668-24-103 HAZ B31.pdf
PDF 9 MB Posted
- Solicitation number
- 36C26026Q0507
About this file
This document is a "Good Faith" asbestos investigation report for the Mann-Grandstaff Veterans Administration (VA) Medical Center roofing project, specifically focused on Building 31 located at 4815 North Assembly Street in Spokane, Washington. The survey was conducted on April 24, 2025, by Med-Tox Northwest (MTNW) under contract with MA Architects for VA Project Number 668-24-103.
The survey identified and sampled two roof sections in Building 31: new white membrane roofing over insulation board on metal pan decking, and old white membrane roofing over insulation board on metal pan decking. Five bulk samples were collected from four homogeneous materials and analyzed by Seattle Asbestos Test, LLC using Polarized Light Microscopy (PLM) dispersion staining per EPA Method 600/R-93/116. All samples tested negative for asbestos content. Table 1 confirms that no materials with greater than 1% asbestos were identified. Table 2 lists the non-asbestos-containing suspect materials, including vapor barriers with insulation on metal pan decking and white membrane roofing. Lead-containing paint analysis found no painted components that would be impacted by the project. The survey was conducted by AHERA-certified building inspectors employed by MTNW to comply with Washington Administrative Code 296-62-07721, 29 CFR, and Spokane Regional Clean Air Agency requirements. The report recommends that copies be provided to contractors performing work and remain on-site throughout the project duration per DOSH, OSHA, and SRCAA requirements. The document includes supporting laboratory certifications, analytical reports, and inspector credentials confirming professional qualifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Draft SOW.docx | DOCX document | |
| Sources Sought Past Performance Project Data Form.docx | DOCX document | |
| 668-24-103 HAZ B3.pdf | ||
| Draft Specifications.pdf | ||
| 668-24-103 HAZ B2.pdf | ||
| 668-24-103 HAZ B1.pdf | ||
| Sources Sought Contractor Information Form.docx | DOCX document | |
| 36C26026Q0507.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Post Office Box 1446 • Auburn, Washington 98071-1446 • PHONE (253) 351-0677 • E-mail: fullertona@medtoxnw.com Website: www.medtoxnw.com
NS:\MTNW\ALLJOBS\9000-9999\9243\REPORT\Mann-Grandstaff Roof Project Letter Building 31 MTNW 9243.1 -.doc
May 12, 2025
Sofie O’Brien MA Architects, Inc.
385 Van Ness Avenue, Suite 110 Torrance, California 90501
Subject: Mann-Grandstaff Veterans Administration (VA) Roofing Project “Good Faith” Asbestos Investigation- Building 31
4815 North Assembly Street, Spokane, Washington Med-Tox Northwest Project No. 9139.1
Dear Ms. O’Brien, On April 24, 2025, Anthony Fullerton of Med-Tox Northwest (MTNW) visited the Mann- Grandstaff VA Medical Center located at 4815 North Assembly Street in Spokane, Washington to conduct asbestos sampling of the roof systems. This survey was completed as part of the Mann- Grandstaff VA Roofing Project under a contract with MA Architects for VA Project Number 668-24-103. MTNW was contracted to survey several buildings as part of this project (Building 1, Building 2, Building 3 and Building 31). This report focuses on the results of the sampling conducted at Building 2. The remaining buildings will be submitted in separate reports.
Building 2 is a support building. This building has two different construction dates, so the roof sections were sampled independently of one another. On the day of the survey, Devin Dalcher, the COR for the VA escorted Mr. Fullerton to each of the areas to be sampled.
The following roof sections were identified and sampled at Building 31:
• Building 31, new-white membrane roofing over insulation board on metal pan decking.
• Building 31, old- white membrane roofing over insulation board on metal pan decking.
MTNW sampled each section independent from one another. Core samples from each of the roof sections along with a sealant. MTNW collected the cores for the project and then patched the sample location and painted an orange circle around the repair for easy identification of the sample location.
Mann-Grandstaff VA Roofing Project- Building 31 May 12, 2025 Med-Tox Northwest Project No. 9243.1
S:\MTNW\ALLJOBS\9000-9999\9243\REPORT\Mann-Grandstaff Roof Project Letter Building 31 MTNW 9243.1 -.doc
Asbestos Bulk Sampling Summary
There were five (5) samples collected from four (4) homogeneous materials (HM) identified during the survey. The core samples collected from both roof sections were determined to be negative for asbestos.
Samples were collected from the white rubber membrane roofing and off-white roof top unit (RTU) curb flashing sealant. Both were determined to be negative for asbestos.
For a complete list of all samples collected, please refer to the attached Summary of Materials Sampled for Asbestos as they pertain to Building 31.
The purpose of the survey was to provide a “Good Faith Survey” (per Washington Administrative Code (WAC) 296-62-07721, (1)(c)(ii)) and to identify the materials stated above which may require removal and/or special handling before any demolition activities.
As required by 29 Code of Federal Regulations (CFR), WAC 296-62-077 and Spokane Regional Clean Air Agency (SRCAA), building inspectors certified under the Asbestos Hazard Emergency Response Act (AHERA) and employed by MTNW conducted the survey.
Med-Tox Northwest employs inspectors certified by an Environmental Protection Agency (EPA)-approved training provider to provide Asbestos Hazard Emergency Response Act (AHERA) building surveys, including renovation and demolition surveys. A copy of Mr.
Fullerton’s certificate is attached.
Table 1 provides a complete list of suspect materials determined greater than 1% asbestos as they pertain to Building 31.
Table 1. Summary of Asbestos-Containing Materials.
Material Location Friable Quantity
Building 31
There were no materials with greater than 1% asbestos identified.
Note: This table is not to be used without the complete survey document including appendices for additional information.
Table 2 lists all suspect materials sampled that have been determined to be non-asbestos containing.
Table 2. Summary of Suspect Materials Determined Non-Asbestos Containing
Material Description
Building 31, new roof
Vapor barrier with insulation on metal pan decking (HM-18)
Building 31, new roof
Vapor barrier with insulation on metal pan decking (HM-18)
Building 31, throughout
May 12, 2025
S:\MTNW\ALLJOBS\9000-9999\9243\REPORT\Mann-Grandstaff Roof Project Letter Building 31 MTNW 9243.1 -.doc
Material Description
White membrane roofing (HM-17)
Off-white RTU curb flashing sealant (HM-20) Note: This table is not to be used without the complete survey document including appendices for additional information
Lead Containing Paint Summary
Lead was commonly used in most paint products until 1978, when it was banned from residential paints at concentrations greater than 600 parts per million (ppm); however, commercial applications with lead were still utilized and are still available. Lead is poisonous to the human body and presents a potential health hazard during any kind of disturbance (such as maintenance, including grinding, welding, and cutting) and if improperly disposed, where lead can enter drinking water supplies.
EPA defines lead-containing paint (LCP) as a concentration of 1.0 milligrams per centimeter squared (mg/cm2) or greater by X-Ray fluorescence (XRF) or 0.5 percent by weight (% wt.) or greater by total lead analysis; equivalent to 5,000 milligrams per kilogram (mg/kg). This EPA action level triggers requirements for protection of the environment, maintenance workers, and building occupants in child occupied facilities as defined by 40 CFR 745. Additionally, building components exceeding EPA lead levels may cause demolition waste streams to fail waste designation sampling performed for compliance with
WAC 173-303.
Occupational Safety and Health Administration (OSHA) and Washington Department of Occupational Safety and Health (DOSH) worker protection regulations have not defined a minimum concentration for regulating lead and has clarified that lead at any detectable concentration shall be considered regulated by 29 CFR 1926.62/WAC 296-155-176, Lead.
Paint sample results can be expressed in mg/kg (same as ppm), % wt. or mg/cm2 by area depending on the type of analytical methods used. Any positive result, regardless of the reporting method by the laboratory, will require compliance with 29 CFR 1926.62/WAC 296- 155-176.
Lead in Painted Surfaces
There were no painted components observed that will be impacted by the project.
Summary of Analysis
Asbestos-Containing Materials
A total of five (5) bulk samples were analyzed by Polarized Light Microscopy (PLM) dispersion staining EPA Method 600/R-93/116 by Seattle Asbestos Test, LLC. (SAT). SAT is accredited through the National Voluntary Laboratory Accreditation Program (NVLAP) administered by the National Institute of Standards and Technology (NIST), a division of the U.S. Department of Commerce. This accreditation does not constitute endorsement, May 12, 2025
S:\MTNW\ALLJOBS\9000-9999\9243\REPORT\Mann-Grandstaff Roof Project Letter Building 31 MTNW 9243.1 -.doc but rather a finding of laboratory competence. The NVLAP participant number for SAT is 200768-0 (certification copies and analytical results are attached.
Comments and Recommendations
Asbestos-Containing Materials
There were no asbestos containing materials identified.
We recommend that this survey report be placed on-site during renovation and/or selective demolition and copies provided to the contractor(s) bidding and performing work. DOSH, OSHA and SRCAA require that the report be on-site and available for review during the entire project duration.
1. The roof sections were sampled independently from one another. If additional materials are observed during the course of the project, they should be sampled by an AHERA inspector and analyzed by an accredited NVLAP laboratory.
This survey is not intended for use as abatement plans and/or specifications.
If you have any questions or require additional information, please call me at (253) 351- 0677.
Sincerely, Anthony Fullerton Senior Project Manager
Enclosures
Hazardous Building Materials Survey— Renovation Specific Mann-Grandstaff VA Roofing Project Building 31
May 2025 C-1 MA Architects
Table C-1. Summary of Materials Sampled for Asbestos
Sample Material Location AHERA Type HM Result Building 31 9243.1-31-031 White membrane roofing B31 Misc. 17 ND 9243.1-31-032 Vapor barrier with insulation on metal pan decking B31- new Misc. 18 ND
9243.1-31-033 Vapor barrier with insulation on metal pan decking
B31- old Misc. 19 ND
9243.1-31-034 Off-white RTU curb flashing sealant B31 Misc. 20 ND 9243.1-31-035 Off-white RTU curb flashing sealant B31 Misc. 20 ND HM = homogeneous material, Misc. = Miscellaneous, ND = None detect, PC = Point Count, RTU = roof top unit.
Mann-Grandstaff VA Roofing Project “Good Faith” Asbestos Investigation- Building 31
Photo 1: Building 31 old roof. There were no asbestos containing materials identified.
Photo 2: Building 31 new roof. There were no asbestos containing materials identified.
Project Name:
Customer PO:
EMSL Sales Rep:
Reported:
Med-Tox Northwest [MEDT50]
PO Box 1446
Auburn, WA 98071
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Anthony FullertonAttention:
(253) 351-0677 fullertona@medtoxnw.com Received: 04/30/2025 09:32
05/07/2025 15:06
Natalie Murphy
EMSL Order ID: 162554949
LIMS Reference ID: CD54949
EMSL Customer ID: MEDT50
9243.1
Analytical Results
Analyte Results RL Q DF Analysis Date
& AnalystWeight(g) Prep Date
& Tech
Analytical
MethodPrep Method
Client Sample ID: 92432.1-AF-01Pb/BUILDING 1, ROOF LEVEL 298, WALL, EIFS, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-01
1Lead 05/02/25 ET 05/02/25 CG<0.0092 % wt 0.0092 % wt SW-846 3050B SW 846-7000B0.1735
Sample Comments:
Client Sample ID: 92432.1-AF-02Pb/BUILDING 1, ROOF LEVEL 298, WALL, CONCRETE, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-02
1Lead 05/02/25 ET 05/02/25 CG<0.0066 % wt 0.0066 % wt SW-846 3050B SW 846-7000B0.2423
Sample Comments:
Client Sample ID: 92432.1-AF-03Pb/BUILDING 1, ROOF LEVEL 299, WALL, CONCRETE, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-03
1Lead 05/02/25 ET 05/02/25 CG<0.0064 % wt 0.0064 % wt SW-846 3050B SW 846-7000B0.2581
Sample Comments:
Client Sample ID: 92432.1-AF-04Pb/BUILDING 2, WALL, CONCRETE, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-04
1Lead 05/02/25 ET 05/02/25 CG<0.015 % wt 0.015 % wt SW-846 3050B SW 846-7000B0.106
Sample Comments:
Client Sample ID: 92432.1-AF-05Pb/BUILDING 3, WALL, CONCRETE, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-05
1Lead 05/02/25 ET 05/02/25 CG<0.0064 % wt 0.0064 % wt SW-846 3050B SW 846-7000B0.2597
Sample Comments:
[TOC_1]Sample Results[TOC]
EMSL Sales Rep:
Reported:
Med-Tox Northwest [MEDT50]
PO Box 1446
Auburn, WA 98071
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Anthony FullertonAttention:
(253) 351-0677 fullertona@medtoxnw.com Received: 04/30/2025 09:32
05/07/2025 15:06
Natalie Murphy
EMSL Order ID: 162554949
LIMS Reference ID: CD54949
EMSL Customer ID: MEDT50
9243.1
CertificationsAnalyte
Certified Analyses included in this Report
SW 846-7000B in Chips
16-OHDOH,16-AIHA ELLAPLead
[TOC_1]Certified
Analyses[TOC]
List of Certifications
Code Description Number Expires
16-MO 10180Missouri Drinking Water 03/31/2026
16-NYDOH 12130New York Potable Water, Metals Solid and Hazardous Waste - Asbestos 04/01/2026
16-AIHA ELLAP 157245American Industrial Hygiene Association (AIHA LAP, LLC) - ELLAP 06/01/2025
16-AIHA IHLAP 157245American Industrial Hygiene Association (AIHA LAP, LLC) - IHLAP 06/01/2025
16-CA ELAP 2575California Metals in DW, Chemistry and Bulk Asbestos in Hazardous Waste 06/30/2025
16-A2LA Food 2845.11A2LA Food Microbiology 01/31/2026
16-A2LA Chemistry 2845.25A2LA Environmental and Chemistry 11/30/2025
16-IN Metals/Asbestos C-49-09Indiana Lead and Metals and Asbestos in Drinking Water 12/31/2026
16-OHDOH E10040Ohio - Lead in Paint Chips, Wipes, Soil and Air 05/03/2026
16-FLDOH E871170Florida Asbestos and Metals in Drinking Water, PCBs 06/30/2025
16-NJDEP IN002New Jersey Metals, Organics and Inorganics in DW PCBs 06/30/2025
16-IN Colilert/HPC M-49-06Indiana Colilert and HPC 12/31/2026
Please see the specific Field of Testing (FOT) on www.emsl.com <http://www.emsl.com> for a complete listing of parameters for which EMSL is certified.
[TOC_1]Certifications[TOC]
Notes and Definitions
Item Definition
(Dig) For metals analysis, sample was digested.
[2C] Reported from the second channel in dual column analysis.
DA Direct Analysis
DF Dilution Factor
MDL Method Detection Limit.
ND Analyte was NOT DETECTED at or above the detection limit.
NR Spike/Surrogate showed no recovery.
Q Qualifier
RCS Respirable Crystalline Silica
RL Reporting Limit
Wet Sample is not dry weight corrected.
Measurement of uncertainty and any applicable definitions of method modifications are available upon request. Per EPA NLLAP policy, sample results are not blank corrected.
[TOC_1]Qualifiers, Definitions and Disclaimer[TOC]
EMSL Sales Rep:
Reported:
Med-Tox Northwest [MEDT50]
PO Box 1446
Auburn, WA 98071
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Anthony FullertonAttention:
(253) 351-0677 fullertona@medtoxnw.com Received: 04/30/2025 09:32
05/07/2025 15:06
Natalie Murphy
EMSL Order ID: 162554949
LIMS Reference ID: CD54949
EMSL Customer ID: MEDT50
9243.1
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. QC sample results are within quality control criteria and met method specifications unless otherwise noted. All results for soil samples are reported on a dry weight basis, unless otherwise noted.
Aleks Kuchenbrod Laboratory Manager or other approved signatory
Analysis following EMSL SOP for the Determination of Environmental Lead by FLAA. The laboratory has a reporting limit of 0.0064% by wt., based upon a minimum sample weight of
0.25g submitted to the lab, and is not responsible for any result or reporting limit provided in mg/cm2 since it is dependent upon an area value provided by non-lab personnel. A "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty and definitions of modifications are available upon request. Results in this report are not blank corrected unless specified.
Anthony L. Fullerton
AHERA Building Inspector
This is to certify that
4 hours of online refresher training as an
TSCA Title II, 40 CFR 763 (AHERA) to comply with the training requirements of has satisfactorily completed
194704 Certificate Number
Instructor:
EPA Provider # 1085
Aug 29, 2024 Date(s) of Training
Expires in 1 year.
N/AExam Score:
(if applicable)
Tracy Bockla
TERRACON TRAINING - FORMERLY ARGUS PACIFIC / 21905 64TH AVE W, SUITE 100 / MOUNTLAKE TERRACE, WASHINGTON 98043 / 206.285.3373 / EHS-TRAINING-TERRACON.COM
Certificate of Completion
STATE OF WASHINGTON
Department of Commerce
Lead-Based Paint Activities Program
Has fulfilled the certification requirements of
WAC 365-230
and has been certified to conduct lead based paint activities as a
Risk Assessor.
Certification # Issuance Date Expiration Date 0242 06/21/2023 04/03/2026
Anthony L Fullerton
| Mann-Grandstaff Roof Project Letter Building 31 MTNW 9243.1 - |
| AsbestosTable_9243.1 Building 31 |
| 9243.1 Buiding 31 photolog |
| Scan2025-05-16_092600 |
| 202509607 |
| 162554949_002 |
| 162554949_coc |
| Anthony Fullerton RA Certificate |
| Fullerton_CERT_140242 |
| SAT NVLAP CERT 10012024- 09302025 Lynnwood |
File details come from the government source that posted it. Updated .