This is a construction site plan drawing showing the conceptual layout for a mobile batch plant and associated utilities at what appears to be an airfield facility. The drawing includes notes detailing specific requirements for the contractor's mobile batch plant operations, including:
The plan shows the proposed location of the mobile batch plant with water and electrical connections marked in red, along with a contractor laydown area near what is labeled as "NORTH GATE." The drawing includes a scale (1" = 100') and appears to be sheet C-003 of a larger set of construction documents. Key contractor requirements specified in the notes include: coordination of utility connections and installation of their own utility meter, ensuring plant operations don't block site traffic, potential installation of security fencing (optional), and specific utility rate information ($0.07 per kWh for electrical). The plan indicates coordination requirements with Elizabeth City for water connections, calculated at 2024 USGS rates for billing purposes.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GV
T
AutoCAD SHX Text 8.06
AutoCAD SHX Text 7.9
AutoCAD SHX Text 6.80
AutoCAD SHX Text 6.60
AutoCAD SHX Text 7.01
AutoCAD SHX Text 6.94
AutoCAD SHX Text 7.14
AutoCAD SHX Text 7.4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
42" ST
AutoCAD SHX Text
10" ST
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
4" FUEL TRANSFER PIPE
AutoCAD SHX Text 6"W
AutoCAD SHX Text 8"W
AutoCAD SHX Text
EMH #24
AutoCAD SHX Text
XFMR ON CONC SLAB
AutoCAD SHX Text
ELEC. SUB-STATION
AutoCAD SHX Text
W/CONC SLAB, 6'C.L.
AutoCAD SHX Text
FENCE
AutoCAD SHX Text
SPALLED
AutoCAD SHX Text T/W `J'
AutoCAD SHX Text
EMH #23
AutoCAD SHX Text
TEL. PED.
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text
TBM#1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text 6"W
AutoCAD SHX Text E
AutoCAD SHX Text
4" FUEL TRANSFER PIPE
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text 0+00
AutoCAD SHX Text B R/W 1-19
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
6 PW
AutoCAD SHX Text
6 PW
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
42 ST
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
36 ST
AutoCAD SHX Text
36 ST
AutoCAD SHX Text
36 ST
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
FA
AutoCAD SHX Text E
AutoCAD SHX Text
FA
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
PEDESTAL
AutoCAD SHX Text
6 PW
AutoCAD SHX Text
6 PW
AutoCAD SHX Text
6 PW
AutoCAD SHX Text
6 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
1.5 SAN
AutoCAD SHX Text
1.5 SAN
AutoCAD SHX Text
FA
AutoCAD SHX Text
FA
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
9 SAN
AutoCAD SHX Text
9 SAN
AutoCAD SHX Text
4 SAN
AutoCAD SHX Text
4 SAN
AutoCAD SHX Text
4 SAN
AutoCAD SHX Text
4 SAN
AutoCAD SHX Text
4 SAN
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
8 SAN
AutoCAD SHX Text
12 ST
AutoCAD SHX Text
12 ST
AutoCAD SHX Text
12 ST
AutoCAD SHX Text
12 ST
AutoCAD SHX Text
10 ST
AutoCAD SHX Text
10 ST
AutoCAD SHX Text
8 PW
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
1.5 PW
AutoCAD SHX Text
1.5 PW
AutoCAD SHX Text
1.5 PW
AutoCAD SHX Text
1.5 PW
AutoCAD SHX Text
1.5 PW
AutoCAD SHX Text
1.5 PW
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
6 SAN
AutoCAD SHX Text
4 SAN
AutoCAD SHX Text
16 ST
AutoCAD SHX Text
16 ST
AutoCAD SHX Text E
AutoCAD SHX Text
6 SAN
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
6 SAN
AutoCAD SHX Text
6 SAN
AutoCAD SHX Text
6 SAN
AutoCAD SHX Text
16 ST
AutoCAD SHX Text
16 ST
AutoCAD SHX Text E
AutoCAD SHX Text
12 ST
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
6 SAN
AutoCAD SHX Text
6 SAN
AutoCAD SHX Text E
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
12 SAN
AutoCAD SHX Text
48 ST
AutoCAD SHX Text
48 ST
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
36 ST
AutoCAD SHX Text
36 ST
AutoCAD SHX Text
1.5 SAN
AutoCAD SHX Text
1.5 SAN
AutoCAD SHX Text
1.5 SAN
AutoCAD SHX Text
1.5 SAN
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
FA
AutoCAD SHX Text
FA
AutoCAD SHX Text
FA
AutoCAD SHX Text
FA
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
10 ST
AutoCAD SHX Text
8 PW
AutoCAD SHX Text
10 ST
AutoCAD SHX Text
12 ST
AutoCAD SHX Text
12 ST
AutoCAD SHX Text
42 ST
AutoCAD SHX Text
42 ST
AutoCAD SHX Text
10 ST
AutoCAD SHX Text
10 ST
AutoCAD SHX Text
10 ST
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
10 SAN
AutoCAD SHX Text
48 ST
AutoCAD SHX Text
48 ST
AutoCAD SHX Text
48 ST
AutoCAD SHX Text
48 ST
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
AutoCAD SHX Text
MARK
AutoCAD SHX Text
EDITED BY:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text G
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
PLOTTING SCALE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
USCG DRAWING N0.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
USCG PROJECT NO.
AutoCAD SHX Text
USCG FILENAME
AutoCAD SHX Text
A/E COMPANY:
AutoCAD SHX Text
CONSULTING A/E:
AutoCAD SHX Text
PROJECT ENGINEER:
AutoCAD SHX Text
A/E PROJECT NO.:
AutoCAD SHX Text
SHEET ID
AutoCAD SHX Text
RECAPITALIZE R/W 1-19
AutoCAD SHX Text
AIR STATION ELIZABETH CITY
AutoCAD SHX Text
ELIZABETH CITY
AutoCAD SHX Text
NC
AutoCAD SHX Text
CIVIL
AutoCAD SHX Text
CONCEPTUAL BATCH PLANT SITE
AutoCAD SHX Text
AIRSTA E-CITY
AutoCAD SHX Text C-003
AutoCAD SHX Text 10393282
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FDCC
AutoCAD SHX Text
5505 ROBIN HOOD RD, SUITE K
AutoCAD SHX Text
NORFOLK, VA 23513
AutoCAD SHX Text 1:1
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
AutoCAD SHX Text
RFP CONCEPT
AutoCAD SHX Text 13/12/22
AutoCAD SHX Text
U.S. COAST GUARD
AutoCAD SHX Text
CIVIL ENGINEERING
AutoCAD SHX Text CONCEPTUAL MOBILE BATCH PLANT NOTES: 1. THE PROPOSED LOCATION OF THE MOBILE BATCH PLANT SHALL BE AS INDICATED BELOW THE PROPOSED LOCATION OF THE MOBILE BATCH PLANT SHALL BE AS INDICATED BELOW 2. THE CONTRACTOR'S MOBILE BATCH PLANT AND PLANT OPERATIONS SHALL NOT BLOCK OR THE CONTRACTOR'S MOBILE BATCH PLANT AND PLANT OPERATIONS SHALL NOT BLOCK OR RESTRICT VEHICLE TRAFFIC MOVEMENTS FOR OVERALL SITE. 3. THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION AND UTILITY CONNECTIONS, FEES, THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION AND UTILITY CONNECTIONS, FEES, AND PERMITS. THE CONTRACTOR SHALL PROVIDE AND INSTALL THEIR OWN UTILITY METER. THE CONTRACTOR SHALL FIELD VERIFY ALL UTILITY REQUIREMENTS. THE GOVERNMENT SHALL NOT BE MADE RESPONSIBLE FOR FIELD VERIFYING UTILITY CAPABILITIES TO MEET THE CONTRACTOR'S MOBILE BATCH PLANT REQUIREMENTS. 3.1. POTABLE WATER: CONNECTION SHALL BE COORDINATED WITH THE ELIZABETH CITY. POTABLE WATER: CONNECTION SHALL BE COORDINATED WITH THE ELIZABETH CITY. CONNECTION SHOULD BE UPSTREAM OF THE USCG BASE ELIZABETH CITY METER. THE CONTRACTOR IS RESPONSIBLE FOR WATER USAGE WITH ELIZABETH CITY AND NOT THROUGH THE USCG. FOR BIDDING PURPOSES, THE WATER RATE IS CALCULATED FROM THE 2024 AVERAGE RATE OF $28.06 PER 1,000-GALLONS. 3.2. ELECTRICAL: CONNECTION SHALL BE RESPONSIBLE FOR ELECTRICAL REIMBURSEMENT TO THE ELECTRICAL: CONNECTION SHALL BE RESPONSIBLE FOR ELECTRICAL REIMBURSEMENT TO THE USCG. FOR BIDDING PURPOSES, ASSUME A RATE OF $0.07 PER KWH. 4. THE CONTRACTOR IS AUTHORIZED, BUT NOT REQUIRED TO PROVIDE AND INSTALL A SECURITY THE CONTRACTOR IS AUTHORIZED, BUT NOT REQUIRED TO PROVIDE AND INSTALL A SECURITY FENCE FOR THEIR PROTECTION OF THE MOBILE BATCH PLANT.
AutoCAD SHX Text
NORTH GATE
AutoCAD SHX Text
CONCEPTUAL MOBILE BATCH PLANT
AutoCAD SHX Text
CONTRACTOR LAYDOWN
AutoCAD SHX Text
CONCEPTUAL ELECTRICAL CONNECTION
AutoCAD SHX Text
CONCEPTUAL WATER CONNECTION (BURIED)
AutoCAD SHX Text 300'
AutoCAD SHX Text 1" = 100'
AutoCAD SHX Text
AutoCAD SHX Text 200'
AutoCAD SHX Text 100'
AutoCAD SHX Text 500'
AutoCAD SHX Text 400'
| Sheets and Views |
| C-003 |
File details come from the government source that posted it. Updated .