751_19152.JBB_PlansPart-5.pdf

PDF 1 MB Posted

Attached to
751/19152. JBB; Fort Wilkins SP - Water System Upgrades
Solicitation number
RFQ - 171 - 220000000246
Issued by
Keweenaw County, Michigan

About this file

The document provided contains electrical plans and details for the Fort Wilkins State Park - Water System Upgrades project, which is being managed by the Michigan Department of Technology, Management and Budget, Facilities and Business Services Administration, Design and Construction Division. The project involves upgrades to the electrical systems for the West Campground and the Park Headquarters, including the installation of new grinder pumps, well pumps, and associated conduits and wiring. The plans provide detailed schematics and wiring diagrams for the electrical components. The related state and local contract opportunity provides additional details on the project, including the requirement for all bid attachments to be uploaded to the SIGMA VSS system, and COVID-19 precautions that may be in place, such as mask-wearing requirements.

The contract opportunity document also specifies that all questions should be emailed to the project manager, Jeff Barsch, and that emailed proposal submissions may be accepted on a case-by-case basis if SIGMA VSS issues arise. The contract is for the state of Michigan, with the project location in Keweenaw County. No specific pricing terms, set-asides, incumbent information, or funding details are provided in the documents reviewed.

View the file

Other files

File Type Posted
751_19152.JBB_PlansPart-3.pdf PDF
Addendum 3 19152.pdf PDF
751_19152.JBB_Advertisement.pdf PDF
Addendum 2 19152.pdf PDF
Addendum 1 19152.pdf PDF
751_19152.JBB_Technical Specifications.pdf PDF
751_19152.JBB_PlansPart-1.pdf PDF
751_19152.JBB_PlansPart-2.pdf PDF
751_19152.JBB_PlansPart-4.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

20A

PANEL W-1

240V/120V, 1ɸ, 3W, SERVICE

RATED, 800A MCB

MAIN

BREAKER

800A

30A

SPACE

SPACE

GRINDER

PUMP

MINI

CABIN

SHOWER

BUILDING

60A

GRINDER PUMP

(MINI CABIN)

100A

PEDESTALS

- G

PEDESTALS

- J

PEDESTALS

- F

100A

PEDESTALS

- I

PEDESTALS

- H

PEDESTALS

- E

100A

100A

100A

100A

30A

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E

R

E

I S

P E

N I

N S

U

L A

M

A

M

O

E

N

A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ Fo rt_ W ilk ins

_S ew er _S ys _U pg ra de s\D ra wi ng s\C ivi l\P lan s_

Co ns t\1

0C

ON

_E

LE

CT

RI

CA

L P

LA

NS

.dw g M ar

, 2

2 -

:26 am

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

Know what's below.

before you dig.Call

R

WEST CAMPGROUND ELECTRICAL PLAN1

EXISTING PANEL W-1

RACK FOR PUMP CONTROL PANEL.

SEE DETAIL 2 THIS SHEET.

EXISTING UTILITY TRANSFORMER

1 1/4" PVC SCHEDULE 40 CONDUIT

W/ 3-#8AWG + #8G

RACK DETAIL2

PROPOSED GRINDER PUMP LOCATION.

PROVIDE 1 1/4" GALVANIZED RIGID CONDUIT

LEAVING PUMP CHAMBER FOR PUMP SO

CORD PER PUMP MANUFACTURER

INSTRUCTIONS. SEE SPEC SECTION 221329

FOR GRINDER PUMP AND CONTROLS.

feetGRAPHIC SCALE: FULL feetHALF

4530158

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E

R

E

I S

P E

N I

N S

U

L A

M

A

M

O

E

N

A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ Fo rt_ W ilk ins

_S ew er _S ys _U pg ra de s\D ra wi ng s\C ivi l\P lan s_

Co ns t\1

0C

ON

EL

EC

TR

IC

AL

P

UM

P

PL

AN

S.

dw g M ar

, 2

2 -

:27 am

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

Know what's below.

before you dig.Call

R feetGRAPHIC SCALE: FULL feetHALF

3020105

POLE BARN

SHOP

PARK HEADQUARTER'S ELECTRICAL PLAN1

PUMP P1

PUMP P2

FWHSP

3" PVC CONDUIT WITH SOW

CORD CONTAINING 3-#8AWG

CONDUCTORS.

PP1

3" PVC CONDUIT WITH SOW CORD

CONTAINING 3-#8AWG CONDUCTORS AND

1 1/2" CONDUIT WITH MANUFACTURER

SUPPLIED CABLE FOR LEVEL

TRANSMITTER.

PUMP P2 MOTOR STARTER

SEE SHEET E-301 FOR PUMP

SEQUENCE.

PUMP P1 MOTOR STARTER

SEE SHEET E-301 FOR PUMP

SEQUENCE.

PUMP CONTROL ENCLOSURE TERMINATE

LEVEL TRANSMITTER HERE. SEE WATER

PUMP SPECIFICATIONS FOR DETAILS

1 1/2" CONDUIT WITH 2-#8AWG + #8GND

1 1/2" CONDUIT WITH 2-#8AWG + #8GND

FWHSP DESCRIPTION: EXISTING PANEL SURFACE MOUNT, 240/120V, 1ɸ, 3W, 225A, MLO, 42 CIRCUIT, 22k SCCR, LOCATED IN ELEC RM 101

IDENTIFICATION

KVA LOAD

WIRE POLE AMP

C I R

C U

I T

C I R

C U

I T

AMP POLE WIRE

KVA LOAD

IDENTIFICATIONA B B A

MAIN 0.00 EX. 1 100 20 1 EX. 0.00 UNAVAILABLE

WOODSHOP OUTLETS 1,3,4,8,9, EXHAUST FAN E.

& W. OUTSIDE CENTER WALL OUTLETS

0.00 EX. 1 20 14 13 20 1 EX. 0.00

STALL 1&2 OUTLETS, EXHAUST FAN, LIGHT

ABOVE E. ENTRANCE DOOR STALL 2 LIGHTS,

ATTIC LIGHTS, S.W. OUTSIDE WALL OUTLET

STALL 3 S. WALL OUTLET 120V, STALL 1 E.

EXTERIOR LIGHT, STREET LIGHT BY FUEL TANKS

WATER HEATER

EX. 2 30

1 7 20 1 EX. -

WOODSHOP OUTLETS 2,5,6,7, S. WALL OUTLET 5,

OUTLET 10

- 2 8 20 1 EX. -

E.OFFICE OUTLETS, W. OFFICE E. WALL

OUTLETS, FURNACE

S. 1ST STALL WELDER 220 OUTLET, N 6TH STALL

ELEC PANEL, WOODSHOP, STALLS 5&6 LIGHTS

N.E., N.W. OUTSIDE OUTLETS WOODSHOP

OUTLETS

EX. 2 60

3 9 20 1 EX. -

W. OFFICE LIGHTS, OUTLETS BATHROOM

- 4 10 20 1 EX. -

E. OFFICE LIGHTS 1ST STALL LIGHTS, TROUBLE

LIGHT OUTLET, ATTIC OUTLET

WOODSHOP TABLE SAW 220V OUTLET

EX. 2 20

5 11 20 1 EX. - UNKNOWN

- 6 12 20 1 EX. - WOODSHOP S. WALL 220V OUTLETS

CONNECTED LOAD 0.00 0.00 0.00 0.00 CONNECTED LOAD

PANEL PP1 DESCRIPTION: EXISTING PANEL SURFACE MOUNT, 240/120V, 1ɸ, 3W, 225A, MLO, 42 CIRCUIT, 22k SCCR, LOCATED IN ELEC RM 101

IDENTIFICATION

KVA LOAD

WIRE POLE AMP

C I R

C U

I T

C I R

C U

I T

AMP POLE WIRE

KVA LOAD

IDENTIFICATIONA B B A

MAIN

0.00

EX. 2 100

1 2 0.00 SPACE

0.00 3 4 0.00 SPACE

GRINDER PUMP SHOP

EX. 2 20

5 6

50 2 EX.

WELDER

- 7 8 -

OUTLETS, OVER HEAD DOOR, OLD PAINT

- EX. 1 20 9 10 20 1 EX. - LIGHTS NORTH AND MIDDLE BAYS

LOFT LIGHT AND FAN - EX. 1 15 11 12

15 2 EX.

220 TEST OUTLET FOR GRINDER

OUTLET BELOW PANEL, OUTLETS NORTH END

INSIDE OUT

- EX. 1 20 13 14 -

GRINDER PUMP A -

EX. 2 30

15 16

25 2 8

WELL PUMP P1

TEST PANEL A - 17 18 -

SPACE - 19 20

25 2 8

WELL PUMP P2

SPACE - 21 22 -

SPACE - 23 24 20 1 12 - CONTROL POWER

CONNECTED LOAD 0.00 0.00 0.00 0.00 CONNECTED LOAD

WELL PUMP P1 MOTOR STARTER CONTROL DIAGRAM1

WELL PUMP P2 MOTOR STARTER CONTROL DIAGRAM2

LEVEL TRANSMITTER MOUNTING DETAIL3

P

L

U

R

I B

U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E

R

E

I S

P E

N I

N S

U

L A

M

A

M

O

E

N

A

M

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

P:

\71

_7

0\7

0_ Fo rt_ W ilk ins

_S ew er _S ys _U pg ra de s\D ra wi ng s\C ivi l\P lan s_

Co ns t\1

0C

ON

_E

LE

CT

RI

CA

L D

ET

AI

LS

.dw g

M ar

, 2

2 -

:27 am

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

FA

CI

LI

TI

ES

A

N D

B U

SI

N

ES

S

SE

RV

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH. 906.482.0535

F 906.482.6453

Know what's below.

before you dig.Call

R

File details come from the government source that posted it. Updated .