6" MIN
6" MIN
6" MIN
17" MIN
11" MAX
48" MIN
" M
IN
17" MIN DEPTH
" M
AX
" M
AX
" M
IN
" M
IN
6" MAX TOE CLR.8" MIN KNEE CLR.
9" M
IN 34
" M
AX
40" MIN
40" MIN
60" MIN
60" MIN
A200 E1
ROOM LABEL
10'-0" x 10'-0"
CARPET
604a
WATER CLOSETS AND TOILET COMPARTMENT CLEARANCES
NTS (SHOW @ 3/8" = 1')
604b
WATER CLOSETS AND TOILET COMPARTMENTS - GRAB BARS
NTS (SHOW @ 3/8" = 1')
604c
WATER CLOSETS AND TOILET COMPARTMENTS - ACCESSORIES
NTS (SHOW @ 3/8" = 1') 604d
W.C. AND TOILET COMPARTMENTS - WHEELCHAIR ACCESSIBLE
NTS (SHOW @ 3/8" = 1')
604e
W.C. AND TOILET COMPARTMENTS - TOE CLEARANCE
NTS (SHOW @ 3/8" = 1')
LAVATORIES AND SINKS
NTS (SHOW @ 3/8" = 1')
KITCHENS AND KITCHENETTES
NTS (SHOW @ 3/8" = 1')
C1 A100
- 0'-6"
+ 1'-3"
AFF
0'-0"
T. O. SLAB - 1ST
0' - 0"
PLATE HT. (2ND FLOOR)
18' - 2"
A500
A501
A200 D1
A300 D2
D2 A300
1 1 A100
1 1
1 1
IR_TEXT_LEADER
IR_TEXT_LEADER
IR_TEXT_LEADER
1/4:12
SLOPE 12
IR_TEXT ANNOTATIVE (3/32" HT.)
IR_TEXT ANNOTATIVE (1/8" HT.)
IR_TEXT ANNOTATIVE (5/32" HT.)
IR_TEXT ANNOTATIVE (3/16" HT.)
IR_TEXT ANNOTATIVE (3/32" CENTERED)
IR_TEXT ANNOTATIVE (1/8" CENTERED)
IR_TEXT ANNOTATIVE (5/32" CENTERED)
IR_TEXT ANNOTATIVE (3/16"
CENTERED)
NOTES:
• THE WATER CLOSET SHALL BE LOCATED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE.
• THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM AND 18 INCHES MAXIMUM FROM
THE SIDE WALL OR PARTITION.
• WATER CLOSETS LOCATED IN THE AMBULATORY ACCESSIBLE COMPARTMENTS SPECIFIED IN SECTION
604.10 (ICC A117) SHALL HAVE THE CENTERLINE OF THE WATER CLOSET 17 INCHES MINIMUM AND 19 INCHES
MAXIMUM FROM THE SIDE WALL OR PARTITION.
• CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES MINIMUM IN WIDTH, MEASURED
PERPENDICULAR FROM THE SIDEWALL.
• CLEARANCE AROUND THE WATER CLOSET SHALL BE 56 INCHES MINIMUM IN DEPTH, MEASURED
PERPENDICULAR FROM THE REAR WALL.
• THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, PAPER DISPENSERS, SANITARY NAPKIN RECEPTACLES, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AT OTHER FIXTURES AND THE TURNING SPACE.
• NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE WITHIN THE REQUIRED WATER CLOSET CLEARANCE.
• THE HEIGHT OF WATER CLOSET SEATS SHALL BE 17 INCHES MINIMUM AND 19 INCHES MAXIMUM ABOVE THE
FLOOR, MEASURED TO THE TOP OF THE SEAT.
• SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION.
(a) wheelchair accessible water closets
(b) ambulatory accessible water closets
(d) water closet seat height
(c) size of clearance for water closet other fixtures not allowed within this area transfer side
NOTES:
• GRAB BARS COMPLYING WITH SECTION 609 (ICC A117) SHALL BE PROVIDED ON THE REAR WALL AND ON
THE SIDE WALL CLOSEST TO THE WATER CLOSET.
• FIXED SIDE-WALL GRAB BARS SHALL BE 42 INCHES MINIMUM IN LENGTH, LOCATED 12 INCHES MAXIMUM
FROM THE REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL.
• IN ADDITION, A VERTICAL GRAB BAR 18 INCHES MINIMUM IN LENGTH SHALL BE MOUNTED WITH THE
BOTTOM OF THE BAR LOCATED 39 INCHES MINIMUM AND 41 INCHES MAXIMUM ABOVE THE FLOOR AND WITH THE CENTER LINE OF THE BAR LOCATED 39 INCHES MINIMUM AND 41 INCHES MAXIMUM FROM THE
REAR WALL.
• THE REAR WALL GRAB BAR SHALL BE 36 INCHES MINIMUM IN LENGTH, AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 INCHES MINIMUM ON THE SIDE CLOSEST TO THE WALL, AND 24
INCHES MINIMUM ON THE TRANSFER SIDE.
(a) side wall grab bar for water closet
(b) rear wall grab bar for water closet
NOTES:
• FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC.
• HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 309 (ICC A117).
• FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET.
• TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 309.4.
• WHERE THE DISPENSER IS LOCATED ABOVE THE GRAB BAR, THE OUTLET OF THE DISPENSER SHALL BE LOCATED
WITHIN AN AREA 24 INCHES MINIMUM AND 36 INCHES MAXIMUM FROM THE REAR WALL.
• WHERE THE DISPENSER IS LOCATED BELOW THE GRAB BAR, THE OUTLET OF THE DISPENSER SHALL BE LOCATED
WITHIN AN AREA 24 INCHES MINIMUM AND 42 INCHES MAXIMUM FROM THE REAR WALL.
• THE OUTLET OF THE DISPENSER SHALL BE LOCATED 18 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE
FLOOR.
• DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY, OR DO NOT ALLOW CONTINUOUS PAPER FLOW.
• COAT HOOKS PROVIDED WITHIN TOILET COMPARTMENTS SHALL BE 48 INCHES MAXIMUM ABOVE THE FLOOR.
• SHELVES SHALL BE 40 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FLOOR.
(a) protruding dispenser below grab bar
(b) protruding dispenser above grab bar
(c) recessed dispenser
NOTES:
• THE MINIMUM AREA OF A WHEELCHAIR ACCESSIBLE COMPARTMENT SHALL BE 60 INCHES MINIMUM IN WIDTH
MEASURED PERPENDICULAR TO THE SIDE WALL, AND 56 INCHES MINIMUM IN DEPTH FOR WALL HUNG WATER CLOSETS, AND 59 INCHES MINIMUM IN DEPTH FOR FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR
TO THE REAR WALL.
• TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 404 (ICC A117), EXCEPT IF THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT DOOR CLEARANCE BETWEEN THE DOOR
SIDE OF THE STALL AND ANY OBSTRUCTION SHALL BE 42 INCHES MINIMUM.
• THE DOOR SHALL BE SELF-CLOSING.
• A DOOR PULL COMPLYING WITH SECTION 404.2.6 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH.
• TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE REQUIRED MINIMUM AREA OF THE COMPARTMENT.
• THE FARTHEST EDGE OF TOILET COMPARTMENT DOOR OPENING SHALL BE LOCATED IN THE FRONT WALL OR
PARTITION OR IN THE SIDE WALL OR PARTITION AS REQUIRED BY TABLE 604.9.3.1.
• WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL BE ARRANGED FOR LEFT-HAND OR RIGHT-HAND APPROACH TO
THE WATER CLOSET.
(d) wall hung water closet - adult
(e) floor-mounted water closet - adult floor-mounted and wall-hung water closet - children
(c) front partition
(b) side wall or partition
(a) wheelchair accessible compartment door openings - alternate door shall not swing into the required minimum area of the compartment
(a) elevation adult partition
(c) plan
(b) elevation children partition
NOTES:
• THE FRONT PARTITION AND AT LEAST ONE SIDE PARTITION SHALL PROVIDE A TOE CLEARANCE
OF 9 INCHES MINIMUM ABOVE THE FLOOR AND EXTENDING 6 INCHES BEYOND THE
COMPARTMENT SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS.
• GRAB BARS SHALL COMPLY WITH SECTIONS 609, 604.5.1, AND 604.5.2 (ICC A117).
NOTES:
• A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305.3 (ICC A117) POSITIONED FOR FORWARD APPROACH, SHALL BE PROVIDED.
• KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 306 SHALL BE PROVIDED.
• THE DIP OF THE OVERFLOW SHALL NOT BE CONSIDERED IN DETERMINING KNEE AND TOE CLEARANCES.
• THE FRONT OF LAVATORIES AND SINKS SHALL BE 34 INCHES MAXIMUM ABOVE THE FLOOR, MEASURED TO THE
HIGHER OF THE RIM OR COUNTER SURFACE.
• FAUCETS SHALL COMPLY WITH SECTION 309.
• HAND-OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM.
• WHERE ENHANCED REACH RANGE IS REQUIRED AT LAVATORIES, FACETS AND SOAP DISPENSER CONTROLS
SHALL HAVE A READ DEPTH OF 11 INCHES MAXIMUM OR, IF AUTOMATIC, SHALL BE ACTIVATED WITHIN A REACH
DEPTH OF 11 INCHES MAXIMUM.
• WATER AND SOAP FLOW SHALL BE PROVIDED WITH A REACH DEPTH OF 11 INCHES MAXIMUM.
• WATER SUPPLY AND DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE
CONFIGURED TO PROTECT AGAINST CONTACT.
• THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS.
(a) floor clearance
(b) side view (c) elevation
NOTES:
• IN PASS-THROUGH KITCHENS WHERE COUNTERS, APPLIANCES OR CABINETS ARE ON TWO OPPOSING
SIDES, OR WHERE COUNTERS, APPLIANCES OR CABINETS ARE OPPOSITE A PARALLEL WALL,
CLEARANCE BETWEEN ALL OPPOSING BASE CABINETS, COUNTER TOPS, APPLIANCES, OR WALLS WITHIN
KITCHEN WORK AREAS SHALL BE 40 INCHES MINIMUM.
• PASS-THROUGH KITCHENS SHALL HAVE TWO ENTRIES.
• IN KITCHENS ENCLOSED ON THREE CONTIGUOUS SIDES, CLEARANCE BETWEEN ALL OPPOSING BASE
CABINETS, COUNTERTOPS, APPLIANCES, OR WALLS WITHIN KITCHEN WORK AREAS SHALL BE 60 INCHES
MINIMUM.
• AT LEAST ONE WORK SURFACE SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 902 (ICC A117).
• THE SINK SHALL COMPLY WITH SECTION 606.
• A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305 SHALL BE PROVIDED AT EACH KITCHEN
APPLIANCE.
• ALL APPLIANCE CONTROLS SHALL COMPLY WITH SECTION 309.
• A CLEAR FLOOR SPACE POSITIONED ADJACENT TO THE DISHWASHER DOOR, SHALL BE PROVIDED.
• THE DISHWASHER DOOR IN THE OPEN POSITION SHALL NOT OBSTRUCT A CLEAR FLOOR SPACE FOR
THE DISHWASHER OR AN ADJACENT SINK.
• A CLEAR FLOOR SPACE, POSITIONED FOR A PARALLEL OR FORWARD APPROACH TO THE COOKTOP, SHALL BE PROVIDED.
• WHERE THE CLEAR FLOOR SPACE IS POSITIONED FOR A FORWARD APPROACH, KNEE AND TOE
CLEARANCE COMPLYING WITH SECTION 306 SHALL BE PROVIDED.
• THE UNDERSIDE OF THE COOKTOP SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PREVENT
BURNS, ABRASIONS, OR ELECTRICAL SHOCK.
• WHERE THE CLEAR FLOOR SPACE IS POSITIONED FOR A PARALLEL APPROACH, THE CLEAR FLOOR
SPACE SHALL BE CENTERED ON THE APPLIANCE.
• THE LOCATION OF CONTROLS SHALL NOT REQUIRE REACHING ACROSS BURNERS.
• THE OVEN DOOR IN THE OPEN POSITION SHALL NOT OBSTRUCT THE CLEAR FLOOR SPACE FOR THE
OVEN.
• SIDE-HINGED DOOR OVENS SHALL HAVE A WORK SURFACE POSITIONED ADJACENT TO THE LATCH SIDE
OF THE OVEN DOOR.
• BOTTOM-HINGED DOOR OVENS SHALL HAVE A WORK SURFACE POSITIONED ADJACENT TO ONE SIDE OF
THE DOOR.
• COMBINATION REFRIGERATORS AND FREEZERS SHALL HAVE AT LEAST 50% OF THE FREEZER
COMPARTMENT SHELVES, INCLUDING THE BOTTOM OF THE FREEZER, 54 INCHES MAXIMUM ABOVE THE
FLOOR WHEN THE SHELVES ARE INSTALLED AT THE MAXIMUM HEIGHTS POSSIBLE IN THE
COMPARTMENT.
• A CLEAR FLOOR SPACE, POSITIONED FOR A PARALLEL APPROACH TO THE REFRIGERATOR/FREEZER, SHALL BE PROVIDED.
• THE CENTERLINE OF THE CLEAR FLOOR SPACE SHALL BE OFFSET 24 INCHES MAXIMUM FROM THE
CENTERLINE OF THE APPLIANCE.
© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,
DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL
PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS
AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE
COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS
AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION,
DISTRIBUTION, PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN
WHOLE OR IN PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM
IRON ROCK GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS
PROHIBITED.
SHEET:
IRON ROCK
GROUP
Building on Solid Foundations
460 E. 300 SOUTH
KANAB, UTAH 84741
435-644-2031 www.ironrockeng.com
SCALE:
DRAWN BY:
IN
IT
IA
L
SU
B
M
IT
TA
L:
/0
8/
12" = 1'-0"
9/7/2026 7:01:18 PM
A003
AC
C
ES
SI
BI
LI
TY
KA
N
E C
O U
N
TY
A
SS
ES
SO
R S
O
FF
IC
E
R
EN
O
VA
TI
O
N
DW
W
N
, K an ab , U
T
1, U ni te d
St at es
12" = 1'-0"1ADA Details 02
N.T.S.
N o.
D es cr ip tio n
D
ES
A010
EW
A010
EN
A010
EE
A010
N
1/8" = 1'-0"ES EXISTING SOUTH ELEVATION
1/8" = 1'-0"EW EXISTING WEST ELEVATION
1/8" = 1'-0"EN EXISTING NORTH ELEVATION
1/8" = 1'-0"EE EXISTING EAST ELEVATION
1/4" = 1'-0"6 EXISTING BUILDING FLOOR PLAN
© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,
DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL
PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS
AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE
COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS
AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION,
DISTRIBUTION, PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN
WHOLE OR IN PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM
IRON ROCK GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS
PROHIBITED.
SHEET:
IRON ROCK
GROUP
Building on Solid Foundations
460 E. 300 SOUTH
KANAB, UTAH 84741
435-644-2031 www.ironrockeng.com
SCALE:
DRAWN BY:
IN
IT
IA
L
SU
B
M
IT
TA
L:
/0
8/
AS NOTED
9/7/2026 7:01:20 PM
A010
EX
IS
TI
N
G F
AC
IL
IT
Y
D R
AW
IN
G S
KA
N
E C
O U
N
TY
A
SS
ES
SO
R S
O
FF
IC
E
R
EN
O
VA
TI
O
N
DW
W
N
, K an ab , U
T
1, U ni te d
St at es
N o.
D es cr ip tio n
D
6 9
4 4 4
4 4 4 4
4 4 41
1 1
1 1
2 2 2 2 22
2 2
222 2 23
1. CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE PRIOR TO
BIDDING AND CONSTRUCTION TO ASSESS EXISTING CONDITIONS. ANY
FINISHES, MATERIALS, ETC. NOT NOTED ARE ASSUMED TO MATCH
ADJACENT EQUIVALENTS OF THE EXISTING BUILDING.
1.1 WHERE EXISTING BUILDING ELEMENTS CANNOT BE
REASONABLY MATCHED, CONTRACTOR TO COORDINATE WITH
DESIGN TEAM AND OWNER FOR APPROVAL OF COMPARABLE
SUBSTITUTIONS.
2. AS-BUILT DRAWINGS ARE FROM GRID CENTER LINE OR FACE OF
EXISTING FINISHED SURFACE U.N.O.
3. AS-BUILT DRAWINGS, DIMENSIONS, SCHEDULES, ETC. ARE PROVIDED
BASED ON THE OBSERVABLE BUILDING AT THE TIME OF PLAN
DEVELOPMENT. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL AS-BUILT DIMENSIONS, SYSTEMS, CONDITIONS, ETC. SHOULD THE
CONTRACTOR FIND A DISCREPANCY OR SIGNIFICANT DIFFERENCE
BETWEEN AS-BUILT DRAWINGS AND EXISTING CONDITIONS, THEY MUST
NOTIFY THE DESIGN TEAM IMMEDIATELY.
4. VARIOUS PLAN SHEET SERIES ARE ASSUMED TO BE SYNONYMOUS
WITH EACH OTHER. THE INFORMATION GIVEN FOR ONE DISCIPLINE SET,
SHOULD BE ASSUMED FOR ALL.
5. CONTRACTOR TO REPORT ANY DISCREPANCIES DISCOVERED IN
WRITING TO THE DESIGN TEAM. WORK FOUND IN CONFLICT WITH
THE REQUIREMENTS INDICATED ON DRAWINGS SHALL BE CORRECTED
BY THE CONTRACTOR.
6. WHERE APPLICABLE, CONTRACTOR TO FIELD VERIFY SIZING OF ALL
ROUGH-INS FOR SPECIFIED DOORS AND WINDOWS.
7. REFERENCE DOOR AND WINDOW MANUFACTURER'S SPECIFICATIONS
FOR ACTUAL ROUGH OPENING SIZE. SEE ALSO A600 SHEET SERIES FOR
DOOR AND WINDOW TYPES.
8. DOORS IN PATH OF EGRESS SHALL BE EQUIPPED WITH HARDWARE
COMPLYING WITH CHAPTER 10 OF IBC.
9. DOORS REQUIRED TO BE ACCESSIBLE SHALL BE EQUIPPED WITH
HARDWARE COMPLYING WITH THE AMERICANS WITH DISABILITY ACT,
AS WELL AS ALL LOCAL AND STATE ACCESSIBILITY REGULATIONS.
COMPLIANCE WITH ONE CODE DOES NOT NECESSARILY GUARANTEE
COMPLIANCE WITH ALL.
10. ACCESSIBLE FACILITIES MUST BE DESIGNED TO COMPLY WITH ALL THE
REQUIREMENTS OF THE AMERICANS WITH DISABILITY ACT, AS WELL AS
ALL LOCAL AND STATE ACCESSIBILITY REGULATIONS. COMPLIANCE
WITH ONE CODE DOES NOT NECESSARILY GUARANTEE COMPLIANCE
WITH ALL.
11. FLOOR CLEAN OUTS ARE TO BE LOCATED IN INCONSPICUOUS PLACES
AND NOT IN MAIN ROOMS. ALL FLOOR CLEAN OUTS LOCATED IN
CARPETED AREAS ARE TO BE FITTED WITH CARPET INSERTS. ALL
CLEAN OUTS ARE TO BE FLUSH TO FLOOR/WALL.
12. GRID LINES SHOWN FOR EXISTING BUILDING STRUCTURE IS ASSUMED
BASED ON ORIGINAL BUILDING DRAWINGS. ANY DIMENSIONS SHOWN
TO/FROM EXISTING STRUCTURAL GRID LINES ARE SHOWN FOR
CONVENIENCE ONLY AND MUST BE FIELD VERIFIED BY THE
CONTRACTOR.
GENERAL PLAN NOTES
EXISTING WALLS TO REMAIN.
NEW WALLS TO BE CONSTRUCTED.
EXISTING WALLS TO BE DEMOLISHED.
N
© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,
DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL
PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS
AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE
COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS
AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION,
DISTRIBUTION, PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN
WHOLE OR IN PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM
IRON ROCK GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS
PROHIBITED.
SHEET:
IRON ROCK
GROUP
Building on Solid Foundations
460 E. 300 SOUTH
KANAB, UTAH 84741
435-644-2031 www.ironrockeng.com
SCALE:
DRAWN BY:
IN
IT
IA
L
SU
B
M
IT
TA
L:
/0
8/
AS NOTED
9/7/2026 7:01:20 PM
A012
D
EM
O
LI
TI
O
N
N
EW
W O
R K
PL
AN
KA
N
E C
O U
N
TY
A
SS
ES
SO
R S
O
FF
IC
E
R
EN
O
VA
TI
O
N
DW
W
N
, K an ab , U
T
1, U ni te d
St at es
1/4" = 1'-0"1 DEMOLITION & NEW WORK PLAN
KEYNOTE LEGEND
KEY VALUE KEYNOTE TEXT
1 DENOTES EXISTING WALL(S)/DOOR(S) TO BE REMOVED
2 EXISTING DOOR FRAMES ARE TO BE PAINTED. EXISTING DOOR SLABS ARE TO BE SANDED AND
REFINISHED TO BE UNIFORM IN STAIN AND COLOR. ALL DOOR HARDWARE TO BE REPLACED (HANDLES, HINGES, ETC.)
3 EXISTING DOOR TO BE REMOVED. MODIFY AND/OR INFILL EXISTING OPENING PER NEW CONSTRUCTION
PLANS
4 EXISTING WINDOW TO BE REMOVED. REFER TO SCHEDULES AND ELEVATIONS FOR NEW WINDOW
SYSTEMS WITHIN EXISTING OPENING AND/OR CLOSURE OF OPENING.
5 EXISTING STORE FRONT DOORS TO BE REPLACED AND EQUIPPED WITH RFID CARD READERS.
6 NEW INTERIOR DRY WALLING TO BE CONSTRUCTED. REFER TO FINISHES PLAN FOR ADDITIONAL
INFORMATION.
7 NEW WINDOW SYSTEM WITHIN EXISTING WALL PER SCHEDULE.
9 NEW/RELOCATED DOOR PER SCHEDULE TO MATCH REFURBISHED FINISH ON EXISTING DOOR FRAMES
AND DOOR SLABS
10 NEW EXTERIOR DOOR WITHIN EXISTING EXTERNAL WALL. CARE TO BE TAKEN TO PRESERVE EXISTING
ADJACENT STONE FINISH
12 DENOTES NEW STOREFRONT TO BE CONSTRUCTED. SEE SCHEDULE FOR ADDITIONAL INFORMATION 14 EXISTING DOOR & STOREFRONT TO REMAIN UNCHANGED.SUN CONTROL WINDOW FILM TO BE APPLIED TO
ALL GLASS PANELS.
N o.
D es cr ip tio n
D
77497849
A A
B B
EXISTING RAMP TO REMAIN UNAFFECTED.
EXISTING CONCRETE STAIRWAY TO
REMAIN UNAFFECTED.
NEW CONCRETE SIDEWALK EXTENSION
TO MATCH NEW SIDEWALK FINISH.
EXISTING STEM WALL TO BE EXTENDED
FOR FULL LENGTH CURB @ NEW
CONCRETE SIDEWALK.
DENOTES LINE OF EXISTING ROOF.
ROOF EXTENTS TO REMAIN, SEE ROOF
PLAN AND SECTIONS FOR ADDITIONAL
INFORMATION ON NEW ROOF
COVERING.
A020
BLUE DASH DENOTES LINE OF NEW
ROOF EXTENSION OVER EXISTING
WALKWAY. REFER TO ROOF PLAN AND
SECTIONS FOR MORE INFORMATION.
NEW CAST STAIRS TO REPLACE
EXISTING. REFER TO CALLOUT FOR
MORE INFORMATION.
A020
LANDSCAPING TO ALL AREAS TO BE
REINSTATED/UPGRADED BY OTHERS.
EXISTING PARKING LOT UNAFFECTED.
DENOTES EXTENT OF EXISTING
SIDEWALK SLABS TO BE REMOVED
NEW CAST SIDEWALK TO REPLACE
EXISTING. REFER TO CALLOUT FOR
MORE INFORMATION.
NEW 3' WIDE CONCRETE SIDEWALK
EXTENSION ALONG PERIMETER OF
EXISTING AIR HANDLER PAD TO MATCH
NEW SIDEWALK FINISH.
GENERAL LOCATION OF NEW EXTERIOR
MECHANICAL UNITS. REFER TO
MECHANICAL DRAWINGS AND
SPECIFICATIONS FOR ADDITIONAL
INFORMATION ON UNIT LOCATION &
MOUNTING REQUIREMENTS
3' - 0" 17' - 8" 3' - 0"
23' - 8"
3'
0"
10' - 9" 0' - 8"
EXISTING STEM WALL TO BE
EXTENDED FOR FULL LENGTH
OF NEW CONCRETE FLOOR.
NEW CONCRETE SIDEWALK
EXTENSION TO MATCH
ADJACENT.
0' - 0"
0' - 0"
NEW JOINT LINES ON CENTER
DENOTES EXISTING RAMP
DENOTES EXISTING
CONCRETE STAIRWAY
NEW STEM WALL TO MATCH
ADJACENT HEIGHT AND FINISH.
11' - 5"
EXISTING CONCRETE PERIMETER TO BE REMEDIED/REPLACED WHERE EXCESSIVELY WEATHERED OR DAMAGED. IMAGES BELOW INDICATE AN ACCEPTABLE SIDEWALK FINISH VS AN UNACCEPTABLE FINISH.
GENERAL EXTERNAL FLOORING NOTE
ACCEPTABLE SIDEWALK FINISH:
EXTENT OF EXISTING SIDEWALK MATCHING THIS LEVEL OF FINISH IS TO REMAIN UNAFFECTED.
UNACCEPTABLE SIDEWALK FINISH:
EXTENT OF EXISTING SIDEWALK MATCHING THIS LEVEL OF WEATHERING OR DAMAGED IS TO BE REPLACED WITH A NEW
CAST FINISH TO MATCH EXISTING (ACCEPTABLE) SIDEWALK FINISH.
EXCESSIVE STAINING
CORRODED OR CRACKED EDGES TO
CONCRETE.
EXCESSIVE WEARING OF TOP LAYER AND
EXPOSURE OF AGGREGATE.
EXPOSURE TO GROUND OR EXCESSIVE
SPACING BETWEEN CAST ELEMENTS.
EXTENT OF FIRST STEP TO
MATCH LINE OF LOWER
WALKWAY.
3'
9" 3'
0"
5' - 3"
1' - 2"
0' - 7"
NEW STEM WALL TO MATCH
ADJACENT HEIGHT AND
FINISH.
0' - 0"
3 X EXISTING CONCRETE
SLABS TO BE REMOVED AND
REPLACED WITH NEW
CONCRETE SIDEWALK
EXISTING EXTENT OF
SIDEWALK FROM PARKING
LOT.
INDICATES LINE OF EXISTING
ROOF EXTENT ABOVE.
BLUE DASH DENOTES LINE
OF NEW ROOF EXTENSION
OVER EXISTING WALKWAY.
REFER TO ROOF PLAN AND
SECTIONS FOR MORE
INFORMATION.
0' - 0"
NEW FLOOR DRAIN TO BE
PROVIDED AND CONNECTED
TO EXISTING DRAIN LINE
BELOW. POSITION OF
EXISTING DRAIN TO BE
USED.
© ALL PLANS, CONSTRUCTION DOCUMENTS, RENDERINGS, MODELS,
DESIGN CONCEPTS, AND SO FORTH CONSTITUTE INTELLECTUAL
PROPERTY OF IRON ROCK GROUP AND ANY AFFILIATED PARTNERS
AND IS COPYRIGHT PROTECTED UNDER SECTION 102 OF THE
COPYRIGHT ACT (TITLE 17 OF THE UNITED STATES CODE), AS
AMENDED ON DECEMBER 1, 1990. ANY REPRODUCTION,
DISTRIBUTION, PUBLISHING, INFRINGEMENT, OR USE IN ANY WAY, IN
WHOLE OR IN PART, WITHOUT PRIOR WRITTEN AGREEMENT FROM
IRON ROCK GROUP CONSTITUTES VIOLATION OF COPYRIGHT AND IS
PROHIBITED.
SHEET:
IRON ROCK
GROUP
Building on Solid Foundations
460 E. 300 SOUTH
KANAB, UTAH 84741
435-644-2031 www.ironrockeng.com
SCALE:
DRAWN BY:
IN
IT
IA
L
SU
B
M
IT
TA
L:
/0
8/
AS NOTED
9/7/2026 7:01:21 PM
A020
AR
C
H
IT
EC
TU
R
AL
S
IT
E
PL
AN
KA
N
E C
O U
N
TY
A
SS
ES
SO
R S
O
FF
IC
E
R
EN
O
VA
TI
O
N
DW
W
N
, K an ab , U
T
1, U ni te d
St at es
1/8" = 1'-0"1 SITE PLAN
1/4" = 1'-0"2 PROPOSED RAMP LANDING EXTENSION
1/4" = 1'-0"3 PROPOSED NEW CONCRETE STAIR
N o.
D es cr ip tio n
D
131 SF
USU OFFICE
101 SF
USU OFFICE
103 SF
USU OFFICE
68 SF
STORAGE
101 SF
FLEX OFFICE
101 SF
FLEX OFFICE/DMV
50 SF
UNISEX
50 SF
UNISEX
30 SF
ELECTRICAL
54 SF
ADA
233 SF
DMV OFFICE
177 SF
DMV LOBBY
217 SF
CONFERENCE ROOM
117 SF
ASSESSOR OFFICE
123 SF
ASSESSOR OFFICE
174 SF
RYAN'S OFFICE
99 SF
ASSESSOR OFFICE
99 SF
ASSESSOR OFFICE
130 SF
ASSESSOR OFFICE
112 SF
USU OFFICE
112 SF
ASSESSOR OFFICE
392 SF
CONFERENCE ROOM
165 SF
PRODUCTION
55 SF
BREAK ROOM
178 SF
RECORDS
36 SF
IT
38 SF
JANITOR
13' - 11" 10' - 6"
4' - 9 1/2" 2' - 3 1/2" 17' - 3" 3' - 0" 4' - 7 1/2" 7' - 0" 8' - 4 1/2" 4' - 8 1/2" 2' - 0 1/2" 4' - 1 1/2" 10' - 11 1/2"
1/ 2"
1"
8'
1/
2"
3' - 10" 3' - 11 1/2"
E A201
N A201
S A200
W A200
74' - 7 1/2"
9' - 0" 2' - 6 1/2" 3' - 11 1/2" 4' - 5 1/2" 4' - 2" 4' - 3" 11' - 5 1/2" 2' - 10 1/2" 5' - 5" 5' - 1" 2' - 10 1/2" 7' - 0" 2' - 1" 9' - 6"
5'
4" 5'
6"
/2
2'
1/
2" 7'
7"
5'
/2
8' - 11 1/2" 2' - 0" 3' - 5" 4' - 11 1/2" 4' - 5 1/2" 4' - 1 1/2" 5' - 10" 6' - 0 1/2" 2' - 5 1/2" 4' - 3" 4' - 1 1/2" 3' - 3 1/2" 2' - 6" 11' - 0" 7' - 2 1/2"
74' - 7 1/2"
7'
1/
2" 7'
1/ 2"
4'
6" 2'
1/ 2"
9'
5" 9'
1"
2'
1/
2" 4'
9"
7'
2" 6'
9"
4'
5" 1'
1/ 2"
2'
2" 4'
1/ 2"
5'
1/
2"
2'
4'
/2
5' - 4 1/2" 2' - 10 1/2" 6' - 6" 1' - 7 1/2"
5' - 5 1/2"
5' - 4"
7'
8"
4' - 10 1/2" 2' - 3 1/2" 17' - 3"
A A
B B
A300
A300
A A A
A
A A
A
A
A
B AAAA
A
A
A
A
SF-01
SF-02
SF
-0
D01
D02 D05
D03 D04
D06D07
D08
D09
D10
D11
D12D13D14
D15
D16
D17
D18
D19
D20 D21
D22
D23 D24 D26
D25 D27
D28
D29
D30
D31
A500 1
27 27 27 27 27 27
27 27 27 27 2726
A500
DENOTES EXTENT OF EX.
CRAWL SPACE BELOW.
DENOTES LOCATION OF TRAP
DOOR TO CRAWL SPACE.
A
2' - 6"
2'
1/
2"
NEW EXTENT OF CHASE FOR
SERVICES RETICULATION.
1. CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE PRIOR TO
BIDDING AND CONSTRUCTION TO ASSESS EXISTING CONDITIONS. ANY
FINISHES, MATERIALS, ETC. NOT NOTED ARE ASSUMED TO MATCH
ADJACENT EQUIVALENTS OF THE EXISTING BUILDING.
1.1 WHERE EXISTING BUILDING ELEMENTS CANNOT BE
REASONABLY MATCHED, CONTRACTOR TO COORDINATE WITH
DESIGN TEAM AND OWNER FOR APPROVAL OF COMPARABLE
SUBSTITUTIONS.
2. AS-BUILT DRAWINGS ARE FROM GRID CENTER LINE OR FACE OF
EXISTING FINISHED SURFACE U.N.O.
3. AS-BUILT DRAWINGS, DIMENSIONS, SCHEDULES, ETC. ARE PROVIDED
BASED ON THE OBSERVABLE BUILDING AT THE TIME OF PLAN
DEVELOPMENT. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL AS-BUILT DIMENSIONS, SYSTEMS, CONDITIONS, ETC. SHOULD THE
CONTRACTOR FIND A DISCREPANCY OR SIGNIFICANT DIFFERENCE
BETWEEN AS-BUILT DRAWINGS AND EXISTING CONDITIONS, THEY MUST
NOTIFY THE DESIGN TEAM IMMEDIATELY.
4. VARIOUS PLAN SHEET SERIES ARE ASSUMED TO BE SYNONYMOUS
WITH EACH OTHER. THE INFORMATION GIVEN FOR ONE DISCIPLINE SET,
SHOULD BE ASSUMED FOR ALL.
5. CONTRACTOR TO REPORT ANY DISCREPANCIES DISCOVERED IN
WRITING TO THE DESIGN TEAM. WORK FOUND IN CONFLICT WITH
THE REQUIREMENTS INDICATED ON DRAWINGS SHALL BE CORRECTED
BY THE CONTRACTOR.
6. WHERE APPLICABLE, CONTRACTOR TO FIELD VERIFY SIZING OF ALL
ROUGH-INS FOR SPECIFIED DOORS AND WINDOWS.
7. REFERENCE DOOR AND WINDOW MANUFACTURER'S SPECIFICATIONS
FOR ACTUAL ROUGH OPENING SIZE. SEE ALSO A600 SHEET SERIES FOR
DOOR AND WINDOW TYPES.
8. DOORS IN PATH OF EGRESS SHALL BE EQUIPPED WITH HARDWARE
COMPLYING WITH CHAPTER 10 OF IBC.
9. DOORS REQUIRED TO BE ACCESSIBLE SHALL BE EQUIPPED WITH
HARDWARE COMPLYING WITH THE AMERICANS WITH DISABILITY ACT,
AS WELL AS ALL LOCAL AND STATE ACCESSIBILITY REGULATIONS.
COMPLIANCE WITH ONE CODE DOES NOT NECESSARILY GUARANTEE
COMPLIANCE WITH ALL.
10. ACCESSIBLE FACILITIES MUST BE DESIGNED TO COMPLY WITH ALL THE
REQUIREMENTS OF THE AMERICANS WITH DISABILITY ACT, AS WELL AS
ALL LOCAL AND STATE ACCESSIBILITY REGULATIONS. COMPLIANCE
WITH ONE CODE DOES NOT NECESSARILY GUARANTEE COMPLIANCE
WITH ALL.
11. FLOOR CLEAN OUTS ARE TO BE LOCATED IN INCONSPICUOUS PLACES
AND NOT…