This document package outlines construction requirements for an EHRM Infrastructure Upgrades project at the Lexington-Cooper VA Medical Center in Lexington, KY. The solicitation is for construction services to upgrade mechanical, electrical, plumbing and technology infrastructure throughout multiple buildings. Work includes demolition, abatement, and new construction. The project scope encompasses upgrades to HVAC, electrical systems, fire protection, plumbing, and technology infrastructure across approximately 6 floors of buildings 1 and 1A. The construction documents package includes plans, specifications, details and schedules for architectural, structural, MEP and technology work. The solicitation number is 36C77623B0069 and was issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, TX. The estimated award date is not provided.

View the file

Other files

File Type Posted
596A4-22-700 Responses to Tech Questions - 1-25-24.pdf PDF
36C77623B0069 0008.pdf PDF
596A4-22-700 Responses to Tech Questions - 1-22-24.pdf PDF
36C77623B0069 0007.pdf PDF
36C77623B0069 0006.pdf PDF
596A4-22-700 Responses to Tech Questions - 1-18-24.pdf PDF
36C77623B0069 0005.pdf PDF
596A4-22-700 Responses to Tech Questions - 1-12-24.pdf PDF
36C77623B0069 0004.pdf PDF
596A4-22-700 Security Requirements.pdf PDF
DBA Wage Rates - Fayette County - 01-05-24.pdf PDF
596A4-22-700 Smoke Shack.pdf PDF
596A4-22-700 Handrail Submittal.pdf PDF
596A4-22-700 Drawing M-701 - Mechanical Controls.pdf PDF
596A4-22-700 Specification 23 09 23 - DDC for HVAC.pdf PDF
DBA Wage Rates - Fayette County - 12-22-23.pdf PDF
36C77623B0069 0003.pdf PDF
36C77623B0069 0002.pdf PDF
596A4-22-700 Site Visit Sign-in Sheet - 11-28-23.pdf PDF
36C77623B0069 0001.pdf PDF
596A4-22-700 Drawings 12 - Security.pdf PDF
Limitations on Subcontracting - Construction.docx DOCX document
596A4-22-700 Drawings 03 - Arch.pdf PDF
596A4-22-700 Drawings 06 - Mechanical.pdf PDF
596A4-22-700 Specifications.pdf PDF
596A4-22-700 Drawings 07 - Electrical.pdf PDF
596A4-22-700 Drawings 05 - Plumbing.pdf PDF
596A4-22-700 Drawings 09 - Tech 2.pdf PDF
596A4-22-700 Drawings 10 - Tech 3.pdf PDF
596A4-22-700 Drawings 04 - Fire Protection.pdf PDF
DBA Wage Rates - Fayette County - 09-08-23.pdf PDF
596A4-22-700 Asbestos Inspection Report.pdf PDF
596A4-22-700 Drawings 11 - Tech 4.pdf PDF
596A4-22-700 Brand Name Justification.pdf PDF
IFB 36C77623B0069.docx DOCX document
596A4-22-700 Drawings 02 - Asbestos.pdf PDF
596A4-22-700 Drawings 08 - Tech 1.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT MANAGEMENT,

ARCHITECTURE, & TECHNOLOGY

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com

LEXINGTON VA HEALTH CARE SYSTEM - BOWLING CAMPUS

1101 VETERANS DRIVE

LEXINGTON, KY 40502

EHRM INFRASTRUCTURE UPGRADES

PROJECT #596A4-22-700

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

ARCHITECT OF RECORDCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

569A4-22-700

5/16/23

100% CONSTRUCTION

DOCUMENTS

LEXINGTON-COOPER EHRM

INFRASTRUCTURE DESIGN

1101 VETERANS DRIVE

LEXINGTON, KY 40502

GI-000

COVER SHEET

RAC

SECURITY & MEP

6 S. Old Orchard Ave.

Webster Groves, MO 63119

Phone: 314-918-8383 www.rossbar.com

ABATEMENT

8000 IH 10 W, Ste 600 San Antonio, Texas 78230

Phone: (661)203-8172 www.Desert-Concepts.com

5/16/23

INDEX OF DRAWINGS

GENERAL

GI-000 COVER SHEET

GI-010 INDEX OF DRAWINGS

GI-020 GENERAL INFORMATION, SYMBOLS, & LOCATION MAP

GI-030 ARCHITECTURAL ABBREVIATIONS

GI-040 ACCESSIBILITY STANDARDS

GI-041 ACCESSIBILITY STANDARDS

GI-042 ACCESSIBILITY STANDARDS

GI-043 ACCESSIBILITY STANDARDS

GI-044 ACCESSIBILITY STANDARDS

ASBESTOS

HA-100-1A.G FLOOR PLAN - GROUND FLOOR - AREAS D & PA

HA-103-1.G FLOOR PLAN - GROUND FLOOR - AREA A

HA-113-1.1 FLOOR PLAN - FIRST FLOOR - AREA A

HA-123-1.2 FLOOR PLAN - SECOND FLOOR - AREA A

HA-133-1.3 FLOOR PLAN - THIRD FLOOR - AREA A

HA-143-1.4 FLOOR PLAN - FOURTH FLOOR - AREA A

HA-161-1.6 FLOOR PLAN - SIXTH FLOOR - AREA A

ARCHITECTURAL

AS-100-1A.G FLOOR PLAN - GROUND FLOOR - AREAS D & PA

AS-101-1A.G FLOOR PLAN - GROUND FLOOR - AREA PA

AS-102-1.G FLOOR PLAN - GROUND FLOOR - AREA B

AS-103-1.G FLOOR PLAN - GROUND FLOOR - AREA A

AS-104-1.G FLOOR PLAN - GROUND FLOOR - AREA B & A

AS-110-1A.1 FLOOR PLAN - FIRST FLOOR - AREAS D & E

AS-111-1A.1 FLOOR PLAN - FIRST FLOOR - AREA C

AS-112-1.1 FLOOR PLAN - FIRST FLOOR - AREA B

AS-113-1.1 FLOOR PLAN - FIRST FLOOR - AREA A

AS-114-1.1 FLOOR PLAN - FIRST FLOOR - AREAS B & A

AS-120-1A.2 FLOOR PLAN - SECOND FLOOR - AREA D

AS-121-1A.2 FLOOR PLAN - SECOND FLOOR - AREA C

AS-122-1.2 FLOOR PLAN - SECOND FLOOR - AREA B

AS-123-1.2 FLOOR PLAN - SECOND FLOOR - AREA A

AS-124-1.2 FLOOR PLAN - SECOND FLOOR - AREA A

AS-130-1A.3 FLOOR PLAN - THIRD FLOOR - AREA D

AS-131-1A.3 FLOOR PLAN - THIRD FLOOR - AREA C

AS-132-1.3 FLOOR PLAN - THIRD FLOOR - AREA B

AS-133-1.3 FLOOR PLAN - THIRD FLOOR - AREA A

AS-134-1.3 FLOOR PLAN - THIRD FLOOR - AREA A

AS-140-1A.4 FLOOR PLAN - FOURTH FLOOR - AREA D

AS-141-1A.4 FLOOR PLAN - FOURTH FLOOR - AREA C

AS-142-1.4 FLOOR PLAN - FOURTH FLOOR - AREA B

AS-143-1.4 FLOOR PLAN - FOURTH FLOOR - AREA A

AS-144-1.4 FLOOR PLAN - FOURTH FLOOR - AREA A

AS-150-1A.5 FLOOR PLAN - FIFTH FLOOR - AREA C

AS-151-1A.5 FLOOR PLAN - FIFTH FLOOR - AREA C

AS-152-1.5 FLOOR PLAN - FIFTH FLOOR - AREA B

AS-153-1.5 FLOOR PLAN - FIFTH FLOOR - AREA A

AS-154-1.5 FLOOR PLAN - FIFTH FLOOR - AREA A

AS-160-1.6 FLOOR PLAN - SIXTH FLOOR - AREA B

AS-161-1.6 FLOOR PLAN - SIXTH FLOOR - AREA A

AS-162-1.6 FLOOR PLAN - SIXTH FLOOR - AREA A

AS-200-1.G ENLARGED FLOOR PLAN - GROUND - TR A002C

AS-201-1.G ENLARGED FLOOR PLAN - GROUND - DATA CENTER A073

AS-202-1.G ENLARGED FLOOR PLAN - GROUND - DATA CENTER A073

AS-203-1A.G ENLARGED FLOOR PLAN - GROUND - PA09 & PA10

AS-204-1A.G ENLARGED FLOOR PLAN - GROUND - TR D007D

AS-205-1A.G ENLARGED FLOOR PLAN - GROUND - TR B046A

AS-206-1A.G ENLARGED FLOOR PLAN - GROUND - STORAGE PA07

AS-207-1A.G ENLARGED FLOOR PLAN - GROUND - TR A022

AS-210-1A.1 ENLARGED FLOOR PLAN - 1ST FLOOR - TR C121

AS-211-1.1 ENLARGED FLOOR PLAN - 1ST FLOOR - TR A104

AS-212-1A.1 ENLARGED FLOOR PLAN - 1ST FLOOR - TR B125

AS-220-1A.2 ENLARGED FLOOR PLAN - 2ND FLOOR - TR C222

AS-221-1.2 ENLARGED FLOOR PLAN - 2ND FLOOR - TR A243

AS-230-1A.3 ENLARGED FLOOR PLAN - 3RD FLOOR - TR C333

AS-231-1.3 ENLARGED FLOOR PLAN - 3RD FLOOR - TR A345

AS-240-1A.4 ENLARGED FLOOR PLAN - 4TH FLOOR - TR CU411

AS-241-1.4 ENLARGED FLOOR PLAN - 4TH FLOOR - TR A450

AS-250-1A.5 ENLARGED FLOOR PLAN - 5TH FLOOR - TR C580

AS-251-1.5 ENLARGED FLOOR PLAN - 5TH FLOOR - TR AU547

AS-260-1.6 ENLARGED FLOOR PLAN - 6TH FLOOR - TR A627

AS-270 ENLARGED FLOOR PLAN - VERTICAL PATHWAYS

AS-300 ROOF PLAN

AS-310 ROOF PLAN DETAILS

AS-400 INTERIOR ELEVATIONS

AS-500 PARTITION TYPES

AS-600 DOOR SCHEDULE, DOOR & FRAME TYPES

AS-610 DOOR & MISCELLANEOUS DETAILS

AS-700 ROOM FINISH SCHEDULE & MATERIAL SCHEDULE

AS-710 PHOTOS/EXISTING CONDITIONS

AS-711 PHOTOS/EXISTING CONDITIONS

FIRE PROTECTION

FP-000 FIRE PROTECTION SYMBOLS AND ABBREVIATIONS

FP-100-1A.G OVERALL GROUND FLOOR PLAN - AREA D & PA - FIRE PROTECTION

FP-101-1.G OVERALL GROUND FLOOR PLAN - AREA A - FIRE PROTECTION

FP-102-1.G OVERALL GROUND FLOOR PLAN - AREA B - FIRE PROTECTION

FP-111-1A.1 OVERALL FIRST FLOOR PLAN - AREA C - FIRE PROTECTION

FP-112-1.1 OVERALL FIRST FLOOR PLAN - AREA B - FIRE PROTECTION

FP-113-1.1 OVERALL FIRST FLOOR PLAN - AREA A - FIRE PROTECTION

FP-121-1A.2 OVERALL SECOND FLOOR PLAN - AREA C - FIRE PROTECTION

FP-123-1.2 OVERALL SECOND FLOOR PLAN - AREA A - FIRE PROTECTION

FP-131-1A.3 OVERALL THIRD FLOOR PLAN - AREA C - FIRE PROTECTION

FP-133-1.3 OVERALL THIRD FLOOR PLAN - AREA A - FIRE PROTECTION

FP-141-1A.4 OVERALL FOURTH FLOOR PLAN - AREA C - FIRE PROTECTION

FP-143-1.4 OVERALL FOURTH FLOOR PLAN - AREA A - FIRE PROTECTION

FP-151-1A.5 OVERALL FIFTH FLOOR PLAN - AREA C - FIRE PROTECTION

FP-153-1.5 OVERALL FIFTH FLOOR PLAN - AREA A - FIRE PROTECTION

FP-163-1.6 OVERALL SIXTH FLOOR PLAN - AREA A - FIRE PROTECTION

FP-400-1-1A.G FIRE PROTECTION ENLARGED PLANS - DEMOLITION & NEW WORK

FP-401-1.G FIRE PROTECTION ENLARGED PLANS - GROUND FLOOR - DEMOLITION & NEW WORK

FP-411-1-1A.3 FIRE PROTECTION ENLARGED PLANS - FIRST FLOOR - DEMOLITION & NEW WORK FP-421-1-1A.2 FIRE PROTECTION ENLARGED PLANS - SECOND FLOOR - DEMOLITION & NEW WORK FP-431-1-1A.3 FIRE PROTECTION ENLARGED PLANS - THIRD FLOOR - DEMOLITION & NEW WORK FP-441-1-1A.4 FIRE PROTECTION ENLARGED PLANS - FOURTH FLOOR - DEMOLITION & NEW WORK FP-451-1-1A.5 FIRE PROTECTION ENLARGED PLANS - FIFTH FLOOR - DEMOLITION & NEW WORK

FP-461-1.6 FIRE PROTECTION ENLARGED PLANS - SIXTH FLOOR - DEMOLITION & NEW WORK

FP-700 FIRE PROTECTION DETAILS

PLUMBING

PL-000 PLUMBING SYMBOLS AND ABBREVIATIONS

PL-100-1A.G OVERALL GROUND FLOOR PLAN - AREA D & PA - PLUMBING

PL-101-1.G OVERALL GROUND FLOOR PLAN - AREA A EAST - PLUMBING

PL-104-1.G OVERALL GROUND FLOOR PLAN - AREA B - PLUMBING

PL-111-1A.1 OVERALL FIRST FLOOR AREA PLAN - AREA C - PLUMBING

PL-112-1.1 OVERALL FIRST FLOOR AREA PLAN - AREA B - PLUMBING

PL-123-1.2 OVERALL SECOND FLOOR PLAN - AREA A - PLUMBING

PL-131-1A.3 OVERALL THIRD FLOOR PLAN - AREA C - PLUMBING

PL-133-1.3 OVERALL THIRD FLOOR PLAN - AREA A - PLUMBING

PL-141-1A.4 OVERALL FOURTH FLOOR PLAN - AREA C - PLUMBING

PL-143-1.4 OVERALL FOURTH FLOOR PLAN - AREA A - PLUMBING

PL-153-1.5 OVERALL FIFTH FLOOR PLAN - AREA A - PLUMBING

PL-163-1.6 OVERALL SIXTH FLOOR PLAN - AREA A - PLUMBING

PL-400A-1-1A.G PLUMBING ENLARGED PLANS - GROUND FLOOR - DEMOLITION & NEW WORK

PL-400B-1-1A.G PLUMBING ENLARGED PLANS - GROUND FLOOR - DEMOLITION & NEW WORK

PL-401-1A.1 PLUMBING ENLARGED PLANS - FIRST FLOOR - DEMOLITION & NEW WORK

PL-402-1.2 PLUMBING ENLARGED PLANS - SECOND FLOOR - DEMOLITION & NEW WORK

PL-403-1-1A.3 PLUMBING ENLARGED PLANS - THIRD FLOOR - DEMOLITION & NEW WORK

PL-404-1-1A.4 PLUMBING ENLARGED PLANS - FOURTH FLOOR - DEMOLITION & NEW WORK

PL-405-1.5 PLUMBING ENLARGED PLANS - FIFTH FLOOR - DEMOLITION & NEW WORK

PL-406-1.6 PLUMBING ENLARGED PLANS - SIXTH FLOOR - DEMOLITION & NEW WORK

MECHANICAL

M-000 MECHANICAL SYMBOLS AND ABBREVIATIONS

M-100-1A.G OVERALL GROUND FLOOR - AREA D - MECHANICAL

M-102-1.G OVERALL GROUND FLOOR - AREA B - MECHANICAL

M-103-1.G OVERALL GROUND FLOOR - AREA A WEST - MECHANICAL

M-104-1.G OVERALL GROUND FLOOR - AREA A EAST - MECHANICAL

M-111-1A.1 OVERALL FIRST FLOOR - AREA C - MECHANICAL

M-112-1.1 OVERALL FIRST FLOOR - AREA B - MECHANICAL

M-113-1.1 OVERALL FIRST FLOOR - AREA A WEST - MECHANICAL

M-121-1A.2 OVERALL SECOND FLOOR - AREA C - MECHANICAL

M-123-1.2 OVERALL SECOND FLOOR - AREA A - MECHANICAL

M-131-1A.3 OVERALL THIRD FLOOR - AREA C - MECHANICAL

M-133-1.3 OVERALL THIRD FLOOR - AREA A - MECHANICAL

M-141-1A.4 OVERALL FOURTH FLOOR - AREA C - MECHANICAL

M-143-1.4 OVERALL FOURTH FLOOR - AREA A - MECHANICAL

M-151-1A.5 OVERALL FIFTH FLOOR - AREA C - MECHANICAL

M-153-1.5 OVERALL FIFTH FLOOR - AREA A - MECHANICAL

M-163-1.6 OVERALL SIXTH FLOOR - AREA A - MECHANICAL

M-400A-1A.G BUILDING 1A - ENLARGED PLANS - GROUND FLOOR - MECHANICAL

M-400B-1A.G BUILDING 1A - ENLARGED PLANS - GROUND FLOOR - MECHANICAL

M-402-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - MECHANICAL

M-403A-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - MECHANICAL

M-403B-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - MECHANICAL

M-404A-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - MECHANICAL

M-404B-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - MECHANICAL

M-411-1A.1 BUILDING 1A - ENLARGED PLANS - FIRST FLOOR - MECHANICAL

M-412-1.1 BUILDING 1 - ENLARGED PLANS - FIRST FLOOR - MECHANICAL

M-413-1.1 BUILDING 1 - ENLARGED PLANS - FIRST FLOOR - MECHANICAL

M-414-1.1 BUILDING 1 - ENLARGED PLANS - YARD - MECHANICAL

M-421-1A.2 BUILDING 1A - ENLARGED PLANS - SECOND FLOOR - MECHANICAL

M-423-1.2 BUILDING 1 - ENLARGED PLANS - SECOND FLOOR - MECHANICAL

M-431-1A.3 BUILDING 1A - ENLARGED PLANS - THIRD FLOOR - MECHANICAL

M-433-1.3 BUILDING 1 - ENLARGED PLANS - THIRD FLOOR - MECHANICAL

M-441-1A.4 BUILDING 1A - ENLARGED PLANS - FOURTH FLOOR - MECHANICAL

M-443-1.4 BUILDING 1 - ENLARGED PLANS - FOURTH FLOOR - MECHANICAL

M-451-1A.5 BUILDING 1A - ENLARGED PLANS - FIFTH FLOOR & ROOF - MECHANICAL

M-453-1.5 BUILDING 1 - ENLARGED PLANS - FIFTH FLOOR - MECHANICAL

M-463-1.6 BUILDING 1 - ENLARGED PLANS - SIXTH FLOOR & ROOF - MECHANICAL

M-501 MECHANICAL DETAILS AND SCHEDULES

M-701 MECHANICAL CONTROLS

ELECTRICAL

E-000 ELECTRICAL SYMBOLS AND ABBREVIATIONS

E-010 BUILDING 1A PICTURE REFERENCES PAGE 1

E-011 BUILDING 1A PICTURE REFERENCES PAGE 2

E-012 BUILDING 1 PICTURE REFERENCES PAGE 1

E-013 BUILDING 1 PICTURE REFERENCES PAGE 2

E-014 POWER SOURCE AND UPS FEEDERS PICTURE REFERENCES

E-015 CRAWL SPACE AND OTHER PICTURE REFERENCES

E-016 MECH ROOM, CRAWL SPACE ACCESS, AND BLDG 1A PARKING GARAGE CEILING

PICTURE REFERENCES

E-100 OVERALL GROUND FLOOR REFERENCE PLAN - ELECTRICAL

E-100-1A.G OVERALL GROUND FLOOR PLAN - AREA D & PA - ELECTRICAL

E-101-1A.G OVERALL GROUND FLOOR PLAN - AREA PA - ELECTRICAL

E-102-1.G OVERALL GROUND FLOOR PLAN - AREA B - ELECTRICAL

E-103-1.G OVERALL GROUND FLOOR PLAN - AREA A - ELECTRICAL

E-111-1A.1 OVERALL FIRST FLOOR PLAN - AREA C - ELECTRICAL

E-112-1.1 OVERALL FIRST FLOOR PLAN - AREA B - ELECTRICAL

E-113-1.1 OVERALL FIRST FLOOR PLAN - AREA A - ELECTRICAL

E-121-1A.2 OVERALL SECOND FLOOR PLAN - AREA C - ELECTRICAL

E-123-1.2 OVERALL SECOND FLOOR PLAN - AREA A - ELECTRICAL

E-131-1A.3 OVERALL THIRD FLOOR PLAN - AREA C - ELECTRICAL

E-133-1.3 OVERALL THIRD FLOOR PLAN - AREA A - ELECTRICAL

E-141-1A.4 OVERALL FOURTH FLOOR PLAN - AREA C - ELECTRICAL

E-143-1.4 OVERALL FOURTH FLOOR PLAN - AREA A - ELECTRICAL

E-151-1A.5 OVERALL FIFTH FLOOR PLAN - AREA C - ELECTRICAL

E-153-1.5 OVERALL FIFTH FLOOR PLAN - AREA A - ELECTRICAL

E-161-1.6 OVERALL SIXTH FLOOR PLAN - AREA A - ELECTRICAL

E-171-1A.R OVERALL ROOF PLAN - BUILDING 1A - ELECTRICAL

E-173-1.R OVERALL ROOF PLAN - BUILDING 1 - ELECTRICAL

E-400A-1A.G BUILDING 1A - ENLARGED PLANS - GROUND FLOOR - MAIN ELECTRICAL ROOMS

E-400B-1A.G BUILDING 1A - ENLARGED PLANS - GROUND FLOOR - NEW ELECTRICAL ROOMS

E-400C-1A.G BUILDING 1A - ENLARGED PLANS - GROUND FLOOR - TR D007D

E-403A-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - MAIN ELECTRICAL ROOMS

E-403B-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - NEW ELECTRICAL ROOMS

E-403C-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - ELECTRICAL - TR A002C

E-403D-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - ELECTRICAL - DATA CENTER A073

DEMO

E-403E-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - ELECTRICAL - DATA CENTER A073

POWER & LTG

E-403F-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - CRAWL SPACE

E-403G-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - ELECTRICAL - A056

E-403H-1.G BUILDING 1 - ENLARGED PLANS - GROUND FLOOR - ELECTRICAL - B046

E-411-1A.1 BUILDING 1A - ENLARGED PLANS - FIRST FLOOR - ELECTRICAL - TR C121

E-412-1.1 BUILDING 1 - ENLARGED PLANS - FIRST FLOOR - ELECTRICAL - B125

E-413-1.1 BUILDING 1 - ENLARGED PLANS - FIRST FLOOR - ELECTRICAL - TR A104

E-421-1A.2 BUILDING 1A - ENLARGED PLANS - SECOND FLOOR - ELECTRICAL - TR C222

E-423-1.2 BUILDING 1 - ENLARGED PLANS - SECOND FLOOR - ELECTRICAL - TR A243

E-431-1A.3 BUILDING 1A - ENLARGED PLANS - THIRD FLOOR - ELECTRICAL - TR CU333

E-433-1.3 BUILDING 1 - ENLARGED PLANS - THIRD FLOOR - ELECTRICAL - TR A345

E-441-1A.4 BUILDING 1A - ENLARGED PLANS - FOURTH FLOOR - ELECTRICAL - TR CU411

E-443-1.4 BUILDING 1 - ENLARGED PLANS - FOURTH FLOOR - ELECTRICAL - TR A450

ELECTRICAL (CONTINUED)

E-451-1.5 BUILDING 1 - ENLARGED PLANS - FIFTH FLOOR - ELECTRICAL - TR AU547

E-453-1A.5 BUILDING 1A - ENLARGED PLANS - FIFTH FLOOR - ELECTRICAL - TR C580

E-461-1.6 BUILDING 1 - ENLARGED PLANS - SIXTH FLOOR - ELECTRICAL - TR A627

E-501 ELECTRICAL EQUIPMENT DATA SCHEDULE

E-502 ELECTRICAL FEEDER AND LIGHTING SCHEDULES

E-601-1A BUILDING 1A - ELECTRICAL ONE-LINE

E-602-1 BUILDING 1 - ELECTRICAL ONE-LINE

E-603 ELECTRICAL PANEL SCHEDULES PAGE 1

E-604 ELECTRICAL PANEL SCHEDULES PAGE 2

E-605 ELECTRICAL PANEL SCHEDULES PAGE 3

E-606 ELECTRICAL PANEL SCHEDULES PAGE 4

E-607 ELECTRICAL DETAILS PAGE 1

E-608 ELECTRICAL DETAILS PAGE 2

E-609 ELECTRICAL GROUNDING ELEVATIONS

TECHNOLOGY

T-001 TECHNOLOGY GENERAL INFORMATION

T-002 TECHNOLOGY SCHEDULES

TD-100-1A.G DEMO PLAN - BLDG. 1A PARKING GARAGE - LEVEL A

TD-101-1A.G DEMO PLAN - BLDG. 1A PARKING GARAGE - LEVEL A

TD-102-1A.G DEMO PLAN - BLDG. 1A PARKING GARAGE - LEVEL B

TD-103-1A.G DEMO PLAN - BLDG. 1A PARKING GARAGE - LEVEL B

TD-104-1A.G DEMO PLAN - BLDG. 1A PARKING GARAGE - LEVEL C

TD-105-1A.G DEMO PLAN - BLDG. 1A PARKING GARAGE - LEVEL C

TD-107-1.G DEMO PLAN - BLDG. 1 GROUND FLOOR - AREA A

TD-108-1.G DEMO PLAN - BLDG. 1 GROUND FLOOR - AREA B

TD-110-1.1 DEMO PLAN - BLDG. 1 FIRST FLOOR - AREA A

TD-111-1.1 DEMO PLAN - BLDG. 1 FIRST FLOOR - AREA B

TD-114-1A.1 DEMO PLAN - BLDG. 1A FIRST FLOOR - AREA C

TD-115-1A.1 DEMO PLAN - BLDG. 1A FIRST FLOOR - AREAS D & E

TD-120-1.2 DEMO PLAN - BLDG. 1 SECOND FLOOR - AREA A

TD-121-1.2 DEMO PLAN - BLDG. 1 SECOND FLOOR - AREA B

TD-123-1A.2 DEMO PLAN - BLDG. 1A SECOND FLOOR - AREA C

TD-124-1A.2 DEMO PLAN - BLDG. 1A SECOND FLOOR - AREA D

TD-130-1.3 DEMO PLAN - BLDG. 1 THIRD FLOOR - AREA A

TD-131-1.3 DEMO PLAN - BLDG. 1 THIRD FLOOR - AREA B

TD-133-1A.3 DEMO PLAN - BLDG. 1A THIRD FLOOR - AREA C

TD-134-1A.3 DEMO PLAN - BLDG. 1A THIRD FLOOR - AREA D

TD-140-1.4 DEMO PLAN - BLDG. 1 FOURTH FLOOR - AREA A

TD-141-1.4 DEMO PLAN - BLDG. 1 FOURTH FLOOR - AREA B

TD-143-1A.4 DEMO PLAN - BLDG. 1A FOURTH FLOOR - AREA C

TD-144-1A.4 DEMO PLAN - BLDG. 1A FOURTH FLOOR - AREA D

TD-150-1.5 DEMO PLAN - BLDG. 1 FIFTH FLOOR - AREA A

TD-151-1.5 DEMO PLAN - BLDG. 1 FIFTH FLOOR - AREA B

TD-153-1A.5 DEMO PLAN - BLDG. 1A FIFTH FLOOR - AREA C

TD-154-1A.5 DEMO PLAN - BLDG. 1A FIFTH FLOOR - AREA C

TD-160-1.6 DEMO PLAN - BLDG. 1 SIXTH FLOOR - AREA A

TD-161-1.6 DEMO PLAN - BLDG. 1 SIXTH FLOOR - AREA B

TD-400-1-1A.G BLDGS. 1 & 1A - GROUND FL. TR DEMO PLAN

TD-403-1-1A.1 BLDGS. 1 & 1A - FIRST FLOOR TR DEMO PLAN

TD-406-1-1A.2 BLDGS. 1 & 1A - SECOND FL. TR DEMO PLAN

TD-409-1-1A.3 BLDGS. 1 & 1A - THIRD FLOOR TR DEMO PLAN

TD-412-1-1A.4 BLDGS. 1 & 1A - FOURTH FL. TR DEMO PLAN

TD-415-1-1A.5 BLDGS. 1 & 1A - FIFTH FLOOR TR DEMO PLAN

TD-418-1-1A.6 BLDGS. 1 & 1A - SIXTH FLOOR TR DEMO PLAN

TN-200-1A.G FLOOR PLAN - BLDG. 1A PARKING GARAGE - AREA D

TN-201-1A.G FLOOR PLAN - BLDG. 1A PARKING GARAGE - AREA PA

TN-202-1A.G FLOOR PLAN - BLDG. 1A PARKING GARAGE - LEVEL B

TN-203-1A.G FLOOR PLAN - BLDG. 1A PARKING GARAGE - LEVEL B

TN-204-1A.G FLOOR PLAN - BLDG. 1A PARKING GARAGE - LEVEL C

TN-205-1A.G FLOOR PLAN - BLDG. 1A PARKING GARAGE - LEVEL C

TN-207-1.G FLOOR PLAN - BLDG. 1 GROUND FLOOR - AREA A

TN-208-1.G FLOOR PLAN - BLDG. 1 GROUND FLOOR - AREA B

TN-210-1.1 FLOOR PLAN - BLDG. 1 FIRST FLOOR - AREA A

TN-211-1.1 FLOOR PLAN - BLDG. 1 FIRST FLOOR - AREA B

TN-214-1A.1 FLOOR PLAN - BLDG. 1A FIRST FLOOR - AREA C

TN-215-1A.1 FLOOR PLAN - BLDG. 1A FIRST FLOOR - AREAS D & E

TN-220-1.2 FLOOR PLAN - BLDG. 1 SECOND FLOOR - AREA A

TN-221-1.2 FLOOR PLAN - BLDG. 1 SECOND FLOOR - AREA B

TN-223-1A.1 FLOOR PLAN - BLDG. 1A SECOND FLOOR - AREA C

TN-224-1A.2 FLOOR PLAN - BLDG. 1A SECOND FLOOR - AREA D

TN-230-1.3 FLOOR PLAN - BLDG. 1 THIRD FLOOR - AREA A

TN-231-1.3 FLOOR PLAN - BLDG. 1 THIRD FLOOR - AREA B

TN-233-1A.3 FLOOR PLAN - BLDG. 1A THIRD FLOOR - AREA C

TN-234-1A.3 FLOOR PLAN - BLDG. 1A THIRD FLOOR - AREA D

TN-240-1.4 FLOOR PLAN - BLDG. 1 FOURTH FLOOR - AREA A

TN-241-1.4 FLOOR PLAN - BLDG. 1 FOURTH FLOOR - AREA B

TN-243-1A.4 FLOOR PLAN - BLDG. 1A FOURTH FLOOR - AREA C

TN-244-1A.4 FLOOR PLAN - BLDG. 1A FOURTH FLOOR - AREA D

TN-250-1.5 FLOOR PLAN - BLDG. 1 FIFTH FLOOR - AREA A

TN-251-1.5 FLOOR PLAN - BLDG. 1 FIFTH FLOOR - AREA B

TN-253-1A.5 FLOOR PLAN - BLDG. 1A FIFTH FLOOR - AREA C

TN-254-1A.5 FLOOR PLAN - BLDG. 1A FIFTH FLOOR - AREA C

TN-260-1.6 FLOOR PLAN - BLDG. 1 SIXTH FLOOR - AREA A

TN-261-1.6 FLOOR PLAN - BLDG. 1 - SIXTH FLOOR - AREA B

TN-300-1-1A.G FLOOR PLAN - PATHWAY GROUND FLOOR

TN-301-1-1A.1 FLOOR PLAN - PATHWAY FIRST FLOOR

TN-302-1-1A.2 FLOOR PLAN - PATHWAY SECOND FLOOR

TN-303-1-1A.3 FLOOR PLAN - PATHWAY THIRD FLOOR

TN-304-1-1A.4 FLOOR PLAN - PATHWAY FOURTH FLOOR

TN-305-1-1A.5 FLOOR PLAN - PATHWAY FIFTH FLOOR

TN-306-1.6 FLOOR PLAN - PATHWAY SIXTH FLOOR

TN-310-1-1A.G FLOOR PLAN - PATHWAY FIBER OPTIC - GROUND FLOOR

TN-311-1-1A.1 FLOOR PLAN - PATHWAY FIBER OPTIC - FIRST FLOOR

TN-312-1-1A.2 FLOOR PLAN - PATHWAY FIBER OPTIC - SECOND FLOOR

TN-313-1-1A.3 FLOOR PLAN - PATHWAY FIBER OPTIC - THIRD FLOOR

TN-314-1-1A.4 FLOOR PLAN - PATHWAY FIBER OPTIC - FOURTH FLOOR

TN-315-1-1A.5 FLOOR PLAN - PATHWAY FIBER OPTIC - FIFTH FLOOR

TN-316-1.6 FLOOR PLAN - PATHWAY FIBER OPTIC - SIXTH FLOOR

TN-400-1-1A.G TR ZONES - BLDGS. 1 & 1A GROUND FLOOR

TN-401-1.G TR LAYOUT - ROOM A002C GROUND FLOOR

TN-402-1A.1 TR LAYOUT - ROOM D007D GROUND FLOOR

TN-403-1-1A.1 TR ZONES - BLDGS. 1 & 1A FIRST FLOOR

TN-404-1.1 TR LAYOUT - ROOM A104 FIRST FLOOR

TN-405-1A.1 TR LAYOUT - ROOM C121 FIRST FLOOR

TN-406-1-1A.2 TR ZONES - BLDGS. 1 & 1A SECOND FLOOR

TN-407-1.2 TR LAYOUT - ROOM A243 SECOND FLOOR

TN-408-1A.2 TR LAYOUT - ROOM C222 SECOND FLOOR

TN-409-1-1A.3 TR ZONES - BLDGS. 1 & 1A THIRD FLOOR

TN-410-1.3 TR LAYOUT - ROOM A345 THIRD FLOOR

TN-411-1A.3 TR LAYOUT - ROOM CU333 THIRD FLOOR

TN-412-1-1A.4 TR ZONES - BLDGS. 1 & 1A FOURTH FLOOR

TN-413-1.4 TR LAYOUT - ROOM A450 FOURTH FLOOR

TECHNOLOGY (CONTINUED)

TN-414-1A.4 TR LAYOUT - ROOM CU411 FOURTH FLOOR

TN-415-1-1A.5 TR ZONES - BLDGS. 1 & 1A FIFTH FLOOR

TN-416-1.5 TR LAYOUT - ROOM AU547 FIFTH FLOOR

TN-417-1A.5 TR LAYOUT - ROOM C580 FIFTH FLOOR

TN-418-1-1A.6 TR ZONES - BLDGS 1 & 1A SIXTH FLOOR

TN-419-1.6 TR LAYOUT - ROOM A627 SIXTH FLOOR

TN-420-1.G TR LAYOUT - ROOM B046A GROUND FLOOR

TN-421-1.1 TR LAYOUT - ROOM B125 FIRST FLOOR

TN-450-1A.G BLDG. 1A - DATA CENTER TECHNOLOGY EXISTING PLAN

TN-451-1A.G BLDG. 1A - DATA CENTER TECHNOLOGY PLAN

TN-452-1A.G BLDG. 1A - DATA CENTER CABLE PATHWAYS PLAN

TN-453-1A.G BLDG. 1A - DATA CENTER ELEVATIONS AND DETAILS

TN-454-1A.G MCR STRUCTURED CABLING PLAN

TN-455-1A.G POWER ELEVATION AND SCHEMATIC - LEVEL REDUNDANCY

TN-500 TECHNOLOGY - TYPICAL DETAILS

TN-501 TECHNOLOGY - TYPICAL DETAILS

TN-502 GROUNDING & BONDING TYPICAL DETAILS

TN-600 FIBER OPTIC CABLE RISER DIAGRAM

TN-601 BONDING AND GROUNDING RISER DIAGRAM

SECURITY

S-000 SECURITY COVER PAGE

S-010 SECURITY SYSTEMS LEGEND

S-100 OVERALL GROUND FLOOR REFERENCE PLAN - SECURITY

S-110 OVERALL FIRST FLOOR REFERENCE PLAN - SECURITY

S-120 OVERALL SECOND FLOOR REFERENCE PLAN - SECURITY

S-130 OVERALL THIRD FLOOR REFERENCE PLAN - SECURITY

S-140 OVERALL FOURTH FLOOR REFERENCE PLAN - SECURITY

S-150 OVERALL FIFTH FLOOR REFERENCE PLAN - SECURITY

S-160 OVERALL SIXTH FLOOR REFERENCE PLAN - SECURITY

S-400 ENLARGED GROUND FLOOR PLANS - SECURITY

S-401 ENLARGED GROUND FLOOR PLANS - SECURITY

S-410 ENLARGED FIRST FLOOR PLANS - SECURITY

S-420 ENLARGED SECOND FLOOR PLANS - SECURITY

S-430 ENLARGED THIRD FLOOR PLANS - SECURITY

S-440 ENLARGED FOURTH FLOOR PLANS - SECURITY

S-450 ENLARGED FIFTH FLOOR PLANS - SECURITY

S-460 ENLARGED SIXTH FLOOR PLANS - SECURITY

S-500 SECURITY - TYPICAL DETAILS

S-501 SECURITY - TYPICAL DETAILS

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

ARCHITECT OF RECORDCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

569A4-22-700

5/16/23

100% CONSTRUCTION

DOCUMENTS

LEXINGTON-COOPER EHRM

INFRASTRUCTURE DESIGN

1101 VETERANS DRIVE

LEXINGTON, KY 40502

GI-010

INDEX OF DRAWINGS

RAC

5/16/23

DISCIPLINE REFERENCES

DRAWING FOR THE FOLLOWING DISCIPLINES ARE

CONTAINED IN THE DOCUMENT. THE DISCIPLINES ARE

IDENTIFIED BY THE REFERENCE WHICH IS INCORPORATED

INTO THE SHEET TITLE.

G GENERAL INFORMATION

H HAZARDOUS

V SURVEY/MAPPING

B GEOTECHNICAL

W CIVIL WORKS

C CIVIL

L LANDSCAPE

S STRUCTURAL

A ARCHITECTURAL

I INTERIORS

Q EQUIPMENT

F FIRE PROTECTION

P PLUMBING

D PROCESS

M MECHANICAL

E ELECTRICAL

T TELECOMM

SHEET NUMBER

AD-100-1.B

DISCIPLINE

SHEET NUMBER

BUILDING

FLOOR

BUILDING

NUMBER

DRAWING NUMBERING

1 BUILDING SECTION

SCALE: 1/8" = 1'-0"

EACH DRAWING IS NUMBERED ACCORDING TO IT'S

LOCATION ON THE SHEET. THE DRAWING TITLE APPEARS

ABOVE THE DEMARCATION LINE AND THE APPROPRIATE

SCALE IS LOCATED BELOW THE DEMARCATION LINE.

DRAWING REFERENCE

1/AS-101

SHEET NUMBERDRAWING NUMBER

ON SHEET BY

LOCATION

ARCHITECTURAL SYMBOLS

℄ CENTER LINE

ELEVATION INDICATORXXX.XX'

CENTER LINE INDICATOR

DEMOLITION LINE

EXISTING TO REMAIN LINE

FEATURES ABOVE LINE INDICATOR

CONSTRUCTION LIMITS

BREAK, ROUND (USER DEFINES SIZE)

BREAK, STRAIGHT (SEE SECTION

INDICATORS, BUILDING BREAK

STANDARDS)

DIMENSION LINE

X'-X"

1/AS-101 INTERIOR ELEVATION

P-1

WALL OR PARTITION TYPE

ROOM NAME

ROOM NAME

ROOM NAME AND NUMBER

A

COLUMN GRID

22 KEYED NOTE

N

NORTH ARROW

REVISIONS

EXTENT OF

CURRENT

REVISION

REVISION

NUMBER

REFER TO REVISION HISTORY ON TITLE BLOCK OF EACH

SHEET.

1/AS-101

DETAIL INDICATOR

1/AS-101 BUILDING SECTION INDICATOR

101 DOOR NUMBER

A WINDOW INDICATOR

GENERAL NOTES

1. UNLESS NOTED AS EXISTING, ALL MATERIALS, EQUIPMENT,

MANUFACTURED ITEMS AND ASSEMBLIES INCORPORATED

INTO THE WORK SHALL BE NEW.

2. UNLESS NOTED TO BE REMOVED AND DISPOSED, ALL

EXISTING ITEMS ARE TO REMAIN. THEY SHALL BE

PROTECTED FROM DAMAGE DUE TO CONSTRUCTION

ACTIVITIES. ANY EXISTING ITEMS TO REMAIN THAT

BECOME DAMAGED DUE TO CONSTRUCTION ACTIVITIES

SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING

AT NO ADDITIONAL COST TO THE OWNER.

3. NOTATIONS FOR ITEMS OF WORK APPLY TO EACH

GRAPHICAL INDICATION SHOWN ON THE DRAWINGS,

WHETHER OR NOT NOTED.

4. ALL ITEMS NOTED TO HAVE PAINT FINISH SHALL BE

CLEANED AND PREPARED IN ACCORDANCE WITH THE

SPECIFICATIONS PRIOR TO THE APPLICATION OF PRIMER

AND PAINT.

5. THE CONTRACTOR SHALL FAMILIARIZE THEMSELF WITH

THE ARCHITECTURAL, STRUCTURAL, MECHANICAL,

ELECTRICAL, PLUMBING, TECHNOLOGY, ETC. WORK

SCOPE AND SATISFY THAT ALL REQUIREMENTS FOR

SUPPORT, FLOOR, WALL AND ROOF OPENINGS, FLASHINGS

AND CURBS, ETC. ARE IMPLEMENTED. THE COR SHALL BE

NOTIFIED OF CONFLICTS OR DISCREPANCIES PRIOR TO

COMMENCEMENT OF CONSTRUCTION.

6. CONTRACTOR TO REPLACE AND ACCURATELY LOCATE

ALL EXISTING SIGNAGE AND LABELS NOTING RATED WALL

ASSEMBLIES AND SMOKE PARTITIONS.

7. THE CONTRACTOR SHALL VISIT THE SITE, VERIFY FIELD

CONDITIONS AND COMPARE SUCH FIELD CONDITIONS AND

OTHER INFORMATION KNOWN TO THE CONTRACTOR WITH

CONTRACT DOCUMENTS.

8. THE CONTRACTOR SHALL REPORT ANY UNFORESEEN

FIELD CONDITIONS, ERRORS, INCONSISTENCIES, OR

OMISSIONS DISCOVERED AT ANY TIME DURING THE WORK.

UPON SUCH DISCOVERY, THE CONTRACTOR SHALL

CONTACT THE CONTRACT OFFICER FOR CLARIFICATION

BEFORE PROCEEDING OR CONTINUING WITH THAT

PORTION OF THE WORK OR ANY PORTION RELATED THERE

TO.

9. ALL WORK SHALL CONFORM TO MOST CURRENT VERSION

OF APPLICABLE CODES AND STANDARDS INCLUDING THE

INTERNATIONAL BUILDING CODE, VA MASTER

SPECIFICATIONS, AND LATEST ADOPTED NFPA.

10. THE CONTRACTOR SHALL NOTIFY THE CONTRACT

OFFICER, CONTRACTING OFFICER'S REPRESENTATIVE, OF

ANY DISCREPANCIES BETWEEN THE DRAWINGS, NOTES,

AND ACTUAL FIELD CONDITIONS BEFORE BIDDING AND

COMMENCING ANY WORK, AND REQUEST CLARIFICATION

IN WRITING.

11. WHEN UNANTICIPATED ARCHITECTURAL, STRUCTURAL,

MECHANICAL, ELECTRICAL, PLUMBING, TECHNOLOGY, ETC.

ELEMENTS CONFLICTING WITH THE INTENDED FUNCTION

OR DESIGN ARE ENCOUNTERED, INVESTIGATE AND

MEASURE THE CONFLICTS NATURE AND EXTENT. SUBMIT

A WRITTEN REPORT TO THE CONTRACT OFFICER.

12. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, INSTALL

COMPONENTS USING MANUFACTURER'S OR INDUSTRY

STANDARDS. WHERE STANDARDS DO NOT EXIST, NOTIFY

THE COR FOR CLARIFICATION.

13. CONTRACTOR SHALL NOT BARRICADE/BARRIER

EMERGENCY EGRESS TO OR FROM THIS AREA.

CONTRACTOR SHALL MAINTAIN EXIT TO EXTERIOR DURING

THE WORK PROGRESS.

14. PROVIDE ACCESS TO THE WORK AS DIRECTED BY THE

CONTRACTING OFFICER REPRESENTATIVE. SECURE

ACCESS POINT AS SPECIFIED AND DIRECTED BY THE

CONTRACTING OFFICER REPRESENTATIVE PROJECT

ENGINEER. PROVIDE WALK-OFF MATS TO MEET FACILITY

INFECTION CONTROL GUIDELINES AT EACH REQUIRED

ACCESS POINT.

15. ALL EXISTING WALL MOUNTED ITEMS AND DEVICES ARE

TO BE REMOVED PRIOR TO DEMOLITION WORK, FULLY

REFURBISHED, AND REINSTALLED IN THE NEW WALL

ASSEMBLY. LOCATION TO BE VERIFIED BY CONTRACTING

OFFICER REPRESENTATIVE. ITEMS MAY INCLUDE: DOOR

STOPS, HAND SANITIZER DISPENSERS, FIRE STROBES,

SWITCHES, ELECTRIC COVER PLATES, FIRE ALARM PULL

BOXES, ELECTRIC OUTLETS, SIGNAGE, BULLETIN BOARDS,

MILLWORK, CARD READERS, CLOCK, DATA OUTLET, PUSH

BUTTON, FIRE CONTROL BOX, PHONE, ETC.

16. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR

LEGAL DISPOSAL OF ALL DEBRIS.

17. OWNER SHALL HAVE THE RIGHT OF FIRST REFUSAL ON

ITEMS INDICATED TO BE SALVAGED.

18. EXISTING SPRAYED-ON FIREPROOFING SHALL BE

MAINTAINED THROUGH THE DURATION OF CONSTRUCTION

ACTIVITIES AND THE CONTRACTOR SHALL REPAIR ANY

COMPROMISE OF EXISTING FIREPROOFING.

19. BUILDINGS WILL BE OCCUPIED AT ALL TIMES THROUGH

THE DURATION OF CONSTRUCTION.

DIMENSIONING CONVENTIONS

1. EXCEPT WHERE DIRECTED TO PLACE WORK ITEMS AT THE

"APPROXIMATE LOCATION SHOWN." DO NOT SCALE

DRAWINGS FOR DIMENSIONAL INFORMATION.

2. ALL ELEMENTS OF THE DOCUMENTS MAY NOT BE DRAWN

TO EXACT SCALE. DIMENSIONS REQUESTED ARE SHOWN

(OR DERIVED FROM THOSE SHOWN OR NOTED) ON FLOOR

PLANS, DETAIL PLANS, ELEVATIONS, SECTIONS,

SCHEDULES, CONFIGURATION DETAILS, AND

SPECIFICATIONS. SEE THE NOTES BELOW AND SYMBOLS

FOR DIMENSIONING CONVENTIONS.

3. EXCEPT WHERE SPECIFICALLY NOTED TO THE CONTRARY,

ALL DIMENSIONS SHOWN ON THE ARCHITECTURAL

DRAWINGS CONFORM TO THE FOLLOWING CONVENTIONS.

A. MEASURED FROM FACE OF PARTITION ASSEMBLY:

• FACE OF PARTITION ASSEMBLY (EXCLUSIVE OF

APPLIED FINISHES HAVING THICKNESS WHICH MAY BE

ADDED TO SUCH WALL AS DEFINED BY THE PARTITION

SCHEDULE. UNLESS NOTED AS "FACE OF FINISH" OR

"CLEAR" DIMENSION, DIMENSIONS ARE NOT

MEASURED TO THE FACE OF APPLIED FINISH BUT

RATHER TO THE FACE OF CORE STRUCTURE (STUD,

CMU, ETC.). REFER TO EACH PARTITION TYPES

THICKNESS.

B. DIMENSIONS UTILIZING "CENTERLINE" SYMBOL ARE

MEASURED TO:

• CENTERLINE OF PARTITION ASSEMBLY (EXCLUSIVE OF

ANY APPLIED FINISHES HAVING THICKNESS WHICH

MAY BE ADDED TO SUCH WALLS) AT PARTITIONS

FRAMED WITH METAL STUDS. REFER TO "PARTITION

SCHEDULE" TO DETERMINE EACH PARTITION TYPES

THICKNESS.

• CENTERLINE OF DOOR, WINDOW, OR LOUVER

OPENING.

• CENTERLINE OF OTHER FEATURES AS INDICATED.

C. WHERE "EQUAL" DIMENSIONS USED ON REFLECTED

CEILING PLANS TO LOCATE CEILING GRID WORK

POINTS, MEASURE DIMENSIONS TO:

• EDGE OF INDICATED CEILING AT THE FACE OF THE

ADJACENT APPLIED FINISH MEASURED AT THE

CEILING PLANE.

• CAUTION: DUE TO THE POSSIBLE APPLICATION OF

APPLIED FINISHES - THICKNESS WHICH MAY VARY

BETWEEN FLOOR AND CEILING AND NOT ACCOUNTED

FOR (EXCEPT AS INDICATED BY "FACE OF FINISH" OR

"CLEAR") BY THE DIMENSION SHOWN ON FLOOR PLANS -

THE CONTRACTOR MUST ADJUST THE FLOOR PLAN

DIMENSIONS TO REFLECT ACTUAL DIMENSIONS FOUND

AT THE CEILING PLANE.

4. WHERE WALLS AND/OR PARTITIONS OF UNEQUAL

THICKNESS ABUT, ALIGN EXPOSED FACES, UNLESS

OTHERWISE NOTED.

ALIGN

DIMENSION,

WHEN OCCURS

5. WHERE OPENINGS IN WALLS (INTERIOR WINDOWS OR

DOORS) ARE NOT DIMENSIONED BUT SHOWN AS BEING

CENTERED IN A GIVEN WALL SURFACE. LOCATE OPENINGS

AS GRAPHICALLY REPRESENTED.

MATERIAL GRAPHICS

CONCRETE

EARTH

BASE COURSE

BATT INSULATION

RIGID INSULATION

PROJECT INFORMATION

LOCATION MAP

N

PHASING PLAN

CODES:

2018 IBC OR LATER VERSION

OCCUPANCY:

GROUP 'I-2', CONDITION 2

TYPE OF CONSTRUCTION:

TYPE II-B

PROJECT AREAS (1 & 1A OVERALL):

GROUND FLOOR

FIRST FLOOR

SECOND FLOOR

THIRD FLOOR

FOURTH FLOOR

FIFTH FLOOR

SIXTH FLOOR

DESIGN MANUALS:

- PG-18-1 MASTER CONSTRUCTION SPECIFICATIONS

- PG-18-3 DESIGN AND CONSTRUCTION PROCEDURES

- PG-18-5 EQUIPMENT LIST GUIDES

- PG-18-8 SEISMIC DESIGN HANDBOOK

- PG-10-10 DESIGN MANUALS

- VA ARCHITECTURAL DESIGN MANUAL

- VA MECHANICAL DESIGN MANUAL

- VA ELECTRICAL DESIGN MANUAL

- VA PLUMBING DESIGN MANUAL

- VA FIRE PROTECTION DESIGN MANUAL

APPLICABLE CODES AND REGULATIONS:

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL CURRENT APPLICABLE

CODES AND STANDARDS.

IN ADDITION TO DEPARTMENT OF VETERANS AFFAIRS, ALL WORK SHALL COMPLY

WITH THE DEPARTMENT OF VETERANS AFFAIRS GUIDELINES, ABA (ARCHITECTURAL

BARRIERS ACT) ACCESSIBILITY STANDARD FOR FEDERAL FACILITIES.

APPLICABLE CODES AND STANDARDS (LATEST EDITIONS) INCLUDE:

- ADA ACCESSIBILITY STANDARDS

- NFPA 101, "LIFE SAFETY CODE"

- NFPA 10, "PORTABLE FIRE EXTINGUISHERS"

- NFPA 13, "INSTALLATION OF SPRINKLER SYSTEMS"

- NFPA 70, "NATIONAL ELECTRICAL CODE (NEC)"

- NFPA 72, "NATIONAL FIRE ALARM CODE"

- NFPA 90A, "INSTALLATION OF AIR CONDITIONING AND VENTILATION

SYSTEMS"

- NFPA 99, "INSTALLATION FOR HEALTH CARE FACILITIES"

- NFPA 220, "TYPES OF BUILDING CONSTRUCTION"

- NFPA 241, "STANDARD FOR SAFEGUARDING CONSTRUCTION,

ALTERNATION, AND DEMOLITION OPERATIONS"

- INTERNATIONAL BUILDING CODE (IBC)

- INTERNATIONAL MECHANICAL CODE (IMC)

- INTERNATIONAL PLUMBING CODE (IPC)

- INTERNATIONAL ENERGY CONSERVATION CODE

PHASING PLAN OVERVIEW

TYPICAL ROOM CONSTRUCTION SEQUENCE

PHASING PLAN SEQUENCE

GI-020

GENERAL INFORMATION,

SYMBOLS, & LOCATION MAP

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

ARCHITECT OF RECORDCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

569A4-22-700

5/16/23

100% CONSTRUCTION

DOCUMENTS

LEXINGTON-COOPER EHRM

INFRASTRUCTURE DESIGN

1101 VETERANS DRIVE

LEXINGTON, KY 40502

5/16/23 JY

P1 PHOTO (EXISTING CONDITION)

A LABEL CLASS A DOOR

A/C AIR CONDITION

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAMA AMERICAN ARCHITECTURAL

MANUFACTURERS ASSOCIATION

AB ANCHOR BOLT

ABC AGGREGATE BASE COURSE

AC ASBESTOS CEMENT OR

ASPHALTIC CONCRETE

ACI AMERICAN CONCRETE INSTITUTE

ACM ASBESTOS CONTAINING

MATERIAL

ACP ACRYLIC GLAZING

ACS DR ACCESS DOOR

ACS FLR ACCESS FLOOR

ACS PNL ACCESS PANEL

ACST ACOUSTIC

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES

ACT

ADC AUTOMATIC DOOR CLOSER

ADDL ADDITIONAL

ADDN ADDITION

ADH ADHESIVE

ADJ ADJACENT, ADJOINING, OR

ADJUSTABLE

ADMIN ADMINISTRATION

ADB AUTOMATIC DOOR BOTTOM

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGA AMERICAN GAS ASSOCIATION

AGC ASSOCIATED GENERAL

CONTRACTORS

AGGR AGGREGATE

AHJ AUTHORITY HAVING

JURISDICTION

AHR ANCHOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF

ARCHITECTS

AISC AMERICAN INSTITUTE OF STEEL

CONSTRUCTION

ALT ALTERNATE

ALT NO ALTERNATE NUMBER

ALUM ALUMINUM

AMP AMPERE

AMT AMOUNT

ANOD ANODIZED

ANSI AMERICAN NATIONAL

STANDARDS INSTITUTE

ANT ANTENNA

APA AMERICAN PLYWOOD

ASSOCIATION

APPD APPROVED

APPROX APPROXIMATE

APT APARTMENT

AR AS REQUIRED

ARCH ARCHITECT

ASB ASBESTOS

ASI ARCHITECT'S SUPPLEMENTAL

INSTRUCTION

ASKLR AUTOMATIC SPRINKLER

ASPH ASPHALT

ASSN ASSOCIATION

ASTM AMERICAN SOCIETY FOR TESTING

AND MATERIALS

ATCH ATTACHMENT

ATM AUTOMATIC TELLER MACHINE

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AVE AVENUE

AVG AVERAGE

AW ACID WASTE

AWI ARCHITECTURAL WOODWORKING

INSTITUTE

AWPA AMERICAN WOOD PRESERVERS'

ASSOCIATION

AWS AMERICAN WELDING SOCIETY

AWT ACOUSTICAL WALL TREATMENT

B LABEL CLASS B DOOR

B PL BASE PLATE

BALC BALCONY

BAT BATTEN

BB BULLETIN BOARD

BD BOARD

BD FT BOARD FEET (FOOT)

BEV BEVEL

BHMA BUILDER'S HARDWARE

MANUFACTURER'S ASSOCIATION

BI FLD DR BIFOLDING DOORS

BITUM BITUMINOUS

BKG BACKING

BLD BUILD

BLDG BUILDING

BLKT BLANKET

BLVD BOULEVARD

BM BEAM OR BENCHMARK

BOT BOTTOM

BR BEDROOM

BRCG BRACING

BRDG BRIDGING

BRDG JST BRIDGING JOIST

BRG BEARING

BRG PL BEARING PLATE

BRKT BRACKET

BRZ BRONZE

BSMT BASEMENT

BTWN BETWEEN

BU BUSHEL

BUR BUILT-UP ROOFING

ARCHITECTURAL ABBREVIATIONS

C CELSIUS CHANNEL

C CHANNEL CELSIUS

C CONC CAST CONCRETE

C LABEL CLASS C DOOR

C TO C CENTER TO CENTER

CAB CABINET

CAC CEILING ATTENUATION CLASS

CB CATCH BASIN OR CORNER BEAD

CBB CEMENTITIOUS (BACKER) BOARD

CC CUBIC CENTIMETER

CCTV CLOSED CIRCUIT TELEVISION

CCW COUNTERCLOCKWISE

CD CONSTRUCTION DOCUMENTS OR

CONTRACT DOCUMENTS

CEM CEMENT

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR

FURNISHED/CONTRACTOR

INSTALLED

CF/OI CONTRACTOR

FURNISHED/OWNER INSTALLED

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CENTER OF GRAVITY OR CORNER

GUARD

CGSFU CERAMIC GLAZED STRUCTURAL

FACING UNITS

CH BD CHALKBOARD

CHEM CHEMICAL

CHFR CHAMFER

CHK CHECK

CI CAST IRON

CIP CAST-IN-PLACE

CIR CIRCLE

CIRC CIRCULAR

CJ CONSTRUCTION JOINT OR

CONTROL JOINT

CL CENTER LINE

CLDG CLADDING

CLG CEILING

CLG HT CEILING HEIGHT

CLR CLEAR

cm² SQUARE CENTIMETER cm³ CUBIC CENTIMETER

CM CONSTRUCTION MANAGEMENT

CMU CONCRETE MASONRY UNIT

CNR CORNER

CNTR COUNTER

CO CARBON MONOXIDE,

CERTIFICATE OF OCCUPANCY,

CLEANOUT, OR COMPANY

CO2 CARBON DIOXIDE

COL COLUMN

COM COMMON

COMB COMBINATION, COMBINED

COMM COMMUNICATION

COMP COMPONENT

CONC CONCRETE

CONC FLR CONCRETE FLOOR

COND CONDENSER OR CONDITION

CONF CONFERENCE

CONN CONNECT

CONSTR CONSTRUCTION

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CORR CORRIDOR

CPM CRITICAL PATH METHOD

CPRS COMPRESSIBLE

CPT CARPET

CRS COLD ROLLED STEEL

CRSI CONCRETE REINFORCING STEEL

INSTITUTE

CSB CONCRETE SPLASH BLOCK

CSG CASING

CSI CONSTRUCTION SPECIFICATIONS

INSTITUTE

CSK COUNTER SUNK

CSMT CASEMENT

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTG COATING

CTR CENTER CONTOUR

CTRL CONTROL

CTV CABLE TELEVISION

CU COPPER C

CU FT CUBIC FEET

CU IN CUBIC INCH

CU YD CUBIC YARD

CURT CURTAIN

CYL CYLINDER

CYL L CYLINDER LOCK

D DEPTH OR PENNY (NAIL)

D LABEL CLASS D DOOR

DAT DATUM

DB DECIBEL

DBL DOUBLE

DBL GLZ DOUBLE GLAZE

DC DIRECT CURRENT

DEG DEGREE

DEL DELETE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL DIAGRAM

DIAG DIAGRAM DIAGONAL

DIFF DIFFERENCE OR DIFFUSER

DIM DIMENSION

DIR DIRECTION

DISP DISPENSER

DIST DISTANCE

DIV DIVIDE OR DIVISION

DL DEAD LOAD

DOC DOCUMENT

DOUG FIR DOUGLAS FIR

DOZ DOZEN

DR DOOR, DRAIN, DRESSING

ROOM, OR DRIVE

DR CL DOOR CLOSER

DR FR DOOR FRAME

DR OPNG DOOR OPENING

DS DOWNSPOUT

DSGN DESIGN

DW DISHWASHER

DWG DRAWING

DWTR DUMBWAITER

E EAST

E LABEL CLASS E DOOR

EA EACH

EFF EFFICIENCY

EFS EXTERIOR FINISH SYSTEM

EIFS EXTERIOR INSULATION AND

FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELAST ELASTOMERIC

ELEC ELECTRIC

ELEC DR OP ELECTRIC DOOR OPENER

ELEV ELEVATOR

EMER EMERGENCY

EMER SHR EMERGENCY SHOWER

ENCL ENCLOSURE

ENGR ENGINEER

ENVIR ENVIRONMENT

EPA ENVIRONMENTAL PROTECTION

AGENCY

EPDM ETHYLENE PROPYLENE DIENE

MOMOMER

EPO EMERGENCY POWER OFF

EPS EXPANDED POLYSTYRENE

BOARD (INSULATION)

EQ EQUAL

EQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EQUIV EQUIVALENT

ERD EXISTING ROOF DRAIN

ESC ESCAPE OR ESCUTCHEON

ESCAL ESCALATOR

ESMT EASEMENT

ESP ESPECIALLY

EST ESTIMATE

ETC AND SO FORTH OR ET CETERA

EW EACH WAY

EWC ELECTRIC WATER COOLER

EWS EYE WASH STATION

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION OR EXPOSED

EXP BT EXPANSION BOLT

EXST GR EXISTING GRADE

EXT EXTERIOR, EXTERNAL, OR

EXTINGUISHER

EXT GR EXTERIOR GRADE

F FAHRENHEIT OR FEMALE

FA FIRE ALARM

FAB FABRIC

FAC FACTOR

FACIL FACILITY

FAS FASCIA

FAS BD FASCIA BOARD

FCO FLOOR CLEANOUT

FCTY FACTORY

FD FLOOR DRAIN

FDC FIRE DEPARTMENT

CONNECTION

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF&E FURNITURE, FIXTURE, AND

EQUIPMENT

FH FLAT HEAD OR FLAT HEAD

SCREWS

FHC FIRE HOSE CABINET

FHMS FLAT HEAD MACHINE SCREW

FHP FULL HEIGHT PARTITION

FHWS FLAT HEAD WOOD SCREW

FIG FIGURE

FIL FILLET

FIN FINISH

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIN WD FINISH WOOD

FIXT FIXTURE

FL FLOORLINE

FLASH FLASHING

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLR FLOOR

FLR FIN FLOOR FINISH

FLR SK FLOOR SINK

FLUOR FLUORESCENT

FLUOR FIX FLUORESCENT FIXTURE

FM FACTORY MUTUAL

FM-G FACTORY MUTUAL GLOBAL

FO FINISHED OPENING

FOC FACE OF CONCRETE OR FACE

OF CURB

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF SLAB OR FACE OF STUD

FOUNT FOUNTAIN

FOW FACE OF WALL

FP FIRE PROTECTION OR FIREPROOF

FPM FEET PER MINUTE

FPS FEET PER SECOND

FR FIRE RATING, FIRE RESISTANT,

OR FRAME

FR SNK FLUSHING RIM SINK

FREQ FREQUENCY

FRMG FRAMING

FRP FIBER REINFORCED POLYESTER

OR

FIBERGLASS REINFORCED

PLASTIC

FRZ FREEZER

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET OR FOOT

FTG FOOTING

FURG FURRING

FURN FURNISH OR FURNITURE

FUT FUTURE

FWC FABRIC WALLCOVERING

GA GAGE OR GYPSUM ASSOCIATION

GAL GALLON

GALV GALVANIC OR GALVANIZED

GALV STL GALVANIZED STEEL

GB GRAB BAR

GC GENERAL CONTRACTOR

GD GUARD

GDR GUARD RAIL

GEN GENERAL OR GENERATOR

GFRC GLASS-FIBER-REINFORCED

CONCRETE

GFRG GLASS-FIBER-REINFORCED

GYPSUM

GFRP GLASS-FIBER-REINFORCED

PLASTIC

GI GALVANIZED IRON

GL GLASS

GL BLK GLASS BLOCK

GLU LAM GLUED LAMINATED WOOD

GR FL GROUND FLOOR

GRAN GRANITE

GRTG GRATING

GSB GYPSUM SHEATHING BOARD

GSM GALVANIZED SHEET METAL

GSU GLAZED STRUCTURAL UNIT

GT GROUT

GUAR GUARANTEE

GUT GUTTER

GYP GYPSUM

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H HIGH

H PLAM HIGH PRESSURE PLASTIC

LAMINATE

HAZ MAT HAZARDOUS MATERIALS

HB HOSE BIB

HC HOLLOW CORE

HCWD HOLLOW CORE WOOD DOOR

HDBD HARDBOARD

HDNR HARDENER

HDO HIGH DENSITY OVERLAY

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE

AIR (FILTER)

HEX HEXAGON

HF HIGH FREQUENCY

HGR HANGER

HM HECTOMETER

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMDF HOLLOW METAL DOOR AND

FRAME

HMF HOLLOW METAL FRAME

HNDRL HANDRAIL

HO HOLD OPEN

HORIZ HORIZONTAL

HOSP HOSPITAL

HP HIGH PRESSURE OR

HORSEPOWER

HQ HEADQUARTERS

HS HEAT-STRENGTHENED (GLASS)

OR HIGH STRENGTH

HSE HOUSE

HSKPG HOUSEKEEPING

HST HOIST

HT HEIGHT

HVAC HEATING, VENTILATING, AND AIR

CONDITIONING

HVY HEAVY

HW HOT WATER

HYD HYDRANT

HYDR HYDRAULIC

I INTERSTATE (HIGHWAY) OR

MOMENT OF INERTIA

IAQ INDOOR AIR QUALITY

IBC INTERNATIONAL BUILDING CODE

ID IDENTIFICATION, INSIDE

DIAMETER, OR INTERIOR DESIGN

ID NO IDENTIFICATION NUMBER

ILLUM ILLUMINATION

INCL INCLUDED

IND INDEPENDENT OR INDUSTRIAL

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INTERCOM INTERCOMMUNICATION

INTL INTERNATIONAL

IRMA INVERTED ROOF MEMBRAME

ASSEMBLY

IWH INSTANTANEOUS WATER

HEATER

JAN JANITOR

J-BOX JUNCTION BOX

KD KILN DRIED OR KNOCKED

DOWN

KIT KITCHEN

KO KNOCKOUT

KPL KICKPLATE

L ANGLE

LAB LABORATORY

LAD LADDER

LAM LAMINATE

LAM GL LAMINATED GLASS

LAU LAUNDRY

LAV LAVATORY

LBR LUMBER

LBS POUND

LD BRG LOAD-BEARING

LDR LEADER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LH LEFT HAND

LHR LEFT HAND REVERSE

LHR LEFT HAND REVERSE LATENT

HEAT RATION

LIB LIBRARY

LIN LINEAR

LINO LINOLEUM

LIQ LIQUID

LKR LOCKER

LKR RM LOCKER ROOM

LKWASH LOCKERWASHER

LL LEAD LINED

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LMST LIMESTONE

LNDSCP LANDSCAPE

LR LIVING ROOM

LRG LARGE

LRV LOUVERED ROOF VENT

LS LUMP SUM

LT LIGHT

LT GA LIGHT GAGE

LT WT LIGHTWEIGHT

LTG LIGHTING

LTNG LIGHTNING

LVD LOUVERED

LVR LOUVER

LWC LIGHTWEIGHT CONCRETE

LWIC LIGHTWEIGHT INSULATION

CONCRETE

LYR LAYER

MACH MACHINE

MACH RM MACHINE ROOM

MAINT MAINTENANCE

MAN MANUAL

MATL MATERIAL

MATV MASTER ANTENNA TELEVISION

SYSTEM

MAX MAXIMUM

MB MACHINE BOLT

MCB METAL CORNER BEAD

MD DECK

ME MECHANICAL ENGINEER

MEAS MEASURE

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MED MEDICAL MEDIUM

MED MEDIUM MEDICAL

MEK METHYL ETHYL KETONE

MEL MELAMINE

MEMB MEMBRANE

MEMO MEMORANDUM

MEZZ MEZZANINE

MF MILL FINISH

MFD MANUFACTURED

MFG MANUFACTURING

MFR MANUFACTURER

MFR REC MANUFACTURER'S

RECOMMENDATION

MGT MANAGEMENT

MH MANHOLE

MIC MICROPHONE

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM MINUTE

MIN MINUTE MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MIT MITER

MKR MARKER

ML METAL LATH

MLDG MOLDING (MOULDING)

MLWK MILLWORK

mm MILLIMETER

MO MASONRY OPENING OR MOTOR

OPERATED

MOD MODEL, MODIFY OR MODULE

MOD BIT MODIFIED BITUMEN

MON MONITOR

MOPR MOP RACK

MR MOISTURE RESISTANT

MS MACHINE SCREW OR MOP SINK

MTD MOUNTED

MTG MOUNTING

MTL METAL

MULL MULLION

MW MICROWAVE

MWP MEMBRANE WATERPROOFING

N NORTH

NA NOT APPLICABLE

NAAMM NATIONAL ASSOCIATION OF

ARCHITECTURAL METAL

MANUFACTURERS

NAT NATURAL

NATL NATIONAL

NC NOISE CRITERIA

NCOMBL NONCOMBUSTIBLE

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NEUT NEUTRAL

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NR NOISE REDUCTION

NRC NOISE REDCTION COEFFICIENT

NRCA NATIONAL ROOFING

CONTRACTORS ASSOCIATION

NRP NONREMOVABLE

NS NARROW STILE

NUM NUMERAL

O/O OUT TO OUT

O OXYGEN

OA OUTSIDE AIR OR OVERALL

OC ON CENTER

OCC OCCUPY

OCT OCTAGON

OD OUTSIDE DIAMETER OUTSIDE

DIMENSION

OD OUTSIDE DIMENSION OUTSIDE

DIAMETER

OF/CI OWNER

FURNISHED/CONTRACTOR

INSTALLED

OFD OVERFLOW DRAIN

OFF OFFICE

OF/OI OWNER FURNISHED/OWNER

INSTALLED

OH OVERHANG

OH DR OVERHEAD (COILING) DOOR

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

OPT OPTIONAL

OR OPERATING ROOM OR OUTSIDE

RADIUS

ORD ORDNANCE OR OVERFLOW ROOF

DRAIN

ORG ORGANIC

ORIG ORIGINAL

ORN ORNAMENTAL

OSHA OCCUPATIONAL SAFETY AND

HEALTH ADMINISTRATION

OUT OUTLET

OZ OUNCE

PAR PARALLEL OR PARAPET

PARA PARAGRAPH

PART PARTIAL

PAT PATTERN

PB PUSH BUTTON

PBD PARTICLE BOARD

PC PIECE, POLYCARBONATE OR

PORTLAND CEMENT

PCA PORTLAND CEMENT

ASSOCIATION

PCC PRECAST CONCRETE

PCCP CONCRETE PAVEMENT

PCD PAPER CUP DISPENSER

PCF POUNDS PER CUBIC FOOT

PCP PORTLAND CEMENT PLASTER

PED PEDESTAL

PEN PENETRATE

PEND PENDANT

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PGBD PEGBOARD

PHAR PHARMACY

PHOTO PHOTOGRAPH

PHS PHILLIPS HEAD SCREW

PKG PACKAGE

PL PROPERTY LINE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER OR PLASTIC

PLBG PLUMBING

PLYWD PLYWOOD

PMTL PAINTED METAL

PNEU PNEUMATIC

PNL PANEL

PO POST OFFICE PURCHASE ORDER

PO PURCHASE ORDER POST OFFICE

POLY POLYETHYLENE (PLASTIC)

PR PAIR

PRCST PRECAST

PREFAB PREFABRICATE

PREFIN PREFINISH

PRELIM PRELIMINARY

PREP PREPARATION

PRESS PRESSURE

PREV PREVIOUS

PRKG PARKING

PRMLD PREMOLDED

PROJ PROJECT

PROP PROPERTY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT, PNEUMATIC TUBE, OR

PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTN PARTITION

PVC POLYVINYL CHLORIDE (PLASTIC)

PVG PAVING

PWR POWER

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QRY QUARRY

QT QUARRY TILE

QTB QUARRY TILE BASE

QTF QUARRY TILE FLOOR

QTR QUARTER

QTY QUANTITY

QUAD QUADRANT

QUAL QUALITY

R RADIUS OR RISER

RA RETURN AIR

RAD RADIATOR

RB RESILIENT BASE OR RUBBER

BASE

RB HK ROBE HOOK

RBM REINFORCED BRICK MASONRY

RBR RUBBER

RC REMOTE CONTROL

RCP REFLECTED CEILING PLAN

RCVR RECEIVER

RD ROAD OR ROOF DRAIN

REC RECESSED

RECD RECEIVED

RECPT RECEPTACLE

RECT RECTANGLE

REF REFERENCE OR REFRIGERATOR

REFR REFRACTORY REFRIGERATION

REFR REFRIGERATION REFRACTORY

REG REGISTER

REINF REINFORCE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

RET RETURN

REV REVISION

RF RADIO FREQUENCY

RFG ROOFING

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RHMS ROUND HEAD MACHINE SCREW

RHR RIGHT HAND REVERSE

RHWS ROUND HEAD WOOD SCREW

RL ROOF LEADER

RLG RAILING

RM ROOM

RND ROUND

RO ROUGH OPENING

ROW RIGHT OF WAY

RPM REVOLUTIONS PER MINUTE

RS ROUGH SAWN

RT RIGHT

RV ROOF VENT

RVS REVERSE

RWD REDWOOD

RWL RAIN WATER LEADER

SA SUPPLY AIR

SALV SALVAGE

SAMP SAMPLE

SAN SANITARY

SAT SUSPENDED ACOUSTICAL TILE

SATC SUSPENDED ACOUSTICAL TILE

CEILING

SB SPLASH BLOCK

SBS STYRENE BUTADIEN STYRENE

SBSTR SUBSTRATE

SC SHADING COEFFICIENT OR SOLID

CORE

SCH SCHOOL

SCHED SCHEDULE

SCHEM SCHEMATIC

SCP SCUPPER

SCRN SCREEN

SCT STRUCTURAL CLAY TILE

SCWD SOLID CORE WOOD DOOR

SD SHOP DRAWINGS, SMOKE

DETECTOR, OR SOAP DISPENSER

SDG SIDING

SECT SECTION

SEG SEGMENT

SEL SELECT

SEP SEPARATE

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SGD SLIDING GLASS DOOR

SGL SINGLE

SHR SHOWER

SHR HD SHOWER HEAD

SHRD SHOWER DRAIN

SHT SHEET

SHT MTL FLASH SHEET METAL (FLASHING)

SHTHG SHEATHING

SHV SHELVING

SIM SIMILAR

SJ SCORED JOINT

SJI STEEL JOIST INSTITUTE

SK SKETCH

SKLT SKYLIGHT

SLD WDW HORIZONTAL SLIDING

WINDOW

SLDG SLIDING

SLNT SEALANT

SM SHEET METAL

SMK SMOKE

SND SANITARY NAPKIN

DISPENSER

SND INS SOUND INSULATION

SNDU SANITARY NAPKIN

DISPOSAL UNIT

SPEC SPECIFICATION

SPKLR SPRINKLER

SPKR SPEAKER

SPLY SUPPY

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SS SANITARY SEWER OR

SERVICE SINK

SST STAINLESS STEEL

ST STAIRS OR STREET

STC SOUND TRANSMISSION

CLASS

STD STANDARD

STIF STIFFENER

STL JST STEEL JOIST

STL LNTL STEEL LINTEL

STL PL STEEL PLATE

STL RF DK STEEL ROOF DECK

STL TB STEEL TUBE

STL TR STEEL TRUSS

STNLS STAINLESS

STOR STORAGE

STR STRINGERS

STRUCT STRUCTURAL

STRUCT STL STRUCTURAL STEEL

SUB SUBSTITUTE

SURF SURFACE

SUSP SUSPEND

SUSP CLG SUSPENDED CEILING

SV SHEET VINYL

SW SWITCH

SWDR SWING DOOR

SYM SYMBOL

SYNTH SYNTHETIC

SYS SYSTEM

T TREAD

T&G TONGUE AND GROOVE

T&M TIME AND MATERIALS

TB THROUGH BOLT OR TOWEL

BAR

TCA TILE COUNCIL OF AMERICA

TCP TELEPHONE CONTROL

PANEL TEMPERATURE OR

TRAFFIC CONTROL PLAN

TD TOWEL DISPENSOR

TECH TECHNICAL

TEL TELEPHONE

TEMP TEMPERATURE OR

TEMPORARY

TER TERRAZZO

THD THREAD

THERM THERMAL

THK THICKNESS

THRES THRESHOLD

THRU THROUGH

THRUOUT THROUGHOUT

TK BD TACKBOARD

TMPD TEMPERED

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TO TOP OF ___

TO FDN TOP OF FOUNDATION

TOB TOP OF BEAM

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOS TOP OF STEEL

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TPH TOILET PAPER HOLDER

TR TOWEL RACK

TRANS TRANSOM

TRANS WD FIN TRANSPARENT WOOD

FINISH

TRTD TREATED

TS TENSILE STRENGTH OR

TUBE STEEL

TSTAT THERMOSTAT

TV TELEVISION

TYP TYPICAL

U HEAT TRANSFER

COEFFICIENT

UC UNDERCUT

UCD UNDERCUT DOOR

UGND UNDERGROUND

UL UNDERWRITERS

LABORATORIES

ULT ULTIMATE

UNFIN UNFINISH

UNO UNLESS NOTED OTHERWISE

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER

SUPPLY

UR URINAL

UTIL UTILITY

UV ULTRAVIOLET

V VOLT

VAC VACUUM

VAR VARIES

VCT VINYL COMPOSITION TILE

VITRIFIED CLAY TILE

VEH VEHICLE

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

VFAT VINYL FACED ACOUSTICAL

TILE

VIC VICINTY

VID VIDEO

VIF VERIFY IN FIELD

VNR VENEER

VOC VOLATILE ORGANIC

COMPOUND

VOL VOLUME

VOLT VOLTAGE

VP VENEER PLASTER

VR VAPOR RETARDER

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

VWF VINYL WALL FABRIC

W WIDE OR WEST

W/ WITH

W/O WITHOUT

WARR WARRANTY

WBL WOOD BLOCKING

WC WALL COVERING OR WATER

CLOSET

WC WL HNG WATER CLOSET, WALL HUNG

WCHR WATER CHILLER

WCL WL MTD WATER COOLER, WALL HUNG

WD WOOD

WDW WINDOW

WF WIDE FLANGE

WFAB WALL FABRIC

WFR WOOD FRAME

WFS WOOD FURRING STRIPS

WH WATER HEATER

WHSE WAREHOUSE

WLD WELDED

WM WIRE MESH

WP WATERPROOFING

WPD WATER PRESSURE DROP

WPM WATERPROOF MEMBRANE

WPR WALL PROTECTION/RAILING

WR WEATHER RESISTANT

WS WEATHERSTRIP

WSCT WAINSCOT

WT WEIGHT

WWF WELDED WIRE FABRIC

X BRACE CROSS BRACE

XPS EXTRUDED POLYSTYRENE

BOARD (INSULATION)

YD YARD

YR YEAR

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

ARCHITECT OF RECORDCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

569A4-22-700

5/16/23

100% CONSTRUCTION

DOCUMENTS

LEXINGTON-COOPER EHRM

INFRASTRUCTURE DESIGN

1101 VETERANS DRIVE

LEXINGTON, KY 40502

5/16/23 JY

GI-030

ARCHITECTURAL

ABBREVIATIONS

60" MINIMUM 60" MINIMUM

A. MINIMUM CLEAR WIDTH

FOR TWO WHEELCHAIRS

B. MINIMUM CLEAR WIDTH FOR

SINGLE WHEELCHAIR

1 MINIMUM CORRIDOR WIDTH

48" MINIMUM DOOR WIDTH

2 TWO HINGED DOORS IN A SERIES

A

DOOR WIDTH DOOR WIDTH48" MINIMUM

B C

60" MINIMUM

60" MINIMUM 60" MINIMUM

A. MINIMUM TURNING SPACE B. MINIMUM CLEAR WIDTH

3 MINIMUM TURNING SPACE/CLEAR WIDTH

" M

IN

IM

U M

" M

AX

IM

U M

36" MINIMUM

A. FORWARD APPROACH B. PARALLEL APPROACH

4 MANEUVERING CLEARANCE IN AN ALCOVE

X>

X>15"

" M

IN

IM

U M

" M

IN

IM

U M

A. FRONT APPROACH

" M

IN

IM

U M

B. POCKET OR HINGE APPROACH

22"

MINIMUM

C. STOP OR LATCH APPROACH

" M

IN

IM

U M

24"

MINIMUM

5 SLIDING DOOR APPROACH

6 WHEELCHAIR TURNING RADIUS

60" MINIMUM

" M

IN

IM

U M

7 CLEAR FLOOR GROUND SPACE

30" MINIMUM

" M

IN

IM

U M

SPACE NEEDED TO

TURN A WHEELCHAIR

8 T-SHAPED TURNING SPACE

60" MINIMUM

" M

IN

IM

U M

M

IN

IM

U

M 60 " M

IN

IM

U M

60" MINIMUM12"

MIN.

12"

MIN.

BASE

AR

M

AR

M

48" MINIMUM 36" MINIMUM

" M

IN

IM

U M

ACCESSIBLE PATH OF TRAVEL

A. CLEARANCES FOR SEATING

9 MINIMUM CLEARANCES FOR SEATING & TABLES

60" MINIMUM 19"

MINIMUM

B. CLEARANCES FOR TABLES

ACCESSIBLE PATH OF TRAVEL

" M

IN

IM

U M

30" MINIMUM

" M

IN

IM

U M

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

ARCHITECT OF RECORDCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

569A4-22-700

5/16/23

100% CONSTRUCTION

DOCUMENTS

LEXINGTON-COOPER EHRM

INFRASTRUCTURE DESIGN

1101 VETERANS DRIVE

LEXINGTON, KY 40502

5/16/23 JY

GI-040

ACCESSIBILITY STANDARDS

11" MINIMUM

" M

IN

IM

U M

8" MINIMUM

25" MAXIMUM

9" M

IN

IM

U M

" M

IN

IM

U M

1 KNEE CLEARANCE

A. ELEVATION B. PLAN

2 TOE CLEARANCE

6"

MINIMUM

17"-25"

9"

" M

IN

IM

U M

A. ELEVATION B. PLAN

" M

AX

IM

U M

10"

MAXIMUM

" M

AX

IM

U M

3 OBSTRUCTED HIGH SIDE REACH

A

" M

AX

IM

U M

X>10"-24" MAXIMUM

" M

AX

IM

U M

B

4 UNOBSTRUCTED SIDE REACH

10"

MAXIMUM

" M

AX

IM

U M

" M

IN

IM

U M

" M

IN

IM

U M

M

IN

IM

U

M

" M

IN

IM

U M

M

IN

IM

U

M

48" MINIMUM 24" MAXIMUM24" MAXIMUM

5 CLEAR WIDTH OF AN ACCESSIBLE ROUTE

6 OBSTRUCTED HIGH FORWARD REACH

" M

AX

IM

U M

20" MAXIMUM

A

" M

AX

IM

U M

20"-25" MAXIMUM

7 UNOBSTRUCTED FORWARD REACH

" M

AX

IM

U M

" M

IN

IM

U M

A. PULL SIDE C. PUSH SIDE, DOOR PROVIDED

WITH BOTH CLOSER AND LATCHB. PUSH SIDE

8 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES

" M

IN

IM

U M

X> 8"

" M

IN

IM

U M

X> 8"

12" MINIMUM

" M

IN

IM

U M

X> 8"

18" MINIMUM

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

ARCHITECT OF RECORDCONSULTANTRevisions: Date:

This is the start of the file's text. The full file is on GovTribe.