This solicitation requests proposals for a construction project to remodel pharmacy spaces at the Pine Ridge Hospital in Pine Ridge, South Dakota. The scope of work includes demolishing and replacing the existing inpatient and outpatient pharmacy areas while keeping both pharmacies operational throughout construction. The project magnitude is estimated between $1,000,000 and $5,000,000. The contract will be a firm fixed price awarded after a lowest price technically acceptable evaluation of proposals received by August 15, 2022. As a 100% small business set-aside for NAICS code 236220, the successful offeror must have an average annual revenue less than $39.5 million. The one year period of performance begins with notice to proceed anticipated in late 2022. The Indian Health Service seeks a qualified contractor to complete the pharmacy remodel while minimizing pharmacy downtime.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PINE RIDGE USP 795,797,800 PHARMACY RENOVATION
HFG Architecture © 2022
HOLLOW METAL DOORS AND
FRAMES
08 11 13 - 1
SECTION 08 11 13
HOLLOW METAL DOORS AND FRAMES
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Non-fire-rated hollow metal doors and frames.
B. Hollow metal frames for wood doors.
C. Stainless-steel hollow metal doors and frames.
1.02 RELATED REQUIREMENTS
A. Section 08 71 00 - Door Hardware.
B. Section 08 80 00 - Glazing: Glass for doors and borrowed lites.
1.03 REFERENCE STANDARDS
A. ADA Standards - Americans with Disabilities Act (ADA) Standards for Accessible Design; 2010.
B. ANSI/SDI A250.8 - Specifications for Standard Steel Doors and Frames (SDI-100); 2017.
C. ANSI/SDI A250.10 - Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and Frames; 2011.
D. ASTM A480/A480M - Standard Specification for General Requirements for Flat-Rolled Stainless and Heat-Resisting Steel Plate, Sheet, and Strip; 2018a.
E. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or
Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 2018.
F. ASTM A666 - Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel
Sheet, Strip, Plate, and Flat Bar; 2015.
G. ASTM A1008/A1008M - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable; 2018.
H. ASTM A1011/A1011M - Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength; 2018a.
I. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;
2018b.
J. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2017.
K. NAAMM HMMA 840 - Guide Specifications for Installation and Storage of Hollow Metal Doors and Frames; 2007.
L. NAAMM HMMA 866 - Guide Specifications for Stainless Steel Hollow Metal Doors and Frames;
2012.
1.04 SUBMITTALS
A. Product Data: Materials and details of design and construction, hardware locations, reinforcement type and locations, anchorage and fastening methods, and finishes.
1.05 DELIVERY, STORAGE, AND HANDLING
A. Comply with NAAMM HMMA 840 or ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.
B. Protect with resilient packaging; avoid humidity build-up under coverings; prevent corrosion and adverse effects on factory applied painted finish.
HOLLOW METAL DOORS AND
FRAMES
08 11 13 - 2
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Hollow Metal Door Frames:
1. Ceco Door, an Assa Abloy Group company: www.assaabloydss.com/#sle.
2. Curries, an Assa Abloy Group company: www.assaabloydss.com/#sle.
3. Mesker, dormakaba Group; FDJ Series Drywall Frames:
www.meskeropeningsgroup.com/#sle.
4. Republic Doors, an Allegion brand: www.republicdoor.com/#sle.
5. Steelcraft, an Allegion brand: www.allegion.com/#sle.
B. Stainless-Steel Hollow Metal Doors and Frames:
1. Basis of design: Terra Universal; info@TerraUniversal.com
2. Ceco Door, an Assa Abloy Group company: www.assaabloydss.com/#sle.
3. Curries, an Assa Abloy Group company: www.assaabloydss.com/#sle.
4. Steelcraft, an Allegion brand: www.allegion.com/#sle.
5. Substitutions: See Section 01 60 00 - Product Requirements.
2.02 PERFORMANCE REQUIREMENTS
A. Requirements for Hollow Metal Doors and Frames:
1. Steel Sheet: Comply with one or more of the following requirements; galvannealed steel complying with ASTM A653/A653M, cold-rolled steel complying with ASTM A1008/A1008M, or hot-rolled pickled and oiled (HRPO) steel complying with ASTM A1011/A1011M, commercial steel (CS) Type B, for each.
2. Accessibility: Comply with ICC A117.1 and ADA Standards.
3. Exterior Door Top Closures: Flush end closure channel, with top and door faces aligned.
4. Door Edge Profile: Manufacturers standard for application indicated.
5. Typical Door Face Sheets: Flush.
6. Glazed Lights: .
a. Stainless Steel: Flush mount, dual pane with rounded corners
2.03 HOLLOW METAL DOORS
A. Stainless-Steel Interior Doors:
1. Basis for design: Terra Universal, CleanSeam 316L 1999-89 pre-hung with automatic operator.
2. Applications: Comply with designated application in accordance with NAAMM HMMA 866 guidelines.
a. Highly corrosive.
b. Clean room.
3. Door Face Sheets: Stainless-steel, Type 316 alloy in compliance with ASTM A666.
a. Sheet Thickness: 16 gauge, 0.053 inch, minimum.
b. Door Finish: No.4 - Brushed satin finish in accordance with ASTM A480/A480M.
4. Door Core Material: Polystyrene, 1 lbs/cu ft minimum density.
a. Foam Plastic Insulation: Manufacturer's standard board insulation with maximum flame spread index (FSI) of 75, and maximum smoke developed index (SDI) of 450 in accordance with ASTM E84, and completely enclosed within interior of door.
2.04 HOLLOW METAL FRAMES
A. Comply with standards and/or custom guidelines as indicated for corresponding door in accordance with applicable door frame requirements.
B. Interior Door Frames, Non-Fire Rated: Face welded type.
1. Terminated Stops: Provide at interior doors; closed end stop terminated 6 inch, maximum, above floor at 45 degree angle.
2. Frame Metal Thickness: 16 gage, 0.053 inch, minimum.
https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1008/A1008M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M https://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20A1011/A1011M
HOLLOW METAL DOORS AND
FRAMES
08 11 13 - 3
3. Frame Finish: Factory primed and field finished.
C. Door Frames, Fire-Rated: Face welded type.
1. Fire Rating: Same as door or as required on drawings, labeled.
2. Terminated Stops: Provide at interior doors; closed end stop terminated 6 inch, maximum, above floor at 45 degree angle.
3. Frame Metal Thickness: 16 gauge, 0.053 inch, minimum.
4. Frame Finish: Factory primed and field finished.
D. Stainless-Steel Door Frames: Provide full profile and continuously welded type in compliance with NAAMM HMMA 866, with Type 316 alloy in compliance with ASTM A666.
E. Frames for Wood Doors: Comply with frame requirements in accordance with corresponding door.
2.05 FINISHES
A. Primer: Rust-inhibiting, complying with ANSI/SDI A250.10, door manufacturer's standard.
2.06 ACCESSORIES
A. Glazing: As specified in Section 08 80 00, factory installed.
B. Perimeter gasket C. Automatic sweep with drop-down gasket D. Automatic operator with 12 programmable options
1. Hand wave sensors both sides E. Silencers: Resilient rubber, fitted into drilled hole; provide three on strike side of single door, three on center mullion of pairs, and two on head of pairs without center mullions.
PART 3 EXECUTION
3.01 INSTALLATION
A. Install doors and frames in accordance with manufacturer's instructions and related requirements of specified door and frame standards or custom guidelines indicated.
B. Coordinate frame anchor placement with wall construction.
C. Install door hardware as specified in Section 08 71 00.
3.02 ADJUSTING
A. Adjust for smooth and balanced door movement.
END OF SECTION
HOLLOW METAL DOORS AND
FRAMES
08 11 13 - 4
File details come from the government source that posted it. Updated .