This document is a set of architectural and life safety plans for the renovation of Domiciliary Building 8 at the Hot Springs VA Medical Center. The project involves a comprehensive renovation of a multi-story building with basement, first, and second floors, designed to meet VA construction and life safety code requirements. The building will be fully sprinklered and will have a Type V (111) construction classification, with an existing historic building designation.
The plans detail the renovation of residential board and care spaces, including multiple two-bed and one-bed bedrooms, toilets, storage areas, corridors, and support spaces. The total building area is 14,087 square feet, with each floor measuring approximately 4,475 square feet. Key design features include active fire safety systems such as smoke detectors, emergency lighting, fire alarm systems, and portable extinguishers. The design team includes Stone Group Architects, Albertson Engineering, and West Plains Engineering, with the project being managed by the VA Office of Construction and Facilities Management located in Hot Springs, South Dakota.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT INFORMATION:
1. CONSTRUCTION PURPOSE: RENOVATION
2. REASON FOR SUBMITTAL: RENOVATION
3. I CERTIFY THAT TO THE BEST OF OUR KNOWLEDGE THE SUBMITTED PLANS FOR THE
ABOVE-REFERENCED PROJECT COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING:
NFPA 101-18 (AND ALL REFERENCED DOCUMENTS)
2018 INTERNATIONAL MECHANICAL CODE (IMC)
2015 UNIFORM PLUMBING CODE (UPC)
2017 NATIONAL ELECTRICAL CODE (NFPA-70)
2018 LIFE SAFETY CODE (NFPA-101)
2015 ABA ACCESSIBILITY STANDARDS
BARRIER FREE DESIGN
2018 IBC WITH LOCAL AMENDMENTS
ASHRAE STANDARD 90.1 (2007)
ASHRAE 62.1 (2007)
4. LOCATION OF ANY ANTICIPATED FUTURE ADDITIONS: UNKNOWN
5. OWNER:
DEPARTMENT OF VETERANS AFFAIRS
OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT
500 NORTH 5TH STREET
HOT SPRINGS, SD 57747
6. DESIGN TEAM:
STONE GROUP ARCHITECTS - 605-271-1144
600 E 7TH STREET - SIOUX FALLS, SD 57103
CONTACT: TODD STONE - TODD.STONE@STONEGROUPARCH.COM
ALBERTSON ENGINEERDING - 651-343-9606
3202 W MAIN ST, SUITE C - RAPID CITY, SD 57702
CONTACT: DAVID LEPPERT (STRUCTURAL) - DAVID@ALBERTSONENGINEERING.COM
WEST PLAINS ENGINEERING - 605-348-7455
1750 RAND ROAD - RAPID CITY, SD 57702
CONTACT:
MIKE SIGMAN (ELECTRICAL) - MIKE.SIGMAN@WESTPLAINSENGINEERING.COM
MICHAEL HEINRICH (MECHANICAL) - MICHAEL.HEINRICH@WESTPLAINSENGINEERING.COM
7. ARCHITECTS SEAL: SEE STAMP AT BOTTOM
8. FIRE SERVICE: HOT SPRINGS FIRE DEPARTMENT
9. INSPECTION: VISN SAFETY OFFICER
10. OCCUPANCY GROUP TYPE: RESIDENTIAL BOARD AND CARE
BUSINESS
CHANGE OF OCCUPANCY- 1ST AND 2ND FLOOR (NO)
MIXED OCCUPANCIES - PROPOSED NEW CONSTRUCTION (YES)
2ND- RESIDENTIAL BOARD AND CARE
1ST- RESIDENTIAL BOARD AND CARE
BASEMENT- BUSINESS
11. CONSTRUCTION TYPE: TYPE V (111) FULLY SPRINKLERED
HISTORIC BUILDING: YES
A. ALLOWABLE AREA PER FLOOR: NO CHANGE
ACTUAL AREA PER FLOOR
ATTIC - MECHANICAL: 3,900 SF
SECOND FLOOR: 4,475 SF
ARCADE LOBBY UL: 331 SF
FIRST FLOOR: 4,475 SF
ARCADE LOBBY LL: 331 SF
BASEMENT: 4,475 SF
TOTAL: 14,087 SF
B. BUILDING HEIGHT: NO CHANGE
ACTUAL BUILDING HEIGHT: 48'
STORIES: 2 W/ BASEMENT
12. ACTIVE FIRE SAFETY SYSTEMS
(a) SMOKE DETECTORS THROUGHOUT
(b) GENERATOR POWERED EMERGENCY LIGHTING
(c) BATTERY POWERED EXIT LIGHTING
(d) HOOD SUPPRESSION SYSTEM
(e) PORTABLE EXTINGUISHERS
(f) AUTOMATIC AIR-HANDLING SHUT-DOWN
(g) FIRE ALARM SYSTEM
13. WATER SUPPLY: NATURAL SPRING
14. SEWAGE TREATMENT: CITY OF HOT SPRINGS
15. HANDICAP PROVISIONS: ACCESSIBLE ROUTE
LAVATORIES AND SIGNAGE
16. OCCUPATIONAL LOAD:
OUTPATIENT INSTITUTIONAL: 150 SF/PERSON GROSS
EGRESS CAPACITY:
STAIRWAY: .3 IN./PERSON
DOOR: .2 IN./PERSON
CODE INFORMATION
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD
STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE INFORMATION ON THE
TECHNICAL INFORMATION LIBRARY (TIL)
• INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA
DESIGN DOCUMENTS)
• 2018 NFPA 101 LIFE SAFETY CODE
• 2018 IBC
• NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
• VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• NATIONAL ELECTRICAL CODE (NEC)
• INTERNATIONAL PLUMBING CODE (IPC)
• ASME BOILER AND PRESSURE VESSEL CODE
• ASME CODE FOR PRESSURE PIPING
• ARCHITECTURAL BARRIER ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA
SUPPLEMENT, BARRIER FREE DESIGN GUIDE (PG-18-13)
• VA FIRE PROTECTION DESIGN MANUAL
NOTE: ALL WORK IS TO BE PERFORMED TO THE LATEST EDITION OF THE FOLLOWING CODES, ORDINANCES, AND LAWS WHICH INCLUDE, BUT ARE NOT LIMITED TO: A. CONTRACTOR IS NOT AUTHORIZED TO SCALE CONSTRUCTION DOCUMENTS. ARCHITECT IS TO BE NOTIFIED IN THE EVENT A DISCREPANCY IS FOUND IN EITHER SPECIFICATIONS OR CONTRACT
DOCUMENTS AT THE EARLIEST PRACTICAL OPPORTUNITY.
B. GENERAL CONTRACTOR SHALL OBSERVE ALL REGULATIONS IMPOSED BY GOVERNING BODIES.
C. CONSTRUCTION SHALL PROCEED IN AN ORDERLY AND CONTINUOUS FASHION IN ACCORDANCE WITH
THE INTERNATIONAL BUILDING CODES AND ALL OTHER APPLICABLE CODES.
D. THE CONTRACTOR SHALL CONTAIN ALL CONSTRUCTION ACTIVITY, INCLUDING STORAGE OF MATERIAL
AND EQUIPMENT, WITHIN THE CONSTRUCTION LIMITS, AT ALL TIMES BEING RESPONSIBLE FOR AND
ABIDING BY RULES AND REGULATIONS OF THE OWNER.
E. GENERAL CONTRACTOR TO BE RESPONSIBLE FOR REPAIRING ANY AND ALL SURFACES DAMAGED BY
HIMSELF OR SUBCONTRACTORS UNDER HIS CONTROL. REPAIRS ARE TO MATCH EXISTING
MATERIALS AND MUST BE ACCEPTABLE TO OWNER.
F. ADEQUATELY PATCH/REPAIR TO MATCH ADJACENT CONSTRUCTION, ALL BUILDING STRUCTURES, COMPONENTS, AND UTILITIES WHICH ARE DISTURBED AND REQUIRE REPAIR AS A RESULT OF WORK
PERFORMED UNDER THIS CONTRACT.
G. ALL FLOOR TRANSITIONS BETWEEN DIFFERENT MATERIALS SHALL BE SMOOTH AND FLUSH (MAXIMUM
SLOPE = 1/8" PER FOOT).
H. GENERAL CONTRACTOR SHALL REMOVE ALL CONSTRUCTION DEBRIS FROM JOBSITE. ALL
CONSTRUCTION DEBRIS SHALL BE CONTAINED INSIDE CONSTRUCTION LIMITS.
I. ALL WALLS WITH ITEMS SUCH AS GRAB BARS, TOILET ACCESSORIES, WOOD TRIM, SHELVING, CASEWORK, ETC. SHALL BE REINFORCED WITH CONCEALED, FIRE TREATED WOOD BLOCKING OR
METAL STUD BLOCKING. (GENERAL CONTRACTOR TO INSTALL BLOCKING TYP.)
J. BUILDING 5 WILL REMAIN OCCUPIED THROUGHOUT THE CONSTRUCTION PERIOD. THE CONTRACTOR SHALL TAKE EVERY NECESSARY PRECAUTION TO ENSURE THE UNINTERRUPTED OPERATION OF THE FACILITY, STAFF, PATIENTS AND VISITORS. DISRUPTION TO ADJACENT DEPARTMENTS AS WELL AS
DEPARTMENTS ON FLOORS ABOVE OR BELOW SHALL BE COORDINATED WITH THE FACILITY
CONTRACT OFFICER. THE CONTRACTOR SHALL COORDINATE ALL WORK, CONSTRUCTION, PATHWAYS, ELEVATOR USAGE, AND UTILITY INTERRUPTION WITH THE OWNER.
K. CONTRACTOR TO EXERCISE ALL PRECAUTIONS TO PROVIDE FOR STAFF, PATIENTS, VISITORS, AND WORKMEN'S SAFETY DURING THE PERFORMANCE OF THIS CONTRACT PER EPA, OSHA, AND OTHER
APPLICABLE CODES, STANDARDS, AND REGULATIONS.
L. THE CONTRACTOR SHALL MAINTAIN & KEEP BARRIER FREE THE EXISTING MEANS OF EGRESS.
M. ALL GYPSUM BOARD TO BE MOISTURE/MOLD RESISTANT TYPE X.
N. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION OF TEMPORARY PARTITIONS AND
TEMPORARY VENTILATION SYSTEMS AS REQUIRED TO PREVENT THE SPREAD OF DUST FROM THE
CONSTRUCTION AREA TO OCCUPIED AREAS OF THE BUILDING. OCCUPIED AREAS SHALL REMAIN DUST FREE THROUGHOUT THE CONSTRUCTION. THE CONTRACTOR SHALL MAINTAIN THE AFFECTED AREAS
OF THE BUILDING (INCLUDING MATERIAL TRANSPORT ROUTES) CLEAN AND DUST FREE.
O. ALL WOOD USED IN WALL CONSTRUCTION SHALL BE FIRE-RETARDANT-TREATED LUMBER.
P. ALL WRITTEN CORRESPONDENCE WILL BE TRANSMITTED FROM SUBCONTRACTOR THROUGH
GENERAL CONTRACTOR THROUGH ARCHITECT TO OWNER. ALL PARTIES CORRESPONDENCE ARE TO
RECEIVE WRITTEN AND SIGNED COPIES OF SUCH. NO VERBAL AGREEMENTS AFFECTING COST OR
ALTERNATIVE CONSTRUCTION METHODS AND ARRANGEMENTS WILL BE CONSIDERED VALID OR
BINDING, AND ARE THEREFORE, DISALLOWED.
Q. GENERAL CONTRACTOR SHALL COMPLY WITH ALL DIRECTIVES OF THE OWNER. IF CONFLICTS
BETWEEN DRAWINGS, SPECIFICATIONS AND REQUIREMENTS OF BUILDING OWNER AND/OR
OPERATORS ARISE, THEY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.
R. THE HVAC, PLUMBING AND ELECTRICAL CONTRACTORS SHALL COORDINATE THEIR WORK WITH THE
WORK OF OTHER TRADES TO ASSURE THAT THE WORK CAN BE INSTALLED IN A WORKMAN-LIKE
MANNER. EACH CONTRACTOR SHALL BE EXPECTED TO COOPERATE WITH OTHER CONTRACTORS IN
THE PLACEMENT OF WORK TO AVOID CONFLICTS AND MAINTAIN JOB PROGRESS.
S. IT IS THE INTENT OF THESE DRAWINGS THAT A COMPLETE JOB IS TO BE ACCOMPLISHED IN PREPARING THE BID. THE BIDDER SHALL MAKE ALLOWANCES FOR DETAILS WHICH MIGHT HAVE BEEN
INADVERTENTLY OMITTED FROM THE DRAWINGS.
T. ALL EXISTING DUCTWORK, ELECTRICAL OR PIPING IS NOT NECESSARILY SHOWN ON THE DRAWINGS.
U. BEFORE CONTRACTOR(S) BID THE JOB, IT IS IMPERATIVE THEY VISIT THE JOBSITE AND FIELD VERIFY
THE EXACT LOCATION OF ALL EXISTING EQUIPMENT, DUCTWORK, ETC. IT WILL BE PART OF THE CONTRACTOR'S RESPONSIBILITY TO DESIGN AND RELOCATE ANY EXISTING OBSTACLES WHICH WILL INTERFERE WITH THE CONTRACTOR'S ABILITY TO INSTALL ALL NEW OR RELOCATED WORK ON HIS
CONTRACT.
A. ALL EXISTING DUCTWORK, ELECTRICAL OR PIPING IS NOT NECESSARILY SHOWN ON THE DRAWINGS.
B. BEFORE CONTRACTOR(S) BID THE JOB, IT IS IMPERATIVE THEY VISIT THE JOBSITE AND FIELD VERIFY
THE EXACT LOCATION OF ALL EXISTING EQUIPMENT, DUCTWORK, ETC. IT WILL BE PART OF THE CONTRACTOR'S RESPONSIBILITY AND COST TO ENGINEER AND RELOCATE ANY EXISTING OBSTACLES WHICH WILL INTERFERE WITH THE CONTRACTOR'S ABILITY TO INSTALL ALL NEW OR RELOCATED
WORK ON HIS CONTRACT.
C. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD AND NOTIFY PROJECT ENGINEER OF ALL
DISCREPANCIES IF ANY, FOUND PRIOR TO PLACEMENT OF ANY COMPONENTS
D. THE CONTRACTOR WILL TAKE ALL NECESSARY PRECAUTIONS INCLUDING THE BUILDING AND
MAINTENANCE OF DUST TIGHT PARTITIONS, DAILY VACUUMING, SWEEPING, AND PROVISION OF CLEAN FLOOR MATS AT THE PROJECT ENTRANCES, TO PREVENT THE INFILTRATION OF DIRT AND
DUST FROM THE CONSTRUCTION AREAS INTO THE OWNER OCCUPIED AREAS.
E. PATCH ALL FINISHES WHERE DISTURBED BY THE WORK AND WHERE UNFINISHED SURFACES HAVE
BEEN EXPOSED BY DEMOLITION. PATCHING MUST MATCH ADJACENT MATERIALS, COLORS, AND
FINISHES. WALL SURFACES THAT ARE PATCHED SHALL HAVE THE FINISHES (PAINT, VINYL WALL
COVERING, ETC.) REPLACED FROM CORNER TO CORNER AND FLOOR TO CEILING.
F. UNLESS OTHERWISE INDICATED FINISH ALL NEW FRAMES AND PARTITIONS TO MATCH SURROUNDING.
NEW HOLLOW METAL DOORS SHALL BE PAINTED SAME COLOR AS FRAMES. EXISTING PARTITIONS
RECEIVING NEW DOOR FRAMES THAT HAVE VINYL WALL COVERING (VWC) SHALL HAVE THE VWC
COMPLETELY REMOVED AND REPLACED WITH NEW VWC OF MATCHING TEXTURE AND COLOR
G. PAINT ALL EXPOSED NEW AND EXISTING PIPING, CONDUIT, WIRE MOLD, ELECTRICAL PANELS, ACCESS
PANELS, ETC.,TO MATCH WALL FINISH UNLESS OTHERWISE NOTED.
H. CORRIDOR WALLS AND PLUMBING PARTITIONS SHALL BE CONSIDERED 1 HOUR FIRE RATED WALLS, UON, AND NEW OR EXISTING PENETRATIONS MUST BE SEALED ACCORDINGLY WITH APPROVED
FIRESTOPPING MATERIAL THE SAME DAY THE PENETRATION IS MADE OR DISCOVERED. ALL FLOOR SLABS, VERTICAL SHAFTS AND STAIRWELLS SHALL BE CONSIDERED 2 HOUR RATED PARTITIONS AND BE SEALED ACCORDINGLY IN THE MANNER LISTED HEREIN. PENETRATIONS THROUGH THE EXTERIOR
WALLS SHALL BE SEALED WATERTIGHT.
I. ALL NEW VERTICAL AND HORIZONTAL DUCTS, PIPES, CONDUITS, ETC.,IN FINISHED ROOMS OR AREAS
THROUGHOUT BUILDING, NOT ENCASED IN MASONRY OR CONCRETE CONSTRUCTION, SHALL BE
FURRED IN, THE FURRING FINISHED TO MATCH THE ROOM FINISH.
J. WHENEVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE REMOVED, SUCH
REMOVAL SHALL INCLUDE ALL ANCHORS, HANGERS, FOUNDATIONS, ETC., UNLESS NOTED
OTHERWISE. AFTER REMOVAL; FLOORS, WALLS, AND CEILINGS SHALL BE FINISHED TO MATCH
ADJOINING SURFACES.
K. UTILITY WORK THAT WILL REQUIRE A SHUTDOWN OF EXISTING SERVICE(S) WILL BE DONE AFTER NORMAL WORKING HOURS (NIGHTS, WEEKENDS, HOLIDAYS, ETC.) AT NO ADDITIONAL COST TO THE
GOVERNMENT. WORK MUST BE SCHEDULED WITH THE COR.
L. WORK THAT MUST OCCUR IN OCCUPIED AREAS, SUCH AS PUBLIC CORRIDORS, OF THE MEDICAL CENTER OR DISRUPT A MEDICAL CENTER FUNCTION WILL BE DONE AT TIMES OTHER THAN NORMAL
WORKING HOURS (NIGHTS, WEEKENDS, HOLIDAYS, ETC.) AT NO ADDITIONAL COST TO THE
GOVERNMENT. WORK MUST BE SCHEDULED WITH THE V.A. PROJECT ENGINEER.
M. ALL ELECTRICAL CIRCUITRY TO BE CONCEALED UNLESS OTHERWISE SPECIFIED. CIRCUITING FOR
ELECTRIC DOOR HOLD OPENS IN MASONRY WALLS SHALL BE SURFACE RACEWAY.
N. COORDINATE ALL WORK WITH OTHER TRADES AND EXISTING CONDITIONS TO ELIMINATE CONFLICTS AND/OR INTERFERENCES. THE CONTRACTOR SHALL PROVIDE ALL OFFSETS, FITTINGS, TRANSITIONS, EXTENSIONS, ETC., REQUIRED FOR A COMPLETE AND FUNCTIONAL SYSTEM.
O. DRAWINGS ARE DIAGRAMMATIC AND SHOW ONLY THE GENERAL ARRANGEMENT OF EACH SYSTEM.
BECAUSE OF SMALL SCALE OF DRAWINGS IT IS NOT POSSIBLE TO SHOW OR INDICATE ALL BRANCHES, OFFSETS, FITTINGS, BOXES, AND ACCESSORIES WHICH MAY BE REQUIRED. CONTRACTOR MUST
CAREFULLY INVESTIGATE STRUCTURAL AND FINISH CONDITIONS AFFECTING ALL WORK, FURNISHING
SUCH FITTINGS, TRAPS, VALVES, BOXES, ACCESSORIES, ETC., AS MAY BE REQUIRED.
P. LOCATIONS OF NEW EQUIPMENT, PIPING, AND ASSOCIATED ITEMS SHOWN ON THE DRAWINGS ARE SCHEMATIC ONLY. THE CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION AND ELEVATION FOR ALL WORK, INCLUDING CONNECTIONS TO EXISTING WORK. ALL OFFSETS, FITTINGS, TRANSITIONS, EXTENSIONS, ETC., REQUIRED FOR A COMPLETE AND FUNCTIONAL SYSTEM SHALL BE PROVIDED AT
NO ADDITIONAL COST.
Q. ALL EXISTING DUCTWORK, ELECTRICAL OR MECHANICAL PIPING, CABLE TRAYS, ETC., IS NOT NECESSARILY SHOWN ON THE DRAWINGS. BEFORE CONTRACTOR PLACES A BID IT IS IMPERATIVE THEY VISIT THE JOBSITE AND FIELD VERIFY THE EXACT LOCATION OF ALL EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. IT WILL BE PART OF THE CONTRACTOR'S RESPONSIBILITY AND THE CONTRACTOR WILL BEAR THE COST TO ENGINEER AND RELOCATE ANY EXISTING OBSTACLES WHICH WILL INTERFERE WITH THE CONTRACTOR'S ABILITY TO INSTALL ALL NEW OR RELOCATED WORK IN
THIS PROJECT.
R. CONTRACTOR SHALL NOT INSTALL CONDUIT, PIPING, LIGHTING, OR OTHER OBSTRUCTIONS UNDER OR ADJACENT TO HVAC EQUIPMENT THAT WILL ELIMINATE OR OBSTRUCT ACCESS TO COILS, MOTORS, VALVES, SWITCHES, PANELS, ETC.
S. BEFORE THE CONTRACTOR BEGINS WORK HE SHALL RECORD ANY EXISTING SYSTEM INFORMATION
SUCH AS TEMPERATURE, FLOW RATE, PRESSURE, CURRENT, VOLATAGE, OR ANY OTHER
INFORMATION NECESSARY FOR HIM TO RETURN THE AFFECTED SYSTEM TO ORIGINAL OPERATING CONDITION. UNLESS NOTED OTHERWISE IT IS ASSUMED THAT ALL SYSTEMS ( HVAC, ELECTRICAL, PLUMBING, ETC.) ARE WORKING PROPERLY IN EVERY MANNER AT THE BEGINNING OF THE PROJECT.
THE CONTRACTOR'S RECORDED MEASUREMENTS MUST BE SUBMITTED TO THE PROJECT ENGINEER
FOR REVIEW AND ACCEPTANCE BEFORE ANY DEMOLITION OR OTHER RELATED WORK CAN PROCEED.
T. FOR DOORS BEING REPLACED: IF THE EXISTING DOOR HAS SIGNAGE APPLIED TO IT, THIS SIGNAGE SHOULD BE CAREFULLY REMOVED AND REAPPLIED TO THE NEW DOOR. IF THE SIGNAGE IS DAMAGED
DURING REMOVAL OR CANNOT OTHERWISE BE REAPPLIED IT SHOULD BE REPLACED WITH NEW
SIGNAGE OF IDENTICAL TYPE.
U. THE CONTRACTOR WILL BE RESPONSIBLE FOR MAINTAINING ALL EXISTING ACCESS DOORS TO
CONSTRUCTION AREAS, EXISTING MECHANICAL AND ELECTRICAL AREAS, ASSIGNED STORAGE
AREAS, EQUIPMENT ACCESS AREAS, ETC. DOORS MUST BE RESTORED TO THE CONDITION
ENCOUNTERED AT BEGINNING OF PROJECT. THIS INCLUDES DOOR REPLACEMENT, HARDWARE
REPLACEMENT, HARDWARE REPAIR, DOOR REPAIR, ETC.
V. IT IS IMPORTANT THAT ALL REPLACEMENT DOORS HAVE A GAP OF LESS THAN 3/4" BETWEEN THE
BOTTOM OF THE DOOR AND THE FLOOR AT ALL POINTS. CONTRACTOR MUST COORDINATE
INSTALLED DOOR FRAME HEIGHT OR MAKE OTHER NECESSARY MODIFICATIONS0 TO MEET THIS
REQUIREMENT AND KEEP FIRE RATING OF DOOR AND FRAME. BOTTOM SWEEPS ARE NOT
ACCEPTABLE UNLESS SPECIFICALLY STATED ON DRAWING.
W. IF THERE IS ANY WORK TO BE DONE ON EXISTING ROOFS, SUCH AS ROOF PENETRATIONS OR STANDS, OR ANYTHING THAT DAMAGES THE INTEGRITY OF THE ROOF, THIS WORK MUST BE DONE BY A CONTRACTOR LICENSED BY THE ROOFING MEMBRANE MANUFACTURER. HE MUST BE APPROVED BY
THE MEMBRANE MANUFACTURER SO AS TO NOT VOID OR INTERRUPT EXISTING SINGLE PLY
MEMBRANE ROOF WARRANTIES.
X. EXISTING CIRCUITRY (CONDUIT, BOXES, WIRE, ETC.) MAY BE REUSED AT THE CONTRACTOR'S OPTION AS LONG AS IT MEETS THE SAME SPECIFICATIONS REQUIRED FOR NEW CIRCUITRY. ALL WORK, NEW
AND EXISTING, SHALL COMPLY WITH THE LATEST NEC CODE.
Y. WHERE DOOR AND HARDWARE ARE SHOWN TO BE REMOVED, THE DOOR STOPS ARE TO REMAIN AND
BE REUSED UNLESS NOTED OTHERWISE.
CONTRACTOR GENERAL NOTESPROJECT GENERAL NOTESBUILDING CODES, GUIDE AND MANUALS
• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE
INSTITUTE AND COMMENTARY (ACI 318)
• MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN
SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, AMERICAN INSTITUTE OF STEEL
CONSTRUCTION (AISC)
• DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL,
COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND NEW LOW-
RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434, AND 435.
• FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS:
MEMORANDUM OF UNDERSTANDING (MOU)
• EXECUTIVE ORDER 13834
• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL
REQUIRMENTS SECTION 01010 IF THE VA MASTER CONSTRUCTION SPECIFICATION.
• VENTILATION FOR THE ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1 –
2004.
• SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15 – 2007.
• ENERGY POLICY ACT OF 2005 (EPACT)
PLUMBING WATER LAVATORIES SHOWER DRINKING SERVICE
FIXTURES FOUNTAINS SINKS
BUSINESS 1 PER 25 1 PER 40 1 PER 100 1 SINK
(FIRST 50) (FIRST 80)
REQUIRED 2 WC 2 LAVS 1 DF 1 SINK
RESIDENTIAL 1 PER UNIT 1 PER UNIT 1 PER UNIT 1 SINK
REQUIRED 14 WC 14 LAVS 14 SHWR 2 SINKS
TOTAL REQUIRED 16 WC 16 LAVS 14 SHWR 1 DF 3 SINKS
TOTAL PROVIDED 18 WC 18 LAVS 14 SHWR 2 DF 3 SINKS
ARRANGEMENT OF MEANS OF EGRESS
BUISNESS OCCUPANCY - FULLY SPRINKLERED
TRAVEL DISTANCE (NFPA 101 39.2.6.3) 300 FT
COMMON PATH OF TRAVEL (NFPA 101 39.2.5.3.1) 100 FT
DEAD END (NFPA 101 39.2.5.2) 50 FT
LARGE RESIDENTIAL BOARD AND CARE - FULLY SPRINKLERED
TRAVEL DISTANCE
WITHIN ROOM TO CORRIDOR (NFPA 101 33.3.2.6.2) 125 FT
CORRIDOR DOOR TO EXIT (NFPA 101 33.3.2.6.3.1) 100 FT
COMMON PATH OF TRAVEL (NFPA 101 33.3.2.5.3) 160 FT
DEAD END (NFPA 101 33.3.2.5.4) 50 FT
MISCELLANEOUS
YES NO
FIRE RESISTIVE CORRIDORS
SMOKE TIGHT CORRIDORS (SMOKE PARTITIONS)
INCIDENTAL USE AREA RATINGS SEE PLANS
INTERIOR FINISHES CLASSIFICATION EXITS A
EXIT ACCESS CORRDORS A
OTHER SPACES B
FIRE-RESISTANCE REQUIREMENTS: CONSTRUCTION TYPE V (111)
STRUCTURAL FRAME:
COLUMNS: EXISTING / 1HR NFPA - A.8.2.1.2
GIRDERS: EXISTING / 1HR NFPA - A.8.2.1.2
TRUSSES: EXISTING / 1HR NFPA - A.8.2.1.2
BEARING WALLS:
EXTERIOR BEARING WALLS: EXISTING / 1 HR NFPA - A.8.2.1.2
BEARING WALLS INTERIOR: EXISTING / 1 HR NFPA - A.8.2.1.2
NON-BEARING WALLS:
EXTERIOR NON-BEARING WALLS: 0 HR NFPA - A.8.2.1.2
INTERIOR NON-BEARING WALLS: SEE LIFE PLANS
FLOOR CONSTRUCTION:
FLOOR AND FLOOR/CEILING: EXISTING / 1HR NFPA - A.8.2.1.2
PRIME & SEC. BEAMS & JOISTS: EXISTING / 0HR NFPA - A.8.2.1.2
ROOF CONSTRUCTION:
ROOF AND ROOF/CEILING: EXISTING / 1HR NFPA - A.8.2.1.2
PRIME & SEC. BEAMS & JOISTS: EXISTING / 0HR NFPA - A.8.2.1.2
OTHER:
SHAFTS & EXIT PASSAGEWAYS: 1HR NFPA - 33.2.3.1.3, 8.6.5
ELEVATOR (ACCESSIBLE EGRESS) 2HR NFPA - 9.4/ASME 17.1
VA FORM 08 - 6231
A
B
C
D
A
B
C
D
2 4 5 61
6"
6"
6"
6"
O N
E E
IG
H
T H
I N
C H
O
N E
F O
O T
1/
8"
'-0
O
N E
Q U
A R
T E
R I
N C
H
O N
E F
O O
T
1/ 4"
'-0
T H
R E
E E
IG
H
T H
S
IN
C H
O
N E
F O
O T
(3 /8
1' -0
O
N E
H A
LF
I
N C
H
O N
E F
O O
T
1/ 2"
'-0
T H
R E
E Q
U A
R T
E R
S
IN
C H
O
N E
F O
O T
3/
4"
'-0
O
N E
I N
C H
O
N E
F O
O T
1"
'-0
O N
E A
N D
O N
E H
A
LF
I N
C H
E S
O
N E
F O
O T
1/ 2"
'-0
T H
R E
E
IN
C H
E S
O
N E
F O
O T
3"
'-0
32 4 5 61
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANTS
STRUCTURAL:
ALBERTSON ENGINEERING, INC.
3202 W. MAIN ST., #C
RAPID CITY, SD 57702
605-343-9606
MEP:
WEST PLAINS ENGINEERING, INC.
1750 RAND ROAD
RAPID CITY, SD 57702
605-348-7455
STEPHEN KILBER MIKE SIGMAN (ELEC)
MICHAEL HEINRICH (MECH)
C :\U se rs
\K .K ue pe r\D oc um en ts \2
D om R en ov
B ui ld in g
_k yl ek 9D
U H
U .rv t 6/
2/
:0 1:
P
M
GI014
CODE REVIEW, PCRA, ICRA, ISLM, GEN NOTES
STONE GROUP ARCHITECTS
600 EAST 7TH ST.
SIOUX FALLS, SD 57103
605-271-1144
TODD STONE
DOM RENOVATION FOR
SEMIPRIVATE ROOMS
HOT SPRINGS, SD
DOUG SPRINKLE
06/03/2025 JM/GB/TM TL/KK
SGA #211921
VA #568A4-21-208
BID DOCUMENTS
ISSUE # DESCRIPTION DATE
1 BID DOCUMENTS 06/03/2025
UP
UP
204 SF
B14
STAFF
LOUNGE
107 SF
B13
MH OFFICE
100 SF
B12
MH OFFICE
100 SF
B11
MH OFFICE
412 SF
B10
MECHANICAL
58 SF
B09
HAC
100 SF
B08
MH OFFICE
62 SF
B15A
STORAGE
76 SF
B16
TOILET,
WOMEN
122 SF
B17
MH OFFICE
128 SF
B18
MH OFFICE
128 SF
B19
MH OFFICE 75 SF
B20
TOILET,
MEN
109 SF
B21
MH OFFICE
331 SF
B05
GYM
204 SF
B07
GROUP
ROOM MH
67 SF
B01
STORAGE
14 SF
B03
ELEC
100 SF
ELEVATOR
65 SF
B05A
ELEVATOR
EQUIPMENT
164 SF
B06
UNASSIGNED
MH
203 SF
B15
GROUP
ROOM MH
1002 SF
B00
BASEMENT
CORRIDOR
LENGTH OF TRAVEL: 69'-7"
LENGTH OF TRAVEL: 97'-1"
FEC
FEC
8.6"
34.0"
1 14
EX
157 SF
B04
UNASSIGNED
MH
125 SF
B02
TR
1 1 1
1 1
75'-0"
75'-0"
TWO-STORY EXIT ENLCLOSURE IS
OPEN TO BASEMENT WITHIN AN
EXISTING BUILDING. COMPLIANT
WITH NFPA 101 PER 7.2.2.5.1.3
B06A
FIRE
SERVICE
B00
BASEMENT
CORRIDOR
8.7"
60.0"
TO B.O. STAIR + 21'-0" (B.O. STAIR TO DOOR ABOVE)
21.9"
38.0"
8.33A
14.01
G A
T E
22.03
0.0"
0.0"
OCCUPANTS
REQUIRED WIDTH
PROVIDED WIDTH
OCCUPANT LOAD
CODE & EGRESS SYMBOL LEGEND
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
DIRECTION OF EGRESS
DIRECTION OF EGRESSPATH OF TRAVEL
START OF PATH TRAVEL DISTANCE (TD)
TD = X'-X"
FEC
FE
EXITEX
CONSTRUCTION LEGEND
AREA NOT IN CONSTRUCTION BOUNDARIES
EXISTING COMPONENTS
NEW COMPONENTS
GENERAL CODE NOTES
H. SMOKE SEALS TO BE INSTALLED AT ALL RATED DOORS.
I. SMOKE SEALS TO BE INSTALLED AT NON RATED SMOKE PARTITION & BARRIER DOORS UON.
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER BEFORE
PROCEEDING WITH THE WORK.
B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE
DRAWINGS.
C. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.
D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
E. DETAILS SHOWN ARE TYPICAL UON. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.
F. SEE STRUCTURAL, MECHANICAL, ELECTRICAL, & PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
G. DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF EQUIPMENT, CENTERLINE OF FIXTURE, OR
GRID UON. DIMENSIONS ARE TO FACE OF FINISH ON INTERIOR ELEVATIONS AND/OR WHERE THE
ABBREVIATION "CLR" IS USED UON.
BUILDING & LIFE SAFETY REQUIREMENT LEGEND
DESCRIPTION
WALL
RATING
PARTITION KEY
NFPA 101-2021
IBC 2023
OPENINGS
RATING REFERENCE
FIRE WALL:
BUILDING SEPARATION
90 MINFIRE BARRIER:
OCCUPANCY/AREA SEPARATION
90 MIN
FIRE BARRIER:
HORIZONTAL EXIT & REFUGE AREA
90 MINNFPA 7.1.3.2
NFPA 8.2.1.3
IBC 716.1
NFPA 8.3.3.2.2
IBC 716.1
NFPA 8.3.3.2.2
2 HOUR
FIRE BARRIER
VERTICAL EXIT PASSAGEWAY
60 MIN
FIRE BARRIER
HORIZONTAL EXIT PASSAGEWAY
NFPA 7.2.6
NFPA 8.6
NFPA 8.3.3.2.2
NFPA 8.3.3.2.2
FIRE BARRIER
VERTICAL EXIT ENCLOSURE/SHAFT
(2 HR = 4 OR MORE STORIES)
(1 HR = LESS THAN 4 STORIES) 60 MIN
90 MINNFPA 8.6
IBC 716.1
NFPA 8.3.3.2.2
IBC 716.1
90 MIN
1 HR
2 HR
SMOKE PARTITION
(SPRINKLERED)
HAZARDOUS/INCIDENTAL USE
NR
SMOKE BARRIER
SUBDIVIDING SPACES
20 MIN
SMOKE PARTITION
SLEEPING RM SEPARATION REQ
EXIT ACCESS CORRIDOR
(SPRINKLERED) CORRIDOR WALLS
NR
NFPA 8.5
IBC 716.1
NFPA 8.4.2
NFPA 32.3.3.6
NFPA 8.4.2
IBC 407.3
NFPA 8.4.2
NFPA 8.7.1.2
NFPA 8.3.3.2.2, 19.3.7.8
IBC 716.1
NFPA 8.7.1.2
NFPA 8.3.3.2.2, 8.4
NFPA 32.3.3.6
NFPA 8.4.3
1 HOUR
NR
NR
0.5 HOUR
NR
FIRE BARRIER
45 MINNFPA 8.7.1.1
IBC 716.1
NFPA 8.3.3.2.2, 8.7.1.1
IBC 716.1
1 HOUR
1 HR
2 HR
1 HR
2 HR
60 MIN
90 MIN
NFPA 8.2.1.3
IBC 716.1
NFPA 8.3.3.2.2
IBC 716.1
DAMPERS
TYPE REFERENCE
FIRE
90 MIN
FIRE
90 MIN
FIRE
90 MIN
NFPA 8.3.4.3, 9.2.1
NFPA 8.3.4.3, 9.2.1
N/A
N/A N/A
SMOKE
90 MIN
NFPA 8.5.5.3
VARIES NFPA 8.4.4
VARIES NFPA 8.4.4, 8.4.6.2
VARIES NFPA 8.4.4, 8.4.6.2
NOT ALLOWED
UNLESS SERVING
STAIR ONLY
N/A
NOT ALLOWED N/A
N/A NFPA 8.6.4
VA FORM 08 - 6231
A
B
C
D
A
B
C
D
2 4 5 61
6"
6"
6"
6"
O N
E E
IG
H
T H
I N
C H
O
N E
F O
O T
1/
8"
'-0
O
N E
Q U
A R
T E
R I
N C
H
O N
E F
O O
T
1/ 4"
'-0
T H
R E
E E
IG
H
T H
S
IN
C H
O
N E
F O
O T
(3 /8
1' -0
O
N E
H A
LF
I
N C
H
O N
E F
O O
T
1/ 2"
'-0
T H
R E
E Q
U A
R T
E R
S
IN
C H
O
N E
F O
O T
3/
4"
'-0
O
N E
I N
C H
O
N E
F O
O T
1"
'-0
O N
E A
N D
O N
E H
A
LF
I N
C H
E S
O
N E
F O
O T
1/ 2"
'-0
T H
R E
E
IN
C H
E S
O
N E
F O
O T
3"
'-0
32 4 5 61
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANTS
STRUCTURAL:
ALBERTSON ENGINEERING, INC.
3202 W. MAIN ST., #C
RAPID CITY, SD 57702
605-343-9606
MEP:
WEST PLAINS ENGINEERING, INC.
1750 RAND ROAD
RAPID CITY, SD 57702
605-348-7455
STEPHEN KILBER MIKE SIGMAN (ELEC)
MICHAEL HEINRICH (MECH)
C :\U se rs
\K .K ue pe r\D oc um en ts \2
D om R en ov
B ui ld in g
_k yl ek 9D
U H
U .rv t 6/
2/
:0 1:
P
M
GI100
LIFE SAFETY PLAN - BASEMENT
STONE GROUP ARCHITECTS
600 EAST 7TH ST.
SIOUX FALLS, SD 57103
605-271-1144
TODD STONE
DOM RENOVATION FOR
SEMIPRIVATE ROOMS
HOT SPRINGS, SD
DOUG SPRINKLE
06/03/2025 JM/GB/TM TL/KK
SGA #211921
VA #568A4-21-208
BID DOCUMENTS
3/16" = 1'-0" D5
LIFE SAFETY PLAN - BASEMENT
TRUE
NORTH
PLAN
NORTH
ISSUE # DESCRIPTION DATE
1 BID DOCUMENTS 06/03/2025
KEYNOTES
KEY VALUE KEYNOTE TEXT
8.33A SMOKE GUARD CURTAIN. INSTALL FLUSH WITH CEILING.
14.01 ELEVATOR.
22.03 BI-LEVEL ADA DRINKING FOUNTAIN W/ BOTTLE FILLING STATION. REF PLUMB & SPECS.
D D
W W
DN
DN
DN UP
UP
0.0"
0.0"
OCCUPANTS
REQUIRED WIDTH
PROVIDED WIDTH
OCCUPANT LOAD
CODE & EGRESS SYMBOL LEGEND
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
DIRECTION OF EGRESS
DIRECTION OF EGRESSPATH OF TRAVEL
START OF PATH TRAVEL DISTANCE (TD)
TD = X'-X"
FEC
FE
EXITEX
CONSTRUCTION LEGEND
AREA NOT IN CONSTRUCTION BOUNDARIES
EXISTING COMPONENTS
NEW COMPONENTS
GENERAL CODE NOTES
H. SMOKE SEALS TO BE INSTALLED AT ALL RATED DOORS.
I. SMOKE SEALS TO BE INSTALLED AT NON RATED SMOKE PARTITION & BARRIER DOORS UON.
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER BEFORE
PROCEEDING WITH THE WORK.
B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE
DRAWINGS.
C. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.
D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
E. DETAILS SHOWN ARE TYPICAL UON. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.
F. SEE STRUCTURAL, MECHANICAL, ELECTRICAL, & PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
G. DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF EQUIPMENT, CENTERLINE OF FIXTURE, OR
GRID UON. DIMENSIONS ARE TO FACE OF FINISH ON INTERIOR ELEVATIONS AND/OR WHERE THE
ABBREVIATION "CLR" IS USED UON.
BUILDING & LIFE SAFETY REQUIREMENT LEGEND
DESCRIPTION
WALL
RATING
PARTITION KEY
NFPA 101-2021
IBC 2023
OPENINGS
RATING REFERENCE
FIRE WALL:
BUILDING SEPARATION
90 MINFIRE BARRIER:
OCCUPANCY/AREA SEPARATION
90 MIN
FIRE BARRIER:
HORIZONTAL EXIT & REFUGE AREA
90 MINNFPA 7.1.3.2
NFPA 8.2.1.3
IBC 716.1
NFPA 8.3.3.2.2
IBC 716.1
NFPA 8.3.3.2.2
2 HOUR
FIRE BARRIER
VERTICAL EXIT PASSAGEWAY
60 MIN
FIRE BARRIER
HORIZONTAL EXIT PASSAGEWAY
NFPA 7.2.6
NFPA 8.6
NFPA 8.3.3.2.2
NFPA 8.3.3.2.2
FIRE BARRIER
VERTICAL EXIT ENCLOSURE/SHAFT
(2 HR = 4 OR MORE STORIES)
(1 HR = LESS THAN 4 STORIES) 60 MIN
90 MINNFPA 8.6
IBC 716.1
NFPA 8.3.3.2.2
IBC 716.1
90 MIN
1 HR
2 HR
SMOKE PARTITION
(SPRINKLERED)
HAZARDOUS/INCIDENTAL USE
NR
SMOKE BARRIER
SUBDIVIDING SPACES
20 MIN
SMOKE PARTITION
SLEEPING RM SEPARATION REQ
EXIT ACCESS CORRIDOR
(SPRINKLERED) CORRIDOR WALLS
NR
NFPA 8.5
IBC 716.1
NFPA 8.4.2
NFPA 32.3.3.6
NFPA 8.4.2
IBC 407.3
NFPA 8.4.2
NFPA 8.7.1.2
NFPA 8.3.3.2.2, 19.3.7.8
IBC 716.1
NFPA 8.7.1.2
NFPA 8.3.3.2.2, 8.4
NFPA 32.3.3.6
NFPA 8.4.3
1 HOUR
NR
NR
0.5 HOUR
NR
FIRE BARRIER
45 MINNFPA 8.7.1.1
IBC 716.1
NFPA 8.3.3.2.2, 8.7.1.1
IBC 716.1
1 HOUR
1 HR
2 HR
1 HR
2 HR
60 MIN
90 MIN
NFPA 8.2.1.3
IBC 716.1
NFPA 8.3.3.2.2
IBC 716.1
DAMPERS
TYPE REFERENCE
FIRE
90 MIN
FIRE
90 MIN
FIRE
90 MIN
NFPA 8.3.4.3, 9.2.1
NFPA 8.3.4.3, 9.2.1
N/A
N/A N/A
SMOKE
90 MIN
NFPA 8.5.5.3
VARIES NFPA 8.4.4
VARIES NFPA 8.4.4, 8.4.6.2
VARIES NFPA 8.4.4, 8.4.6.2
NOT ALLOWED
UNLESS SERVING
STAIR ONLY
N/A
NOT ALLOWED N/A
N/A NFPA 8.6.4
160 SF
LOUNGE
213 SF
BEDROOM
TWO-BED
219 SF
BEDROOM
TWO-BED
215 SF
BEDROOM
TWO-BED
218 SF
BEDROOM
TWO-BED
222 SF
BEDROOM
TWO-BED
206 SF
BARIATRIC
BEDROOM
TWO-BED
124 SF
BEDROOM
ONE-BED
86 SF
116A
TOILET
82 SF
115A
TOILET42 SF
SOILED
UTILITY
1017 SF
FIRST
FLOOR
CORRIDOR
74 SF
114A
TOILET
74 SF
113A
TOILET
81 SF
112A
TOILET
102 SF
111A
BARIATRIC
TOILET
31 SF
HAC
43 SF
TOILET
70 SF
110A
TOILET
112 SF
LAUNDRY
100 SF
ELEVATOR
38 SF
105A
LINEN
87 SF
TR
17 SF
ELEC
226 SF
MULTIPURPOSE
KITCHENETTE
35 SF
STORAGE
28 SF
STORAGE
LENGTH OF TRAVEL: 82'-8"
LENGTH OF TRAVEL: 50'-1"
5.2"
44.0"
7.2"
34.0"
3 3 3 3
4.4"
40.0"
EX
EX
FEC
15 20
1 1
EX
5.8"
34.0"
EX
EX
5.2"
44.0"
75'-0"
75'-0"
FEC
TWO-STORY EXIT ENLCLOSURE IS
OPEN TO BASEMENT WITHIN AN
EXISTING BUILDING. COMPLIANT
WITH NFPA 101 PER 7.2.2.5.1.3
100A
STORAGE
107A
COMPUTER
6.6"
54.0"
STAIRWELL
21.9"
38.0"
73 37
14.01
8.33A 8.33C
22.03
G A
T E
3/16" = 1'-0" D5
LIFE SAFETY PLAN - FIRST FLOOR
VA FORM 08 - 6231
A
B
C
D
A
B
C
D
2 4 5 61
6"
6"
6"
6"
O N
E E
IG
H
T H
I N
C H
O
N E
F O
O T
1/
8"
'-0
O
N E
Q U
A R
T E
R I
N C
H
O N
E F
O O
T
1/ 4"
'-0
T H
R E
E E
IG
H
T H
S
IN
C H
O
N E
F O
O T
(3 /8
1' -0
O
N E
H A
LF
I
N C
H
O N
E F
O O
T
1/ 2"
'-0
T H
R E
E Q
U A
R T
E R
S
IN
C H
O
N E
F O
O T
3/
4"
'-0
O
N E
I N
C H
O
N E
F O
O T
1"
'-0
O N
E A
N D
O N
E H
A
LF
I N
C H
E S
O
N E
F O
O T
1/ 2"
'-0
T H
R E
E
IN
C H
E S
O
N E
F O
O T
3"
'-0
32 4 5 61
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANTS
STRUCTURAL:
ALBERTSON ENGINEERING, INC.
3202 W. MAIN ST., #C
RAPID CITY, SD 57702
605-343-9606
MEP:
WEST PLAINS ENGINEERING, INC.
1750 RAND ROAD
RAPID CITY, SD 57702
605-348-7455
STEPHEN KILBER MIKE SIGMAN (ELEC)
MICHAEL HEINRICH (MECH)
C :\U se rs
\K .K ue pe r\D oc um en ts \2
D om R en ov
B ui ld in g
_k yl ek 9D
U H
U .rv t 6/
2/
:0 1:
P
M
GI101
LIFE SAFETY PLAN - 1ST FLOOR
STONE GROUP ARCHITECTS
600 EAST 7TH ST.
SIOUX FALLS, SD 57103
605-271-1144
TODD STONE
DOM RENOVATION FOR
SEMIPRIVATE ROOMS
HOT SPRINGS, SD
DOUG SPRINKLE
06/03/2025 JM/GB/TM TL/KK
SGA #211921
VA #568A4-21-208
BID DOCUMENTS
TRUE
NORTH
PLAN
NORTH
ISSUE # DESCRIPTION DATE
1 BID DOCUMENTS 06/03/2025
KEYNOTES
KEY VALUE KEYNOTE TEXT
8.33A SMOKE GUARD CURTAIN. INSTALL FLUSH WITH CEILING.
8.33C EXPOSED SMOKE GUARD CURTAIN.
W W
D D
DN
DN
DN
0.0"
0.0"
OCCUPANTS
REQUIRED WIDTH
PROVIDED WIDTH
OCCUPANT LOAD
CODE & EGRESS SYMBOL LEGEND
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
DIRECTION OF EGRESS
DIRECTION OF EGRESSPATH OF TRAVEL
START OF PATH TRAVEL DISTANCE (TD)
TD = X'-X"
FEC
FE
EXITEX
CONSTRUCTION LEGEND
AREA NOT IN CONSTRUCTION BOUNDARIES
EXISTING COMPONENTS
NEW COMPONENTS
GENERAL CODE NOTES
H. SMOKE SEALS TO BE INSTALLED AT ALL RATED DOORS.
I. SMOKE SEALS TO BE INSTALLED AT NON RATED SMOKE PARTITION & BARRIER DOORS UON.
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER BEFORE
PROCEEDING WITH THE WORK.
B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE
DRAWINGS.
C. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.
D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
E. DETAILS SHOWN ARE TYPICAL UON. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.
F. SEE STRUCTURAL, MECHANICAL, ELECTRICAL, & PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
G. DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF EQUIPMENT, CENTERLINE OF FIXTURE, OR
GRID UON. DIMENSIONS ARE TO FACE OF FINISH ON INTERIOR ELEVATIONS AND/OR WHERE THE
ABBREVIATION "CLR" IS USED UON.
BUILDING & LIFE SAFETY REQUIREMENT LEGEND
DESCRIPTION
WALL
RATING
PARTITION KEY
NFPA 101-2021
IBC 2023
OPENINGS
RATING REFERENCE
FIRE WALL:
BUILDING SEPARATION
90 MINFIRE BARRIER:
OCCUPANCY/AREA SEPARATION
90 MIN
FIRE BARRIER:
HORIZONTAL EXIT & REFUGE AREA
90 MINNFPA 7.1.3.2
NFPA 8.2.1.3
IBC 716.1
NFPA 8.3.3.2.2
IBC 716.1
NFPA 8.3.3.2.2
2 HOUR
FIRE BARRIER
VERTICAL EXIT PASSAGEWAY
60 MIN
FIRE BARRIER
HORIZONTAL EXIT PASSAGEWAY
NFPA 7.2.6
NFPA 8.6
NFPA 8.3.3.2.2
NFPA 8.3.3.2.2
FIRE BARRIER
VERTICAL EXIT ENCLOSURE/SHAFT
(2 HR = 4 OR MORE STORIES)
(1 HR = LESS THAN 4 STORIES) 60 MIN
90 MINNFPA 8.6
IBC 716.1
NFPA 8.3.3.2.2
IBC 716.1
90 MIN
1 HR
2 HR
SMOKE PARTITION
(SPRINKLERED)
HAZARDOUS/INCIDENTAL USE
NR
SMOKE BARRIER
SUBDIVIDING SPACES
20 MIN
SMOKE PARTITION
SLEEPING RM SEPARATION REQ
EXIT ACCESS CORRIDOR
(SPRINKLERED) CORRIDOR WALLS
NR
NFPA 8.5
IBC 716.1
NFPA 8.4.2
NFPA 32.3.3.6
NFPA 8.4.2
IBC 407.3
NFPA 8.4.2
NFPA 8.7.1.2
NFPA 8.3.3.2.2, 19.3.7.8
IBC 716.1
NFPA 8.7.1.2
NFPA 8.3.3.2.2, 8.4
NFPA 32.3.3.6
NFPA 8.4.3
1 HOUR
NR
NR
0.5 HOUR
NR
FIRE BARRIER
45 MINNFPA 8.7.1.1
IBC 716.1
NFPA 8.3.3.2.2, 8.7.1.1
IBC 716.1
1 HOUR
1 HR
2 HR
1 HR
2 HR
60 MIN
90 MIN
NFPA 8.2.1.3
IBC 716.1
NFPA 8.3.3.2.2
IBC 716.1
DAMPERS
TYPE REFERENCE
FIRE
90 MIN
FIRE
90 MIN
FIRE
90 MIN
NFPA 8.3.4.3, 9.2.1
NFPA 8.3.4.3, 9.2.1
N/A
N/A N/A
SMOKE
90 MIN
NFPA 8.5.5.3
VARIES NFPA 8.4.4
VARIES NFPA 8.4.4, 8.4.6.2
VARIES NFPA 8.4.4, 8.4.6.2
NOT ALLOWED
UNLESS SERVING
STAIR ONLY
N/A
NOT ALLOWED N/A
N/A NFPA 8.6.4
160 SF
LOUNGE
213 SF
BEDROOM
TWO-BED
219 SF
BEDROOM
TWO-BED
215 SF
BEDROOM
TWO-BED
218 SF
BEDROOM
TWO-BED
222 SF
BEDROOM
TWO-BED
86 SF
216A
TOILET
82 SF
215A
TOILET
74 SF
214A
TOILET
74 SF
213A
TOILET
81 SF
212A
TOILET
102 SF
211A
BARIATRIC
TOILET
124 SF
BEDROOM
ONE-BED
206 SF
BARIATRIC
BEDROOM
TWO-BED
43 SF
TOILET
70 SF
210A
TOILET
112 SF
LAUNDRY
100 SF
ELEVATOR
38 SF
205A
LINEN
101 SF
TR17 SF
ELEC
1024 SF
SECOND
FLOOR
CORRIDOR
42 SF
SOILED
UTILITY
28 SF
STORAGE
37 SF
STORAGE
LENGTH OF TRAVEL: 81'-7"
LENGTH OF TRAVEL: 48'-8"
35 SF
ATTIC
ACCESS
3 3 3 3
15 21
1 1
2.4"
44.0"
7.4"
34.0"
4.6"
40.0"
EX
EX
EX
EX
2.4"
44.0"
FEC
FEC
75'-0"
75'-0"
200A
STORAGE
207A
COMPUTER
FSA
STATION
11.1"
38.0"
'-4
6.9"
54.0"
3' -6
5' -0
/2
1024 SF
SECOND
FLOOR
CORRIDOR
MULTIPURPOSE
KITCHENETTE
8.33C8.33A
14.01
5.42E
22.03
3/16" = 1'-0" D5
LIFE SAFETY PLAN - SECOND FLOOR
VA FORM 08 - 6231
A
B
C
D
A
B
C
D
2 4 5 61
6"
6"
6"
6"
O N
E E
IG
H
T H
I N
C H
O
N E
F O
O T
1/
8"
'-0
O
N E
Q U
A R
T E
R I
N C
H
O N
E F
O O
T
1/ 4"
'-0
T H
R E
E E
IG
H
T H
S
IN
C H
O
N E
F O
O T
(3 /8
1' -0
O
N E
H A
LF
I
N C
H
O N
E F
O O
T
1/ 2"
'-0
T H
R E
E Q
U A
R T
E R
S
IN
C H
O
N E
F O
O T
3/
4"
'-0
O
N E
I N
C H
O
N E
F O
O T
1"
'-0
O N
E A
N D
O N
E H
A
LF
I N
C H
E S
O
N E
F O
O T
1/ 2"
'-0
T H
R E
E
IN
C H
E S
O
N E
F O
O T
3"
'-0
32 4 5 61
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANTS
STRUCTURAL:
ALBERTSON ENGINEERING, INC.
3202 W. MAIN ST., #C
RAPID CITY, SD 57702
605-343-9606
MEP:
WEST PLAINS ENGINEERING, INC.
1750 RAND ROAD
RAPID CITY, SD 57702
605-348-7455
STEPHEN KILBER MIKE SIGMAN (ELEC)
MICHAEL HEINRICH (MECH)
C :\U se rs
\K .K ue pe r\D oc um en ts \2
D om R en ov
B ui ld in g
_k yl ek 9D
U H
U .rv t 6/
2/
:0 1:
P
M
GI102
LIFE SAFETY PLAN - 2ND FLOOR
STONE GROUP ARCHITECTS
600 EAST 7TH ST.
SIOUX FALLS, SD 57103
605-271-1144
TODD STONE
DOM RENOVATION FOR
SEMIPRIVATE ROOMS
HOT SPRINGS, SD
DOUG SPRINKLE
06/03/2025 JM/GB/TM TL/KK
SGA #211921
VA #568A4-21-208
BID DOCUMENTS
TRUE
NORTH
PLAN
NORTH
ISSUE # DESCRIPTION DATE
1 BID DOCUMENTS 06/03/2025
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.42E PAINTED STEEL STAIR W/ ALTERNATING TREADS.
8.33A SMOKE GUARD CURTAIN. INSTALL FLUSH WITH CEILING.
8.33C EXPOSED SMOKE GUARD CURTAIN.
GENERAL SITE NOTES
H. SEE MECHANICAL & ELECTRICAL PLANS FOR LOCATIONS OF HOSE BIBS & EXTERIOR OUTLETS.
I. PROTECT ALL EXISTING UTILITIES UON.
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER BEFORE
PROCEEDING WITH THE WORK.
B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE
DRAWINGS.
C. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.
D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
E. DETAILS SHOWN ARE TYPICAL UON. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.
F. SEE STRUCTURAL, MECHANICAL, ELECTRICAL, & PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
G. DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF EQUIPMENT, CENTERLINE OF FIXTURE, OR
GRID UON. DIMENSIONS ARE TO FACE OF FINISH ON INTERIOR ELEVATIONS AND/OR WHERE THE
ABBREVIATION "CLR" IS USED UON.
32.01
32.02
32.02
23.02
23.03
4' -0
4'-6"
32.03
32.03
32.03
32.05
32.05
32.03
32.05
32.03
SEE BASEMENT FLOOR PLAN FOR SIDEWALK CONTINUATION
V E
R
IF
Y W
/ C O
R
'-0
8'
-0
1.02
1.02
1.01
1.04
2.26
2.25
4'-0"
4'-6"
32.04
2.02
2.02A
2.02A
2.02A
SEE BASEMENT FLOOR PLAN FOR SIDEWALK CONTINUATION
GENERAL DEMOLITION NOTES
H. PROTECT ALL EXISTING UTILITIES UON.
I. WHERE APPLICABLE, ROOF PROTECTION IS TO BE PROVIDED FOR EXISTING ROOFS DURING ALL
PHASES OF CONSTRUCTION.
J. PATCH REMAINING EXISTING CONSTRUCTION AFFECTED BY DEMOLITION AS NEEDED.
K. PATCHING AND/OR INFILL TO MATCH EXISTING CONSTRUCTION & FINISHES UON.
L. EXISTING ITEMS TO REMAIN ARE SHOWN IN GRAY.
M. EXISTING ITEMS TO BE DEMOED ARE SHOWN WHITE WITH DASHED LINES.
N. INFILL OF FIRE PARTITION PENETRATIONS/OPENINGS SHALL MAINTAIN THE INTEGRITY OF THE
RATING.
O. CONTRACTOR TO COORDINATE RELOCATION AND/OR STORAGE OF SALVAGED ITEMS WITH THE
OWNER UON.
P. REFERENCE HAZARDOUS MATERIALS, MECHANICAL DEMOLITION, AND/OR PLUMBING DEMOLITION
SHEETS FOR INFORMATION REGARDING DEMOLITION OF HAZARDOUS MATERIALS.
Q. SEE STRUCTURAL DETAILS FOR INFORMATION REGARDING INFILL OF EXISTING STRUCTURAL FLOOR &
ROOF PENETRATIONS.
R. ALL CONSTRUCTION WASTE PRODUCED BY DEMOLITION TO BE PROPERTY OF CONTRACTOR UON.
S. PLUMBING ON BASEMENT LEVEL TO BE REMOVED TO BELOW THE FLOOR AND CAPPED. SEE
STRUCTURAL FOR CONCRETE PATCH DETAILS.
T. EXISTING INTERIOR PAINTED WOOD SURFACES TO BE STRIPPED TO BARE WOOD AND PREPPED FOR
NEW STAIN FINISH. EXISTING EXTERIOR PAINTED WOOD SURFACES TO BE STRIPPED TO BARE WOOD
AND PREPPED FOR NEW PAINT.
U. STRIP EXISTING STAINED WOOD WINDOWS, TRIM, AND SILLS. PREPARE FOR NEW STAIN FINISH.
EXISTING WOOD TRIM AND SILLS TO BE REMOVED AND SALVAGED AS NECESSARY FOR
REINSTALLATION
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER BEFORE
PROCEEDING WITH THE WORK.
B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE
DRAWINGS.
C. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.
D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
E. DETAILS SHOWN ARE TYPICAL UON. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.
F. SEE STRUCTURAL, MECHANICAL, ELECTRICAL, & PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
G. DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF EQUIPMENT, CENTERLINE OF FIXTURE, OR
GRID UON. DIMENSIONS ARE TO FACE OF FINISH ON INTERIOR ELEVATIONS AND/OR WHERE THE
ABBREVIATION "CLR" IS USED UON.
1" = 10'-0" D5
SITE PLAN
1" = 10'-0" B5
SITE PLAN - DEMOLITION
VA FORM 08 - 6231
A
B
C
D
A
B
C
D
2 4 5 61
6"
6"
6"
6"
O N
E E
IG
H
T H
I N
C H
O
N E
F O
O T
1/
8"
'-0
O
N E
Q U
A R
T E
R I
N C
H
O N
E F
O O
T
1/ 4"
'-0
T H
R E
E E
IG
H
T H
S
IN
C H
O
N E
F O
O T
(3 /8
1' -0
O
N E
H A
LF
I
N C
H
O N
E F
O O
T
1/ 2"
'-0
T H
R E
E Q
U A
R T
E R
S
IN
C H
O
N E
F O
O T
3/
4"
'-0
O
N E
I N
C H
O
N E
F O
O T
1"
'-0
O N
E A
N D
O N
E H
A
LF
I N
C H
E S
O
N E
F O
O T
1/ 2"
'-0
T H
R E
E
IN
C H
E S
O
N E
F O
O T
3"
'-0
32 4 5 61
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANTS
STRUCTURAL:
ALBERTSON ENGINEERING, INC.
3202 W. MAIN ST., #C
RAPID CITY, SD 57702
605-343-9606
MEP:
WEST PLAINS ENGINEERING, INC.
1750 RAND ROAD
RAPID CITY, SD 57702
605-348-7455
STEPHEN KILBER MIKE SIGMAN (ELEC)
MICHAEL HEINRICH (MECH)
C :\U se rs
\K .K ue pe r\D oc um en ts \2
D om R en ov
B ui ld in g
_k yl ek 9D
U H
U .rv t 6/
2/
:0 1:
P
M
GI121
ARCHITECTURAL SITE PLANS
STONE GROUP ARCHITECTS
600 EAST 7TH ST.
SIOUX FALLS, SD 57103
605-271-1144
TODD STONE
DOM RENOVATION FOR
SEMIPRIVATE ROOMS
HOT SPRINGS, SD
DOUG SPRINKLE
06/03/2025 JM/GB/TM TL/KK
SGA #211921
VA #568A4-21-208
BID DOCUMENTS
TRUE
NORTH
PLAN
NORTH
TRUE
NORTH
PLAN
NORTH
KEYNOTES
KEY VALUE KEYNOTE TEXT
1.01 CONTRACTOR'S ENTRANCE.
1.02 7'-0" CONSTRUCTION FENCE.
1.04 STAIR TO BE REMOVED. MAY RETAIN AS NECESSARY FOR USE DURING
DEMOLITION/CONSTRUCTION. CONFIRM W/ COR.
2.02 REMOVE LANDSCAPE ROCK FOR NEW SIDEWALK.
2.02A EXISTING LANDSCAPE ROCK TO REMAIN.
2.25 REMOVE MECH ELEMENT. CONCRETE SLAB TO REMAIN. SEE MECHANICAL.
2.26 REMOVE MECH ELEMENT, CONCRETE SLAB, CANOPY. SEE MECHANICAL.
23.02 MECH ELEMENT ON NEW CONCRETE PAD. SEE MECHANICAL.
23.03 MECH ELEMENT ON EXISTING CONCRETE PAD. SEE MECHANICAL.
32.01 NEW 4" CONCRETE SIDEWALK OVER GRANULAR SUB-BASE.
32.02 REPAIR/REPLACE LAWN WHERE DISTURBED BY CONSTRUCTION ACTIVITIES.CONFIRM FINAL
GRADING IS AWAY FROM BUILDING.
32.03 REPAIR/REPLACE DAMAGED CONCRETE WALK AND OR PARKING FROM CONSTRUCTION
ACTIVITIES.
32.04 REMOVE DUMPSTER.
32.05 REPAIR LANDSCAPE ROCK DISRUPTED BY CONSTRUCTION.
ISSUE # DESCRIPTION DATE
1 BID DOCUMENTS 06/03/2025
| Sheets |
| GI014 - CODE REVIEW, PCRA, ICRA, ISLM, GEN NOTES |
| GI100 - LIFE SAFETY PLAN - BASEMENT |
| GI101 - LIFE SAFETY PLAN - 1ST FLOOR |
| GI102 - LIFE SAFETY PLAN - 2ND FLOOR |
| GI121 - ARCHITECTURAL SITE PLANS |
| HA100 - HAZARDOUS ABATEMENT PLAN - BASEMENT |
| HA101 - HAZARDOUS ABATEMENT PLAN - 1ST FLOOR |
| HA102 - HAZARDOUS ABATEMENT PLAN - 2ND FLOOR |