Martin Clinic.pdf
PDF 4 MB Posted
- Attached to
- Life Safety Updates at Kyle, Wanblee, LaCreek
- Solicitation number
- 75H70125R00052
About this file
This document is a detailed architectural and engineering design set for the LaCreek District Clinic Building Project located in Martin, South Dakota. The comprehensive plan covers a single-story medical facility for the Wild Horse Butte CDC, with extensive blueprints including floor plans, elevations, structural details, mechanical systems, electrical layouts, plumbing configurations, and accessibility designs. The drawings are prepared by multiple engineering firms including Henriksen, Inc., and provide a complete technical blueprint for constructing a modern healthcare facility with various specialized rooms such as exam rooms, utility spaces, administrative areas, a pharmacy, patient registration, and supporting infrastructure spaces. The design incorporates specific technical specifications for construction materials, structural elements, building systems, and meets detailed architectural and engineering standards for a functional medical clinic.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R
EF
A2.1
A2.1
95' - 2"
/4
10' - 0" 10' - 0" 10' - 0" 10' - 0" 5' - 0"
5'
0"
10' - 0"
5'
0"
10' - 0" 9' - 0" 10' - 0" 5' - 0" 15' - 0" 11' - 0" 7' - 6"
7'
6"
10' - 0"
9' - 0"
PC VITALS
NURSE CONTROL
MHP EXAM 1
MHP EXAM 2
PC EXAM 1
PC EXAM 2
PC EXAM 3
PC EXAM 4
UNIT SUPPLY
PH NURSE OFFICE
SSC EXAM 1
21 SSC EXAM 2
CLEAN UTILITY
SOILED UTILITY
OP OFFICE 1
SUPPLY/STORAGE
ALCOVE
OP OFFICE 2
HOUSEKEEPING
EXAM ROOM
MECHANICAL
OPP CLERK
3'
8"
WAITING ROOM
7'
6"
7' - 6" 7' - 6 11/16"
7'
6"
BREAKROOM
10' - 0"
PARMACY DIAG
DISPENSE
PHARMACY
DISPENSE
DISPENSING
WORKROOM
ACCREDITED
RECORDS
TECHNICIAN
6'
3/
4"
10' - 8"
PATIENT
REGISTRATION
LAB COMBINED
MODULE
7'
6"
7' - 6"
STORAGE
10' - 3 13/16"10' - 0"
CORRIDOR
HEALTH BENIFITS
COORDINATOR
PATIENT
ACCOUNTS &
BILLING
UNISEX RR
UNISEX RR
SPECIMEN RR
UNISEX RR
UNISEX RR
/4
DUP EQIP SUPPLY
& FILING
10' - 0"
" COMPUTER
WORKROOM
DUP EQ & SUPPLY
16a17a 15a 13a 11a 9a 7a 5a
1b
3a 2a
6a8a 4a
37a
14a
26a 28a
25a22a 27a 29a 31a 33a 35a
34a
38a
40a
37b
32a30a
1a
100a
300a
23a
15' - 0 9/16"
A3.3 3
A3.37
A3.3 2
A3.3
A3.36
A3.31
5' - 0"
10' - 0" 9' - 0"
39a
10a
19a 18a
20a21a
A3.4
3'
3/
4"
2' - 0"
CORRIDOR
CORRIDOR
4' - 5 1/4"8' - 0"
10' - 0"
12' - 3 15/16"
29b STORAGE 29A
A3.4 3 A3.42
A3.4
A3.4
A A C
A
A
B
B
AAAAAAA
A
A
A
39b
36a
SEMI RECESSED
FIRE EXTINGUISHER
SEMI RECESSED
FIRE EXTINGUISHER
BABY CHANGING
STATION
BABY CHANGING
STATION
A3.3 8
A3.3 9
A4.1
A4.1
A4.1 5
A4.1
A4.1
Pr oj ec t N o.
D w g.
N am e
D ra w n
B y
C he ck ed B y
D at e
C op yr ig ht c
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
FL
O
O R
P
LA
N
A1.1
1/4" = 1'-0"1 Level 1
A2.1
A2.1
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
C
EI
LI
N
G P
LA
N
A1.2
A2.1
A2.1
RIDGE VENT
3" INTAKE/EXHAUST
THRU ROOF
3" VENT THRU ROOF
6" EXHAUST FAN VENT
THRU ROOF
8" VENT THRU ROOF
6" EXHAUST FAN VENT
THRU ROOF
6" EXHAUST FAN VENT
THRU ROOF
3" VENT THRU ROOF
6" EXHAUST FAN VENT
THRU ROOF
3" VENT THRU ROOF
6" EXHAUST FAN VENT
THRU ROOF
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
R O
O F
PL
A
N
A1.3 1/4" = 1'-0"1 Roof
Level 1 0' - 0"
ROOF
10' - 0"
A2.1
A4.1
RIDGE VENT
2" POLYSTYRENE
Level 1 0' - 0"
ROOF
10' - 0"
A2.1
2" POLYSTYRENE
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
SE
C
TI
O
N S
A2.1
1/4" = 1'-0"1 Section 1
1/4" = 1'-0"2 Section 2
ROOF
10' - 0"
A2.1
B B A A
1a
RIDGE VENT
4"
12"
Level 1 0' - 0"
ROOF
10' - 0"
A2.1RIDGE VENT
39a
C A A
ASPHALT SHINGLES
SEE SPEC
FURNACE WALL CAP
DOWNSPOUT
CONCRETE SPLASH BLOCK
SEE CIVIL FOR DETAILS
DOWNSPOUT
CONCRETE SPLASH BLOCK
SEE CIVIL FOR DETAILS
GUTTER
HARDIE BOARD LAP SIDING
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
EX
TE
R
IO
R E
LE
VA
TI
O
NS
A3.1 1/4" = 1'-0"1 East Elevation
1/4" = 1'-0"2 North Elevation
ROOF
10' - 0"
A2.1RIDGE VENT
A A A A A A A
DOWNSPOUT
CONCRETE SPLASH BLOCK
SEE CIVIL FOR DETAILS
ASPHALT SHINGLE
SEE SPEC
DOWNSPOUT
CONCRETE SPLASH BLOCK
SEE CIVIL FOR DETAILS
GUTTER
HARDIE BOARD LAP SIDING
Level 1 0' - 0"
ROOF
10' - 0"
A2.1
A
300a
A A
100a
RIDGE VENT
4"
12"
ASPHALT SHINGLE
SEE SPEC
GUTTER
DOWNSPOUT
HARDIE BOARD LAP SIDING
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
EX
TE
R
IO
R E
LE
VA
TI
O
NS
A3.2
1/4" = 1'-0"1 South Elevation
1/4" = 1'-0"2 West Elevation
ROOF
10' - 0"
2'
6" 1'
6"
3'
0"
3' - 0" 4' - 0"
3' - 0" 4' - 0"
Level 1 0' - 0"
ROOF
10' - 0"
3'
0"
4' - 0" 2' - 0" 4' - 0"
Level 1 0' - 0"
ROOF
10' - 0"
2'
6" 1'
6"
3'
0"
2' - 6" 2' - 6"
2' - 6" 2' - 6"
PAPER TOWEL
DISPENSER
SOAP DISPENSER
Level 1 0' - 0"
ROOF
10' - 0"
2'
6" 1'
6"
3'
0"
3' - 0"
1' - 6"3' - 0"2' - 0"4' - 0"
PAPER TOWEL
DISPENSER
SOAP DISPENSER
Level 1 0' - 0"
ROOF
10' - 0"
3'
0"
3'
0" 1'
6"
2'
6"
3' - 0"2' - 0" 6' - 0"
3' - 0"3' - 0"3' - 0"2' - 0"4' - 0"
PAPER TOWEL
DISPENSER
SOAP DISPENSER SPECIMIN PASS THRU
DOOR INTER DYNE
SYSTEMS MODEL 0515
Level 1 0' - 0"
ROOF
10' - 0"
3'
0" 1'
6"
2'
6"
3' - 6" 2' - 6"
3' - 6" 2' - 6"
PAPER TOWEL
DISPENSER
SOAP DISPENSER
Level 1 0' - 0"
ROOF
10' - 0"
3'
0"
PAPER TOWEL
DISPENSER
SOAP DISPENSER
4' - 0" 2' - 0" 4' - 0"
Level 1 0' - 0"
ROOF
10' - 0"
2'
/2
2'
1/
2"
3'
1/
2"
Level 1 0' - 0"
ROOF
10' - 0"
2'
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
IN
TE
R
IO
R E
LE
VA
TI
O
N S
A3.3
3/8" = 1'-0"1 BREAKROOM ELEVATION
3/8" = 1'-0"2 CLEAN UTILITY ELEVATION
3/8" = 1'-0"3 EXAM ROOM ELEVATION TYP.
3/8" = 1'-0"4 COMBINED LAB ELEVATION CLEAN SIDE
3/8" = 1'-0"5 COMBINED LAB ELEVATION DIRTY SIDE
3/8" = 1'-0"6 MINOR PROCEDURE ROOM ELEVATION
3/8" = 1'-0"7 SOILED UTILITY ELEVATION 3/8" = 1'-0"8 PATIENT REGISTRATION DESK
3/8" = 1'-0"9 PHARMACY COUNTER
ROOF
10' - 0"
SEE ADA GRAPHICS
SHEET FOR ALL
MOUNTING HEIGHTS
SPECIMIN PASS THRU
DOOR INTER DYNE
SYSTEMS MODEL 0515
PAPER TOWEL/TRASH
SEMI-RECESSED
SOAP DISPENSER
TOILET PAPER ROLL
FEMININE NAPKIN
DISPOSAL
ADA PIPE PROTECTION
24x36 MIRROR
Level 1 0' - 0"
ROOF
10' - 0"
SEE ADA GRAPHICS
SHEET FOR ALL
MOUNTING HEIGHTS
PAPER TOWEL/TRASH
SEMI-RECESSED
SOAP DISPENSER
TOILET PAPER ROLL
FEMININE NAPKIN
DISPOSAL
ADA PIPE PROTECTION
24x36 MIRROR
Level 1 0' - 0"
ROOF
10' - 0"
SEE ADA GRAPHICS
SHEET FOR ALL
MOUNTING HEIGHTS
TOILET PAPER ROLL
FEMININE NAPKIN
DISPOSAL
PAPER TOWEL/TRASH
SEMI-RECESSED
SOAP DISPENSER
ADA PIPE PROTECTION
24x36 MIRROR
Level 1 0' - 0"
ROOF
10' - 0"
SEE ADA GRAPHICS
SHEET FOR ALL
MOUNTING HEIGHTS
TOILET PAPER ROLL
FEMININE NAPKIN
DISPOSAL
PAPER TOWEL/TRASH
SEMI-RECESSED
SOAP DISPENSER
ADA PIPE PROTECTION
24x36 MIRROR
Level 1 0' - 0"
ROOF
10' - 0"
SEE ADA GRAPHICS
SHEET FOR ALL
MOUNTING HEIGHTS
PAPER TOWEL/TRASH
SEMI-RECESSED
SOAP DISPENSER
TOILET PAPER ROLL
FEMININE NAPKIN
DISPOSAL
ADA PIPE PROTECTION
24x36 MIRROR
Level 1 0' - 0"
ROOF
10' - 0"
SEE ADA GRAPHICS
SHEET FOR ALL
MOUNTING HEIGHTS
URINAL
PAPER TOWEL/TRASH
SEMI-RECESSED
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
R
ES
TR
O
O M
E
LE
VA
TI
O N
S
A3.4
3/8" = 1'-0"1 SPECIMEN RR ELEV A
3/8" = 1'-0"2 ROOM #2 ELEV
3/8" = 1'-0"3 ROOM #3 ELEV
3/8" = 1'-0"4 ROOM #38 ELEV
3/8" = 1'-0"5 ROOM #40 ELEV
3/8" = 1'-0"6 SPECIMEN RR ELEV B
5/8" 3 1/2" 1/2" 5/8"
5/8" FIRE RATED GYP. BOARD
RESILIANT CHANNEL 24" O.C.
3" MINERAL FIBER 2.0-2.3 LBS/FT3
GA FILE NO.WP3241
5/8" FIRE RATED GYP. BOARD
HEADER TO BE 3-2x12
W/ CONTINOUS PLYWOOD
IN BETWEEN GLUED AND
SCREWED
2x6
HEADER TO BE 3-2x12
W/ CONTINOUS 3/4" PLYWOOD
IN BETWEEN GLUED AND
SCREWED
ROOF
10' - 0"
TRUSS
R-45 INSULATION
INSULATION AIR VENT
2-5/8" TYPE X GYP. BD
ATTACHED TO BOTTOM
OF TRUSS
ALUM PERFORATED SOFFIT
GUTTER
3"x4" DOWNSPOUT
2x6 STUD WALL W/ R-21
INSULATION
1" TERMAX SHEATHING
HARDIE LAP SIDING
5/8" TYPE X PAINTED GYP BD
8 MIL VAPOR BARRER
BUILDING WRAP
ASPHALT SHINGLE
SYNTHETIC UNDERLAYMENT
ICE AND WATER SHIELD AT
RIDGE, EVE AND ALL PENETRATIONS
1/2" NOMINAL ROOF SHEATHING
5/8" GYP BD
2-2x6 W/ 1/2" PLYWOOD
CONTINOUS IN BETWEEN
RESILIANT CHANNEL
DOOR FRAME
HARDIE BOARD LAP SIDING
BUILDING WRAP
1" THERMAX SHEATHING
5/8" PAINTED TYPE X GYP BD
8 MIL VAPOR BARRIER
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
D
ET
A
IL
S
A4.1
6" = 1'-0"1 INTERIOR WALL SECTION
1 1/2" = 1'-0"2
EXTERIOR DOOR AND WINDOW JAMB
DETAIL
1 1/2" = 1'-0"3 EXTERIOR DOOR AND WINDOW HEADER
3/4" = 1'-0"4 EVE DETAIL
3" = 1'-0"5 INTERIOR DOOR HEADER
1" = 1'-0"6 WINDOW HEAD AND SILL DETAILS
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
LA
C
R
EE
K D
IS
T
M
ED
C
LI
N
IC
TE
N
LH
H
5/
/2
Door Schedule
Mark Height Width Door Type Frame Material Hardware
Group
1a 7' - 0" 6' - 0" ALUMINUM ALUMINUM 1 1b 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 2 2a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 3 3a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 3 4a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 4 5a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 5 6a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 6 7a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 5 8a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 6 9a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 5 10a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 3 11a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 6 13a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 14a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 15a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 16a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 17a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 18a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 19a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 20a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 21a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 22a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 5 23a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 8 25a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 5 26a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 9 27a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 6 28a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 9 29a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 7 29b 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 6 30a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 10 31a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 6 32a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 5 33a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 5 34a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 11 35a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 6 36a 7' - 0" 6' - 0" N/A HOLLOW METAL N/A 37a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 5 37b 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 11 38a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 3 39a 7' - 0" 3' - 0" HOLLOW METAL HOLLOW METAL 8 39b 7' - 0" 3' - 0" N/A HOLLOW METAL N/A 40a 7' - 0" 3' - 0" SC WOOD PL FACE HOLLOW METAL 3 100a 7' - 0" 3' - 0" HOLLOW METAL HOLLOW METAL 8 300a 7' - 0" 3' - 0" HOLLOW METAL HOLLOW METAL 8
Room Schedule
Number Name Floor Finish Base Finish Wall Finish
Ceiling Finish Perimeter Area
1 WAITING ROOM CARPET TILE 4" VINYL GB-P GB-P 66' - 7 7/8" 241 SF
2 UNISEX RR LINOLEUM 2mm 4" VINYL GB-P/FRP WAINSCOT GB-P 30' - 1 3/8" 57 SF 3 UNISEX RR LINOLEUM 2mm 4" VINYL GB-P/FRP WAINSCOT GB-P 30' - 0" 56 SF 4 PATIENT REGISTRATION LINOLEUM 2mm 4" VINYL GB-P GB-P 34' - 5 1/2" 70 SF 5 HEALTH BENIFITS COORDINATOR CARPET TILE 4" VINYL GB-P GB-P 40' - 7 21/32" 103 SF
6 DUP EQIP SUPPLY & FILING VCT 4" VINYL GB-P GB-P 40' - 0" 73 SF
7 PATIENT ACCOUNTS & BILLING CARPET TILE 4" VINYL GB-P GB-P 40' - 0" 100 SF
8 STORAGE VCT 4" VINYL GB-P GB-P 29' - 2 21/32" 53 SF
9 PH NURSE OFFICE CARPET TILE 4" VINYL GB-P GB-P 39' - 1 1/2" 96 SF
10 SPECIMEN RR LINOLEUM 2mm 4" VINYL GB-P/FRP WAINSCOT GB-P 30' - 0" 56 SF
11 UNIT SUPPLY VCT 4" VINYL GB-P GB-P 30' - 0" 50 SF
12 NURSE CONTROL LINOLEUM 2mm 4" VINYL GB-P GB-P 38' - 7 7/8" 93 SF 13 PC EXAM 4 LINOLEUM 2mm 4" VINYL GB-P GB-P 40' - 0" 100 SF 14 PC VITALS LINOLEUM 2mm 4" VINYL GB-P GB-P 38' - 0" 90 SF 15 PC EXAM 3 LINOLEUM 2mm 4" VINYL GB-P GB-P 40' - 0" 100 SF 16 PC EXAM 2 LINOLEUM 2mm 4" VINYL GB-P GB-P 40' - 0" 100 SF 17 PC EXAM 1 LINOLEUM 2mm 4" VINYL GB-P GB-P 40' - 0" 100 SF 18 MHP EXAM 2 LINOLEUM 2mm 4" VINYL GB-P GB-P 40' - 0" 100 SF 19 MHP EXAM 1 LINOLEUM 2mm 4" VINYL GB-P GB-P 40' - 0" 100 SF 20 SSC EXAM 2 LINOLEUM 2mm 4" VINYL GB-P GB-P 40' - 0" 100 SF 21 SSC EXAM 1 LINOLEUM 2mm 4" VINYL GB-P GB-P 40' - 0" 100 SF
22 OP OFFICE 1 CARPET TILE 4" VINYL GB-P GB-P 39' - 11 31/32" 100 SF
23 SUPPLY/STORAGE ALCOVE VCT 4" VINYL GB-P GB-P 25' - 3 31/32" 33 SF
24 OPP CLERK CARPET TILE 4" VINYL GB-P GB-P 30' - 8" 57 SF
25 OP OFFICE 2 CARPET TILE 4" VINYL GB-P GB-P 39' - 11 31/32" 100 SF
26 CLEAN UTILITY VCT 4" VINYL GB-P GB-P 38' - 0" 90 SF
27 HOUSEKEEPING VCT 4" VINYL GB-P GB-P 29' - 11 31/32" 50 SF
28 SOILED UTILITY LINOLEUM 2mm 4" VINYL GB-P GB-P 38' - 0" 90 SF 29 EXAM ROOM LINOLEUM 2mm 4" VINYL GB-P GB-P 49' - 11 31/32" 141 SF
29A STORAGE VCT 4" VINYL GB-P GB-P 10' - 7 15/32" 7 SF
30 LAB COMBINED MODULE LINOLEUM 2mm 4" VINYL GB-P GB-P 55' - 1 5/32" 188 SF
31 MECHANICAL SEALED CONCRETE 4" VINYL GB-P GB-P 41' - 11 31/32" 110 SF
32 COMPUTER WORKROOM CARPET TILE 4" VINYL GB-P GB-P 40' - 0" 100 SF
33 ACCREDITED RECORDS TECHNICIAN CARPET TILE 4" VINYL GB-P GB-P 35' - 11 31/32" 80 SF
34 DISPENSING WORKROOM SEALED CONCRETE 4" VINYL GB-P GB-P 51' - 6 3/8" 166 SF
35 DUP EQ & SUPPLY VCT 4" VINYL GB-P GB-P 28' - 10 1/2" 44 SF
36 PHARMACY DISPENSE CARPET TILE 4" VINYL GB-P GB-P 31' - 3 11/16" 57 SF
37 PARMACY DIAG DISPENSE CARPET TILE 4" VINYL GB-P GB-P 34' - 8 5/16" 73 SF
38 UNISEX RR LINOLEUM 2mm 4" VINYL GB-P/FRP WAINSCOT GB-P 30' - 0" 56 SF 39 BREAKROOM LINOLEUM 2mm 4" VINYL GB-P GB-P 50' - 10 15/32" 154 SF 40 UNISEX RR LINOLEUM 2mm 4" VINYL GB-P/FRP WAINSCOT GB-P 29' - 11 31/32" 56 SF
100 CORRIDOR CARPET TILE 4" VINYL GB-P ACP 160' - 1 5/32" 373 SF
200 CORRIDOR CARPET TILE 4" VINYL GB-P ACP 52' - 7 1/2" 107 SF
300 CORRIDOR CARPET TILE 4" VINYL GB-P ACP 161' - 10 17/32" 378 SF
4548 SF
SC
H
ED
U
LE
S
A5.1
1/2" = 1'-0"1 SC WOOD PL FACE DOOR
1/2" = 1'-0"2 ALUMINUM DOOR AND FRAME
1/2" = 1'-0"3 HM DOOR W/LITE
1/2" = 1'-0"4 WINDOW TYPE A
Window Schedule
Mark Height Width Window Type Glazing Frame Material Hardware Dual Color Frames Remarks
A 4' - 0" 4' - 0" Slider Advanced Low-E Insulating Glass Fiberglass Composite Cam-Action Locks Interior White-Exterior TBD Pella Impervia Sliding Window B 4' - 0" 3' - 0" Slider Advanced Low-E Insulating Glass Fiberglass Composite Cam-Action Locks Interior White-Exterior TBD Pella Impervia Sliding Window C 3' - 6" 3' - 0" Slider Advanced Low-E Insulating Glass Fiberglass Composite Cam-Action Locks Interior White-Exterior TBD Pella Impervia Sliding Window
1/2" = 1'-0"5 WINDOW TYPE B
1/2" = 1'-0"6 WINDOW TYPE C
S2.1
S2.1
2' - 0"
3'
0"
8"
8"
3'
0"
8"
2' - 0"
8"
95' - 2"
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
La C
R
EE
K M
ED
C
LI
N
IC
S
TR
U
C
TU
R A
L
TE
N
NA
B
5/
/2
5/30/14
FO
UN
DA
TI
O N
PL
AN
S1.1
1/4" = 1'-0"1 FOUNDATION LEVEL
S2.1
S2.1
S2.1
DISPENSING WORKROOM
FLOOR TO BE THICKENED
WALL TO WALL SEE DETAIL
ON S2.1
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
La C
R
EE
K M
ED
C
LI
N
IC
S
TR
U
C
TU
R A
L
TE
N
NA
B
5/
/2
5/30/14
BE
AR
IN
G
P
LA
N
S1.2
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
9"
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
La C
R
EE
K M
ED
C
LI
N
IC
S
TR
U
C
TU
R A
L
TE
N
NA
B
5/
/2
5/30/14
TR
U
SS
P
LA
N
S1.3
NOTE:
TRUSS CLIPS USE SIMPSON STRONG-TIE
H10A-2 OR APPROVED EQUAL
1/4" = 1'-0"1 TRUSS PLAN
Level 1 0' - 0"
2' - 0"
10" 10"
1'
0" 4'
0"
/2
/2
/2
/2
#5 REBAR 10" O.C.
#5 REBAR 24" O.C.
#5 REBAR BENT INTO FOOTING
24" O.C.
#5 REBAR HORIZONTAL 10 1/2" O.C.
6"
1'
0"
12" COMPACTED BASE COURSE
UNDER FLOOR SLAB PER
GEOTECHNICAL REPORT
6" BASE COURSE
SCARIFY AND RECOMPACT 3'
BELOW FOOTING 5' EACH WAY
FROM CENTERLINE PER
GEOTECHNICAL REPORT
SCARIFY AND RECOMPACT 3' BELOW
FLOOR SLAB PER GEOTECHNICAL
REPORT
Level 1 0' - 0"
Level 1 0' - 0"
3' - 0"
10 5/8" 10 5/8" 10 5/8"
1'
0" 4'
0"
/2
/2
/2
/2
#5 REBAR 10 5/8" O.C.
#5 REBAR 24"O.C.
#5 REBAR BENT INTO
FOOTING 24" O.C.
#5 REBAR HORIZONTAL
10 1/2" O.C.
6"
6" BASE COURSE
SCARIFY AND RECOMPACT 3'
BELOW FOOTING 5' EACH WAY
FROM CENTERLINE PER
GEOTECHNICAL REPORT
1'
0"
12" COMPACTED BASE COURSE
UNDER FLOOR SLAB PER
GEOTECHNICAL REPORT
SCARIFY AND RECOMPACT 3' BELOW
FLOOR SLAB PER GEOTECHNICAL
REPORT
Level 1 0' - 0"
Level 1 0' - 0"
4000PSI FIBER REINFORCED
CONCRETE
4"
1' - 6"8" 8"
1'
0" 1'
0"
SCARIFY 3' AND
RECOMPACT
Level 1 0' - 0"
Level 1 0' - 0"
4" 1'
0"
6" 1'
0"
4" 1'
0"
8x8 WWM 4000PSI FIBER REINFORCED
CONCRETE
5/8" TYPE X GYP BD
8 MIL VAPOR BARRIER
R-21 BATT INSULATION
1/2" NOM PLYWOOD 4' EACH
WAY FROM ALL CORNERS
1/2" THERMAX INSULATION CHANGES
TO 1" THERMAX AFTER THE PLYWOOD
ENDS AT 4'
Pr oj ec
D w g.
N am e
D ra w n
C he ck ed B y
D
C op yr
R
EV
IS
IO
N S
N O
DA
TE
D
IS
C
R
IP
TI
O
N
P ro fe ss io na l L an d Ar t A ss oc ia te s
C on su lti ng E ng in ee rin g Se rv ic es
La C
R
EE
K D
IS
TR
IC
T
C
LI
N
IC
B U
IL
DI
NG
P
R O
JE
C
T W
IL
D
H O
R
SE
B U
TT
E
C D
C M
AR
TI
N, S
O
UT
H
DA
KO
TA
La C
R
EE
K M
ED
C
LI
N
IC
S
TR
U
C
TU
R A
L
TE
N
NA
B
5/
/2
5/30/14
DE
TA
IL
S
S2.1
3/4" = 1'-0"1 2' FOOTING SECTION
3/4" = 1'-0"2 3' FOOTING SECTION
1" = 1'-0"3 THICKENED SLAB FOR BEARING WALLS
1" = 1'-0"4 THICKENED FLOOR IN PHARMACY
1 1/2" = 1'-0"5 BUILDING CORNER DETAIL
| 1-TITLE SHEET |
| 2-CIVIL |
| 3-ARCHITECTURALS |
| A0.0 ADA DETAILS |
| A0.1 ARCHITECTURAL NOTES |
| A1.1 FLOOR PLAN |
| A1.2 CEILING PLAN |
| A1.3 ROOF PLAN |
| A2.1 SECTIONS |
| A3.1 EXTERIOR ELEVATIONS |
| A3.2 EXTERIOR ELEVATION |
| A3.3 INTERIOR ELEVATION |
| A3.4 RESTROOM ELEVATIONS |
| A4.1 DETAILS |
| A5.1 SCHEDULES |
| 4-STRUCTRUAL |
| S0.1 STRUCTURAL NOTES |
| S1.1 FOUNDATION PLAN |
| S1.2 BEARING PLAN |
| S1.3 TRUSS PLAN |
| S2.1 DETAILS |
| 5-MECHANICAL |
| M1.0 Mechanical Specifications |
| M1.1 Below Grade Plumbing Plan |
| M1.2 Plumbing Plan |
| M1.3 HVAC Plan |
| M1.4 Details |
| M1.5 Schedules |
| 6-ELECTRICAL |
| E1.0 Spec and Site Plan |
| E1.1 Lighting Plan |
| E1.2 Power Plan |
| E1.3 One-Line Diagram |
File details come from the government source that posted it. Updated .