668-24-103 HAZ B1.pdf
PDF 10 MB Posted
- Solicitation number
- 36C26026Q0507
About this file
This is a "Good Faith" asbestos investigation report for the Mann-Grandstaff Veterans Administration (VA) Medical Center in Spokane, Washington, conducted by Med-Tox Northwest (MTNW) on April 24, 2025, as part of VA Project Number 668-24-103 under contract with MA Architects.
The survey identified asbestos-containing materials in Building 1, the main hospital structure, which has multiple roof levels. MTNW collected thirty bulk samples from sixteen homogeneous materials across five roof sections (B397, B399, B398, B298, and B299). All core samples from the roof levels were determined to contain 2% Chrysotile asbestos. Specifically, the survey identified asbestos in built-up roofing with gravel ballast across all five roof sections, totaling 4,986 square feet of asbestos-containing material categorized as non-friable. Samples from parapet flashing sealants, silver coat paints, vent sealants, and concrete spalling debris tested negative for asbestos. Three paint chip samples were also analyzed for lead content on exterior surfaces at roof levels B298 and B299, all returning results below reporting limits. The survey was conducted by Anthony Fullerton, a certified AHERA building inspector employed by MTNW, and samples were analyzed by Seattle Asbestos Test, LLC (accredited through NVLAP, participant number 200768-0) using Polarized Light Microscopy. The report recommends that all identified asbestos materials in Table 1 be removed prior to renovation or demolition in compliance with 29 CFR, WAC 296-62-077, and Spokane Regional Clean Air Agency requirements. The report notes that separate survey results for Buildings 2, 3, and 31 will be submitted in subsequent reports.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 668-24-103 HAZ B31.pdf | ||
| Draft SOW.docx | DOCX document | |
| Sources Sought Past Performance Project Data Form.docx | DOCX document | |
| 668-24-103 HAZ B3.pdf | ||
| Draft Specifications.pdf | ||
| 668-24-103 HAZ B2.pdf | ||
| Sources Sought Contractor Information Form.docx | DOCX document | |
| 36C26026Q0507.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Post Office Box 1446 • Auburn, Washington 98071-1446 • PHONE (253) 351-0677 • E-mail: fullertona@medtoxnw.com Website: www.medtoxnw.com
NC:\Users\Anthony Fullerton\Desktop\Work folder\MA Architects\Hospital\Mann-Grandstaff Roof Project Letter Building 1 MTNW
9243.1 -.doc
May 8, 2025
Sofie O’Brien MA Architects, Inc.
385 Van Ness Avenue, Suite 110 Torrance, California 90501
Subject: Mann-Grandstaff Veterans Administration (VA) Roofing Project “Good Faith” Asbestos Investigation- Building 1
4815 North Assembly Street, Spokane, Washington Med-Tox Northwest Project No. 9139.1
Dear Ms. O’Brien, On April 24, 2025, Anthony Fullerton of Med-Tox Northwest (MTNW) visited the Mann- Grandstaff VA Medical Center located at 4815 North Assembly Street in Spokane, Washington to conduct asbestos sampling of the roof systems. This survey was completed as part of the Mann- Grandstaff VA Roofing Project under a contract with MA Architects for VA Project Number 668-24-103. MTNW was contracted to survey several buildings as part of this project (Building 1, Building 2, Building 3 and Building 31). This report focuses on the results of the sampling conducted at Building 1. The remaining buildings will be submitted in separate reports.
Building 1 is the main hospital on the campus. This building has multiple different roof levels. The roofs to be surveyed were identified by the client. On the day of the survey, Devin Dalcher, the COR for the VA escorted Mr. Fullerton to each of the areas to be sampled.
The VA has unique identifying numbers assigned to each roof. MTNW utilized these roof identifiers in the sample prefix to ease in keeping the data for each roof readily identifiable.
There are several different roof systems that will be impacted by the planned project. The following roof sections were identified and sampled at Building 1:
• Roof B397- white membrane roofing over gypsum board layer, insulation board and built-up roofing with gravel ballast on concrete decking. At area sampled, roofing is approximately 3.5” to 4.5” thick.
• Roof B399- black membrane roofing with black sealant over foam insulating layer and built-up roofing with gravel ballast on concrete decking. At area sampled, roofing is approximately 6” to 7” thick.
S_OBrien Rectangle
Mann-Grandstaff VA Roofing Project- Building 1 May 8, 2025 Med-Tox Northwest Project No. 9243.1
C:\Users\Anthony Fullerton\Desktop\Work folder\MA Architects\Hospital\Mann-Grandstaff Roof Project Letter Building 1 MTNW
• Roof B398- white membrane roofing with tan sealant over gypsum board layer, insulation board and built-up roofing with gravel ballast on concrete decking. At area sampled, roofing is approximately 3.5” to 4.5” thick.
• Roof B298- white membrane roofing over insulation board and built-up roofing on concrete decking. At area sampled, roofing is approximately 4” to 5” thick.
• Roof B299- white membrane roofing over insulation board and built-up roofing on concrete decking. At area sampled, roofing is approximately 4” to 5” thick. There were two core samples collected from this roof. One on the south end by the drain (HM-12) and the other at the north end of the roof (HM-13).
MTNW sampled each section independent from one another. Core samples from each of the roof sections along with various sealants. MTNW collected the cores for the project and then patched the sample location and painted an orange circle around the repair for easy identification of the sample location.
Asbestos Bulk Sampling Summary
There were thirty (30) samples collected from sixteen (16) homogeneous materials (HM) identified during the survey. The core samples collected from each of the roof levels (B397, B399, B398, B298, and B299) were all determined to be asbestos containing (2% Chrysotile asbestos). There were two roof core samples collected from roof B299 (HM-12 and HM-13). Sample 9243.1-299-021 was determined to contain 2% Chrysotile asbestos in the roof core and sample 9243.1-299-022 was determined to negative for the presence of asbestos. For reporting purposes, the B299 roof is considered asbestos containing. Roof levels B397 and B398 have multiple layers identified to contain asbestos.
Samples collected from the various parapet flashing sealants silver coat paints, vent sealants and concrete spalling debris were determined to be negative for asbestos.
For a complete list of all samples collected, please refer to the attached Summary of Materials Sampled for Asbestos as they pertain to Building 1.
The purpose of the survey was to provide a “Good Faith Survey” (per Washington Administrative Code (WAC) 296-62-07721, (1)(c)(ii)) and to identify the materials stated above which may require removal and/or special handling before any demolition activities.
As required by 29 Code of Federal Regulations (CFR), WAC 296-62-077 and Spokane Regional Clean Air Agency (SRCAA), building inspectors certified under the Asbestos Hazard Emergency Response Act (AHERA) and employed by MTNW conducted the survey.
Med-Tox Northwest employs inspectors certified by an Environmental Protection Agency (EPA)-approved training provider to provide Asbestos Hazard Emergency Response Act (AHERA) building surveys, including renovation and demolition surveys. A copy of Mr.
Fullerton’s certificate is attached.
May 8, 2025
C:\Users\Anthony Fullerton\Desktop\Work folder\MA Architects\Hospital\Mann-Grandstaff Roof Project Letter Building 1 MTNW
Table 1 provides a complete list of suspect materials determined greater than 1% asbestos as they pertain to Building 1.
Table 1. Summary of Asbestos-Containing Materials.
Material Location Friable Quantity Building 1, Roof B397 Built-up roofing with gravel ballast (HM-03) B397 No 290 SF Building 1, Roof B399 Built-up roofing with gravel ballast (HM-06) B399 No 400 SF Building 1, Roof B398 built-up roofing with gravel ballast (HM-07) B397 No 290 SF Building 1, Roof B298
Built-up roofing (HM-09) B298 No 1,290 SF
Building 1, Roof B299 Built-up roofing with gravel ballast under white membrane roofing (HM-12 and HM-13*)
B299 No 2,716 SF
SF = square feet. Note: This table is not to be used without the complete survey document including appendices for additional information. * HM-13 was determined to be negative for asbestos but due to the one overlaying roof system, this material is positive for reporting purposes.
Table 2 lists all suspect materials sampled that have been determined to be non-asbestos containing.
Table 2. Summary of Suspect Materials Determined Non-Asbestos Containing
Material Description Material Description Building 1, Roof B397 White membrane roofing (HM-01) Gypsum board under HM-01 (HM-02) Tan/gray parapet flashing sealant (HM-04) Building 1, Roof B399 Black membrane roofing and sealant (HM-05) Tan/gray parapet flashing sealant
(HM-04)
Building 1, Roof B398 White membrane roofing (HM-01) Tan/gray parapet flashing sealant (HM-
04) Building 1, Roof B298 White membrane roofing (HM-01) Brown insulation board under HM-01
(HM-08)
May 8, 2025
C:\Users\Anthony Fullerton\Desktop\Work folder\MA Architects\Hospital\Mann-Grandstaff Roof Project Letter Building 1 MTNW
Material Description Material Description Black with white parapet flashing sealant (HM- 10)
White membrane roof sealant (HM-11)
Building 1, Roof B299 Tan/gray parapet flashing caulk Silver coat paint on vents (HM-14) Black vent sealant (HM-15) Concrete spalling debris (HM-16) Note: This table is not to be used without the complete survey document including appendices for additional information.
Lead Containing Paint Summary
Lead was commonly used in most paint products until 1978, when it was banned from residential paints at concentrations greater than 600 parts per million (ppm); however, commercial applications with lead were still utilized and are still available. Lead is poisonous to the human body and presents a potential health hazard during any kind of disturbance (such as maintenance, including grinding, welding, and cutting) and if improperly disposed, where lead can enter drinking water supplies.
EPA defines lead-containing paint (LCP) as a concentration of 1.0 milligrams per centimeter squared (mg/cm2) or greater by X-Ray fluorescence (XRF) or 0.5 percent by weight (% wt.) or greater by total lead analysis; equivalent to 5,000 milligrams per kilogram (mg/kg). This EPA action level triggers requirements for protection of the environment, maintenance workers, and building occupants in child occupied facilities as defined by 40 CFR 745. Additionally, building components exceeding EPA lead levels may cause demolition waste streams to fail waste designation sampling performed for compliance with
WAC 173-303.
Occupational Safety and Health Administration (OSHA) and Washington Department of Occupational Safety and Health (DOSH) worker protection regulations have not defined a minimum concentration for regulating lead and has clarified that lead at any detectable concentration shall be considered regulated by 29 CFR 1926.62/WAC 296-155-176, Lead.
Paint sample results can be expressed in mg/kg (same as ppm), % wt. or mg/cm2 by area depending on the type of analytical methods used. Any positive result, regardless of the reporting method by the laboratory, will require compliance with 29 CFR 1926.62/WAC 296- 155-176.
Lead in Painted Surfaces During the MTNW survey exterior painted surfaces that may potentially be impacted were tested for lead using bulk sample collection and chemical analysis. Three paint chip samples were collected. Analytical results are provided in Table 3.
May 8, 2025
C:\Users\Anthony Fullerton\Desktop\Work folder\MA Architects\Hospital\Mann-Grandstaff Roof Project Letter Building 1 MTNW
Table 3. Summary of Materials Sampled For Lead
Sample Number Location Component Substrate Color Result (% by wt.)
Building 1 9243.1-AF-01Pb Building 1, roof level
B298 Wall EIFS Tan <0.0092
9243.1-AF-02Pb Building 1, roof level B298
Wall Concrete Tan <0.0066
9243.1-AF-03Pb Building 1, roof level B299
Wall Concrete Tan <0.0064
The Washington Department of Occupational Safety and Health (DOSH) worker protection regulations have stated that lead at any detectable concentration shall be considered regulated (Washington Administrative Code [WAC] 296-155-176, Lead.
Summary of Analysis
Asbestos-Containing Materials
A total of thirty (30) bulk samples were analyzed by Polarized Light Microscopy (PLM) dispersion staining EPA Method 600/R-93/116 by Seattle Asbestos Test, LLC. (SAT). SAT is accredited through the National Voluntary Laboratory Accreditation Program (NVLAP) administered by the National Institute of Standards and Technology (NIST), a division of the U.S. Department of Commerce. This accreditation does not constitute endorsement, but rather a finding of laboratory competence. The NVLAP participant number for SAT is 200768-0 (certification copies and analytical results are attached.
Lead-Based Paint
Bulk paint chip samples were submitted to EMSL Analytical, Inc. (EMSL), for analysis. A total of three (3) paint chip samples were analyzed for lead using atomic absorption spectroscopy (AAS) to determine the presence and percentage of lead. Procedures for analyzing metals are found in the ASTM International D-3335-78 and EPA Method Manual SW-846, Method 6010. (EMSL used SW 846 3050B*/7000B) an equivalent analytical method.
Analytical results for paint chip samples and EMSL Analytical, Inc., laboratory certification are attached.
Comments and Recommendations
Asbestos-Containing Materials Med-Tox Northwest recommends, and state law requires, that all asbestos materials identified in Table 1 be removed prior to renovation or demolition.
May 8, 2025
C:\Users\Anthony Fullerton\Desktop\Work folder\MA Architects\Hospital\Mann-Grandstaff Roof Project Letter Building 1 MTNW
We recommend that this survey report be placed on-site during renovation and/or selective demolition and copies provided to the contractor(s) bidding and performing work. DOSH, OSHA and SRCAA require that the report be on-site and available for review during the entire project duration.
1. The roof sections were sampled independently from one another. If additional materials are observed during the course of the project, they should be sampled by an AHERA inspector and analyzed by an accredited NVLAP laboratory.
This survey is not intended for use as abatement plans and/or specifications.
If you have any questions or require additional information, please call me at (253) 351- 0677.
Sincerely, Anthony Fullerton Senior Project Manager
Enclosures
Hazardous Building Materials Survey— Renovation Specific
Mann-Grandstaff VA Roofing Project - Building 1
May 2025 C-1 MA Architects
Table C-1. Summary of Materials Sampled for Asbestos
Sample Material Location AHERA
Type
HM Result
Building 1, Roof B397
9243.1-397-001 White membrane roofing B397 Misc. 01 ND
9243.1-397-002 Gypsum board under HM01 B397 Misc. 02 ND
9243.1-397-003 Built-up roofing B397 Misc. 03 Layer 1: 2% CHR
Layer 2: 2% CHR
9243.1-397-004 Tan/ gray parapet flashing caulk B397 Misc. 04 ND
9243.1-397-005 Tan/ gray parapet flashing caulk B397 Misc. 04 ND
Building 1, Roof 399
9243.1-399-006 Black membrane roofing and sealant
B399 Misc. 05 ND
9243.1-399-007 Built-up roofing B399 Misc. 06 2% CHR
9243.1-399-008 Tan/ gray parapet flashing caulk B399 Misc. 04 ND
9243.1-399-009 Tan/ gray parapet flashing caulk B399 Misc. 04 ND
Building 1, Roof 398
9243.1-398-010 White membrane roofing B398 Misc. 01 ND
9243.1-398-011 Gypsum board under HM01 B398 Misc. 02 ND
9243.1-398-012 Built-up roofing B398 Misc. 07 Layer 1: 2% CHR
Layer 2: 2% CHR
9243.1-398-013 Tan/ gray parapet flashing caulk B399 Misc. 04 ND
Building 1, Roof 298
9243.1-298-014 White membrane roofing B298 Misc. 01 ND
9243.1-298-015 Brown insulation board under
HM01
B298 Misc. 08 ND
9243.1-298-016 Built-up roofing B298 Misc. 09 2% CHR
9243.1-298-017 Black with tan parapet flashing sealant
B298 Misc. 10 ND
9243.1-298-018 Black with white parapet flashing sealant
B298 Misc. 10 ND
9243.1-298-019 White membrane roof sealant B298 Misc. 11 ND
9243.1-298-020 White membrane roof sealant B298 Misc. 11 ND
Building 1, Roof 299
9243.1-299-021 Built-up roofing with gravel ballast under white membrane roofing
B299- south end by drain
Misc. 12 2% CHR
9243.1-299-022 Built-up roofing with gravel ballast under white membrane roofing
B299- north Misc. 13 ND
9243.1-299-023 Tan/ gray parapet flashing caulk B299 Misc. 04 ND
9243.1-299-024 Silver coat paint on vent B299 TSI 14 ND
9243.1-299-025 Silver coat paint on vent B299 TSI 14 ND
Hazardous Building Materials Survey— Renovation Specific
Mann-Grandstaff VA Roofing Project - Building 1
May 2025 C-2 MA Architects
Sample Material Location AHERA
Type
HM Result
9243.1-299-026 Silver coat paint on vent B299 south end vent Panel P, BKR 8
TSI 14 ND
9243.1-299-027 Black vent sealant B299 south end vent Panel P, BKR 8
Misc. 15 ND
9243.1-299-028 Black vent sealant B299 south end vent Panel P, BKR 8
Misc. 15 ND
9243.1-299-029 Concrete spalling debris B299 Misc. 16 ND
9243.1-299-030 Concrete spalling debris B299 Misc. 16 ND
CHR = Chrysotile, HM = homogeneous material, Misc. = Miscellaneous, ND = None detect, TSI = Thermal System Insulation, Mann-Grandstaff VA Roofing Project
Photo 1: Building 1 B397 roof. The built-up roofing under the white membrane roof is asbestos containing.
Photo 2: Building 1 B399 roof. The built-up roofing under the black membrane
Photo 3: Building 1 B398 roof. The built-up roofing under the white membrane
Photo 4: Building 1 B298 roof. The built-up roofing under the white membrane
Photo 5: Building 1 B299 roof. The built-up roofing under the white membrane
Project Name:
Customer PO:
EMSL Sales Rep:
Reported:
Med-Tox Northwest [MEDT50]
PO Box 1446
Auburn, WA 98071
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Anthony FullertonAttention:
(253) 351-0677 fullertona@medtoxnw.com Received: 04/30/2025 09:32
05/07/2025 15:06
Natalie Murphy
EMSL Order ID: 162554949
LIMS Reference ID: CD54949
EMSL Customer ID: MEDT50
9243.1
Analytical Results
Analyte Results RL Q DF Analysis Date
& AnalystWeight(g) Prep Date
& Tech
Analytical
MethodPrep Method
Client Sample ID: 92432.1-AF-01Pb/BUILDING 1, ROOF LEVEL 298, WALL, EIFS, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-01
1Lead 05/02/25 ET 05/02/25 CG<0.0092 % wt 0.0092 % wt SW-846 3050B SW 846-7000B0.1735
Sample Comments:
Client Sample ID: 92432.1-AF-02Pb/BUILDING 1, ROOF LEVEL 298, WALL, CONCRETE, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-02
1Lead 05/02/25 ET 05/02/25 CG<0.0066 % wt 0.0066 % wt SW-846 3050B SW 846-7000B0.2423
Sample Comments:
Client Sample ID: 92432.1-AF-03Pb/BUILDING 1, ROOF LEVEL 299, WALL, CONCRETE, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-03
1Lead 05/02/25 ET 05/02/25 CG<0.0064 % wt 0.0064 % wt SW-846 3050B SW 846-7000B0.2581
Sample Comments:
Client Sample ID: 92432.1-AF-04Pb/BUILDING 2, WALL, CONCRETE, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-04
1Lead 05/02/25 ET 05/02/25 CG<0.015 % wt 0.015 % wt SW-846 3050B SW 846-7000B0.106
Sample Comments:
Client Sample ID: 92432.1-AF-05Pb/BUILDING 3, WALL, CONCRETE, TAN Date Sampled: 04/24/25
Matrix: Chips LIMS Reference ID: CD54949-05
1Lead 05/02/25 ET 05/02/25 CG<0.0064 % wt 0.0064 % wt SW-846 3050B SW 846-7000B0.2597
Sample Comments:
[TOC_1]Sample Results[TOC]
EMSL Sales Rep:
Reported:
Med-Tox Northwest [MEDT50]
PO Box 1446
Auburn, WA 98071
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Anthony FullertonAttention:
(253) 351-0677 fullertona@medtoxnw.com Received: 04/30/2025 09:32
05/07/2025 15:06
Natalie Murphy
EMSL Order ID: 162554949
LIMS Reference ID: CD54949
EMSL Customer ID: MEDT50
9243.1
CertificationsAnalyte
Certified Analyses included in this Report
SW 846-7000B in Chips
16-OHDOH,16-AIHA ELLAPLead
[TOC_1]Certified
Analyses[TOC]
List of Certifications
Code Description Number Expires
16-MO 10180Missouri Drinking Water 03/31/2026
16-NYDOH 12130New York Potable Water, Metals Solid and Hazardous Waste - Asbestos 04/01/2026
16-AIHA ELLAP 157245American Industrial Hygiene Association (AIHA LAP, LLC) - ELLAP 06/01/2025
16-AIHA IHLAP 157245American Industrial Hygiene Association (AIHA LAP, LLC) - IHLAP 06/01/2025
16-CA ELAP 2575California Metals in DW, Chemistry and Bulk Asbestos in Hazardous Waste 06/30/2025
16-A2LA Food 2845.11A2LA Food Microbiology 01/31/2026
16-A2LA Chemistry 2845.25A2LA Environmental and Chemistry 11/30/2025
16-IN Metals/Asbestos C-49-09Indiana Lead and Metals and Asbestos in Drinking Water 12/31/2026
16-OHDOH E10040Ohio - Lead in Paint Chips, Wipes, Soil and Air 05/03/2026
16-FLDOH E871170Florida Asbestos and Metals in Drinking Water, PCBs 06/30/2025
16-NJDEP IN002New Jersey Metals, Organics and Inorganics in DW PCBs 06/30/2025
16-IN Colilert/HPC M-49-06Indiana Colilert and HPC 12/31/2026
Please see the specific Field of Testing (FOT) on www.emsl.com <http://www.emsl.com> for a complete listing of parameters for which EMSL is certified.
[TOC_1]Certifications[TOC]
Notes and Definitions
Item Definition
(Dig) For metals analysis, sample was digested.
[2C] Reported from the second channel in dual column analysis.
DA Direct Analysis
DF Dilution Factor
MDL Method Detection Limit.
ND Analyte was NOT DETECTED at or above the detection limit.
NR Spike/Surrogate showed no recovery.
Q Qualifier
RCS Respirable Crystalline Silica
RL Reporting Limit
Wet Sample is not dry weight corrected.
Measurement of uncertainty and any applicable definitions of method modifications are available upon request. Per EPA NLLAP policy, sample results are not blank corrected.
[TOC_1]Qualifiers, Definitions and Disclaimer[TOC]
EMSL Sales Rep:
Reported:
Med-Tox Northwest [MEDT50]
PO Box 1446
Auburn, WA 98071
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047 www.emsl.com
Anthony FullertonAttention:
(253) 351-0677 fullertona@medtoxnw.com Received: 04/30/2025 09:32
05/07/2025 15:06
Natalie Murphy
EMSL Order ID: 162554949
LIMS Reference ID: CD54949
EMSL Customer ID: MEDT50
9243.1
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. QC sample results are within quality control criteria and met method specifications unless otherwise noted. All results for soil samples are reported on a dry weight basis, unless otherwise noted.
Aleks Kuchenbrod Laboratory Manager or other approved signatory
Analysis following EMSL SOP for the Determination of Environmental Lead by FLAA. The laboratory has a reporting limit of 0.0064% by wt., based upon a minimum sample weight of
0.25g submitted to the lab, and is not responsible for any result or reporting limit provided in mg/cm2 since it is dependent upon an area value provided by non-lab personnel. A "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty and definitions of modifications are available upon request. Results in this report are not blank corrected unless specified.
Anthony L. Fullerton
AHERA Building Inspector
This is to certify that
4 hours of online refresher training as an
TSCA Title II, 40 CFR 763 (AHERA) to comply with the training requirements of has satisfactorily completed
194704 Certificate Number
Instructor:
EPA Provider # 1085
Aug 29, 2024 Date(s) of Training
Expires in 1 year.
N/AExam Score:
(if applicable)
Tracy Bockla
TERRACON TRAINING - FORMERLY ARGUS PACIFIC / 21905 64TH AVE W, SUITE 100 / MOUNTLAKE TERRACE, WASHINGTON 98043 / 206.285.3373 / EHS-TRAINING-TERRACON.COM
Certificate of Completion
STATE OF WASHINGTON
Department of Commerce
Lead-Based Paint Activities Program
Has fulfilled the certification requirements of
WAC 365-230
and has been certified to conduct lead based paint activities as a
Risk Assessor.
Certification # Issuance Date Expiration Date 0242 06/21/2023 04/03/2026
Anthony L Fullerton
AIHA Laboratory Accreditation Programs, LLC acknowledges that
EMSL Analytical, Inc.
6340 Castleplace Drive Indianapolis, IN 46250
Laboratory ID: LAP-157245 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA LAP), LLC accreditation to the ISO/IEC 17025:2017 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE Accreditation Expires: June 01, 2025
ENVIRONMENTAL LEAD Accreditation Expires: June 01, 2025
ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: June 01, 2025
FOOD Accreditation Expires:
UNIQUE SCOPES Accreditation Expires:
Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2017 and AIHA LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.
Revision21: 05/15/2023
Cheryl O Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC
Date Issued: 06/01/2023
Effective: 05/15/2023 Revision: 9
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
EMSL Analytical, Inc. Laboratory ID: LAP-157245 6340 Castleplace Drive Indianapolis, IN 46250 Issue Date: 06/01/2023
The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory's current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.
The EPA recognizes the AIHA LAP, LLC ELLAP program as meeting the requirements of the National Lead Laboratory Accreditation Program (NLLAP) established under Title X of the Residential Lead-Based Paint Hazard Reduction Act of 1992 and includes paint, soil and dust wipe analysis. Air and composited wipes analyses are not included as part of the NLLAP.
Environmental Lead Laboratory Accreditation Program (ELLAP)
Initial Accreditation Date: 09/01/2002
Component, parameter or characteristic tested Technology sub-type/Detector Method Method Description
(for internal methods only)
Airborne Dust AA NIOSH 7082 N/A
EPA SW-846 3050B N/A
EPA SW-846 3051A N/AAA
EPA SW-846 7000B N/A
EPA SW-846 3050B N/A
EPA SW-846 3051A N/A
Paint
ICP
EPA SW-846 6010D N/A
EPA SW-846 3050B N/A
EPA SW-846 3051A N/AAA
EPA SW-846 7000B N/A
EPA SW-846 3050B N/A
EPA SW-846 3051A N/A
Settled Dust by Wipe
ICP
EPA SW-846 6010D N/A
EPA SW-846 3050B N/A
EPA SW-846 3051A N/ASoil AA
EPA SW-846 7000B N/A
Effective: 05/15/2023 Revision: 9
Component, parameter or characteristic tested Technology sub-type/Detector Method Method Description
(for internal methods only)
EPA SW-846 3050B N/A
EPA SW-846 3051A N/AICP
EPA SW-846 6010D N/A
A complete listing of currently accredited ELLAP laboratories is available on the AIHA LAP, LLC website at:
http://www.aihaaccreditedlabs.org
| Mann-Grandstaff Roof Project Letter Building 1 MTNW 9243.1 - |
| Asbestos Bulk Sampling Summary |
| Lead Containing Paint Summary |
| Lead in Painted Surfaces |
| Summary of Analysis |
| Asbestos-Containing Materials |
| Lead-Based Paint |
| Comments and Recommendations |
| Asbestos-Containing Materials |
| AsbestosTable_9243.1. - Building 1 |
| 9243.1 Buiding 1 photolog |
| Scan2025-05-16_091908 |
| 202509607 |
| 162554949_002 |
| 162554949_coc |
| Anthony Fullerton RA Certificate |
| Fullerton_CERT_140242 |
| SAT NVLAP CERT 10012024- 09302025 Lynnwood |
| AIHA ELLAP Indianapolis |
| lapaccred_cert_LAP-157245 |
| scopedocLAP-157245 ELLAP |
File details come from the government source that posted it. Updated .