GENERAL SHEET NOTES
REFERENCE KEYNOTES
A. ALL UNITS ARE IN MILLIMETERS UNLESS OTHERWISE
NOTED.
B. FOR OVER EXCAVATION DETAIL REFERENCE TO
SHEET A2/S002
C. PROVIDE CONTROL JOINTS IN CONCRETE CAP AT
2400 OC, REFERENCE TO SHEET E2/S501
TO SLAB
7 350
TO CLERESTORY
5 200
SILL
6 450
HEAD
7 600
TO PARAPET
TO SLAB
7 350
TO CLERESTORY
5 200
SILL
6 450
HEAD
7 600
TO PARAPET
TO SLAB
SILL
2 700
HEAD
7 600
TO PARAPET
03 30 00.13
09 51 23.01
03 30 00.05
08 41 13.01
07 24 00.01
06 16 43.01
07 21 00.09
05 41 00.01
07 71 13.01
08 41 13.01
07 54 23.02
07 54 23.01
09 29 00.06
09 29 00.06
09 29 00.05
05 31 00.01
07 54 23.01
07 24 00.01
07 54 23.22
05 12 00.01
09 29 00.06
09 29 00.05
05 31 00.01
07 54 23.01
05 12 00.01
07 54 23.26
07 54 23.26
TO SLAB
7 350
TO CLERESTORY
7 600
TO PARAPET
07 24 00.01
06 16 43.01
05 41 00.01
07 21 00.09
07 54 23.01
07 71 13.01
TO SLAB
7 600
TO PARAPET
5 200
TO PARAPET
07 24 00.01
06 16 43.01
05 41 00.01
07 21 00.09
07 54 23.01
07 71 13.01
08 41 13.01
07 54 23.02
07 54 23.01
07 62 00.05
07 54 23.22
07 54 23.22
07 24 00.01
07 71 13.01
07 54 23.01
A4
A523
C4
A523
A3
A523
C3
A523
E3
A523
B3
A524
C3
A524
E4
A523
E5
A523
E5
A523
D5
A523
07 54 23.22 07 54 23.22
07 54 23.02
07 54 23.02 07 54 23.01
07 54 23.02 07 54 23.02
C1 SECTION @ LIGHT MONITOR
1:25- A323
A1 SECTION @ ACTIVITIES ROOM
1:25A101B A323
A4 SECTION @ LIGHT MONITOR
1:25A101C A323
07 54 23.02
07 54 23.02
05 12 00.01
SEE
REFLECTED CEILING PLAN
3 500
BOT OF BEAM WRAP
2 700
SOFFIT
3 500
BOT OF BEAM WRAP
07 26 00.01
03 30 00.13
07 26 00.01
07 54 23.27
07 24 00.45
06 16 43.01
05 12 00.01
03 30 00.13
07 26 00.01
09 22 16.01
07 54 23.27
07 54 23.01
07 54 23.27
3 000
FIXTURE
26 00 00.02
B4
A523
05 41 00.01
05 41 00.01
05 41 00.01
05 41 00.01
3 000
FIXTURE
26 00 00.02
26 00 00.02
05 41 00.01
C5
A541
C5
A541
07 54 23.27
7 140
TO STEEL
5 185
TO STEEL
2 700
SOFFIT
23 00 00.08
23 00 00.02
09 51 23.01
23 00 00.02
05 41 00.01
05 41 00.01
05 41 00.01
07 54 23.02
09 29 00.20
09 29 00.20
09 29 00.20
03 30 00.05 - CONTINUOUS BUILDING APRON: 100 THICK, 450 WIDE
1:50 SLOPE
03 30 00.13 - CONCRETE SLAB ON GRADE
05 12 00.01 - STEEL BEAM
05 31 00.01 - STEEL ROOF DECK
05 41 00.01 - STEEL STUD; 152
06 16 43.01 - GLASS-MAT GYPSUM SHEATHING BOARD
07 21 00.09 - GLASS FIBER BLANKET INSULATION- R13
07 24 00.01 - 50 EXTERIOR INSULATION AND FINISH SYSTEM
07 24 00.45 - FLUID APPLIED VAPOR PERMEABLE AIR/WATER
RESISTIVE BARRIER
07 26 00.01 - UNDER-SLAB VAPOR RETARDER - SEE S502 FOR
INSTALLATION DETAILS
07 54 23.01 - THERMOPLASTIC POLYOLEFIN MEMBRANE ROOF
SYSTEM
07 54 23.02 - THERMOPLASTIC POLYOLEFIN MEMBRANE
07 54 23.22 - REGLET AND COUNTER FLASHING
07 54 23.26 - SCUPPER BEYOND
07 54 23.27 - 16 COVER BOARD
07 62 00.05 - METAL FLASHING
07 71 13.01 - MANUFACTURED ROOF COPING
08 41 13.01 - ALUMINUM FRAMED STOREFRONT SYSTEM
09 22 16.01 - GYPSUM BOARD CEILING ON GRID SUSPENSION
SYSTEM
09 29 00.05 - GYPSUM BOARD SOFFIT
09 29 00.06 - GYPSUM BOARD WRAP OVER BEAM. SMOOTH FINISH.
09 29 00.20 - GYPSUM BOARD: LEVEL 5 FINISH
09 51 23.01 - ACOUSTICAL TILE CEILING SYSTEM
23 00 00.02 - MECHANICAL DUCT
23 00 00.08 - DIFFUSER
26 00 00.02 - LIGHT FIXTURE, REFER TO ELECTRICAL
A323
WALL SECTIONS
AGOYO
PARRILL
REV
ISSUE: 10.15.15 - Submittal 3
PROJECT NO: 08-0110.001
CAD DWG FILE: 08-0110-A323.dwg