4_ REVISED SPECIFICATION_Musco Lighting _ Amb.pdf
PDF 7 MB Posted
- Attached to
- 2025-002 INODIC GRANTS PARK IMPROVEMENT PROJECTS
- Solicitation number
- PE-72600-NONST-2025-000000017
- Issued by
- Talbot County, Georgia
About this file
This document is a project specification related to an Ambucs Park improvement project in Griffin, Georgia, which is being administered by the state of Georgia and Talbot County. The project involves upgrading an existing youth sports facility with five baseball fields, a gymnasium, pavilions, and other facilities. Key components include regrading and upgrading the baseball fields, upgrading the gymnasium, installing new walkways, bleachers, batting cages, dugouts, lighting, and stormwater infrastructure. Additionally, the project will include seven new parking spaces. The overall scope also covers improvements to a separate Volunteer Park facility with football and softball fields, new concession and restroom buildings, and other site upgrades.
The project has an estimated total load of 66.34 kW across the five baseball fields, with detailed luminaire and lighting specifications provided. Guaranteed average horizontal illumination levels are specified for each field, ranging from 20-30 footcandles. Spill light and vertical illuminance details are also included. The contract opportunity ID is 671630b820efbf3515017140, and responses are due by a date unspecified in the document.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT SUMMARY
Not to be reproduced in whole or part without the wri en consent of Musco Sports Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
Ambucs Park Griffin, GA
Lighting System
Pole/Fixture Summary Pole ID Pole Height Mtg Height Fixture Qty Luminaire Type Load Circuit A1-A2 60' 60' 1 TLC-LED-900 0.88 kW A
60' 2 TLC-LED-550 1.08 kW A 16' 1 TLC-BT-575 0.57 kW A
A3-A4 60' 60' 1 TLC-LED-900 0.88 kW B 60' 2 TLC-LED-550 1.08 kW B 16' 1 TLC-BT-575 0.57 kW B
A5-A6 70' 70' 3 TLC-LED-900 2.64 kW C 16' 1 TLC-BT-575 0.57 kW C
A7-A8 60' 60' 3 TLC-LED-550 1.62 kW D 16' 1 TLC-BT-575 0.57 kW D
A9-A10 50' 50' 1 TLC-LED-550 0.54 kW E 50' 3 TLC-LED-900 2.64 kW E
B1-B2 70' 70' 1 TLC-LED-550 0.54 kW A 70' 3 TLC-LED-900 2.64 kW A 16' 1 TLC-BT-575 0.57 kW A
B3-B4 70' 70' 4 TLC-LED-900 3.52 kW B 16' 1 TLC-BT-575 0.57 kW B
B5-B6 70' 70' 4 TLC-LED-900 3.52 kW C B7-B8 70' 70' 1 TLC-LED-1200 1.17 kW D
70' 3 TLC-LED-900 2.64 kW D 16' 1 TLC-BT-575 0.57 kW D
C1-C2 70' 70' 1 TLC-LED-550 0.54 kW C 70' 3 TLC-LED-900 2.64 kW C 16' 1 TLC-BT-575 0.57 kW C
20 88 66.34 kW
Circuit Summary Circuit Description Load Fixture Qty
A Field 1 12.58 kW 18 B Field 2 13.26 kW 18 C Field 3 20.98 kW 26 D Field 4 13.16 kW 18 E Field 5 6.36 kW 8
Fixture Type Summary Type Source Wattage Lumens L90 L80 L70 Quantity
TLC-BT-575 LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 16
TLC-LED-1200 LED 5700K - 75 CRI 1170W 150,000 >120,000 >120,000 >120,000 2
TLC-LED-550 LED 5700K - 75 CRI 540W 67,000 >120,000 >120,000 >120,000 20
TLC-LED-900 LED 5700K - 75 CRI 880W 104,000 >120,000 >120,000 >120,000 50
Single Luminaire Amperage Draw Chart Driver Speci ca ons
(.90 min power factor) Line Amperage Per Luminaire
(max draw)
Single Phase Voltage 208 (60)
(60)
(60)
(60)
(60)
(60)
(60)
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0
TLC-LED-550 3.2 3.0 2.8 2.4 1.9 1.8 1.4
TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
Ambucs Park Griffin, GA
Light Level Summary
Calculation Grid Summary Grid Name Calculation Metric Illumination Circuits Fixture
QtyAve Min Max Max/Min Ave/Min Field 1 (Infield) Horizontal Illuminance 33.74 24 39 1.65 1.42 A 18
Field 1 (Outfield) Horizontal Illuminance 23.38 18 32 1.82 1.33 A 18 Field 1 Spill Horizontal Illuminance 0.0039 0.00 0.02 - - A 18 Field 1 Spill Max Candela Metric 349.3167 0.00 1611.38 - - A 18 Field 1 Spill Max Vertical Illuminance Metric 0.0105 0.00 0.04 - - A 18
Field 2 (Infield) Horizontal Illuminance 34.69 24 41 1.68 1.44 B 18 Field 2 (Outfield) Horizontal Illuminance 22.53 18 30 1.70 1.27 B 18
Field 2 Spill Horizontal Illuminance 0.0035 0.00 0.01 - - B 18 Field 2 Spill Max Candela Metric 1803.6656 4.57 10370.38 2271.444 395.060 B 18 Field 2 Spill Max Vertical Illuminance Metric 0.0162 0.00 0.07 - - B 18
Field 3 (Infield) Horizontal Illuminance 31.45 26 39 1.52 1.23 C 26 Field 3 (Outfield) Horizontal Illuminance 22.64 16 29 1.85 1.42 C 26
Field 3 Spill Horizontal Illuminance 0.0012 0.00 0.01 - - C 26 Field 3 Spill Max Candela Metric 248.9704 0.68 3407.48 4999.693 365.306 C 26 Field 3 Spill Max Vertical Illuminance Metric 0.0043 0.00 0.04 - - C 26
Field 4 (Infield) Horizontal Illuminance 33.54 25 40 1.62 1.35 D 18 Field 4 (Outfield) Horizontal Illuminance 23.76 18 32 1.82 1.35 D 18
Field 4 Spill Horizontal Illuminance 0.0065 0.00 0.04 - - D 18 Field 4 Spill Max Candela Metric 804.0971 0.00 3752.80 - - D 18 Field 4 Spill Max Vertical Illuminance Metric 0.0197 0.00 0.11 - - D 18
Field 5 (Infield) Horizontal Illuminance 34.22 20 42 2.04 1.68 E 8 Field 5 (Outfield) Horizontal Illuminance 22.30 12 36 3.09 1.93 E 8
Field 5 Spill Horizontal Illuminance 0.0001 0.00 0.00 - - E 8 Field 5 Spill Max Candela Metric 12.9798 0.00 96.52 - - E 8 Field 5 Spill Max Vertical Illuminance Metric 0.0004 0.00 0.00 - - E 8
ILLUMINATION SUMMARY
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
18 30
35'
30'
5'
185'
' 45'
W
VW
V
SCALE IN FEET 1 : 40
0' 40' 80'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A1-A2 60' - 60' TLC-LED-550 2 2 0
60' TLC-LED-900 1 1 0
15.5' TLC-BT-575 1 1 0
2 B1-B2 70' - 70' TLC-LED-550 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 1
Size 175'/180'/180' - basepath 60' Spacing 20.0' x 20.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield Guaranteed Average 30 20
Scan Average 33.74 23.38 Maximum 39 32 Minimum 24 18
Avg/Min 1.42 1.33 Guaranteed Max/Min 2.5 3
Max/Min 1.65 1.82 UG (adjacent pts) 1.29 1.38
CU 0.60
No. of Points 25 55
LUMINAIRE INFORMATION
Applied Circuits A
No. of Luminaires 18 Total Load 12.58 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.
NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights for players to see the ball within the air
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B3 B4
A3 A4
205'
' 10'
5'
40'
' 40'
EM
SCALE IN FEET 1 : 40
0' 40' 80'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A3-A4 60' - 60' TLC-LED-550 2 2 0
60' TLC-LED-900 1 1 0
15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' TLC-LED-900 4 4 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 2
Size 195'/198'/191' - basepath 60' Spacing 20.0' x 20.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield Guaranteed Average 30 20
Scan Average 34.69 22.53 Maximum 41 30 Minimum 24 18
Avg/Min 1.44 1.27 Guaranteed Max/Min 2.5 3
Max/Min 1.68 1.70 UG (adjacent pts) 1.29 1.47
CU 0.64
No. of Points 25 68
LUMINAIRE INFORMATION
Applied Circuits B
No. of Luminaires 18 Total Load 13.26 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.
NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
EM
\pxqc;GATE
C1
C2
A5
A6
B5
B6
30'
153'
93'
258'
50'
30'
151'
24'
30'
50'
248'
92'
SCALE IN FEET 1 : 60
0' 60' 120'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A5-A6 70' - 70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
2 B5-B6 70' - 70' TLC-LED-900 4 4 0
2 C1-C2 70' - 70' TLC-LED-550 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
6 Totals 26 26 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 3
Size 258'/268'/275' - basepath 90' Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield Guaranteed Average 30 20
Scan Average 31.45 22.64 Maximum 39 29 Minimum 26 16
Avg/Min 1.23 1.42 Guaranteed Max/Min 2.5 3
Max/Min 1.52 1.85 UG (adjacent pts) 1.32 1.61
CU 0.78
No. of Points 25 55
LUMINAIRE INFORMATION
Applied Circuits C
No. of Luminaires 26 Total Load 20.98 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.
NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
A7
A8
B7
B8
30'
35'
5'
10'
'185'
\pxqc;CHAINLINK FENCE
SCALE IN FEET 1 : 40
0' 40' 80'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A7-A8 60' - 60' TLC-LED-550 3 3 0
15.5' TLC-BT-575 1 1 0
2 B7-B8 70' - 70' TLC-LED-1200 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 4
Size 200'/200'/183' - basepath 60' Spacing 20.0' x 20.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield Guaranteed Average 30 20
Scan Average 33.54 23.76 Maximum 40 32 Minimum 25 18
Avg/Min 1.35 1.35 Guaranteed Max/Min 2.5 3
Max/Min 1.62 1.82 UG (adjacent pts) 1.24 1.41
CU 0.64
No. of Points 25 67
LUMINAIRE INFORMATION
Applied Circuits D
No. of Luminaires 18 Total Load 13.16 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.
NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
A9
A10
40'
30'
SCALE IN FEET 1 : 30
0' 30' 60'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A9-A10 50' - 50' TLC-LED-550 1 1 0
50' TLC-LED-900 3 3 0
2 Totals 8 8 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 5
Size 125'/135'/125' - basepath 50' Spacing 20.0' x 20.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield Guaranteed Average 30 -
Scan Average 34.22 22.30 Maximum 42 36 Minimum 20 12
Avg/Min 1.68 1.93 Max/Min 2.04 3.09
UG (adjacent pts) 1.37 1.54
CU 0.67
No. of Points 24 19
LUMINAIRE INFORMATION
Applied Circuits E No. of Luminaires 8
Total Load 6.36 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.
NOTES: Trees near eld will have to be trimmed or removed in order to prevent any light blockage on the eld or for any uplights
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
0.01
0.01
0.01
0.02
0.02
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00 0.00
0.00 0.000.000.000.000.000.01
0.01 0.01
0.01 0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00 0.00
0.00 0.00 0.01 0.02 0.02 0.01 0.01 0.00 0.00 0.01 0.01
0.01
0.01
0.00
0.00
B3 B4
A3 A4
A7
A8
B7
A9 A10
EM
EM
W
VW
V
SCALE IN FEET 1 : 80
0' 80' 160'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A1-A2 60' - 60' TLC-LED-550 2 2 0
60' TLC-LED-900 1 1 0
15.5' TLC-BT-575 1 1 0
2 B1-B2 70' - 70' TLC-LED-550 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 1 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid Scan Average 0.0039
Maximum 0.02 Minimum 0.00
CU 0.00
No. of Points 53
LUMINAIRE INFORMATION
Applied Circuits A
No. of Luminaires 18 Total Load 12.58 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
0.02
0.03
0.04
0.04
0.04
0.01
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00 0.00
0.00 0.000.000.000.000.010.02
0.02 0.02
0.02 0.01
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00 0.00
0.00 0.00 0.02 0.04 0.04 0.03 0.02 0.01 0.01 0.02 0.02
0.03
0.02
0.01
0.01
B3 B4
A3 A4
A7
A8
B7
A9 A10
EM
EM
W
VW
V
SCALE IN FEET 1 : 80
0' 80' 160'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A1-A2 60' - 60' TLC-LED-550 2 2 0
60' TLC-LED-900 1 1 0
15.5' TLC-BT-575 1 1 0
2 B1-B2 70' - 70' TLC-LED-550 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 1 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED MAX VERTICAL FOOTCANDLES
Entire Grid Scan Average 0.0105
Maximum 0.04 Minimum 0.00
CU 0.00
No. of Points 53
LUMINAIRE INFORMATION
Applied Circuits A
No. of Luminaires 18 Total Load 12.58 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
258118174357
72 381 920 1092 1094 998 659 333 313
B3 B4
A3 A4
A7
A8
B7
A9 A10
EM
EM
W
VW
V
SCALE IN FEET 1 : 80
0' 80' 160'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A1-A2 60' - 60' TLC-LED-550 2 2 0
60' TLC-LED-900 1 1 0
15.5' TLC-BT-575 1 1 0
2 B1-B2 70' - 70' TLC-LED-550 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 1 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED CANDELA (PER FIXTURE)
Entire Grid Scan Average 349.3167
Maximum 1611.38 Minimum 0.00
CU 0.00
No. of Points 53
LUMINAIRE INFORMATION
Applied Circuits A
No. of Luminaires 18 Total Load 12.58 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 00.0
00.0 00.0
00.0 00.0
00.0 00.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 1 0.0
1 0.0 1 0.0
B3 B4
A3 A4
A7
A8
B7
A9A10
EM
EM
W
VW
V
\pxqc;GATE
\pxqc;GATE20
C1
C2
A5
A6
B5
B6
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A3-A4 60' - 60' TLC-LED-550 2 2 0
60' TLC-LED-900 1 1 0
15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' TLC-LED-900 4 4 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 2 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid Scan Average 0.0035
Maximum 0.01 Minimum 0.00
CU 0.00
No. of Points 55
LUMINAIRE INFORMATION
Applied Circuits B
No. of Luminaires 18 Total Load 13.26 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 00.0
00.0 00.0
00.0 00.0
00.0 20.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 5 0.0
4 0.0 3 0.0
B3 B4
A3 A4
A7
A8
B7
A9A10
EM
EM
W
VW
V
\pxqc;GATE
\pxqc;GATE20
C1
C2
A5
A6
B5
B6
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A3-A4 60' - 60' TLC-LED-550 2 2 0
60' TLC-LED-900 1 1 0
15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' TLC-LED-900 4 4 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 2 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED MAX VERTICAL FOOTCANDLES
Entire Grid Scan Average 0.0162
Maximum 0.07 Minimum 0.00
CU 0.00
No. of Points 55
LUMINAIRE INFORMATION
Applied Circuits B
No. of Luminaires 18 Total Load 13.26 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
41 20
47 57
B3 B4
A3 A4
A7
A8
B7
A9A10
EM
EM
W
VW
V
\pxqc;GATE
\pxqc;GATE20
C1
C2
A5
A6
B5
B6
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A3-A4 60' - 60' TLC-LED-550 2 2 0
60' TLC-LED-900 1 1 0
15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' TLC-LED-900 4 4 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 2 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED CANDELA (PER FIXTURE)
Entire Grid Scan Average 1803.6656
Maximum 10370.38 Minimum 4.57
CU 0.00
No. of Points 55
LUMINAIRE INFORMATION
Applied Circuits B
No. of Luminaires 18 Total Load 13.26 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B2
A2
B3 B4
A3 A4
A7
A8
B7
B8
A9A10
EM
\pxqc;GATE
\pxqc;GATE
\pxqc;CHAINLINK FENCE
C1
C2
A5
A6
B5
B6
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00 0.00
0.00 0.01 0.00 0.00 0.00
0.00 0.00
0.00 0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.01
0.00
0.00
0.01
0.01
0.00 0.00
0.00 0.000.000.000.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A5-A6 70' - 70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
2 B5-B6 70' - 70' TLC-LED-900 4 4 0
2 C1-C2 70' - 70' TLC-LED-550 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
6 Totals 26 26 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 3 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid Scan Average 0.0012
Maximum 0.01 Minimum 0.00
CU 0.00
No. of Points 63
LUMINAIRE INFORMATION
Applied Circuits C
No. of Luminaires 26 Total Load 20.98 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B2
A2
B3 B4
A3 A4
A7
A8
B7
B8
A9A10
EM
\pxqc;GATE
\pxqc;GATE
\pxqc;CHAINLINK FENCE
C1
C2
A5
A6
B5
B6
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00 0.00
0.01 0.02 0.00 0.01 0.01
0.01 0.00
0.00 0.00
0.01
0.01
0.00
0.00
0.00
0.00
0.00
0.01
0.01
0.02
0.04
0.00
0.01
0.01
0.01
0.01 0.00
0.00 0.010.000.000.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.01
0.00
0.00
0.00
0.01
0.00
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A5-A6 70' - 70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
2 B5-B6 70' - 70' TLC-LED-900 4 4 0
2 C1-C2 70' - 70' TLC-LED-550 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
6 Totals 26 26 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 3 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED MAX VERTICAL FOOTCANDLES
Entire Grid Scan Average 0.0043
Maximum 0.04 Minimum 0.00
CU 0.00
No. of Points 63
LUMINAIRE INFORMATION
Applied Circuits C
No. of Luminaires 26 Total Load 20.98 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B2
A2
B3 B4
A3 A4
A7
A8
B7
B8
A9A10
EM
\pxqc;GATE
\pxqc;GATE
\pxqc;CHAINLINK FENCE
C1
C2
A5
A6
B5
B6
291 1588 98
1035325
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A5-A6 70' - 70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
2 B5-B6 70' - 70' TLC-LED-900 4 4 0
2 C1-C2 70' - 70' TLC-LED-550 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
6 Totals 26 26 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 3 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED CANDELA (PER FIXTURE)
Entire Grid Scan Average 248.9704
Maximum 3407.48 Minimum 0.68
CU 0.00
No. of Points 63
LUMINAIRE INFORMATION
Applied Circuits C
No. of Luminaires 26 Total Load 20.98 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
B3 B4
A3 A4
A7
A8
B7
B8
0.00 0.00
0.00 0.00
0.00 0.00
0.00 0.00 0.00 0.00 0.00
0.00
0.00
0.00
0.00
0.01
0.02
0.04
0.03
0.02
0.02
0.02
0.01
0.01
0.01
0.01
0.02
0.02
0.04
0.03
0.02
0.00
0.00
0.00
0.00 0.00
0.000.000.00 0.00
0.00 0.00
0.00 0.00
0.00 0.00
0.00 0.00
0.00
0.00
0.01
0.00
0.00 0.00
0.00
A9A10
EM
W V
EM
W
VW
V
\pxqc;GATE
\pxqc;GATE
\pxqc;CHAINLINK FENCE
C1
C2
A5
A6
B5
B6
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A7-A8 60' - 60' TLC-LED-550 3 3 0
15.5' TLC-BT-575 1 1 0
2 B7-B8 70' - 70' TLC-LED-1200 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 4 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid Scan Average 0.0065
Maximum 0.04 Minimum 0.00
CU 0.00
No. of Points 55
LUMINAIRE INFORMATION
Applied Circuits D
No. of Luminaires 18 Total Load 13.16 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
B3 B4
A3 A4
A7
A8
B7
B8
0.00 0.00
0.00 0.00
0.01 0.00
0.00 0.00 0.00 0.00 0.00
0.00
0.00
0.00
0.00
0.03
0.06
0.11
0.09
0.08
0.07
0.06
0.05
0.02
0.03
0.05
0.06
0.07
0.11
0.07
0.04
0.01
0.00
0.00
0.00 0.00
0.000.000.00 0.00
0.00 0.00
0.01 0.01
0.00 0.00
0.00 0.00
0.00
0.01
0.02
0.01
0.01 0.00
0.00
A9A10
EM
W V
EM
W
VW
V
\pxqc;GATE
\pxqc;GATE
\pxqc;CHAINLINK FENCE
C1
C2
A5
A6
B5
B6
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A7-A8 60' - 60' TLC-LED-550 3 3 0
15.5' TLC-BT-575 1 1 0
2 B7-B8 70' - 70' TLC-LED-1200 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 4 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED MAX VERTICAL FOOTCANDLES
Entire Grid Scan Average 0.0197
Maximum 0.11 Minimum 0.00
CU 0.00
No. of Points 55
LUMINAIRE INFORMATION
Applied Circuits D
No. of Luminaires 18 Total Load 13.16 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
B2
A1
A2
B3 B4
A3 A4
A7
A8
B7
B8
0 0 0
A9A10
EM
W V
EM
W
VW
V
\pxqc;GATE
\pxqc;GATE
\pxqc;CHAINLINK FENCE
C1
C2
A5
A6
B5
B6
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A7-A8 60' - 60' TLC-LED-550 3 3 0
15.5' TLC-BT-575 1 1 0
2 B7-B8 70' - 70' TLC-LED-1200 1 1 0
70' TLC-LED-900 3 3 0
15.5' TLC-BT-575 1 1 0
4 Totals 18 18 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 4 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED CANDELA (PER FIXTURE)
Entire Grid Scan Average 804.0971
Maximum 3752.80 Minimum 0.00
CU 0.00
No. of Points 55
LUMINAIRE INFORMATION
Applied Circuits D
No. of Luminaires 18 Total Load 13.16 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
A1
A2
A3 A4
A7
A8
B7
B8
A9 A10
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 0 0.0
0 0.0 0 0.0
0 0.0 0 0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 00.0
00.0
0.0
0.0
0.0
0.0
EM
EM
\pxqc;CHAINLINK FENCE
A5
A6
B6
SCALE IN FEET 1 : 80
0' 80' 160'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A9-A10 50' - 50' TLC-LED-550 1 1 0
50' TLC-LED-900 3 3 0
2 Totals 8 8 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 5 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid Scan Average 0.0001
Maximum 0.00 Minimum 0.00
CU 0.00
No. of Points 47
LUMINAIRE INFORMATION
Applied Circuits E
No. of Luminaires 8 Total Load 6.36 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
A1
A2
A3 A4
A7
A8
B7
B8
A9 A10
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 0 0.0
0 0.0 0 0.0
0 0.0 0 0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 00.0
00.0
0.0
0.0
0.0
0.0
EM
EM
\pxqc;CHAINLINK FENCE
A5
A6
B6
SCALE IN FEET 1 : 80
0' 80' 160'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A9-A10 50' - 50' TLC-LED-550 1 1 0
50' TLC-LED-900 3 3 0
2 Totals 8 8 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 5 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED MAX VERTICAL FOOTCANDLES
Entire Grid Scan Average 0.0004
Maximum 0.00 Minimum 0.00
CU 0.00
No. of Points 47
LUMINAIRE INFORMATION
Applied Circuits E
No. of Luminaires 8 Total Load 6.36 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
B1
A1
A2
A3 A4
A7
A8
B7
B8
A9 A10
21 37 63 7 1
787897
EM
EM
\pxqc;CHAINLINK FENCE
A5
A6
B6
SCALE IN FEET 1 : 80
0' 80' 160'
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE GRADE
LEVEL LUMINAIRE TYPE QTY/POLE THIS
GRID
OTHER
GRIDS
2 A9-A10 50' - 50' TLC-LED-550 1 1 0
50' TLC-LED-900 3 3 0
2 Totals 8 8 0
*Above Grade level relative to the field
Ambucs Park Griffin, GA
Grid Summary Name Field 5 Spill
Spacing 30.0' x 30.0' Height 3.0' above grade
Illumination Summary
MAINTAINED CANDELA (PER FIXTURE)
Entire Grid Scan Average 12.9798
Maximum 96.52 Minimum 0.00
CU 0.00
No. of Points 47
LUMINAIRE INFORMATION
Applied Circuits E
No. of Luminaires 8 Total Load 6.36 kW
Pole location(s) dimensions are relative to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciation factor.
Field Measurements: Individual field measurements may vary from computer-calculated predictions and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures
EQUIPMENT LAYOUT
Ligh ng, LLC. ©1981, 2023 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: C.Lapaczonek • File #185321C_R1 • 23-Sep-24
Ambucs Park Griffin, GA
Field 1175'/180'/180' - basepath 60'
B1
B2
A1
A2
Fiel d 2
5'/
8'/
1'
- b as ep ath
B3
B4
A3
A4
A7
A8
B7
B8
Field 4
200'/200'/183' - basepath 60'
Field
5'/
5'/
5'
- b as ep ath
A9
A10
EM
W V
EM
W
VW
V
\pxqc;GATE
\pxqc;GATE
\pxqc;CHAINLINK FENCE
Field 3
258'/268'/275' - b asepath 90'
C1
C2
A5
A6
B5
B6
SCALE IN FEET 1 : 150
0' 150' 300' Pole location(s) dimensions are relative to 0,0 reference point(s)
Equipment Layout
INCLUDES:
· Field 1
· Field 2
· Field 3
· Field 4
· Field 5 Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.
Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.
Equipment List For Areas Shown Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
ABOVE
GRADE LEVEL LUMINAIRE TYPE QTY/POLE
4 A1-A4 60' - 60' TLC-LED-550 2
60' TLC-LED-900 1
15.5' TLC-BT-575 1
2 A5-A6 70' - 70' TLC-LED-900 3
15.5' TLC-BT-575 1
2 A7-A8 60' - 60' TLC-LED-550 3
15.5' TLC-BT-575 1
2 A9-A10 50' - 50' TLC-LED-550 1
50' TLC-LED-900 3
4 B1-B2
C1-C2 70' - 70' TLC-LED-550 1
70' TLC-LED-900 3
15.5' TLC-BT-575 1
2 B3-B4 70' - 70' TLC-LED-900 4
15.5' TLC-BT-575 1
2 B5-B6 70' - 70' TLC-LED-900 4
2 B7-B8 70' - 70' TLC-LED-1200 1
70' TLC-LED-900 3
15.5' TLC-BT-575 1
20 Totals 88
Single Luminaire Amperage Draw Chart Driver Speci ca ons
(.90 min power factor) Line Amperage Per Luminaire
(max draw)
Single Phase Voltage 208 (60)
(60)
(60)
(60)
(60)
(60)
(60)
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0
TLC-LED-550 3.2 3.0 2.8 2.4 1.9 1.8 1.4
TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3
File details come from the government source that posted it. Updated .