A101B - FIRST FLOOR PLAN AREA B HZ.pdf

PDF 834 KB Posted

Attached to
75H701-20-Q-00014, Pharmacy Windows at Fort Yuma Health Care Center
Solicitation number
75H701-20-Q-00014
Issued by

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

03 30 00.05 - CONTINUOUS BUILDING APRON: 100 THICK, 450

WIDE 1:50 SLOPE

04 25 05.01 - RAMMED EARTH WALL WITH FIELD APPLIED

SEALANT

04 25 05.02 - RAMMED EARTH COLUMN WITH FIELD APPLIED

SEALANT

05 12 00.02 - STEEL COLUMN

05 12 00.09 - BRACED FRAMING

05 50 00.19 - METAL PLATE DISPLAY CASE

08 81 13.01 - DECORATIVE GLAZING, TEMPERED

10 28 13.01 - PASS THROUGH SPECIMEN CABINET

10 44 13.01 - FIRE EXTINGUISHER CABINET, SEMI RECESSED

WITH EXTINGUISHER (SEE 10 44 16 FOR

EXTINGUISHER)

10 51 13.02 - BENCH

12 48 00.01 - FLOOR MAT, SEE DETAIL B2/I613

MATCH LINE

SHEET A101C

M A

T C

H

L I N

E

S H

E E

T A

A

E3/A901

C

A

B

A

B

A

A2/A903

A3/A903

B3/A903

B

A

D2/A903

B

A

D1

A211

D1

A210

C1

A215

03 30 00.05

04 25 05.01

04 25 05.01

12 48 00.01

04 25 05.02

05 12 00.02

A

A

03 30 00.05

E2/A901

A4/A903

1 1

4B

4A3

2A111

CW3

CW1

5A

D1

A401

E5

A402

D1

A401

E4

A402

2B

10 44 13.01

05 12 00.02

10 44 13.01

10 44 13.01

3B

E3/A901

10 28 13.01

A003

A013

A011

A009

A008

A007

A006A005

A014

A016

A015

A017

A002

A004

A023

A024

A025

A026

A027

A022

B01

B02 B03

B04

B05 B06

B07

B08

B13

B16

B17

B19B21

B22

B15

B26

B27

B23

B25

B28

B32

B31

B29

B33

B41

B46

B36

B53

B54

B56

B59

B58

B57

B62

B61

B49

B51 B35

B10

C06

B18

C16

A001

A012

A018

A019 A021

B31A

B31

B05

B10

C08

B06

A019

A021

A006

A003

A005

A009

A008

A007

A016

A015 A014

B55

B35

B45

B38

B62

B59

A017

B19

B29

B28

B16

B27

B26

B23A

B23

B25

B29A

B61

B15

B18

B33

B39

B54

B57

B17

B34

B48

B56

A013

A001A

A001

B33A

B32A

B22

B02A

B36

B37A

B42

A003A

A003B

B52

E

A

C2/A903

C1/A903

12 48 00.01

SIM

D1

A921

A3

A510

10 51 13.02

B48A

B49

B51

A013A

A1

A322

A5

A325

A1

A323

A3

A322

A5

A325

SIM

A3

A326

A3

A326

A3

A329

A4

A323

A4

A323

A6

A322

A5

A329

A6

A322

SIM

A1

A329

SIM

A6

A329

C2

A324

D1

A212

B3/A403

08 81 13.01

B1/A404

A1/A404

05 12 00.09

05 12 00.09

05 12 00.09

05 12 00.09

05 12 00.09

05 12 00.09

05 12 00.09

05 12 00.09

05 12 00.09

B55A

05 50 00.19

05 50 00.19

B09

B07

B04

B03

B02

REV

ISSUE: 10.15.15 - Submittal 3

PROJECT NO: 08-0110.001

CAD DWG FILE: 08-0110-A101B.dwg

DRAWN BY:

CHECKED BY:

SHEET TITLE

DATE DESCRIPTION

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

E

21 3 4 5 6

D

C

B

A

D

C

B

A

21 3 4 5 6

A101B

FIRST FLOOR PLAN

AREA B

PARRILL

PIERSON

GENERAL SHEET NOTES

SHEET KEYNOTES

A. ALL UNITS ARE IN MILLIMETERS UNLESS OTHERWISE

NOTED.

B. BASED ON PROGRAM OF REQUIREMENTS DATED

07-08-09 AND ON SCHEMATIC DRAWINGS APPROVED

08-07-09

C. TYPICAL INTERIOR ELEVATIONS:

SEE A405 FOR SINGLE OCCUPANT TOILET ROOMS

AND TYPICAL MOUNTING HEIGHT DIAGRAMS

D5/A401 FOR HOUSEKEEPING CLOSETS

E4/E5/A901 FOR PRIMARY CARE EXAM ROOMS

D. ALL DOOR FRAMES ARE LOCATED 100 FROM ADJACENT

WALL UNLESS OTHERWISE DIMENSIONED

WALL TYPES

SMOKE BARRIER REQUIRED BY NFPA

101 8.7.4.2

STRUCTURAL BRACE

ONE HOUR FIRE BARRIER

HIGHLOW

PLAN LEGEND

X#

OPENING ELEVATION

C

B

A

D

E

REFERENCE KEYNOTES

KEYPLAN

FLOOR PLAN

AREA B

1:100

1. BEAM ABOVE - SEE STRUCTURAL

2. PIPING UP THROUGH CHASE

3. PLUMBING FIXTURE LOCATED IN SYSTEMS FURNITURE

4. UTILITY TRENCH BELOW - SEE B4/S501

5. BARIATRIC TOILET LOCATED 600 MIN. FROM SIDE WALL.

A M

VOLUME 2: Sheet 12 of 111

File details come from the government source that posted it. Updated .