ATCT Modernization Design Data Handbook (pdf)

View the file

Other files

File Type Posted
FLS Specs.pdf PDF
Railing Specs and Drawings.pdf PDF
ATCT Modernization Drawings.pdf PDF
Amendment #1.pdf PDF
DOL Wage Rates.pdf PDF
Sample Construction Waste management submittal.xls XLS spreadsheet
Business Declaration Form.pdf PDF
FLS Drawings.pdf PDF
RFO Package.pdf PDF
ATCT Modernization Specs.pdf PDF
ATCT Modernization Design Data Handbook.pdf PDF
Business Declaration Form.pdf PDF
RFO Package.pdf PDF
DOL Wage Rates.pdf PDF
ATCT Modernization Design Data Handbook.pdf PDF
ATCT Modernization Drawings.pdf PDF
FLS Specs.pdf PDF
FLS Drawings.pdf PDF
Railing Specs and Drawings.pdf PDF
ATCT Modernization Specs.pdf PDF
Sample Construction Waste management submittal.xls XLS spreadsheet
Railing Specs and Drawings.pdf PDF
RFO Package.pdf PDF
ATCT Modernization Drawings.pdf PDF
Business Declaration Form.pdf PDF
FLS Specs.pdf PDF
Sample Construction Waste management submittal.xls XLS spreadsheet
DOL Wage Rates.pdf PDF
FLS Drawings.pdf PDF
ATCT Modernization Specs.pdf PDF
ATCT Modernization Design Data Handbook.pdf PDF
Business Declaration Form.pdf PDF
ATCT Modernization Drawings.pdf PDF
FLS Drawings.pdf PDF
Railing Specs and Drawings.pdf PDF
DOL Wage Rates.pdf PDF
ATCT Modernization Specs.pdf PDF
FLS Specs.pdf PDF
Sample Construction Waste management submittal.xls XLS spreadsheet
RFO Package.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Major Modernization of the DAB ATCT Daytona Beach International Airport, FL for the

US Department of Transportation Federal Aviation Administration

Design Data Handbook

Burns & McDonnell Engineering Co., Inc.

Alpharetta, Georgia

December 2017 BMCD Project Number: 82773

US DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

MAJOR MODERNIZATION OF THE DAB ATCT

DAYTONA BEACH INTERNATIONAL AIRPORT, FLORIDA

BMcD PROJECT # 82773

INDEX AND CERTIFICATION PAGE - 1

INDEX AND CERTIFICATION PAGE

REPORT INDEX

DOCUMENT/

DIVISION DESCRIPTION

1 General 2 Civil 3 Architectural 4 Structural 5 Mechanical 6 Stairwell Pressurization System and Associated Fire/Life Safety 7 Electrical Appendix A Specification Outline Appendix B Lighting Calculations Appendix C Stairwell Pressurization Calculations Appendix D Civil Calculations Appendix E Mechanical Calculations and Cutsheets Appendix F Plumbing Calculations and Cutsheets Appendix G Meeting Notes

Major Modernization of the DAB ATCT US Dept. of Transportation Daytona Beach International Airport, FL Federal Aviation Administration

Design Submittal TOC

Daytona Beach Air Traffic Control Tower

Table of Contents

1. General

2. Site/Civil

3. Architectural

4. Structural

5. Mechanical

6. Stairwell Pressurization System and Associated Fire/Life Safety

7. Electrical

Appendix A – Specification Outline

Appendix B – Electrical Calculations and Cutsheets

Appendix C – Stairwell Pressurization Calculations

Appendix D – Civil Calculations

Appendix E – Mechanical Calculations and Cutsheets

Appendix F – Plumbing Calculations and Cutsheets

Appendix G – Meeting Notes

Design Submittal 1 December 2017

GENERAL

1) Introduction The purpose of this project is to design, create construction documents, and prepare a cost estimate for the modernization of the ATCT and base building. The ATCT work primarily consists of upgrading fixtures and finishes in unisex restroom, upgrading finishes in the 4th level lobby, replacement of carpet in the CAB, replacement of selected windows, sealing selected louvers, repainting tower stairwell, replacement of water pressure pump and roof replacement. The base building work primarily includes a restroom reconstruction, addition of a unisex shower, addition of a stairwell pressurization system, upgrading interior finishes, sound absorbing panel replacement in TRACON, addition of roof handrails, roof replacement, repair of miscellaneous storm damaged features (e.g., canopy, downspout, and door seals) and other minor repairs and modifications.

Exterior work primarily consists of resealing & painting the ATCT and base building, replacement of sanitary lift station, replacement of the sanitary force main, regrading the northwest area adjacent to the ATCT, regrading the entrance to the base building, resealing the parking lot and replacing parking lot light fixtures.

2) Environmental The FAA performed a recent asbestos audit (Fall 2017) and determined that there are no asbestos containing materials (ACM) likely contained within the roofing materials. Lead-based paint is assumed to be contained throughout the facility. The lead-based paint will be encountered during the demolition of the restroom and is not uncommon for contractors to address. Specifications have been prepared to provide appropriate direction to the Contractor for demolition of the lead-based paint.

3) Construction Cost A construction budget has not been provided by the FAA. A detailed construction cost estimate has been performed using MII which is the second generation of the Micro-Computer Aided Cost Estimating System (MCACES) based on the previously submitted final design. MII provides an integrated cost estimating system (software and databases) that meets the U.S. Army Corps of Engineers (USACE) requirements for preparing cost estimates. A cost estimate for the additional scope items within design modifications #2 and #3 will be prepared.

4) Schedule

a. Design Schedule

i. NTP – 2/13/2015

ii. Design Modification NTP – 8/6/2015

iii. 70% Design Submittal – 10/15/2015

iv. 70% Review Meeting – 1/6/2016

v. 100% Design Submittal – 1/29/2016

vi. Final Design/Ready to Advertise Submittal – 3/18/2016

vii. 70% Design Submittal (Revised SOW) – 7/11/17

viii. 70% Review Meeting – 8/2/17

ix. 100% Design Submittal (Revised SOW) – 11/7/17

x. 100% Review Meeting – Meeting was not deemed as necessary

xi. Final Design/Ready to Advertise Submittal – 12/8/17

Design Submittal 2

b. Construction Phasing The construction project will require a phased reconstruction approach since the ATCT and Base Building will be operational during construction. Since the facility’s restroom, sanitary lift station and sanitary force main are being reconstructed, a temporary modular-type restroom is specified to be provided. The construction specifications are currently drafted such that the construction contractor is to develop a phasing plan for approval by the FAA prior to starting construction. The FAA will need to confirm that this approach is acceptable during the review meeting.

5) Permits This project will require various permits given the nature of some of the elements being reconstructed. The following permits are anticipated:

Short Term Dewatering Permit (St. Johns River Water Management District) Wastewater / Sewage Treatment Capacity Approval / Sewer Application Sign-off (Volusia County Utilities

Department; Florida Department of Environmental Protection – Central District) NPDES – Small construction activity NOI (Florida Department of Environmental Protection)

6) CADD

Microstation V8 was utilized to produce construction drawings. FAA Order 002g, Standard Engineering Drawing Preparation and Support, was used as a guide for the preparation of construction drawings.

Design Submittal 3

SITE/CIVIL

1) Design Criteria The following criteria shall be used in the design of this project:

FAA ATO December 2012 Terminal Facilities Standard Designs A/E Project Manual FAA

2) Overview As part of the ATCT Major Modernization project at the Daytona Beach International Airport, the FAA contracted Burns & McDonnell to assess and design repairs to the existing sanitary sewer outfall line, replace the existing sanitary sewer pump station, installation of drainage inlets and pipes, minor grading design for storm drainage and associated force main, and reseal and restripe the parking lot. A vicinity and location map of the FAA ATCT is shown in Figure 1 below; and an aerial photograph is shown in Figure 2.

Figure 1: DAB FAA ATCT Vicinity Map

FAA ATCT

Daytona Beach International Airport

NORTH

Design Submittal 4

Figure 2: DAB FAA ATCT Aerial Photograph

An existing 4” sanitary sewer line services the existing ATCT and Base Building and discharges into an existing wastewater pump station located approximately 175 feet west of the existing buildings. The existing 4” sanitary sewer line is cast iron pipe installed during the original base building construction in 1980. The original gravity line discharged to a septic tank and leach field located west of the existing POV parking lot; however, a pump station replaced the septic tank in 2002 and pumped the wastewater through a 3” PVC force main to an existing 3” force main located approximately 1700 linear feet further west of the site. A CCTV video inspection of the existing gravity pipe was performed to verify its current condition. The existing pipe exhibited signs of corrosion and scaling. Furthermore, there are two sags or low points in the existing gravity line between the building and the pump station and a longitudinal displacement at a pipe joint.

Base Building

ATCT

NORTH

Pump Station

Design Submittal 5

Figure 3: Sanitary Sewer Outfall Pipe Scaling / Corrosion

Design Submittal 6 December 2017

Figure 4: Offset Pipe Joints

3) Demolition

a) Sanitary Sewer Due to the age and condition of the existing gravity line, the existing 4” gravity cast iron pipe will be demolished and replaced. Additionally, in accordance with the FAA request, the sanitary sewer pump station and control panel to be demolished and replaced.

b) Site The facility users have reported that ponding occurs during storm events at the south entrance of the building. To prevent this, the landscape planters will be removed on either side of the entrance.

4) New Work

a) Sanitary Sewer Outfall

The existing 4” cast iron pipe providing sanitary sewer service to the base building will be demolished, removed, and replaced with a new 6” PVC gravity line that will tie into the base building plumbing. The 6” line will generally follow the existing 4” cast iron pipe alignment and discharge into a new sanitary sewer lift station.

b) Sanitary Sewer Lift Station

Design Submittal 7

The new sanitary sewer lift station will be a duplex, packaged wastewater pump station. The wet well will be constructed of reinforced concrete anchored to an anti-floatation slab. See the Appendices to this document for wet well buoyancy calculations. The structures will be light-duty rated for pedestrians and mowers with an aluminum access hatch centered over the pumps. Alternative wet well designs proposed by the Contractor will be submitted for approval by the FAA and Engineer.

The pump station will contain two submersible, explosion-proof grinder pumps operating in an alternating manner and are capable of grinding solids to ¼” diameter for conveyance in the 2-inch force main. An emergency high-level alarm will be activated when the wet-well volume reaches one foot above the pump-on volume which will activate both pumps to operate simultaneously. All pump components, except for pump controls, will be contained within the wet well. Quick disconnects, guide rails, and lifting chains will allow for maintenance and removal or equipment. The new duplex pumps will be capable of pumping 44 GPM at 65 feet of head. The pumps will have capacity to handle the additional volume resulting from the new shower in the base building (see Mechanical and Architectural Sections for additional information). See the Appendices to this document for examples of pumps on Volusia County’s approved list.

The new pumps will not increase the flow downstream of the new system. According to the City of Daytona Beach utility bills provided from February 2015 thru April 2015, the total water usage for the ATCT and Base Building was 34600 gallons or an average flow rate of 0.38 GPM. A new 2” force main will replace the existing 3” force main and will generally follow the existing route of the existing force main.

At 44 GPM, new 2” force main will flow at 4.5 feet per second. Ultimately, the new system ties into an existing 6” force main which, further downstream, ties into an existing 36” force main. The existing 3” force main will be abandoned-in-place. No analysis of how the new system will impact the existing force mains or associated lift stations was conducted as no information for these systems was available. See the Appendices to this document for total dynamic head calculations for the new system.

c) POV Parking Lot Restriping The existing POV parking lot located south and west of the ATCT and base building will be seal coated and restriped. The parking lot includes four ADA parking spaces and 70 standard employee vehicle parking spaces.

d) Storm Drain Inlets and Piping Currently during rainfall events, water will pond in the west entrance of the building between the ATCT and the screen porch. The concrete here will be removed and replaced to provide a trench drain with the concrete sloping towards it to provide drainage. Ponding also occurs on the north face of the building, due to the roof drain downspouts. Two yard inlets will be provided here. The piping for the new storm drainage system will be 6” PVC. The new system will tie into an existing drop inlet to the west of the building along the access road.

Design Submittal 8

e) Grading As mentioned before, during rainfall events water is trapped and ponds along the south entrance of the building in the landscaping. After the planters are demolished, this area will be graded to provide positive drainage away from the building entrance.

5) Construction Phasing

The phases of construction are generally described below:

Phase 1 – Interior renovations and sanitary sewer outfall replacement o All interior electrical, mechanical, and architectural work associated with the interior renovations will be conducted in Phase 1. A temporary, trailer restroom will be provided during the bathroom renovations for employee use.

Phase 2 o Re-seal and restripe the POV parking lot

Contractor access will be through the northern ATCT entrance off Bellevue Ave. The contractor will cordon off the construction area using lighted temporary barricades.

This phase is broken into three sub-phases to minimize the parking lot closure time.

o The sanitary sewer outfall line, pump station replacement and force main.

o Storm drainage and grading improvements

Design Submittal 9

ARCHITECTURAL

1) Design Criteria The following criteria shall be used in the design of this project:

ADA, ABA, ADAAG Americans with Disabilities Act, Architectural Barriers Act, Accessibility Guidelines for Buildings and Facilities IBC International Building Code, 2012 Edition NFPA 101 Life Safety Code, 2012 Edition ASTM Standards American Society of Testing and Materials ANSI American National Standards Institute OSHA Occupational Safety and Health Administration FAA ATO December 2012 Terminal Facilities Standard Designs A/E Project Manual

2) Overview The architectural scope of work includes demolition and reconstruction of the primary restrooms and updating the architectural finishes in the administrative areas and equipment room number 127 within the base building and removing selective walls and infilling doors. The control tower work will include updating fixtures and finishes in the tower unisex restroom, upgrading finishes in the 4th level lobby, and painting in the tower stairwell. The exterior architectural items include the replacement of the roof for the base building, Link, UPS and buildings, repairing the roof at the tower cab and catwalk, repairing to canopy over the door to the base building roof, the replacement of five windows at the tower and link areas, the replacement of four doors at the base building, adding guardrails at the base building roof, replacing exterior sealant and repainting for the tower, base building and UPS Building.

3) Base Building The existing bathrooms, janitor closet, and NATCA rooms will be demolished and redesigned to meet ADA code and allow for the addition of a unisex shower. Interior partition walls between rooms 111/120 office and 115/116 will be removed and the rooms consolidated accordingly. The administrative areas of the building will receive updated finishes, including new paint, ceiling tiles, vinyl composition floor tiles or carpet tiles and base.

The corridors, including the link and elevator lobby on the first floor will also receive similar new finishes. The lighting fixtures in these areas will be updated as well. The TRACON room will receive new sound absorbing wall panels. One window in the Link portion of the base building will be replaced. There are six doors that will be replaced and /or receive new hardware to provide additional fire rating or weather protection for the rooms where they are located.

The base building roof will require complete removal and replacement with a new fully adhered single ply TPO (Thermoplastic Olefin) roof. The roof over the locker room addition will also be repaired with a TPO roof system. Guardrails will be installed where missing around the perimeter of the roof to fulfill code requirements.

4) Control Tower The stairwells in the control tower will be repainted and several windows will be replaced. The door and frame providing access to the base building roof from the tower will be replaced. On the 4th floor level of the tower the unisex bathroom finishes will be removed and updated with new fixtures, casework, paint, floor tiles and base. The lobby area at the 4th floor will also receive new wall paint and ACT. Door hardware associated with the stairwell will be replaced as needed. The door assembly leading to the ATCT Cab will be replaced. The

Design Submittal 10 December 2017 catwalk will be resurfaced with new epoxy and the existing roof of the control cab will be removed and replaced with a single ply fully adhered TPO roof system. Three l windows in the tower will also be removed and replaced.

Four existing exterior louvers will be removed and sealed while one window is being replaced with a hurricane-rated louver and window assembly. Additional louvers and goose neck intake louvers at the Tower Cab and Cab Roof Level will also be removed and sealed. Refer to the Stairwell Pressurization system description regards to a new louver in the ATCT.

5) UPS Building The existing building roof will be removed and replaced with a single ply fully adhered TPO roof system.

6) Exterior The joint sealant for all buildings (tower, base building, link and UPS) will be replaced prior to pressure washing.

All building exteriors will be repainted with a high performance textured coating.

Design Submittal 11 December 2017

STRUCTURAL

1) Design Criteria The following criteria shall be used in the design of this project:

IBC International Building Code, 2012 Edition ASCE 7-10 Minimum Design Loads for Buildings and Other Structures ACI 318-11 Building Code Requirements for Structural Concrete ASTM Standards American Society of Testing and Materials ANSI American National Standards Institute FAA ATO December 2012 Terminal Facilities Standard Designs A/E Project Manual

2) Overview The structural scope of work includes demolition and reconstruction of the base building restroom slab on grade. The new slab on grade will be depressed to allow for thick set tile. Additional slab-on-grade concrete slab repair is included to repair areas when utilities are replaced/installed below the floor.

3) Design Loads The following loads apply to this project:

a. Live Load:

1. First Floor 100 psf

b. Wind Loads:

1. Ultimate Design Wind Speed, Vult: 147 mph

2. Nominal Design Wind Speed, Vasd: 114 mph

3. Exposure Category: C

4. Occupancy Category: IV

c. Seismic Loads:

1. Mapped 0.2s Spectral Response Acceleration, Ss: 0.082g

2. Mapped 1.0s Spectral Response Acceleration, S1: 0.044g

3. Site Class: D (Assumed)

4. Occupancy Category: IV

5. Design 0.2s Spectral Response Acceleration, Ssds: 0.087g

6. Design 1.0s Spectral Response Acceleration, Sd1: 0.070g

7. Seismic Importance Factor, Ie 1.50

8. Seismic Design Category C

Design Submittal 12

Mechanical:

Design Criteria

The following criteria shall be used in the design of this project:

2012 IMC International Mechanical Code ASHRAE Handbooks 2013 Fundamentals Volume ASHRAE Standard 62.1-2010 Ventilation for Acceptable Indoor Air Quality ASHRAE Standard 90.1-2010 Energy Standard for Buildings Except Low-Rise Residential Buildings ASHRAE Standard 189.1-2011 Standard for the Design of High-Performance Green Buildings Except

Low-Rise Residential Buildings ASTM Standards American Society of Testing and Materials EPAct 2005 Energy Policy Act of 2005 (Public Law 109-58) NFPA 90A - 2012 Edition Standard for the Installation of Air Conditioning and Ventilating Systems SMACNA Guidelines Sheet Metal and Air-Conditioning Contractors' National Association FAA ATO December 202 Terminal Facilities Standard Designs A/E Project Manual

Outdoor Design Conditions

Conditions Daytona Beach International Airport, FL are taken from ASHRAE 2013 Fundamentals Volume and are as follows:

Summer Conditions 92.8 °F dry bulb – 0.4%

76.9 °F mean coincident wet bulb – 0.4%

Dehumidification Conditions 83.7 °F mean coincident dry bulb – 0.4%

144.21 grains of moisture per pound of dry air – 0.4% Dew Point 77.7 °F -0.4%

Winter Conditions 39.2 °F dry bulb – 99%

Annual Cooling Degree Days 2992 (Base 65) Annual Heating Degree Days 748 (Base 65)

Location 29.18 °N

81.06 °W

Elevation 43 feet

3) Indoor Design Conditions

Critical Areas: Cooling/Heating: 73°F +/- 2 °F dry bulb

(for periods of 6 hours minimum) Humidity Requirements: 50-55% RH (stable for 6 hours minimum)

Design Submittal 13

Mechanical/Electrical Rooms: Cooling/Heating: 75°F +/- 3 °F dry bulb Winter Humidity Requirements: 35% RH Summer Humidity Requirements: 50-55% RH

Offices, Conference, Break Areas, Cooling/Heating: 75°F +/- 3 °F dry bulb Janitor Closets, Storage, Corridors, Winter Humidity Requirements: 35% RH Administrative Rooms, Restrooms, Summer Humidity Requirements: 50-55% RH Other personnel areas of electronic rooms:

Demolition of Existing HVAC and Plumbing Systems

Demolished scope items will include the following:

1) All plumbing fixtures, domestic cold and hot water piping, sanitary sewer and venting piping, electric water heater, and all related accessories associated with Women Restroom #117 and Men Restroom #119.

2) Existing electric water cooler (relocated).

3) Partial demolition of VAV-7 ductwork serving Women Restroom #117 and Men Restroom #119.

4) Demolition of exhaust fan EF-3 and ductwork serving Women Restroom #117 and Men

Restroom #119. Existing roof curb shall remain.

5) All plumbing fixtures associated with 4th floor Control Tower Lavatory.

6) Demolition of exhaust fan/light/heater serving 4th floor Control Tower Lavatory.

7) Existing water pressure duplex booster pump assembly (P-1, 2).

8) Existing control dampers, wire, & conduit back to nearest junction box at each tower floor vestibule.

New HVAC and Plumbing Scope

New scope items will include the following:

1) Provision of new plumbing fixtures, domestic cold and hot water piping, sanitary sewer and venting piping, electric water heater (relocated), and all related accessories associated with Women Restroom #117 and Men Restroom #119, according to new restroom layouts.

2) Provision of new instantaneous water heaters for shower and, lavatories and mop-basin.

3) Provision of new ductwork and air distribution devices associated with VAV-7 serving Women

Restroom #117 and Men Restroom #119.

4) Provision of new exhaust fan EF-3 and ductwork serving Women Restroom #117 and Men

Restroom #119. Reuse exiting roof curb.

5) Provision of new plumbing fixtures associated with 4th floor Control Tower Lavatory.

6) Provision of new exhaust fan/light/heater serving 4th floor Control Tower Lavatory.

7) Provision of new water pressure duplex booster pump assembly (P-1,2) with VFD

8) Provision of stair pressurization system based on all doors closed.

(1) Provision of inline tube-axial outside air supply fan.

(2) Provision of intake louver and associated ductwork.

Design Submittal 14

Training

Training by factory certified technicians will be required for all HVAC systems. Training in a classroom type setting will include proper operating and maintenance procedures, troubleshooting procedures, routine and overhaul maintenance, testing and balancing, and calibration.

Test and Balance

Base building and ATCT systems will be tested, balanced and adjusted to ensure that the systems are designed, installed, and calibrated to operate effectively.

Design Submittal 15

Stairwell Pressurization System and Associated Fire/Life Safety

1) Design Criteria

The following criteria will be used in the design of this project. Where codes and standards are conflicting, the most stringent code or standard shall apply.

FBC Florida Building Code, 2014 Edition FEBC Florida Existing Building Code, 2014 Edition NFPA 92B Smoke Management Systems in Malls, Atria and Large Spaces, 2009

Edition NFPA 101 Life Safety Code, 2012 Edition HSCE Handbook of Smoke Control Engineering, 2012 Edition FAA ATO Terminal Facilities Standard Designs A/E Project Manual, 2002 Edition ASHRAE Handbook Book of Fundamentals, 2001 Edition

2) Overview

A stairwell pressurization system shall be provided as part of this project. This installation is inclusive of a supply fan, louver, and supporting supervision equipment such as limit switches, a positive airflow switch, and a duct smoke detector. Louvers and openings in the Air Traffic Control Tower (ATCT) will be sealed. Cracks and penetrations that compromise the 2-hour fire resistive rating of the stairwell shaft will be sealed as part of this project. The stairwell leading from the junction level to the cab is separated from the rest of the stairwell and is considered outside of the scope of work in this project. The stair pressurization system will tie into and be controlled by a fire alarm system that is being installed under a separate contract, and not part of this scope of work. However, devices and functionality regarding the stairwell pressurization system will be provided for coordination.

3) Stakeholder Goals

During the design of the stairwell pressurization system, the following goals were determined:

a) Provide a design to minimize the overall quantity of air supplied to the smokeproof enclosure, while still maintaining the minimum pressure differentials required by code.

b) Reduce the maintenance requirements of the system, by designing a system that does not require yearly calibration of equipment to function properly (e.g. differential pressure sensors).

c) Utilize existing openings and space within the ATCT to minimize any structural modifications to the building.

d) Simplify the interface between the stairwell pressurization system, and the fire alarm system which will be under a separate contract.

Design Submittal 16

4) Preliminary Plan Development/Analysis

The preliminary plan development and analysis is focused around defining the type of system which will be provided, and then using analytical formulas found in the Handbook of Smoke Control Engineering and NFPA 92B to estimate the required supply and relief volumetric flow rates. From this preliminary analysis, the following items were determined and incorporated in the plan/design:

a) The fan will be placed under the stairs on the first floor and discharge directly into the stairwell.

b) The existing louvers in the vestibules on floors 2 through 5 will be removed and the openings sealed.

c) The system will be designed under the assumption that all stair doors will be closed.

During the preliminary analysis, the FBC stairwell pressurization requirements were reviewed: Per section

412.3.2 the stairwell inside of an air traffic control tower must be pressurized to not less than 0.15” w.c. and not greater than 0.35” w.c. relative to the vestibule. This design criteria was used as the basis for the supply fan sizing and calculations. FAA has approved the calculations to consider all doors in the stairwell closed.

5) Final Plan Development/Analysis

Due to height of the ATCT stairwell the stack effect was considered, however due to the type of construction of the ATCT, wind was considered to have negligible effect. The height of the stairwell, leakage of the walls, gaps around the doors, and the external temperature drove the pressurization calculation. The following assumptions were made regarding the tower:

a) The stairwell begins on the first floor and extends to the 5th floor. However, the 5th floor stairwell discharges into a narrow corridor with 2 doors on either side. For simplicity, the calculation assumes 5 full flights of stairs.

b) A portion of the stairwell is an exterior wall, and therefore stack effect is considered.

c) The wall leakage is considered loose construction. This is a conservative approach, as fire resistive construction would be considered tight to average construction for leakage.

d) The stairwell doors have a 2” door frame, sweepers, and are gasketed on the top and sides of the door to minimize airflow.

e) The fan damper will be placed as indicated on the mechanical drawings.

f) The air leakage through the stairwell doors into the vestibules will not need to be relieved, per direction from FAA.

6) Stairwell Pressurization System Installation

A Variable Frequency Drive (VFD) supply fan will be provided on the first floor. The VFD is provided for more precise balancing of airflows during commissioning and will not be modulated during a fire event. The fan will be located beneath the first set of stairs in the stairwell and will discharge directly into the stairwell.

The first floor supply fan will intake air via a louver installed on the same floor. This louver will be hurricane-proof and meet the requirements of the FBC. The intake velocity will be limited to minimize the infiltration of rain while in operation. A damper will be installed in the ductwork downstream of the louver, but before the fan, and will be interlocked with the supply fan. Protection of the stairwell from smoke infiltration from the outside is via a duct smoke detector downstream of the fan. Upon detection of smoke in the air supply, the duct

Design Submittal 17 smoke detector will override the stairwell pressurization system, shutdown the fan, and close the motorized damper. A pressure switch will be installed downstream of the fan, and will monitor the fan upon activation to verify the fan is operating as intended. Upon increased pressure, a green light should illuminate on the smoke control panel, provided by others.

7) Stairwell Pressurization System Control

The stairwell pressurization system will be monitored and controlled by the fire alarm system which is not part of this Scope of Work. Some non-addressable devices will be provided as part of this project such as limit switches and pressure switches, however addressable devices such as duct smoke detectors will need to be provided as part of the fire alarm Scope of Work. Overall, the devices that need to interface with this system will be provided in a one-line diagram on the plans for coordination, including a general functionally matrix and sequence of operations.

Additional items required by a stairwell pressurization system, but exclusively part of the fire alarm system will not be addressed such as manual controls of the stairwell pressurization system, smoke control panel layout, and survivability and routing of the SLC and 24 VDC power circuits.

Per FBC section 909.12.3, the stair pressurization system will be initiated by manual pull station, smoke detector, and manual activation.

8) Passive Fire Protection – Penetrations

Existing openings in the stairwell shaft currently compromise the integrity of the 2-hour fire-resistive rating.

These openings will be sealed with UL-Listed assemblies where possible. Where this is not possible, the wall will be reconstructed to maintain the fire-resistive rating. Measurements and photos of each of the penetrations were taken and will be used for reference to determine size and method of sealing. These penetrations and the UL-Listed assemblies will be shown on the Architecture Plans.

The hardware on the existing doors into the stairwell will be replaced with adjustable closers. The ability to adjust the closing force during commissioning is important to verify the door fully closes and latches, but at the same time does not exceed the maximum door opening force permitted.

Per FBC Section 909.20.6.1, the equipment and ductwork supplying the stair pressurization system shall have a 2-hour fire-resistive construction or located in a dedicated room with 2-hour construction. The fan and ductwork supplying the fan will be within the 2-hour fire rated stairwell, and therefore no passive fire protection will be required for the mechanical portion of the stair pressurization system.

Design Submittal 18

ELECTRICAL

1) Design Criteria The following criteria shall be used in the design of this project:

ANSI C2 National Electrical Safety Code FAA ATO December 2012 Terminal Facilities Standard Designs A/E Project Manual FAA-C-1217G Federal Aviation Administration Specification ELECTRICAL WORK, INTERIOR FAA-G-2100H Federal Aviation Administration Specification ELECTRONIC EQUIPMENT, GENERAL REQUIREMENTS

FAA-STD-019f Lightning and Surge Protection, Grounding, Bonding and Shielding

Requirements for Facilities and Electronic Equipment IBC International Building Code IEEE 142 Recommended Practice for Grounding of Industrial and Commercial Power Systems IESNA Illuminating Engineering Society of North America Handbook NFPA 70 National Electrical Code (NEC) NFPA 72 National Fire Alarm Code NFPA 101 Life Safety Code NFPA 780 Lightning Protection Code

2) Demolition of Existing Electrical Systems Demolished scope items will include the following:

a. Electrical circuit to existing electric water heater serving Women Restroom #117 and Men Restroom #119.

b. All lighting in Women Restroom #117 and Men Restroom #119.

c. All electrical items on walls to be demolished in Women Restroom #117, Men Restroom #119, Office

Room #111, Office Room #120, Office Room #115 and Office Room #116 .

d. Electrical circuit to existing electric water cooler.

e. Demolition of exhaust fan EF-3 and ductwork serving Women Restroom #117 and Men Restroom

#119.

f. Exhaust fan/light/heater serving 4th floor Control Tower Lavatory.

g. Electrical circuit to existing water pressure duplex booster pump assembly (P-1, 2).

h. All lighting in base building administration type areas, base building corridor, and tower elevator lobby.

i. Exterior site lighting.

j. Remove and replace six out of date emergency light fixtures.

k. Remove elevator sump pump from nonessential power distribution system.

l. Demolish lightning protection system on the roof of the air traffic control tower and the UPS building. Existing down conductors, ground ring and ground rods shall remain in place.

m. Demolish existing lift station controls, disconnect switch and generator receptacle.

Design Submittal 19

3) New Work Electrical Scope New scope items will include the following:

a. Electrical circuits for electronic sensors for new plumbing fixtures and electric water heater associated with Women Restroom #117 and Men Restroom #119, according to new restroom layouts.

b. Electrical circuits for new instantaneous water heaters for shower and, lavatories and map-basin.

c. Electrical circuits for new exhaust fan EF-3 serving Women Restroom #117 and Men Restroom #119.

d. Electrical circuits for electronic sensors for new plumbing fixture and new exhaust fan/light/heater associated with 4th floor Control Tower Lavatory.

e. Electrical circuit for new water pressure duplex booster pump assembly (P-1, 2) with VFD.

f. New LED type light fixtures in base building administration type areas, base building corridor, and tower elevator lobby.

g. New LED exterior site lighting to be installed on existing light poles and surface mounted on the building.

h. Remove and replace six out of date emergency light fixtures.

i. Provide electrical circuit to elevator sump pump from essential power distribution system.

j. Provide grounding connection to electrostatic floor systems in the base building room 127 and the tower cab level.

k. Provide electrical circuit to the new stairwell pressurization fan.

l. Install new lightning protection system on the roof of the air traffic control tower and the UPS building. New lightning protection system on roof shall be connected to the existing down conductors. A new UL Master Label certificate shall be provided for the lightning protection system.

The lightning protection system shall meet the requirements of NFPA 780 and FAA-STD-019f.

m. New lift station controls, disconnect switch, manual transfer switch and generator receptacle.

n. New hand dryers in Women Restroom #117 and Men Restroom #119.

o. New receptacles and telecom outlets at the base building first floor sign-in desk space and the separate computer counter.

p.

4) New Interior Power

a. New receptacles and wiring devices will be provided as required based on the locations of new workstations and other office equipment.

5) Interior Grounding

a. Grounding will be in accordance with the NFPA 70 (NEC) and ANSI/EIA/TIA 607. All feeder and branch circuits will have a "green" insulated equipment ground conductor in addition to the conduit being used as a grounding path.

Design Submittal 20

6) Wiring and Conduit

a. Threaded, galvanized, rigid steel conduit or intermediate metal conduit will be used in all exposed, outdoor, and hazardous locations.

b. Extruded metal tubing (EMT) with compression fittings will be installed indoors, in non-hazardous locations, above suspended ceilings, and in walls.

c. All conductors will be copper.

d. All conductors #10 AWG and smaller will be solid conductor. All conductors #8 AWG and larger will be stranded conductor.

e. All 600-volt service entrance, feeder and branch circuit wire will be single-conductor and have THWN/THHN insulation.

7) Interior Lighting

a. New lighting will be provided in all office and administrative areas as indicated by the scope of work. The lighting controls will be reconfigured based on the requirements of each space.

b. Lighting levels will meet the recommended levels specified in the Illuminating Engineering Society (IES) handbook. The facility will primarily use the following types of fixtures:

a) 2’ x 4’ recessed LED fixtures in administrative areas and other rooms with acoustical tile ceiling.

b) LED can downlighting in conference rooms.

c. Switching in all private offices will be provided with wall mounted occupancy sensors.

Design Submittal 21

APPENDIX A - SPECIFICATION OUTLINE

MAJOR MODERNIZATION OF THE DAB ATCT DECEMBER 2017

DAYTONA BEACH INTERNATIONAL AIRPORT, FL

TABLE OF CONTENTS 00 01 10 - 1

TABLE OF CONTENTS

DIVISION 01 - GENERAL CONDITIONS

01 00 00 GENERAL PARAGRAPHS

01 10 00 SUMMARY OF WORK

01 10 12 CONSTRUCTION ADMINISTRATION FORMS

01 10 15 ACRONYMS AND DEFINITIONS

01 14 00 CONDITION AFFECTING WORK

01 18 00 EXISTING UTILITIES

01 25 00 SUBSTITUTION PROCEDURES

01 31 19 PROJECT MEETINGS

01 32 00.20 CONTRACTOR-PREPARED CONSTRUCTION SCHEDULE

01 33 00 SUBMITTAL PROCEDURES

01 40 00 CONTRACTOR QUALITY CONTROL

01 42 00 REFERENCES

01 50 00 TEMPORARY FACILITIES AND CONTROLS

01 52 16 SAFETY REQUIREMENTS

01 55 26 MAINTENANCE OF TRAFFIC

01 56 23 BARRIERS AND ENCLOSURES

01 57 13 TEMPORARY AIR AND WATER POLLUTION, SOIL EROSION, AND SILTATION

CONTROL

01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS

01 58 00 CONSTRUCTION IDENTIFICATION SIGNS

01 58 13 POSTING OF NOTICES

01 71 23 SURVEYING AND FIELD ENGINEERING

01 71 33 PROTECTION OF WORK AND PROPERTY

01 74 13 CONSTRUCTION CLEANING

01 77 00 CLOSEOUT PROCEDURES

01 77 10 FINAL CLEANING

01 78 23 OPERATION AND MAINTENANCE DATA

01 78 36 WARRANTIES AND GUARANTEES

01 78 39 PROJECT RECORD DOCUMENTS

DIVISION 02 - EXISTING CONDITIONS

02 01 00 INTERIM LIFE SAFETY MEASURES FOR FACILITIES UNDER CONSTRUCTION

02 03 00 GENERAL REQUIREMENTS FOR DEMOLITION AND RENOVATION

02 83 33.10 LEAD BASED PAINT ACTIVITIES

DIVISION 03 – CONCRETE

03 30 00 CAST IN PLACE CONCRETE

DIVISION 04 – MASONRY (NOT USED)

DIVISION 05 - METALS

05 50 00 METAL FABRICATIONS

05 52 00 ROOF EDGE PROTECTION

TABLE OF CONTENTS 00 01 10 - 2

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

06 10 00 ROUGH CARPENTRY

06 40 23 INTERIOR ARCHITECTURAL WOODWORK

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 01 50 PREPARATION FOR RE-ROOFING

07 19 00 WATER REPELLENTS

07 21 00 THERMAL INSULATION

07 54 00 THERMOPLASTIC MEMBRANE ROOFING

07 57 00 WATERPROOF DECK COATING

07 62 00 SHEET METAL FLASHING AND TRIM

07 72 00 ROOF ACCESSORIES

07 84 00 FIRESTOPPING

07 92 00 JOINT SEALANTS

07 95 00 EXPANSION CONTROL

DIVISION 08 - OPENINGS

08 11 13 HOLLOW METAL DOORS AND FRAMES

08 14 16 FLUSH WOOD DOORS

08 31 13 ACCESS DOORS AND FRAMES

08 39 54 BLAST RESISTANT DOORS

08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS

08 51 13 ALUMINUM WINDOWS

08 71 00 DOOR HARDWARE

08 80 00 GLAZING

08 83 00 MIRRORS

08 91 00 LOUVERS AND VENTS

DIVISION 09 - FINISHES

09 21 16.23 GYPSUM BOARD SHAFT WALL ASSEMBLIES

09 22 16 NON-STRUCTURAL METAL FRAMING

09 29 00 GYPSUM BOARD

09 30 00 TILING

09 51 13 ACOUSTICAL PANEL CEILINGS

09 65 13 RESILIENT BASE AND ACCESSORIES

09 65 19 RESILIENT TILE FLOORING

09 65 36 STATIC-CONTROL RESILIENT FLOORING

09 68 13 TILE CARPETING

09 68 13.10 CONDUCTIVE TILE CARPETING

09 84 13 FIXED SOUND -ABSORPTIVE PANELS

09 91 00 PAINTING

09 94 13.10 TEXTURE FINISHING WITH SOLAR REFLECTANCE

DIVISION 10 - SPECIALTIES

10 21 13 TOILET COMPARTMENTS

10 28 00 TOILET, BATH, AND LAUNDRY ACCESSORIES

10 51 13 METAL LOCKERS

TABLE OF CONTENTS 00 01 10 - 3

DIVISION 11 – EQUIPMENT (NOT USED)

DIVISION 12 – FURNISHINGS (NOT USED)

DIVISION 13 - SPECIAL CONSTRUCTION (NOT USED)

DIVISION 14 - CONVEYING EQUIPMENT (NOT USED)

DIVISION 21 - FIRE SUPPRESSION (NOT USED)

DIVISION 22 - PLUMBING

22 05 00 COMMON WORK RESULTS FOR PLUMBING

22 05 19 METERS AND GAGES FOR PLUMBING PIPING

22 05 23 GENERAL-DUTY VALVES FOR PLUMBING PIPING

22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

22 05 48 VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

22 05 53 IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

22 07 00 PLUMBING INSULATION

22 11 16 DOMESTIC WATER PIPING

22 11 19 DOMESTIC WATER PIPING SPECIALTIES

22 11 23 DOMESTIC WATER PUMPS

22 13 16 SANITARY WASTE AND VENT PIPING

22 13 19 SANITARY WASTE PIPING SPECIALTIES

22 33 00 ELECTRIC DOMESTIC WATER HEATERS

22 40 00 PLUMBING FIXTURES

DIVISION 23 - HEATING VENTILATING AND AIR CONDITIONING

23 05 00 COMMON WORK RESULTS FOR HVAC

23 05 13 COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

23 05 48 VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

23 05 93 TESTING, ADJUSTING, AND BALANCING

23 07 00 HVAC INSULATION

23 08 25 HVAC COMMISSIONING-LIFE SAFETY SYSTEMS

23 31 13 METAL DUCTS

23 33 00 AIR DUCT ACCESSORIES

23 34 23 HVAC POWER VENTILATORS

DIVISION 26 - ELECTRICAL

26 05 00 COMMON WORK RESULTS FOR ELECTRICAL

26 05 05 SUBMITTAL REQUIREMENTS FOR LOCK OUT TAG OUT PROCEDURES

26 05 19 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

26 05 26 GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

26 05 33 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

26 05 48 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

TABLE OF CONTENTS 00 01 10 - 4

26 05 53 26 09 23 26 27 26 26 28 13 26 28 16 26 29 13 26 29 23 26 36 00 26 41 13 26 43 13 26 51 00 26 56 00

IDENTIFICATION FOR ELECTRICAL SYSTEMS

LIGHTING CONTROL DEVICES

WIRING DEVICES

FUSES

ENCLOSED SWITCHES AND CIRCUIT BREAKERS

ENCLOSED CONTROLLERS

VARIABLE-FREQUENCY MOTOR CONTROLLERS

TRANSFER SWITCHES

LIGHTNING PROTECTION FOR STRUCTURES

SURGE PROTECTION DEVICES (SPD)

INTERIOR LIGHTING

EXTERIOR LIGHTING

DIVISION 27 – COMMUNICATIONS (NOT USED)

DIVISION 28 - ELECTRONIC SAFETY AND SECURITY (NOT USED)

DIVISION 31 - EARTHWORK

31 10 00 SITE CLEARING

31 20 00 EARTH MOVING

31 50 00 EXCAVATION SUPPORT AND PROTECTION

DIVISION 32 - EXTERIOR IMPROVEMENTS

32 12 16 ASPHALT PAVING

32 16 00 CURBS, GUTTERS, AND SIDEWALKS

32 92 01 GRASSING BY SODDING

DIVISION 33 - UTILITIES

33 05 13 MANHOLES AND UTILITY STRUCTURES

33 11 00 PRESSURE PIPE

33 11 50 PIPE INSTALLATION

33 12 16 UTILITY VALVES AND ACCESSORIES

33 12 23 LIFT STATION

33 31 00 GRAVITY PIPE

Design Submittal 22

APPENDIX B – ELECTRICAL CALCULATIONS AND CUTSHEETS

Designer

Date

Scale

Drawing No.

DTP

Dec 4 2017

D A

Y T

O N

A B

E A

C H

A

T C

T M

O D

E R

N

IZ

A T

IO

N

E X

T E

R

IO

R L

IG

H

T

IN

G C

A L

C S

LUMINAIRE SCHEDULE

Symbol Label Qty File Lumens LLF WattsCatalog Number Description Lamp

E1 7 VP-L-80NB-

235-4K-T3.ies

Absolute 0.95 235

E2 4 VP-L-80NB-

235-4K- T5W.ies

Absolute 0.95 235

F 1 VP-L-80NB-

235-4K-FR.ies

Absolute 0.95 235

G 1 DDL9Lx-SR.ies Absolute 0.95 39.9

H 6 LC8LED120_8

LCLED535K8.i es

Absolute 0.95 15.5

W1 9 TRV-X-24NB-

27-5K-T3.IES

Absolute 0.95 28.04

W2 3 VBGL1.ies 757 0.95 10.06

VP-L-80NB-235-4K-

T3 LARGE VIPER

C-70-CRI DATA SHOWN

IS SCALED FROM

15.0518

VP-L-80NB-235-4K-

T5W LARGE VIPER

C-70-CRI DATA SHOWN

IS SCALED FROM

15.01501

VP-L-80NB-235-4K-

FR LARGE VIPER

C-70-CRI DATA SHOWN

IS SCALED FROM 3,000

DDL9Lx-SR

LED DUSK TO DAWN, 9

LED, 5100K, SYMMETRIC

WITH REFRACTOR

9 - NICHIA LEDs

LC8LED1208LCLE

D535K8

8 IN Recessed LED Fixture. Housing and Light Engine Assembly

36 - Nichia 3500 K LEDs NCH Color Matched

TRV-X/24NB-

27/5K/T3/UNV JI1408253 1437-16

VBGL1

LED VAPORTITE, 1 COB,

4000K 1 - CITIZEN COB 4000K

Scale

Drawing No.

A

Y T

O N

A B

E A

C

T M

O D

E R

N

IZ

A T

IO

N

E X

T E

R

IO

R L

IG

H

T

IN

G C

A L

C S

STATISTICS

Description Symbol Avg Max Min Max/Min Avg/Min

ATCT WEST

BASE BLDG CANOPY

BASE BLDG EAST

BASE BLDG NORTH

BASE BLDG WEST

DRIVE AISLE CURVE

PARKING NORTH

PARKING WEST

UPS BLDG EAST

UPS BLDG NORTH

UPS BLDG SOUTH

1.1 fc 2.6 fc 0.3 fc 8.7:1 3.7:1

15.5 fc 27.8 fc 4.0 fc 7.0:1 3.9:1

3.5 fc 6.8 fc 0.7 fc 9.7:1 5.0:1

4.5 fc 7.0 fc 1.8 fc 3.9:1 2.5:1

1.5 fc 2.8 fc 0.7 fc 4.0:1 2.1:1

0.3 fc 1.5 fc 0.1 fc 15.0:1 3.0:1

7.5 fc 23.0 fc 0.4 fc 57.5:1 18.8:1

1.8 fc 7.4 fc 0.1 fc 74.0:1 18.0:1

3.7 fc 9.3 fc 0.6 fc 15.5:1 6.2:1

4.3 fc 27.6 fc 0.5 fc 55.2:1 8.6:1

5.3 fc 7.2 fc 2.9 fc 2.5:1 1.8:1

9.0 fc 11.8 fc 5.9 fc 2.0:1 1.5:1

4.1 fc 5.2 fc 3.1 fc 1.7:1 1.3:1

LINK SOUTH

PARKING SOUTH

Scale

Drawing No.

A

Y T

O N

A B

E A

C

T M

O D

E R

N

IZ

A T

IO

N

E X

T E

R

IO

R L

IG

H

T

IN

G C

A L

C S

2.8

2.4

2.4

3.3

3.0

3.0

2.9

2.0

2.0

2.2

2.0

1.7

1.5

1.2

1.1

1.0

0.8

0.7

3.8

2.6

2.5

3.4

4.8

5.1

3.1

2.1

2.0

2.8

2.8

2.4

1.9

1.4

1.1

0.9

0.8

5.4

4.3

3.7

3.7

7.0

6.6

3.3

3.1

3.2

3.8

3.7

3.0

2.4

1.8

1.4

1.1

0.9

0.7

6.7

6.6

7.1

7.0

6.8

6.6

6.6

6.2

5.2

4.8

4.2

3.6

2.9

2.3

1.8

1.4

1.1

0.9

6.9

6.9

7.4

6.8

6.0

5.7

6.3

6.6

5.7

5.2

4.4

3.5

2.8

2.3

2.0

1.7

1.3

1.1

7.0

7.3

7.8

7.6

7.4

7.3

7.2

7.1

6.4

5.5

4.5

3.7

2.9

2.5

2.1

1.8

1.5

1.2

6.7

7.3

8.1

8.3

8.5

8.4

8.1

7.6

6.5

5.4

4.4

3.6

3.0

2.6

2.3

2.0

1.7

1.4

7.1

7.7

8.2

8.7

9.1

9.0

8.4

7.8

6.9

5.9

4.7

4.0

3.3

2.8

2.5

2.1

1.8

1.5

6.2

6.7

7.3

7.6

7.8

7.7

7.4

6.9

6.1

5.3

4.6

3.9

3.4

3.0

2.6

2.3

2.0

1.7

4.8

5.0

5.3

5.6

5.6

5.6

5.5

5.2

4.8

4.4

4.1

3.7

3.4

3.1

2.8

2.4

2.1

1.8

3.5

3.6

3.7

3.9

3.9

4.0

4.0

3.9

3.8

3.8

3.7

3.5

3.4

3.1

2.9

2.6

2.3

1.9

2.7

2.7

2.7

2.8

2.9

3.0

3.1

3.3

3.4

3.5

3.6

3.5

3.5

3.3

3.0

2.8

2.4

2.1

2.3

2.3

2.3

2.3

2.5

2.7

2.9

3.2

3.4

3.6

3.7

3.7

3.7

3.5

3.2

2.9

2.6

2.2

2.1

2.1

2.1

2.2

2.4

2.7

3.0

3.2

3.6

3.8

3.9

3.9

3.9

3.7

3.5

3.1

2.8

2.3

2.0

2.0

2.0

2.2

2.4

2.7

3.1

3.4

3.7

3.9

4.1

4.2

4.0

3.9

3.6

3.3

2.9

2.5

2.0

2.0

2.0

2.2

2.5

2.8

3.2

3.6

3.8

4.0

4.3

4.7

4.3

3.9

3.7

3.5

3.1

2.6

2.0

2.0

2.1

2.3

2.6

2.9

3.3

3.7

3.9

4.1

4.5

5.4

4.5

4.1

3.8

3.6

3.1

2.7

2.1

2.1

2.1

2.3

2.6

3.0

3.3

3.8

4.1

4.3

4.5

4.7

4.5

4.2

4.0

3.7

3.2

2.8

2.1

2.1

2.2

2.4

2.7

3.1

3.4

3.8

4.2

4.3

4.4

4.5

4.4

4.3

4.1

3.7

3.2

2.8

2.2

2.2

2.3

2.4

2.7

3.1

3.4

3.8

4.1

4.4

4.4

4.5

4.4

4.3

4.0

3.6

3.3

2.8

2.2

2.2

2.3

2.5

2.8

3.0

3.4

3.7

3.9

4.2

4.3

4.4

4.3

4.1

3.8

3.6

3.2

2.8

2.2

2.2

2.4

2.6

2.7

3.0

3.3

3.6

3.9

4.1

4.3

4.3

4.2

4.1

3.8

3.5

3.1

2.8

2.3

2.3

2.4

2.6

2.8

3.0

3.3

3.6

3.9

4.1

4.2

4.3

4.2

4.1

3.8

3.5

3.1

2.7

2.2

2.3

2.4

2.6

2.8

3.0

3.3

3.7

3.9

4.1

4.3

4.3

4.2

4.1

3.8

3.5

3.1

2.8

2.3

2.3

2.3

2.5

2.8

3.0

3.4

3.7

4.0

4.2

4.4

4.4

4.3

4.2

3.9

3.5

3.2

2.8

2.2

2.2

2.3

2.4

2.7

3.1

3.4

3.8

4.1

4.3

4.4

4.5

4.4

4.3

4.0

3.6

3.3

2.8

2.2

2.2

2.2

2.4

2.6

3.1

3.4

3.8

4.1

4.3

4.4

4.6

4.4

4.2

4.0

3.7

3.2

2.8

2.1

2.1

2.1

2.3

2.6

3.0

3.3

3.8

4.0

4.2

4.5

4.8

4.5

4.1

3.9

3.6

3.2

2.7

2.0

2.0

2.1

2.2

2.5

2.8

3.2

3.6

3.9

4.1

4.5

5.5

4.5

4.0

3.8

3.5

3.0

2.6

2.0

2.0

2.0

2.2

2.4

2.8

3.2

3.5

3.8

3.9

4.2

4.5

4.2

3.9

3.7

3.4

3.0

2.5

2.0

2.0

2.0

2.1

2.3

2.7

3.0

3.3

3.6

3.8

4.0

4.1

3.9

3.8

3.5

3.2

2.8

2.4

2.0

2.0

2.0

2.1

2.3

2.6

2.9

3.2

3.5

3.7

3.8

3.8

3.7

3.6

3.3

3.0

2.6

2.2

2.2

2.2

2.2

2.3

2.4

2.6

2.9

3.1

3.3

3.5

3.6

3.6

3.5

3.3

3.0

2.7

2.4

2.0

2.9

3.0

2.9

2.9

2.9

3.0

3.1

3.2

3.3

3.3

3.3

3.2

3.1

2.9

2.7

2.4

2.1

1.8

4.4

4.4

4.4

4.2

3.9

3.7

3.6

3.5

3.3

3.3

3.1

3.0

2.8

2.6

2.4

2.1

1.9

1.6

6.2

6.3

6.2

5.8

5.3

4.8

4.3

3.8

3.5

3.2

3.0

2.8

2.5

2.3

2.1

1.9

1.6

1.5

7.9

8.0

7.8

7.5

6.9

5.8

4.9

4.0

3.5

3.1

2.7

2.5

2.2

2.0

1.8

1.6

1.5

1.3

7.6

7.7

7.5

7.2

6.4

5.4

4.6

3.8

3.2

2.8

2.4

2.2

2.0

1.8

1.6

1.4

1.3

1.1

6.9

6.9

6.9

6.9

6.3

5.5

4.6

3.8

3.1

2.6

2.3

2.0

1.8

1.6

1.4

1.3

1.1

0.9

5.3

6.4

5.5

6.3

5.8

5.2

4.5

3.7

3.0

2.5

2.2

1.9

1.6

1.4

1.2

1.0

0.9

0.7

5.2

5.6

5.4

6.4

5.1

4.5

4.2

3.5

2.9

2.4

2.0

7.4

27.8

11.8

5.2

1.5

1.5

7.0

0.5

0.5

1.5

1.5

6.4

11.1

5.1

6.4

15.8

4.9

4.9

12.8

17.223.0

2.6

2.8

2.8

6.8

7.2

0.6

0.1 0.1

4.0 4.0

5.9

3.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

1.8

0.4

0.3

0.7

0.7 0.7

2.9

0.5

0.5

1.9

2.0

1.7

1.3

0.9

2.9

2.8

2.6

2.6

2.2

1.6

1.0

3.6

3.8

3.6

3.3

3.4

2.8

1.9

1.1

4.0

4.5

4.5

4.3

4.6

3.5

2.2

1.2

4.6

5.1

5.4

5.3

5.7

4.2

2.6

1.3

5.8

5.8

6.2

6.3

6.5

4.9

3.0

1.5

5.6

5.2

6.2

6.7

7.0

5.3

3.3

1.6

5.4

5.3

6.3

7.0

5.6

3.4

1.7

5.3

4.7

6.2

6.9

7.3

5.6

3.4

1.6

6.0

5.5

6.2

6.7

6.8

5.2

3.2

1.6

5.6

6.0

6.0

6.2

4.7

2.9

1.5

4.9

5.2

5.0

5.3

4.0

2.5

1.3

4.4

4.3

4.1

4.3

3.3

2.1

1.2

6.4

4.5

2.9

3.4

3.4

3.5

3.4

3.1

3.2

2.6

1.8

1.1

5.7

3.7

2.5

2.6

2.8

2.7

2.6

2.4

2.4

2.1

1.5

1.0

6.0

3.4

1.9

2.0

2.2

2.0

2.0

1.8

1.9

1.7

1.3

0.9

6.7

3.6

1.3

1.5

1.7

1.7

1.6

1.5

1.5

1.4

1.1

0.8

1.4

1.3

1.3

1.2

0.9

0.7

1.3

1.3

1.3

1.1

1.0

0.8

0.6

1.5

1.4

1.1

0.8

0.7

0.5

1.1

0.7

0.5

0.4

1.2

0.6

0.4

0.3

1.4

0.5

0.4

0.3

1.6

0.5

0.3

0.3

1.6

0.4

0.3

0.3

1.6

0.4

0.3

0.3

1.7

0.4

0.2

0.2

0.5

0.2

0.2

0.5

0.3

0.2

0.5

0.3

0.2

0.4

0.2

0.3

0.2

11.6

11.8

21.8

26.6

21.912.5

13.3

7.4

6.4

8.7

9.8

9.5

10.5

10.5

11.5

7.2

11.1

8.5

8.4

8.2

3.7

4.7

3.8 4.1

5.0

4.1

3.9

3.8

1.0

0.7

0.6

0.4

0.3

0.3

0.2

0.2

0.8

0.7

0.5

0.4

0.3

0.3

0.2

0.2

0.6

0.5

0.4

0.4

0.3

0.2

0.2

0.2

0.4

0.4

0.4

0.3

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.2

0.2

0.3

0.3

0.3

0.2

0.4

0.4

0.4

0.3

0.6

0.5

0.5

0.4

0.7

0.7

0.6

0.5

0.9

0.9

0.7

0.5

1.2

1.1

0.9

0.6

1.3

1.0

0.7

4.4

2.7 2.1

2.8

3.1

4.8

4.2

4.9

5.8 5.8

4.4

6.6

6.0

6.0

5.6

5.2

5.7

6.1

4.5

5.9

5.5

5.5

4.3

5.1

4.1

3.6

3.0

3.2

2.6

3.0

0.4

0.6

0.6

0.4

0.8

1.7

1.7

0.4

0.9

2.5

0.8

1.0

0.9

1.0

1.2

1.5

1.8

2.3

1.6

1.1

1.9

1.0

2.1

4.2

3.4

3.9

4.4

2.5

1.4

1.0

1.5

2.6

4.4

3.8

6.3

4.5

4.3

3.2

4.5

0.8

1.5

2.3

3.5

5.2

5.2

5.2

3.9

2.5

1.8

1.3

1.9

2.6

4.1

5.5

5.1

5.0

3.4

3.7

5.9

1.2

1.9

3.7

5.5

5.8

5.5

4.0

2.1

1.5

1.2

1.5

2.3

4.4

6.0

5.9

5.1

3.3

2.9

5.8

5.5

4.7

5.7

5.5

4.7

5.1

7.0

5.6

3.0

4.6

6.7

6.0

4.9

5.8

5.6

4.8

4.9

5.5

5.9

5.1

4.6

3.9

3.1

2.5

2.1

2.0

1.9

1.9

1.9

2.1

2.5

3.2

4.0

4.7

5.3

5.9

5.2

5.9

4.9

5.7

5.5

4.9

4.2

3.4

2.5

1.9

1.5

6.2

6.2

6.3

6.3

6.2

6.3

5.6

4.8

3.9

3.0

2.4

2.1

1.9

1.8

1.8

1.9

2.1

2.5

3.1

3.9

4.8

5.7

6.4

6.3

6.4

6.3

6.4

5.9

5.1

4.1

3.2

2.4

1.8

1.4

6.5

7.0

7.3

7.3

7.0

6.6

5.7

4.6

3.6

2.9

2.3

2.0

1.8

1.8

1.8

1.8

2.0

2.4

3.0

3.7

4.5

5.6

6.5

6.8

7.1

6.9

6.6

5.9

4.9

4.0

3.0

2.3

1.7

1.4

6.6

7.3

7.8

7.8

7.3

6.8

6.0

4.9

3.7

3.0

2.4

2.0

1.8

1.7

1.7

1.8

2.0

2.4

2.9

3.8

4.8

5.9

6.7

7.0

7.3

7.2

6.8

6.1

5.1

4.1

3.0

2.3

1.8

1.4

5.7

6.2

6.7

6.7

6.4

5.9

5.1

4.1

3.4

2.7

2.3

2.0

1.8

1.7

1.7

1.7

1.9

2.1

2.5

3.0

3.6

4.2

4.8

5.2

5.4

5.3

5.0

4.4

3.7

3.1

2.5

1.9

1.6

1.3

3.9

4.2

4.6

4.7

4.6

4.2

3.6

3.0

2.6

2.2

1.9

1.7

1.6

1.5

1.5

1.5

1.6

1.7

1.9

2.1

2.3

2.6

3.0

3.2

3.3

3.3

3.0

2.7

2.3

2.0

1.7

1.4

1.2

1.0

2.5

2.7

2.9

3.0

3.0

2.8

2.4

2.2

1.9

1.7

1.5

1.4

1.4

1.3

1.3

1.2

1.2

1.2

1.3

1.3

1.4

1.4

1.5

1.6

1.7

1.6

1.5

1.4

1.2

1.1

1.0

0.9

0.8

0.7

1.8

2.0

2.0

2.1

2.0

2.0

1.9

1.8

1.6

1.4

1.3

1.2

1.2

1.1

1.0

1.0

1.0

0.9

0.9

0.8

0.8

0.8

0.7

0.7

0.8

0.7

0.7

0.6

0.6

0.6

0.6

0.6

2.0

2.0

2.2

2.8

2.3

2.8

1.9

1.8

1.7

1.6

1.4

1.3

1.2

1.1

1.0

0.9

0.8

0.7

0.6

0.6

E1

E2

E1

E1

E2

E1

H

HHH

W1

W1

W1W1

W1

W1W1W2

W1

H H

W2

E1

W2

W1

Plan View Scale 1" = 25'

Scale

Drawing No.

A

Y T

O N

A B

E A

C

T M

O D

E R

N

IZ

A T

IO

N

E X

T E

R

IO

R L

IG

H

T

IN

G C

A L

C S

3.9

4.5

3.9

3.8

3.8

2.8

2.7

2.9

2.9

2.9

2.8

2.4

2.4

3.3

3.0

3.0

2.9

2.0

2.0

2.2

2.0

1.7

1.5

1.2

1.1

1.0

0.8

0.7

6.5

6.4

6.3

5.9

5.2

4.0

3.8

4.5

5.6

5.8

4.0

3.1

3.0

4.0

4.6

4.5

3.8

2.6

2.5

3.4

4.8

5.1

3.1

2.1

2.0

2.8

2.8

2.4

1.9

1.4

1.1

0.9

0.8

4.8

5.0

5.3

5.6

5.2

4.5

4.1

4.4

7.9

7.5

4.2

4.0

4.5

5.3

6.0

6.0

5.4

4.3

3.7

3.7

7.0

6.6

3.3

3.1

3.2

3.8

3.7

3.0

2.4

1.8

1.4

1.1

0.9

0.7

3.6

4.1

4.8

5.4

5.8

6.2

6.9

7.1

7.5

7.6

7.4

7.4

6.9

7.0

7.1

7.0

6.7

6.6

7.1

7.0

6.8

6.6

6.6

6.2

5.2

4.8

4.2

3.6

2.9

2.3

1.8

1.4

1.1

0.9

2.7

3.3

4.0

4.9

5.6

6.2

7.1

6.8

6.3

6.3

7.3

7.7

7.1

7.0

6.9

6.9

6.9

6.9

7.4

6.8

6.0

5.7

6.3

6.6

5.7

5.2

4.4

3.5

2.8

2.3

2.0

1.7

1.3

1.1

2.4

3.0

3.8

4.8

5.7

6.6

7.4

7.5

7.6

7.7

7.9

8.0

7.5

7.1

6.8

6.8

7.0

7.3

7.8

7.6

7.4

7.3

7.2

7.1

6.4

5.5

4.5

3.7

2.9

2.5

2.1

1.8

1.5

1.2

2.4

2.9

3.7

4.5

5.6

6.7

7.8

8.3

8.6

8.7

8.7

8.4

7.5

6.8

6.4

6.4

6.7

7.3

8.1

8.3

8.5

8.4

8.1

7.6

6.5

5.4