MATCH LINE

SHEET A103C

M A

T C

H

L I N

E

S H

E E

T A

A

D1

A211

D1

A210

C1

A215

07 54 23.01

07 41 13.01

07 54 23.25

07 54 23.01

07 54 23.01

07 54 23.01

23 00 00.01

07 41 13.09

07 62 00.07

07 54 23.01

07 54 23.01

A1

A322

A5

A325

A1

A323

A3

A322

A5

A325

SIM

A3

A326

A3

A326

A3

A329

A4

A323

A4

A323

A6

A322

A5

A329

A6

A322

SIM

A1

A329

SIM

A6

A329

C2

A324

D1

A212

22 00 00.01

07 54 23.31

A1

A215

07 41 13.01

07 41 13.01

07 41 13.09

07 62 00.07

A1

A214

A1

A214

A1

A214

07 41 13.01

07 71 13.09

07 71 13.07

07 71 13.07

07 54 23.01

07 71 13.07

07 71 13.07

07 41 13.01

07 41 13.29

07 54 23.35

07 54 23.35

07 54 23.35

B4

A214

B4

A214

07 54 23.25

07 54 23.25

07 41 13.01 - METAL ROOF PANEL SYSTEM

07 41 13.09 - INTEGRATED GUTTER

07 41 13.29 - PROVIDE WATERPROOF CLOSURE AT HIGH SIDE

OF RAKE TRIM

07 54 23.01 - THERMOPLASTIC POLYOLEFIN MEMBRANE ROOF

SYSTEM

07 54 23.25 - SCUPPER

07 54 23.31 - SEE D2/A523 FOR OVERFLOW SCUPPER

07 54 23.35 - THERMOPLASTIC POLYOLEFIN FLEXIBLE

WALKWAY

07 62 00.07 - GALVANIZED COLLECTOR BOX WITH OVERFLOW

AND 150 X 150 DOWNSPOUT

07 71 13.07 - COPING END TERM WITH INTEGRAL FLANGE. SEE

C4/A514. TYPICAL AT EACH PARAPET/WALL

INTERSECTION.

07 71 13.09 - SHOP-FABRICATED CORNER TRANSITION AT

INTERSECTION OF PARAPET AND CURTAIN WALL

SILL FLASHING (BELOW HIGH ROOF). SEE A322.

22 00 00.01 - ROOF DRAIN SYSTEM

23 00 00.01 - MECHANICAL EQUIPMENT

REV

ISSUE: 10.15.15 - Submittal 3

PROJECT NO: 08-0110.001

CAD DWG FILE: 08-0110-A103B.dwg

DRAWN BY:

CHECKED BY:

SHEET TITLE

DATE DESCRIPTION

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

E

21 3 4 5 6

D

C

B

A

D

C

B

A

21 3 4 5 6

A103B

ROOF PLAN

AREA B

PARRILL

PARRILL

ROOF PLAN

AREA B

1:100

SEE D4/A326 FOR SCREEN WALL

WATER DRAINS UNDER WALL -

ROOF SLOPE

THROUGH WALL SCUPPER

ROOF SLOPE ACHIEVED WITH TAPERED INSULATION

FLEXIBLE WALKWAYS

SHEET KEYNOTES

GENERAL SHEET NOTES

REFERENCE KEYNOTES

LEGEND

A. ALL UNITS ARE IN MILLIMETERS UNLESS OTHERWISE

NOTED.

C

B

A

D

E

SEE PLUMBING FOR ROOF DRAIN ASSEMBLY

1. SEE C2/A525 FOR DETAIL AT BEAM, TYPICAL

2. SEE A1/A214 FOR ELEVATION @ TYPICAL LIGHT

MONITOR

3. SEE D1/A521 FOR GATE.

4. SEE C1/A521 FOR LOUVER THROUGH WALL.

5. SEE D5/A524 FOR DETAIL AT BEAM, TYPICAL.

6. SEE E3/A525 SIMILAR

A M

VOLUME 2: Sheet 18 of 111