5_APP_D_M-11_CHAIN_LINK_FNCING_Details.pdf

PDF 649 KB Posted

Attached to
Rosebud Quarters Fencing Federal contract opportunity
Solicitation number
75H70126Q00019
Issued by
Department of Health and Human Services Indian Health Service

About this file

This document contains technical specification sheets for chain-link fencing details prepared for the Indian Health Service (IHS). The drawings illustrate comprehensive fencing system designs including line fence configurations, double gate assemblies, corner post details, and related structural components.

The specifications detail fence construction requirements with specific material dimensions and measurements. Key components include 2-inch line posts (2.375" minimum outside diameter), 4-inch gate posts (4.00" minimum outside diameter), 1.66-inch outside diameter top rail and tension wire truss bracing, and 3/8-inch truss rods. The fencing system incorporates sliding gate latch mechanisms with detailed component specifications including pipe collars, locking rods, receiver collars, and 1/2-inch by 3.5-inch bolts. Additional details cover fence-mounted lighting assemblies with 1-inch PVC conduit connections to control panels, landscape edging specifications, fabric fastening methods for securing chain-link to line posts, and concrete foundation requirements for post installation. The document references cross-sheet details for chain-link fence specifications, sliding gate latch hardware, and provides front views, top views, and sectional details marked "not to scale" for construction guidance.

View the file

Other files for this federal contract opportunity

Other files attached to Rosebud Quarters Fencing, newest first.
File Type Posted
Amendment 2.pdf PDF
B03 Site Visit Roster.pdf PDF
Amendment 1.pdf PDF
5_APP_B_Fence_Location.pdf PDF
5_APP_A_Bid_Schedule.pdf PDF
5_SOW_GP26RB600Q03_Quarters_Security_Fence.pdf PDF
5_APP_C_02821 Chain Link Fencing(Conc).pdf PDF
Attachment 1 Wage Determination SD20260018.pdf PDF
B01 26Q00019.pdf PDF
Attachment 2 SOW.pdf PDF
Attachment 3 IHS IEE Representation Form.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IN

D

IA

N

HEA LTH SER

V

ICE

1 9 5 5

X X X X

X X X X

X X X X

XXXX

XXXX

XXXX

XXXXXXXXXXXXXX

XXXXXXXXXXXXXX

XXXXXXX

X X X X X X X

X X X X X X X

X X X X X X X

X X X X X X X X

X X X X X X X X

X X X X X X X X

XXXXXXX

10'-0"

12"

6'-0"

2"

3'-6"

TENSION WIRE

2"

LINE POST

(2.375" MIN. O.D.)

VERTICAL ARM ON LINE

POST FOR BARB WIRE

12" DIA.

12'-0"

12"

7'-6"

3'-6"

12" DIA.

6'-0"

GATE POST

(4.00" MIN. O.D)

10'-0"

6'-0"

3'-6"

12" DIA.

3/8" TRUSS

ROD

TRUSS BRACE

(1.66" O.D.)

TENSION WIRE

TRUSS BRACE

(1.66" O.D.)

CORNER POST

(4.00" MIN. O.D.)

6'-0"

2"

3/8" TRUSS

ROD

SEE SHEET-X FOR SLIDING

GATE LATCH DETAILS

** SEE SHEET-X FOR CHAIN-LINK

FENCE DETAILS

GATE POST

(4.00" MIN. O.D)

TOP RAIL

(1.66" O.D.)

TOP RAIL

(1.66" O.D.)

2"

18"

LINE FENCE DETAIL

NOT TO SCALE

DOUBLE GATE DETAIL

NOT TO SCALE

LINE FENCE W/CORNER POST DETAIL

NOT TO SCALE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

INIT.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

LAYOUT NAME:

AutoCAD SHX Text

OFFICE OF ENVIRONMENTAL

AutoCAD SHX Text

SANITATION FACILITIES CONSTRUCTION

AutoCAD SHX Text

HEALTH & ENGINEERING

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

PROJ ENG:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

GREAT PLAIN INDIAN HEALTH SERVICE

AutoCAD SHX Text

115 4TH AVE SE; FEDERAL BUILDING RM 309 ABERDEEN, SD 57401 (605) 226-7451

AutoCAD SHX Text

M-11_CHAIN_LINK_FNCING

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

C. SNELL

AutoCAD SHX Text

AutoCAD SHX Text

M-11_CHAIN LINK FENCING DETAILS

AutoCAD SHX Text

AutoCAD SHX Text

IN

D

IA

N

HEA LTH SER

V

ICE

1 9 5 5

LANDSCAPE EDGING DETAIL

NOT TO SCALE

"L-SHAPED" ALUMINUM

MAINTENANCE STRIP, 3-1/2" CRUSHED

ROCK

3" OF 3/8" - 1/2" CRUSHED

ROCK

10 MIL POLY SHEETING

12" ALUMINUM STAKE, 6 PER

16' SECTION OF EDGING STRIP

BACK FILL MATERIAL

(EXISTING ON SITE)

SLIDE BAR FRONT VIEW

SLIDE BAR TOP VIEW

TOP VIEW OF ASSEMBLY POSITION

FRONT VIEW

TOP VIEW

LOCKING ROD

RECEIVING COLLAR

PIPE COLLAR

LATCH COLLAR

PIPE SPACERS

A

A

4"

4"

1'-7"

4'-2"

3/4"

VIEW

A-A

4'-2"

1" 2-5/8"

5-3/8"

2" 2"

TERMINAL POST WITH FABRIC FASTENING

TRUSS BRACE & TRUSS ROD

LINE POST SET IN

CONCRETE

METHOD OF FASTENING

FABRIC TO LINE POSTS

PLAN VIEW OF CORNER

TERMINAL

POST CAP

TERMINAL POST

TRUSS BRACE

TENSION

STRAP

TURNBUCKLE

TRUSS ROD

EARTH

CONCRETE

LINE POST

TRUSS ROD

TRUSS BRACE

CORNER POST

CONCRETE FOOTING

12" DIAMETER MIN.

LINE POST

CONCRETE

WIRE CLIP

WIRE CLIP

LATCH COLLAR PIPE COLLAR SLIDE BAR

3/4" LOCKING

ROD

RECEIVER

COLLAR

SLIDE BAR

PIPE COLLAR

3/4" LOCKING

ROD

3/4" ROD

1/2" X 3-1/2" BOLTS

2-1/2" X 5" X 3/16"

RECT. TUBE

1/2" X 3-1/2" BOLTS

2-3/8" O.D. PIPE

1/2" X 3-1/2" BOLTS

2-3/8" O.D. PIPE

1-7/8" O.D. PIPE

1-7/8" O.D. PIPE

RECEIVER

COLLAR

LATCH COLLAR

PIPE COLLAR

1/2" ELASTIC NUTS

12"

3'-6"

12"

3'-6"

10'-9" MIN.

3"

4"

3"

4"

2'-1 3/4"

2'-1 3/4"

7"

8"

SLIDING GATE LATCH DETAIL

NOT TO SCALE

CHAIN-LINK FENCE DETAILS

NOT TO SCALE

4'

12"

6'

5'

12"

X X X

X X X

X X X

FORK LATCH

SINGLE GATE DETAIL

NOT TO SCALE

XXXX

XXXX

XXXX

XXX

XXX

XXX

NOTE: FACE LIGHT TOWARDS CONTROL PANEL

1" PVC CONDUIT

TO CONTROL PANEL

FLOOD LIGHT WITH POLE

TOP MOUNTING BRACKET

VERTICAL ARM ON LINE

POST FOR BARBED WIRE

12"

6'

12"

FENCE MOUNTED LIGHT DETAIL

NOT TO SCALE

3'-6"

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

INIT.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

LAYOUT NAME:

AutoCAD SHX Text

OFFICE OF ENVIRONMENTAL

AutoCAD SHX Text

SANITATION FACILITIES CONSTRUCTION

AutoCAD SHX Text

HEALTH & ENGINEERING

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

PROJ ENG:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

GREAT PLAIN INDIAN HEALTH SERVICE

AutoCAD SHX Text

115 4TH AVE SE; FEDERAL BUILDING RM 309 ABERDEEN, SD 57401 (605) 226-7451

AutoCAD SHX Text

M-11_CHAIN_LINK_FNCING

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

AutoCAD SHX Text

C. SNELL

AutoCAD SHX Text

C. SNELL

AutoCAD SHX Text

AutoCAD SHX Text

M-11_CHAIN LINK FENCING DETAILS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

Sheets and Views
M-11_CHAIN_LINK_FNCING-CHAIN_LINK-1
M-11_CHAIN_LINK_FNCING-CHAIN_LINK-2

File details come from the government source that posted it. Updated .