A103B - ROOF PLAN AREA B.pdf
PDF 473 KB Posted
- Solicitation number
- 75H701-20-Q-00014
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATCH LINE
SHEET A103C
M A
T C
H
L I N
E
S H
E E
T A
A
D1
A211
D1
A210
C1
A215
07 54 23.01
07 41 13.01
07 54 23.25
07 54 23.01
07 54 23.01
07 54 23.01
23 00 00.01
07 41 13.09
07 62 00.07
07 54 23.01
07 54 23.01
A1
A322
A5
A325
A1
A323
A3
A322
A5
A325
SIM
A3
A326
A3
A326
A3
A329
A4
A323
A4
A323
A6
A322
A5
A329
A6
A322
SIM
A1
A329
SIM
A6
A329
C2
A324
D1
A212
22 00 00.01
07 54 23.31
A1
A215
07 41 13.01
07 41 13.01
07 41 13.09
07 62 00.07
A1
A214
A1
A214
A1
A214
07 41 13.01
07 71 13.09
07 71 13.07
07 71 13.07
07 54 23.01
07 71 13.07
07 71 13.07
07 41 13.01
07 41 13.29
07 54 23.35
07 54 23.35
07 54 23.35
B4
A214
B4
A214
07 54 23.25
07 54 23.25
07 41 13.01 - METAL ROOF PANEL SYSTEM
07 41 13.09 - INTEGRATED GUTTER
07 41 13.29 - PROVIDE WATERPROOF CLOSURE AT HIGH SIDE
OF RAKE TRIM
07 54 23.01 - THERMOPLASTIC POLYOLEFIN MEMBRANE ROOF
SYSTEM
07 54 23.25 - SCUPPER
07 54 23.31 - SEE D2/A523 FOR OVERFLOW SCUPPER
07 54 23.35 - THERMOPLASTIC POLYOLEFIN FLEXIBLE
WALKWAY
07 62 00.07 - GALVANIZED COLLECTOR BOX WITH OVERFLOW
AND 150 X 150 DOWNSPOUT
07 71 13.07 - COPING END TERM WITH INTEGRAL FLANGE. SEE
C4/A514. TYPICAL AT EACH PARAPET/WALL
INTERSECTION.
07 71 13.09 - SHOP-FABRICATED CORNER TRANSITION AT
INTERSECTION OF PARAPET AND CURTAIN WALL
SILL FLASHING (BELOW HIGH ROOF). SEE A322.
22 00 00.01 - ROOF DRAIN SYSTEM
23 00 00.01 - MECHANICAL EQUIPMENT
REV
ISSUE: 10.15.15 - Submittal 3
PROJECT NO: 08-0110.001
CAD DWG FILE: 08-0110-A103B.dwg
DRAWN BY:
CHECKED BY:
SHEET TITLE
DATE DESCRIPTION
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
E
21 3 4 5 6
D
C
B
A
D
C
B
A
21 3 4 5 6
A103B
ROOF PLAN
AREA B
PARRILL
PARRILL
ROOF PLAN
AREA B
1:100
SEE D4/A326 FOR SCREEN WALL
WATER DRAINS UNDER WALL -
ROOF SLOPE
THROUGH WALL SCUPPER
ROOF SLOPE ACHIEVED WITH TAPERED INSULATION
FLEXIBLE WALKWAYS
SHEET KEYNOTES
GENERAL SHEET NOTES
REFERENCE KEYNOTES
LEGEND
A. ALL UNITS ARE IN MILLIMETERS UNLESS OTHERWISE
NOTED.
C
B
A
D
E
SEE PLUMBING FOR ROOF DRAIN ASSEMBLY
1. SEE C2/A525 FOR DETAIL AT BEAM, TYPICAL
2. SEE A1/A214 FOR ELEVATION @ TYPICAL LIGHT
MONITOR
3. SEE D1/A521 FOR GATE.
4. SEE C1/A521 FOR LOUVER THROUGH WALL.
5. SEE D5/A524 FOR DETAIL AT BEAM, TYPICAL.
6. SEE E3/A525 SIMILAR
A M
VOLUME 2: Sheet 18 of 111
File details come from the government source that posted it. Updated .