646-21-101_UD SPS AHU RO Upgrade_251107.pdf
PDF 37 MB Posted
- Solicitation number
- 36C24426R0049
About this file
This file is a comprehensive set of architectural and construction drawings for a renovation project at the Pittsburgh Veterans Affairs Medical Center.
The project involves upgrading the University Drive Sterile Processing Services (SPS) Air Handling Unit (AHU) and Reverse Osmosis (RO) system at Pittsburgh VAMC, located at University Drive C, Pittsburgh, Pennsylvania 15240. The scope encompasses renovation of approximately 12,851 square feet of ground floor space within a fully sprinklered, four-story Type I-332 construction building. The work is organized into four construction phases designed to maintain operational continuity of the SPS and logistics functions. Phase 1 involves establishing temporary storage and staging areas in existing office spaces; Phase 2 converts the existing logistics area into the new SPS facility; Phase 3 converts the existing SPS area into the new logistics area; and Phase 4 restores temporary areas to usable spaces as directed by the VA. The construction includes comprehensive demolition, new partition installation with fire-rated walls, mechanical, plumbing, and electrical upgrades including reverse osmosis water treatment equipment, new ductwork and hydronic piping, interior finishes with new LVT flooring and acoustic ceiling tiles, fire protection modifications, and new life safety infrastructure. The drawings indicate an occupant load of 81 persons with required egress accommodating travel distances up to 300 feet in compliance with NFPA 101 Life Safety Code. Documentation includes detailed phasing plans, ICRA assessments confirming Levels 2 and 3 areas, equipment relocation schedules specifying storage shelving and cart movements, and extensive construction details for temporary and permanent partitions, door installations, and MEP system integration.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24426R0049 0001.docx | DOCX document | |
| P07 Wage Determination PA20260001 1.30.26.pdf | ||
| 00-Specifications.pdf | ||
| EXHIBIT D - Past Perfomance Questionnaire.docx | DOCX document | |
| EXHIBIT B - Subcontractor Consent and Reference Form.docx | DOCX document | |
| EXHIBIT A - Statement of Prior Experience.docx | DOCX document | |
| P03 Liquidated Damages Pittsburgh 36C24426R0049 646-21-101 UD SPS AHU RO Upgrade signed.pdf | ||
| 36C24426R0049_2.docx | DOCX document | |
| EXHIBIT C - Sample Transmittal Letter for Past Performance Evaluation Questionnaire.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet Number Sheet Name
General
GI-000 COVER SHEET
GI-002 GENERAL NOTES, SYMBOLS, ABBREVIATIONS, & CODE DATA
GI-003 ICRA ASSESSMENT
GI-101 LIFE SAFETY PLAN
GI-102 GROUND FLOOR PHASING PLAN - PHASE 1
GI-103 GROUND FLOOR PHASING PLAN - PHASE 2
GI-104 GROUND FLOOR PHASING PLAN - PHASE 3
GI-105 GROUND FLOOR PHASING PLAN - PHASE 4
GI-106 ENLARGED PHASING PLANS AREA 1 & 2 - PHASE 1
GI-107 ENLARGED PHASING PLANS AREA 1 & 3 - PHASE 1
GI-108 PHASING SCHEDULES & DETAILS
Structural
S-101 OVERALL GROUND FLOOR PLAN
Architectural
AE-513 ROOF DETAILS
AE-601 DOOR SCHEDULE, WALL TYPES, AND DETAILS
AE-701 OVERALL GROUND FLOOR - SIGNAGE PLAN
AE-702 SIGN DETAILS
Interior Design
IN-101 OVERALL GROUND FLOOR FINISH PLAN
IN-401 ENLARGED FINISH PLAN - A1
IN-402 ENLARGED FINISH PLAN - A2
IN-403 ENLARGED PLANS & ELEVATIONS
IN-404 SPS LOCKERS/SHOWER ROOM PLANS & ELEVATIONS
IN-405 ENLARGED LOGISTICS LOCKERS
IN-601 FINISH SCHEDULES AND DETAILS
Fire Protection
FPD-101 FIRE PROTECTION GROUND FLOOR - DEMO.
FP-101 FIRE PROTECTION GROUND FLOOR - NEW
Plumbing
AD-101 GROUND FLOOR DEMOLITION PLAN
AD-102 GROUND FLOOR DEMOLITION RCP
AD-103 ROOF PLAN (PARTIAL) - DEMOLITION
AE-100 OVERALL GROUND FLOOR PLAN - ROOM AREAS
AE-101 OVERALL GROUND FLOOR PLAN
AC-101 OVERALL GROUND FLOOR RCP
AE-102 ROOF PLAN (PARTIAL)
AE-211 BUILDING SECTIONS
AE-241 PLAN DETAILS
AE-261 ENLARGED DETAILS
AE-301 WALL TYPES
AE-401 ENLARGED GROUND FLOOR PLAN - A1
AE-402 ENLARGED GROUND FLOOR PLAN - A2
AC-401 ENLARGED GROUND FLOOR RCP - A1
AC-402 ENLARGED GROUND FLOOR RCP - A2
AE-411 ENLARGED EQUIPMENT LAYOUT PLAN
AE-412 EQUIPMENT ELEVATIONS
AE-511 ROOFING SYSTEM BASIS OF DESIGN
AE-512 ROOF DETAILS
P-500 PLUMBING DETAILS
P-501 PLUMBING DETAILS
P-600 PLUMBING SCHEDULES
Plumbing - Reverse Osmosis
PJ-201 REVERSE OSMOSIS
PJ-202 REVERSE OSMOSIS
Mechanical
M-000 MECHANICAL SYMBOLS AND ABBREVIATIONS
MD-10G.1.TLS1 GROUND LEVEL - MECHANICAL DEMOLITION - PHASE 1 - TEMPORARY LOGISTICS STORAGE #1
MD-10G.1.TLS2 GROUND LEVEL - MECHANICAL DEMOLITION - PHASE 1 - TEMPORARY LOGISTICS STORAGE #2
MD-10G.2.A2 GROUND LEVEL - MECHANICAL DEMOLITION - PHASE 2 - AREA A2 & LOADING DOCK AREA
MD-10G.3.A1 GROUND LEVEL - MECHANICAL DEMOLITION - PHASE 3 - AREA A1
MD-102.3 SECOND LEVEL -MECHANICAL DEMOLITION - PHASE 3
MD-104.3 ROOF LEVEL PLAN - MECHANICAL DEMOLITION - PHASE 3
MH-20G.2.TLS1 GROUND LEVEL - DUCTWORK - PHASE 2 - TEMPORARY LOGISTICS STORAGE #1
MH-20G.2.TLS2 GROUND LEVEL - DUCTWORK - PHASE 2 - TEMPORARY LOGISTICS STORAGE #2
MH-20G.3.A2 GROUND LEVEL - DUCTWORK - PHASE 3 - AREA A2
P-000 PLUMBING SYMBOLS AND ABBREVIATIONS
PD-10B.2.A2 BASEMENT LEVEL - PLUMBING DEMOLITION - PHASE 2
PD-10B.3.A1 BASEMENT LEVEL - PLUMBING - DEMOLITION - PHASE 3 - AREA A1
PD-10G.2.A2 GROUND LEVEL - PLUMBING DEMOLITION - PHASE 2 - AREA A2
PD-10G.3.A1 GROUND LEVEL - PLUMBING DEMOLITION - PHASE 3 - AREA A1
PD-104.3 ROOF LEVEL PLAN - PLUMBING DEMOLITION - PHASE 3 - OVERALL
PP-20B.3.A1 BASEMENT LEVEL - PLUMBING PIPING - PHASE 3 - AREA A1
PP-20B.3.A2 BASEMENT LEVEL - PLUMBING PIPING - PHASE 3 - AREA A2
PP-20G.3.A2 GROUND LEVEL - PLUMBING PIPING - PHASE 3 - AREA A2
PP-20G.4.A1 GROUND LEVEL - PLUMBING PIPING - PHASE 4 - AREA A1
PW-20B.3.A2 BASEMENT LEVEL - PLUMBING DRAINAGE - PHASE 3 - AREA A2
PW-20B.4.A1 BASEMENT LEVEL - PLUMBING DRAINAGE - PHASE 4 - AREA A1
PW-20G.3.A2 GROUND LEVEL - PLUMBING DRAINAGE - PHASE 3 - AREA A2
PW-20G.4.A1 GROUND LEVEL - PLUMBING DRAINAGE - PHASE 4 - AREA A1
PW-202 ROOF LEVEL PLAN - PLUMBING DRAINAGE - PHASE 3
P-400 RO WATER RISER DIAGRAM - PHASE 3 - AREA A2
P-401 DOM WATER AND INSTRUMENT AIR RISER DIAGRAM - PHASE 3 - AREA A2
P-403 WASTE AND VENT RISER DIAGRAM - PHASE 3 - AREA A2
P-405 WASTE, VENT AND WATER RISER DIAGRAMS - PHASE 4 - AREA A1
EP-20G.2.TLS2 GROUND LEVEL - POWER - PHASE 2 - TEMPORARY LOGISTICS STORAGE #2
EP-20G.3.A2 GROUND LEVEL - POWER - PHASE 3 - AREA A2
EP-20G.4.A1 GROUND LEVEL - POWER - PHASE 4 - AREA A1
EP-202.3 SECOND LEVEL - POWER - PHASE 3
EP-206.1 PENTHOUSE ROOF LEVEL - POWER - PHASE 3
ET-20G.2.TLS1 GROUND LEVEL - LOW VOLTAGE - PHASE 2 - TEMPORARY LOGISTICS STORAGE #1
ET-20G.2.TLS2 GROUND LEVEL - LOW VOLTAGE - PHASE 2 - TEMPORARY LOGISTICS STORAGE #2
ET-20G.3.A2 GROUND LEVEL - LOW VOLTAGE - PHASE 3 - AREA A2
ET-20G.4.A1 GROUND LEVEL - LOW VOLTAGE - PHASE 4 - AREA A1
E-500 ONE-LINE DIAGRAM
E-600 ELECTRICAL DETAILS
E-601 ELECTRICAL DETAILS
E-700 ELECTRICAL SCHEDULES
E-701 ELECTRICAL PANEL SCHEDULES
E-702 ELECTRICAL PANEL SCHEDULES
E-703 ELECTRICAL PANEL SCHEDULES
MH-20G.3.A4 GROUND LEVEL - DUCTWORK - PHASE 3 - LOADING DOCK AREA
MH-20G.4.A1 GROUND LEVEL - DUCTWORK - PHASE 4 - AREA A1
MH-202.3 SECOND LEVEL - DUCTWORK - PHASE 3
MP-20G.2.TLS1 GROUND LEVEL - HYDRONIC PIPING - PHASE 2 - TEMPORARY LOGISTICS STORAGE #1
MP-20G.3.A2 GROUND LEVEL - HYDRONIC PIPING - PHASE 3 - AREA A2
MP-20G.4.A1 GROUND LEVEL - HYDRONIC PIPING - PHASE 4 - AREA A1
MP-202.3 SECOND LEVEL - HYDRONIC PIPING - PHASE 3
MP-203.3 THIRD LEVEL -HYDRONIC PIPING -PHASE 3
MP-203.4 ROOF LEVEL -HYDRONIC PIPING -PHASE 3
M-300 DUCTWORK AND PIPING - PHASE 3 - WEST ELEVATIONS
M-303 MECHANICAL ROOM ELEVATIONS - PHASE 3 - 2ND FLOOR MECHANICAL ROOM
M-304 DUCTWORK - PHASE 3 - NORTH ELEVATIONS
M-400 MECHANICAL SCHEMATICS
M-500 MECHANICAL DETAILS
M-501 MECHANICAL DETAILS
M-600 MECHANICAL SCHEDULES
M-601 MECHANICAL SCHEDULES
M-700 MECHANICAL CONTROLS
M-701 MECHANICAL CONTROLS
M-702 MECHANICAL CONTROLS
Electrical
E-000 ELECTRICAL SYMBOLS AND ABBREVIATIONS
E-001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
ED-10G.1.TLS1 GROUND LEVEL - ELECTRICAL DEMOLITION - PHASE 1 - TEMPORARY LOGISTICS STORAGE #1
ED-10G.1.TLS2 GROUND LEVEL - ELECTRICAL DEMOLITION - PHASE 1 - TEMPORARY LOGISTICS STORAGE #2
ED-10G.2.A2 GROUND LEVEL - ELECTRICAL DEMOLITION - PHASE 2 - AREA A2
ED-10G.3.A1 GROUND LEVEL - ELECTRICAL DEMOLITION - PHASE 3 - AREA A1
EL-20G.2.TLS1 GROUND LEVEL - LIGHTING - PHASE 2 - TEMPORARY LOGISTICS STORAGE #1
EL-20G.2.TLS2 GROUND LEVEL - LIGHTING - PHASE 2 - TEMPORARY LOGISTICS STORAGE #2
EL-20G.3.A2 GROUND LEVEL - LIGHTING - PHASE 3 - AREA A2
EL-20G.3.A4 GROUND LEVEL - LIGHTING - PHASE 3 - LOADING DOCK AREA
EL-20G.4.A1 GROUND LEVEL - LIGHTING - PHASE 4 - AREA A1
EJ-20G.2.TLS1 GROUND LEVEL - LIGHTING CONTROL - PHASE 2 - TEMPORARY LOGISTICS STORAGE #1
EJ-20G.2.TLS2 GROUND LEVEL - LIGHTING CONTROL - PHASE 2 - TEMPORARY LOGISTICS STORAGE #2
EJ-20G.3.A2 GROUND LEVEL - LIGHTING CONTROL - PHASE 3 - AREA A2
EJ-20G.4.A1 GROUND LEVEL - LIGHTING CONTROL - PHASE 4 - AREA A1
EP-20G.2.TLS1 GROUND LEVEL - POWER - PHASE 2 - TEMPORARY LOGISTICS STORAGE #1
Sheet Number Sheet Name
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS P.C.
111 WOOD AVENUE SOUTH
SUITE 102
ISELIN, NJ, 08830-4112 U.S.A.
11-07-2025
A u to d e s k D o c s /2
.0
V A
P it ts b u rg
S P
S A
H U a n d
R O
U p g ra d e s /6
-1
.M
E P
.2
.r v t
/7 /2
:4
:1
P
M
GI-000
COVER SHEET UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA 15240
646-21-101
11/07/2025 JLN AEA
646-21-101
PITTSBURGH VAMC UD SPS AHU & RO UPGRADE
U.S. Department of Veterans Affairs
University Drive C, Pittsburgh, PA 15240
Revisions: Date:
ABBREVIATIONS
ACT
A.F.F
ALUM.
APPROX
ASHRAE
ASTM
BLDG
CLG
CMU
CONC
CONT.
DIA
DIM
DWGS
EA
EF
ELEV
ETC.
EQ
EXIST.
F.E.
FIN.FL.LVL.
GA
GWB
HM
HORIZ
HR
HW
I.D.
ACOUSTICAL CEILING TILE
ABOVE FINISHED FLOOR
ALUMINUM
APPROXIMATELY
AMERICAN SOCIETY OF HEATING,
REFRIGERATING, & AIR-CONDITIONING
ENGINEERS
AMERICAN SOCIETY FOR TESTING & MATERIALS
BUILDING
CEILING
CONCRETE MASONRY UNIT
CONCRETE
CONTINUOUS
DIAMETER
DIMENSION
DRAWINGS
EACH
EXHAUST FAN
ELEVATION
ETCETERA
EQUAL
EXISTING
FIRE EXTINGUISHER
FINISHED FLOOR LEVEL
GAUGE
GYPSUM WALLBOARD
HOLLOW METAL
HORIZONTAL
HOUR
HARDWARE
IDENTIFICATION
MAX
MECH.
MIN
M.O.
NFPA
N.I.C.
N.I.S.
NO.
NTS
O.C.
OCC
OSHA
PT
REQ.
RM
R.O.
SS
STL
SF
THK
T.O.
TYP.
UL
V.I.F.
WD
W/ W/O Ø
MAXIMUM
MECHANICAL
MINIMUM
MASONRY OPENING
NATIONAL FIRE PROTECTION
ASSOCIATION
NOT IN CONTRACT
NOT IN SCOPE
NUMBER
NOT TO SCALE
ON CENTER
OCCUPANTS
OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
PAINT
REQUIRED
ROOM
ROUGH OPENING
STAINLESS STEEL
STEEL
SQUARE FEET
THICK
TOP OF
TYPICAL
UNDERWRITER'S LABORATORY
VERIFY IN FIELD
WOOD
WITH
WITHOUT
DIAMETER
AT
AND
CENTERLINE
NUMBER
GENERAL NOTES
1. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO, EXHAUST FANS, CONDUITS, ETC., SHALL BE EXAMINED AND TESTED AS REQUIRED BY THE CONTRACTOR'S LICENSED MECHANICAL AND/OR ELECTRICAL SUB-CONTRACTOR, PRIOR TO THE START OF THE WORK. THE EXAMINATION AND TESTING SHALL BE PERFORMED IN THE PRESENCE OF THE BUILDING MAINTENANCE PERSONNEL. THE CONTRACTOR SHALL SUBMIT WRITTEN NOTIFICATION TO THE OWNER, PRIOR TO START OF THE WORK, IDENTIFYING ALL DAMAGED OR IMPROPERLY FUNCTIONING ITEMS ENCOUNTERED. IF THESE ITEMS ARE NOT IDENTIFIED IN WRITING PRIOR TO THE START OF THE WORK, THEY SHALL BE REPAIRED OR REPLACED AS REQUIRED, AT THE CONTRACTOR'S EXPENSE.
2. ALL WORK, MATERIALS, AND WORKMANSHIP SHALL BE PERFORMED IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, RULES, AND REGULATIONS, TO THE PUBLISHED SPECIFICATIONS, TO THE RECOMMENDED PRACTICES OF THE MANUFACTURERS, AND THE APPROPRIATE APPLICABLE STANDARDS. WHERE SUCH CODES, RULES, AND REGULATIONS ARE AT VARIANCE WITH THE PLANS AND NOTES, THE CODES, RULES, AND REGULATIONS, ETC. SHALL TAKE PRECEDENCE OVER THE PLANS AND
NOTES.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE AND SHALL REPORT ANY DISCREPANCIES TO THE OWNER PRIOR TO STARTING CONSTRUCTION. COMMENCEMENT OF THE WORK BY THE CONTRACTOR SHALL
IMPLY THE ACCEPTANCE OF ALL EXISTING CONDITIONS.
4. ALL WORK SHALL BE EXECUTED IN A CAREFUL AND ORDERLY MANNER WITH THE LEAST POSSIBLE NOISE, DUST, OR DISTURBANCE TO
OCCUPANTS, ADJACENT SITES, OR BUILDINGS.
5. DETAILS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL REQUIREMENTS. DETAILS
NOTED "TYP." IMPLY ALL CONDITIONS TREATED SIMILARLY.
6. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK SHALL
BE INCLUDED AS IF THEY WERE INCLUDED AND INDICATED ON THE DRAWINGS.
7. THE BUILDING SHALL REMAIN ACCESSIBLE TO THE OWNER AT ALL TIMES.
8. FIELD VERIFY CONSTRUCTION AND INSTALLATION REQUIREMENTS.
9. REPRODUCED CONTRACT DRAWINGS WILL NOT BE ACCEPTED AS SHOP DRAWINGS.
10. ALL CONSTRUCTION AND OTHER MATERIALS SHALL BE STORED AT A DESIGNATED STORAGE AREA AND ON COMPLETION OF WORK OR AS DEEMED NECESSARY, ALL SURPLUS/ REFUSE/ DEBRIS MATERIAL SHALL BE REMOVED AND LEGALLY DISPOSED OF OFF-SITE AT NO
ADDITIONAL COST TO THE OWNER.
11. SHOULD DISCREPANCIES OCCUR BETWEEN CONTRACT DRAWINGS AND CONTRACT SPECIFICATIONS, THE CONTRACT SPECIFICATIONS IN CONJUNCTION WITH ALL APPLICABLE CODES, STANDARDS, RULES, REGULATIONS, LAWS, ETC. SHALL TAKE PRECEDENCE OVER THE
CONTRACT DRAWINGS.
12. THE CONTRACTOR SHALL CUT AND REMOVE EXISTING WALL AND FLOOR ASSEMBLIES AS REQUIRED TO INSTALL STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL WORK AND PATCH ALL DISTURBED AREAS.
13. OCCUPATION OF AREAS THAT ARE UNDER THE CONSTRUCTION SCOPE SHOULD BE COORDINATED BY THE CONTRACTOR AS PART OF
THE PHASING PLAN.
14. THE CONSTRUCTION AREA SHALL BE THOROUGHLY CLEANED PRIOR, DURING, AND AFTER THE CONSTRUCTION.
15. THE CONTRACTOR MUST BE FULLY FAMILIAR WITH THE CONDITIONS RELATING TO THE CONSTRUCTION AND LABOR UNDER WHICH THE WORK WILL BE PERFORMED AND COMPARE THE DRAWINGS AND SPECIFICATIONS WITH THE WORK IN PLACE. FAILURE TO DO SO WILL NOT RELIEVE THE CONTRACTOR OF THEIR OBLIGATION TO FURNISH ALL LABOR AND MATERIAL NECESSARY TO CARRY OUT THE PROVISIONS OF THE CONTRACT DOCUMENTS. EACH SUB-CONTRACTOR SHALL EMPLOY CONSTRUCTION MEANS OR METHODS THAT
WILL NOT CAUSE ANY INTERRUPTIONS OR INTERFERENCE WITH THE WORK OF OTHER TRADES.
16. THE CONTRACT DOCUMENTS, INCLUDING SPECIFIC INSTALLATION DETAILS SHOWN ON THE DRAWINGS, ESTABLISH THE MINIMUM INSTALLATION REQUIREMENTS FOR THIS PROJECT. ALL MANUFACTURER'S REQUIREMENTS THAT EXCEED WHAT IS REQUIRED BY THE CONTRACT DOCUMENTS SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR SHALL REVIEW THE DRAWINGS WITH THE MANUFACTURER, PRIOR TO SUBMITTING A BID. ANY MANUFACTURER OBJECTIONS TO DETAILS SHOWN SHALL BE
SUBMITTED TO THE OWNER, PRIOR TO SUBMITTING A BID.
17. PROVIDE BARRICADES, WARNING SIGNS, AND LIGHTS AT OPENINGS AND OTHER AREAS HAZARDOUS TO PEDESTRIANS AND TRAFFIC.
KEEP CONSTRUCTION DEBRIS CLEAR OF TRAFFIC AREAS.
18. ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH THE REGULATIONS AND GUIDELINES SET FORTH BY ALL AGENCIES HAVING JURISDICTION OVER THE WORK. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION (OSHA) RULES AND REGULATIONS.
19. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE BUILDING CODES AND REGULATIONS, PAYMENTS AND OBTAINING ALL NECESSARY AND REQUIRED INSPECTIONS, AND APPROVALS AND PERMITS, NECESSARY TO PERFORM ALL WORK AND
SERVICES HEREIN NOTED OR INDICATED ON THE DRAWINGS.
20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING WATERTIGHT INTEGRITY OF THE BUILDING AT ALL TIMES. ALL WATER DAMAGE SHALL BE REPAIRED AT NO ADDITIONAL COST AND TO THE SATISFACTION OF THE OWNER.
21. THE CONTRACTOR SHALL PROVIDE PROTECTION FOR THE GENERAL PUBLIC AND CONSTRUCTION WORKERS IN AND AROUND THE CONSTRUCTION SITE. ADEQUATE BARRIERS SHALL BE PROVIDED TO EXERCISE CONTROL OF SAFE INGRESS AND EGRESS OF PREMISES.
FIRE EXITS SHALL AT NO TIME BE BLOCKED.
22. ALL ITEMS, SYSTEMS, AND PRODUCTS NOTED ON THE DRAWINGS SHALL BE NEW UNLESS NOTED AS EXISTING.
23. THE APPROVAL OF SUBMITTALS BY THE ENGINEER/ARCHITECT SHALL NOT BE CONSTRUED AS A COMPLETE CHECK, BUT WILL INDICATE ONLY THAT THE GENERAL METHOD OF CONSTRUCTION, MATERIALS, DETAILING, AND OTHER INFORMATION ARE SATISFACTORY.
APPROVAL WILL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR ANY ERROR OR OMISSION, WHICH MAY EXIST IN THE SUBMITTALS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DIMENSIONS AND DESIGN OF ADEQUATE CONNECTIONS, DETAILS, AND SATISFACTORY CONSTRUCTION OF ALL WORK.
24. SUBMITTALS SHALL BE IN COMPLIANCE WITH CONTRACT REQUIREMENTS AND ACTUAL FIELD CONDITIONS. INCOMPLETE SUBMITTALS WILL NOT BE REVIEWED BY THE ENGINEER/ARCHITECT AND WILL BE RETURNED TO THE CONTRACTOR. DELAYS CAUSED BY INCOMPLETE SUBMITTALS SHALL NOT BE EXCUSED AND SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
GENERAL DEMOLITION NOTES
1. THE SCOPE OF DEMOLITION WORK, SPECIFICALLY CUTTING AND PATCHING, SHALL NOT BE LIMITED TO AREAS BEING RENOVATED, BUT SHALL INCLUDE ALL WORK NECESSARY TO COMPLETE THE FINISHED PROJECT TO THE SATISFACTION OF THE OWNER.
2. PRIOR TO THE START OF DEMOLITION, CONTRACTOR SHALL INSPECT AREAS IN WHICH WORK WILL BE PERFORMED. NOTE EXISTING CONDITIONS OF SURFACES, EQUIPMENT, OR SURROUNDING PROPERTY THAT COULD BE MISCONSTRUED AS DAMAGE RESULTING FROM
SELECTIVE DEMOLITION WORK; NOTIFY OWNER PRIOR TO STARTING WORK.
3. THE OWNER ASSUMES NO RESPONSIBILITY FOR ACTUAL CONDITION OF ITEMS OR STRUCTURES TO BE DEMOLISHED OR REMOVED.
4. THE CONTRACTOR SHALL MAKE CONTINUOUS OBSERVATIONS OF THE EXISTING STRUCTURE DURING THE PERFORMANCE OF THE WORK AND SHALL NOTIFY THE OWNER OF ANY CRACKS, DEFLECTIONS, ETC., THAT MAY REQUIRE FURTHER INVESTIGATION.
5. ALL DEMOLITION ACTIVITIES, CUTTING, AND PATCHING REQUIRED IN CONNECTION WITH THE WORK, SHALL BE PERFORMED BY SPECIFIC TRADES INVOLVED AND AS REQUIRED TO EXECUTE EACH LINE OF WORK. ALL PATCHING SHALL BE FINISHED TO MATCH ADJACENT
SURFACES EITHER NEW OR EXISTING TO REMAIN.
6. CONDUIT DEMOLITION OPERATIONS AND REMOVAL OF DEBRIS IN A MANNER TO ENSURE MINIMUM INTERFERENCE WITH WALKS AND
OTHER ADJACENT OCCUPIED AND USED FACILITIES.
7. PROVIDE BARRICADES, WARNING SIGNS, AND LIGHTS AT OPENINGS AND OTHER AREAS HAZARDOUS TO PEDESTRIANS AND TRAFFIC.
KEEP CONSTRUCTION DEBRIS CLEAR OF TRAFFIC AREAS.
8. ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH THE REGULATIONS AND GUIDELINES SET FORTH BY ALL AGENCIES HAVING
JURISDICTION OVER THE WORK.
9. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) RULES
AND REGULATIONS.
10. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), LATEST EDITION.
11. CONTRACTOR SHALL REMOVE AND RELOCATE ALL EXISTING CONDUITS, PIPING, WIRING, UTILITIES, ETC., THAT MAY INTEREFERE WITH
NEW CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER.
12. THE CONTRACTOR SHALL PROTECT AND PRESERVE ALL EXISTING ITEMS TO REMAIN AND SHALL REPAIR AND/OR REPLACE ANY ITEMS DAMAGED DURING THE COURSE OF WORK TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL COST.
13. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE LEGALLY OF OF-SITE.
14. IF ANY EXISTING CONSTRUCTION THAT IS TO REMAIN IN PLACE IS DAMAGED DURING THE PERFORMANCE OF THE WORK, SHALL BE RESTORED TO ITS ORIGINAL CONDITION TO THE SATISFACTION OF THE OWNER AND AT THE CONTRACTOR'S SOLE EXPENSE.
15. EXISTING PENETRATIONS SHOWN ARE NOT ALL-INCLUSIVE. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO
SUBMISSION OF BID.
SYMBOLS
NUMBER
IDENTIFICATION
X
X
ELEVATION
SECTION
X
X
DETAIL
DRAWING NUMBER
WHERE REFERENCE
IS LOCATED
LETTER
IDENTIFICATION
DRAWING NUMBER
WHERE REFERENCE
IS LOCATED
LETTER
IDENTIFICATION
DRAWING NUMBER
WHERE REFERENCE
IS LOCATED
AXXXX
AXXXX
NUMBER
IDENTIFICATION
DRAWING NUMBER
WHERE REFERENCE
IS LOCATED
INTERIOR ELEVATION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS PENN, P.C.
325 CHESTNUT STREET,
SUITE 300
PHILADELPHIA, PA 19016 U.S.A.
A u to d e s k D o c s /2
.0
V
A P it ts b u rg S
P S
A H
U a n d
R O
U p g ra d e s /6
-2
-1
U
D S
P S
A H
U
R O
U p g ra d e A rc h it e c tu re R
.r v t
/6 /2
:2
:2
P
M
GI-002
GENERAL NOTES, SYMBOLS,
ABBREVIATIONS, & CODE DATA
UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA 15240
646-21-101
11/07/2025 DH/LAA MS
TOTAL TRAVEL DISTANCE TO EXIT:
(AMBULATORY HEALTH CARE )
300'-0" MAX W/ SPRINKLERS
297'-10" MAX - SEE LIFE SAFETY
PLAN ON SHEET GI-101
COMMON PATH OF TRAVEL:
(BUSINESS)
100'-0" MAX W/ SPRINKLERS 99'-6" MAX
DEAD END LIMITS (B) 50'-0" MAX NONE
TRAVEL DISTANCE
ACCESSIBLE MEANS OF EGRESS NOT REQUIRED N/A
4 EXITS > 1000 OCCUPANTS N/A
3 EXITS 501-1000 N/ANUMBER OF MEANS OF EGRESS
2 EXITS PER STORY OCCUPANT LOAD 76 = 2 EXITS
EGRESS
MINIMUM CORRIDOR WIDTH: 44" MINIMUM CLEAR
52" CLEAR MINIMUM IN
CORRIDOR CAA1
MIN. DOOR WIDTH 32" CLEAR 33" CLEAR
EGRESS CAPACITY: DOORS .20" PER PERSON 33"
STORAGE: 500 SF PER PERSON
REFER TO LIFE SAFETY PLAN
DWG SHEET GI-101
BUSINESS 150 SF PER PERSON
REFER TO LIFE SAFETY PLAN
DWG SHEET GI-101
OCCUPANT LOAD
ELECTRICAL ROOM 1 HR OR SPRINKLER SYSTEM SPRINKLER SYSTEM PROVIDED
MECHANICAL ROOM 1 HR 1 HR PROVIDED
STORAGE ORDINARY HAZARD SMOKE PARTITION SMOKE PARTITION PROVIDED
ENCLOSURE PROTECTION
AREA:
276,000 S.F. W/ SPRINKLER
MODIFICATION
RENOVATION SCOPE OF
WORK: 12,851 S.F. + 3,121 S.F.
(TEMPORARY STORAGE
ROOMS) = 15,972 S.F.
BUILDING HEIGHT UNLIMITED (A)
EXISTING 4 STORY BUILDING -
NO CHANGE
CONSTRUCTION TYPE: I-(332) (FULLY SPRINKLERED) I-(332) (FULLY SPRINKLERED)
OCCUPANCY CLASSIFICATION:
NFPA 101 & CHAPTER 19 - EXISTING
HEALTH CARE OCCUPANCIES
(BUSINESS)
(B) BUSINESS
CATEGORY CODE ACTUAL
CODE ANALYSIS
SAFETY STANDARDS FOR REFRIGERATION SYSTEMS (ASHRAE STANDARD 15 - 2007)
VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY (ASHRAE 62.1 - 2004)
ENERGY CONSERVATION CODE - ASHRAE 90.1 - 2019
ENERGY POLICY ACT OF 2005 (EPACT)
UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
VA SEISMIC DESIGN REQUIREMENTS (H-18-8)
U.S. DEPARTMENT of VETERANS AFFAIRS FIRE PROTECTION DESIGN MANUAL - REV. 3/1/20
U.S. DEPARTMENT of VETERANS AFFAIRS PLUMBING DESIGN MANUAL - REV. 3/1/20
NATIONAL STANDARD PLUMBING CODE (NSPC)
NFPA 13 SPRINKLER SYSTEMS
INTERNATIONAL MECHANICAL CODE (2018)
NATIONAL ELECTRICAL CODE (2017)
INTERNATIONAL BUILDING CODE (IBC) - WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS
NFPA NATIONAL FIRE CODES, EXCLUDING NFPA 5000 AND NFPA 900
NFPA 99 HEALTH CARE FACILITIES CODE (2021)
NFPA 101 LIFE SAFETY CODE (2024)
APPLICABLE CODES AND STANDARDS
INCLUDE SUPPORTING BEAMS AND
JOISTS
1 1/2 HR 1 1/2 HR
ROOF CONSTRUCTION
INCLUDE SUPPORTING BEAMS AND
JOISTS
2 HR 2 HR
FLOOR CONSTRUCTION
SUPPORTING ROOFS ONLY 2 HR 2 HR
SUPPORTING ONE FLOOR ONLY 3 HR 2 HR
SUPPORTING MORE THAN ONE FLOOR 3 HR 3 HR
INTERIOR BEARING WALLS
SUPPORTING ROOFS ONLY 3 HR 3 HR
SUPPORTING ONE FLOOR ONLY 3 HR 3 HR
SUPPORTING MORE THAN ONE FLOOR 3 HR 3 HR
EXTERIOR BEARING WALLS
SUPPORTING ROOFS ONLY 1 1/2 HR 2 HR
SUPPORTING ONE FLOOR ONLY 2 HR 2 HR
SUPPORTING MORE THAN ONE FLOOR 2 HR 3 HR
BEAMS, GIRDERS, TRUSSES
SUPPORTING ROOFS ONLY 2 HR 2 HR
SUPPORTING ONE FLOOR ONLY 3 HR 2 HR
SUPPORTING MORE THAN ONE FLOOR 3 HR 3 HR
STRUCTURAL FRAME COLUMNS
BUILDING ELEMENT IBC TYPE 1A NFPA TYPE 1 (332)
FIRE RESISTANCE RATINGS OF BUILDING ELEMENTS - IBC TABLE 601 & NFPA 220
TABLE 3-1
D
NOT APPLICABLE
NOT APPLICABLE
SPD - DIRTY & CLEAN
CORRIDOR / MECH AREA
CORRIDOR / RECEIVING
CORRIDOR / STORAGE
CORRIDOR / KITCHEN /
FOOD STORAGE
646-21-101
1 University DR, Pittburgh, PA 15240
MEDIUM /
HIGHEST
X
X
D
MEDIUM /
HIGHEST
X
X
X
SEE
PHASING
PLANS
XX
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS PENN, P.C.
325 CHESTNUT STREET,
SUITE 300
PHILADELPHIA, PA 19016 U.S.A.
A u to d e s k D o c s /2
.0
V
A P it ts b u rg S
P S
A H
U a n d
R O
U p g ra d e s /6
-2
-1
U
D S
P S
A H
U
R O
U p g ra d e A rc h it e c tu re R
.r v t
/6 /2
:2
:2
P
M
GI-003
ICRA ASSESSMENT UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA 15240
646-21-101
11/07/2025 LAA LAARevisions: Date:
8 10 11 12 14 16 17
N
N1
L
J
6 18
AA210
SPS OFFICE
AA310
RES-1 RES-1
P-1 (EPY)
HAC
AA313
DIRTY CART
VESTIBULE
AA311
SHIFT
SUPERVISOR
AA312
SHIFT
SUPERVISOR
AA301
FLEX STORAGE
AA300
SPS BREAKOUT
AA154
CONFERENCE
ROOM
AA201
WATER
TREATMENT
ROOM
AA202
SOILED
ANTEROOM
AA203
VENDOR
DROP-OFF
AA309
LOGISTICS
BREAKROOM
AA308
LOGISTICS
LOCKERS
AA308A
CHANGING
ROOM 1
AA308B
CHANGING
ROOM 2
AA211
SPS OFFICE
AA212
SPS OFFICE
AA220
DECONTAMINATION
AA209
SPS
BREAKROOMAA307
EQUIPMENT
STORAGE
AA305
EMERGENCY
STORAGE
AA304
LOGISTICS
DISPATCH
AREA
CAA3
LOGISTICS
CORRIDOR
AA213
CLEAN
ANTEROOM
AA306
NCRMD
CLEANING
AA206
SPS MEN'S
LOCKER/SHOWER
AA205
ELECTRICAL
AA208
TOILET
AA207
SPS WOMEN'S
LOCKER/SHOWER
AA303
OPEN OFFICE
INVENTORY
MANAGERS /
SUPPLY TECH
AA302
BULK STORAGE
AA217
STERILIZER
CART
COOLDOWN
ROOM
EXISTING OXY
MANF.
STORAGE
EXISTING
MACHINE ROOM
EXISTING
CLEAN
VERTICAL
AA215
STERILE
STORAGE
AA216
CART STORAGE
/ ASSEMBLY /
DISPATCH
EXISTING
TOILET
EXISTING
TOILET
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
OFFICE
EXISTING
STORAGE
EXISTING
CORRIDOR
EXISTING
MECHANICAL
EQUIPMENT
ROOM 'D'
298'
(B)
COMMON PATH = 77'-4"
(A&B)
94'
(A)
263'
(C)
171'
(D)
C O
M M
O N
P A
T H
(C
D
178'
(E)
181'
(F)
COMMON PATH = 99'-6" (E&F)
TO CORRIDOR
CAW24B
TO CORRIDOR
CAA5 EXIT
TO CORRIDOR
CAA3 EXIT
TO STAIR # 2
AA204
LASER
ENGRAVING AA219
HAC
AA218
HAC
G
FE
FE
FE
FE
FE
EXISTING
CORRIDOR
EXISTING
CORRIDOR
CAA4
CORRIDOR
CAA4
CORRIDOR
EXISTING
STORAGE
P1
12 15
M
IN
1' - 6" MIN.
M
IN
" 212'
(G)
TO PASSAGE AN217 EXIT
211'
(H)
COMMON PATH = 86'-0" (G&H)
AA214
SPS CLEAN
SUITE
PREP/
STERILIZATION
EXISTING
BIO-MED
WORKROOM
EXISTING
DATA CLOSET
EXISTING
LOUNGE
EXISTING
MED. GAS
MANIFOLD
EXISTING
ELECTRONIC
SHOP
EXISTING
MECHANICAL
EXISTING
HAC
EXISTING
EMS
CAA2
CORRIDOR
AN205
EXISTING
RECEIVING
ENTRY
AA222
PUMP CL.
AA221
WASHER CART
COOLDOWN
ROOM
AA223
ELEC. CLOSET
15 16
FE
EGRESS DOOR OPENING
MAX. EGRESS CAPACITY (OCCUPANTS)
NET CLEAR EGRESS WIDTH PROVIDED (INCHES)
OCCUPANT LOADXX
XX
LIFE SAFETY LEGEND
EMERGENCY EXIT SIGN, SEE
ELECTRICAL DWGS
2-HR FIRE RATING
FIRE EXTINGUISHER &
CABINET
XXX
XXX
ROOM NUMBER
DESIGN LOAD (OCCUPANTS)
EGRESS ROOM/SPACE AREA TAG
XX COMPONENT I.D.
XXX
REMOTE EXIT ACESS
TRAVEL DISTANCE (IN FEET)
PATH OF TRAVEL TO POINT OF EXIT
ACCUMULATED NUMBER OF OCCUPANTS
ALONG PATH OF TRAVEL
XX
1-HR FIRE RATING
EXISTING 2-HR FIRE RATING
EXISTING WALLS
XX
EXISTING SMOKE BARRIER
NEW PARTITION
NEW SMOKE PARTITION
EXISTING 1-HR FIRE RATING
FE
KEY PLAN
NOT TO SCALE
NORTH
AREA OF
WORK
EXISTING FLOOR
AREA
SMOKE COMPARTMENT MODIFICATION
12,851 S.F.
ADDITIONAL
FLOOR AREA
N/A
TOTAL FLOOR
AREA
12,851 S.F.
MAX. ALLOWABLE FLOOR
AREA PER COMPARTMENT
NOTE: SMOKE COMPARTMENT ARE UNCHANGED FROM EXISTING.
1/8" = 1'-0"
GROUND FLOOR LIFE SAFETY PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS PENN, P.C.
325 CHESTNUT STREET,
SUITE 300
PHILADELPHIA, PA 19016 U.S.A.
A u to d e s k D o c s /2
.0
V
A P it ts b u rg S
P S
A H
U a n d
R O
U p g ra d e s /6
-2
-1
U
D S
P S
A H
U
R O
U p g ra d e A rc h it e c tu re R
.r v t
/6 /2
:2
:3
P
M
GI-101
LIFE SAFETY PLAN UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA 15240
646-21-101
11/07/2025 DH/LAA JD/MS
EGRESS TRAVEL DISTANCES
POINT DISTANCE
MAX ALLOWED AS PER NFPA 101
LIFE SAFETY CODE
(A) 94' - 2" 300'-0" (COMPLIES)
(B) 298' - 2" 300'-0" (COMPLIES)
(C) 263' - 5" 300'-0" (COMPLIES)
(D) 171' - 6" 300'-0" (COMPLIES)
(E) 177' - 11" 300'-0" (COMPLIES)
(F) 181' - 3" 300'-0" (COMPLIES)
(G) 212' - 1" 300'-0" (COMPLIES)
(H) 210' - 10" 300'-0" (COMPLIES)
OCCUPANCY LOAD (AS PER NFPA 101)
ROOM NAME ROOM NUMBER S.F. OCCUPANTS NFPA LOAD FACTOR
PREP/ STERILIZATION 126 SF 1 150 SF / OCCUPANT
CONFERENCE ROOM AA154 109 SF 4 30 SF / OCCUPANT
WATER TREATMENT ROOM AA201 109 SF 1 150 SF / OCCUPANT
SOILED ANTEROOM AA202 82 SF 1 150 SF / OCCUPANT
VENDOR DROP-OFF AA203 45 SF 1 150 SF / OCCUPANT
LASER ENGRAVING AA204 88 SF 1 150 SF / OCCUPANT
ELECTRICAL AA205 53 SF 1 500 SF / OCCUPANT
SPS MEN'S LOCKER/SHOWER AA206 183 SF 2 150 SF / OCCUPANT
SPS WOMEN'S LOCKER/SHOWER AA207 182 SF 2 150 SF / OCCUPANT
SPS BREAKROOM AA209 117 SF 1 150 SF / OCCUPANT
SPS OFFICE AA210 99 SF 1 150 SF / OCCUPANT
SPS OFFICE AA211 88 SF 1 150 SF / OCCUPANT
SPS OFFICE AA212 88 SF 1 150 SF / OCCUPANT
CLEAN ANTEROOM AA213 87 SF 1 150 SF / OCCUPANT
SPS CLEAN SUITE AA214 1357 SF 13 150 SF / OCCUPANT
STERILE STORAGE AA215 1061 SF 3 500 SF / OCCUPANT
CART STORAGE / ASSEMBLY / DISPATCH AA216 471 SF 2 500 SF / OCCUPANT
STERILIZER CART COOLDOWN ROOM AA217 363 SF 2 150 SF / OCCUPANT
HAC AA218 30 SF 1 500 SF / OCCUPANT
HAC AA219 30 SF 1 500 SF / OCCUPANT
DECONTAMINATION AA220 1105 SF 7 150 SF / OCCUPANT
WASHER CART COOLDOWN ROOM AA221 202 SF 2 150 SF / OCCUPANT
PUMP CL. AA222 27 SF 1 500 SF / OCCUPANT
ELEC. CLOSET AA223 47 SF 1 500 SF / OCCUPANT
SPS BREAKOUT AA300 357 SF 3 150 SF / OCCUPANT
FLEX STORAGE AA301 394 SF 1 500 SF / OCCUPANT
BULK STORAGE AA302 2680 SF 6 500 SF / OCCUPANT
OPEN OFFICE INVENTORY MANAGERS /
SUPPLY TECH
AA303 325 SF 3 150 SF / OCCUPANT
LOGISTICS DISPATCH AREA AA304 139 SF 1 150 SF / OCCUPANT
EMERGENCY STORAGE AA305 97 SF 1 500 SF / OCCUPANT
NCRMD CLEANING AA306 250 SF 2 150 SF / OCCUPANT
EQUIPMENT STORAGE AA307 196 SF 1 500 SF / OCCUPANT
LOGISTICS LOCKERS AA308 154 SF 2 150 SF / OCCUPANT
CHANGING ROOM 1 AA308A 45 SF 1 150 SF / OCCUPANT
CHANGING ROOM 2 AA308B 26 SF 1 150 SF / OCCUPANT
LOGISTICS BREAKROOM AA309 240 SF 2 150 SF / OCCUPANT
HAC AA310 59 SF 1 500 SF / OCCUPANT
SHIFT SUPERVISOR AA311 95 SF 1 150 SF / OCCUPANT
SHIFT SUPERVISOR AA312 100 SF 1 150 SF / OCCUPANT
DIRTY CART VESTIBULE AA313 198 SF 2 150 SF / OCCUPANT
TOTAL OCCUPANCY 81
SCALE: 1/8" = 1'-0"
1680 4
DOOR
68" 340
DOOR
32" 160
DOOR
32" 160
DOOR
32" 160
FIRE EXTINGUISHER CALCULATIONS (AS PER NFPA 10)
CLASS CLASSIFICATION QUANTITY
TOTAL FLOOR
AREA
MAX. FLOOR
AREA PER F.E.
MAX. TRAVEL
DISTANCE
A ORDINARY
(MODERATE)
5 12,851 S.F. 11,250 S.F. 75'-0"
UP
KEY PLAN
NOT TO SCALE
NORTH
LOCATION OF
OVERALL
PHASING PLAN
PHASING LEGEND
AREA OF WORK
WALLS TO BE DEMOLISHED
EXISTING STEEL COLUMNS
PHASE UNDER DEMOLITION
EXISTING WALLS TO REMAIN
EXISTING 2-HR FIRE RATING
EXISTING 1-HR FIRE RATING
EXISTING SMOKE BARRIER
NEW PARTITION
1-HR FIRE RATED
2-HR FIRE RATED
NEW SMOKE PARTITION
PRIORITY AREA
8 10 11 12 14 16 17
N
N1
L
J
6 18
G
P1
P
5 2019 21 22 23 24 25
F
E
D
C
B
Q
GI-106
S
GI-106
AREA #1
AREA #2
EXISTING
SOILED RECEIVING &
DECONTAMINATION
AA117
EXISTING
PREPARATION &
STERILIZATION
WORKROOM
AA122
EXISTING
BREAKROOM
AA109
EXISTING
CART WASH
AA110
EXISTING
AUTOMATIC
CART WASH
EXIST.
OFFICE
AA101B
EXIST.
OFFICE
AA101A
EXIST.
OFFICE
AA101
EXIST.
TOILET
AA102
EXIST.
ELEC.
ROOM
AA127
EXIST. HAC
AA128
EXIST.
OFFICE
AA126
EXISTING
SPD - BREAKOUT
AA152
EXISTING
HOLD - BREAKOUT
AA125
EXISTING
STERILE & NON-STERILE
STORAGE
AA106 EXISTING
LOUNGE
AA105
EXIST.
OFFICE
AA104
EXISTING
RECEIVING AND
ISSUING
AA100
EXIST.
OFFICE
EXIST.
OFFICE
EXIST. CORRIDOR
CA3
EXIST.
OFFICE
EXISTING
DISPATCH AREA
AA103
EXISTING
CONFERENCE
ROOM
AA154
EXISTING
MECHANICAL
EQUIPMENT
ROOM 'D'
AA116
EXISTING
LOGISTICS
RECEIVING
AE153
EXIST.
OFFICE
AA153A
EXISTING GIP
OFFICE
AA145
EXISTING
TRAINING ROOM
AE123
EXIST.
OFFICE EXISTING
MACHINE ROOM
AA106A
EXIST. CORRIDOR
CAA1
EXIST. RECEIVING
ENTRY
AN205
EXIST. OXY
MANF. STORAGE
AN206
EXISTING
LOGISTICS AREAEXISTING SPS
AREA
EXIST.
OFFICE
AA145A
EXIST.
OFFICE
AA145C
EXIST. CORRIDOR
CA4
EXIST. CORRIDOR
CA5
EXIST. WIPE
DOWN AREA
AA109
EXIST. WATER
TREATMENT
AA117A
EXISTING FEMALE
LOCKERS
AA111
EXIST. CORRIDOR
CAA1
EXISTING MALE
LOCKERS
AA111
EXISTING
CORRIDOR
CA8
EXISTING
CORRIDOR
CAA5
EXIST.
MECH.
AA131
EXIST. HAC
AA142
EXIST.
TOILET
AA140
EXIST. ETO
ABATER
AA118
EXISTING
STORAGE
EXIST.
CONFERENCE
ROOM
AN220
EXIST.
INT. DESIGN
ROOM
AN215
AREA #3
ICRA LEVEL 2
EXISTING
FMS AREA
ICRA LEVEL 3
ICRA LEVEL 3
1. FMS AREA WILL RELOCATE TO AREA TBD (COORDINATE
WITH VA)
2. EXISTING GIP OFFICE AA145 TO BE RELOCATED TO EXISTING
FMS AREA
PRE-CONSTRUCTION:
1. AREAS #1, #2 AND #3 ARE RENOVATED FOR TEMPORARY USES
2. LOGISTICS STORAGE MOVES TO AREAS #1 AND #2
3. SPS STORAGE MOVES TO AREA #3
PHASE 1:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS PENN, P.C.
325 CHESTNUT STREET,
SUITE 300
PHILADELPHIA, PA 19016 U.S.A.
A u to d e s k D o c s /2
.0
V
A P it ts b u rg S
P S
A H
U a n d
R O
U p g ra d e s /6
-2
-1
U
D S
P S
A H
U
R O
U p g ra d e A rc h it e c tu re R
.r v t
/6 /2
:2
:4
P
M
GI-102
GROUND FLOOR PHASING PLAN -
PHASE 1
UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA 15240
646-21-101
11/07/2025 DH/LAA MS
1/16" = 1'-0"
GROUND FLOOR PHASING PLAN - PHASE 1
SCALE: 1/16" = 1'-0"
32160 8
NOT TO SCALE
NORTH
LOCATION OF
OVERALL
PHASING PLAN
8 10 11 12 14 16 17
N
N1
L
J
6 18
G
P1
P
5 2019 21 22 23 24 25
F
E
D
C
B
Q
P2.3
S
P2.0
P2.2
GI-107
GI-106
P2.1
P2.1
P2.1
P2.1
AREA #1
AREA #2
EXISTING SPS
AREA
EXISTING
SOILED RECEIVING &
DECONTAMINATION
AA117
EXISTING
PREPARATION &
STERILIZATION
WORKROOM
AA122
EXISTING
BREAKROOM
AA109
EXIST. WIPE
DOWN AREA
AA109
EXISTING
CART WASH
AA110
EXISTING
AUTOMATIC
CART WASH
EXIST.
OFFICE
AA101B
EXIST.
OFFICE
AA101A
EXIST.
OFFICE
AA101
EXIST.
TOILET
AA102
EXIST.
ELEC.
ROOM
AA127
EXIST. HAC
AA128
EXIST.
OFFICE
AA126
EXISTING
SPD - BREAKOUT
AA152
EXISTING
HOLD - BREAKOUT
AA125
EXISTING
LOGISTICS
AREA
EXISTING
LOUNGE
AA105
EXIST.
OFFICE
AA104
EXISTING
RECEIVING AND
ISSUING
AA100
EXIST.
OFFICE
EXIST.
OFFICE
EXIST. CORRIDOR
CA3
EXIST.
OFFICE
EXISTING
DISPATCH AREA
AA103
EXISTING
CONFERENCE
ROOM
AA154
EXISTING
MECHANICAL
EQUIPMENT
ROOM 'D'
AA116
EXIST.
OFFICE EXISTING
MACHINE ROOM
AA106A
EXIST. RECEIVING
ENTRY
AN205
EXIST. OXY
MANF.
STORAGE
AN206
EXIST. CORRIDOR
CA4
EXIST. CORRIDOR
CA5
EXISTING
LOGISTICS
RECEIVING
AE153
EXIST.
OFFICE
AA153A
TEMPORARY
LOGISTICS
STORAGE #1
AA145
TEMPORARY
BREAKOUT
SPACE
EXIST. WATER
TREATMENT
AA117A
EXISTING FEMALE
LOCKERS
AA111
EXIST. CORRIDOR
CAA1
EXISTING MALE
LOCKERS
AA111
EXISTING
CORRIDOR
CA8
EXISTING
CORRIDOR
CAA5
EXIST.
MECH.
AA131
EXIST. HAC
AA142
EXIST.
TOILET
AA140
EXIST. ETO
ABATER
AA118
EXISTING
STORAGE
TEMPORARY LOGISTICS
STORAGE #2/
AE123
ICRA LEVEL 4
TEMPORARY
SPS
STORAGE
AREA #3
TEMPORARY SPS
STORAGE
GI-107
TEMPORARY
ANTEROOM
P2.4
P2.5
ELEC
ROOM
AA205
P2.6
*PRIORITY - EXISTING RECEIVING ENTRY AN205 INTO AN206
• NEW DOOR, ACCESS CONTROLS, SUPPLY AND EXHAUST WITH
REQUIRED AIR CHANGES
• WORK DURATION LIMITED TO (2) DAYS NON-BUSINESS HOURS
(WEEKEND)
1. EXISTING LOGISTICS AREA IS RENOVATED TO NEW SPS
2. SPS RELOCATED TO NEW SPACE
PHASE 2:
PHASING LEGEND
AREA OF WORK
WALLS TO BE DEMOLISHED
EXISTING STEEL COLUMNS
PHASE UNDER DEMOLITION
EXISTING WALLS TO REMAIN
EXISTING 2-HR FIRE RATING
EXISTING 1-HR FIRE RATING
EXISTING SMOKE BARRIER
NEW PARTITION
1-HR FIRE RATED
2-HR FIRE RATED
NEW SMOKE PARTITION
PRIORITY AREA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS PENN, P.C.
325 CHESTNUT STREET,
SUITE 300
PHILADELPHIA, PA 19016 U.S.A.
A u to d e s k D o c s /2
.0
V
A P it ts b u rg S
P S
A H
U a n d
R O
U p g ra d e s /6
-2
-1
U
D S
P S
A H
U
R O
U p g ra d e A rc h it e c tu re R
.r v t
/6 /2
:2
:4
P
M
GI-103
GROUND FLOOR PHASING PLAN -
PHASE 2
UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA 15240
646-21-101
11/07/2025 DH/LAA MS
1/16" = 1'-0"
GROUND FLOOR PHASING PLAN - PHASE 2
PHASE 2 KEYNOTES FOR EXISTING LOGISTICS AREA
# COMMENT
P2.0 CHANGE EXISTING DOOR LOCKSETS TO CONSTRUCTION LOCKSETS.
P2.1 CONFIRM IF EXISTING WALLS EXTEND TO DECK ABOVE. EXTEND WALL TO CREATE
CONSTRUCTION BARRIER IF NEEDED. SEE WALL TYPE TP2 ON SHEET GI-108.
P2.2 CONSTRUCT TEMPORARY 1-HOUR RATED CONSTRUCTION PARTITION.
P2.3 COMPLETE DEMOLITION AND CONSTRUCTION IN THIS AREA AS INDICATED IN THE
CONSTRUCTION DRAWINGS.
P2.4 PRIORTIZE DOOR DURING CONSTRUCTION PHASE TO MINMIZE INTERUPTIONS TO
FUNCTION OF ROOM AN206, LIMIT DISPLACEMENT TO TWO DAYS MAX
P2.5 TEMPORARY NEGATIVE PRESSURE ANTE-ROOM FOR CONSTRUCTION ACTIVITIES
P2.6 CONSTRUCT ELECTRIC ROOM AA205 BEFORE EXISTING SPS IS DEMOLISHED
TP3
SCALE: 1/16" = 1'-0"
32160 8
NOT TO SCALE
NORTH
LOCATION OF
OVERALL
PHASING PLAN
8 10 11 12 14 16 17
N
N1
L
J
6 18
G
P1
P
5 2019 21 22 23 24 25
F
E
D
C
B
Q
S
NEW
SPS
AREA
P3.1
P3.0
P3.3
P3.3
P3.3
P3.3
P3.3
P3.3
P3.2
STERILE
STORAGE
CART STORAGE
/ ASSEMBLY /
DISPATCH
SPS CLEAN
SUITE
DECONTAMINATION
STERILIZER
CART
COOLDOWN
ROOMCLEAN
ANTEROOM
CONFERENCE
ROOM
WATER
TREATMENT
ROOM
SOILED
ANTEROOM /
CART DROP
VENDOR
DROP-OFF
LASER
ENGRAVING
ELECTRICAL
ROOM
SPS MEN'S
LOCKER/SHOWER
SPS WOMEN'S
LOCKER/SHOWER
CORRIDORSPS OFFICE
SPS OFFICE
SPS OFFICE
SPS BREAK
ROOM
LOGISTICS
CORRIDOR
TOILET
EXISTING
MACHINE ROOM
EXISTING
CLEAN
VERTICAL
PREP/
STERILIZATION
HAC
HAC
EXIST. WATER
TREATMENT
AA117A
EXISTING
SOILED RECEIVING &
DECONTAMINATION
AA117
EXISTING
PREPARATION &
STERILIZATION
WORKROOM
AA122
EXISTING FEMALE
LOCKERS
AA111
EXISTING
BREAKROOM
AA109
EXISTING
CART WASH
AA110
EXISTING
AUTOMATIC
CART WASH
EXISTING
MECHANICAL
EQUIPMENT
ROOM 'D'
AA116
EXISTING
STORAGE
EXIST. ETO
ABATER
AA118
EXIST. CORRIDOR
CAA1
EXIST. CORRIDOR
CA4
EXIST. CORRIDOR
CA5
EXIST. WIPE
DOWN AREA
AA109
EXIST. RECEIVING
ENTRY
AN205
EXIST. OXY
MANF. STORAGE
AN206
EXISTING
LOGISTICS
RECEIVING
AE153
EXIST.
OFFICE
AA153A
TEMPORARY
BREAKOUT
SPACE
PUMP CL.
WASHER CART
COOLDOWN
ROOM
ELEC. CLOSET
EXISTING MALE
LOCKERS
AA111
EXISTING
CORRIDOR
CA8
EXISTING
CORRIDOR
CAA5
EXIST.
MECH.
AA131
EXIST. HAC
AA142
EXIST.
TOILET
AA140
TEMPORARY
LOGISTICS
STORAGE #1
AA145
TEMPORARY LOGISTICS
STORAGE #2/
AE123
NEW
LOGISTICS
AREA
(ICRA LEVEL 4)
TEMP ANTE-ROOM
1 HR
CONSTRUCTION
BARRIER
P3.7
P3.8
*PRIORITY - EXISTING CORRIDOR CA5
• REMOVE TEMPORARY PARTITION ACROSS EGRESS
CORRIDOR
• ADD 1-HR RATED CORRIDOR WALL AT SOUTH WALL OF
EXISTING CORRIDOR CA4 AND NEW SPS OFFICE TO PROVIDE
CONTINUOUS PATH OF EGRESS FROM NEW SPS AREA
1. EXISTING SPS AREA RENOVATED TO NEW LOGISTICS AREA
2. LOGISTICS MOVES INTO NEW SPACE
PHASE 3:
PHASING LEGEND
AREA OF WORK
WALLS TO BE DEMOLISHED
EXISTING STEEL COLUMNS
PHASE UNDER DEMOLITION
EXISTING WALLS TO REMAIN
EXISTING 2-HR FIRE RATING
EXISTING 1-HR FIRE RATING
EXISTING SMOKE BARRIER
NEW PARTITION
1-HR FIRE RATED
2-HR FIRE RATED
NEW SMOKE PARTITION
PRIORITY AREA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS PENN, P.C.
325 CHESTNUT STREET,
SUITE 300
PHILADELPHIA, PA 19016 U.S.A.
A u to d e s k D o c s /2
.0
V
A P it ts b u rg S
P S
A H
U a n d
R O
U p g ra d e s /6
-2
-1
U
D S
P S
A H
U
R O
U p g ra d e A rc h it e c tu re R
.r v t
/6 /2
:2
:5
P
M
GI-104
GROUND FLOOR PHASING PLAN -
PHASE 3
UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA 15240
646-21-101
11/07/2025 DH/LAA MS
SCALE: 1/16" = 1'-0"
32160 8
1/16" = 1'-0"
GROUND FLOOR PHASING PLAN - PHASE 3
PHASE 3 KEYNOTES
# COMMENT
P3.0 CHANGE EXISTING DOOR LOCKSETS TO CONSTRUCTION LOCKSETS.
P3.1 COMPLETE DEMOLITION AND CONSTRUCTION IN THIS AREA AS INDICATED IN
CONSTRUCTION DRAWINGS.
P3.2 CONSTRUCT TEMPORARY CONSTRUCTION PARTITION.
P3.3 CONFIRM IF EXISTING WALLS EXTEND TO DECK ABOVE. EXTEND WALL TO CREATE
CONSTRUCTION BARRIER IF NEEDED. SEE WALL TYPE TP2 ON SHEET GI-108.
P3.7 TEMPORARY NEGATIVE PRESSURE ANTE-ROOM FOR CONSTRUCTION ACTIVITIES
P3.8 DOOR, FRAME, ASSOCIATED HARDWARE AND CONTROLS TO BE REMOVED AND
REPLACED - COORDINATE WITH VA PHASING SEQUENCE
TP3
NOTE: COORDINATE TESTING OF NEW SPS PRIOR TO SHUTTING DOWN EXISTING SPS -
SEE MEP DRAWINGS
NOT TO SCALE
NORTH
LOCATION OF
OVERALL
PHASING PLAN
8 10 11 12 14 16 17
N
N1
L
J
6 18
G
P1
P
5 2019 21 22 23 24 25
F
E
D
C
B
Q
S
EXISTING
MACHINE ROOM
EXISTING
CLEAN
VERTICAL
SPS BREAKOUT
SPS
BREAKROOM
SPS OFFICE
SPS OFFICE
STERILE
STORAGE
CART STORAGE
/ ASSEMBLY /
DISPATCH
STERILIZER
CART
COOLDOWN
ROOM
CLEAN
ANTEROOM
SPS MEN'S
LOCKER/SHOWER
SPS WOMEN'S
LOCKER/SHOWER
ELECTRICAL
TOILET
LASER
ENGRAVING
VENDOR
DROP-OFF
SOILED
ANTEROOM
WATER
TREATMENT
ROOM
DECONTAMINATION
HAC
HAC
CONFERENCE
ROOM
CORRIDOR
P4.0
P4.0
BULK STORAGE
FLEX STORAGE
DIRTY CART
VESTIBULE
SHIFT
SUPERVISOR
SHIFT
SUPERVISOR
HAC
OPEN OFFICE
INVENTORY
MANAGERS /
SUPPLY TECH
NCRMD
CLEANING
LOGISTICS
DISPATCH
AREA
LOGISTICS
CORRIDOR
EQUIPMENT
STORAGE
EMERGENCY
STORAGE
LOGISTICS
LOCKERS
CHANGING
ROOM 1
CHANGING
ROOM 2
SPS OFFICE
LOGISTICS
BREAKROOM
AREA #1
AREA #2
NEW
LOGISTICS
AREA
SPS CLEAN
SUITE
EXISTING
LOGISTICS
RECEIVING
AE153
EXIST.
OFFICE
AA153A
EXISTING
MECHANICAL
EQUIPMENT
ROOM 'D'
AA116
EXIST. CORRIDOR
CA5
EXIST. RECEIVING
ENTRY
AN205
EXIST. OXY
MANF. STORAGE
AN206
EXISTING GIP
OFFICE
AA145
EXISTING TRAINING
ROOM
AE123
PUMP CL.
WASHER CART
COOLDOWN
ROOM
ELEC. CLOSET
EXIST. CORRIDOR
CAA1
EXISTING
CORRIDOR
CA8
EXISTING
CORRIDOR
CAA5
EXIST.
MECH.
AA131
EXIST. HAC
AA142
EXIST.
TOILET
AA140
GI-107
TEMPORARY
BREAKOUT
SPACE
AREA #3
ICRA LEVEL 2
NEW
SPS
AREA
ICRA LEVEL 3
ICRA LEVEL 3
P4.0
P4.0
AREAS #1, #2 AND #3 RENOVATED BACK TO USABLE
SPACES TBD - COORDINATE WITH VA
PHASE 4:
PHASING LEGEND
AREA OF WORK
WALLS TO BE DEMOLISHED
EXISTING STEEL COLUMNS
PHASE UNDER DEMOLITION
EXISTING WALLS TO REMAIN
EXISTING 2-HR FIRE RATING
EXISTING 1-HR FIRE RATING
EXISTING SMOKE BARRIER
NEW PARTITION
1-HR FIRE RATED
2-HR FIRE RATED
NEW SMOKE PARTITION
PRIORITY AREA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS PENN, P.C.
325 CHESTNUT STREET,
SUITE 300
PHILADELPHIA, PA 19016 U.S.A.
A u to d e s k D o c s /2
.0
V
A P it ts b u rg S
P S
A H
U a n d
R O
U p g ra d e s /6
-2
-1
U
D S
P S
A H
U
R O
U p g ra d e A rc h it e c tu re R
.r v t
/6 /2
:2
:5
P
M
GI-105
GROUND FLOOR PHASING PLAN -
PHASE 4
UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA 15240
646-21-101
11/07/2025 DH/LAA MS
SCALE: 1/16" = 1'-0"
32160 8
1/16" = 1'-0"
GROUND FLOOR PHASING PLAN - PHASE 4
PHASE 4 KEYNOTES
# COMMENT
P4.0 REMOVE STORAGE EQUIPMENT AND REINSTALL EXISTING FURNITURE AS
DIRECTED BY OWNER.
S
8 10 11 12
P
Q
P1.10
P1.11
P1.4
P1.4
P1.5
P1.3
EXISTING CORRIDOR
CAA1
± 54' - 8"
P1.4
P1.2
P1.2
P1.0
P1.1
P1.3
P1.1
EXISTING GIP
OFFICES
AA145
EXISTING
LOGISTICS
RECEIVING
AE153
EXISTING
OFFICE
AA145A
EXISTING
OFFICE
AA145C
P1.10
P1.10 P1.11
P1.11
P1.11
P1.0
P1.6
± 14' - 0"
P1.18
P1.11
8 10 11 12
P
Q
EXISTING
CORRIDOR
CAA1
EXISTING GIP OFFICES
AA145
EXISTING
LOGISTICS
RECEIVING
AA153
± 14' - 0"
P1.12
P1.13 P1.13
P1.16
23 24
D
C
B
RAMP UP RAMP UP
P1.3
± 32' - 1"
P1.0 P1.0
P1.1
P1.1 P1.1
P1.1P1.1
EXISTING
TRAINING
ROOM
AE123
EXISTING
OFFICE
AE124
P1.18
KEY PLAN
NOT TO SCALE
NORTH
TEMPORARY
LOGISTICS
STORAGE #2
TEMPORARY
LOGISTICS
STORAGE #1
TEMPORARY SPS
STAGING STORAGE /
OFFICE AREA
PHASING LEGEND
AREA OF WORK
WALLS TO BE DEMOLISHED
EXISTING STEEL COLUMNS
PHASE UNDER DEMOLITION
EXISTING WALLS TO REMAIN
EXISTING 2-HR FIRE RATING
EXISTING 1-HR FIRE RATING
EXISTING SMOKE BARRIER
NEW PARTITION
1-HR FIRE RATED
2-HR FIRE RATED
NEW SMOKE PARTITION
PRIORITY AREA
23 24
TS5TS5
TS4
TS7 TS7 TS7 TS7
TS2
TS6
TS2
TS1 TS1 TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS2
TS6
TS2
TS2
TS6
TS2
TS2
TS6
TS2
TEMPORARY LOGISTICS STORAGE #2
RAMP
UP
D
C
B
± 32' - 1"
TS4
TS4 TS4
TS8
TS8
RAMP
UP T
U G
P A
T H
I N
T U
G P
A T
H O
U T
P1.9
EXISTING
OFFICE
AE124
P1.14 P1.14
ITEM NO.
PHASING PLAN STORAGE EQUIPMENT LEGEND
COUNT DESCRIPTION
EXISTING LOGISTICS STORAGE (FOR REFERENCE)
- 88 5-TIER SHELVES
- 9 4-TIER WIRE SHELVES
- 4 7-TIER BASKETS
- 5 CARTS
ITEM NO. COUNT DESCRIPTION
TEMPORARY LOGISTICS STORAGE #1
TS1 60 HIGH DENSITY 5-TIER SHELVES
TS2 0 4-TIER WIRE SHELVES
TS3 0 7-TIER BASKETS
TS4 4 CARTS
TS5 2 WORKSTATIONS
ITEM NO. COUNT DESCRIPTION
TS1 33 HIGH DENSITY 5-TIER SHELVES
TS2 8 4-TIER WIRE SHELVES
SIZE
2' X 5' X 6'-8"
2' X 6'
2' X 2'
SIZE
2' X 5' X 6'-8"
2' X 6'
2' X 2'
5' X 5'
SIZE
2' X 5' X 6'-8"
2' X 6'
TEMPORARY LOGISTICS STORAGE #2
TS6 4 4-TIER WIRE SHELVES
TS7 4 7-TIER BASKETS
2' X 4'
1' X 6' X 2'
TS4 4 CARTS
TS5 2 WORKSTATIONS
5' X 5'
TS8 2 TUG -
TEMPORARY SPS STAGING STORAGE / OFFICE AREAS
ITEM NO. COUNT DESCRIPTION
TS9 18 CASE CARTS
TS10 7 SHELVES
SIZE
2'-4" X 4'-0"
4'-0" X 2'-0"
TS11 20 STORAGE UNITS 2'-6" X 1'-6"
NEW/EXISTING
NEW/EXISTING
NEW/EXISTING
NEW/EXISTING
9 CONTRACTOR
PROVIDED - 24 EXISTING -
RELOCATED - PROVIDE
NEW TOP RAILS FOR ALL
EXISTING - RELOCATED -
PROVIDE NEW TOP RAILS
NEW - VA PROVIDED
EXISTING - RELOCATED -
PROVIDE NEW TOP RAILS
EXISTING - RELOCATED
CONTRACTOR PROVIDED
CONTRACTOR PROVIDED
EXISTING - RELOCATED
EXISTING - REMAPPED
NEW - VA PROVIDED
EXISTING - RELOCATED
NEW - VA PROVIDED
NEW - VA PROVIDED
EXISTING - RELOCATED
EXISTING - RELOCATED
NOTE: CONTRACTOR RESPONSIBLE FOR TOP RAILS AT APPROPIATE LENGTH FOR BOTH RELOCATED AND NEW
EQUIPMENT - CONFIRM EQUIPMENT WITH VA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS PENN, P.C.
325 CHESTNUT STREET,
SUITE 300
PHILADELPHIA, PA 19016 U.S.A.
A u to d e s k D o c s /2
.0
V
A P it ts b u rg S
P S
A H
U a n d
R O
U p g ra d e s /6
-2
-1
U
D S
P S
A H
U
R O
U p g ra d e A rc h it e c tu re R
.r v t
/6 /2
:2
:0
P
M
GI-106
ENLARGED PHASING PLANS AREA
1 & 2 - PHASE 1
UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA 15240
646-21-101
11/07/2025 DH/LAA MS
3/16" = 1'-0"
PHASE 1 - EXISTING GIS OFFICE PLAN (DEMOLITION) - AREA #1
3/16" = 1'-0"
PHASE 1 - EXISTING GIS OFFICE RCP (DEMOLITION) - AREA #1
PHASE 1 KEYNOTES
# COMMENT
P1.0 CHANGE EXISTING DOOR LOCKSETS TO CONSTRUCTION LOCKSETS. COORDINATE
REQUIRED HARDWARE WITH VA.
P1.1 CONFIRM IF EXISTING WALLS EXTEND TO DECK ABOVE. EXTEND WALL TO CREATE
CONSTRUCTION BARRIER IF NEEDED. SEE WALL TYPE TP2 ON SHEET GI-108.
P1.2 EXISTING DOOR TO BE TEMPORARILY CLOSED FOR DURATION OF ALL PHASES.
P1.3 REMOVE EXISTING FURNITURE - CONTRACTOR TO DISCARD FURNITURE
P1.4 REMOVE CUBICLE PARTITIONS AND ASSOCIATED MOUNTING HARDWARE -
CONTRACTOR TO DISCARD CUBICLES
P1.5 REMOVE PORTION OF EXISTING WALL TO ACCOMODATE NEW DOOR OPENING.
P1.6 REPAIR OR MODIFY EXISTING FLOOR FINISHES AS NEEDED TO ACCOMODATE NEW
TEMPORARY SPACES.
P1.7 CONSTRUCT NEW WALL.
P1.8 INSTALL DOOR, FRAME, AND HARDWARE.
P1.9 INSTALL STORAGE EQUIPMENT. REFER TO EQUIPMENT LEGEND.
P1.10 REMOVE EXISTING DOOR, FRAME, AND ASSOCIATED HARDWARE IN ITS ENTIRETY.
P1.11 DEMOLISH EXISTING WALLS IN THEIR ENTIRETY.
P1.12 REMOVE PORTION OF EXISTING ACT CEILING PANELS. CUT AT NEAREST EXISTING
TILE GRID. PROVIDE NEW ACT PANELS & MAINTAIN EXISTING CEILING HEIGHT.
P1.13 REMOVE EXISTING ACT CEILING PANELS, SUSPENSION SYSTEM IN THEIR
ENTIRETY - RETAIN LIGHT FIXTURES AND ALL CEILING DEVICES FOR
REINSTALLATION
P1.14 CONTRACTOR TO REROUTE TUG SYSTEM TO TEMP STORAGE AREAS, AS
CONSTRUCTION IS OCCURING AND AS PART OF NEW WORK AS REQUIRED
P1.15 INSTALL STORAGE EQUIPMENT. REFER TO EQUIPMENT LEGEND.
P1.16 EXISTING ACT CEILING PANELS, SUSPENSION SYSTEM, LIGHT FIXTURES, AND
MECHANICAL DEVICES TO REMAIN - SEE MEP DRAWINGS
P1.17 INSTALL NEW ACT SUSPENDED CEILING AND INTEGRATE PATTERN AND GRID INTO
EXISTING - SEE MEP DRAWINGS
P1.18 REMOVE EXISTING CARPET AND PREPARE ROOM TO RECEIVE NEW LVT
FLOORING
3/16" = 1'-0"
PHASE 1 - EXISTING TRAINING ROOM (DEMOLITION) - AREA #2
SCALE: 3/16" = 1'-0"
1680 4
SCALE: 3/16" = 1'-0"
1680 4
SCALE: 3/16" = 1'-0"
1680 4
SCALE: 3/16" = 1'-0"
1680 4
3/16" = 1'-0"
PHASE 1 - TEMPORARY LOGISTICS STORAGE #2 - AREA #2
ITEM NO.
PHASING PLAN STORAGE EQUIPMENT LEGEND
COUNT DESCRIPTION
EXISTING LOGISTICS STORAGE (FOR REFERENCE)
- 88 5-TIER SHELVES
- 9 4-TIER WIRE SHELVES
- 4 7-TIER BASKETS
- 5 CARTS
ITEM NO. COUNT DESCRIPTION
TEMPORARY LOGISTICS STORAGE #1
TS1 60 HIGH DENSITY 5-TIER SHELVES
TS2 0 4-TIER WIRE SHELVES
TS3 0 7-TIER BASKETS
TS4 4 CARTS
TS5 2 WORKSTATIONS
ITEM NO. COUNT DESCRIPTION
TS1 33 HIGH DENSITY 5-TIER SHELVES
TS2 8 4-TIER WIRE SHELVES
SIZE
2' X 5' X 6'-8"
2' X 6'
2' X 2'
SIZE
2' X 5' X 6'-8"
2' X 6'
2' X 2'
5' X 5'
SIZE
2' X 5' X 6'-8"
2' X 6'
TEMPORARY LOGISTICS STORAGE #2
TS6 4 4-TIER WIRE SHELVES
TS7 4 7-TIER BASKETS
2' X 4'
1' X 6' X 2'
TS4 4 CARTS
TS5 2 WORKSTATIONS
5' X 5'
TS8 2 TUG -
TEMPORARY SPS STAGING STORAGE / OFFICE AREAS
ITEM NO. COUNT DESCRIPTION
TS9 18 CASE CARTS
TS10 7 SHELVES
SIZE
2'-4" X 4'-0"
4'-0" X 2'-0"
TS11 20 STORAGE UNITS 2'-6" X 1'-6"
NEW/EXISTING
NEW/EXISTING
NEW/EXISTING
NEW/EXISTING
9 CONTRACTOR
PROVIDED - 24 EXISTING -
RELOCATED - PROVIDE
NEW TOP RAILS FOR ALL
EXISTING - RELOCATED -
PROVIDE NEW TOP RAILS
NEW - VA PROVIDED
EXISTING - RELOCATED -
PROVIDE NEW TOP RAILS
EXISTING - RELOCATED
CONTRACTOR PROVIDED
CONTRACTOR PROVIDED
EXISTING - RELOCATED
EXISTING - REMAPPED
NEW - VA PROVIDED
EXISTING - RELOCATED
NEW - VA PROVIDED
NEW - VA PROVIDED
EXISTING - RELOCATED
EXISTING - RELOCATED
NOTE: CONTRACTOR RESPONSIBLE FOR TOP RAILS AT APPROPIATE LENGTH FOR BOTH RELOCATED AND NEW
EQUIPMENT - CONFIRM EQUIPMENT WITH VA
PHASING LEGEND
AREA OF WORK
WALLS TO BE DEMOLISHED
EXISTING STEEL COLUMNS
PHASE UNDER DEMOLITION
EXISTING WALLS TO REMAIN
EXISTING 2-HR FIRE RATING
EXISTING 1-HR FIRE RATING
EXISTING SMOKE BARRIER
NEW PARTITION
1-HR FIRE RATED
2-HR FIRE RATED
NEW SMOKE PARTITION
PRIORITY AREA
8 10 11 12
P
AISLE
4' - 6"
AISLE
4' - 6"
AISLE
4' - 6"
TS4
(5
R O
L L
IN
G
C A
G E
S
F C
C S
T O
R A
G E
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
TS1
P1.8
P1.7
TS5
TS5
TS4TS4TS4
Q
± 14' - 0"
ALIGN1
R .O
" TP1
TP1
± 54' - 8"
P1.6
P1.7
P1.8
P1.9
EXISTING
LOGISTICS
RECEIVING
AE153
EXISTING CORRIDOR
CAA1
TEMPORARY
LOGISTICS
STORAGE #1
TEMPORARY
BREAKOUT
SPACE
8 10 11 12
P
Q
EXISTING GIP OFFICES /
TEMPORARY LOGISTICS
STORAGE #1
TEMPORARY
BREAKOUT
SPACE
P1.17
A L
IG
N
W
IT
H N
E A
R E
S T
E X
IS
T
IN
G
A C
T
ALIGN WITH NEAREST EXISTING ACT
± 14' - 0"
± 54' - 8"
P1.17
P1.17
18 2019 21
S
TS9 TS9TS9
TS9TS9TS9
TS9TS9TS9
TS9TS9TS9
TS9TS9TS9
TS9TS9TS9
EXISTING
OFFICE
AN221
TEMPORARY
SPS OFFICE
AN218
TEMPORARY
SPS OFFICE
AN219
TS10
TS10
TS10
TS10
TS10
TS10
TS10
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TS11
TEMPORARY
STORAGE
AN215
TEMPORARY
STORAGE
AN220
EXISTING PASSAGE
AN217
EXISTING OFFICE
AN222
EXISTING OFFICE
AN223
EXISTING OFFICE
AN225
EXISTING
CORRIDOR
CAN51
EXISTING
TOILET
AN224
P1.15
P1.15
P1.15
P1.15P1.15
P1.0
P1.0
KEY PLAN
NOT TO SCALE
NORTH
TEMPORARY
LOGISTICS
STORAGE #2
TEMPORARY
LOGISTICS
STORAGE #1
TEMPORARY SPS
STAGING STORAGE /
OFFICE AREA
18 2019 21
S
± 11' - 10" ± 12' - 10" ± 17' - 11"
± 16' - 9"
EXISTING PASSAGE
AN217
EXISTING OFFICE
AN222
EXISTING OFFICE
AN223
EXISTING OFFICE
AN225
EXISTING
CORRIDOR
CAN51
EXISTING
TOILET
AN224
EXISTING
INTERIOR DESIGN
OFFICE
AN215
EXISTING
OFFICE
AN221
EXISTING
OFFICE
AN218
EXISTING
OFFICE
AN219
EXISTING
CONFERENCE ROOM
AN220
P1.18
P1.18
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1300 Baxter St.
Suite 230 Charlotte, NC 28204 Phone: 704.348.3097 www.specializedeng.com
SES Project : 22164.001
MOTT MACDONALD
ARCHITECTS PENN, P.C.
325 CHESTNUT STREET,
SUITE 300
PHILADELPHIA, PA 19016 U.S.A.
A u to d e s k D o c s /2
.0
V
A P it ts b u rg S
P S
A H
U a n d
R O
U p g ra d e s /6
-2
-1
U
D S
P S
A H
U
R O
U p g ra d e A rc h it e c tu re R
.r v t
/6 /2
:2
:0
P
M
GI-107
ENLARGED PHASING PLANS AREA
1 & 3 - PHASE 1
UD SPS AHU & RO UPGRADE,
PITTSBURGH VAMC
University Drive C, Pittsburgh, PA…
This is the start of the file's text. The full file is on GovTribe.