Summary: 6-JSD Portable Classroom Remodel Drawings

This document consists of architectural design drawings for a portable classroom remodel project for the Jordan School District (JSD) in Utah. The drawings provide detailed floor plans, reflected ceiling plans, building sections, and construction details for a single-module portable classroom renovation. The project includes the installation of custom casework elements such as a teacher's wardrobe cabinet with adjustable shelving, moveable file drawers with locking casters, a marker board, and a hat and coat rack. The specifications reference compliance with the 2012 International Building Code (IBC) and 2009 International Energy Conservation Code (IECC). Key mechanical and electrical components are noted, including roof vents, metal gutters and downspouts, vented soffit and fascia, metal siding, interior wall finishes with tackable board, carpet installation, insulated doors and windows, and ceiling-mounted projection equipment. The drawings are dated 03/02/2026 and indicate that exact locations of certain components require coordination with the owner prior to installation.

The drawings specify finishes and materials including birch plywood casework with stain and varnish coating, plastic laminate surfaces for moveable components, gypsum board painted walls, and acoustic tile suspended ceiling systems. Details call for solid wood blocking for attachment of casework and fixtures, with specific hardware requirements such as Ives No. 405 brushed chrome coat hooks. The document notes that carpet and carpet base are to be provided by the owner. Multiple construction details are referenced but not fully illustrated on this sheet, requiring cross-reference to supplementary detail sheets (B through M) for complete specifications on doors, windows, cabinetry, roof attachments, and mechanical systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VENT

5'-7" 28'-0" 5'-7"

A

ALTERNATE

DOOR LOCATION

F.E.C.

5'-10 1/2"

Floor Plan Scale: 1/8" 1'-0"

S

S D

3-4" 3'-2"

A101

A Classroom

(F1 B1)

A102

20'-3"

5'-10 1/2"

32'-0"

9'-0"

C1

P

E.P.

E

OPP

H

A101

Reflected Ceiling Plan E Scale: 1/8" 1'-0"

2" CUT-OUT WITH

1 1/2" RADIUS

CORNERS (VENT

SPACE)

9"

EO

a

8" CLEAR

TOP VIEW

ADJUSTABLE SHELVING

TOP SECTION

ABOVE FIXED SHELF

VIEW

2'-8" 3'-0"

SECTION

8"

CLEAR

FRONT VIEW

H

-ROD & SHELF

VENT

1" ADJ. SHELVES

TOP

SECTION

-WARDROBE

CABINET

LOCK

ELECTRICAL &

A/V DEVICES

PULL

VENT

MOVEABLE

FILE DRAWERS

- SEE J/A102

Teacher's Wardrobe Scale: 3/4" 1'-0"

1" ADJ. SHELVES

1" ADJ. SHELVES

1" FIXED SHELF

2'-3"

SECTION VIEW

7'-0"

-ELBOW

CATCH

2'-8"

J 1'-0"

6" 6" о

D

Building Section Scale: 1/8" 1'-0"

OPP

J

A101

Building Section Scale: 1/8" 1'-0"

2'-8"

30" DEEP

4-4"

Σ H

A101

J

A101

9'-0"

NOTE: 3/4" BIRCH PLYWOOD WITH 1/2" BRICH EDGING ALL SIDES STAIN AND VARNISH

COAT HOOKS - IVES NO. 405 HOOK (BRUSHED CHROME)

PROVIDE SOLID 2x WALL BLOCKING FOR ATTACHMENT

Moveable File Drawers Scale: 3/4" 1'-0"

(4) FILE DRAWERS

WITH LOCKS

PLASTIC LAMINATE

SIDES WITH METAL

FRAME

(4) CASTERS WITH

FRONT (2) LOCKABLE

8'-0" „0-,8

W2 W1

B1 B1 W2 4-4"

7'-0" W1

2'-0" 8'-0" E.P.

W2

B1 B1 8'-0" 7'-0"

(2) SHELVES

1'-6" 2'-6"

0-

302m 302m 302m W1 36 14 36

36 14

302m

36 14 48 32 441m

FE

B1

FE

W2

ᄆᄆ

FE

OO FE

آکا

(4) EQUAL SPACED

VERTICAL POSTER

BOARD DIVIDERS

ᄆᄆᄆ

2260m 530m

24 36 24 36 24 B1 48 32

LOCK

3'-0" 3'-0" 3'-0" 3'-0" 4'-0"

3'-0" INFILL

19'-0"

XX

Finish Schedule

F1 Carpet by owner

B1 Carpet base by owner

W1

Gypsum board painted

Tackable wall board over gypsum board primed with metal

W2 perimeter trim install behind casework high

C1

2X4 suspension ceiling system with lay in acoustic tile сл

7'-0" W1

F.E.C.

W2 L/A102

Keyed Notes Code compliance: 2012 IBC and 2009 IECC

Insulated hollow metal door and frame - painted - 3'-0" x 7'-0" x 1 3/4" hardware group 1 see details D/A102 & E/A102 - verify location with owner prior to install

Vinyl flanged window insulated lowe glass 3'-9" wide x 3'-0" see details F/A102 & G/A102 - verify location with owner prior to install

12ft x 4ft marker board

Custom casework install 2x6 solid blocking for attachment

Hat and coat rack see detail C/A102

SEE DETAIL H/A102

FOR TEACHER'S WARDROBE DETAILS

(5) DOUBLE EQUAL

SPACED DRAWERS

JSD PORTABLE

CLASSROOM REMODEL

JORDAN J

SCHOOL DISTRICT

Mechanical unit refer to mechanical drawings SEE DETAIL B/A102 & M/A102

Asphalt shingles over 30lb felt install 36" wide strip of ice and water shield at each rake and eave

Roof vents (2) per side with 40sqin minimum of free area -

4" x 22ga metal gutter and downspouts as shown - attach

MARK

DATE

DESCRIPTION

CAD FILE:

DWG

gutter with spike and sleeves at 3'-0" o.c. see detail K/A102 for downspout attachment

DRAWN BY:

JSD

CHECKED BY:

Vented metal soffit and fascia

APPROVED BY:

12" x 24" metal gable end vent, bug screen with 1/4" maximum holes

DATE:

03/02/2026

DWG TITLE:

Pre-finished horizontal metal siding

OSB panel siding - painted

Light fixture refer to electrical

6" x 24" painted metal vent (3) per side

Return air grille refer to mechanical

Projection screen (50" x 80")

DWG NO:

Projector location of ceiling mounted projector is shown schematically; exact location needs to be coordinated with specific projector requirements and owner prior to rough-in.

22" x 30" attic access above see detail F/A101

SHEET

REV:

OF

A

File details come from the government source that posted it. Updated .