4_ REVISED SPECIFICATION_Musco Lighting _ Amb.pdf

PDF 7 MB Posted

Attached to
2025-002 INODIC GRANTS PARK IMPROVEMENT PROJECTS
Solicitation number
PE-72600-NONST-2025-000000017
Issued by
Talbot County, Georgia

About this file

This document is a project specification related to an Ambucs Park improvement project in Griffin, Georgia, which is being administered by the state of Georgia and Talbot County. The project involves upgrading an existing youth sports facility with five baseball fields, a gymnasium, pavilions, and other facilities. Key components include regrading and upgrading the baseball fields, upgrading the gymnasium, installing new walkways, bleachers, batting cages, dugouts, lighting, and stormwater infrastructure. Additionally, the project will include seven new parking spaces. The overall scope also covers improvements to a separate Volunteer Park facility with football and softball fields, new concession and restroom buildings, and other site upgrades.

The project has an estimated total load of 66.34 kW across the five baseball fields, with detailed luminaire and lighting specifications provided. Guaranteed average horizontal illumination levels are specified for each field, ranging from 20-30 footcandles. Spill light and vertical illuminance details are also included. The contract opportunity ID is 671630b820efbf3515017140, and responses are due by a date unspecified in the document.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT SUMMARY

Not to be reproduced in whole or part without the wri en consent of Musco Sports Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

Ambucs Park Griffin, GA

Lighting System

Pole/Fixture Summary Pole ID Pole Height Mtg Height Fixture Qty Luminaire Type Load Circuit A1-A2 60' 60' 1 TLC-LED-900 0.88 kW A

60' 2 TLC-LED-550 1.08 kW A 16' 1 TLC-BT-575 0.57 kW A

A3-A4 60' 60' 1 TLC-LED-900 0.88 kW B 60' 2 TLC-LED-550 1.08 kW B 16' 1 TLC-BT-575 0.57 kW B

A5-A6 70' 70' 3 TLC-LED-900 2.64 kW C 16' 1 TLC-BT-575 0.57 kW C

A7-A8 60' 60' 3 TLC-LED-550 1.62 kW D 16' 1 TLC-BT-575 0.57 kW D

A9-A10 50' 50' 1 TLC-LED-550 0.54 kW E 50' 3 TLC-LED-900 2.64 kW E

B1-B2 70' 70' 1 TLC-LED-550 0.54 kW A 70' 3 TLC-LED-900 2.64 kW A 16' 1 TLC-BT-575 0.57 kW A

B3-B4 70' 70' 4 TLC-LED-900 3.52 kW B 16' 1 TLC-BT-575 0.57 kW B

B5-B6 70' 70' 4 TLC-LED-900 3.52 kW C B7-B8 70' 70' 1 TLC-LED-1200 1.17 kW D

70' 3 TLC-LED-900 2.64 kW D 16' 1 TLC-BT-575 0.57 kW D

C1-C2 70' 70' 1 TLC-LED-550 0.54 kW C 70' 3 TLC-LED-900 2.64 kW C 16' 1 TLC-BT-575 0.57 kW C

20 88 66.34 kW

Circuit Summary Circuit Description Load Fixture Qty

A Field 1 12.58 kW 18 B Field 2 13.26 kW 18 C Field 3 20.98 kW 26 D Field 4 13.16 kW 18 E Field 5 6.36 kW 8

Fixture Type Summary Type Source Wattage Lumens L90 L80 L70 Quantity

TLC-BT-575 LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 16

TLC-LED-1200 LED 5700K - 75 CRI 1170W 150,000 >120,000 >120,000 >120,000 2

TLC-LED-550 LED 5700K - 75 CRI 540W 67,000 >120,000 >120,000 >120,000 20

TLC-LED-900 LED 5700K - 75 CRI 880W 104,000 >120,000 >120,000 >120,000 50

Single Luminaire Amperage Draw Chart Driver Speci ca ons

(.90 min power factor) Line Amperage Per Luminaire

(max draw)

Single Phase Voltage 208 (60)

(60)

(60)

(60)

(60)

(60)

(60)

TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5

TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0

TLC-LED-550 3.2 3.0 2.8 2.4 1.9 1.8 1.4

TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

Ambucs Park Griffin, GA

Light Level Summary

Calculation Grid Summary Grid Name Calculation Metric Illumination Circuits Fixture

QtyAve Min Max Max/Min Ave/Min Field 1 (Infield) Horizontal Illuminance 33.74 24 39 1.65 1.42 A 18

Field 1 (Outfield) Horizontal Illuminance 23.38 18 32 1.82 1.33 A 18 Field 1 Spill Horizontal Illuminance 0.0039 0.00 0.02 - - A 18 Field 1 Spill Max Candela Metric 349.3167 0.00 1611.38 - - A 18 Field 1 Spill Max Vertical Illuminance Metric 0.0105 0.00 0.04 - - A 18

Field 2 (Infield) Horizontal Illuminance 34.69 24 41 1.68 1.44 B 18 Field 2 (Outfield) Horizontal Illuminance 22.53 18 30 1.70 1.27 B 18

Field 2 Spill Horizontal Illuminance 0.0035 0.00 0.01 - - B 18 Field 2 Spill Max Candela Metric 1803.6656 4.57 10370.38 2271.444 395.060 B 18 Field 2 Spill Max Vertical Illuminance Metric 0.0162 0.00 0.07 - - B 18

Field 3 (Infield) Horizontal Illuminance 31.45 26 39 1.52 1.23 C 26 Field 3 (Outfield) Horizontal Illuminance 22.64 16 29 1.85 1.42 C 26

Field 3 Spill Horizontal Illuminance 0.0012 0.00 0.01 - - C 26 Field 3 Spill Max Candela Metric 248.9704 0.68 3407.48 4999.693 365.306 C 26 Field 3 Spill Max Vertical Illuminance Metric 0.0043 0.00 0.04 - - C 26

Field 4 (Infield) Horizontal Illuminance 33.54 25 40 1.62 1.35 D 18 Field 4 (Outfield) Horizontal Illuminance 23.76 18 32 1.82 1.35 D 18

Field 4 Spill Horizontal Illuminance 0.0065 0.00 0.04 - - D 18 Field 4 Spill Max Candela Metric 804.0971 0.00 3752.80 - - D 18 Field 4 Spill Max Vertical Illuminance Metric 0.0197 0.00 0.11 - - D 18

Field 5 (Infield) Horizontal Illuminance 34.22 20 42 2.04 1.68 E 8 Field 5 (Outfield) Horizontal Illuminance 22.30 12 36 3.09 1.93 E 8

Field 5 Spill Horizontal Illuminance 0.0001 0.00 0.00 - - E 8 Field 5 Spill Max Candela Metric 12.9798 0.00 96.52 - - E 8 Field 5 Spill Max Vertical Illuminance Metric 0.0004 0.00 0.00 - - E 8

ILLUMINATION SUMMARY

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

18 30

35'

30'

5'

185'

' 45'

W

VW

V

SCALE IN FEET 1 : 40

0' 40' 80'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A1-A2 60' - 60' TLC-LED-550 2 2 0

60' TLC-LED-900 1 1 0

15.5' TLC-BT-575 1 1 0

2 B1-B2 70' - 70' TLC-LED-550 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 1

Size 175'/180'/180' - basepath 60' Spacing 20.0' x 20.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Infield Outfield Guaranteed Average 30 20

Scan Average 33.74 23.38 Maximum 39 32 Minimum 24 18

Avg/Min 1.42 1.33 Guaranteed Max/Min 2.5 3

Max/Min 1.65 1.82 UG (adjacent pts) 1.29 1.38

CU 0.60

No. of Points 25 55

LUMINAIRE INFORMATION

Applied Circuits A

No. of Luminaires 18 Total Load 12.58 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights for players to see the ball within the air

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B3 B4

A3 A4

205'

' 10'

5'

40'

' 40'

EM

SCALE IN FEET 1 : 40

0' 40' 80'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A3-A4 60' - 60' TLC-LED-550 2 2 0

60' TLC-LED-900 1 1 0

15.5' TLC-BT-575 1 1 0

2 B3-B4 70' - 70' TLC-LED-900 4 4 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 2

Size 195'/198'/191' - basepath 60' Spacing 20.0' x 20.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Infield Outfield Guaranteed Average 30 20

Scan Average 34.69 22.53 Maximum 41 30 Minimum 24 18

Avg/Min 1.44 1.27 Guaranteed Max/Min 2.5 3

Max/Min 1.68 1.70 UG (adjacent pts) 1.29 1.47

CU 0.64

No. of Points 25 68

LUMINAIRE INFORMATION

Applied Circuits B

No. of Luminaires 18 Total Load 13.26 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

EM

\pxqc;GATE

C1

C2

A5

A6

B5

B6

30'

153'

93'

258'

50'

30'

151'

24'

30'

50'

248'

92'

SCALE IN FEET 1 : 60

0' 60' 120'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A5-A6 70' - 70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

2 B5-B6 70' - 70' TLC-LED-900 4 4 0

2 C1-C2 70' - 70' TLC-LED-550 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

6 Totals 26 26 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 3

Size 258'/268'/275' - basepath 90' Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Infield Outfield Guaranteed Average 30 20

Scan Average 31.45 22.64 Maximum 39 29 Minimum 26 16

Avg/Min 1.23 1.42 Guaranteed Max/Min 2.5 3

Max/Min 1.52 1.85 UG (adjacent pts) 1.32 1.61

CU 0.78

No. of Points 25 55

LUMINAIRE INFORMATION

Applied Circuits C

No. of Luminaires 26 Total Load 20.98 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

A7

A8

B7

B8

30'

35'

5'

10'

'185'

\pxqc;CHAINLINK FENCE

SCALE IN FEET 1 : 40

0' 40' 80'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A7-A8 60' - 60' TLC-LED-550 3 3 0

15.5' TLC-BT-575 1 1 0

2 B7-B8 70' - 70' TLC-LED-1200 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 4

Size 200'/200'/183' - basepath 60' Spacing 20.0' x 20.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Infield Outfield Guaranteed Average 30 20

Scan Average 33.54 23.76 Maximum 40 32 Minimum 25 18

Avg/Min 1.35 1.35 Guaranteed Max/Min 2.5 3

Max/Min 1.62 1.82 UG (adjacent pts) 1.24 1.41

CU 0.64

No. of Points 25 67

LUMINAIRE INFORMATION

Applied Circuits D

No. of Luminaires 18 Total Load 13.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

A9

A10

40'

30'

SCALE IN FEET 1 : 30

0' 30' 60'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A9-A10 50' - 50' TLC-LED-550 1 1 0

50' TLC-LED-900 3 3 0

2 Totals 8 8 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 5

Size 125'/135'/125' - basepath 50' Spacing 20.0' x 20.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Infield Outfield Guaranteed Average 30 -

Scan Average 34.22 22.30 Maximum 42 36 Minimum 20 12

Avg/Min 1.68 1.93 Max/Min 2.04 3.09

UG (adjacent pts) 1.37 1.54

CU 0.67

No. of Points 24 19

LUMINAIRE INFORMATION

Applied Circuits E No. of Luminaires 8

Total Load 6.36 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

0.01

0.01

0.01

0.02

0.02

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00 0.00

0.00 0.000.000.000.000.000.01

0.01 0.01

0.01 0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00 0.00

0.00 0.00 0.01 0.02 0.02 0.01 0.01 0.00 0.00 0.01 0.01

0.01

0.01

0.00

0.00

B3 B4

A3 A4

A7

A8

B7

A9 A10

EM

EM

W

VW

V

SCALE IN FEET 1 : 80

0' 80' 160'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A1-A2 60' - 60' TLC-LED-550 2 2 0

60' TLC-LED-900 1 1 0

15.5' TLC-BT-575 1 1 0

2 B1-B2 70' - 70' TLC-LED-550 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 1 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average 0.0039

Maximum 0.02 Minimum 0.00

CU 0.00

No. of Points 53

LUMINAIRE INFORMATION

Applied Circuits A

No. of Luminaires 18 Total Load 12.58 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

0.02

0.03

0.04

0.04

0.04

0.01

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00 0.00

0.00 0.000.000.000.000.010.02

0.02 0.02

0.02 0.01

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00 0.00

0.00 0.00 0.02 0.04 0.04 0.03 0.02 0.01 0.01 0.02 0.02

0.03

0.02

0.01

0.01

B3 B4

A3 A4

A7

A8

B7

A9 A10

EM

EM

W

VW

V

SCALE IN FEET 1 : 80

0' 80' 160'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A1-A2 60' - 60' TLC-LED-550 2 2 0

60' TLC-LED-900 1 1 0

15.5' TLC-BT-575 1 1 0

2 B1-B2 70' - 70' TLC-LED-550 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 1 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED MAX VERTICAL FOOTCANDLES

Entire Grid Scan Average 0.0105

Maximum 0.04 Minimum 0.00

CU 0.00

No. of Points 53

LUMINAIRE INFORMATION

Applied Circuits A

No. of Luminaires 18 Total Load 12.58 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

258118174357

72 381 920 1092 1094 998 659 333 313

B3 B4

A3 A4

A7

A8

B7

A9 A10

EM

EM

W

VW

V

SCALE IN FEET 1 : 80

0' 80' 160'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A1-A2 60' - 60' TLC-LED-550 2 2 0

60' TLC-LED-900 1 1 0

15.5' TLC-BT-575 1 1 0

2 B1-B2 70' - 70' TLC-LED-550 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 1 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED CANDELA (PER FIXTURE)

Entire Grid Scan Average 349.3167

Maximum 1611.38 Minimum 0.00

CU 0.00

No. of Points 53

LUMINAIRE INFORMATION

Applied Circuits A

No. of Luminaires 18 Total Load 12.58 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 00.0

00.0 00.0

00.0 00.0

00.0 00.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 1 0.0

1 0.0 1 0.0

B3 B4

A3 A4

A7

A8

B7

A9A10

EM

EM

W

VW

V

\pxqc;GATE

\pxqc;GATE20

C1

C2

A5

A6

B5

B6

SCALE IN FEET 1 : 100

0' 100' 200'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A3-A4 60' - 60' TLC-LED-550 2 2 0

60' TLC-LED-900 1 1 0

15.5' TLC-BT-575 1 1 0

2 B3-B4 70' - 70' TLC-LED-900 4 4 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 2 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average 0.0035

Maximum 0.01 Minimum 0.00

CU 0.00

No. of Points 55

LUMINAIRE INFORMATION

Applied Circuits B

No. of Luminaires 18 Total Load 13.26 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 00.0

00.0 00.0

00.0 00.0

00.0 20.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 5 0.0

4 0.0 3 0.0

B3 B4

A3 A4

A7

A8

B7

A9A10

EM

EM

W

VW

V

\pxqc;GATE

\pxqc;GATE20

C1

C2

A5

A6

B5

B6

SCALE IN FEET 1 : 100

0' 100' 200'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A3-A4 60' - 60' TLC-LED-550 2 2 0

60' TLC-LED-900 1 1 0

15.5' TLC-BT-575 1 1 0

2 B3-B4 70' - 70' TLC-LED-900 4 4 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 2 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED MAX VERTICAL FOOTCANDLES

Entire Grid Scan Average 0.0162

Maximum 0.07 Minimum 0.00

CU 0.00

No. of Points 55

LUMINAIRE INFORMATION

Applied Circuits B

No. of Luminaires 18 Total Load 13.26 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

41 20

47 57

B3 B4

A3 A4

A7

A8

B7

A9A10

EM

EM

W

VW

V

\pxqc;GATE

\pxqc;GATE20

C1

C2

A5

A6

B5

B6

SCALE IN FEET 1 : 100

0' 100' 200'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A3-A4 60' - 60' TLC-LED-550 2 2 0

60' TLC-LED-900 1 1 0

15.5' TLC-BT-575 1 1 0

2 B3-B4 70' - 70' TLC-LED-900 4 4 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 2 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED CANDELA (PER FIXTURE)

Entire Grid Scan Average 1803.6656

Maximum 10370.38 Minimum 4.57

CU 0.00

No. of Points 55

LUMINAIRE INFORMATION

Applied Circuits B

No. of Luminaires 18 Total Load 13.26 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B2

A2

B3 B4

A3 A4

A7

A8

B7

B8

A9A10

EM

\pxqc;GATE

\pxqc;GATE

\pxqc;CHAINLINK FENCE

C1

C2

A5

A6

B5

B6

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00 0.00

0.00 0.01 0.00 0.00 0.00

0.00 0.00

0.00 0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.01

0.00

0.00

0.01

0.01

0.00 0.00

0.00 0.000.000.000.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

SCALE IN FEET 1 : 100

0' 100' 200'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A5-A6 70' - 70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

2 B5-B6 70' - 70' TLC-LED-900 4 4 0

2 C1-C2 70' - 70' TLC-LED-550 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

6 Totals 26 26 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 3 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average 0.0012

Maximum 0.01 Minimum 0.00

CU 0.00

No. of Points 63

LUMINAIRE INFORMATION

Applied Circuits C

No. of Luminaires 26 Total Load 20.98 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B2

A2

B3 B4

A3 A4

A7

A8

B7

B8

A9A10

EM

\pxqc;GATE

\pxqc;GATE

\pxqc;CHAINLINK FENCE

C1

C2

A5

A6

B5

B6

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00 0.00

0.01 0.02 0.00 0.01 0.01

0.01 0.00

0.00 0.00

0.01

0.01

0.00

0.00

0.00

0.00

0.00

0.01

0.01

0.02

0.04

0.00

0.01

0.01

0.01

0.01 0.00

0.00 0.010.000.000.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.01

0.00

0.00

0.00

0.01

0.00

SCALE IN FEET 1 : 100

0' 100' 200'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A5-A6 70' - 70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

2 B5-B6 70' - 70' TLC-LED-900 4 4 0

2 C1-C2 70' - 70' TLC-LED-550 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

6 Totals 26 26 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 3 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED MAX VERTICAL FOOTCANDLES

Entire Grid Scan Average 0.0043

Maximum 0.04 Minimum 0.00

CU 0.00

No. of Points 63

LUMINAIRE INFORMATION

Applied Circuits C

No. of Luminaires 26 Total Load 20.98 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B2

A2

B3 B4

A3 A4

A7

A8

B7

B8

A9A10

EM

\pxqc;GATE

\pxqc;GATE

\pxqc;CHAINLINK FENCE

C1

C2

A5

A6

B5

B6

291 1588 98

1035325

SCALE IN FEET 1 : 100

0' 100' 200'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A5-A6 70' - 70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

2 B5-B6 70' - 70' TLC-LED-900 4 4 0

2 C1-C2 70' - 70' TLC-LED-550 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

6 Totals 26 26 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 3 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED CANDELA (PER FIXTURE)

Entire Grid Scan Average 248.9704

Maximum 3407.48 Minimum 0.68

CU 0.00

No. of Points 63

LUMINAIRE INFORMATION

Applied Circuits C

No. of Luminaires 26 Total Load 20.98 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

B3 B4

A3 A4

A7

A8

B7

B8

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00 0.00 0.00 0.00

0.00

0.00

0.00

0.00

0.01

0.02

0.04

0.03

0.02

0.02

0.02

0.01

0.01

0.01

0.01

0.02

0.02

0.04

0.03

0.02

0.00

0.00

0.00

0.00 0.00

0.000.000.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00

0.00

0.01

0.00

0.00 0.00

0.00

A9A10

EM

W V

EM

W

VW

V

\pxqc;GATE

\pxqc;GATE

\pxqc;CHAINLINK FENCE

C1

C2

A5

A6

B5

B6

SCALE IN FEET 1 : 100

0' 100' 200'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A7-A8 60' - 60' TLC-LED-550 3 3 0

15.5' TLC-BT-575 1 1 0

2 B7-B8 70' - 70' TLC-LED-1200 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 4 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average 0.0065

Maximum 0.04 Minimum 0.00

CU 0.00

No. of Points 55

LUMINAIRE INFORMATION

Applied Circuits D

No. of Luminaires 18 Total Load 13.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

B3 B4

A3 A4

A7

A8

B7

B8

0.00 0.00

0.00 0.00

0.01 0.00

0.00 0.00 0.00 0.00 0.00

0.00

0.00

0.00

0.00

0.03

0.06

0.11

0.09

0.08

0.07

0.06

0.05

0.02

0.03

0.05

0.06

0.07

0.11

0.07

0.04

0.01

0.00

0.00

0.00 0.00

0.000.000.00 0.00

0.00 0.00

0.01 0.01

0.00 0.00

0.00 0.00

0.00

0.01

0.02

0.01

0.01 0.00

0.00

A9A10

EM

W V

EM

W

VW

V

\pxqc;GATE

\pxqc;GATE

\pxqc;CHAINLINK FENCE

C1

C2

A5

A6

B5

B6

SCALE IN FEET 1 : 100

0' 100' 200'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A7-A8 60' - 60' TLC-LED-550 3 3 0

15.5' TLC-BT-575 1 1 0

2 B7-B8 70' - 70' TLC-LED-1200 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 4 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED MAX VERTICAL FOOTCANDLES

Entire Grid Scan Average 0.0197

Maximum 0.11 Minimum 0.00

CU 0.00

No. of Points 55

LUMINAIRE INFORMATION

Applied Circuits D

No. of Luminaires 18 Total Load 13.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

B2

A1

A2

B3 B4

A3 A4

A7

A8

B7

B8

0 0 0

A9A10

EM

W V

EM

W

VW

V

\pxqc;GATE

\pxqc;GATE

\pxqc;CHAINLINK FENCE

C1

C2

A5

A6

B5

B6

SCALE IN FEET 1 : 100

0' 100' 200'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A7-A8 60' - 60' TLC-LED-550 3 3 0

15.5' TLC-BT-575 1 1 0

2 B7-B8 70' - 70' TLC-LED-1200 1 1 0

70' TLC-LED-900 3 3 0

15.5' TLC-BT-575 1 1 0

4 Totals 18 18 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 4 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED CANDELA (PER FIXTURE)

Entire Grid Scan Average 804.0971

Maximum 3752.80 Minimum 0.00

CU 0.00

No. of Points 55

LUMINAIRE INFORMATION

Applied Circuits D

No. of Luminaires 18 Total Load 13.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

A1

A2

A3 A4

A7

A8

B7

B8

A9 A10

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 0 0.0

0 0.0 0 0.0

0 0.0 0 0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 00.0

00.0

0.0

0.0

0.0

0.0

EM

EM

\pxqc;CHAINLINK FENCE

A5

A6

B6

SCALE IN FEET 1 : 80

0' 80' 160'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A9-A10 50' - 50' TLC-LED-550 1 1 0

50' TLC-LED-900 3 3 0

2 Totals 8 8 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 5 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average 0.0001

Maximum 0.00 Minimum 0.00

CU 0.00

No. of Points 47

LUMINAIRE INFORMATION

Applied Circuits E

No. of Luminaires 8 Total Load 6.36 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

A1

A2

A3 A4

A7

A8

B7

B8

A9 A10

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 0 0.0

0 0.0 0 0.0

0 0.0 0 0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0 00.0

00.0

0.0

0.0

0.0

0.0

EM

EM

\pxqc;CHAINLINK FENCE

A5

A6

B6

SCALE IN FEET 1 : 80

0' 80' 160'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A9-A10 50' - 50' TLC-LED-550 1 1 0

50' TLC-LED-900 3 3 0

2 Totals 8 8 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 5 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED MAX VERTICAL FOOTCANDLES

Entire Grid Scan Average 0.0004

Maximum 0.00 Minimum 0.00

CU 0.00

No. of Points 47

LUMINAIRE INFORMATION

Applied Circuits E

No. of Luminaires 8 Total Load 6.36 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

B1

A1

A2

A3 A4

A7

A8

B7

B8

A9 A10

21 37 63 7 1

787897

EM

EM

\pxqc;CHAINLINK FENCE

A5

A6

B6

SCALE IN FEET 1 : 80

0' 80' 160'

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE GRADE

LEVEL LUMINAIRE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 A9-A10 50' - 50' TLC-LED-550 1 1 0

50' TLC-LED-900 3 3 0

2 Totals 8 8 0

*Above Grade level relative to the field

Ambucs Park Griffin, GA

Grid Summary Name Field 5 Spill

Spacing 30.0' x 30.0' Height 3.0' above grade

Illumination Summary

MAINTAINED CANDELA (PER FIXTURE)

Entire Grid Scan Average 12.9798

Maximum 96.52 Minimum 0.00

CU 0.00

No. of Points 47

LUMINAIRE INFORMATION

Applied Circuits E

No. of Luminaires 8 Total Load 6.36 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.

Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures

EQUIPMENT LAYOUT

Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24

Ambucs Park Griffin, GA

Field 1175'/180'/180' - basepath 60'

B1

B2

A1

A2

Fiel d 2

5'/

8'/

1'

- b as ep ath

B3

B4

A3

A4

A7

A8

B7

B8

Field 4

200'/200'/183' - basepath 60'

Field

5'/

5'/

5'

- b as ep ath

A9

A10

EM

W V

EM

W

VW

V

\pxqc;GATE

\pxqc;GATE

\pxqc;CHAINLINK FENCE

Field 3

258'/268'/275' - b asepath 90'

C1

C2

A5

A6

B5

B6

SCALE IN FEET 1 : 150

0' 150' 300' Pole location(s) dimensions are relative to 0,0 reference point(s)

Equipment Layout

INCLUDES:

· Field 1

· Field 2

· Field 3

· Field 4

· Field 5 Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

Equipment List For Areas Shown Pole Luminaires

QTY LOCATION SIZE GRADE

ELEVATION

ABOVE

GRADE LEVEL LUMINAIRE TYPE QTY/POLE

4 A1-A4 60' - 60' TLC-LED-550 2

60' TLC-LED-900 1

15.5' TLC-BT-575 1

2 A5-A6 70' - 70' TLC-LED-900 3

15.5' TLC-BT-575 1

2 A7-A8 60' - 60' TLC-LED-550 3

15.5' TLC-BT-575 1

2 A9-A10 50' - 50' TLC-LED-550 1

50' TLC-LED-900 3

4 B1-B2

C1-C2 70' - 70' TLC-LED-550 1

70' TLC-LED-900 3

15.5' TLC-BT-575 1

2 B3-B4 70' - 70' TLC-LED-900 4

15.5' TLC-BT-575 1

2 B5-B6 70' - 70' TLC-LED-900 4

2 B7-B8 70' - 70' TLC-LED-1200 1

70' TLC-LED-900 3

15.5' TLC-BT-575 1

20 Totals 88

Single Luminaire Amperage Draw Chart Driver Speci ca ons

(.90 min power factor) Line Amperage Per Luminaire

(max draw)

Single Phase Voltage 208 (60)

(60)

(60)

(60)

(60)

(60)

(60)

TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5

TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0

TLC-LED-550 3.2 3.0 2.8 2.4 1.9 1.8 1.4

TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3

File details come from the government source that posted it. Updated .