This Product Data Sheet describes Carlisle's Sure-Weld TPO reinforced membrane, a heat-weldable, single-ply thermoplastic polyolefin roofing system designed for new construction and re-roofing applications in conjunction with a Hawaii state contract opportunity for temporary roof repairs at the Honokaa State Office Building. The Department of Accounting and General Services (DAGS), Central Services Division, is soliciting bids for either a Snap-Clad metal roofing overlay system or a TPO membrane overlay system to address active water infiltration at the facility. The Sure-Weld TPO membrane is available in multiple thicknesses—45-mil, 60-mil, and 80-mil Extra—and in standard colors (white, slate gray, gray, medium bronze, tan, terra cotta, patina green, and rock brown) as well as limited special colors. The membrane is manufactured with polyester fabric encapsulation between TPO-based plies, providing high breaking and tearing strength, excellent puncture resistance, and a monolithic roof assembly when heat-welded. Installation methods include fully-adhered, mechanically fastened, and induction-welded applications, with the system requiring minimal labor and components.
The Sure-Weld TPO membrane exceeds ASTM D6878 material specifications through enhanced testing protocols, including heat aging tests exceeding 128 weeks at 240°F (compared to the ASTM requirement of 32 weeks), Q-Trac weathering equivalent to 40 years of real-world exposure, and environmental cycling tests combining heat aging, water immersion, and xenon-arc exposure. The product features OctaGuard XT weathering technology, up to 10% pre-consumer recycled content, and is free of Living Building Challenge red list chemicals. Sure-Weld TPO holds UL 2218 Class 4 hail rating, NSF P151 certification for rainwater catchment (white only), and California Title 24 compliance (white and tan only). The membrane is manufactured at facilities in Senatobia, Mississippi; Tooele, Utah; and Carlisle, Pennsylvania. The product can be ordered with optional APEEL Protective Film for additional protection during installation and can be supplied in field sheets ranging from 8 to 16 feet in width, with 16-foot widths reducing seams by up to 60 percent compared to 10-foot alternatives.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
E X P E R I E N C E T H E C A R L I S L E D I F F E R E N C E
Reinforced Membrane
Overview
Carlisle’s Sure-Weld TPO reinforced membrane is a premium, heat-weldable, single-ply thermoplastic polyolefin (TPO) sheet designed for new roof construction and re-roofing applications. Sure-Weld High Slope (HS) membrane is formulated with additional flame retardant for higher-slope fire code approvals. Sure-Weld Extra is 80 mils (2.03 mm) thick for significantly higher strength and weatherability.
Sure-Weld TPO membranes use advanced polymerization technology that combines the flexibility of ethylene-propylene (EP) rubber with the heat weldability of polypropylene. All Sure-Weld TPO membranes include OctaGuard XT™, an industry-leading, state-of-the-art weathering package.
OctaGuard XT technology enables Sure-Weld TPO to withstand the extreme weatherability testing that is intended to simulate exposure to severe climates.
Physical properties of the membrane are enhanced by a strong polyester fabric that is encapsulated between the TPO-based top and bottom plies.
The combination of the fabric and TPO plies provides high breaking and tearing strength, as well as excellent puncture resistance. The relatively smooth surface of the membrane produces a total surface fusion weld that results in a consistent, watertight, monolithic roof assembly. The membrane is environmentally friendly and safe to install.
Features and Benefits
» Living Building Challenge “Red List Free” – Declare Label
» Sure-Weld TPO is available in 4- and 6-ft (121.92 cm and 182.88 cm) perimeter sheets and 8-, 10-, 12-, and 16-ft (243.84 cm, 304.80 cm,
365.76 cm, and 487.68 cm) Sure-Weld field sheets*
» Outstanding puncture resistance and excellent fire resistant assemblies
» Environmentally friendly and stable formulation
» Excellent resistance to impact and low temperatures
» UL 2218 Class 4 hail rating
» Manufactured with non-halogenated flame retardants
» Excellent chemical resistance to acids, bases and restaurant exhaust emissions
» Exceptional resistance to heat, solar UV, ozone and oxidation
» Manufactured using a hot-melt extrusion process for complete scrim encapsulation
» Enhanced with the OctaGuard XT weathering package
» Standard Colors:
» Special Colors:
*�Sure-Weld HS Special Color TPO membranes are available in limited sizes.
Refer to Carlisle’s Sure-Weld TPO Color Palette Sell Sheet for details.
Sure-Weld 80-mil in special colors are limited to warranties up to 20 years.
Sustainable Attributes
Carlisle SynTec Systems’ focus has always been innovation — Innovation to solve problems, improve performance, reduce labor, and above all, improve sustainability. Carlisle is committed to driving sustainable and efficient processes in the design and manufacturing of our products.
» Up to 10% pre-consumer recycled content
» Fully recyclable when used in mechanically attached systems
» 3rd-party verified Environmental Product Declaration available
» NSF P151 certification for rainwater catchment**
» California Title 24 compliant***
» Free of Living Building Challenge red list chemicals
**White only, produced in Tooele, UT and Carlisle, PA ***White and Tan only
Installation
Sure-Weld TPO roofing systems are quick to install, as minimal labor and few components are required. TPO systems are installed using an Automatic Heat Welder, making sheet welding fast, clean, consistent, and easy to learn, while reducing strain on the roofing technician.
White
Slate Gray
Gray
Med Bronze
Tan
Terra Cotta Patina Green Rock Brown
Reinforced Membrane
Fully-Adhered – membrane is adhered to a suitable substrate utilizing an appropriate bonding adhesive
Mechanically Fastened – membrane is attached to the roof deck over a suitable substrate utilizing plates and fasteners which are overlapped with membrane
Induction-Welded – membrane is attached over a suitable substrate via an induction welding tool being placed over the membrane where a fastened TPO induction welding plate is located to weld the two components together
Review Carlisle specifications and details for complete installation information.
Precautions » Sunglasses that filter out ultraviolet light are strongly recommended, as tan and white surfaces are highly reflective. Roofing technicians should dress appropriately and wear sunscreen.
» Surfaces may become slippery due to frost and ice buildup. Exercise caution during cold conditions to prevent falls. Exercise caution when walking on wet membrane. Membranes may be slippery when wet.
» Care must be exercised when working close to a roof edge when the surrounding area is snow-covered, as the roof edge may not be clearly visible.
» Use proper stacking procedures to ensure sufficient stability of the rolls.
» Store membrane in the original undisturbed plastic wrap in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. Membrane that has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot-air welding.
» Take care not to stand or place heavy objects on the edge of folded-over membrane, as this could cause a hard crease in the membrane.
» Maximum sustained temperature not to exceed 160°F (71°C) for TPO membrane.
» Do not use razor blades or other sharp tools to cut the APEEL Protective Film while it is still adhered to the TPO membrane as damage to the underlying membrane may occur. Pull the protective film away from the membrane prior to cutting.
» Remove APEEL Protective Film by pulling towards the center of the roof. Do not remove the film by pulling towards the roof edge.
» A static electric charge may develop when removing APEEL Protective Film from the surface of the membrane sheet. To avoid the possibility of ignition, lids must be closed on any flammable products and a fire extinguisher should be readily available.
» Color membranes will ‘fade’ over time mainly due to the ultraviolet portion of sunlight. Since most roof surfaces are exposed to variable sunlight, some areas will be more susceptible to color changes caused by UV fading. Warranties for color membranes do not cover fading of colors.
Extreme Testing for Severe Climates
ASTM Standard D6878 is the material specification for Thermoplastic Polyolefin-Based Sheet Roofing. It covers material property requirements for TPO roof sheeting and includes initial and aged properties after heat and xenon-arc exposure. As stated in the scope of the standard, “the tests and property limits used to characterize the sheet are values intended to ensure minimum quality for the intended purpose.” Carlisle’s goal is to produce TPO that delivers maximum performance for the intended purpose of roofing membranes. Maximum performance requires the membrane to far exceed the requirements of ASTM D6878.
Wider is Better Carlisle’s 16-foot Sure-Weld TPO delivers a leap in productivity on adhered and induction welded roofs by cutting down on the number of rolls needed and dramatically reducing the number of seams on the roof.
With fewer rolls to load, stage, and kick out, and fewer seams to weld, contractors can save significant time on each project, moving on to the next one sooner.
16-Foot TPO Benefits
» Fewer rolls to load and stage on a job saves crane time and labor at the beginning of each project
» Fewer rolls to position, kick-out, and align during installation saves labor
» Up to 60% fewer seams vs. 10-foot TPO
» Fewer seams to weld, probe, and inspect, saving considerable time during installation
» Fewer T-joint patches to install on each roof
» Less waste and trash from packaging
» Less time spent on each project, allowing contractors to complete more roofs and grow their business
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
Heat Aging accelerates the oxidation rate that roughly doubles for each 18°F (10°C) increase in roof membrane temperature. Oxidation (reaction with oxygen) is one of the primary chemical degradation mechanisms of roofing materials.
Carlisle Testing – Heat Aging
ASTM Requirement Sure-Weld Requirement
ASTM TEST
240°F
32 weeks** >128 weeks
**Heat exposure comparable to 3,120 weeks (60 years) at 185°F for 8 hours/day.
» Test specimen is a 2" by 6" (50.8 mm by 152.4 mm) piece of 45-mil (1.14 mm) membrane unbacked, placed in circulating hot-air oven.
» Criterion – no visible cracks after bending aged test specimen around 3" (76.2 mm)-diameter mandrel.
Q-Trac testing combines accelerated weathering with real-world conditions using an array of ten mirrors to reflect and concentrate full spectrum sunlight onto membrane test specimens. The Q-Trac device automatically tracks the sun’s path from morning to night. Also, it adjusts to compensate for seasonal changes in the sun’s altitude. Eight years in Q-Trac testing is equal to 40 years of real-world exposure. Carlisle requires its Sure-Weld TPO membranes to pass the equivalent of 40 years of exposure in the Q-Trac.
Carlisle Testing – Q-Trac
ASTM D6878 Requirement Sure-Weld Requirement
ASTM TEST
N/A
N/A Equivalent of 40 years of exposure
Environmental Cycling subjects the membrane to repeated cycles of heat aging, hot-water immersion, and xenon-arc exposure.
» ASTM requirement – none
» Carlisle Extreme test*:
- 10 days heat aging at 240°F (116°C) followed by
- 5 days water immersion at 158°F (70°C) followed by
- 5,040 kJ/m² (2000 hours at 0.70 W/m² irradiance) xenon-arc exposure
*�Test specimen is 2.75" (69.85 mm by 140 mm) by 5.5" piece of membrane with edges sealed.
*�Criterion – after 3 complete cycles, test specimens shall remain flexible and not have any cracking under 10x magnification while wrapped around a 3" (76.2 mm)-diameter mandrel.
Supplemental Approvals, Statements and Characteristics:
1. Sure-Weld TPO meets or exceeds the requirements of ASTM D6878 Standard Specification for Thermoplastic Polyolefin-Based Sheet Roofing.
2. Sure-Weld TPO membranes conform to requirements of the US E.P.A. Toxic Leachate Test (40 CFR part 136) performed by an independent analytical laboratory.
3. Sure-Weld TPO was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact head.
45-mil (1.14 mm) was watertight after an impact energy of 12.5 J (9.2 ft-lbf) and 60-mil (1.52 mm) was watertight after 22.5 J (16.6 ft-lbf). 80-mil (2.03 mm) Extra was watertight after an impact energy of 30.0 J (22.1 ft-lbf).
4. All FM approved assemblies have been tested to pass FM 4470 for foot traffic resistance.
Optional APEEL™ Protective Film
Shield Carlisle’s Sure-Weld TPO membrane from dirt and scuffs during installation with APEEL Protective Film. Factory-applied and easy to remove, APEEL eliminates the need for rooftop cleaning upon project completion.
» Ideal for re-roofing, re-cover, and new construction projects
» Simple and easy to remove
» Saves time and money when compared to pressure washing
» Protecting from dirt maintains maximum membrane reflectivity and long-term performance
Installation
Simply order membrane with APEEL, install, and remove the film to reveal a clean, new roof.
» APEEL Protective Film should be removed from within areas that are to be heat-welded together. In areas that do not require heat-welding, the APEEL Protective Film can be left in place for up to 90 days without degrading due to its excellent heat- and UV-resistance.
» When the installation of the entire TPO roofing system is complete, remove and discard the APEEL Protective Film.
Reinforced Membrane
800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com
04.14.25 © 2025 Carlisle.
REPRINT CODE: 600515 TPO-2012 - “Sure-Weld TPO Reinforced Membrane Product Data Sheet”
US PATENT NUMBERS: 8,833,037 • 9,163,140 • 10,422,138 • 10,801,207
Carlisle, Sure-Weld, OctaGuard XT, and APEEL are trademarks of Carlisle.
LEED is a registered trademark of the U.S. Green Building Council.
LEED Information Pre-consumer Recycled Content 10%
Post-consumer Recycled Content 0%
Manufacturing Location Senatobia, MS Tooele, UT Carlisle, PA
Solar Reflectance Index (SRI) 99 (white) 86 (tan)
Radiative Properties for Cool Roof Rating Council (CRRC) and LEED
Test Method
White
TPO
Tan
TPO
Gray
TPO
CRRC –
Initial solar reflectance
ASTM
C1549
0.79 0.71 0.46
CRRC – Solar reflectance after 3 years
ASTM
C1549 (uncleaned)
0.70 0.64 0.43
CRRC – Initial thermal emittance
ASTM
C1371
0.90 0.86 0.89
CRRC – Thermal emittance after 3 years
ASTM
C1371 (uncleaned)
0.86 0.87 0.88
LEED – Thermal emittance
ASTM
E408
0.90 0.86 0.85
SRI – Initial (Solar Reflectance Index)
ASTM
E1980
99 86 52
SRI – 3 year aged (Solar Reflectance Index)
85 77 49
Radiative Properties (Initial) for Special Colors
Reflectance Emittance SRI Medium Bronze 0.12 0.89 8
Rock Brown 0.23 0.88 23
Slate Gray 0.20 0.89 18
Terra Cotta 0.25 0.88 24
Patina Green 0.25 0.88 25
Solar Reflectance Index (SRI) is calculated per ASTM E1980.
The SRI is a measure of the roof’s ability to reject solar heat, as shown by a small temperature rise. It is defined so that a standard black (reflectance 0.05, emittance 0.90) is 0 and a standard white (reflectance 0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100.
Typical Properties and Characteristics
Physical Property ASTM D6878 Requirement
45-mil (1.14 mm)
60-mil (1.52 mm)
80-mil Extra (2.03 mm)
Tolerance on Nominal Thickness, % ASTM D751 test method
+15, -10 ± 10 ± 10 ± 10
Thickness Over Scrim, in. (mm) ASTM D7635 optical method, average of 3 areas
0.015 min (0.380)
0.018 typical (0.457)
0.024 typical (0.610)
0.034 typical (0.864)
Breaking Strength, lbf (kN) ASTM D751 grab
220 (976 N) min
225 (1.0) min 320 (1.4) typical
250 (1.1) min 360 (1.6) typical
350 (1.6) min 425 (1.9) typical
Elongation Break of Reinforcement, % ASTM D751 grab method
15 min 15 min 25 typical
15 min 25 typical
15 min 25 typical
Tearing Strength, lbf (N) ASTM D751 proc. B 8 in. x 8 in.
55 (245) min 55 (245) min 130 (578) typical
55 (245) min 130 (578) typical
55 (245) min 130 (578) typical
Brittleness Point, °F (°C)
ASTM D2137
-40 (-40) max -40 (-40) max -50 (-46) typical
-40 (-40) max -50 (-46) typical
-40 (-40) max -50 (-46) typical
Linear Dimensional Change, % ASTM D1204, 6 hours at 158°F
± 1 max ± 1 max -0.2 typical
± 1 max -0.2 typical
± 1 max -0.2 typical
Ozone Resistance, no cracks 7X ASTM D1149, 100 pphm, 168 hrs
PASS PASS PASS PASS
UV Exposure (Xenon Arc), no cracks 7X ASTM G155, min.
exposure 10,080 kJ/m2 (4,000 hrs - 0.70 W/m2)
PASS PASS PASS PASS
Water Absorption Resistance, mass % ASTM D471 top surface only 166 hours at 158°F water
± 3.0 max ± 3.0 max
0.90 typical
± 3.0 max
0.90 typical
± 3.0 max
0.90 typical
Factory Seam Strength, lbf (N) ASTM D751 grab method
66 (290) min 66 (290) min 66 (290) min 66 (290) min
Field Seam Strength, lbf/in (kN/m) ASTM D1876 tested in peel
No requirement 25 (4.4) min 50 (8.8) typical
25 (4.4) min 60 (10.5) typical
40 (7.0) min 70 (12.3) typical
Water Vapor Permeance, Perms ASTM E96 proc. B
No requirement 0.10 max
0.05 typical
0.10 max
0.05 typical
0.10 max
0.05 typical
Puncture Resistance, lbf (kN) FTM 101C, method 2031 (see supplemental section)
No requirement 250 (1.1) min 325 (1.4) typical
300 (1.3) min 350 (1.6) typical
400 (1.8) min 450 (2.0) typical
Properties After Heat Aging ASTM D573, 32 weeks @ 240°F or 8 weeks @ 275°F No cracking when bent around 3" diameter mandrel Weight Change, %
PASS
No cracking ± 1.5 max
1.0 max
1.0 max
1.0 max
Typical Weights lb/ft² (kg/m²) 0.25 0.33 0.45
Air Permeance, ASTM E2178 No Requirement PASS PASS PASS