A523 - EXTERIOR DETAILS.pdf

PDF 653 KB Posted

Attached to
75H701-20-Q-00014, Pharmacy Windows at Fort Yuma Health Care Center
Solicitation number
75H701-20-Q-00014
Issued by

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

07 95 00.05

08 44 23.17

08 80 00.10

08 44 23.01

08 41 13.24

07 71 13.10

07 54 23.02

07 21 00.09

7 100

TOP

08 41 13.24

07 54 23.02

07 54 23.27

5 200

TO PARAPET

08 44 23.01

08 80 00.10

07 71 13.01

05 12 00.01

05 12 00.02

05 12 00.02

08 41 13.01

08 80 00.10

07 21 00.09

07 62 00.05

07 54 23.01

05 31 00.01

07 24 00.01

07 54 23.02

08 41 13.43

07 54 23.28

07 54 23.28

07 54 23.15

07 54 23.27

07 62 00.03

07 54 23.02

07 54 23.01

07 24 00.18

07 92 00.01

07 24 00.18

07 92 00.01

07 24 00.01

07 54 23.22

12 21 23.02

07 21 00.09

09 22 16.09

09 29 00.21

07 54 23.01

07 54 23.02

07 54 23.29

07 41 13.31

07 54 23.27

07 54 23.15

09 22 16.01

05 31 00.02

09 22 16.09

09 29 00.21

07 71 13.01

07 54 23.27

06 16 43.01

05 41 00.01

05 50 00.23

09 22 16.07

05 50 00.27

09 22 16.01

05 50 00.27

07 41 13.31

05 41 00.12

05 41 00.01

07 21 00.11

05 50 00.27

07 71 13.10

09 22 16.01

06 10 00.02

07 62 00.09

07 54 23.28

05 41 00.12

7 000

TOP

07 54 23.27

07 54 23.27

07 54 23.28

07 54 23.15

05 41 00.01

07 21 00.10

07 54 23.16

07 54 23.02

06 16 43.01

07 24 00.45

REFERENCE KEYNOTES

C2

HEAD DETAIL

1:5

A1 A322

B2

JAMB DETAIL

1:5

A1 A322

225 300 325

07 62 00.05

07 42 43.01

07 27 26.01

06 16 43.01

07 21 00.09

04 25 05.01

04 25 05.05

07 21 00.09

05 41 00.01

TOP OF ROOF

D2

SCUPPER DETAIL

1:5

A103 A523

07 92 00.01

07 24 00.18

07 24 00.01

07 24 00.45

06 16 43.01

07 24 00.01

06 16 43.01

07 24 00.18

07 92 00.01

07 54 23.02

07 71 13.01

07 54 23.27

07 54 23.28

07 54 23.01

07 62 00.08

05 41 00.01

07 54 23.28

07 54 23.33

08 41 13.01

08 80 00.10

07 54 23.02

07 54 23.27

07 92 00.01

09 29 00.21

5 200

TOP OF PARAPET

05 12 00.01

07 54 23.28

07 54 23.15

05 31 00.01

SEE D4/A521

FOR SEISMIC

JOINT DETAIL

08 41 13.46

07 54 23.02

SEE D4/A521

FOR SEISMIC

JOINT DETAIL

A3 ROOF @ LIGHT MONITOR

1:5A4 A323

A4 ROOF @ LIGHT MONITOR

1:5A4 A323

A5 EXPANSION JOINT

1:5A3 A322

C3 ROOF @ LIGHT MONITOR

1:5A4 A323

C4 HEAD @ LIGHT MONITOR

1:5A4 A323

B4 SILL @ LIGHT MONITOR

1:5A4 A323

B5 EXPANSION JOINT

1:5A4 A322

D5 PARAPET BASE

1:5C1 A323

E5 PARAPET

1:5C1 A323

E4 SCUPPER

1:5C1 A323

E3 PARAPET @ LIGHT MONITOR

1:5A4 A323

05 41 00.01

05 12 00.01

05 12 00.02

09 22 16.09

05 41 00.19

05 41 00.02

05 41 00.01

05 41 00.01

05 41 00.01 07 21 00.09

07 21 00.11

07 21 00.13

05 41 00.20

07 71 13.02

07 71 13.03

07 27 26.02

08 41 13.01

08 41 13.01

07 92 00.01

05 12 11.19

07 54 23.25

22 00 00.01

07 54 23.27

07 54 23.02

05 41 00.20

07 71 13.02

05 41 00.01

05 12 00.01

05 41 00.23

SEE WALL

SECTIONS FOR

FINISH THIS

SURFACE.

OVER

07 54 23.01

07 54 23.27

WHERE

INDICATED

07 24 00.45

07 24 00.45

07 24 00.45

07 24 00.01

07 24 00.01

07 24 00.45

A1 CRICKET AT METAL ROOF

1:5A1 A322

06 10 00.02

07 54 23.36

07 54 23.36

05 41 00.25

07 24 00.18

05 41 00.25

07 41 13.01

07 41 13.06

07 41 13.33

07 41 13.14

07 41 13.14

07 62 00.17

07 42 43.01

07 41 13.35

07 41 13.06

05 31 00.01

07 41 13.13

07 41 13.31

04 25 05.01 - RAMMED EARTH WALL WITH FIELD APPLIED SEALANT

04 25 05.05 - PLYWOOD FORM; 25

05 12 00.01 - STEEL BEAM

05 12 00.02 - STEEL COLUMN

05 12 11.19 - STEEL CHANNEL

05 31 00.01 - STEEL ROOF DECK

05 31 00.02 - STEEL FLOOR DECK; SEE STRUCTURAL

05 41 00.01 - STEEL STUD; 152

05 41 00.02 - STEEL TRACK

05 41 00.12 - STEEL STUD; 200

05 41 00.19 - STEEL TRACK 152 OPEN END ATTACHED OVER

FLANGE OF W SHAPE

05 41 00.20 - 1.092 mm HAT CHANNEL - 2 PER COPING ANCHOR CLIP

05 41 00.23 - STEEL TRACK 152 - OPEN END ATTACHED OVER HSS -

USE WHEN HSS IS LESS THAN 152

05 41 00.25 - CONTINUOUS FLAT STRAP BACKING; 150 WIDE, 1.372

THICK

05 50 00.23 - 10mm STEEL PLATE

05 50 00.27 - CONTINUOUS PLATE - SEE STRUCTURAL

06 10 00.02 - CONTINUOUS PRESSURE TREATED WOOD BLOCKING

06 16 43.01 - GLASS-MAT GYPSUM SHEATHING BOARD

07 21 00.09 - GLASS FIBER BLANKET INSULATION- R13

07 21 00.10 - GLASS FIBER BLANKET INSULATION- R30

07 21 00.11 - SPRAY POLYURETHANE FOAM INSULATION IN BOXED

HEADER

07 21 00.13 - SPRAY POLYURETHANE FOAM INSULATION IN JAMB /

HEADER

07 24 00.01 - 50 EXTERIOR INSULATION AND FINISH SYSTEM

07 24 00.18 - STARTER TRACK

07 24 00.45 - FLUID APPLIED VAPOR PERMEABLE AIR/WATER

RESISTIVE BARRIER

07 27 26.01 - FLUID APPLIED MEMBRANE AIR BARRIER

07 27 26.02 - EXTEND FLUID APPLIED MEMBRANE AIR BARRIER INTO

ROUGH OPENING, TYPICAL

07 41 13.01 - METAL ROOF PANEL SYSTEM

07 41 13.06 - CONTINUOUS CLEAT

07 41 13.13 - ROOF INSULATION WITH BONDED SUBSTRATE BOARD

07 41 13.14 - SELF-ADHERING, POLYETHYLENE-FACED SHEET

07 41 13.31 - GALVANIZED METAL ANGLE, 1.092 THICK

07 41 13.33 - LAP SELF ADHERING SHEET OVER FLASHING AND

UNDER CLEAT

07 41 13.35 - OPENING FLASHING

07 42 43.01 - ALUMINUM COMPOSITE WALL PANEL- DRY JOINT

SYSTEM

07 54 23.01 - THERMOPLASTIC POLYOLEFIN MEMBRANE ROOF

SYSTEM

07 54 23.02 - THERMOPLASTIC POLYOLEFIN MEMBRANE

07 54 23.15 - 13 COVER BOARD

07 54 23.16 - ROOF INSULATION

07 54 23.22 - REGLET AND COUNTER FLASHING

07 54 23.25 - SCUPPER

07 54 23.27 - 16 COVER BOARD

07 54 23.28 - PROVIDE MEMBRANE STRIP, MASTIC AND WELD

ACCORDING TO ROOFING MANUFACTURER'S

RECOMMENDATIONS

07 54 23.29 - SPLICE MEMBRANES ACCORDING TO

MANUFACTURER'S RECOMMENDATIONS

07 54 23.33 - MODIFIED REGLET AND COUNTER FLASHING

07 54 23.36 - TERMINATION BAR

07 62 00.05 - METAL FLASHING

07 62 00.08 - GALVANIZED METAL SCUPPER SLEEVE, 200MM X

200MM X 300 MM DEEP WITH 100MM INTEGRAL

FLASHING

07 62 00.09 - GALVANIZED METAL SLEEVE 200MM X 200MM DEPTH

TO FIT WALL WITH 100MM INTEGRAL FLASHING -

PROVIDE OVERFLOW CAPACITY, SEE ELEVATION

A6/A523

07 62 00.17 - PROVIDE 100 RETURN FLANGE AT BOTH ENDS OF

SHEET METAL CRICKET

07 71 13.01 - MANUFACTURED ROOF COPING

07 71 13.02 - COPING ANCHOR CLIP

07 71 13.03 - CONTINUOUS CLEAT

07 71 13.10 - ALUMINUM FLASHING

07 92 00.01 - BACKER ROD AND SEALANT

07 95 00.05 - EXTERIOR ARCHITECTURAL JOINT SYSTEM -

PREFORMED CELLULAR FOAM

08 41 13.01 - ALUMINUM FRAMED STOREFRONT SYSTEM

08 41 13.24 - ALUMINUM BRAKE METAL TRIM

08 41 13.43 - CONTINUOUS ALUMINUM CLEAT ATTACHMENT AT

DRIP EDGE.

08 41 13.46 - PROTECT ALUMINUM BREAK METAL TRIM FROM

GALVANIC ACTION

08 44 23.01 - STRUCTURAL-SEALANT-GLAZED CURTAIN WALL

SYSTEM

08 44 23.17 - DEAD LOAD ANCHOR

08 80 00.10 - INSULATING GLASS UNITS

09 22 16.01 - GYPSUM BOARD CEILING ON GRID SUSPENSION

SYSTEM

09 22 16.07 - STEEL STUD, 92, - SEE PARTITION TYPES FOR GAUGE

AND SPACING

09 22 16.09 - HAT-SHAPED, RIGID FURRING CHANNEL

09 29 00.21 - GYPSUM WALLBOARD, TYPE-X

12 21 23.02 - MOTORIZED ROLLER SHADE

22 00 00.01 - ROOF DRAIN SYSTEM

100 100

A6 SCUPPER / OVERFLOW

1:5- A523

A523

EXTERIOR DETAILS

AGOYO

PARRILL

REV

ISSUE: 10.15.15 - Submittal 3

PROJECT NO: 08-0110.001

CAD DWG FILE: 08-0110-A523.dwg

DRAWN BY:

CHECKED BY:

SHEET TITLE

DATE DESCRIPTION

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

E

21 3 4 5 6

D

C

B

A

D

C

B

A

21 3 4 5 6

A M

VOLUME 2: Sheet 69 of 111

File details come from the government source that posted it. Updated .