7-!-CR27015-23029310 DFCM Addendum 001.pdf
PDF 3 MB Posted
- Solicitation number
- CR27015
- Issued by
- Utah County, Utah
About this file
This is a Scope of Work and Addendum document issued by the Utah Division of Facilities Construction and Management (DFCM) for asbestos and hazardous materials abatement work at the Provo Regional Building located at 150 East Center Street, Provo, Utah 84606. The project encompasses removal and proper disposal of fireproofing containing 0.25% tremolite/actinolite asbestos from approximately 15,125 square feet of basement level ceiling and structural elements; removal of 247 PCB-containing ballasts; disposal of approximately 450 fluorescent light tubes; removal of 30 auto door closer units; and removal of approximately 50 square feet of lead-based paint on bathroom wall tile in the northwest section. The anticipated project start date is September 21, 2026, with a substantial completion date of November 20, 2026. Bidding is limited to prequalified hazmat contractors on the DFCM Prequalified Contractors list as of the solicitation date. The project includes a base bid and one bid alternate for removal of up to four 40-yard dumpsters of furniture. All bidders must acknowledge receipt of Addendum #001 dated September 10, 2026 with their bid submission or face potential disqualification.
Bidders must submit unit pricing along with their base bid for potential unforeseen asbestos-containing materials and other items using the provided Unit Price Sheet, which includes rates for additional mobilizations, supervisor and worker hourly rates, various hazardous materials removal costs, and demolition work. All contractors must possess current Utah Division of Air Quality certifications for workers and company-level certifications and must comply with EPA NESHAP regulations (40 CFR Part 61, Subpart M), OSHA Asbestos Standards (29 CFR 1910.1001 and 1926.1101), and Utah Asbestos Rule (Rule R-307.801). Contractors are required to provide an abatement project design prepared by an AHERA-accredited Utah Certified Project Designer no later than three working days before project start and must conduct daily personnel air sampling during friable removal activities with results submitted by end of shift the following workday. The contractor must hire a Utah-licensed electrical contractor, establish appropriate containment with negative air machines, provide decontamination facilities, and furnish weight and measure certifications for all asbestos waste before final payment is made. Water, electricity, and restroom facilities will be provided at no cost to the contractor by the owner.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DFCM Addendum Cover Page, 9.2.2026
DFCM Addendum #001
Reference: Provo Regional Center Building Wide Upgrades- Abatement DFCM Project #23029310 U3P Event #CR27015
Date: September 10, 2026
To: Prequalified Hazmat Contractors
From: The Division of Facilities Construction and Management
Note: This Addendum shall be included as part of the Contract Documents. Items in this Addendum apply to all drawings and specification sections whether referenced or not involving the portion of the work added, deleted, modified, or otherwise addressed in the Addendum. Bidders are required to acknowledge receipt of this Addendum when their bid is submitted. Failure to do so may subject the Bidder to disqualification.
Addendum Items
Solicitation Schedule Changes: There are no changes to the Solicitation Schedule in this addendum.
DFCM Addendum Items: N/A
Click to enter text Click to enter text Click to enter text
A/E Addendum Items: A/E Addendum # 001- Dated 09/10/2026 Click to enter text
Total Attached Pages: 65
ADDENDUM #1
ASBESTOS AND HAZARDOUS MATERIALS
SCOPE-OF-WORK:
FOR THE
UTAH DFCM PROVO REGIONAL BUILDING
BASEMENT ABATEMENT PROJECT
150 EAST CENTER STREET
PROVO, UTAH 84606
September 10, 2026
Prepared for:
Mrs. Aubrey Stapel Project Manager
State of Utah Department of Administrative Services
Division of Facilities Construction and Management (DFCM) State Office Building Room 4110
Salt Lake City, Utah 84114
PH: (801) 641-0964
Prepared by:
R & R Environmental, Inc. (R & R) (ASBC-#237)
47 West 9000 South, Suite #2 Sandy, Utah 84070 jamison@rrenviro.com Phone (801) 928-1560
Division 02 - Site Work
02 000 General
02 080 Hazardous Material Abatement
02 081 Asbestos Abatement:
Scope of Work: Provo Regional Basement Abatement Project Phase 1, 150 East Center Street, Provo, Utah 84720
Anticipated Start Date: September 21, 2026 Substantial Completion Date: November 20, 2026
Base Bid:
1. Fireproofing
a. Contractor shall remove all Fireproofing from the basement level of the Provo Regional Building. This material contains 0.25% tremolite/actinolite asbestos.
There is approximately 15,125 square feet to be removed. This material is not currently friable.
1 This work includes but not limited to the removal of the ceiling grid throughout the basement and demo/disposal of necessary drywall to abate the fireproofing on the columns throughout the basement. (See attached drawing)
2 Contractor may move any remaining furnishings left in the basement as needed to complete their work.
3 Contractor shall demo and dispose of all walls shown on the drawings to be removed.
2. Universal Waste
a. Contractor shall remove and properly dispose of all PCB-containing ballasts in the basement level of the building. 247 ballasts are suspected.
b. Contractor shall remove and properly dispose of all fluorescent light tubes in the basement level of the building. 450 bulbs have been identified.
c. Contractor shall remove and properly dispose of 30 auto door closer units in the basement level of the building.
3. General
a. All applicable rules will apply including Utah Division of Air Quality (DAQ) Utah Asbestos Rule (Rule R-307.801), EPA NESHAP (40 CFR Part 61, Subpart M), OSHA Asbestos Standard (29 CFR 1910.1001), and OSHA Asbestos Construction Standard (29 CFR 1926.1101)
b. Contractor shall have current and up-to-date Utah DAQ certifications for all workers conducting abatement. Contractor shall have current and up-to-date Utah DAQ Company Certification. Contractor shall submit a copy of Company Certification and all Individual Certifications as part of their Statement of Qualifications (SOQ).
c. Contractor shall attend a pre-start meeting on the first day of the project and shall ensure that the project supervisor is in attendance. The exact time for this meeting will be confirmed with the Contractor by the Consultant no later than one week prior.
d. Contractor shall conduct personnel air sampling each day of friable removal activity, and shall submit (in writing) all personal air sampling results from the workers on the project to the Consultant no later than the end of the shift the following workday.
e. Contractor shall ensure his work does not cause undue interference with the facility operation outside his abatement area, or unsightly accumulations of debris, materials, personal belongings, etc., and that all areas of the work are secure from the unauthorized entry of patrons and employees of the Owner.
f. Contractor shall provide Consultant with his abatement project design, prepared by an AHERA-accredited Utah Certified Project Designer, no later than 3 working days prior to the start of the project. Any modifications to the design shall be approved by an AHERA-accredited and Utah Certified Project Designer. The design shall be emailed or otherwise delivered to the offices of R&R Environmental, Inc., to the attention of Steve Smith, 47 West 9000 South, Suite 2, Sandy, Utah, 84070, steve@rrenviro.com.
g. Contractor shall hire a Utah-licensed electrical contractor to ensure his electrical design and plans are compatible with the facility operation and with the National Electrical Code. Contractor shall use only electrical equipment rated for work in "damp environments" in the containment area. Any equipment not labeled "rated for work in damp environments" may not be permitted.
h. Contractor shall ensure all equipment brought onto the site is free of suspect asbestos-containing material (ACM). Consultant may disallow use of any equipment with obvious suspect ACM.
i. All ladders and their components shall be maintained in good repair and fully operational, without makeshift repairs.
j. Contractor shall frame around and protect network computer and cables during abatement. Protect control panels on walls throughout abatement. Protect fire barriers around stairwells, elevator shaft, communication rooms, electrical rooms, restrooms, and etc.
k. Contractor shall take appropriate steps to safeguard existing items that are scheduled to remain in the facility. These items may include carpeting, flooring, baseboards, wood panels, ceiling trim, equipment such as burglar and fire alarms, sprinklers and sensors, speakers, clocks, mechanical grilles, furnaces, light fixtures, conduits, etc.
l. Contractor shall provide a certificate of weight and measure (or other certification acceptable to the Consultant) for all ACM waste taken from the site. The certification shall list gross, tare and net weights for all ACM waste. Contractor shall also provide, on Contractor's letterhead, a listing of each manifest used for the project, by number and waste tonnage (in pounds) specific to that manifest.
Listing shall show if ACM was disposed of as regulated waste, non-hazardous or any other state-approved category of waste. This information shall be provided prior to, or at the time of invoice submission. No final payment to Contractor will be made without this certification and documentation.
m. All poly sheeting used by Contractor on the project shall be of the fire-retardant type. Each containment area shall be built with a clear plexiglass window no smaller than two feet square, which allows viewing of the entire work from outside the regulated area.
n. Smoking / vaping is not allowed in the building. Contractor's employees who smoke shall go off-site or to a corner of the property and shall police and clean up any cigarette butts or associated debris, transporting this waste immediately to their privately-owned vehicle or a company vehicle. Owner's trash receptacles shall not be used for this waste. Any violation of this provision is grounds for expulsion of the offending party from the work site for its duration.
o. The most stringent regulations in effect for the work site shall apply. Contractor shall determine the extent of city, county, AQMD, state, federal and all other applicable regulations and perform the work in compliance with these regulations.
p. Reserved.
q. Contractor shall provide the Industrial Hygiene Consultant with SDSs for all materials used on their work site. SDSs shall be provided prior to the use of the product.
r. Contractor shall provide an English-speaking interpreter on-site any time
Contractor personnel are non-English-speaking.
s. Contractor’s electrical extension cords shall be suspended off the floor or covered with trip-resistant covering. GFCIs shall be used on all electrical equipment.
t. Removed ACM shall be cleaned up and bagged on a continual basis. No removed
ACM shall be left unattended at any time until placed in the locked waste dumpster. All waste shall be disposed of at an in-state waste facility unless agreed to in writing by the Consultant prior to transport. Contractor shall use a waste container that can be made secure from unauthorized disposal, so no extraneous waste is included with the ACM waste generated by Contractor. All ACM waste shall be transported in leak-tight containers, in poly-lined, enclosed, locked vehicles, separate from non-ACM material.
u. Contractor shall maintain a job telephone at Contractor's expense. Telephone shall be operational prior to disturbance of any ACM. Contractor shall be fully responsible for all charges to this telephone.
v. Contractor is allowed to use the bathrooms on the basement level. Contractor shall ensure these toilets are maintained appropriately and in a hygienic manner and are established and maintained throughout the duration of the project while contractor is on site.
w. All dimensions, quantities and areas provided in this scope of work are approximations to assist Contractor in determining the amount of ACM designated for removal. Contractor is entirely responsible for accurately determining the amount of ACM included in the scope of work prior to submitting bid forms and proposal.
4. Lead Based Paint Work
a. Bathroom Wall Tile (Purple) -Contractor shall remove and properly dispose of the Bathroom Wall Tile (Purple) in the NW section. This material contains lead-based paint. There is approximately 50 square feet of material to be removed.
This material shall be disposed of as construction debris (See the attached TCLP results)
5. Lead Work - Scope of Work, Specific:
a. A. Disposal of Containment Debris, Protective Suits, Respirator Cartridges, Cleaning Materials, Waste Water, Etc.
1. Consultant will conduct TCLP (toxic characteristic leaching procedure) sampling to determine waste disposal requirements.
b. Requirements for Containment, Negative Air, Personal Hygiene and PPE
1. Contractor shall establish appropriate critical barriers in all areas where lead cleanup is taking place and use negative air machines to maintain a negative pressure within these areas until cleaning is completed.
2. Contractor shall provide a decontamination chamber with washing facilities, which meet the requirements of OSHA 1926.62.
3. Contractor shall provide appropriate personal protective equipment according to OSHA guidelines to protect workers from lead hazards.
c. HEPA-vacuuming and Wet-cleaning Requirements
1. Where HEPA-vacuuming is specified, abatement contractor shall use HEPA vacuums to remove surface dust so that no visible dust remains on these surfaces.
2. Where wet-cleaning is specified, abatement contractor shall first moisten surfaces to be cleaned, apply Spic and Span Cleansing Powder to surface and allow it to absorb the moisture, and then wipe the surface using paper towels. Note: A supplier for Spic and Span is: Spic and Span Company, 94 North Broadway, Irvington, NY 10533.
d. Personal Air Sampling and Area Air Sampling
1. All personal air sampling and any area air sampling shall be conducted by the contractor.
e. Water, Electricity, and Restroom Facilities
1. Water and electricity will be provided by the Owner at no cost to the Contractor.
2. Restroom facilities will be provided by the Owner at no cost to the
Contractor. Contractor shall ensure restroom facilities are kept clean and in good working order. If, in the opinion of the Owner or the Owner’s representative, the restroom facilities are deemed dirty or not in good working order the Contractor will not be allowed further use of the restroom facilities.
f. Worker Training and Physical Exam Qualifications
1. All of the Contractor's supervisors and workers assigned to this project will have evidence of successfully completing at least the 16-hour EPA Lead-based Paint worker course or the OSHA 1926.62 (1) mandated training.
2. All of the Contractor's supervisors and workers assigned to this project will have blood sampling and analysis for lead and zinc protoporphyrin levels both immediately before and immediately after working on this project in addition to meeting other Medical Surveillance requirements outlined in OSHA 1926.62 6). Analysis results will be provided to the Consultant as part of project documentation.
g. Protection / Contractor Caused Damage to the Building and Grounds
1. Contractor shall be responsible for protecting the portion of the building and grounds where contractor’s personnel are working or transiting through. Contractor shall be responsible for repairing any Contractor-damaged areas to the Owner’s satisfaction.
2. Contractor shall take particular care to ensure that dumpsters and the trucks delivering and removing dumpsters do not damage building or grounds.
BID ALTERNATE #1:
1. Contractor shall remove all furniture from the lower level of the building. Contractor is to assume up to four (4) 40-yard dumpsters of furniture that needs to be removed and disposed of.
APPENDIX A
UNIT PRICE SHET
UTAH DFCM PROVO REGIONAL BUILDING
BASEMENT LEVEL ABATEMENT PROJECT
September 10, 2026 Company Name:
Unit Pricing: Bidding abatement contractors are to submit their base bid along with the following unit costs for any unforeseen asbestos-containing building materials using the Unit Pricing Cost Sheet which is posted separately.
Item No.
Description
Unit
Unit Price
1 Additional Mobilizations Each $ 2 Hourly Supervisor Rate Hr $ 3 Hourly Worker Rate Hr $ 4 Fluorescent light ballast Each $ 5 Fluorescent light tubes 2’ to 8’ long Each $ 6 PCB Ballast Each $ 7 Batteries Each $ 8 Auto Door Closer Units Each $ 9 Thermometers Each $ 10 Chemicals gal $ 11 Paints gal $ 12 Glycol gal $ 13 Fire Extinguisher Each $ 14 Gas Cylinder Each $ 15 Radioactive Emergency Exit Signs Each $ 16 Refrigerant unit CFC evacuation Each $ 17 Refrigerant unit CFC evacuation (<50 lbs) Each $ 18 Refrigerant unit CFC evacuation (>50 to 300 lbs) Each $ 19 Refrigerant unit CFC evacuation (>300 lbs) Each $ 20 E-waste (Small) Each $ 21 E-waste (Med) Each $ 22 E-waste (Large) Each $ 23 TV/Monitor/Laptop Each $ 24 Oil gal $ 25 60 gal containers of lead containing items gal $ 26 Fireproofing (Ceiling) SF $ 27 Fireproofing (Beam) SF $ 28 Drywall Demo SF $ 29 Raised Floor Demo SF $ 30 Ducting Demo SF $ 31 Insulation Demo SF $ 32 Piping Demo LF $ 33 Ceiling Panel Grid Removal SF $ 34 Ceiling Panel Grid Demo SF $ 35 Ceiling Demo SF $ 36 40-yard dumpster Each $
APPENDIX B
SITE PLANS
APPENDIX C
ASBESTOS SURVEY AND ASSESSMENT REPORTS
ASBESTOS (LIMITED), LEAD (LIMITED), AND HAZARDOUS MATERIALS
INSPECTION, SURVEY AND ASSESSMENT
FOR THE LOWER LEVEL OF THE
PROVO REGIONAL BUILDING
A LIMITED ASBESTOS SURVEY AND ASSESSMENT
FOR THE LOWER LEVEL OF THE
PROVO REGIONAL BUILDING
August 15, 2026
HazMat Project Manager
Division of Facilities Construction and Management (DFCM)
Department of Government Operations
AStapel@utah.gov
R & R Environmental, Inc. (R & R)
47 West 9000 South, Suite #2
Sandy, Utah 84070 steve@rrenviro.com
Phone (801) 318-5658
TABLE OF CONTENTS
ASBESTOS
1.0 INTRODUCTION
2.0 EXECUTIVE SUMMARY
3.0 SAMPLING METHODS
4.0 SURVEY RESULTS
5.0 CONCLUSIONS
6.0 LIMITATIONS AND EXCLUSION OF WARRANTY
List of Appendices
Appendix A Sample Log
Appendix B Laboratory Report
Appendix C Photo Log
Appendix D State of Utah Certifications
Limited Asbestos Survey Report Page 1 Provo Regional Building
1.0 INTRODUCTION
R & R Environmental, Inc. (R & R) was contacted to conduct a limited asbestos survey for the
Provo Regional Building located at 150 East Center Street in Provo, Utah 84606. The Lower
Level (except the restrooms) is set to undergo a renovation. The survey consisted of a visual assessment of all the Lower Level (except for the restrooms) for suspect asbestos containing materials (ACM) and bulk sampling of the materials. The fieldwork component of this survey was conducted by Mr. Steve Smith who is a Utah Accredited Asbestos Building Inspector.
This report presents the conditions and observations noted on the visit dates.
The following general information is included in this survey report:
• Executive Summary (Section 2.0)
• Sampling Methods (Section 3.0)
• Analytical Results (Section 4.0)
• Conclusions (5.0)
• Limitations and Exclusions of Warranty (6.0)
Limited Asbestos Survey Report Page 2
2.0 EXECUTIVE SUMMARY
The asbestos-containing material (ACM) identified at the Lower Level of the Provo Regional
Building located at 150 East Center Street in Provo, Utah 84606 is as follows:
Material Location Quantity % Asbestos Friable Condition
Photo
Fireproofing Above Ceilings
Throughout ~15, 125 ft2
0.25%
Tremolite/Actinolite
(By Point Count)
No Good 2
Limited Asbestos Survey Report Page 3
PROVO REGIONAL BUILDING
DATE OF SURVEY: AUGUST 2026
NESHAP - REGULATED
ASBESTOS-CONTAINING MATERIALS (R-ACM)
1. Friable asbestos material (>1% asbestos and can be crumbled, pulverized, or reduced to powder by hand pressure)
Thermal system insulation (TSI)*
Textured ceiling material (TCM)*
Spray-on insulation or fireproofing*
Blown-in insulation*
Ceiling tiles/panels*
Plaster, gypsum board, gypsum board joint compound*
Cloth materials* (Boiler Flue Gasket)
Paper materials* (HVAC Paper Tape and Insulating Board)
Electrical wiring insulation*
Sink undercoating (loose)*
Other*
2. Category I ACM which has become friable
Packings
Gaskets
Resilient floor coverings (floor tile and sheet vinyl)
Asphalt roofing products (Dust Debris, Roofing Underlayment Debris, Flashing Material)
3. Category I ACM that will be or has been subjected to sanding, grinding, cutting, or abrading
Packings
Gaskets
Resilient floor coverings (floor tile and sheet vinyl)
Asphalt roofing products
4. Category II ACM that has a high probability of becoming or has become friable during demolition or renovation operations
Asbestos cement materials (TransiteT)*
Asphalt, tar and rubber-base ACM products other than roofing products*
Non-asphalt and non-paper roofing products*
Paint*
Fire brick and/or mortar*
Stainless steel sink undercoating (solid)*
Encapsulated TCM*
Encapsulated TSI*
Mastic for floor tile, ceiling tile, cove molding, etc.*
Other
Limited Asbestos Survey Report Page 4
PROVO REGIONAL BUILDING
DATE OF SURVEY: AUGUST 2026
NESHAP NON-REGULATED
ASBESTOS-CONTAINING MATERIAL (N-R-ACM)
1. > 1% asbestos
2. Category I Non-friable (cannot be crumbled, pulverized, or reduced to powder by hand pressure)
ACM with >1% asbestos by new PLM procedure
Packings
Gaskets
Resilient floor coverings
Asphalt roofing products
3. Category II Non-friable ACM with >1% asbestos by new PLM procedure (Category includes items meeting Category I definition but not specifically listed in that category)
Asbestos cement materials (TransiteT)* (Fume hoods, counter tops, and window panels)
Asphalt, tar and rubber-base ACM products other than roofing products*
Non-asphalt and non-paper roofing products*
Paint* (Silver Paint Sealant)
Fire brick and/or mortar*
Sink undercoating (solid)*
Mastic for floor tile, ceiling tile, cove molding, etc.*
Other* (Safes, Fire Rated Door)
Notes:
1. (*) Denotes R&R’s interpretation of materials included in this category.
2. New PLM procedure is outlined in Appendix A, Subpart F, 40 CFR, Part 783, Section 1, Polarized Light Microscopy.
3. The Environmental Protection Agency (EPA) National Emission Standard for Hazardous Air
Pollutants (NESHAP) asbestos revision as outlined in 40 CFR, Part 61, became effective
November 20, 1990. The asbestos classification system outlined in the revision and included in this section is dynamic in nature. Asbestos materials classified as “NON-REGULATED” at the time of the survey may become “REGULATED” due to ongoing or planned maintenance, renovation, or demolition actions, which can transform a material containing greater than 1% asbestos from a “non-friable” and NON-REGULATED to a friable and REGULATED condition.
Classification of ACM in this section and in the executive summary of this report is, therefore, based on the observations of the surveyor at the time of the survey and may or may not be appropriate at later dates.
4. Maintenance, renovation, demolition, weathering, normal wear, water, or other damage can alter the “NON-REGULATED” status of materials, and necessitate precautions required for handling them as “REGULATED” asbestos-materials.
Limited Asbestos Survey Report Page 5
3.0 SAMPLING METHODS
Survey procedures were based on those outlined in Title 40 Code of Federal Regulation (CFR)
Part 763, USEPA Asbestos Hazard Emergency Response Act, and the Asbestos Model
Accreditation Plan (effective April 4, 1994). The procedures included visual observation, physical inspection, bulk sample collection, and condition assessment of suspect ACM. The number of samples collected was based on the amount and accessibility of each homogeneous material, with consideration given for the type, age, and condition.
Thirty – seven (37) samples were collected from the suspect materials to assess the presence of asbestos (or lack thereof) in building materials/systems. Each sample collected was placed into a sealable plastic bag or tub, marked with a unique sample identification code, and packaged for subsequent shipment to the laboratory for analysis. Individual sample identification consisted of a numeric code denoting the sampling media/location.
After packaging and labeling, samples were submitted under proper chain-of-custody to Eurofins
Reservoirs Environmental, Inc., Denver, Colorado. The National Voluntary Laboratory
Accreditation Program (NVLAP), Lab Code 101896 accredits Eurofins Reservoirs for asbestos analysis. Samples were analyzed via Polarized Light Microscopy (PLM) utilizing EPA Method
600/M4-82-020. Please note that USEPA and OSHA regulations define an ACM as a material containing more than one (1) percent asbestos, by volume, as determined by PLM analysis. In the case of multi-layer systems (e.g., floor tile/mastic layers), the laboratory analyzed and reported each layer separately.
4.0 SURVEY RESULTS
Thirty – seven (37) representative samples collected were submitted for analytical determination.
A summary of analytical results for samples collected and analyzed for this survey are in Appendix
B (Laboratory Results) and are discussed below by building material/system type. Photographs of the buildings where samples were taken are included as Appendix C. Floor Plans of the building where samples were taken are included in Appendix D
Limited Asbestos Survey Report Page 6
5.0 CONCLUSIONS
Asbestos-containing materials were identified in the building. See Executive Summary for positive materials details.
6.0 LIMITATIONS AND EXCLUSION OF WARRANTY
This asbestos survey and assessment was performed using procedures and a level of diligence typically exercised by professional consultants performing similar services. However, asbestos-containing material (ACM) can be present in a structure, but not identified using ordinary investigative procedures.
No asbestos survey can completely, eliminate uncertainty regarding the presence of ACM.
R&R Environmental, Inc.’s level of diligence and investigative procedures are intended to reduce, but not eliminate, potential uncertainty regarding the presence of ACM. The procedures used for this survey attempt to establish a balance between the competing goals of limiting investigative costs, time, and building damage, and reducing the uncertainty about unknown conditions. Therefore, the determinations in this report should not be construed as a guarantee that all ACM present in the subject property has been included in this report.
This report presents R&R Environmental, Inc.’s professional determinations, which are dependent upon information obtained during performance of consulting services. R&R
Environmental, Inc. assumes no responsibility for omissions or errors resulting from inaccurate information provided by sources outside of R&R Environmental, Inc.
No warranty or guarantee, expressed or implied, is made regarding the findings, conclusions, or recommendations contained in this report. The limitations presented above supersede the requirements or provisions of all other contracts or scopes of work, implied, or otherwise, except stated or acknowledged herein.
Limited Asbestos Survey Report Page 7
A LIMITED ASBESTOS SURVEY AND ASSESSMENT
OF THE
UTAH STATE GOVERNMENT
PROVO REGIONAL BUILDING
During the days of August 4-6, 2026, R & R Environmental, Inc. (R & R) of Sandy, Utah, conducted a limited asbestos survey and assessment of the Provo Regional Building located at 150
East Center Street in Provo, Utah 84606. Bulk samples of suspect asbestos-containing materials were collected and analyzed. The condition of all friable and non-friable asbestos-containing materials was, assessed. The following accredited inspector conducted the survey and assessment.
Inspected by:
Steve Smith Date
State of Utah, Division of Air Quality Inspector
Certification Number: ASB-3274
State of Utah Company Certification: ASBC-237
This report was reviewed by:
David C. Roskelley, MSPH, CIH, CSP Date
State of Utah, Division of Air Quality Inspector
Certification Number: ASB-1370
AHERA Inspector #5 PSI 65451 I
Certified Safety Professional #15774
Certified Industrial Hygienist #8529
State of Utah Company Certification: ASBC-237
Appendix A
Sample Log
SAMPLE LOG
Sample #
Material/
Homogenous Area
Sample Location
Quantity
Lab Result
(%/Type)
Assessment
PRC-8-5-01 Fire Door Insulation North Stairwell 34 each None Detected Undamaged
PRC-8-5-02 Fire Door Insulation Corridor 34 each None Detected Undamaged
PRC-8-5-03 2’ x 2’ Ceiling Panel L100 ~13,000 ft2 None Detected Undamaged
PRC-8-5-04 2’ x 2’ Ceiling Panel L100 ~13,000 ft2 None Detected Undamaged
PRC-8-5-05 Spray-on Fireproofing L120 ~15, 125 ft None Detected Undamaged
PRC-8-5-06 Spray-on Fireproofing L129 ~15, 125 ft None Detected Undamaged
PRC-8-5-07 Spray-on Fireproofing Office West ~15, 125 ft None Detected Undamaged
PRC-8-5-08
Spray-on Fireproofing L070 ~15, 125 ft
0.25%
Tremolite /
Actinolite
Undamaged
PRC-8-5-09 Spray-on Fireproofing L202 ~15, 125 ft None Detected Undamaged
PRC-8-5-10 Spray-on Fireproofing Corridor ~15, 125 ft None Detected Undamaged
PRC-8-5-11 Spray-on Fireproofing Elevator Lobby ~15, 125 ft None Detected Undamaged
PRC-8-5-12 Wall System Room 4100 2,022 ft2 None Detected Undamaged
PRC-8-5-13 Wall System Room 4100 1,381 ft2 None Detected Undamaged
PRC-8-5-14 Wall System Room 4200 1,381 ft2 None Detected Undamaged
PRC-8-5-15 Wall System Floor 4 Men’s 14 ft2 None Detected Undamaged
PRC-8-5-16 Wall System Floor 4 Women’s 14 ft2 None Detected Undamaged
PRC-8-5-17 Wall System Room 4200 23,881 ft2 None Detected Undamaged
PRC-8-5-18 Wall System Floor 4139 23,881 ft2 None Detected Undamaged
PRC-8-5-19 12” Vinyl Floor Tile & Mastic L132 4,350 ft2 None Detected Undamaged
PRC-8-5-20 12” Vinyl Floor Tile & Mastic L132 4,350 ft2 None Detected Undamaged
PRC-8-5-21 Sink Undercoating NW Breakroom 2 each None Detected Undamaged
PRC-8-5-22 Sink Undercoating DFCM Offices 2 each None Detected Undamaged
PRC-8-5-23 Vinyl Cove Base & Mastic
(Light Brown) Break Room 210 ft2 None Detected Undamaged
Sample #
Material/
Homogenous Area
Sample Location
Quantity
Lab Result
(%/Type)
Assessment
PRC-8-5-24 Vinyl Cove Base & Mastic
(Light Brown) Break Room 210 ft2 None Detected Undamaged
PRC-8-5-25 Vinyl Cove Base & Mastic
(Dark Brown) L134 1,088 ft2 None Detected Undamaged
PRC-8-5-26 Vinyl Cove Base & Mastic
(Dark Brown) L134 1,088 ft2 None Detected Undamaged
PRC-8-5-27 Vinyl Cove Base & Mastic
(Light Tan) Shop 103 ft2 None Detected Undamaged
PRC-8-5-28 Vinyl Cove Base & Mastic
(Light Tan) Shop 103 ft2 None Detected Undamaged
PRC-8-5-29 Vinyl Cove Base & Mastic
(Dark Gray) Electrical Vault ~95 ft2 None Detected Undamaged
PRC-8-5-30 Vinyl Cove Base & Mastic
(Dark Gray) Electrical Vault ~95 ft2 None Detected Undamaged
PRC-8-5-31 CMU Block Filler Paint SW Custodial ~1,600 ft2 None Detected Undamaged
PRC-8-5-32 CMU Block Filler Paint SW Custodial ~1,600 ft2 None Detected Undamaged
PRC-8-5-33 CMU Block Filler Paint Storage Cage ~1,600 ft2 None Detected Undamaged
PRC-8-5-34 Wall Paper / Glue L170 ~15,000 ft2 None Detected Undamaged
PRC-8-5-35 Wall Paper / Glue L170 ~15,000 ft2 None Detected Undamaged
PRC-8-5-36 Gray Floor Coating Storage Cage 809 ft2 None Detected Undamaged
PRC-8-5-37 Gray Floor Coating Storage Cage 809 ft2 None Detected Undamaged
Appendix B
Laboratory Report
August 07, 2026
Sincerely, Jeanne Spencer President
Subcontractor Number:
Laboratory Report: RES 774990-2
Project #/P.O. #: DFCM
Project Description: Provo Regional Center
Steve Smith R & R Environmental 47 West 9000 South #2 Sandy, UT 84070
Dear Steve, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
RES 774990-2 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer (i.e. sample volumes and areas). This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
by Camryn Baumgartner
08/07/202608/07/202608/07/202608/07/2026
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
4955 Yarrow St, Suite 100, Arvada, CO 80002
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non- AAAA SubSubSubSub AsbestosAsbestosAsbestosAsbestos FibrousFibrousFibrousFibrous YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 774990 -774990 -774990 -774990 - PRC-8-5-01PRC-8-5-01PRC-8-5-01PRC-8-5-01 A Off-white coating 30 NDNDNDND 5 95.0 B Tan wood debris 70 NDNDNDND 99 1.0 774990 -774990 -774990 -774990 - PRC-8-5-02PRC-8-5-02PRC-8-5-02PRC-8-5-02 A Tan wood debris 100 NDNDNDND 99 1.0 774990 -774990 -774990 -774990 - PRC-8-5-03PRC-8-5-03PRC-8-5-03PRC-8-5-03 A Light-gray/multi-colored ceiling tile 100 NDNDNDND 50 50.0 774990 -774990 -774990 -774990 - PRC-8-5-04PRC-8-5-04PRC-8-5-04PRC-8-5-04 A Light-gray/multi-colored ceiling tile 100 NDNDNDND 50 50.0 774990 -774990 -774990 -774990 - PRC-8-5-05PRC-8-5-05PRC-8-5-05PRC-8-5-05 A Tan fireproofing 100 NDNDNDND 25 75.0 774990 -774990 -774990 -774990 - PRC-8-5-06PRC-8-5-06PRC-8-5-06PRC-8-5-06 A Tan fireproofing 100 NDNDNDND 25 75.0 774990 -774990 -774990 -774990 - PRC-8-5-07PRC-8-5-07PRC-8-5-07PRC-8-5-07 A Tan fireproofing 100 NDNDNDND 25 75.0 774990 -774990 -774990 -774990 - PRC-8-5-08PRC-8-5-08PRC-8-5-08PRC-8-5-08 A Tan fireproofing 100 Trem/ActTrem/ActTrem/ActTrem/Act TRTRTRTR 25 75.0 Point Count Point Count Point Count Point Count <0.25<0.25<0.25<0.25 774990 -774990 -774990 -774990 - PRC-8-5-09PRC-8-5-09PRC-8-5-09PRC-8-5-09 A Tan fireproofing 100 NDNDNDND 25 75.0 774990 -774990 -774990 -774990 - PRC-8-5-10PRC-8-5-10PRC-8-5-10PRC-8-5-10 A Tan fireproofing 100 NDNDNDND 25 75.0 774990 -774990 -774990 -774990 - PRC-8-5-11PRC-8-5-11PRC-8-5-11PRC-8-5-11 A Tan fireproofing 100 NDNDNDND 25 75.0 774990 -774990 -774990 -774990 - PRC-8-5-12PRC-8-5-12PRC-8-5-12PRC-8-5-12 A White multi-layered tape 13 NDNDNDND 95 5.0 B White multi-layered joint compound 17 NDNDNDND 0 100.0 C White/tan drywall 70 NDNDNDND 10 90.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
774990-2 R & R Environmental
DFCM
Provo Regional Center August 06, 2026 EPA 600/R-93/116 - Point Count, Bulk (400) Priority August 06, 2026 - August 07, 2026
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 774990 -774990 -774990 -774990 - PRC-8-5-13PRC-8-5-13PRC-8-5-13PRC-8-5-13 A White tape 8 NDNDNDND 95 5.0 B White joint compound 16 NDNDNDND 0 100.0 C White/tan drywall 76 NDNDNDND 10 90.0 774990 -774990 -774990 -774990 - PRC-8-5-14PRC-8-5-14PRC-8-5-14PRC-8-5-14 A White multi-layered joint compound 10 NDNDNDND 0 100.0 B White compound w/ white paint 10 NDNDNDND 0 100.0 C White multi-layered tape 12 NDNDNDND 95 5.0 D White/tan drywall 68 NDNDNDND 10 90.0 774990 -774990 -774990 -774990 - PRC-8-5-15PRC-8-5-15PRC-8-5-15PRC-8-5-15 A White tape 8 NDNDNDND 95 5.0 B White compound w/ white paint 13 NDNDNDND 0 100.0 C White joint compound 14 NDNDNDND 0 100.0 D White/tan drywall 65 NDNDNDND 15 85.0 774990 -774990 -774990 -774990 - PRC-8-5-16PRC-8-5-16PRC-8-5-16PRC-8-5-16 A White compound 10 NDNDNDND 0 100.0 B White/tan drywall 90 NDNDNDND 10 90.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
774990-2 R & R Environmental
DFCM
Provo Regional Center August 06, 2026 EPA 600/R-93/116 - Point Count, Bulk (400) Priority August 06, 2026 - August 07, 2026
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%)
774990 -774990 -774990 -774990 - PRC-8-5-17PRC-8-5-17PRC-8-5-17PRC-8-5-17 A White tape 7 NDNDNDND 95 5.0 B White compound w/ white paint 9 NDNDNDND 0 100.0 C White joint compound 14 NDNDNDND 0 100.0 D White/tan drywall 70 NDNDNDND 10 90.0 774990 -774990 -774990 -774990 - PRC-8-5-18PRC-8-5-18PRC-8-5-18PRC-8-5-18 A White tape 7 NDNDNDND 95 5.0 B Blue compound w/ gray paint 7 NDNDNDND 0 100.0 C White joint compound 8 NDNDNDND 0 100.0 D White compound w/ white paint 8 NDNDNDND 0 100.0 E White/tan drywall 70 NDNDNDND 10 90.0 774990 -774990 -774990 -774990 - PRC-8-5-19PRC-8-5-19PRC-8-5-19PRC-8-5-19 A Gray granular cementitious material TR NDNDNDND 0 100.0 B Yellow adhesive 4 NDNDNDND 0 100.0 C Light-gray tile 96 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-20PRC-8-5-20PRC-8-5-20PRC-8-5-20 A Gray granular cementitious material 1 NDNDNDND 0 100.0 B Yellow adhesive 4 NDNDNDND 0 100.0 C Light-gray tile 95 NDNDNDND 0 100.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
774990-2 R & R Environmental
DFCM
Provo Regional Center August 06, 2026 EPA 600/R-93/116 - Point Count, Bulk (400) Priority August 06, 2026 - August 07, 2026
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 774990 -774990 -774990 -774990 - PRC-8-5-21PRC-8-5-21PRC-8-5-21PRC-8-5-21 A Off-white sink undercoating 100 NDNDNDND 15 85.0 774990 -774990 -774990 -774990 - PRC-8-5-22PRC-8-5-22PRC-8-5-22PRC-8-5-22 A Off-white sink undercoating 100 NDNDNDND 15 85.0 774990 -774990 -774990 -774990 - PRC-8-5-23PRC-8-5-23PRC-8-5-23PRC-8-5-23 A Cream adhesive 5 NDNDNDND 0 100.0 B Gray cove base 95 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-24PRC-8-5-24PRC-8-5-24PRC-8-5-24 A Cream adhesive 5 NDNDNDND 0 100.0 B Gray cove base 95 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-25PRC-8-5-25PRC-8-5-25PRC-8-5-25 A Cream adhesive 3 NDNDNDND 0 100.0 B Black cove base 97 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-26PRC-8-5-26PRC-8-5-26PRC-8-5-26 A Black cove base 100 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-27PRC-8-5-27PRC-8-5-27PRC-8-5-27 A Cream adhesive 6 NDNDNDND 0 100.0 B Tan/gray cove base 94 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-28PRC-8-5-28PRC-8-5-28PRC-8-5-28 A Cream adhesive TR NDNDNDND 0 100.0 B Tan/gray cove base 100 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-29PRC-8-5-29PRC-8-5-29PRC-8-5-29 A Gray cove base 100 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-30PRC-8-5-30PRC-8-5-30PRC-8-5-30 A Gray cove base 100 NDNDNDND 0 100.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
774990-2 R & R Environmental
DFCM
Provo Regional Center August 06, 2026 EPA 600/R-93/116 - Point Count, Bulk (400) Priority August 06, 2026 - August 07, 2026
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%)
774990 -774990 -774990 -774990 - PRC-8-5-31PRC-8-5-31PRC-8-5-31PRC-8-5-31 A White block filler paint 25 NDNDNDND 0 100.0 B Gray granular cementitious material 75 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-32PRC-8-5-32PRC-8-5-32PRC-8-5-32 A White block filler paint 30 NDNDNDND 0 100.0 B Gray granular cementitious material 70 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-33PRC-8-5-33PRC-8-5-33PRC-8-5-33 A Gray granular cementitious material 40 NDNDNDND 0 100.0 B White block filler paint 60 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-34PRC-8-5-34PRC-8-5-34PRC-8-5-34 A Tan adhesive 40 NDNDNDND 0 100.0 B Gray wall covering 60 NDNDNDND 25 75.0 774990 -774990 -774990 -774990 - PRC-8-5-35PRC-8-5-35PRC-8-5-35PRC-8-5-35 A Gray wall covering 100 NDNDNDND 25 75.0 774990 -774990 -774990 -774990 - PRC-8-5-36PRC-8-5-36PRC-8-5-36PRC-8-5-36 A Gray paint 5 NDNDNDND 0 100.0 B Gray granular cementitious material 95 NDNDNDND 0 100.0 774990 -774990 -774990 -774990 - PRC-8-5-37PRC-8-5-37PRC-8-5-37PRC-8-5-37 A Gray paint 5 NDNDNDND 0 100.0 B Gray fibrous micaceous material 20 NDNDNDND 15 85.0 C Gray granular cementitious material 75 NDNDNDND 0 100.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Anya Angst Analyst
Que Pham Analyst
Nicholas Coscarella Analyst
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
774990-2 R & R Environmental
DFCM
Provo Regional Center August 06, 2026 EPA 600/R-93/116 - Point Count, Bulk (400) Priority August 06, 2026 - August 07, 2026
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
SUBMITTED BY INVOICE TO
Client Sample ID Number
RES Job #: 774990
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Company: R & R Environmental Company: R & R Environmental
Address: 47 West 9000 South #2 Address: 47 West 9000 South #2
Sandy, UT 84070 Sandy, UT 84070
Project Number and/or P.O. #: DFCM Project Zip Code:
Project Description/Location: Provo Regional Center
Contact: Steve Smith -1 PLM Priority Phone: (801) 318-5658
Fax:
Cell: (801) 318-5658
Final Data Deliverable Email Address:
steve@rrenviro.com (+ 23 ADDNL. CONTACTS)
PLM / PCM / TEM / NYS DTL RUSH PRIORITY STANDARD Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
Mold Analysis RUSH PRIORITY STANDARD
Special Instructions:
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
1 PRC-8-5-01 X B
2 PRC-8-5-02 X B
3 PRC-8-5-03 X B
4 PRC-8-5-04 X B
5 PRC-8-5-05 X B
6 PRC-8-5-06 X B
7 PRC-8-5-07 X B
8 PRC-8-5-08 X B
9 PRC-8-5-09 X B
10 PRC-8-5-10 X B
11 PRC-8-5-11 X B
12 PRC-8-5-12 X B
13 PRC-8-5-13 X B
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
N Y
S
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET30. Failure to comply with payment terms may result in a 18% APR finance charge.
Relinquished By:
Steve Smith Date/Time: 08/05/2026 14:23:32 Sample Condition: Acceptable
Received By:
Aubree Klausner Date/Time: 08/06/2026 11:24:27 Carrier: Fed-Ex
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Client Sample ID Number
REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
Laboratory Analysis Instructions
(Sample ID's must be unique)
Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Surface = SU Swab = SW
Tape = T Wipe = W
Drinking Water = DW
Waste Water = WW
**ASTM E1792 approved wipe media only**
RES Job #: 774990
Submitted By: R & R Environmental
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
14 PRC-8-5-14 X B
15 PRC-8-5-15 X B
16 PRC-8-5-16 X B
17 PRC-8-5-17 X B
18 PRC-8-5-18 X B
19 PRC-8-5-19 X B
20 PRC-8-5-20 X B
21 PRC-8-5-21 X B
22 PRC-8-5-22 X B
23 PRC-8-5-23 X B
24 PRC-8-5-24 X B
25 PRC-8-5-25 X B
26 PRC-8-5-26 X B
27 PRC-8-5-27 X B
28 PRC-8-5-28 X B
29 PRC-8-5-29 X B
30 PRC-8-5-30 X B
31 PRC-8-5-31 X B
32 PRC-8-5-32 X B
33 PRC-8-5-33 X B
34 PRC-8-5-34 X B
35 PRC-8-5-35 X B
36 PRC-8-5-36 X B
37 PRC-8-5-37 X B
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
N Y
S
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 31, 2025 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Appendix C
Photo Log
PHOTO 1: Provo Regional Building
PHOTO 2: Spray-on Fireproofing contains asbestos
R & R Environmental, Inc.
47 West 9000 South, Suite #2, Sandy, Utah 84070
(801) 352-2380 • Fax: (801) 352-2381
SITE PHOTOGRAPHS
AN ASBESTOS SURVEY AND ASSESSMENT
OF THE
UTAH STATE GOVERNMENT
PROVO REGIONAL BUILDING
PROJECT NO:
DESIGNED BY:
SCALE:
REVIEWED BY:
DRAWN BY:
DATE:
FILE:
Appendix D
State of Utah Certification
Utah Lead-Based Paint Certification
State of Utah
SPENCER J. COX
Go,·tmor
DEIDRE HENDERSON
litutenant Gol'limor
February 11, 2025
Steve Smith
Department of Environmental Quality
Kimberly D. Shelley Exec11tfre Director
DIVISION OF AIR QUALITY
Bryce C Bird
Director
R&R Environmental, Inc.
4 7 West 9000 South, #2 Sandy, UT 84070
Dear Mr. Smith:
Re: Utah Lead-Based Paint Program Individual Certification Card
Inspector l Risk Aue
-4~;_·~
Director, Utah D1v1sion of Air Quality
DAQA-002-25
The Utah Division of Air Quality (DAQ) has reviewed your Utah Lead-Based Paint (LBP)
Program Certification Application for Individuals and we are pleased to inform you that your application has been approved. Your new LBP program individual certification card is enclosed with this letter and this card is the sole method of individual certification documentation that you will receive from the DAQ.
Please check the information on your LBP program certification card carefully.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .