8-03. Items Listing MP Revision 2025-09-29.docx
DOCX document 85 KB Posted
- Solicitation number
- UDOT260084MP
- Issued by
- Utah
About this file
This document is an Items List from the Utah Department of Transportation (UDOT) for Maintenance, Repair, and Installation of Intelligent Transportation Systems (ITS) Fiber-Optic infrastructure across Regions 1, 2, 3, and 4. The comprehensive line-item document details 999 specific service items related to traffic control, conduit installation, communication cabling, splicing, testing, labor, removal and restoration, environmental controls, and ITS equipment installation. The contract period is set to end on 03/31/2028 with no renewal options, and UDOT anticipates multiple contract awards to contractors who can provide line-item based construction services for fiber optic and Advanced Transportation Management Systems (ATMS) projects.
The pricing structure is based on unit pricing for each specific line item, with contractors required to indicate their pricing for performing work on a per-unit basis. Contractors must adhere to UDOT's standard specifications and drawings, and payment is contingent upon acceptance by the department. The solicitation allows for flexibility, with the state retaining the right to reopen the solicitation and add additional contractors at any time. The contract is designed for fast-turnaround, straightforward construction services, with an emphasis on precise documentation, specific technical requirements, and comprehensive service offerings ranging from traffic control to environmental management and infrastructure installation.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ITEMS LIST
Maintenance, Repair and, installation of the ITS Fiber-Optic System
For Regions 1, 2, 3, and 4
The Department will measure and pay based on each of the following criteria.
Payment is contingent upon acceptance by the Department.
Items are listed by Specification and in tables as follows:
| Bid Item Number |
| Bid Item Name |
| Unit of Measuring and Payment |
Additional Information
Traffic Control
| 1 |
| Traffic Control for Work Beyond the Shoulder – up to 1,000 feet |
| Lump sum with the following considerations: |
Includes all mobilization, materials, labor, workmanship, supervision, and equipment required for traffic control when work is beyond the shoulder. Plans will be submitted to the “Work Requester” ten days prior to the beginning of work. See UDOT’s current Standard Plans and Specifications and the MUTCD “Work Beyond the Shoulder” for a typical application. A Professional Engineer registered in Utah shall stamp Non-Standard plans.
| 2 |
| Traffic Control for Work – Shoulder Operation – up to 1,000 feet |
| Lump sum with the following considerations: |
Includes all mobilization, materials, labor, workmanship, supervision, and equipment required for traffic control when work requires shoulder operations. Traffic Control plans must be submitted to the “Work Requester” for approval ten days prior to beginning work. See UDOT’s current Standard Plans and Specifications for a typical application. A Professional Engineer registered in Utah shall stamp Non-Standard Plans.
| 3 |
| Traffic Control for Work – Single Lane Closure – up to 1,000 feet |
| Lump sum with the following considerations: |
Includes all mobilization, materials, labor, workmanship, supervision, and equipment required for traffic control when work requires closure of a single traffic lane. Traffic Control plans must be submitted to the “Work Requester” for approval ten days prior to beginning work. See UDOT’s current Standard Plans and Specifications for a typical application. A Professional Engineer registered in Utah shall stamp Non-Standard Plans.
| 4 |
| Traffic Control for Work – Two Lane Closure – up to 1,000 feet |
| Lump sum with the following considerations: |
Includes all mobilization, materials, labor, workmanship, supervision, and equipment required for traffic control when work requires closure of a two-traffic lane. Traffic Control plans must be submitted to the “Work Requester” for approval ten days prior to beginning work. See UDOT’s current Standard Plans and Specifications for a typical application. A Professional Engineer registered in Utah shall stamp Non-Standard Plans.
| 5 |
| Traffic Control in an Urban Intersection Under 50 MPH (TC-5) |
| Lump |
Includes all mobilization, materials, labor, workmanship, supervision, and equipment required for traffic control in an Urban Intersection under 50 MPH. Plans will be submitted to the “Work Requester" ten business days prior to the beginning of work. See UDOT's current Standard Plans and Specifications and the MUTCD "Work Beyond the Shoulder" for a typical application. A Professional Engineer registered in Utah shall stamp Non-Standard plans.
| 6 |
| Traffic Control Temporary Pedestrian Access Reroute (TC-6) |
| Lump |
Includes all mobilization, materials, labor, workmanship, supervision, and equipment required for traffic control for temporary pedestrian access reroute. Plans will be submitted to the "Work Requester" ten business days prior to the beginning of work. See UDOT's current Standard Plans and Specifications and the MUTCD "Work Beyond the Shoulder'' for a typical application. A Professional Engineer registered in Utah shall stamp Non-Standard plans.
| 7 |
| Traffic Control for Work - Project Specific (bid following contractor shortlist) |
| Project Specific |
This item is specific to individual projects. It will be bid separate from this procurement term contract. 3 contractors will be shortlisted to bid.
| 8 |
| Police Support |
| Invoice |
Requires police department invoice for payment. No mark-ups allowed on this item. 4 hours maximum unless otherwise approved.
| 9 |
| Additional Advance Warning Arrow Panel |
| Dev/Day |
Includes all mobilization, furnishing, setup, maintenance, and takedown of a complete advance warning panel. See UDOT’s current Standard Plans and Specifications for Traffic Control. This item is intended as additional warning within a full TC closure or as requested by UDOT. Not to be used under Short-Duration closures. Pre-approval and inspection are required.
| 10 |
| Attenuator Truck |
| Hour |
Includes all mobilization, furnishing and operation of a truck with UDOT approved attenuator with a certified driver. This item is intended as additional warning within a full TC closure or as requested by UDOT. Not to be used under Short-Duration closures. Pre-approval and inspection are required.
| 11 |
| Variable Message Sign (VMS) |
| Dev/Day |
Includes all mobilization, furnishing, setup, maintenance, and takedown of a complete portable VMS. . See UDOT’s current Standard Plans and Specifications for Traffic Control. This item is intended as additional warning within a full TC closure or as requested by UDOT. Not to be used under Short-Duration closures. Pre-approval and inspection are required.
| 12 |
| Rumble Strips |
| Day |
Includes all mobilization, furnishing, setup, maintenance, and takedown of a complete 2 lane setup of rumble strips. UDOT Standard Lane Closure will be paid separately.
| 13 |
| Flagging |
| Hour |
Includes all mobilization, labor, signs, devices, and permits for a complete flagging operation. See UDOT’s current Standard Plans and Specifications for Traffic Control. Use of non-certified flaggers will result in no-payment of this item.
Conduit
| 14 |
| 1 1/4-inch Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 15 |
| 2 inch Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 16 |
| 3 inch Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 17 |
| 1D Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 18 |
| 2D Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 19 |
| 4D Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 20 |
| 2 inch Galvanized Rigid Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 21 |
| 2 inch Liquid tight Flexible Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 22 |
| 4 inch Galvanized Rigid Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 23 |
| 4 inch Liquid tight Flexible Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 24 |
| 6 inch Galvanized Rigid Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 25 |
| 6 inch Liquid tight Flexible Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 26 |
| Individual 12.7/10mm Microduct |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish Microduct. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 27 |
| Individual 16/13mm Microduct |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 28 |
| Three 12.7/10mm Microducts with one No. 14 Locate Wire |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 29 |
| 18/14mm Microduct Bundle |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish conduit. Includes all incidental items, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to furnish the conduit. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 30 |
| No. 14 Locate Wire Placed in Existing Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to provide and install #14 locate wire inside existing conduit including termination to ground rod. Provide 14 AWG, RHH- USE- RHW- 2 stranded copper wire with green insulation.
| 31 |
| Detectable Pull Tape placed in existing conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to provide and install all detectable pull tape in existing conduit. Install according to UDOT specification section 13553 ITS conduit.
State Furnished Conduit
| 32 |
| Install State Furnished Conduit (up to eight conduits, 3 inch diameter or less) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 33 |
| Install State Furnished Conduit (more than eight conduits, 3 inch diameter or less) |
| Foot |
| 34 |
| Install One State Furnished Microduct in Existing Conduit |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to install all conduit. includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 35 |
| Install Three State Furnished Microducts in Existing Conduit |
Includes all mobilization, materials, labor, workmanship, and equipment required to install all conduit. includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings
Installation
| 36 |
| Install State Furnished Conduit (up to eight conduits, 3 inch diameter or less) Trench and Rock Saw adder for additional conduit |
placement up to a 4D, 16-1.25” conduits (or similar product bundle size) Foot
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings. Placement of additional conduit up to a 4D, 16 -1.25” conduits on all trench and Rock Saw line items. To be utilized in conjunction with Line items 37-68 when additional conduit is needed. Includes all mobilization, materials, labor, workmanship, and equipment required to install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ATMS Conduit and Standard Drawings.
| 37 |
| Trenching 3 feet Deep - Up to 500 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 38 |
| Trenching 3 feet Deep - 500 Feet to 2,000 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 39 |
| Trenching 3 feet Deep - 2,000 Feet to 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching. Backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 40 |
| Trenching 3 feet Deep - over 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Install according to the manufacturer's installation guide.
| 41 |
| Trenching 5 feet Deep - Up to 500 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 42 |
| Trenching 5 feet Deep - 500 Feet to 2,000 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items. Such as trenching, backfill sand fill 3 inches above the conduit, protection of area prior to the final layer. Warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 43 |
| Trenching 5 feet Deep - 2,000 Feet to 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 44 |
| Trenching 5 feet Deep - over 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations . Install according to manufacturer’s installation guide
| 45 |
| Trenching 4 feet Deep - In Pavement - Up to 500 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items. Such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 46 |
| Trenching 4 feet Deep - In Pavement - 500 Feet to 2,000 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 47 |
| Trenching 4 feet Deep - In Pavement - 2,000 Feet to 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 48 |
| Trenching 4 feet Deep - In Pavement - over 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection or area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 49 |
| Rock Saw 26 inches Deep and 5 inches Minimum Width - In/Outside of Pavement with Concrete Backfill - Up to 500 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 50 |
| Rock Saw 26 inches Deep and 5 inches Minimum Width - In/Outside of Pavement with Concrete Backfill - 500 Feet to 2,000 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 51 |
| Rock Saw 26 inches Deep and 5 inches Minimum Width - In/Outside of Pavement with Concrete Backfill - 2,000 Feet to 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 52 |
| Rock Saw 26 inches Deep and 5 inches Minimum Width - In/Outside of Pavement with Concrete Backfill - over 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to the final layer. Warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 53 |
| Rock Saw 3 feet Deep and 5 inches Minimum Width - In/Outside of Pavement with Concrete Backfill - Up to 500 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to the final layer. Warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 54 |
| Rock Saw 3 feet Deep and 5 inches Minimum Width - In/Outside of Pavement with Concrete Backfill - 500 Feet to 2,000 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Install according to the manufacturer’s installation guide.
| 55 |
| Rock Saw 3 feet Deep and 5 inches Minimum Width - In/Outside of Pavement with Concrete Backfill - 2,000 Feet to 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 56 |
| Rock Saw 3 feet Deep and 5 inches Minimum Width - In/Outside of Pavement with Concrete Backfill - over 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 57 |
| Rock Saw 4 feet Deep and 5 inches Minimum Width - In Pavement - Up to 500 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor. Workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to the final layer. Warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 58 |
| Rock Saw 4 feet Deep and 5 inches Minimum Width - In Pavement - 500 Feet to 2,000 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections , couplings , duct seal, bushings, adapters , and all other materials and labor necessary to complete installations. Install according to the manufacturer’s installation guide.
| 59 |
| Rock Saw 4 feet Deep and 5 inches Minimum Width - In Pavement - 2,000 Feet to 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 60 |
| Rock Saw 4 feet Deep and 5 inches Minimum Width - In Pavement - over 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters and all other materials and labor necessary to complete installations . See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 61 |
| Rock Saw 3 feet Deep and 5 inches Minimum Width - Outside Pavement - Up to 500 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill. Sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 62 |
| Rock Saw 3 feet Deep and 5 inches Minimum Width - Outside Pavement - 500 Feet to 2,000 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as drilling equipment, detectable pull tape, bend sections, couplings, duel seal, bushings, adapters , and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 63 |
| Rock Saw 3 feet Deep and 5 inches Minimum Width - Outside Pavement - 2,000 Feet to 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend section, Couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 64 |
| Rock Saw 3 feet Deep and 5 inches Minimum Width - Outside Pavement - over 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduit. See UOOT specification section 13553 ITS Conduit and Standard Drawings.
| 65 |
| Rock Saw 5 feet Deep and 5 inches Minimum Width - Outside Pavement - Up to 500 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete
| 66 |
| Rock Saw 5 feet Deep and 5 inches Minimum Width - Outside Pavement - 500 Feet to 2,000 Feet, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 67 |
| Rock Saw 5 feet Deep and 5 inches Minimum Width - Outside Pavement - 2,000 Feet to 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 68 |
| Rock Saw 5 feet Deep and 5 inches Minimum Width - Outside Pavement - over 5 miles, up to 1D, 4-1.25” conduits (or similar product bundle size) |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 69 |
| Directional Bore - 4 inch Diameter Product Bundle - 0 Feet to 2,000 Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 70 |
| Directional Bore - 4 inch Diameter Product Bundle - 2,000 Feet to 4,000 Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings , duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 71 |
| Directional Bore - 4 inch Diameter Product Bundle - 4,000 Feet to 10,000 Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings
| 72 |
| Directional Bore - 4 inch Diameter Product Bundle - 10,000+ Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Install according to the manufacturer’s installation guide.
| 73 |
| Directional Bore - 8 inch Diameter Product Bundle - 0 Feet to 2,000 Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 74 |
| Directional Bore - 8 inch Diameter Product Bundle - 2,000 Feet to 4,000 Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 75 |
| Directional Bore - 8 inch Diameter Product Bundle - 4,000 Feet to 10,000 Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Includes all conduits. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 76 |
| Directional Bore - 8 inch Diameter Product Bundle - 10,000+ Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as sand fill to the top of trench, repair of road, protection of area prior to final pavement layer, restriping of pavement, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawing AT6.
| 77 |
| Directional Bore - 12 inch Diameter Product Bundle - 0 Feet to 2,000 Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as sand fill to the top of trench. Repair of road, protection of area prior to final pavement layer, restriping of pavement. Warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 78 |
| Directional Bore - 12 inch Diameter Product Bundle - 2,000 Feet to 4,000 Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as flowable fill to the top or trench, repair of road, protection of area prior to final pavement layer, restriping of pavement, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UOOT specification section 13553 ITS Conduit and Standard Drawings.
| 79 |
| Directional Bore - 12 inch Diameter Product Bundle - 4,000 Feet to 10,000 Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, flowable fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters and all other materials and labor necessary to complete installations. Install according to the manufacturer’s installation guide.
| 80 |
| Directional Bore - 12-inch Diameter Product Bundle - 10,000+ Feet |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as flowable fill to the top of trench, repair of road, protection of area prior to final pavement layer, restriping of pavement, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations . See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 81 |
| 24 inch Wide Conduit Hanger Assembly between Bridge Girders |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as flowable fill to the top of trench, repair of road, protection of area prior to final pavement layer. Restriping of pavement, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 82 |
| 24 inch Wide Conduit Hanger Assembly under Bridge Deck Overhang |
| Foot |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as flowable fill to the top of trench, repair of road, protection of area prior to final pavement layer, restriping of pavement, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. See UDOT specification section 13553 ITS Conduit and Standard Drawings.
| 83 |
| Bridge Attached Conduit System - Project Specific (bid following contractor shortlist) |
| 84 |
| 30' Wood Pole with Riser Standoffs |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install one 30 foot wood pole with riser standoffs and up to two (2) ground anchors. Includes all incidental items such as anchor hardware, bolts and other hardware, excavation, compaction, and all other materials and labor necessary to complete installations for future aerial strand attachment. Aerial strand attachment paid for under separate item.
| 85 |
| 30' Wood Pole without Riser Standoffs and Ground Anchor |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install one 30 foot wood pole and up to two (2) ground anchors. Includes all incidental items such as bolts and other hardware, excavation, compaction, and all other materials and labor necessary to complete installations for future aerial strand attachment. Aerial strand attachment paid for under separate item.
| 86 |
| 3/8" Aerial Strand with Aerial Microduct MD7 Attached to Existing Pole(s) |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install a 3/8” steel messenger strand, with aerial 18mm/14mm MD7 microduct lashed. Includes all incidental items such as lashing material, microduct bundle, attachment to existing pole(s), anchors, anchor hardware, attachment hardware, and all other materials and labor necessary to complete installations for aerial strand.
| 87 |
| Conduit Entry into Existing Building |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install a 2” galvanized rigid conduit into existing building with up to two (2) NEMA-rated enclosures up to 50 feet total length, and up to two (2) wall cores. Conduit could be installed vertically, horizontally, or a combination of each. Includes all incidental items such as wall coring and sealing, conduit, bends, couplers, bushings, conduit anchors spaced every 5 feet maximum, hardware, detectable pull tape, adapters and all other materials and labor necessary to complete installations.
Proofing and Conduit Repair
| 88 |
| Spot Repair 1-1/4 inch Conduit less than 100 feet |
| 10-foot increments |
Includes all mobilization, materials, labor, workmanship, and equipment required to locate and repair all conduit. Includes all incidental items such as backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, bushings, adapters and all other materials and labor necessary to complete repair. The unit length of measurement for this item will be 10-foot lengths rounded to the next 10 foot length of conduit actually repaired. Surface restoration will be paid as a separate pay item.
| 89 |
| Spot Repair 2 inch Conduit less than 100 feet |
| 10 foot increments |
Includes all mobilization, materials, labor, workmanship, and equipment required to locate and repair all conduit. Includes all incidental items such as backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, bushings, adapters , and all other materials and labor necessary to complete repair. The unit length of measurement for this item will be 10 foot lengths rounded to the next 10 foot length of conduit actually repaired. Surface restoration will be paid as a separate pay item.
| 90 |
| Spot Repair 3 inch Conduit less than 100 feet |
| 10 foot increments |
Includes all mobilization, materials, labor, workmanship, and equipment required to locate and repair all conduit. Includes all incidental items such as backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, bushings, adapters, and all other materials and labor necessary to complete repair. The unit length of measurement for this item will be 10 foot lengths rounded to the next 10 foot length of conduit actually repaired. Surface restoration will be paid as a separate pay item.
| 91 |
| Spot Repair MD7 16/13 Microduct 100 feet |
| 10 foot increments |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Install according to the manufacturer’s installation guide.
| 92 |
| Spot Repair MD7 18/14 Microduct 100 feet |
| 10 foot increments |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Install according to the manufacturer’s installation guide.
| 93 |
| Spot Repair Individual Microduct (12.7/10 or 16/13) less than 100 feet |
| 10 foot increments |
Includes all mobilization, materials, labor, workmanship, and equipment required to furnish and install all conduit. Includes all incidental items such as trenching, backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, duct seal, bushings, adapters, and all other materials and labor necessary to complete installations. Install according to the manufacturer’s installation guide.
| 94 |
| Spot Repair 1D Conduit less than 100 feet |
| 10 foot increments |
Includes all mobilization, materials, labor, workmanship, and equipment required to locate and repair all conduit. Includes all incidental items such as backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, bushings, adapter, and all other materials and labor necessary to complete repair. The unit length of measurement for this item will be 10 foot lengths rounded to the next 10 foot length of conduit actually repaired. Surface restoration will be paid as a separate pay item.
| 95 |
| Spot Repair 2D Conduit less than 100 feet |
| 10 foot increments |
Includes all mobilization, materials, labor, workmanship, and equipment required to locate and repair all conduit. Includes all incidental items such as backfill, sand fill 3 inches above the conduit, protection of area prior to final layer , warning tape, detectable pull tape, bend sections, couplings, bushings, adapters and all other materials and labor necessary to complete repair. The unit length or measurement for this item will be 10 foot lengths rounded to the next 10 foot length of conduit actually repaired. Surface restoration will be paid as a separate pay item.
| 96 |
| Spot Repair 4D Conduit less than 100 feet |
| 10 foot increments |
Includes all mobilization, materials, labor, workmanship, and equipment required to locate and repair all conduit. Includes all incidental items such as backfill, sand fill 3 inches above the conduit, protection of area prior to final layer, warning tape, detectable pull tape, bend sections, couplings, bushings, adapters, and all other materials and labor necessary to complete repair.
This is the start of the file's text. The full file is on GovTribe.