GENERAL SHEET NOTES

REFERENCE KEYNOTES

A. ALL UNITS ARE IN MILLIMETERS UNLESS OTHERWISE

NOTED.

B. FOR OVER EXCAVATION DETAIL REFERENCE TO

SHEET A2/S002

C. PROVIDE CONTROL JOINTS IN CONCRETE CAP AT

2400 OC, REFERENCE TO SHEET E2/S501

TO SLAB

7 350

TO CLERESTORY

5 200

SILL

6 450

HEAD

7 600

TO PARAPET

TO SLAB

7 350

TO CLERESTORY

5 200

SILL

6 450

HEAD

7 600

TO PARAPET

TO SLAB

SILL

2 700

HEAD

7 600

TO PARAPET

03 30 00.13

09 51 23.01

03 30 00.05

08 41 13.01

07 24 00.01

06 16 43.01

07 21 00.09

05 41 00.01

07 71 13.01

08 41 13.01

07 54 23.02

07 54 23.01

09 29 00.06

09 29 00.06

09 29 00.05

05 31 00.01

07 54 23.01

07 24 00.01

07 54 23.22

05 12 00.01

09 29 00.06

09 29 00.05

05 31 00.01

07 54 23.01

05 12 00.01

07 54 23.26

07 54 23.26

TO SLAB

7 350

TO CLERESTORY

7 600

TO PARAPET

07 24 00.01

06 16 43.01

05 41 00.01

07 21 00.09

07 54 23.01

07 71 13.01

TO SLAB

7 600

TO PARAPET

5 200

TO PARAPET

07 24 00.01

06 16 43.01

05 41 00.01

07 21 00.09

07 54 23.01

07 71 13.01

08 41 13.01

07 54 23.02

07 54 23.01

07 62 00.05

07 54 23.22

07 54 23.22

07 24 00.01

07 71 13.01

07 54 23.01

A4

A523

C4

A523

A3

A523

C3

A523

E3

A523

B3

A524

C3

A524

E4

A523

E5

A523

E5

A523

D5

A523

07 54 23.22 07 54 23.22

07 54 23.02

07 54 23.02 07 54 23.01

07 54 23.02 07 54 23.02

C1 SECTION @ LIGHT MONITOR

1:25- A323

A1 SECTION @ ACTIVITIES ROOM

1:25A101B A323

A4 SECTION @ LIGHT MONITOR

1:25A101C A323

07 54 23.02

07 54 23.02

05 12 00.01

SEE

REFLECTED CEILING PLAN

3 500

BOT OF BEAM WRAP

2 700

SOFFIT

3 500

BOT OF BEAM WRAP

07 26 00.01

03 30 00.13

07 26 00.01

07 54 23.27

07 24 00.45

06 16 43.01

05 12 00.01

03 30 00.13

07 26 00.01

09 22 16.01

07 54 23.27

07 54 23.01

07 54 23.27

3 000

FIXTURE

26 00 00.02

B4

A523

05 41 00.01

05 41 00.01

05 41 00.01

05 41 00.01

3 000

FIXTURE

26 00 00.02

26 00 00.02

05 41 00.01

C5

A541

C5

A541

07 54 23.27

7 140

TO STEEL

5 185

TO STEEL

2 700

SOFFIT

23 00 00.08

23 00 00.02

09 51 23.01

23 00 00.02

05 41 00.01

05 41 00.01

05 41 00.01

07 54 23.02

09 29 00.20

09 29 00.20

09 29 00.20

03 30 00.05 - CONTINUOUS BUILDING APRON: 100 THICK, 450 WIDE

1:50 SLOPE

03 30 00.13 - CONCRETE SLAB ON GRADE

05 12 00.01 - STEEL BEAM

05 31 00.01 - STEEL ROOF DECK

05 41 00.01 - STEEL STUD; 152

06 16 43.01 - GLASS-MAT GYPSUM SHEATHING BOARD

07 21 00.09 - GLASS FIBER BLANKET INSULATION- R13

07 24 00.01 - 50 EXTERIOR INSULATION AND FINISH SYSTEM

07 24 00.45 - FLUID APPLIED VAPOR PERMEABLE AIR/WATER

RESISTIVE BARRIER

07 26 00.01 - UNDER-SLAB VAPOR RETARDER - SEE S502 FOR

INSTALLATION DETAILS

07 54 23.01 - THERMOPLASTIC POLYOLEFIN MEMBRANE ROOF

SYSTEM

07 54 23.02 - THERMOPLASTIC POLYOLEFIN MEMBRANE

07 54 23.22 - REGLET AND COUNTER FLASHING

07 54 23.26 - SCUPPER BEYOND

07 54 23.27 - 16 COVER BOARD

07 62 00.05 - METAL FLASHING

07 71 13.01 - MANUFACTURED ROOF COPING

08 41 13.01 - ALUMINUM FRAMED STOREFRONT SYSTEM

09 22 16.01 - GYPSUM BOARD CEILING ON GRID SUSPENSION

SYSTEM

09 29 00.05 - GYPSUM BOARD SOFFIT

09 29 00.06 - GYPSUM BOARD WRAP OVER BEAM. SMOOTH FINISH.

09 29 00.20 - GYPSUM BOARD: LEVEL 5 FINISH

09 51 23.01 - ACOUSTICAL TILE CEILING SYSTEM

23 00 00.02 - MECHANICAL DUCT

23 00 00.08 - DIFFUSER

26 00 00.02 - LIGHT FIXTURE, REFER TO ELECTRICAL

A323

WALL SECTIONS

AGOYO

PARRILL

REV

ISSUE: 10.15.15 - Submittal 3

PROJECT NO: 08-0110.001

CAD DWG FILE: 08-0110-A323.dwg

DRAWN BY:

CHECKED BY:

SHEET TITLE

DATE DESCRIPTION

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

E

21 3 4 5 6

D

C

B

A

D

C

B

A

21 3 4 5 6

A M

VOLUME 2: Sheet 47 of 111