589A4-20-155-Final Drawings 072121 VOL 1 - 47 pages.pdf

PDF 14 MB Posted

Attached to
Z2DA--Complete Unfinished Specialty Clinic P/N: 589A4-20-155
Solicitation number
36C25521R0106
Issued by

About this file

This document provides details for a federal construction solicitation for a complete unfinished specialty clinic project. The solicitation seeks to renovate approximately 6,490 square feet for an outpatient hematology/oncology clinic and 6,290 square feet for the main inpatient pharmacy at the Harry S. Truman Memorial VA Hospital in Columbia, Missouri. Renovations include new exam rooms, infusion bays, waiting areas, nurse stations, clean and soiled rooms, and office spaces for the clinic, as well as remodeling pharmacy compounding areas to comply with USP standards. The estimated price range for the project is $2,000,000 to $5,000,000. The solicitation will be set aside for Service-Disabled Veteran-Owned Small Businesses and issued on July 16, 2021, with proposals due on August 18, 2021. The contract will be awarded using the Best Value Lowest Price Technical Acceptable source selection process. The duration of the project is up to 300 calendar days from notice to proceed. The Department of Veterans Affairs Veterans Health Administration VISN 15 is the contracting agency.

View the file

Other files

File Type Posted
36C25521R0106 0003 Amendment 3.pdf PDF
QH101 - BASEMENT EQUIPMENT PLAN.pdf PDF
Amendment 3 Narrative.docx DOCX document
QH102 - THIRD FLOOR EQUIPMENT PLAN.pdf PDF
36C25521R0106 0002 Amendment 2.pdf PDF
Amendment 2-ATTENDANCE ROSTER- Complete Unfinished Specialty Clinic_08032021.xlsx XLSX spreadsheet
090600 Schedule for Finishes_amendment 1.pdf PDF
066060 Plastic Fabrications amendment 1.pdf PDF
077100 Roof Specialties_amendment 1.pdf PDF
072200 Roof and Deck Insulation amendment 1.pdf PDF
077200 Roof Accessories_amendment 1.pdf PDF
083459 Vaults and Day Gates_amendment 1.pdf PDF
111736 Package Transfer Units_amendment 1.pdf PDF
076000 Flashing and Sheet Metal_amendment 1.pdf PDF
Revised Columbia USC Amendment 1 - Combined Drawings.pdf PDF
075423 Thermoplastic Polyolefin -TPO- Roofing_amendment 1.pdf PDF
36C25521R0106 0001- Amendment 1.pdf PDF
072727 Fluid-Applied Membrane Air Barrier- Vapor amendment 1.pdf PDF
224000 Plumbing Fixtures amendment 1.pdf PDF
096723_20 Resinous with Vinyl Chip Broadcast_amendment 1.pdf PDF
149200 Pneumatic Tube System amendment 1.pdf PDF
Complete Unfinished Specialty Clinics Specifications VOL 1- 486 pages.pdf PDF
Complete Unfinished Specialty Clinics-589A4-20-155 Specifications VOL 2-742 pages.pdf PDF
36C25521R0106.docx DOCX document
589A4-20-155-Final Drawings 072121 VOL 2 - 60 Pages.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWING LIST

PROJECT INFORMATION

THIS PROJECT WILL CONSTRUCT APPROXIMATELY 6,490 SQUARE FEET OF SPACE ON THE 3RD FLOOR AND APPROXIMATELY 6,290 SQUARE FEET ON THE BASEMENT FLOOR. THE 3RD FLOOR SPACE WILL CONTAIN A HEMATOLOGY / ONCOLOGY CLINIC AND ALL ASSOCIATED SUPPORT AREAS. THE BASEMENT FLOOR SPACE WILL CONTAIN PHARMACY OFFICES AND COMPOUNDING ROOMS

AND INCLUDE ALL ASSOCIATED SUPPORT AREAS.

VICINITY MAPBUILDING SUMMARY

PROJECT NAME: COMPLETE UNFINISHED SPECIALTY CLINIC

PROJECT NUMBER: 589A4-20-155

PROJECT LOCATION: HARRY S. TRUMAN MEMORIAL HOSPITAL

BUILDING AREA:

BASEMENT FLOOR 6,290 GSF

3RD FLOOR 6,490 GSF

1. THESE DRAWINGS SHALL BE USED ONLY FOR THIS SPECIFIC PROJECT/SITE LOCATION. THESE DRAWINGS ARE A COMPOSITE SET OF CONTRACT DOCUMENTS AND SHALL NOT BE SEPARATED FOR DISTRIBUTION. THE GC SHALL REVIEW ALL DRAWINGS

AND PROVIDE/DISTRIBUTE THE ENTIRE SET TO EACH SUBCONTRACTOR.

2. THE GC SHALL VISIT THE SITE TO INSPECT EXISTING CONDITIONS AND VERIFY WORK BEING PERFORMED BEFORE SUBMITTING

COST QUOTATIONS FOR WORK.

3. NOTIFY THE C.O.R. PROMPTLY OF ANY ERRORS, OMISSIONS, INCONSISTENCIES, DISCREPANCIES AND CONFLICTS WITHIN THE CONTRACT DOCUMENTS AND ITS ASSOCIATED FIELD/PROJECT CONDITIONS SO THAT A RESOLUTION CAN BE PROVIDED PRIOR

TO CONTINUING WITH WORK.

4. DO NOT SCALE THE DRAWINGS. REQUEST ANY MISSING DIMENSIONS FROM THE ARCHITECT.

5. ALL WORK PERFORMED SHALL BE IN STRICT COMPLIANCE WITH GOVERNING FEDERAL, STATE AND LOCAL BUILDING CODE REQUIREMENTS, SHALL BE EXECUTED IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARDS, AND SHALL CONFORM TO SPECIFIC REGULATIONS AS MANDATED BY THE OWNER, THE ARCHITECT, AND THE AUTHORITIES HAVING JURISDICTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY FEES ASSOCIATED WITH PROCURING SUCH PERMITS AND CERTIFICATES

AND SHALL FURNISH COPIES OF PERMITS, INSPECTIONS, AND CERTIFICATES TO THE OWNER.

6. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK TO MINIMIZE DISRUPTION OF ANY EXISTING TENANTS OR BUILDING OPERATIONS. THE GENERAL CONTRACTOR SHALL TAKE ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS, AND EXISTING CONSTRUCTION THROUGHOUT ALL PHASES OF CONSTRUCTION. DAMAGE TO EXISTING-TO-REMAIN CONSTRUCTION OR EQUIPMENT SHALL BE RESTORED TO ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE.

7. THE GENERAL CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE ON A DAILY BASIS.

8. ANY REQUESTS FOR SUBSTITUTIONS OF ANY SPECIFIED ITEM ARE TO BE SUBMITTED TO THE C.O.R. IN WRITING AND WILL BE CONSIDERED ONLY IF THE ALTERNATE PROPOSED IS PROVEN TO BE ADVANTAGEOUS TO THE OWNER WITH RESPECT TO

DELIVERY DATE, QUALITY, OR COST.

9. THE MEANS AND METHODS OF CONSTRUCTION, AND TEMPORARY STRUCTURES AND FACILITIES, ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE ARCHITECT DOES NOT ASSUME ANY RESPONSIBILITY FOR THE CONTRACTOR'S MEANS AND

METHODS OR FOR TEMPORARY STRUCTURES.

10. DEMOLITION OF EXISTING STRUCTURES IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE CONTRACTOR SHALL

EMPLOY ENGINEERING EXPERTISE AS NEEDED TO ASSIST IN DEMOLITION.

11. JOB SITE SAFETY AND SECURITY ARE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL CONSULT WITH LOCAL FIRE AUTHORITIES TO ASCERTAIN REQUIREMENTS FOR FIRE SUPPRESSION AND SAFETY DURING CONSTRUCTION. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR MEETING OSHA REGULATIONS DURING

CONSTRUCTION.

12. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR STORAGE AND PROTECTION OF BUILDING MATERIALS, AND INSTALLED CONSTRUCTION, FROM INCLEMENT WEATHER, THEFT, AND OTHER HAZARDS. THE GC SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS FOR STORAGE OF MATERIALS. PARTIALLY COMPLETED WALLS SHALL BE COVERED TO PROTECT FROM WATER INTRUSION. DAMAGE, INCLUDING BUT NOT LIMITED TO MOLD, RESULTING FROM WATER INTRUSION

DURING CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE.

SCOPE OF WORK SUMMARY:

GENERAL NOTES

PROJECT TEAM

AREA OF WORK

VA LEADERSHIP SIGNATURES

MEDICAL CENTER DIRECTOR

ASSOCIATE DIRECTOR

ASSISTANT DIRECTOR

SPECIALTY CARE CHIEF

ASSOCIATE DIRECTOR FOR PATIENT SERVICES

EXECUTIVE OF HIGH RELIABILITY

PHARMACY CHIEF

CHIEF ENGINEER

INFECTION CONTROL PRACTITIONER

SAFETY OFFICER

Romanyk Consulting Focusing on what matters

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

VA FORM 08 - 6231

F

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

8910 7 6 5 4 3 2 1

U.S. Department of Veterans Affairs

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

IM

/V

IS

N

C o lu m b ia C o m p le te U n fi n is h e d S p e c ia lt y C lin ic

/C o lu m b ia U n fi n is h e d S p e c C lin ic

V

.r v t

/2

/2

:2

:1

A

M

VA PROJECT NUMBER - 589A4-20-155

COMPLETE UNFINISHED SPECIALTY CLINIC

100% FINAL CONSTRUCTION DOCUMENTS

JUNE 25, 2021

MK LJ

589A4-20-155

GI100

589A4 - COLUMBIA, MO

JUNE 25, 2021

01-

SHEET INDEX & GENERAL INFORMATION 100% FINAL CONSTRUCTION

DOCUMENTS

COMPLETE UNFINISHED SPECIALTY

CLINIC

SHEET # SHEET TITLE

MH111 LEVEL 01 PLAN - HVAC

MH121 LEVEL 02 PLAN - HVAC

MH125 INTERSTITIAL PLAN - HVAC

MH131 LEVEL 03 PLAN - HVAC

MH141 ROOF PLAN - HVAC

MH300 HVAC DETAILS

MH301 HVAC DETAILS

MH400 HVAC SCHEDULES

MH401 HVAC SCHEDULES

MI101 BASEMENT PLAN - MECHANICAL INSTRUMENTATION

MI131 LEVEL 03 PLAN - MECHANICAL INSTRUMENTATION

MP101 BASEMENT PLAN - PIPING

MP131 LEVEL 03 PLAN - PIPING

MP300 PIPING DETAILS

MP400 PIPING SCHEDULES

PLUMBING

PD001 UNDER FLOOR PLAN - PLUMBING DWV DEMOLITION

PP001 UNDER FLOOR PLAN - PLUMBING DWV

P-001 PLUMBING LEGEND, SCHEDULES AND ABBREVIATIONS

PD101 BASEMENT PLAN - PLUMBING DWV DEMOLITION

PD125 INTERSTITIAL PLAN - PLUMBING DWV DEMOLITION

PD131 LEVEL 03 PLAN - PLUMBING DWV DEMOLITION

PD201 BASEMENT PLAN - PLUMBING DISTRISTIBUTION DEMOLITION

PD225 INTERSTITIAL PLAN - PLUMBING DISTRISTIBUTION DEMOLITION

PD231 LEVEL 03 PLAN - PLUMBING DISTRISTIBUTION DEMOLITION

PP101 BASEMENT PLAN - PLUMBING DWV

PP125 INTERSTITIAL PLAN - PLUMBING DWV

PP131 LEVEL 03 PLAN - PLUMBING DWV

PP201 BASEMENT PLAN - PLUMBING DISTRISTIBUTION

PP225 INTERSTITIAL PLAN - PLUMBING DISTRISTIBUTION

PP231 LEVEL 03 PLAN - PLUMBING DISTRISTIBUTION

P-300 PLUMBING RISER DIAGRAM

P-400 PLUMBING DETAILS

ELECTRICAL

EJ102 ELECTRICAL SCHEDULES

E-001 ELECTRICAL LEGEND, SCHEDULES AND ABBREVIATIONS

ED101 BASEMENT PLAN - ELECTRICAL DEMOLITION

ED131 LEVEL 03 PLAN - ELECTRICAL DEMOLITION

EL101 BASEMENT PLAN - LIGHTING

EL131 LEVEL 03 PLAN - LIGHTING

EP101 BASEMENT PLAN - POWER

EP102 BASEMENT PLAN - MECHANICAL POWER

EP131 LEVEL 03 PLAN - POWER

EP132 LEVEL 03 PLAN - MECHANICAL POWER

EP141 ROOF PLAN - POWER

EJ101 ELECTRICAL ENLARGED PLANS

ET101 BASEMENT PLAN - SYSTEMS

ET131 LEVEL 03 PLAN - SYSTEMS

E-400 ELECTRICAL DETAILS

Grand total: 106

SHEET # SHEET TITLE

GENERAL

GI100 SHEET INDEX & GENERAL INFORMATION

GI101 ABBREVIATIONS

GI102 ADA INFORMATION

GI103 BUILDING CODE

GI104 BASEMENT LIFE SAFETY PLAN

GI105 THIRD FLOOR LIFE SAFETY PLAN

GI106 PHASING PLAN

GI107 PHASING PLAN

ARCHITECTURAL

AD101 BASEMENT DEMOLITION PLAN

AD102 THIRD FLOOR DEMOLITION PLAN

AD103 BASEMENT RCP DEMOLITION

AE101 BASEMENT OVERALL PLAN

AE102 THIRD FLOOR OVERALL PLAN

AE103 BASEMENT ENLARGED PLAN

AE104 THIRD FLOOR ENLARGED PLAN

AE105 BASEMENT DIMENSION PLAN

AE106 THIRD FLOOR DIMENSION PLAN

AE107 BASEMENT REFLECTED CEILING PLAN

AE108 THIRD FLOOR REFLECTED CEILING PLAN

AE401 ENLARGED TOILET PLAN AND ELEVATIONS

AE402 ENLARGED PLANS

AE403 ENLARGED PLANS

AE404 BASEMENT INTERIOR ELEVATIONS

AE405 THIRD FLOOR INTERIOR ELEVATIONS

AE500 PARTITION TYPES

AE501 ACCESSIBLE DETAILS

AE502 METAL STUD DETAILS

AE503 CEILING DETAILS

AE504 CEILING DETAILS

AE601 DOOR & WINDOW SCHEDULES

AE700 MILLWORK SECTIONS AND DETAILS

AE701 MILLWORK SECTIONS AND DETAILS

AF100 INTERIOR FINISH NOTES AND DETAILS

AF101 BASEMENT FINISH PLAN

AF102 THIRD FLOOR FINISH PLAN

AF103 THIRD FLOOR HEM/ONC WAITING FINISH PLAN

AW101 BASEMENT SIGNAGE PLAN

AW102 THIRD FLOOR SIGNAGE PLAN

AW103 SIGNAGE PLAN DETAILS

AW104 SIGNAGE PLAN DETAILS

QH101 BASEMENT EQUIPMENT PLAN

QH102 THIRD FLOOR EQUIPMENT PLAN

SPRINKLER

FS001 SPRINKLER SYMBOLS, NOTES, AND ABBREVIATIONS

FD101 BASEMENT PLAN - SPRINKLER DEMOLITION

FD131 LEVEL 03 PLAN - SPRINKLER DEMOLITION

FS101 BASEMENT PLAN - SPRINKLER

FS131 LEVEL 03 PLAN - SPRINKLER

MECHANICAL

MH402 HVAC SCHEDULES

MI301 CAV - HW HEATING

MI302 VAV - HW REHEAT

MI303 VAV - PHARMACY HW REHEAT ROOM PRESSURE CONTROL

MI304 EXHAUST FAN - ON/OFF

MI305 EXHAUST FAN - PHARMACY PRESSURE CONTROL

M-001 MECHANICAL LEGEND, SCHEDULES AND ABBREVIATIONS

MD101 BASEMENT PLAN - HVAC DEMOLITION

MD131 LEVEL 03 PLAN - HVAC DEMOLITION

MD201 BASEMENT PLAN - PIPING DEMOLITION

MD231 LEVEL 03 PLAN - PIPING DEMOLITION

MH101 BASEMENT PLAN - HVAC

OWNER:

Department of Veterans Affairs, Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway Leavenworth KS 66048

Jeanette G. Mathena Jeanette.Mathena@va.gov

913.946.1129

CONTRACTING OFFICER REPRESENTATIVE (COR):

Harry S. Truman Memorial Hospital 800 Hospital Drive Columbia, MO 65201

Daniel P. Schmidt, CMOVAMC Daniel.Schmidt6@va.gov

573-814-6000 x52448

PROJECT ARCHITECT:

Romanyk Consulting Corp.

3308 Preston Road, Suite 350-164 Plano, Texas 75093

Michele M. Kiehl, AIA, LEED AP BD+C Michele.Kiehl@RomanykConsulting.com

855.424.3838 x313

913.908.3280 cell

MECHANICAL ENGINEER:

Romanyk Consulting Corp.

3308 Preston Road, Suite 350-164 Plano, Texas 75093

Arlo Wieczorek, PE Arlo.Wieczorek@RomanykConsulting.com

855-424-3838 x324 319.721.4986

PLUMBING ENGINEER:

Romanyk Consulting Corp.

3308 Preston Road, Suite 350-164 Plano, Texas 75093

Arlo Wieczorek, PE Arlo.Wieczorek@RomanykConsulting.com

855-424-3838 x324 319.721.4986

ELECTRICAL ENGINEER:

Romanyk Consulting Corp.

3308 Preston Road, Suite 350-164 Plano, Texas 75093

Jeffrey Koehler Jeffrey.Koehler@RomanykConsulting.com

855.424.3838 x315

262.930.0903 cell

INTERIOR DESIGNER:

Spellman Brady & Company 8251 Maryland Ave STE 300 St. Louis, MO 63105

Melissa Kenney, IIDA, RID, NCIDQ, LEED AP Mkenney@spellmanbrady.com

314.862.0070 x128 314.369.9241

Revisions: Date:

1i

0 GRID / COLUMN LINE DESIGNATOR

EQUIPMENT NUMBER

DOOR NUMBER

Ga5xFB1

WALL TYPE

WINDOW TYPE

ROOM NAME

ROOM NAME / NUMBER

REVISION TAG

NORTH

NORTH ARROW WITH TRUE

NORTH INDICATION

EGRESS ROUTE ID AND

SECTION LENGTH

ROOM

ROOM OCCUPANCY

150 SF

EGRESS : EGRESS ID

Egress Length

ROOM OCCUPANCY & AREA

ELEVATION NUMBER

SECTION

INTERIOR ELEVATION

ENLARGEMENT,

DETAIL

SPOT ELEVATION

Name Elevation

FLOOR LEVEL &

NAME

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

SHEET KEYNOTE

A101

SIM

EXTERIOR ELEVATION

A-101

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

A101

A101

ANNOTATION DRAWING SYMBOLS

INDEX OF DRAWINGS

202-A101

DISCIPLINE:

G - GENERAL

A - ARCHITECTURE

I - INTERIORS

F- FIRE PROTECTION

P - PLUMBING

M - MECHANICAL

E - ELECTRICAL

T - TELECOM

V - VENTILATION

SHEET TYPE

DESIGNATOR

BUILDING NUMBER

SHEET NUMBER

WITHIN SERIES

ARCHITECTURAL SYMBOLS

LEGEND

CONCRETE/ PRECAST

CONCRETE

SOIL

SAND, EIFS FINISH COAT,

OR CEMENT PLASTER

BRICK

CMU

STONE

FIBERGLASS BATT

INSULATION

EXPANDED POLYSTYRENE

RIGID INSULATION

EXTRUDED POLYSTYRENE

RIGID INSULATION

POLYISOCYANURATE RIGID

INSULATION

GYPSUM BOARD

EXTERIOR GYPSUM

SHEATHING

EXTERIOR CEMENT

BOARD

COATED GLASS MAT

WATER RESISTANT

GYP BD

PLYWOOD

COVER BOARD

MATERIALS

CEILING SYMBOLS

MECHANICAL SUPPLY DIFFUSER

MECHANICAL RETURN GRILLE

MECHANICAL EXHAUST GRILLE

24" X 24" ACOUSTICAL CEILING

PANEL AND GRID

GYPSUM BOARD CEILING OR

SOFFIT

2' x 2' LED FLUORESCENT

FIXTURE - EMERGENCY NIGHT

LIGHT

RECESSED CAN DOWNLIGHT

CEILING ELEVATION A.F.F.X'-X"

EXIT SIGN

LED LIGHT

1' x 4' LED FLUORESCENT

FIXTURE

2' x 4' LED FLUORESCENT

FIXTURE

INDUSTRIAL LUMINAIRE

EMERGENCY LIGHT

2' x 2' LED FLUORESCENT

FIXTURE

OC

NURSE CALL DOME LIGHT WALL

MOUNTED

A

FIRE ALARM AUDIO/VISUAL

NOTIFICATION DEVICE-CEILING

MOUNTED.

CAM

LS

OCCUPANCY SENSOR

A1 A3

DAYLIGHT LEVEL SENSOR

CLOSED CIRCUIT CAMERA (CCTV)

CEILING MOUNTED

N

S SPEAKER

CLOSED CIRCUIT CAMERA (CCTV)CAM

VC VACANCY SENSOR

WAP CEILING INFORMATION OUTLET

FIRE ALARM VISUAL NOTIFICATION

DEVICE - WALL MOUNTED

V1

WALL CONTROL STATIONSW

NURSE CALL STATIONN

SMOKE,FIRE/SMOKE

DAMPER CONTROLLER

ARD

FIRE ALARM MANUAL PULL

STATION

F

FIRE ALARM SMOKE,

SMOKE DAMPER

SD

SD FIRE ALARM DUCT SMOKE

DETECTOR

D DIMMER LED

A FIRE ALARM AUDIO/VISUAL

NOTIFICATION DEVICE- WALL

MOUNTED.

A1 A3

S SWITCH

{LD}

{LS}

LIGHT DIMMER

LIGHT SENSOR

ARCHITECTURAL DRAWING ABBREVIATIONS

A ---------------------

A LABEL CLASS A DOOR

A/C AIR CONDITION

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AB ANCHOR BOLT

ACC ACCESSIBLE

ACS AUTOMATIC CONTROL SYSTEM

ACS DR ACCESS DOOR

ACS PNL ACCESS PANEL

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADMIN ADMINISTRATION

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGGR AGGREGATE

AHU AIR HANDLING UNIT

AIB AIR INFILTRATION BARRIER

ALT ALTERNATE

ALG ALUMINUM AND GLASS

AL ALUMINUM

ALUM ALUMINUM

ANOD ANODIZE

APC ACOUSTICAL PANEL CEILING

APPROX APPROXIMATE

AR AS REQUIRED

ARCH ARCHITECT

ASC ABOVE SUSPENDED CEILING

ASSY ASSEMBLY

ATC ACOUSTICAL TILE CEILING

AVG AVERAGE

AW ARCHITECTURAL WOODWORK

AWT ACOUSTICAL WALL TREATMENT

B ---------------------

B LABEL CLASS B DOOR

BALC BALCONY

BB BASEBOARD

BC BOOKCASE

BD BOARD

BDRY BOUNDARY

BFF BELOW FINISH FLOOR

BHMA BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION

BLDG BUILDING

BLKG BLOCKING

BLT IN BUILT-IN

BN BULLNOSE

BOS BOTTOM OF STEEL

BOT BOTTOM

BP BUILDING PAPER

BRKT BRACKET

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT-UP ROOFING

C ---------------------

C CONC CAST CONCRETE

C LABEL CLASS C DOOR

CAB CABINET

CATW CATWALK

CAV CAVITY

CBB CEMENTITIOUS (BACKER) BOARD

CD CONSTRUCTION DOCUMENTS

CDW CHILLED DRINKING WATER

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CI CAST IRON

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLG DIFF CEILING DIFFUSER

CLG HT CEILING HEIGHT

CLL COLUMN LINE

CLO CLOSET

CLR COLOR

CLRM CLASSROOM

CMU CONCRETE MASONRY UNIT

CNDS CONDENSATE

CDR CARD READER

CO CLEANOUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONC FLR CONCRETE FLOOR

CONF CONFERENCE

CONT CONTINUE

COORD COORDINATE

CORR CORRIDOR

CP CONCRETE PIPE

CPT CARPET

CR CONTROL ROOM

CS CAST STONE

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTR CENTER

CU FT CUBIC FEET

CW CASEMENT WINDOW

D ---------------------

D DEPTH

D LABEL CLASS D DOOR

DBL DOUBLE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DIR DIRECTION

DIST DISTANCE

DOC DOCUMENT

DR DOOR

DS DOWNSPOUT

E ---------------------

E LABEL CLASS E DOOR

EA EACH

EF EACH FACE

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EJ EXPANSION JOINT

ES EACH SIDE

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR

ELEV EQ ELEVATOR EQUIPMENT

ENTR ENTRANCE

EPS EXPANDED POLYSTYRENE BOARD (INSULATION)

EQ EQUAL

EWC ELECTRIC WATER COOLER

EXP EXPOSED

EXT EXTERIOR

EXT EXTINGUISHER

EXT GR EXTERIOR GRADE

F ---------------------

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FAS BD FASCIA BOARD

FC BRK FACE BRICK

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FED FEDERAL

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF INSUL FOIL BACKED INSULATION

FGL FIBERGLASS

FH FIRE HOSE

FHP FULL HEIGHT PARTITION

FIN FINISH

FIN BS FINISH BOTH SIDES

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIXT FIXTURE

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLMT FLUSH MOUNT

FLR FLOOR

FM FACTORY MUTUAL

FOC FACE OF CONCRETE

FOM FACE OF MASONRY

FR FIRE RESISTANT

FRG FIBER REINFORCED GYPSUM

FRMG FRAMING

FRP FIBERGLASS REINFORCED PLASTIC

FRTW FIRE RETARDANT TREATED WOOD

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET

FTG FOOTING

FWC FABRIC WALLCOVERING

G ---------------------

G NATURAL GAS

GALV GALVANIZED

GB GRAB BAR

GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED

GFGI GOVERNMENT FURNISHED INSTALLED BY GOVERNMENT

GFRG GLASS-FIBER-REINFORCED GYPSUM

GLZ GLAZING

GR FL GROUND FLOOR

GSF GROSS SQUARE FEET

GUT GUTTER

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H ---------------------

HAC HOUSE AID KEEPING CLOSET

HB HOSE BIBB

HDPE HIGH DENSITY POLYETHYLENE

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMF HOLLOW METAL FRAME

HORIZ HORIZONTAL

HR HOUR

HT HEIGHT

HVAC HEATING, VENTILATION, AND AIR CONDITIONING

HYDR HYDRAULIC

I ---------------------

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION

INT INTERIOR

ILO IN LIEU OF

ISO ISOLATION

J ---------------------

JAN JANITOR

K ---------------------

KPD KEYPAD

KIT KITCHEN

KPL KICKPLATE

L ---------------------

LAM LAMINATE

LAV LAVATORY

LBR LUMBER

LBS POUND

LDG LANDING

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LIB LIBRARY

LIN LINEAR

LKR LOCKER

LOC LOCATION

LT LIGHT

LVDR LOUVER DOOR

LVR LOUVER

M ---------------------

MACH RM MACHINE ROOM

MATL MATERIAL

MAX MAXIMUM

MC MOISTURE CONTENT

MD METAL DECK

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MEMB MEMBRANE

MF MILL FINISH

MFR MANUFACTURER

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM, MINUTE

MIRR MIRROR

MISC MISCELLANEOUS

MLDG MOLDING (MOULDING)

MO MASONRY OPENING

MOD MODIFY

MB MOISTURE BARRIER

MTG MOUNTING

MTL METAL

MVBL MOVABLE

MWP MEMBRANE WATERPROOFING

N ---------------------

N NORTH

NA NOT APPLICABLE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NP NO PAINT

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

O -------------------

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OFD OVERFLOW DRAIN

OFF OFFICE

OGL OBSCURE GLASS

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPQ OPAQUE

OWSJ OPEN WEB STEEL JOIST

OPR OPERABLE

ORD OVERFLOW ROOF DRAIN

ORIG ORIGINAL

P --------------------

PA PUBLIC ADDRESS

PAR PARAPET

PAT PATTERN

PB PULL BOX

PBD PARTICLEBOARD

PCC PRECAST CONCRETE

PCF POUNDS PER CUBIC FOOT

PCT PERCENT

PERF PERFORATED

PERIM PERIMETER

PH PHASE

PIL PILASTER

PL PROPERTY LINE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLBG PLUMBING

PLG PILING

PLYWD PLYWOOD

PNL PANEL

PP PL PUSH/PULL PLATE

PR PAIR

PRCST PRECAST

PRKG PARKING

PS CONC PRESTRESSED CONCRETE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTDR PAPER TOWEL DISPENSER AND RECEPTACLE

PTN PARTITION

PWR POWER

Q --------------------

QT QUARRY TILE

QTY QUANTITY

R --------------------

RB RESILIENT BASE

RBM REINFORCED BRICK MASONRY

RBR RUBBER

RC REINFORCED CONCRETE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

RDG INS RIGID INSULATION, SOLID

REC RECESSED

REC ROOM RECREATION ROOM

REF REFERENCE

REM REMOVABLE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

REST RESTROOM

RF RESILIENT FLOORING

RFG ROOFING

RH ROOF HATCH

RHR RIGHT HAND REVERSE

RL ROOF LEADER

RLG RAILING

RM ROOM

RO ROUGH OPENING

RSD ROLLING STEEL DOOR

RV ROOF VENT

RVL REVEAL

S --------------------

SB SPLASH BLOCK

SCHED SCHEDULE

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SGL SINGLE

SHT MTL FLASH SHEET METAL (FLASHING)

SHTHG SHEATHING

SHWR SHOWER

SHV SHELVING

SIM SIMILAR

SJ SCORED JOINT

SKLT SKYLIGHT

SLNT SEALANT

SMK SMOKE

SMLS SEAMLESS

SP EL SPOT ELEVATION

SPEC SPECIFICATION

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SST STAINLESS STEEL

ST STAIRS

STD STANDARD

STL JST STEEL JOIST

STL RF DK STEEL ROOF DECK

STOR STORAGE

STR STRINGERS

STRB/HRN STROBE/HORN

SUB FL SUBFLOOR

SV SHEET VINYL

SW SIDEWALK

T --------------------

T TREAD

T/S TUB/SHOWER

TC TERRA COTTA

TD TRENCH DRAIN

TEL TELEPHONE

TEMP TEMPORARY

TER TERRAZZO

TFF TOP OF FINISH FLOOR

THK THICKNESS

TK BD TACKBOARD

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TOF TOP OF FOOTING

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOPO TOPOGRAPHY

TOS TOP OF SLAB

TRANS TRANSOM

TRTD TREATED

TV TELEVISION

SEE OTHER DISCIPLINES FOR

ADDITIONAL ABREVIATIONS

NOTE: NOT ALL MAY BE USED

ARCHITECTURAL SYMBOLS

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V

IS

N

C o lu m b ia C o m p le te U n fi n is h e d S p e c ia lt y C lin ic

/C o lu m b ia U n fi n is h e d S p e c C lin ic

V

.r v t

/2

/2

:2

:1

A

M

Checker Author

589A4-20-155

GI101

589A4 - COLUMBIA, MO

JUNE 25, 2021

01-

ABBREVIATIONS 100% FINAL CONSTRUCTION

DOCUMENTS

COMPLETE UNFINISHED SPECIALTY

CLINIC

ACCESSIBLE SIGNAGE REQS

LETTER AND NUMBER HEIGHTS

TOILET ACCESSORY LEGEND

NOTES

CHARACTER PROPORTIONS:

LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO

BETWEEN 3:5 AND 1:1 AND A STROKE-WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND

1:10, UTILIZING AN UPPER CASE 'X' FOR MEASUREMENT.

CHARACTER HEIGHT:

SEE LETTER AND NUMBER HEIGHT CHART BELOW

*EXCEPTION: CHARACTER HEIGHT SHALL BE 5/8" HIGH MINIMUM FOR BUILDING

DIRECTORIES.

PICTOGRAMS:

WHERE PICTOGRAMS ARE REQUIRED, THEY SHALL HAVE A 6" MINIMUM SIZE

MEASURED AT THE BORDER. WHERE TEXT DESCRIPTORS FOR PICTOGRAMS ARE

REQUIRED, THEY SHALL COMPLY WITH THE TACTILE CHARACTER PROVISIONS OF

RAISED CHARACTERS AND SYMBOLS, BRAILLE, AND LOCATION OF TACTILE

SIGNAGE PORTIONS BELOW.

FINISH AND CONTRAST:

THE CHARACTERS, SYMBOLS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL,

MATTE, OR OTHER NON-GLARE FINISH. CHARACTERS AND BRAILLE, AND LOCATION

OF TACTILE SIGNAGE PORTIONS BELOW. LIGHT BACKGROUND.

RAISED CHARACTERS AND SYMBOLS:

CHARACTERS AND SYMBOLS ON TACTILE SIGNS SHALL BE RAISED 1/32" MINIMUM.

RAISED CHARACTERS AND SYMBOLS SHALL BE IN UPPERCASE CHARACTERS.

RAISED CHARACTERS AND SYMBOLS SHALL BE 5/8" HIGH MINIMUM, AND 2"

MAXIMUM. RAISED CHARACTERS AND SYMBOLS SHALL BE ACCOMPANIED BY

BRAILLE IN ACCORDANCE WITH THE PROVISIONS OUTLINED BELOW.

BRAILLE:

BRAILLE SHALL BE SEPARATED 1/2" MINIMUM FROM THE CORRESPONDING RAISED

CHARACTERS OR SYMBOLS. BRAILLE PROVIDED IN ACCORDANCE WITH THE

REQUIREMENTS FOR ELEVATOR CONTROLS SHALL BE PLACED 3/16" MINIMUM BELOW

THE CORRESPONDING CHARACTERS OR SYMBOLS. BRAILLE SHALL BE GRADE II AND

SHALL CONFORM TO SPECIFICATION #800, NATIONAL LIBRARY SERVICE, LIBRARY OF

CONGRESS.

LOCATION OF TACTILE SIGNAGE:

TACTILE SIGNAGE SHALL BE LOCATED ALONGSIDE THE DOOR ON THE LATCH SIDE

AND SHALL BE MOUNTED AT 60" ABOVE THE ADJACENT FINISHED FLOOR TO THE

CENTERLINE OF THE SIGN. IN LOCATIONS HAVING DOUBLE DOORS, TACTILE SIGNS

SHALL BE MOUNTED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS

NO WALL SPACE ON THE LATCH SIDE OF THE DOOR, INCLUDING DOUBLE LEAF

DOORS, SIGNS SHALL BE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE

ON THE LATCH SIDE OF THE DOOR, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL

BE PLACED ON THE NEAREST ADJACENT WALL.

GENERAL NOTES:

ANY ADDITIONAL TEXT REQUIRED DUE TO LOCAL ORDINANCES (FINES FOR

PARKING IN ACCESSIBLE SPACES, ETC.) SHALL COMPLY WITH THE SIGNAGE

REQUIREMENTS ABOVE.

ALL INTERIOR SIGNAGE WITHIN THE ASC SHALL CONFORM TO THE REQUIREMENTS

OF ADA 2010 AND ANY OTHER STATE OR LOCAL APPLICABLE CODES.

HEIGHT ABOVE FLOOR/ GROUND: MIN. CHARACTER HEIGHT:

GREATER THAN 80" (6'-8") AFF 3"

GREATER THAN 60" (5'-0") AFF BUT LESS THAN 80" (6'-8") AFF 2"

GREATER THAN 48" (4'-0") AFF BUT LESS THAN 60" (5'-0") AFF 1"

A FLOOR MOUNTED TOILET (CFCI)

GB42 42" GRAB BAR (BLOX FURNISHED & INSTALLED)

GB36 36" GRAB BAR (BLOX FURNISHED & INSTALLED)

GB18 18" GRAB BAR (VERTICAL) (BLOX FURNISHED &

INSTALLED)

E MIRROR (BLOX FURNISHED & INSTALLED)

F TOILET PAPER DISPENSER (OFCI)

G ROBE HOOK (CFCI)

H SOAP DISPENSER (OFCI)

H PAPER TOWEL DISPENSER (OFCI)

J SANITARY NAPKIN DISPOSAL (CFCI)

O BABY CHANGING TABLE (CFCI)

P WALL MOUNTED SINK (BLOX FURNISHED &

INSTALLED)

U SURFACE MTD TOILET SEAT COVER DISPENSER

(CFCI)

1. SEE SPECIFICATIONS FOR MANUFACTURERS INFORMATION ON ALL TOILET

ACCESSORIES.

2. ALL SOAP DISPENSERS, PAPER TOWEL DISPENSERS, TOILET PAPER

DISPENSERS & HAND SANITIZER DISPENSERS TO BE OWNER FURNISHED AND

CONTRACTOR INSTALLED. LOCATIONS SHOWN FOR FACILITY.

3. FOR ALL TOILET ROOMS, REFER TO SPECIFICATIONS AND DRAWINGS FOR

PARTITION TYPES & DETAILS AND BLOCKING REQUIREMENTS FOR TOILET

ACCESSORIES.

4. ALL TOILET LOCATIONS, WHETHER NOTED OR NOT, SHALL BE PROVIDED WITH

THE FOLLOWING UNLESS OTHERWISE NOTED:

a) ONE MIRROR

b) ONE TOILET PAPER DISPENSER

c) ONE ROBE HOOK - MOUNTED BEHIND STALL DOORS.

A D

A

T O

H A

N D

L E

MIRROR SOAP DISPENSER PAPER

TOWEL

DISPENSER

TOILET PAPER

DISPENSER

TOILET

PAPER

HOLDER

SANITARY

NAPKIN

DISPOSAL

MIN

1' - 3"

LAVATORY

M

IN

INSULATE EXPOSED

PIPING WITH WHITE

PLASTIC PRE-FITTED

INSULATION

M A

X

MEASURE

TO BOTTOM

OF REFLECTIVE

SURFACE

D

IS

P E

N S

E R

M A

X O

P E

R A

B L E

D

IS

P E

N S

E R

M

A X

T O

O P

E R

A B

L E

M A

X

M

IN

M

IN

FIRE

EXTINGUISHERS

AND CABINETS

7-PEG

COAT RACK

2' - 0"

"MIN

8"

MIN

11"

KNEE AND TOE

CLEARANCES

E

E

SEALANT

PROVIDE ADA

COMPLIANT FAUCET

WITH WRIST BLADE

CONTROLS

M A

X

5" MAX 15" MAX

ACCESS HGT. D.F.

SPOUT LOCATION

M

IN

SPOUT

HEIGHT

STANDING AND

ACCESSIBLE DRINKING

FOUNTAINS

FRONT SIDE

PLAN

ALUM. SEMI-RECESSED CAB.

W/ FULL CLEAR ACRYLIC DOOR

10 LBS

ABC TYPE

BABY CHANGING

TABLE

M A

X

/2

ROBE

HOOK

M A

X

"FIRE EXTINGUISHER" IN

RED LETTERS

G

F

F

(ALT)H

J

C

N O O

P

P

M

IN9

MIN

11"

M

IN

8"

25" MAX

30x48

CLEAR

SPACE

U

M A

X

TOILET

SEAT COVER

DISPENSER

SIGNAGE

(12" BELOW CEILING)

2"

HANDRAIL

PER NFPA 10

PTD (OF/OI)

PUBLIC TLTS

ONLY

SEMI-

RECESSED

WASTE RECP.

S P

O U

T H

G T

S T

A N

D

IN

G H

E

IG

H T

D .F

A C

C E

S S

H

E

IG

H T

D .F

M A

X

NOTE: PROVIDE CANE

DETECTABLE APRON AT

THE STANDING HEIGHT

UNIT

MIN

3' - 6"

MAX

1' - 0"

WATER CLOSET

SIDE WALL

1 1/4" MIN., 2" MAX DIA.

GRAB BAR WITH 1 1/2"

GAP FROM WALL

WATER CLOSET

BACK WALL

TP DISPENSER

MOUNTING AREA

1' - 6"

T .O

G

.B

/2

4' - 6" MIN

MIN

1' - 0"

MIN

2' - 0"

FLUSH CONTROLS

ON OPEN SIDE

M

IN

GB42

GB36

A

A

3' - 4"

/2

GB18

U

CENTER ON

GRAB BAR END

NOTE: GRAB BARS

SHALL BE 33" - 36" TO

TOP OF BAR

MEASURE

TO BOTTOM

OF REFLECTIVE

SURFACE

3' - 0"

6"

6"

8"

MEN WOMEN

NO SMOKING

T O

F

IN

IS

H

E D

F L O

O R

F

IN

IS

H

E D

F L O

O R

T O

T O

F

IN

IS

H

E D

F L O

O R

PROPORTIONS OF THE INTERNATIONAL

SYMBOL OF ACCESSIBILITY

(BRAILLE) (BRAILLE)

INTERIOR SIGNAGE

DOOR FRAME

LATCH SIDE OF

DOOR PANEL

TO TOP OF SIGN

GENERAL NOTES:

PROVIDE INTERIOR SIGNAGE FOR EVERY DOOR/ROOM UNLESS NOTED

OTHERWISE (REFER TO FINISH DRAWINGS).

ALL FINAL ROOM NAMES SHALL BE APPROVED BY ARCHITECT/OWNER PRIOR

TO SIGN FABRIACATION.

AT LOCATIONS WHERE THERE ISN'T AVAILABLE WALL SPACE TO INSTALL THE

INTERIOR SIGNAGE AS INDICATED, OBTAIN ARCHITECT'S INSTRUCTION PRIOR

TO INSTALLATION.

AT LOCATIONS WHERE THERE ISN'T AVAILABLE WALL SPACE, BUT AVAILABLE

WINDOW SPACE, ADHERE INTERIOR SIGNAGE WITH DOUBLE SIDED TAPE TO

PROVIDE A PERMANENT INSTALLATION. PROVIDE A BLANK PANEL OF THE

SAME COLOR, SIZE, AND MATERIAL FOR THE BACK SIDE OF THE SIGN TO BE

INSTALLED ON THE GLASS.

1.

2.

3.

4.

T-SHAPED TURNING SPACE

TURNING RADIUS

ø 5

5' - 0"

2' - 0" 3' - 0"

IF DOOR HAS BOTH

A CLOSER AND LATCH

OTHERWISE THIS = 0"

LATCH APPROACH, PUSH SIDE

Y= 4'-0" MIN IF DOOR HAS

A CLOSER, OTHERWISE Y = 3'-6"

FRONT APPROACH, PUSH SIDE

Y= 4'-6" MIN. IF DOOR HAS

A CLOSER, OTHERWISE

Y = 4'-0" MIN

Y= 4'-0" MIN IF DOOR HAS

BOTH A CLOSER AND LATCH

OTHERWISE Y = 3'-6"

HINGE APPROACH, PUSH SIDE

X= 3'-0" MIN. IF Y= 5'-0"

X= 3'-6" MIN. IF Y= 4'-6"

MIN

2' - 0"

Y M

IN

MIN

1' - 6"

Y X

MIN

2' - 0" Y 1' - 0" Y

1' - 10"

LATCH APPROACH, PULL SIDE FRONT APPROACH, PULL SIDE HINGE APPROACH, PULL SIDE

NTS

TOILET ACCESSORY MOUNTING HEIGHTS

NTS

ACCESSIBLE SIGNAGE DIAGRAMS

NTS

GENERAL - SIGNAGE

NTS

TURNING SPACE

NTS

TYPICAL DOOR APPROACH DETAILS

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V

IS

N

C o lu m b ia C o m p le te U n fi n is h e d S p e c ia lt y C lin ic

/C o lu m b ia U n fi n is h e d S p e c C lin ic

V

.r v t

/2

/2

:2

:1

A

M

MK LJ

589A4-20-155

GI102

589A4 - COLUMBIA, MO

JUNE 25, 2021

01-

ADA INFORMATION 100% FINAL CONSTRUCTION

DOCUMENTS

COMPLETE UNFINISHED SPECIALTY

CODE SUMMARYENERGY SUMMARY

PROPERTY LOCATION:

FILL IN INFORMATION WITH BUILDING LOCATION

ZONING:

LAND USE: LAND USE INFORMATION HERE

ZONING DISTRICT: ZONING INFORMATION HERE

RELEVANT CODES:

· 2012 INTERNATIONAL BUILDING CODE, W/ AMENDMENTS

· 2012 INTERNATIONAL PLUMBING CODE, W/ AMENDMENTS

· 2012 INTERNATIONAL MECHANICAL CODE, W/ AMENDMENTS

· 2014 NATIONAL ELECTRICAL CODE, W/ AMENDMENTS

· 2012 INTERNATIONAL ENERGY CONSERVATION CODE, W/ AMENDMENTS

· 2012 INTERNATIONAL FUEL GAS CODE, W/ AMENDMENTS

· FIRE SAFETY CODE: 2012 NFPA 101 LIFE SAFETY CODE, W/ AMENDMENTS

2012 NFPA 1 FIRE CODE, W/ AMENDMENTS

2010 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE

· ACCESSIBILITY GUIDELINES:

ICC/ANSI A117.1 - 2009

DEPARTMENT OF JUSTICE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN

· DEPARTMENT OF HEALTH REGULATIONS :

2014 FGI GUIDELINES

USE/OCCUPANCY CLASSIFICATION:

B (BUSINESS) - PER 2012 IBC SECTION 304.1

NEW BUSINESS OCCUPANCY PER 2012 NFPA 101 CHAPTER 38

NEW AMBULATORY HEALTH CARE OCCUPANCY PER 2012 NFPA 101 CHAPTER 20

OCCUPANCY SEPARATION:

ALOWABLE PER 2012 IBC SECTION 422.2: ALLOWABLE PER 2012 NFPA 101

TABLE 6.1.14.4.1(A)

FIRE PARTITION PER SECTION 708 SEPARATING MULTIPLE OCCUPANCY BUSINESS

& AMBULATORY HEALTHCARE

AMB. HEALTHCARE FROM ADJACENT SPACES 1-HOUR SEPARATION REQUIRED

PROVIDED:

1-HOUR SEPARATION @ FLOORPLATES BETWEEN BUSINESS ON FLOORS 1 / 3 AND

AMBULATORY HEALTHCARE ON FLOOR 2

1-HOUR FIRE PARTITION SEPARATING AMBULATORY HEALTHCARE FROM PUBLIC

LOBBY ON FLOOR 2

CONSTRUCTION TYPE:

STEEL STRUCTURAL FRAME; OPEN WEB BAR JOISTS; CONCRETE FLOOR SLAB

OVER METAL

DECK; METAL STUD FRAMED EXTERIOR WALLS AND INTERIOR PARTITIONS

II B - NONCOMBUSTIBLE PER 2012 IBC TABLE 601 / SECTION 602.2

II (000) - NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIAL PER 2012 NFPA

101 CHAPTER 8.2.1.2

(REF. NFPA 220, TABLE A.4.1.1 / CHAPTER 4.3)

HEIGHT & AREA LIMITATIONS:

ALLOWABLE PER 2012 IBC TABLE 503: ALLOWABLE PER 2012 NFPA 101

CHAPTER 38.1.6.1 & TABLE 20.1.6.1

TYPE II-B CONSTRUCTION, B USE GROUP NO REQUIREMENTS FOR BUSINESS

OCCUPANCY

4 STORIES (PER 504.2 SPRINKLER HEIGHT INCREASE) TYPE II (000),

AMBULATORY HEALTH CARE OCCUPANCY

69,000 SQFT / STORY (PER 506.3 SPRINKLER AREA INCREASE) 2 OR MORE

STORIES PERMITTED WITH SPRINKLERS

PROVIDED:

4 STORIES @ 21,097 SQFT / STORY

LIFE SAFETY SYSTEMS:

FIRE DETECTION, ALARM, AND COMMUNICATION SYSTEM PROVIDED PER 2012

NFPA 101 CHAPTER 9.6

SUPERVISED AUTOMATIC SPRINKLER SYSTEM PROVIDED PER 2012 NFPA 101

CHAPTER 9.7.1

EXIT ACCESS:

ALLOWABLE PER 2012 IBC SECTION 1014.3: ALLOWABLE PER 2012 IBC SECTION

1016.2

100' COMMON PATH (TABLE 1014.3) 300' TRAVEL DISTANCE (TABLE 1016.2)

ALLOWABLE PER 2012 NFPA 101 CHAPTER 38.2.5.3.1: ALLOWABLE PER 2012 NFPA

101 CHAPTER 38.2.6.3:

100' COMMON PATH (TABLE A.7.6) 300' TRAVEL DISTANCE (TABLE A.7.6)

ALLOWABLE PER 2012 NFPA 101 CHAPTER 20.2.6.1: ALLOWABLE PER 2012 NFPA

101 CHAPTER 20.2.6.2:

100' COMMON PATH (TABLE A.7.6) 200' TRAVEL DISTANCE (TABLE A.7.6)

PROVIDED:

LESS THAN 100' @ BOTH FLOORS (CORE & SHELL ONLY)

[TRAVEL DISTANCE PER PHASE 2 - INTERIOR FIT-OUT TO BE DETERMINED]

EXIT ACCESS CORRIDOR WIDTH:

ALLOWABLE PER IBC 2012 SECTION 1005.3.2:

22.2" = 0.15"/PERSON x # PEOPLE @ FLOOR 1 22.2" = 0.15"/PERSON x # PEOPLE @ FLOOR 2

OR 44" MIN. (TABLE 1018.2)

ALLOWABLE PER NFPA 101 2012 CHAPTER 38.2.3.2:

44"

PROVIDED:

NO CORRIDORS PROVIDED FOR PHASE 1 - CORE & SHELL

CORRIDOR WIDTH TO BE IN EXCESS OF 44" FOR PHASE 2 - INTERIOR FIT-OUT

EXIT ACCESS CORRIDOR RATING:

ALLOWABLE PER 2012 IBC TABLE 1018.1

NO RATING REQUIRED W/ SPRINKLER SYSTEM

ALLOWABLE PER 2012 NFPA 101 CHAPTER 20.3.6.1 & CHAPTER 38.3.6.1(3)

NO RATING REQUIRED W/ SPRINKLER SYSTEM

PROVIDED:

NO RATING

ELEVATOR LOBBY:

NOT REQUIRED PER 2012 IBC SECTION 713.14.1 EXCEPTION 4

ELEVATOR LOBBY NOT REQUIRED WITH SPRINKLERS

EXIT SEPARATION DISTANCE:

ALLOWABLE PER 2012 NFPA 101 SECTION 7.5.1.3.3:

234'-6" DIAGONAL X 1/3 MIN. ALLOWABLE = 78'-2" MIN.

PROVIDED:

212'-4"

EXIT STAIR WIDTH:

ALLOWABLE PER 2012 IBC SECTION 1005.3.1:

205 MAX. OCCUPANTS / STORY @ 0.20" PER OCCUPANT = 41" EGRESS WIDTH

41" EGRESS WIDTH DIVIDED BY TWO STAIRWAYS = 20.5" PER STAIRWAY

REQUIRED 44" MIN. (SECTION 1009.4)

ALLOWABLE PER 2012 NFPA 101 TABLE 7.3.3.1:

205 MAX. OCCUPANTS / STORY @ 0.30" PER OCCUPANT = 61.5" EGRESS WIDTH

61.5" EGRESS WIDTH DIVIDED BY TWO STAIRWAYS = 30.75" PER STAIRWAY

REQUIRED 44" MIN. (TABLE 7.2.2.2.1.2(B) FOR LESS THAN 2,000 PERSONS):

PROVIDED:

48" @ BOTH EGRESS STAIRS

EXIT STAIR ENCLOSURE RATING:

ALLOWABLE PER 2012 IBC SECTION 1022.2

2-HOUR CONNECTING FOUR STORIES OR MORE

ALLOWABLE PER 2012 NFPA 101 CHAPTER A.7.1.3.2.1(3)

2-HOUR CONNECTING FOUR STORIES OR MORE

PROVIDED:

2-HOUR

SHAFT ENCLOSURE RATING:

ALLOWABLE PER 2012 IBC SECTION 713.4

2-HOUR CONNECTING FOUR STORIES OR MORE

ALLOWABLE PER 2012 NFPA 101 CHAPTER 8.6.5(1)

2-HOUR CONNECTING FOUR STORIES OR MORE

PROVIDED:

2-HOUR

AREA OF REFUGE / ACCESSIBLE MEANS OF EGRESS:

PROVIDED PER 2012 IBC SECTION 1007.2.1, 1007.3 EXCEPTIONS 1 & 2, 1007.4

PROVIDED PER 2012 NFPA 101 CHAPTER 7.2.12.1.1 & 7.2.12.2.4

PLUMBING FIXTURE REQUIREMENTS:

ALLOWABLE PER 2012 IBC TABLE 2902.1

FLOOR 1 OCCUPANCY = 74 MEN / 74 WOMEN (148 TOTAL)

WATER CLOSETS REQUIRED = 3 MEN / 3 WOMEN

(EACH GENDER: 1 PER 25 FIRST 50; 1 PER 50 REMAINDER)

LAVATORIES REQUIRED = 2 MEN / 2 WOMEN

(EACH GENDER: 1 PER 40 FIRST 80; 1 PER 80 REMAINDER)

DRINKING FOUNTAINS REQUIRED = 2

(1 PER 100)

SERVICE SINKS REQUIRED = 1

FLOOR 2 OCCUPANCY = 74 MEN / 74 WOMEN (148 TOTAL)

WATER CLOSETS REQUIRED = 3 MEN / 3 WOMEN

(EACH GENDER: 1 PER 25 FIRST 50; 1 PER 50 REMAINDER)

LAVATORIES REQUIRED = 2 MEN / 2 WOMEN

(EACH GENDER: 1 PER 40 FIRST 80; 1 PER 80 REMAINDER)

DRINKING FOUNTAINS REQUIRED = 2

(1 PER 100)

SERVICE SINKS REQUIRED = 1

PROVIDED:

FLOOR 1

WATER CLOSETS = 1 MEN / 1 WOMEN (10 UNISEX PER TENANT BUILD-OUT)

LAVATORIES = 1 MEN / 1 WOMEN (10 UNISEX PER TENANT BUILD-OUT)

DRINKING FOUNTAINS = (2 PER TENANT BUILD-OUT)

SERVICE SINKS = 1

FLOOR 2

WATER CLOSETS = 1 MEN / 1 WOMEN (6 UNISEX PER TENANT BUILD-OUT)

LAVATORIES = 1 MEN / 1 WOMEN (6 UNISEX PER TENANT BUILD-OUT)

DRINKING FOUNTAINS = (2 PER TENANT BUILD-OUT)

SERVICE SINKS = 1

SLAB-ON-GRADE FLOOR ASSEMBLY:

REQUIRED PER IECC 2012 AMENDED TABLE C402.2:

UNHEATED SLAB, R-10 EXTENDING 24" BELOW SLAB

PROVIDED:

R-10 EXTRUDED POLYSTYRENE 2" RIGID INSULATION EXTENDING 24"

MIN. BELOW SLAB

EXTERIOR WALL ASSEMBLY:

REQUIRED PER IECC 2012 AMENDED TABLE C402.2:

METAL-FRAMED BUILDING, R-13 + R-7.5 C.I.

PROVIDED:

R-21 FIBERGLASS BATT 51/2" INSUL. IN STUD CAVITY W/ CONTINUOUS MIN. R-10

EXTRUDED POLYSTYRENE 2" MIN. RIGID EXTERIOR INSULATION

ROOF ASSEMBLY:

REQUIRED PER IECC 2012 AMENDED TABLE 402.2:

INSUL. ENTIRELY ABOVE DECK, R-25 C.I.

PROVIDED:

FLAT ROOF - CONTINUOUS R-25 POLYISOCYANURATE 4" MIN. RIGID INSULATION

FENESTRATION:

REQUIRED PER IECC 2012 AMENDED TABLE C402.3:

FIXED FENESTRATION U-0.38 MAX.

ENTRANCE DOORS U-0.77 MAX.

SHGC (ALL COMPONENTS) 0.40 MAX.

PROVIDED:

FIXED WINDOW UNITS U-0.38 MAX.

FIXED CURTAIN WALL SYSTEM U-0.38 MAX.

ENTRANCE DOORS U-0.77 MAX.

SHGC (ALL COMPONENTS) 0.40 MAX.

NOTE: THESE DRAWINGS DO NOT

INCLUDE IBC BUILDING CODE

INFORMATION

CODE NOTES - BASEMENT FLOOR

1. DRAWING PURPOSE : NFPA CODE COMPLIANCE

2. FACILITY REVIEWED FOR COMPLIANCE WITH THE FOLLOWING CODES:

A. 2018 NFPA 101 LIFE SAFETY CODE

a. CHAPTER 4 - GENERAL

b. CHAPTER 6 - CLASSIFICATION OF OCCUPANCY AND HAZARD CONTENTS

c. CHAPTER 7 - MEANS OF EGRESS

d. CHAPTER 19 - EXISTING HEALTHCARE OCCUPANCY

3. OWNER:

HARRY S. TRUMAN MEMORIAL HOSPITAL

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

PH (573) 814-6000

4. ARCHITECT:

ROMANYK CONSULTING

3308 PRESTON ROAD

SUITE 350-164

PLANO, TEXAS

5. ARCHITECT SEAL: SEE STAMP IN TITLEBLOCK

6. FIRE SERVICE: CITY OF COLUMBIA FIRE DEPARTMENT

7. INSPECTION: JCHO; CITY OF COLUMBIA

8. OCCUPANCY GROUP TYPE:

a. OCCUPANCY 1/ BUILDING 1/ BASEMENT: EXISTING HEALTHCARE OCCUPANCY

9. CONSTRUCTION TYPE:

CONSTRUCTION TYPE II - NFPA TYPE 222, (TABLE 19.1.6.1)

10. BUILDING 1 - OCCUPANCY 1 GROSS FLOOR AREAS - BASEMENT FLOOR AREA ACTUAL: 158,877 SF (TOTAL FLOOR)

6,920 SF (AREA OF WORK)

11. HEIGHT & AREA LIMITATIONS:

ALLOWABLE AREA: UNLIMITED

HEALTH CARE OCCUPANCY:

ALLOWABLE HEIGHT/ 4 OR MORE

STORIES

ACTUAL HEIGHT/STORIES 7 OCCUPIABLE STORIES

12. MINIMUM CONSTRUCTION REQUIREMENTS (A.8.2.1.2):

CONSTRUCTION TYPE II (222)

HEALTHCARE

OCCUPANCY

BEARING WALLS:

A. EXTERIOR 2 HR

B. INTERIOR 2 HR

C. INT/EXT (ROOF ONLY) 1 HR

NON-BEARING WALLS:

A. EXTERIOR 0 HR

B. INTERIOR NON-COMBUSTIBLE

COLUMNS:

A. SUPPORT FLOORS 2 HR

B. SUPPORT ROOF ONLY 1 HR

BEAMS/GIRDER/TRUSSES:

A. EXTERIOR: 2 HR

B. INTERIOR: 1 HR

FLOOR CONSTRUCTION: 2 HR

ROOF CONSTRUCTION: 1 HR

13. ACTIVE FIRE SAFETY FEATURES:

a. AUTOMATIC SUPPRESSION SYSTEMS:

• SPRINKLER SYSTEM (FULLY SPRINKLED)

• AUTOMATIC AIR-HANDLING SHUT-DOWN

b. FIRE ALARM SYSTEM - SIMPLEX, ADDRESSABLE, AUTO DIAL-UP

c. GENERATOR POWERED EMERGENCY LIGHTING, GENERATOR POWERED

d. EXIT LIGHTING.

e. PORTABLE EXTINGUISHERS

f. SMOKE DETECTORS AT ALL CORRIDORS, ALL SMOKE DOORS AND MISC

AREAS AS REQ'D (ALSO IN SOME DUCTS)

14. WATER SUPPLY: CITY OF COLUMBIA

15. SPRINKLERS: FULLY SPRINKLERED

16. TOTAL OCCUPANTS

TABLE 7.3.1.2 OCCUPANT LOAD FACTOR

USE (FT2 /PERSON)

HEALTHCARE USE

INPATIENT TREATMENT DEPARTMENTS 240

SLEEPING DEPARTMENTS 120

AMBULATORY HEALTH CARE 150

OCCUPANT LOAD = FLOOR AREA/OCCUPANT LOAD FACTOR (TABLE 7.3.1.2)

BUILDING 1

BASEMENT FLOOR (AREA OF WORK): 6,920/150 = 46" (MEANS OF EGRESS WIDTH CANNOT BE LOWER THAN THIS)

17. MEANS OF EGRESS: TWO MEANS OF EGRESS, AS A MINIMUM REQUIRED (4.5.3.1).

ACTUAL MEANS OF EGRESS (BASEMENT FLOOR): 2 MEANS OF EGRESS

18. DOOR OPENINGS IN MEANS OF EGRESS: SHALL BE NO LESS THAN

32" IN CLEAR WIDTH (7.2.1.2.3.2). DOOR OPENINGS IN PROJECT ARE 42".

19. DEAD END CORRIDORS: DEAD END CORRIDORS SHALL NOT EXCEED 30 FEET (TABLE A.7.6)

ACTUAL PROJECT DEAD END CORRIDOR (BASEMENT FLOOR) = 24 FEET.

20. TABLE 7.3.3.1 CAPACITY FACTORS: STAIRWAY (WIDTH/PERSON), HEALTHCARE,

SPRINKLERED = .2 INCHES (LEVEL COMPONENTS AND RAMPS)

21. CORRIDOR WIDTH: AISLES, CORRIDORS, AND RAMPS IN ADJUNCT AREAS NOT INTENDED

FOR THE HOUSING, TREATMENT, OR USE OF INPATIENTS SHALL BE NOT LESS THAN

44 INCHES IN CLEAR AND UNOBSTRUCTED WIDTH (19.2.3.4).

ACTUAL CORRIDOR WIDTH (2ND FLOOR): 72 INCHES (MIN.)

22. NUMBER OF EXITS FOR EACH STORY: NOT LESS THAN TWO EXITS SHALL BE PROVIDED ON

EACH STORY 19.2.4.2). ACTUAL PROJECT EXITS = 2.

23. TRAVEL DISTANCE TO EXITS= THE TRAVEL DISTANCE BETWEEN ANY POINT IN A ROOM AND AN EXIT SHALL NOT EXCEED 150 FEET(19.2.6.2.1). ACTUAL TRAVEL DISTANCE 147 FEET (BASEMENT FLOOR).

24. TABLE A.7.6 COMMON PATH, DEAD-END, AND TRAVEL DISTANCE LIMITS (BY OCCUPANCY)

TYPE OF OCCUPANCY COMMON PATH LIMIT DEAD END LIMIT TRAVEL DISTANCE LIMIT

(SPRINKLERED) (SPRINKLERED) (SPRINKLERED)

EXISTING HEALTH CARE NO REQUIREMENT 30 FEET 200 FEET

CODE NOTES - 3RD FLOOR

1. DRAWING PURPOSE : NFPA CODE COMPLIANCE

2. FACILITY REVIEWED FOR COMPLIANCE WITH THE FOLLOWING CODES:

A. 2018 NFPA 101 LIFE SAFETY CODE

a. CHAPTER 4 - GENERAL

b. CHAPTER 6 - CLASSIFICATION OF OCCUPANCY AND HAZARD CONTENTS

c. CHAPTER 7 - MEANS OF EGRESS

d. CHAPTER 19 - EXISTING HEALTHCARE OCCUPANCY

3. OWNER:

HARRY S. TRUMAN MEMORIAL HOSPITAL

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

PH (573) 814-6000

4. ARCHITECT:

ROMANYK CONSULTING

3308 PRESTON ROAD

SUITE 350-164

PLANO, TEXAS

5. ARCHITECT SEAL: SEE STAMP AREA IN TITLEBLOCK

6. FIRE SERVICE: CITY OF COLUMBIA FIRE DEPARTMENT

7. INSPECTION: TJC; CITY OF COLUMBIA

8. OCCUPANCY GROUP TYPE: OCCUPANCY 1/ BUILDING 1/ THIRD FLOOR: EXISTING HEALTHCARE OCCUPANCY

9. CONSTRUCTION TYPE: CONSTRUCTION TYPE II - NFPA TYPE 222, (TABLE 19.1.6.1)

10. BUILDING GROSS FLOOR AREA: 3RD FLOOR AREA: 26,865 SF (TOTAL FLOOR AREA)

6,490 SF (AREA OF WORK)

11. HEIGHT & AREA LIMITATIONS:

ALLOWABLE AREA: UNLIMITED

HEALTH CARE OCCUPANCY:

ALLOWABLE HEIGHT/ 4 OR MORE

STORIES

ACTUAL HEIGHT/STORIES 7 OCCUPIABLE STORIES

12. MINIMUM CONSTRUCTION REQUIREMENTS (A.8.2.1.2):

HEALTHCARE

OCCUPANCY

CONSTRUCTION TYPE II (222)

BEARING WALLS:

A. EXTERIOR 2 HR

B. INTERIOR 2 HR

C. INT/EXT (ROOF ONLY) 1 HR

NON-BEARING WALLS:

A. EXTERIOR 0 HR

B. INTERIOR NON-COMBUSTIBLE

COLUMNS:

A. SUPPORT FLOORS 2 HR

B. SUPPORT ROOF ONLY 1 HR

BEAMS/GIRDER/TRUSSES:

A. EXTERIOR: 2 HR

B. INTERIOR: 1 HR

FLOOR CONSTRUCTION: 2 HR

ROOF CONSTRUCTION: 1 HR

13. ACTIVE FIRE SAFETY FEATURES:

a. AUTOMATIC SUPPRESSION SYSTEMS:

• SPRINKLER SYSTEM (FULLY SPRINKLED)

• AUTOMATIC AIR-HANDLING SHUT-DOWN

b. FIRE ALARM SYSTEM - SIMPLEX, ADDRESSABLE, AUTO DIAL-UP

c. GENERATOR POWERED EMERGENCY LIGHTING

d. EXIT LIGHTING.

e. PORTABLE EXTINGUISHERS

f. SMOKE DETECTORS AT ALL CORRIDORS, ALL SMOKE DOORS AND

AREAS AS REQ'D.

14. WATER SUPPLY: CITY OF COLUMBIA

15. SPRINKLERS: FULLY SPRINKLERED

16. TOTAL OCCUPANTS

TABLE 7.3.1.2 OCCUPANT LOAD FACTOR

USE (FT2 /PERSON)

HEALTHCARE USE

INPATIENT TREATMENT DEPARTMENTS 240

SLEEPING DEPARTMENTS 120

AMBULATORY HEALTH CARE 150

OCCUPANT LOAD = FLOOR AREA/OCCUPANT LOAD FACTOR (TABLE 7.3.1.2)

BUILDING 1

4TH FLOOR (AREA OF WORK): 6,490/150 = 43 TOTAL OCCUPANTS

17. EXIT WIDTH: TABLE 7.3.3.1 CAPACITY FACTORS

EXIT WIDTH STAIRS: 34 OCCUPANTS X.3 INCHES = 10.2" (SCOPE OF WORK)

EXIT WIDTH LEVEL COMPONENTS: 34 X .2 INCHES = 6.8" (SCOPE OF WORK)

18. MEANS OF EGRESS: MINIMUM REQUIRED TWO MEANS OF EGRESS (4.5.3.1)

ACTUAL MEANS OF EGRESS (3RD FLOOR): 2 MEANS OF EGRESS

19. DOOR OPENINGS IN MEANS OF EGRESS: SHALL BE NO LESS THAN 32" IN CLEAR WIDTH (7.2.1.2.3.2).

DOOR OPENINGS IN PROJECT ARE 42" MINIMUM.

20. DEAD END CORRIDORS: DEAD END CORRIDORS SHALL NOT EXCEED 30 FEET. (TABLE A.7.6)

ACTUAL PROJECT DEAD END CORRIDOR (3RD FLOOR) = 25'

21. TABLE 7.3.3.1 CAPACITY FACTORS: STAIRWAY (WIDTH/PERSON), HEALTHCARE,

SPRINKLERED = .2 INCHES (LEVEL COMPONENTS AND RAMPS)

22. CORRIDOR WIDTH: AISLES, CORRIDORS, AND RAMPS IN ADJUNCT AREAS NOT INTENDED

FOR THE HOUSING, TREATMENT, OR USE OF INPATIENTS SHALL BE NOT LESS THAN

44 INCHES IN CLEAR AND UNOBSTRUCTED WIDTH (19.2.3.4).

ACTUAL CORRIDOR WIDTH (3RD FLOOR): 72"

23. NUMBER OF EXITS FOR EACH STORY: NOT LESS THAN TWO EXITS SHALL BE PROVIDED ON

EACH STORY 19.2.4.2). ACTUAL PROJECT EXITS = 2.

24. TRAVEL DISTANCE TO EXITS: THE TRAVEL DISTANCE BETWEEN ANY POINT IN A ROOM AND

AN EXIT SHALL NOT EXCEED 150 FEET(19.2.6.2.1). 19.2.6.2.2

THE MAXIMUM TRAVEL DISTANCE SPECIFIED IN 19.2.6.2.1

SHALL BE PERMITTED TO INCREASE BY 50 FEET IN BUILDINGS

PROTECTED BY AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER

SYSTEM IN ACCORDANCE WITH 19.3.5.7.

ACTUAL MAX TRAVEL DISTANCE: 194'- 2" (3RD FLOOR).

25. TABLE A.7.6 COMMON PATH, DEAD-END, AND TRAVEL DISTANCE LIMITS (BY OCCUPANCY)

TYPE OF OCCUPANCY COMMON PATH LIMIT DEAD END LIMIT TRAVEL DISTANCE LIMIT

(SPRINKLERED) (SPRINKLERED) (SPRINKLERED)

EXISTING NO REQUIREMENT 30 FEET 200 FEET

NOTE: THESE DRAWINGS DO NOT

INCLUDE IBC BUILDING CODE

INFORMATION

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V

IS

N

C o lu m b ia C o m p le te U n fi n is h e d S p e c ia lt y C lin ic

/C o lu m b ia U n fi n is h e d S p e c C lin ic

V

.r v t

/2

/2

:2

:2

A

M

MK LJ

589A4-20-155

GI103

589A4 - COLUMBIA, MO

JUNE 25, 2021

01-

BUILDING CODE 100% FINAL CONSTRUCTION

DOCUMENTS

COMPLETE UNFINISHED SPECIALTY

LIFE SAFETY NOTES

FE

FEC

LIFE SAFETY LEGEND

BASEMENT FLOOR KEY PLAN

AREA OF

WORK

H H

6.3

6.3

5.6

5.6

GG

FF

10.6

10.6

11.5

11.5 E.1

E.1E

E

D D

C C

B B

A A

GRAY AREA NOT IN

PROJECT SCOPE

E001

PHARMACY

FILLING

ASSEMBLY

E001D

TEAM

WORK

AREA

E001C

OFFICE 1

E001B

OFFICE 2

E001A

EXISTING

NARCOTIC

VAULT

SECURED DISPENSING /

STORAGE, INPATIENT

E001E

E001L

POS ISO

ANTEROOM

E001H

POS ISO

NON-HD

BUFFER

E001F

STORAGE

E001J

NEG ISO

HAZ

BUFFER

E001K

NEG HD

STORAGE

E001G

EXISTING

STAIR #11

46"

247/2

24.6"

BLDG 1 - OCCUPANCY 1 - BASEMENT =

158,877 SF (AREA OF WORK)

OCCUPANCY TYPE - BUSINESS

TYPE II (222) CONSTRUCTION

TOTAL OCCUPANTS = 1060

FULLY SPRINKLERED

2 3/4"5 7/16"

TRAVEL DISTANCE: 105' - 0"

TRAVEL DISTANCE: 127' - 4"

TEMPORARY CONSTRUCTION

BARRIER WITH 3'0" x 7'0" FIRE RATED

PARTITION

TEMPORARY CONSTRUCTION

BARRIER

SMOKE

COMPARTMENT #0-0

17000SF

80"

24.8"

247/2

TRAVEL DISTANCE: 63' - 6"

T R

A V

E L D

IS

T

A N

C E

EXIT

COMPLIANCE NOTES PER NFPA

3.9.3.2.1 & 9.7.1.1 (2)

HAZARDOUS AREAS IN FULLY

SPRINKLERED BUILDINGS ARE NOT

REQUIRED TO BE PROTECTED BY FIRE

BARRIERS.

COMPLIANCE NOTES PER NFPA 7.3.13

BUSINESS OCCUPANCY LOAD FACTOR

150 158,877 / 150 = 1060 OCC.

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13

AND IS PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE

DETECTION SYSTEM.

3. REFER TO THIS DRAWING FOR MEANS OF EGRESS

4. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

5. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE

MARSHAL.

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER

FDC

F

L

L

D

MHO

FACP

FAAP

FIRE DEPARTMENT CONNECTION

EXIT

ILLUMINATED EXIT SIGN

FIRE ALARM - MANUAL PULL STATION

FIRE ALARM - STROBE / CHIME

FIRE ALARM - STROBE

SMOKE DETECTOR

MAGNETIC HOLD OPEN

FIRE ALARM CONTROL PANEL

FIRE ALARM ANUNCIATOR PANEL

EXTERIOR EMERGENCY LIGHTING

TRAVEL

PATH

STARTING

LOCATION

TD = XX

TRAVEL DISTANCE

NO. OF OCC./

NO. OF EXITS

ACTUAL

EXIT

WIDTH

OCC.

LOAD

FACTOR

FACP

FSA

FAA

FIRE ALARM CONTROL PANEL

FIRE SYSTEM ANNUNCIATOR ALARM

ANNUNCIATOR PANEL

LIFE SAFETY SYMBOLS

10/1

2"

34"

1:50

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

NEW

PARTITION KEY

NFPA

101-2015

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER

(FIRE WALL IN IBC)

2 HR 90 MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

90 MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

2 HR 90 MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)1 HR

2 HR

60 MIN

90 MIN

HAZ./INCIDENTAL USE

FIRE BARRIER

45 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS (SPRINKLERED)

NR

SELF OR AUTO

CLOSING

SUBDIVIDING SPACES

SMOKE BARRIER (I-2 OCCUPANCY)

20 MIN

1/2

HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

VERT. OPG. (SHAFT)

FIRE BARRIER

60 MIN

[D]

1 HR

2 HR

60 MIN

90 MIN

EXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

8.7

NFPA 6.1.14.4.1

18.1.3.5.1 19.1.3.5.1

NFPA 7.2.A.3.1 (1)

NFPA 18.1.3.8/

19.1.3.8 18.2.2.5/19.2.25 7.1.3.2.1

NFPA 19.3.1.1

NFPA 8.6.2

8.6.5

NFPA 18.3.2.1.2

NFPA 8.4.1.1

19.3.2.1

NFPA 8.4.2 (3)

18.3.2.1.3 19.3.2.1.2

NFPA 8.5.2

18.3.7.3 19.3.7.3

NFPA 8.4.2

18.2.5.7.1.4 19.2.5.7.1.1

NFPA 8.4.2

18.3.6.2 19.3.6.2

21.3.6 39.3.6

NFPA 19.3.1.1

19.2.2.7 8.6.2 8.6.5(3) & 2

NFPA 7.2.6

19.2.2.7 18.2.2.7

NFPA 221

8.2.1.3

EXIST SOL.

CORE WD.

NFPA 7.2.1.4.1

7.2.4.3.7 8.3.4 18.2.2.5.3,4,5,6,7 19.2.2.5,3,4

8.3.4.2 TBL

18.4.4.7.2.2

7.1.3.2.9 (9)

NFPA 8.3.4.2 TBL

19.3.2.1.3,5

NFPA 8.3.4.2 TBL

8.5.4 18.3.7.8

NFPA 8.3.4.2 TBL

8.3.4.2 TBL

8.3.4.2 TBL

NFPA 8.3.4.2 TBL

8.3.4.2 8.4.3 19.3.2.1.4,3,5

8.4.3

8.4.3 18.3.6.4.1 19.3.6.4.1

N/A

FIRE

90 MIN

FIRE

90 MIN

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLOWED

NFPA 90

8.3.5.7 9.2.1

NFPA 8.3.5.7

9.2.1 7.2.4.3.5

N/A

8.5.5.2 18.3.7.3(2) 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4.1 8.4.6.2

8.4.4.1 8.4.6.2

8.4.4.1 8.4.6.2 18.3.6.4.1

N/A

WALL

RATING

RATED UL

ASSEMBLIES

2 HR

1 HR

1 HR

NR-

RESIST

SMK

NR

NR-

RESIST

SMK

NR

8.3

UL U412

UL U419

UL U412

UL U419

UL U412

UL U419

UL U412

UL U419

UL U415 (A)

UL U412

UL U419

UL U415 (A)

UL U412

UL U419

UL U412

UL U419

UL U415 (A)

NR

SELF OR AUTO

CLOSING

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR ONLY

NFPA 90

8.3.5.7 9.2.1

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

NORTH

FULLY SPRINKLERED

B

IM

/V

IS

N

C o lu m b ia C o m p le te U n fi n is h e d S p e c ia lt y C lin ic

/C o lu m b ia U n fi n is h e d S p e c C lin ic

V

.r v t

/2

/2

:2

:2

A

M

MK LJ

589A4-20-155

GI104

589A4 - COLUMBIA, MO

JUNE 25, 2021

01-

BASEMENT LIFE SAFETY PLAN 100% FINAL CONSTRUCTION

DOCUMENTS

COMPLETE UNFINISHED SPECIALTY

CLINIC

1" = 10'-0"

BASEMENT OVERALL FLOOR PLAN

LIFE SAFETY NOTES

FE

FEC

LIFE SAFETY LEGEND

DN

DN

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13

AND IS PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE

DETECTION SYSTEM.

3. REFER TO THIS DRAWING FOR MEANS OF EGRESS

4. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

5. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE

MARSHAL.

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER

FDC

F

L

L

D

MHO

FACP

FAAP

FIRE DEPARTMENT CONNECTION

EXIT

ILLUMINATED EXIT SIGN

FIRE ALARM - MANUAL PULL STATION

FIRE ALARM - STROBE / CHIME

FIRE ALARM - STROBE

SMOKE DETECTOR

MAGNETIC HOLD OPEN

FIRE ALARM CONTROL PANEL

FIRE ALARM ANUNCIATOR PANEL

EXTERIOR EMERGENCY LIGHTING

THIRD FLOOR KEY PLAN

AREA OF

WORK

H H

6.3

6.3

5.6

5.6

GG

FF

10.6

10.6

11.5

11.5 E.1

E.1E

E

D D

C C

B B

ANTEROOM

F359

NON-HAZARDOUS IV PREP

F361

F360

HAZARDOUS

IV

PREP/STORAGE

F364

MED.

ROOM

F362

CLEAN

DISPATCH

F363

SOILED

DISPATCH

TOILET

F365

F374

NURSE

STATION

F386

INFUSION

BAY

F372

INFUSION

BAY

F371

INFUSION

BAY

F375

INFUSION

BAY

F376

INFUSION

BAY

F377

INFUSION

BAY

F378

INFUSION

BAY

F380

PRIVATE

INFUSION

F381

PRIVATE

INFUSION

TOILET

F382

E310

INTAKE

F389

EXAM

ROOM

F391

EXAM

ROOM

F392

EXAM

ROOM

F393

EXAM

ROOM

WHEELCHAIR STORAGE

ALCOVE

F390

F385

PATIENT

TOILET

NOURISH

F383

CORRIDOR

F373

CORRIDOR

F358

F352

EXAM

ROOM

F353

PROVIDERS

ROOM SWAMP

F354 F355

PROVIDERS

ROOM

F356

NURSE

NAVIGATOR

F357

WORK

ROOM

F366

INFUSION

BAY

F367

INFUSION

BAY

F368

INFUSION

BAY

EXISTING OUTDOOR

GARDEN

F370

F379

EQUIPMENT

ALCOVE

E303

WORK

AREA

RECEPTION

E302

HEM/ONC WAITING

E301

EXISTING CORRIDOR

F394

F369

INFUSION

BAY

GRAY AREA NOT IN PROJECT

SCOPE

EXISTING

SMOKE

COMP 3-7

7219 SF

EXISTING

SMOKE

COMP 3-6

18819 SF

STAIR #11

F395

TEMPORARY CONSTRUCTION

BARRIER

TRAVEL DISTANCE: 105' - 9"

TRAVEL DISTANCE: 194' - 2 "

TRAVEL DISTANCE: 123' - 11"

TEMPORARY CONSTRUCTION

BARRIER

BLDG 1 -…