B05 A2-3 Centria-SRS3-Roof-Tech-Data.pdf
PDF 747 KB Posted
- Attached to
- Rosebud Exterior Construction Project Bid Pack 1 Federal contract opportunity
- Solicitation number
- 75H70124R00052
About this file
This document is a Technical Data Sheet for CENTRIA's SRS 3 Structural Standing Seam Roof System. The SRS 3 is a weather-tight, low-slope roofing system designed for both new construction and retrofit projects, offering high performance structural features and aesthetic appeal. Key details include:
The SRS 3 panels are available in galvanized or Galvalume steel, with widths of 12", 16", or 18", and lengths up to 220 feet. They feature a 3-inch nominal panel height, planked stiffening ribs, a mechanically seamed factory side lap, and factory notched and flared end laps. The panels can be installed left-to-right, right-to-left, or from the middle, and can be field roll-formed and curved. Technical specifications are provided for panel coatings, gages, battens, clips, slope requirements, and testing for air leakage, water penetration, wind loads, and impact resistance.
View the file
Other files for this federal contract opportunity
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SRS Structural Standing Seam Roof Systems are designed as true standing seam roof systems which offer high performance structural features while attaining aesthetic lines required in architectural systems. They are designed as a weather tight low-slope system for roofing in both new construction and retrofit, and provide a low maintenance, long-lasting roof for any type of building. The SRS 3 panels employ a separate field applied or factory-caulked continuous batten which provides for installation in both directions. SRS 3 panels are non-directional, which enables them to be installed left to right, right to left, or from the middle of a roof in both directions. When directional finishes are used (Micas, Metallics, etc.) one direction of installation must be held.
DESCRIPTION
GENERAL DESIGN OPTIONS
SRS 3
STANDING SEAM
METAL ROOF PANELS
TECHNICAL DATA SHEET
CENTRIA.COM
Copyright © 2022 CENTRIA, a NUCOR® company. CENTRIA-TDS-SRS3-NJ 11/2022
SRS 3
Galvanized1 (G90) (Standard)
Galvalume 50,000 psi (Optional)
PANEL HEIGHT 3” [76.2mm] NOMINAL 3” [76.2mm] NOMINAL
PANEL WIDTH 12” [305mm], 16” [406mm], 18” [457mm] 12” [305mm], 16” [406mm], 18” [457mm]
PANEL LENGTH
Factory-formed to 48 ft. [14.630m] 48 ft. [14.630m] to 60 ft. [18.288m];
with special transportation permit.
Field-formed up to 220 ft. [67.056m]
Factory-formed to 48 ft. [14.630m] 48 ft. [14.630m] to 60 ft. [18.288m];
with special transportation permit.
Field-formed up to 220 ft. [67.056m]
STIFFENING RIBS Planked Planked
FACTORY SIDE LAP Mechanically seamed Mechanically seamed
FACTORY END LAP Factory notched and flared Factory notched and flared
FACTORY SEALANT Non-curing butyl (2 beads in batten)5 Non-curing butyl (2 beads in batten)5
GAGE
20 [.91mm], 22 [.76mm], 24 [.60mm] (standard) 18 [1.19mm] (optional)
20 [.91mm], 22 [.76mm], 24 [.60mm] (standard) 18 [1.19mm] (optional)
BATTEN2 20 [.91mm], 22 [.76mm], 24 [.60mm] 20 [.91mm], 22 [.76mm], 24 [.60mm]
CLIPS
One-piece (Galvanized or Stainless steel) (standard) Two-piece clips3 (optional)
One-piece (Galvanized or Stainless steel) (standard) Two-piece clips3 (optional)
MINIMUM ROOF SLOPE 1/2”: 12” w/o endlaps 1:12 w/ endlaps
1/2”: 12” w/o endlaps 1:12 w/ endlaps
EXPOSED EXTERIOR 1.0 mil PVDF, 1.6 mil Duragard,
2.4 mil Duragard Plus
1.0 mil PVDF, 1.6 mil Duragard,
2.4 mil Duragard Plus
NON-EXPOSED INTERIOR 0.5 mil primer/backer 0.5 mil primer/backer
SURFACE FINISH Smooth (standard) Embossed (optional)4
Smooth (standard) Embossed (optional)4
1. Alternate base material, panel lengths and gages may also be available. Contact CENTRIA.
2. Battens are the same gage as panel except when panel is 18 [1.19mm] gage, batten must be 20 [.91mm] for 18 [1.19mm] gage panels.
3. Available for aluminum or COE projects.
4. Embossing is non-directional.
5. Field applied webbed mastic tape is optional and is required for weather-tight warranties and field roll formed SRS3.
“Oil Canning” is an inherent part of light gage cold-formed metal products, particularly those with broad flat areas.
CENTRIA takes every precaution, as defined by MCA, to minimize the effects of oil canning. Lack of flatness or waviness due to oil canning is not sufficient cause for rejection of material.
12” PLANKED
18” PLANKED
SEAMED PANEL
• May be installed over a variety of support substrates, including open framing, steel deck, or plywood deck
• Mechanically seamed side joint with a separate continuous batten
• Concealed clip system reduces roof penetrations and includes a built-in standoff to allow for thermal movement
• SRS 3 panels may be erected from left-to-right, right-to-left, or from the middle working both directions
• Field roll forming and curving capabilities allow for longer continuous panel lengths than can be shipped on trucks
SRS 3 ROOF DESIGN FEATURES & BENEFITS
A. For information on special applications, contact your local CENTRIA Sales Representative.
B. Panel length tolerance is ±1/4” [6mm].
NOTES
STANDING SEAM SRS 3 TESTING
TEST CHARACTERISTIC TEST METHOD TEST TITLE RESULTS
ENVIRONMENTAL
AIR LEAKAGE ASTM E 1680 Determines resistance to air leakage 0.036 cfm/sf at 4.0 psf
WATER
PENETRATION ASTM E 1646
Determines resistance to water penetration by uniform static air pressure difference
No penetration at 12.0 psf
STANDING WATER ASTM E 2140
Determines resistance to water penetration when submerged under standing water
No leakage with 8” of standing water for 24 hours
STRUCTURAL
WIND LOADS ASTM E 1592 &
USACOE Uplift Test
Determines structural performance under uniform static air pressure difference
See load span tables
IMPACT RESISTANCE TAS 100, TAS 110,
TAS 125
Determines whether a product used as external protection to maintain a building envelope provides sufficient resistance tot windborne debris
Approved HVHZ; see FL16205
WIND UPLIFT
RATINGS
UL 580 Determines uplift resistance rating of roof assemblies
Class 90 for steel purlins, steel deck, and plywood constructions
FM 4471 Determines uplift resistance rating of roof assemblies
1-90 for steel purlin and steel deck construction, 1-180 for steel purlin construction
File details come from the government source that posted it. Updated .