The document provided contains electrical plans and details for the Fort Wilkins State Park - Water System Upgrades project, which is being managed by the Michigan Department of Technology, Management and Budget, Facilities and Business Services Administration, Design and Construction Division. The project involves upgrades to the electrical systems for the West Campground and the Park Headquarters, including the installation of new grinder pumps, well pumps, and associated conduits and wiring. The plans provide detailed schematics and wiring diagrams for the electrical components. The related state and local contract opportunity provides additional details on the project, including the requirement for all bid attachments to be uploaded to the SIGMA VSS system, and COVID-19 precautions that may be in place, such as mask-wearing requirements.
The contract opportunity document also specifies that all questions should be emailed to the project manager, Jeff Barsch, and that emailed proposal submissions may be accepted on a case-by-case basis if SIGMA VSS issues arise. The contract is for the state of Michigan, with the project location in Keweenaw County. No specific pricing terms, set-asides, incumbent information, or funding details are provided in the documents reviewed.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
20A
PANEL W-1
240V/120V, 1ɸ, 3W, SERVICE
RATED, 800A MCB
MAIN
BREAKER
800A
30A
SPACE
SPACE
GRINDER
PUMP
MINI
CABIN
SHOWER
BUILDING
60A
GRINDER PUMP
(MINI CABIN)
100A
PEDESTALS
- G
PEDESTALS
- J
PEDESTALS
- F
100A
PEDESTALS
- I
PEDESTALS
- H
PEDESTALS
- E
100A
100A
100A
100A
30A
P
L
U
R
I B
U
E
S
U
N
U
M
C
I
R
C
U M
S
P
I
C
E
S
I
Q
U
E
R
E
I S
P E
N I
N S
U
L A
M
A
M
O
E
N
A
M
ARCHITECTS. ENGINEERS. PLANNERS
OHM-ADVISORS.COM
P:
\71
_7
0\7
0_ Fo rt_ W ilk ins
_S ew er _S ys _U pg ra de s\D ra wi ng s\C ivi l\P lan s_
Co ns t\1
0C
ON
_E
LE
CT
RI
CA
L P
LA
NS
.dw g M ar
, 2
2 -
:26 am
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
FA
CI
LI
TI
ES
A
N D
B U
SI
N
ES
S
SE
RV
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH. 906.482.0535
F 906.482.6453
Know what's below.
before you dig.Call
R
WEST CAMPGROUND ELECTRICAL PLAN1
EXISTING PANEL W-1
RACK FOR PUMP CONTROL PANEL.
SEE DETAIL 2 THIS SHEET.
EXISTING UTILITY TRANSFORMER
1 1/4" PVC SCHEDULE 40 CONDUIT
W/ 3-#8AWG + #8G
RACK DETAIL2
PROPOSED GRINDER PUMP LOCATION.
PROVIDE 1 1/4" GALVANIZED RIGID CONDUIT
LEAVING PUMP CHAMBER FOR PUMP SO
CORD PER PUMP MANUFACTURER
INSTRUCTIONS. SEE SPEC SECTION 221329
FOR GRINDER PUMP AND CONTROLS.
feetGRAPHIC SCALE: FULL feetHALF
4530158
P
L
U
R
I B
U
E
S
U
N
U
M
C
I
R
C
U M
S
P
I
C
E
S
I
Q
U
E
R
E
I S
P E
N I
N S
U
L A
M
A
M
O
E
N
A
M
ARCHITECTS. ENGINEERS. PLANNERS
OHM-ADVISORS.COM
P:
\71
_7
0\7
0_ Fo rt_ W ilk ins
_S ew er _S ys _U pg ra de s\D ra wi ng s\C ivi l\P lan s_
Co ns t\1
0C
ON
EL
EC
TR
IC
AL
P
UM
P
PL
AN
S.
dw g M ar
, 2
2 -
:27 am
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
FA
CI
LI
TI
ES
A
N D
B U
SI
N
ES
S
SE
RV
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH. 906.482.0535
F 906.482.6453
Know what's below.
before you dig.Call
R feetGRAPHIC SCALE: FULL feetHALF
3020105
POLE BARN
SHOP
PARK HEADQUARTER'S ELECTRICAL PLAN1
PUMP P1
PUMP P2
FWHSP
3" PVC CONDUIT WITH SOW
CORD CONTAINING 3-#8AWG
CONDUCTORS.
PP1
3" PVC CONDUIT WITH SOW CORD
CONTAINING 3-#8AWG CONDUCTORS AND
1 1/2" CONDUIT WITH MANUFACTURER
SUPPLIED CABLE FOR LEVEL
TRANSMITTER.
PUMP P2 MOTOR STARTER
SEE SHEET E-301 FOR PUMP
SEQUENCE.
PUMP P1 MOTOR STARTER
SEE SHEET E-301 FOR PUMP
SEQUENCE.
PUMP CONTROL ENCLOSURE TERMINATE
LEVEL TRANSMITTER HERE. SEE WATER
PUMP SPECIFICATIONS FOR DETAILS
1 1/2" CONDUIT WITH 2-#8AWG + #8GND
1 1/2" CONDUIT WITH 2-#8AWG + #8GND
FWHSP DESCRIPTION: EXISTING PANEL SURFACE MOUNT, 240/120V, 1ɸ, 3W, 225A, MLO, 42 CIRCUIT, 22k SCCR, LOCATED IN ELEC RM 101
IDENTIFICATION
KVA LOAD
WIRE POLE AMP
C I R
C U
I T
C I R
C U
I T
AMP POLE WIRE
KVA LOAD
IDENTIFICATIONA B B A
MAIN 0.00 EX. 1 100 20 1 EX. 0.00 UNAVAILABLE
WOODSHOP OUTLETS 1,3,4,8,9, EXHAUST FAN E.
& W. OUTSIDE CENTER WALL OUTLETS
0.00 EX. 1 20 14 13 20 1 EX. 0.00
STALL 1&2 OUTLETS, EXHAUST FAN, LIGHT
ABOVE E. ENTRANCE DOOR STALL 2 LIGHTS,
ATTIC LIGHTS, S.W. OUTSIDE WALL OUTLET
STALL 3 S. WALL OUTLET 120V, STALL 1 E.
EXTERIOR LIGHT, STREET LIGHT BY FUEL TANKS
WATER HEATER
EX. 2 30
1 7 20 1 EX. -
WOODSHOP OUTLETS 2,5,6,7, S. WALL OUTLET 5,
OUTLET 10
- 2 8 20 1 EX. -
E.OFFICE OUTLETS, W. OFFICE E. WALL
OUTLETS, FURNACE
S. 1ST STALL WELDER 220 OUTLET, N 6TH STALL
ELEC PANEL, WOODSHOP, STALLS 5&6 LIGHTS
N.E., N.W. OUTSIDE OUTLETS WOODSHOP
OUTLETS
EX. 2 60
3 9 20 1 EX. -
W. OFFICE LIGHTS, OUTLETS BATHROOM
- 4 10 20 1 EX. -
E. OFFICE LIGHTS 1ST STALL LIGHTS, TROUBLE
LIGHT OUTLET, ATTIC OUTLET
WOODSHOP TABLE SAW 220V OUTLET
EX. 2 20
5 11 20 1 EX. - UNKNOWN
- 6 12 20 1 EX. - WOODSHOP S. WALL 220V OUTLETS
CONNECTED LOAD 0.00 0.00 0.00 0.00 CONNECTED LOAD
PANEL PP1 DESCRIPTION: EXISTING PANEL SURFACE MOUNT, 240/120V, 1ɸ, 3W, 225A, MLO, 42 CIRCUIT, 22k SCCR, LOCATED IN ELEC RM 101
IDENTIFICATION
KVA LOAD
WIRE POLE AMP
C I R
C U
I T
C I R
C U
I T
AMP POLE WIRE
KVA LOAD
IDENTIFICATIONA B B A
MAIN
0.00
EX. 2 100
1 2 0.00 SPACE
0.00 3 4 0.00 SPACE
GRINDER PUMP SHOP
EX. 2 20
5 6
50 2 EX.
WELDER
- 7 8 -
OUTLETS, OVER HEAD DOOR, OLD PAINT
- EX. 1 20 9 10 20 1 EX. - LIGHTS NORTH AND MIDDLE BAYS
LOFT LIGHT AND FAN - EX. 1 15 11 12
15 2 EX.
220 TEST OUTLET FOR GRINDER
OUTLET BELOW PANEL, OUTLETS NORTH END
INSIDE OUT
- EX. 1 20 13 14 -
GRINDER PUMP A -
EX. 2 30
15 16
25 2 8
WELL PUMP P1
TEST PANEL A - 17 18 -
SPACE - 19 20
25 2 8
WELL PUMP P2
SPACE - 21 22 -
SPACE - 23 24 20 1 12 - CONTROL POWER
CONNECTED LOAD 0.00 0.00 0.00 0.00 CONNECTED LOAD
WELL PUMP P1 MOTOR STARTER CONTROL DIAGRAM1
WELL PUMP P2 MOTOR STARTER CONTROL DIAGRAM2
LEVEL TRANSMITTER MOUNTING DETAIL3
P
L
U
R
I B
U
E
S
U
N
U
M
C
I
R
C
U M
S
P
I
C
E
S
I
Q
U
E
R
E
I S
P E
N I
N S
U
L A
M
A
M
O
E
N
A
M
ARCHITECTS. ENGINEERS. PLANNERS
OHM-ADVISORS.COM
P:
\71
_7
0\7
0_ Fo rt_ W ilk ins
_S ew er _S ys _U pg ra de s\D ra wi ng s\C ivi l\P lan s_
Co ns t\1
0C
ON
_E
LE
CT
RI
CA
L D
ET
AI
LS
.dw g
M ar
, 2
2 -
:27 am
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
FA
CI
LI
TI
ES
A
N D
B U
SI
N
ES
S
SE
RV
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH. 906.482.0535
F 906.482.6453
Know what's below.
before you dig.Call
R
File details come from the government source that posted it. Updated .