7_ LDD Blueline Ambucs Park Gym PG SG_101_Ram.pdf
PDF 806 KB Posted
- Attached to
- 2025-002 INODIC GRANTS PARK IMPROVEMENT PROJECTS
- Solicitation number
- PE-72600-NONST-2025-000000017
- Issued by
- Talbot County, Georgia
About this file
The document is a structural drawing set for the Ambucs Park Gym component of the 2025-002 INODIC Grants Park Improvement Projects, which is a state and local contract opportunity in Talbot County, Georgia. The project involves upgrading an existing youth sports facility at Ambucs Park, including the gymnasium, baseball fields, walkways, lighting, and other site improvements. The structural details cover the design of the gym ramps, retaining walls, and concrete work. The overall park improvement project also includes upgrades to the Volunteer Park facilities with new fields, buildings, and site amenities.
The contract opportunity requires the installation of new sod, infield material, ADA access ramp, walkways, bleachers, batting cages, dugouts, lighting, and stormwater system upgrades at Ambucs Park. The project will also include new parking spaces, buildings, and site improvements at Volunteer Park. The contract is being procured by the state of Georgia and Talbot County, with an expected award date not provided in the documents.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SG-101
GYM -
STRUCTURAL
NOTES & DETAILS
w w w .ld db lu el in e.
co m
LD
D
B lu el in e D is co ve r
D es ig n
D el iv er
TM
A rc hi te ct ur e
In te rio r D es ig n S tra te gi c
P la nn in g
S us ta in ab le
D es ig n
REV DATE: ISSUED FOR:
ALL DESIGNS, GRAPHICS, AND DATA ON THIS SET OF
DRAWINGS ARE THE INTELLECTUAL PROPERTY OF
LDDBLUELINE, INC. AND HAVE BEEN CREATED AND
DEVELOPED FOR THIS SPECIFIC PROJECT. USE OF ALL
INTELLECTUAL PROPERTY BY ANY PERSON, FIRM OR
CORPORATION FOR ANY PURPOSE IS UNAUTHORIZED
WITHOUT THE WRITTEN PERMISSION OF LDDBLUELINE,
INC. IF DISCREPANCIES ARE FOUND BETWEEN ANY
ELECTRONIC FILES AND THE SEALED ORIGINAL, THE
SEALED ORIGINAL SHALL GOVERN.
COPYRIGHT: 2024
PROJECT NO.:
DRAWN BY: QC:
11/14/2024 ADDENDUM #2
1024010.02
DWH DWH
H K
S E
H a r r e l l K a n e S t r u c t u r a l E n g in e e r s
In c
O l d R o s w e l l R o a d
R o s w e l l
G e o r g ia p h
.9
.4
S u it e
REGIST
NO. SE000055
ENG NEEI
STRUCTURAL
D
ERED
R
G
A
AIROEG
AV ID W. H R
ER
LL
11/14/2024
SU
PP
O R
T
BU
IL
D
IN
G
S
FO
R
H ig h Fa lls R oa d, S pa ld in g C ou nt y, G
A
A M
B U
C S
P A
R K
B A
S E
B A
LL
C
O M
P
LE
X
AutoCAD SHX Text
SLABS AND WALLS
AutoCAD SHX Text
#5 BARS AND SMALLER
AutoCAD SHX Text
#6 THROUGH #18 BARS
AutoCAD SHX Text
FORMED CONCRETE EXPOSED TO EARTH OR WEATHER
AutoCAD SHX Text
CONCRETE NOT EXPOSED TO EARTH OR WEATHER
AutoCAD SHX Text
CONCRETE AGAINST EARTH (NOT FORMED)
AutoCAD SHX Text
REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE COVER UNLESS
AutoCAD SHX Text
NOTED OTHERWISE:
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 3"
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
SUPERIMPOSED DESIGN LIVE LOADS
AutoCAD SHX Text REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE STRUCTURAL ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW AND CHECK SHOP DRAWINGS BEFORE SUBMITTAL TO THE STRUCTURAL ENGINEER. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES OF CONSTRUCTION.
AutoCAD SHX Text COORDINATE STRUCTURAL CONTRACT DOCUMENTS WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL. NOTIFY STRUCTURAL ENGINEER OF ANY CONFLICT AND/OR OMISSION.
AutoCAD SHX Text THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC.
AutoCAD SHX Text NOTIFY THE STRUCTURAL ENGINEER IN WRITING OF CONDITIONS ENCOUNTERED IN THE FIELD CONTRADICTORY TO THOSE SHOWN ON THE STRUCTURAL CONTRACT DOCUMENTS.
AutoCAD SHX Text VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. NOTIFY STRUCTURAL ENGINEER OF ANY DISCREPANCY.
AutoCAD SHX Text DRAWINGS SHOW TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. FOR DETAILS NOT SPECIFICALLY SHOWN, PROVIDE DETAILS SIMILAR TO THOSE SHOWN.
AutoCAD SHX Text ALL CONSTRUCTION SHALL CONFORM TO THE 2018 INTERNATIONAL BUILDING CODE W/ GEORGIA AMENDMENTS. OTHER REFERENCES TO STANDARD SPECIFICATIONS OR CODES SHALL MEAN THE LATEST STANDARD OR CODE ADOPTED.
AutoCAD SHX Text
FOR DIMENSIONS NOT SHOWN SEE ARCHITECTURAL DRAWINGS.
AutoCAD SHX Text
RAMPS/STAIRS/PLATFORMS
AutoCAD SHX Text 1.09
AutoCAD SHX Text 1.01
AutoCAD SHX Text 1.08
AutoCAD SHX Text 1.07
AutoCAD SHX Text 1.06
AutoCAD SHX Text 1.03
AutoCAD SHX Text 1.05
AutoCAD SHX Text 1.04
AutoCAD SHX Text 1.02
AutoCAD SHX Text %%u1.00 GENERAL
AutoCAD SHX Text GEOTECHNICAL ENGINEER SHALL VERIFY CONDITION AND ADEQUACY OF ALL SUB GRADES, FILLS, AND BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, SLABS, AND WALLS.
AutoCAD SHX Text DO NOT BACKFILL AGAINST FOUNDATION WALLS UNTIL THE WALL HAS REACHED 65% OF DESIGN STRENGTH, FRAMED SLAB BEARING ON WALLS IS CAST, OR TEMPORARY WALL BRACING HAS BEEN PLACED.
AutoCAD SHX Text FOOTING STEPS SHALL BE NO STEEPER THAN ONE VERTICAL TO TWO HORIZONTAL, UNLESS NOTED.
AutoCAD SHX Text SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING. FOUNDATIONS POURED AGAINST THE EARTH REQUIRE THE FOLLOWING PRECAUTIONS: SLOPE SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING BEFORE AND DURING CONCRETE PLACEMENT.
AutoCAD SHX Text 2.04
AutoCAD SHX Text 2.05
AutoCAD SHX Text 2.03
AutoCAD SHX Text %%u2.00 FOUNDATIONS AND SLAB-ON-GROUND
AutoCAD SHX Text 2.02
AutoCAD SHX Text 2.01
AutoCAD SHX Text
CHAMFER OR ROUND ALL EXPOSED CORNERS MINIMUM 3/4".
AutoCAD SHX Text
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
AutoCAD SHX Text %%u3.00 REINFORCED CONCRETE
AutoCAD SHX Text
UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL WEIGHT AND
AutoCAD SHX Text USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IN CONCRETE IS NOT PERMITTED.
AutoCAD SHX Text THE PROPOSED MATERIALS AND MIX DESIGNS SHALL BE FULLY DOCUMENTED AND REVIEWED BY THE OWNER'S TESTING LABORATORY AND THE STRUCTURAL ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING THE REQUIRED DESIGN STRENGTH.
AutoCAD SHX Text ALL CONCRETE WORK SHALL CONFORM TO ACI 301-16, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. DESIGN IS BASED ON ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE.
AutoCAD SHX Text
HAVE THE FOLLOWING MINIMUM 28-DAY COMPRESSIVE STRENGTHS:
AutoCAD SHX Text DETAIL CONCRETE REINFORCEMENT AND ACCESSORIES IN ACCORDANCE WITH ACI 315R-18 GUIDE TO PRESENTING REINFORCING STEEL DESIGN DETAILS. SUBMIT SHOP DRAWINGS FOR APPROVAL, SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS FOR PLACING REINFORCING STEEL AND ACCESSORIES. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND REVIEWED.
AutoCAD SHX Text TIE ALL REINFORCING STEEL AND EMBEDMENTS SECURELY IN PLACE PRIOR TO PLACING CONCRETE. PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THE POSITION OF REINFORCEMENT WITHIN SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. "STICKING" DOWELS INTO WET CONCRETE IS NOT PERMITTED.
AutoCAD SHX Text PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE; SPLICE ONLY AS SHOWN OR APPROVED. STAGGER SPLICES WHERE POSSIBLE. USE TENSION SPLICE (CLASS "B") UNLESS NOTED OTHERWISE. DOWELS SHALL MATCH THE SIZE AND SPACING OF THE SPECIFIED REINFORCEMENT AND SHALL BE LAPPED WITH TENSION SPLICES (CLASS "B") UNLESS NOTED OTHERWISE.
AutoCAD SHX Text
REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE.
AutoCAD SHX Text 3.07
AutoCAD SHX Text 3.08
AutoCAD SHX Text 3.10
AutoCAD SHX Text 3.09
AutoCAD SHX Text 3.11
AutoCAD SHX Text 3.06
AutoCAD SHX Text 3.02
AutoCAD SHX Text 3.01
AutoCAD SHX Text 3.04
AutoCAD SHX Text 3.03
AutoCAD SHX Text 3.05
AutoCAD SHX Text
SLAB-ON-GRADE AND FOUNDATIONS
AutoCAD SHX Text
3,000 PSI
AutoCAD SHX Text
100 PSF
AutoCAD SHX Text THE DESIGN OF FOUNDATIONS IS BASED ON AN ASSUMED ALLOWABLE SOIL BEARING PRESSURE OF 1,500 PSF.
AutoCAD SHX Text PRE-FABRICATED GALVANIZED METAL RAILING W/ MIN. 2" DIA. POSTS @ 48" OC MAX., W/ 12" MIN. EMBED. IN PRE-ENGINEERED SLEEVE-IT SYSTEM (OR APPROVED EQUAL)
AutoCAD SHX Text
TOP OF WALL SLOPES, SEE CIVIL DWG.S
AutoCAD SHX Text 6"
AutoCAD SHX Text
1'-0" MIN.
AutoCAD SHX Text 1'-3"
AutoCAD SHX Text
"H" 6'-0" MAX.
AutoCAD SHX Text
3'-0" IF "H" IS LESS THAN 4'-0" 4'-4" IF "H" IS GREATER THAN 4'-0"
AutoCAD SHX Text 8"
AutoCAD SHX Text
2" CLR.
AutoCAD SHX Text DOWEL REINFORCING - #5 @ 12" OC IF "H" IS #5 @ 12" OC IF "H" IS LESS THAN 4'-0" - #6 @ 12" OC IF "H" IS #6 @ 12" OC IF "H" IS GREATER THAN 4'-0"
AutoCAD SHX Text
#5 @ 16" OC HORIZ.
AutoCAD SHX Text
3" CLR.
AutoCAD SHX Text
#5 @ 12" OC
AutoCAD SHX Text
2 #5 CONT. @ 3" OC AT TOP OF WALL
AutoCAD SHX Text
5 #5 CONT.
AutoCAD SHX Text
CONT. KEY
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
RETAINING WALL
AutoCAD SHX Text
AT GYM ENTRY RAMP
AutoCAD SHX Text 3/4" = 1'-0"
AutoCAD SHX Text 10"
AutoCAD SHX Text 8"
AutoCAD SHX Text
EQ.
AutoCAD SHX Text
EQ.
AutoCAD SHX Text
KEY NOT REQ'D IF "H" IS LESS THAN 2'-6"
AutoCAD SHX Text 4" THICK RAMP SLAB W/ 6x6-W2.9xW2.9 WWF
AutoCAD SHX Text #4 x 24" @ 18" OC, DRILL & EPOXY TO WALL W/ SIMPSON SET-3G (4" EMBED.)