The document is a set of architectural bid documents for a U.S. Department of Veterans Affairs Domiciliary Renovation project located in Hot Springs, South Dakota. The project involves renovating Building 8 to create semiprivate rooms, with a total of 116 detailed architectural sheets covering various aspects of the renovation including architectural, structural, mechanical, electrical, and accessibility design. The bid documents are dated 06/03/2025 and include comprehensive plans for demolition, new construction, floor plans, elevations, building sections, detailed accessibility requirements, and specifications for mechanical and electrical systems. The project is fully sprinklered and designed by Stone Group Architects, with structural engineering by Albertson Engineering and MEP engineering by West Plains Engineering.

The architectural drawings provide extensive accessibility details, including specific measurements and configurations for wheelchair accessibility, door clearances, bathroom fixtures, elevator specifications, and other ADA compliance requirements. The project scope appears to involve a comprehensive renovation of an existing VA domiciliary building, with careful attention to creating accessible and functional semiprivate room spaces. The project number is VA #568A4-21-208, and the bid documents are prepared for the VA's Office of Construction and Facilities Management, indicating this is a federal government infrastructure improvement project specifically focused on enhancing veteran housing and medical facilities.

View the file

Other files

File Type Posted
568A4-21-208 DOM Reno Rooms Bldg 8 QA 2.docx DOCX document
36C26325B0018 0003.docx DOCX document
36C26325B0018 0002.docx DOCX document
Johnson Controls Single Source Justification_Redacted.pdf PDF
2025.08.22_211921 Hot Springs Dom 8_Add-1.pdf PDF
568A4-21-208 DOM Reno Rooms Bldg 8 QA Final.docx DOCX document
Statement of Work - 568A4-21-208_Revised 8.22.25.pdf PDF
Building 8 Site Visit Sign-in.pdf PDF
36C26325B0018 0001.docx DOCX document
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part4.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part8.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part7.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part13.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part6.pdf PDF
Statement of Work - 568A4-21-208.pdf PDF
Wage Determination SD20250022 01.03.2025.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part11.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part5.pdf PDF
36C26325B0018.docx DOCX document
TMS 20939 VA Privacy Training.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part12.pdf PDF
Final Specs Combined 6-6-25.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part2.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part9.pdf PDF
Safety or Environmental Violations and EMR Information.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part10.pdf PDF
568A4-21-208 HOT SPRINGS VA DOMICILIARY RENO BLDG 9_Part3.pdf PDF
VAAR 852.219-75 Limitations on Subcontracting Cert of Compliance.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP - HOT SPRINGS, SD

TRUE

NORTH

PLAN

NORTH

VICINITY MAP - 500 N 5TH ST, HOT SPRINGS, SD 57747

TRUE

NORTH

PLAN

NORTH

PROJECT LOCATION

COVER IMAGE

VA FORM 08 - 6231

A

B

C

D

A

B

C

D

2 4 5 61

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O N

E Q

U A

R T

E R

I N

C H

O

N E

F O

O T

1/

4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O N

E H

A

LF

I N

C H

O

N E

F O

O T

1/

2"

'-0

T

H R

E E

Q U

A R

T E

R S

IN

C

H

O N

E F

O O

T

3/ 4"

'-0

6"

O N

E I

N C

H

O N

E F

O O

T

1"

'-0

6"

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

6"

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

6"

32 4 5 61

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

STRUCTURAL:

ALBERTSON ENGINEERING, INC.

3202 W. MAIN ST., #C

RAPID CITY, SD 57702

605-343-9606

MEP:

WEST PLAINS ENGINEERING, INC.

1750 RAND ROAD

RAPID CITY, SD 57702

605-348-7455

STEPHEN KILBER MIKE SIGMAN (ELEC)

MICHAEL HEINRICH (MECH)

C :\U se rs

\d .to ug as

\D oc um en ts \2

D om R en ov

B ui ld in g

_d ar rin tJ

Y

L.

rv t 6/

3/

:4 4:

A

M

U.S. DEPARTMENT OF VETERANS AFFAIRS

DOM RENOVATION FOR SEMIPRIVATE ROOMS

HOT SPRINGS, SD

VA #568A4-21-208

06/03/2025

BID DOCUMENTS

GI000

COVER SHEET

STONE GROUP ARCHITECTS

600 EAST 7TH ST.

SIOUX FALLS, SD 57103

605-271-1144

TODD STONE

DOM RENOVATION FOR

SEMIPRIVATE ROOMS

HOT SPRINGS, SD

DOUG SPRINKLE

06/03/2025 JM/GB/TM TL/KK

SGA #211921

VA #568A4-21-208

BID DOCUMENTS

SHEET INDEX

01 - GENERAL INFORMATION

GI000 COVER SHEET

GI001 ARCH / INT NOTES

GI011 ACCESSIBILITY DETAILS

GI012 ACCESSIBILITY DETAILS

GI013 ACCESSIBILITY DETAILS

GI014 CODE REVIEW, PCRA, ICRA, ISLM, GEN NOTES

GI100 LIFE SAFETY PLAN - BASEMENT

GI101 LIFE SAFETY PLAN - 1ST FLOOR

GI102 LIFE SAFETY PLAN - 2ND FLOOR

GI121 ARCHITECTURAL SITE PLANS

03 - HAZARDOUS MATERIALS

HA100 HAZARDOUS ABATEMENT PLAN - BASEMENT

HA101 HAZARDOUS ABATEMENT PLAN - 1ST FLOOR

HA102 HAZARDOUS ABATEMENT PLAN - 2ND FLOOR

03 - STRUCTURAL

SE-001 STRUCTURAL NOTES

SE-002 INSPECTION TABLES

SD-101 BUILDING BASEMENT DEMOLITION PLAN

SD-102 BUILDING FIRST FLOOR DEMOLITION PLAN

SD-103 BUILDING SECOND FLOOR DEMOLITION PLAN

SD-104 BUILDING ATTIC DEMOLITION PLAN

SD-105 BUILDING ROOF DEMOLITION PLAN

SE-101 BUILDING BASEMENT FOUNDATION PLAN

SE-102 BUILDING FIRST FLOOR FRAMING PLAN

SE-103 BUILDING SECOND FLOOR FRAMING PLAN

SE-104 BUILDING ATTIC FRAMING PLAN

SE-105 BUILDING ROOF FRAMING PLAN

SE-111 FIRST FLOOR PORCH FRAMING PLAN

SE-112 SECOND FLOOR PORCH FRAMING PLAN

SE-201 PORCH DEMOLITION & REPLACEMENT PHOTOGRAPHS

SE-202 PORCH DEMOLITION & REPLACEMENT PHOTOGRAPHS

SE-203 PORCH DEMOLITION & REPLACEMENT PHOTOGRAPHS

SE-204 MISCELLANEOUS ANNOTATED PORCH PHOTOGRAPHS

SE-501 BUILDING DETAILS

SE-502 BUILDING DETAILS

SE-503 BUILDING DETAILS

SE-504 BUILDING DETAILS

SE-505 BUILDING DETAILS

SE-511 PORCH DETAILS

SE-512 PORCH DETAILS

SE-513 TEMPORARY SHORING POSTS & DETAILS

SE-601 TYPICAL DETAILS & SCHEDULES

04 - ARCHITECTURAL DEMOLITION

AD100 DEMOLITION PLAN - BASEMENT

AD101 DEMOLITION PLAN - 1ST FLOOR

AD102 DEMOLITION PLAN - 2ND FLOOR

AD103 DEMOLITION PLAN - ATTIC

AD110 DEMOLITION RCP - BASEMENT

AD111 DEMOLITION RCP - 1ST FLOOR

AD112 DEMOLITION RCP - 2ND FLOOR

AD301 DEMOLITION SECTIONS

06 - ARCHITECTURAL

AE100 ARCHITECTURAL FLOOR PLAN - BASEMENT

AE101 ARCHITECTURAL FLOOR PLAN - 1ST FLOOR

AE102 ARCHITECTURAL FLOOR PLAN - 2ND FLOOR

AE103 ARCHITECTURAL FLOOR PLAN - ATTIC

AE104 ARCHITECTURAL DIMENSION PLAN - BASEMENT

AE105 ARCHITECTURAL DIMENSION PLAN - 1ST FLOOR

AE106 ARCHITECTURAL DIMENSION PLAN - 2ND FLOOR

SHEET INDEX

AE110 REFLECTED CEILING PLAN - BASEMENT

AE111 REFLECTED CEILING PLAN - 1ST FLOOR

AE112 REFLECTED CEILING PLAN - 2ND FLOOR

AE120 ROOF PLAN

AE201 EXTERIOR ELEVATIONS

AE301 BUILDING SECTIONS

AE311 WALL SECTIONS

AE401 ENLARGED SLOPE PLANS

AE501 DETAILS

AE502 DETAILS

AE503 DETAILS

AE504 DETAILS

AE601 SCHEDULES

AE701 CIRCULATION PLANS

AE702 CIRCULATION SECTIONS AND ELEVATIONS

08 - ARCHITECTURAL INTERIORS

AI100 FINISH AND SIGNAGE PLAN - BASEMENT

AI101 FINISH AND SIGNAGE PLAN - 1ST FLOOR

AI102 FINISH AND SIGNAGE PLAN - 2ND FLOOR

AI103 FINISH AND SIGNAGE SCHEDULES

AI450 INTERIOR ELEVATIONS

AI451 INTERIOR ELEVATIONS

AI501 CASEWORK AND FINISH DETAILS

AI801 ELEVATOR CAB DETAILS

10 - MECHANICAL

FX-101 FIRE PROTECTION PLANS

PD-101 BASEMENT & FIRST FLOOR PLUMBING DEMOLITION PLANS

PD-102 SECOND FLOOR PLUMBING DEMOLITION PLAN

PP-101 BELOW FLOOR BASEMENT & BASEMENT WASTE & VENT PLANS

PP-102 FIRST & SECOND FLOOR WASTE & VENT PLANS

PP-103 ATTIC WASTE & VENT PLAN

PP-104 BASEMENT & FIRST FLOOR PLUMBING PLANS

PP-105 SECOND FLOOR PLUMBING PLAN

PJ-101 DETAILS & SCHEDULES

MD-101 BASEMENT & FIRST FLOOR PIPING DEMOLITION PLANS

MD-102 SECOND FLOOR & ATTIC PIPING DEMOLITION PLANS

MD-103 BASEMENT & FIRST FLOOR HVAC DEMOLITION PLANS

MD-104 SECOND FLOOR & ATTIC HVAC DEMOLITION PLANS

MP-101 BASEMENT & FIRST FLOOR PIPING PLANS

MP-102 SECOND FLOOR & ATTIC PIPING PLANS

MH-101 BASEMENT & FIRST FLOOR HVAC PLANS

MH-102 SECOND FLOOR & ATTIC HVAC PLANS

MJ-101 SYMBOLS AND DETAILS

MJ-102 SCHEDULES

MJ-103 MECHANICAL SECTIONS

MJ-104 MECHANICAL SCHEDULES

11 - ELECTRICAL

ED-101 BASEMENT & FIRST FLOOR ELECTRICAL DEMOLITION PLANS

ED-102 SECOND FLOOR & ATTIC ELECTRICAL DEMOLITION PLANS

EL-101 BASEMENT & FIRST FLOOR LIGHTING PLANS

EL-102 SECOND FLOOR & ATTIC LIGHTING PLANS

EP-201 BASEMENT & FIRST FLOOR POWER PLANS

EP-202 FIRST FLOOR POWER PLAN

EP-203 SECOND FLOOR & ATTIC POWER PLANS

ES-001 FIBER SITE PLAN

ES-301 BASEMENT SIGNAL PLAN

ES-302 FIRST FLOOR SIGNAL PLAN

ES-303 SECOND FLOOR & ATTIC SIGNAL PLANS

EJ-401 ELECTRICAL DETAIL

EJ-402 ELECTRICAL DETAILS & SCHEDULES

EJ-403 ELECTRICAL SCHEDULES

EJ-404 ELECTRICAL SPECIFICATIONS

EJ-405 ELECTRICAL SPECIFICATIONS

EJ-406 ELECTRICAL SPECIFICATIONS

TOTAL SHEET COUNT: 116

ISSUE # DESCRIPTION DATE

1 BID DOCUMENTS 06/03/2025

TYPICAL DIMENSION LINE

BREAK LINE

DETAIL INDICATOR AND/OR

ENLARGED DRAWING CALLOUT

XX

X-XXX

XX

X-XXX

XX WALL SECTION INDICATOR

XX

X-XXX XX X-XXX EXTERIOR ELEVATION INDICATOR

ELEVATION / LEVEL INDICATOR

INTERIOR ELEVATION INDICATORX-XXX

XX

X-XXX

XX

XX

XX

XX

NORTH ARROW(S)

X.X KEYNOTE

X NEW GRID LINE

XXX

ROOM

XXX-# FINISH TYPE INDICATOR

XXX

XX

DRAWING TITLE

X"=X'-X"

XX

TRUE

NORTH

PLAN

NORTH

XX

X-XXX

BUILDING SECTION INDICATOR

XX

X-XXX

DETAIL INDICATOR

X-XXX

NORTH

EXISTING GRID LINEX

XX / XXX

SPOT ELEVATION INDICATOR

LEVEL TITLE

TYPICAL DRAWING BLOCK TITLE

DRAWING REFERENCE

X'-X"

ELEVATION / LEVEL INDICATOR

LEVEL TITLE

X'-X"

X' X"

SPOT COORDINATE INDICATOR

X'-X"

X" / 12"

SLOPE INDICATOR (PLAN)

X

XX

XX

REVISION AND/OR ISSUE INDICATOR

ROOF TYPE INDICATOR

WINDOW / STOREFRONT TYPE INDICATOR

PARTITION TYPE INDICATOR

DOOR / OPENING INDICATOR

(BORROWED LIGHT INCLUDED)

ROOM INDICATOR

EQUIPMENT TYPE INDICATOR

TYPE X

X'-X" A.F.F.

CEILING TYPE INDICATOR

XXX

X-XXX

XX

XX

OCCUPANT LOADXX

DETAIL INDICATOR AND/OR

ENLARGED DRAWING CALLOUT

SIGNAGE TYPE INDICATORXX

ARCH / INT ANNOTATION LEGEND (TAGS, SYMBOLS, AND INDICATORS)

REVISION AND/OR ISSUE CLOUD

SEE DRAWING LEGENDS FOR ADDITIONAL TYPES.

ARCH / INT MATERIAL LEGEND

BATT INSULATION

WOOD ROUGH (CONTINUOUS)

WOOD ROUGH (SPACED)

EXISTING CONSTRUCTION

TO BE REMOVED

NEW CONSTRUCTION

EARTH

EARTH (UNDISTURBED)

GYPSUM BOARD

CONCRETE

RIGID INSULATION

PLYWOOD

GRANULAR FILL

ASPHALT

ALUMINUM

STEEL

WOOD

BRICK

BLOCK

STONE

FIREPROOFING

LOOSE INSULATION

SAND

EXISTING CONSTRUCTION

TO REMAIN

SPRAY INSULATION

VINYL

EPOXY

ARCH / INT LINE TYPE LEGEND

HIDDEN LINE

CENTER LINE

GRID LINE

TYPICAL LINE

DISTANT LINE

ELEVATION / LEVEL LINE

LEADER LINE

CLEARANCE LINE

EASEMENT / SETBACK

PATH OF TRAVEL

FINISH EXTENT LINE

MATCHLINE

PROPERTY LINE

FINISH SEAM OR TRANSITION

TEMPORARY WEATHERPROOFING

UTILITIES LINEOVERHEAD LINE

SEE DRAWING LEGENDS FOR ADDITIONAL TYPES.

KEYNOTE LEADER LINE

TEMPORARY FIRE RATING

VA FORM 08 - 6231

A

B

C

D

A

B

C

D

2 4 5 61

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

STRUCTURAL:

ALBERTSON ENGINEERING, INC.

3202 W. MAIN ST., #C

RAPID CITY, SD 57702

605-343-9606

MEP:

WEST PLAINS ENGINEERING, INC.

1750 RAND ROAD

RAPID CITY, SD 57702

605-348-7455

STEPHEN KILBER MIKE SIGMAN (ELEC)

MICHAEL HEINRICH (MECH)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

D om R en ov

B ui ld in g

_k yl ek 9D

U H

U .rv t 6/

2/

:0 1:

P

M

GI001

ARCH / INT NOTES

STONE GROUP ARCHITECTS

600 EAST 7TH ST.

SIOUX FALLS, SD 57103

605-271-1144

TODD STONE

DOM RENOVATION FOR

SEMIPRIVATE ROOMS

HOT SPRINGS, SD

DOUG SPRINKLE

06/03/2025 JM/GB/TM TL/KK

SGA #211921

VA #568A4-21-208

BID DOCUMENTS

ARCH / INT ABBREVIATIONS

SYMBOLS

" INCH / INCHES

# POUND / NUMBER

& AND

' FOOT / FEET

+/- PLUS OR MINUS

< ANGLE

<< DOUBLE ANGLE

@ AT

CL CENTERLINE

d PENNEY

Ø ROUND OR DIAMETER

A

A/E ARCHITECT / ENGINEER

AAR AFTER ACTION REVIEW

AB ANCHOR BOLT

ABA ARCHITECTURAL BARRIERS ACT

ABBRV ABBREVIATION

ABV ABOVE

AC ASPHALTIC CONCRETE / AIR CONDITIONER /

ARCHITECTURAL CEILING

ACC ACCESSIBLE

ACCU AIR COOLED CONDENSING UNIT

ACM ALUMINUM COMPOSITE MATERIAL

ACOUS ACOUSTICAL

ACP ACOUSTICAL CEILING PANEL

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN / ARCHITECTURAL DEMOLITION

ADA AMERICANS WITH DISABILITIES ACT

ADD ADDENDUM

ADH ADHESIVE

ADJ ADJUSTABLE / ADJACENT / ADJOINING

AE ARCHITECTURAL ELEMENT / ARCHITECTURAL

ELEMENTS

AF ARCHITECTURAL FINISHES

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AG AGRICULTURAL / ARCHITECTURAL GRAPHICS

AHERA ASBESTOS HAZARD EMERGENCY RESPONSE ACT

AHJ AUTHORITY HAVING JURISDICTION

AI ARCHITECTURAL INTERIORS

AL ALUMINUM

ALN ALIGN

ALT ALTERNATIVE / ALTERNATE

ANOD ANODIZED

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

APPROX APPROXIMATE

APR APRIL

APX APPROXIMATE

ARCH ARCHITECT / ARCHITECTURAL

AS ARCHITECTURAL SITE

ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING,

AND AIR CONDITIONING ENGINEERS

ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS

ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

AUG AUGUST

AW ARCHITECTURAL WAYFINIDING

AWF ARCHITECTURAL WINDOW FILM

AWI ARCHITECTURAL WOODWORK INSTITUTE

AWP ACOUSTICAL WALL PANEL

B

B&B BOARD AND BATTEN / BALLED AND BURLAPPED

BATT BLANKET INSULATION / FIBERGLASS INSULATION

BD BOARD / BARN DOOR

BEV BEVELED

BF BIFOLD

BFF BELOW FINISH FLOOR

BIM BUILDING INFORMATION MODELING

BL BRICK LEDGE

BLDG BUILDING

BLKG BLOCK / BLOCKING

BM BEAM

BMRK BENCHMARK

BO BOTTOM OF

BOC BOTTOM OF CONCRETE

BOF BOTTOM OF FOOTING

BOW BOTTOM OF WALL

BRG BEARING

BRK BRICK

BRKT BRACKET

BRNG BEARING

BRZ BRONZE

BS BOTH SIDES

BSMT BASEMENT

BTM BOTTOM

BTWN BETWEEN

BUF BUILT UP FLOORING

BUR BUILT UP ROOFING

C

C CELSIUS

CA CONSTRUCTION ADMINISTRATION

CAB CABINET

CAD COMPUTER-AIDED DESIGN

CB CERAMIC BASE / CHALKBOARD

CC CENTER TO CENTER

CCW COUNTERCLOCKWISE

CD CONSTRUCTION DOCUMENTS / COILING DOOR / CIVIL

DEMOLITION

CEM CEMENT

CF CUBIC FEET/ CUBIC FOOT

CG CORNER GUARD / CIVIL GRADING

CH CHANNEL

CHR CHAIR RAIL

CI CIVIL IMPROVEMENTS

CIPC CAST-IN-PLACE CONCRETE

CIV CIVIL

CJ CONSTRUCTION JOINT / CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLKG CAULKING

CLO CLOSET

CLR CLEAR / CLEARANCE / CLEAR SPACE

CM CONSTRUCTION MANAGER / CENTIMETER /

CENTIMETERS

CMU CONCRETE MASONRY UNIT

CN CIVIL NODE / CIVIL NODES

CNTR COUNTER

CO CHANGE ORDER / CLEANOUT

ARCH / INT ABBREVIATIONS

COL COLUMN

COMB COMBINATION / COMBINE / COMBINED

COMP COMPOSITE / COMPOSITION

CONC CONCRETE

CONF CONFIRM / CONFIRMATION / CONFIRMED /

CONFERENCE

CONN CONNECT / CONNECTION

CONST CONSTRUCTION

CONT CONTINUOUS / CONTINUE / CONTINUED

CONTR CONTRACT / CONTRACTOR

COORD COORDINATE / COORDINATION / COORDINATOR

COR CONTRACTING OFFICER'S REPRESENTATIVE / CORIAN

CORR CORRUGATED / CORRIDOR

CP CAST PLASTIC / CIVIL PAVING

CPPT CARPET TILE

CPT CARPET

CR CRASH RAIL / CARD READER

CRS COURSE

CS CIVIL SITE / CENTRILE STERILE

CSI CONSTRUCTION SPECIFICATIONS INSTITUTE

CSMT CASEMENT

CT CERAMIC TILE / COMPUTED TOMOGRAPHY

CTB CERAMIC TILE BASE

CTR CENTER / CENTERED

CU CIVIL UTILITY / CIVIL UTILITIES

CV CENTER VISION

CW COLD WATER

CWT CERAMIC WALL TILE

D

D DEPTH / DEEP

DBL DOUBLE

DD DESIGN DEVELOPMENT / DUTCH DOOR

DEC DECEMBER

DEMO DEMOLITION / DEMOLISH

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DISP DISPENSER

DN DOWN

DO DITTO

DR DOOR

DS DOWNSPOUT

DTL DETAIL

DW DISHWASHER

DWG DRAWING

DWR DRAWER

DWTR DUMBWAITER

E

(E) EXISTING

E EAST

EA EACH

EC ELECTRICAL CONTRACTOR

ED ELECTRICAL DEMOLITION / EMERGENCY DEPARTMENT

EDT ELECTROSTATIC DISSIPATIVE TILE

EF EACH FACE

EFR EXISTING FINISH TO REMAIN / EXISTING FINSHES TO

REMAIN

EG END GUARD / EXISTING GRADE

EI ELECTRICAL INSTRUMENTATION

EIFS EXTERIOR INSULATION FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION / ELECTRICAL LIGHTING

ELEC ELECTRICAL

ELEV ELEVATION / ELEVATOR

ELVR ELEVATOR

EMER EMERGENCY

ENGR ENGINEER / ENGINEERED

ENL ENLARGED

EOP EDGE OF PAVEMENT

EP ELECTRICAL POWER

EPDM ETHYLENE PROPYLENE DIENE TERPOLYMER

MEMBRANE

EPS EXPANDED POLYSTYRENE BOARD

EPT EPOXY PAINT

EQ EQUAL

EQUIP EQUIPMENT

ES EACH SIDE / ELECTRICAL SITE

EST ESTIMATE

ET ELECTRICAL TELECOMMUNICATIONS

ETC ETCETERA

ETR EXISTING TO REMAIN

EV ELECTRIC VEHICLE

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXC EXCAVATE / EXCAVATION

EXH EXHAUST

EXP EXPANSION / EXPOSED

EXST EXISTING

EXT EXTERIOR

F

F/CC FIBERS PER CUBIC CENTIMETER

FA FIRE ALARM

FAB FABRICATE / FABRICATION / FABRICATED

FACP FIRE ALARM CONTROL PANEL

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDN FOUNDATION

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEB FEBRUARY

FEC FIRE EXTINGUISHER CABINET

FF FINISHED FLOOR

FFE FINISHED FLOOR ELEVATION

FG FULL GLASS / FINISHED GRADE

FGI FACILITY GUIDELINES INSTITUTE

FIN FINISH / FINISHED

FL FLOW LINE

FLDG FOLDING

FLR FLOOR / FLOORING

FLUOR FLUORESCENT

FO FACE OF

FOC FACE OF CONCRETE

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF STUD / FACE OF STRUCTURE

FP FLUSH PANEL / FIRE PROTECTION / FLOOR PLAN

FPS FIRE PULL STATION

FR FIRE RESISTANT / FRAME

FRMG FRAMING

ARCH / INT ABBREVIATIONS

FRP FIBERGLASS REINFORCED PANEL

FRT FIRE RETARDANT

FS FLOOR SINK / FOOT SCRAPER

FSA FIRE SYSTEM ANNUNCIATOR ALARM

FSP FIRE SYSTEM ANNUNCIATOR PANEL

FT FOOT / FEET / FIRE TREATED

FTG FOOTING

FURN FURNISH / FUNITURE / FURNACE

FURR FURRED / FURRING

FUT FUTURE

FV FIELD VERIFY

G

G GALLON / GALLONS / GAS

GA GAGE / GAUGE / GYPSUM ASSOCIATION

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR / GENERAL CONTRACT

GI GALVANIZED IRON / GENERAL INFORMATION

GL GLASS / GLAZING

GLU GLUE

GM GENERAL MANAGER

GR GENERAL RESOURCE / GENERAL RESOURCES

GRD GRADE

GSF GROSS SQUARE FOOTAGE / GROSS SQUARE FEET

GT GROUT

GWB GYPSUM WALL BOARD

GYP GYPSUM

H

H HIGH / HEIGHT

HA HAZARDOUS MATERIALS ASBESTOS

HAZ HAZARDOUS

HB HOSE BIB

HC HANDICAP / HOLLOW CORE / HAT CHANNEL

HD HEAVY DUTY

HDBD HARDBOARD

HDR HEADER

HDWD HARDWOOD

HDWR HARDWARE

HG HALF GLASS

HM HOLLOW METAL

HORZ HORIZONTAL

HPDL HIGH PRESSURE DECORATIVE LAMINATE

HR HOUR / HOURS / HANDRAIL / HUMAN RESOURCES

HSK HOUSEKEEPING

HT HEIGHT

HVAC HEATING, VENTILATION, AND AIR CONDITIONING

HW HOT WATER

HWC HYGIENIC WALL CLADDING

I

IB INTEGRAL BASE

IBC INTERNATIONAL BUILDING CODE

ICC INTERNATIONAL CODE COUNCIL

ICRA INFECTION CONTROL RISK ASSESSMENT

ICU INTENSIVE CARE UNIT

ID INSIDE DIAMETER / INSIDE DIMENSION / INTERIOR

DESIGN / INTERIOR DESIGNER / INTERIOR DEMOLITION

IEBC INTERNATIONAL EXISTING BUILDING CODE

IECC INTERNATIONAL ENERGY CONSERVATION CODE

IF INTERIOR FURNISHINGS

IFC INTERNATIONAL FIRE CODE

IFGC INTERNATIONAL FUEL GAS CODE

IG INTERIOR GRAPHIC / INTERIOR GRAPHICS

IHS INDIAN HEALTH SERVICES

ILSM INTERIM LIFE SAFETY MEASURES

IMC INTERNATIONAL MECHANICAL CODE

IN INCH / INCHES / INTERIOR DESIGN / INTERIOR

DESIGNER

INCL INCLUDE / INCLUDED / INCLUDING

INFO INFORMATION

INSP INSPEC / INSPECTION / INSPECTOR

INSTR INSTRUCTION / INSTRUCTIONS

INSUL INSULATE/ INSULATED / INSULATION

INT INTERIOR

IPC INTERNATIONAL PLUMBING CODE

IRC INTERNATIONAL RESIDENTIAL CODE

IT INFORMATION TECHNOLOGY

J

JAN JANITOR / JANUARY

JSN JOINT SCHEDULE NUMBER

JST JOIST

JT JOINT

JUL JULY

JUN JUNE

JV JOINT VENTURE

K

KCJ KEYED CONSTRUCTION JOINT

KM KILOMETER / KILOMETERS

KO KNOCK OUT

L

L LENGTH / LONG

LA LANDSCAPE ARCHITECT

LAB LABORATORY

LAM LAMINATE / LAMINATED

LAND LANDSCAPE

LAV LAVATORY

LB POUND

LBC LIVING BUILDING CHALLENGE

LD LANDSCAPE DEMOLITION / LANDSCAPE DESIGN /

LANDSCAPE DESIGNER

LDR LADDER

LDRP LABOR DELIVERY RECOVERY POST PARTUM

LED LIGHT EMITTING DIODE

LEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN

LF LINEAR FEET

LG LANDSCAPE GRADING

LH LEFT HAND

LIN LINOLEUM

LKR LOCKER

LL LOWER LEVEL / LANDSCAPE LIGHTING

LOC LOCATION

LOGCAT LOGISTICAL CATEGORY

LONG LONGITUDINAL

LP LANDSCAPE PLANTING

LR LANDSCAPE RELOCATION

LS LIFE SAFETY / LANDSCAPE SITE

LT LIGHT

LTC LONG TERM CARE

LVC LOW VOLUME CHANGE

ARCH / INT ABBREVIATIONS

LVR LOUVER

LVT LUXURY VINYL TILE

M

M METER / METERS

MAR MARCH

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MAY MAY

MC MEDICINE CABINET / MECHANICAL CONTRACTOR

MCT MARMOLEUM COMPOSTIION TILE

MD MECHANICAL DEMOLITION

ME MATCH EXISTING

MECH MECHANICAL

MEF MATCH EXISTING FINISH / MATCH EXISTING FINISHES

MEMB MEMBRANE

MEZZ MEZZANINE

MFR MANUFACTURE / MANUFACTURER

MH MECHANICAL HVAC / MANHOLE

MI MILE / MILES / MECHANICAL INSTRUMENTATION

MICU MEDICAL INTENSIVE CARE UNIT

MIN MINIMUM / MINUTE / MINUTES

MISC MISCELLANEOUS

MM MILLIMETER / MILLIMETERS

MNTG MOUNTING

MO MASONRY OPENING

MP MECHANICAL PIPING

MR MIRROR

MRI MAGNETIC RESONANCE IMAGING

MS MECHANICAL SITE

MT METAL TRIM

MTL METAL

MULL MULLION

N

(N) NEW

N NORTH

NA NOT APPLICABLE

NAICS NORTH AMERICAN INDUSTRY CALSSIFICATION SYSTEM

NCARB NATIONAL COUNCIL OF ARCHITECTURAL

REGISTRATION BOARDS

NCS NATIONAL CAD STANDARD

NESHAP NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR

POLLUTANTS

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NGC NATIONAL GYPSUM COMPANY

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NOV NOVEMBER

NSF NET SQUARE FOOTAGE / NET SQUARE FEET

NSN NATIONAL STOCK NUMBER

NTS NOT TO SCALE

NV NARROW VISION

O

OA OVERALL

OC ON CENTER

OCT OCTOBER

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED; CONTRACTOR INSTALLED

OFF OFFICE

OFOI OWNER FURNISHED; OWNER INSTALLED

OH OVERHEAD

OPG OPENING

OPNG OPENING

OPP OPPOSITE

OR OPERATING ROOM

ORD OVERFLOW ROOF DRAIN / ORDINANCE

ORIG ORIGINAL

OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION

OT OCCUPATIONAL THERAPY

OVHD OVERHEAD

OZ OUNCE

P

P PAINT

PACU POST ANESTHETIC CARE UNIT

PAR PARALLEL

PART PARTITION

PC PLUMBING CONTRACTOR

PCB POLYCHLORINATED BIPHENYLS

PCF POUNDS PER CUBIC FOOT

PCRA PRE-CONSTRUCTION RISK ASSESSMENT

PD PRE-DESIGN / POCKET DOOR / PLUMBING DEMOLITION

PED PEDISTAL

PEM PRE-ENGINEERED METAL

PEMB PRE-ENIGNNERED METAL BUILDING

PERF PERFORATED

PERP PERPENDICULAR

PL PLATE / PLASTIC / PROPERTY LINE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLT PLATE

PLUMB PLUMBING

PLYWD PLYWOOD

PNL PANEL

PP PLUMBING PIPING

PR PAIR / PROPOSAL REQUEST

PRCST PRECAST

PREFAB PREFABRICATE / PREFABRICATED

PREFIN PREFINISH / PREFINISHED

PS PLUMBING SITE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED / PORCELAIN TILE / PHYSICAL

THERAPY

PTD PAPER TOWEL DISPENSER / PAINTED

PTN PARTITION

PTR PAPER TOWEL RECEPTACLE

PVC POLYVINYL CHOLORIDE

PW PLYWOOD

PWT PORCELAIN WALL TILE

Q

QAQC QUALITY ASSURANCE & QUALITY CONTROL

QT QUARRY TILE / QUART / QUARTS

QTY QUANTITY

QTZ QUARTZ

R

R RADIUS / RISER / INSULATING VALUE

RAG RETURN AIR GRILLE

ARCH / INT ABBREVIATIONS

RB RESILIENT BASE

RBR RUBBER

RC RESILIENT CHANNEL / RESPIRATORY CARE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REBAR REINFORCING BAR

REC RECESSED

REF REFERENCE / REFRIGERATOR

REINF REINFORCED / REINFORCING / REINFORCEMENT

REM REMOVE / REMVOVED

REQ REQUIRE

REQD REQUIRED

RES RESINOUS

RESIL RESILIENT

RET RETURN / RETURNED

REV REVISION / REVISIONS / REVISED

RF RESILIENT FLOORING

RFG ROOFING

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RI RIGID INSULATION

RL RIDGE LINE

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RR RESTROOM

RVS REVERSE / REVERSE SIDE

RWC RIGID WALL COVERING

RWL RAIN WATER LEADER

S

S SOUTH

SAD SUPPLY AIR DIFFUSER

SAFB SOUND ATTENUATION FIRE BLANKETS

SAN SANITARY

SB SPLASH BACK / STRUCTURAL SUBSTRUCTURE

SC SOLID CORE / SPECIALTY COATING

SCHED SCHEDULE

SCONC SEALED CONCRETE

SCR SHOWER CURTAIN ROD

SD SOAP DISPENSER / SCHEMATIC DESIGN / SLIDING

DOOR / STRUCTURAL DEMOLITION

SDG SIDING

SDVOSB SERVICE-DISABLED VETERAN-OWNED SMALL

BUSINESS

SEC SECOND / SECONDS

SECT SECTION / SECTIONS

SEP SEPTEMBER

SEPS SPACE & EQUIPMENT PLANNING SYSTEM

SF SQUARE FOOTAGE / SQUARE FEET / STRUCTURAL

FRAMING

SG SAFETY GLASS

SGA STONE GROUP ARCHITECTS

SHPO STATE HISTORIC PRESERVATION OFFICE

SHT SHEET

SHTHG SHEATHING

SHWR SHOWER

SICU SURGICAL INTENSIVE CARE UNIT

SIM SIMILAR

SL SHAFT LINER

SLDG SLIDING

SLNT SEALANT

SND SANITARY NAPKIN DISPENSER

SNX SANIARY NAPKIN DISPOSAL

SOG SLAB ON GRADE

SPEC SPECIFICATION / SPECIFICATIONS

SQ SQUARE

SRT STUDDED RUBBER TILE

SS SOLID SURFACE / STRUCTURAL SITE

SSM SOLID SURFACE MATERIAL

SST STAINLESS STEEL

ST STREET / SOUND TRANSMISSION

STAG STAGGERED

STC SOUND TRANSMISSION CLASS

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURE / STRUCTURAL

SUSP SUSPENDED

SV SHEET VINYL

SW SHEARWALL

SYM SYMMETRICAL

T

T TREAD

T&B TOP AND BOTTOM

T&G TOUNGE AND GROOVE

TA TELECOMMUNICATIONS AUDIO VISUAL

TB TOWEL BAR / TACKBOARD

TBD TO BE DETERMINED

TC TELECOMMUNICATIONS CLOCK

TCNA TILE COUNCIL OF NORTH AMERICA

TD TRAVEL DISTANCE

TEL TELEPHONE / TELEMETRY

TEMP TEMPORARY / TEMPERED

TER TERRAZZO

TFE TOP FOOTING ELEVATION

TG TEMPERED GLASS

THD THREA / THREADED / THREADS

THK THICKNESS

THRU THROUGH

TI TELECOMMUNICATIONS INTERCOM

TIL TECHNICAL INFORMATION LIBRARY

TKBD TACKBOARD

TL TILE

TLT TOILET

TM TELECOMMUNICATIONS MONITORING

TMV THERMOSTATIC MIXING VALVE

TN TELECOMMUNICATIONS DATA NETWORKS

TO TOP OF

TOB TOP OF BEAM

TOC TOP OF CONCRETE / TOP OF CURB

TOD TOP OF DECK

TOF TOP OF FOOTING / TOP OF FOUNDATION

TOJ TOP OF JOIST

TOM TOP OF MASONRY

TOP TOP OF PIER

TOS TOP OF SLAB / TOP OF STEEL

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TPH TOILET PAPER HOLDER

TPO THERMOPLASTIC POLYOLEFIN

TPTN TOILET PARTITION

ARCH / INT ABBREVIATIONS

TRANS TRANSVERSE / TRANSPARENT

TS TUBE STEEL / TRANSITION STRIP

TT TELECOMMUNITCATIONS TELEPHONE

TV TELEVISION

TXV THERMAL EXPANSION VALVE

TYP TYPICAL / TYPICALLY

U

UCL UNDER CABINET LIGHT

UDS UNIFORM DRAWING SYSTEM

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITERS LABORATORIES

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UON UNLESS OTHERWISE NOTED

USGBC UNITED STATES GREEN BUILDING COUNCIL

UTIL UTILITY / UTILITIES

UTL UTILITY / UTILITIES

V

V SHEAR

VA VETERAN AFFAIRS

VAR VARIES

VB VAPOR BARRIER / VINYL BASE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VFY VERIFY

VIF VERIFY IN FIELD

VISN VETERANS INTEGRATED SERVICES NETWORK

VR VAPOR RETARDER

VWC VINYL WALL COVERING

VWT VINYL WALL TILE

W

(W) WIDE FLANGE

W WEST / WIDTH / WIDE / WIDE FLANGE

W/ WITH

W/O WITHOUT

WA WEDGE ACHOR

WB WOOD BASE

WC WATER CLOSET

WD WOOD / WOODWORK

WDW WINDOW

WF WIDE FLANGE

WG WALL GUARD

WH WATER HEATER

WI WROUGHT IRON

WL WIND LOAD

WP WATERPROOF / WATERPROOFING

WR WATER RESISTANT

WSCT WAINSCOT

WSF WELDED SHEET FLOORING

WT WEIGHT / WINDOW TREATMENT

WWF WELDED WIRE FABRIC

Y

YD YARD / YARDS

GENERAL ACCESSIBILITY NOTES

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER BEFORE

PROCEEDING WITH THE WORK.

B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

C. ALL CONSTRUCTION AND RENOVATION SHALL MEET THE ARCHITECTURAL BARRIERS ACT

ACCESSIBILITY STANDARD (ABAAS).

D. SUPPLEMENTAL TO THE (ABAAS), CONSTRUCTION & RENOVATION IN HEALTH FACILITIES OF THE

DEPARTMENT OF VETERAN AFFAIRS (VA) SHALL COMPLY WITH THE VA BARRIER FREE DESIGN

STANDARD: A SUPPLEMENT TO THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS

(PG-18-13).

VA BARRIER FREE DESIGN STANDARDS THAT ARE

MORE RESTRICTIVE THAN ABAAS & IBC REQUIREMENTS

MINIMUM REQUIREMENTS

• SITES - PARKING SPACES ACCESSIBLE 1% GREATER THAN ABAAS

• SPINAL CORD INJURY/DISORDER (SCI/D) FACILITIES: 0.2

ACCESSIBLE SPACES PER INPATIENT BED; 0.5 PER

LONG-TERM CARE BED; 5.6 PER OUTPATIENT EXAM ROOM.

DEDICATED FOR SCI/D PATIENTS

• HOSPITAL OUTPATIENT FACILITIES 10% OF TOTAL SPACES

• REHABILITATION AND OUTPATIENT

PHYSICAL THERAPY FACILITIES 20% OF TOTAL SPACES

• BUILDING-ACCESSIBLE SEATING, ASSEMBLY AREAS 1% GREATER THAN ABAAS

ACCESSIBLE ROUTE

• WIDTH, MIN. PATIENT CARE AREAS 6'-0"

• WIDTH, MIN. ADMINISTRATIVE AREA 5'-0"

• SLOPE, MAXIMUM (INCLUDING PARKING SPACES) 1:50 (2%)

• MINIMUM GRADIENT OF WALK REQUIRING REST

AREAS EVERY 200' 1:50 (2%)

• TURNING RADIUS 5'-6"

• TURNING RADIUS, BARIATRIC 6'-0"

• T-SHAPED TURNING SPACE 5'-6" x 5'-6"

• T-SHAPED TURNING SPACE, BARIATRIC 6'-0" x 6'-0"

FLOOR SURFACES

• CHANGES IN LEVEL NOT PERMITTED ON SCI/D FLOORS

• CARPET CUSHION OR PADDING NOT PERMITTED

PARKING & PASSENGER LOADING ZONES

• ACCESS AISLE REQUIREMENT FOR ACCESSIBLE

PARKING SPACES 5'-0" EACH SIDE

• PASSENGER LOADING AREA

"COMMUNICATION SYSTEM" FOR ASSISTANCE AT SCI UNITS YES

CURB RAMPS

• WIDTH, MINIMUM 4'-0"

RAMPS

• MAXIMUM SLOPE 1:20

• MAXIMUM LENGTH, WITHIN RANGE OF 1:33 - 1:26 40'

• MAXIMUM LENGTH, WITHIN RANGE OF 1:25 - 1:20 35'

• MINIMUM CLEAR WIDTH 4'-0"

• MINIMUM SIZE LEVEL LANDING, WHERE DOORS

SWING INTO LANDING 6'-0" X 6'-0"

STAIRS

• HANDRAIL HEIGHT 34"

ELEVATOR (PASSENGER)

• MINIMUM WIDTH OF ELEVATOR DOORS 4'-0"

• MINIMUM CAR SIZE 8'-0" X 6'-2" PLATFORM SIZE

• DOUBLE SET OF HANDRAILS YES

WINDOWS

• SILL HEIGHT IN PATIENT BEDROOMS 24" MAXIMUM

DOORS & DOORWAYS

• PATIENT CARE DELIVERY AREAS WITH PATIENT BED,

STRETCHER OR GURNEY ACCESS, MINIMUM WIDTH 5'-0" SLIDER TYPE

• PATIENT CARE DELIVERY AREAS WITH PATIENT BED, 5'-6" (4'-0" + 1'-6")

STRETCHER OR GURNEY ACCESS, MINIMUM WIDTH,

BARIATRIC 6'-0"

• PATIENT CARE BUILDING ENTRY, EXIT, AND DEPARTMENT

ENTRY DOORS MINIMUM WIDTH. 4'-0"

WATER CLOSETS - INPATIENT NURSING UNITS

• GRAB BAR CONFIGURATION: DOUBLE SWING-UP BARS FOR

ALL PATIENT TOILETS/SHOWER ROOMS ON NURSING UNITS

W/ INTEGRAL TOILET PAPER DISPENSER.

• DISTANCE FROM TOILET CENTERLINE TO SIDE WALL 3'-0"

• DISTANCE FROM EDGE OF TOILET TO SIDE WALL, BARIATRIC 3'-0"

TOILET STALLS

• MINIMUM ACCESSIBLE STALL SIZE 5'-6" X 6'-0"

• MINIMUM SIZE WHEELCHAIR "FRONT-TRANSFER" STALL 3'-6" X 6'-0"

• GRAB BARS REQUIRED IN ALL STALLS

SHOWER STALLS (PATIENT)

• MINIMUM STALL DIMENSIONS 4'-0" X 4'-0"

• MINIMUM BARIATRIC STALL DIMENSIONS 4'-0" X 6'-0"

• GRAB BARS HORIZONTAL PLUS VERTICAL BARS

TOILET ROOMS

• INPATIENT BEDROOM TOILET ROOMS,

MINIMUM WIDTH OF TOILET ROOM ENTRANCE DOORS 48"

CAFETERIAS

• KNEE CLEARANCE, FOR MINIMUM 5% TABLES 2'-3" & 2'-5" FOR AT LEAST 5%

• CUTLERY AND SUPPLY HEIGHT 40" - 48"

HEALTH CARE FACILITIES

• MEDICAL/SURGICAL NURSING UNITS,

PERCENT OF PATIENT BEDROOMS ACCESSIBLE 100%

Figure 302.2 Carpet Pile Height

Figure 303.2 Vertical Change in Level

1/ 2" m ax

1/ 4" m ax

Figure 302.3 Elongated Openings in Floor or

Ground Surfaces d ir ec ti o n o f tr av el lo n g d im d o m in an t p er p en d ic u la r to

1/2" max dominant direction of travel

Figure 303.3 Beveled Change in Level

1/

1/

1/

1/

Figure 304.3.1.2 Circular Turning Space - Existing

Buildings Size and Overlap

Figure 304.3.1.1 Circular Turning Space - New Buildings Size and Overlap

0'

0" m ax

Overlap of knee and toe clearance Overlap of knee and toe clearance

6.

2.

2' m ax

P er ø 5'-7" min ø 5'-0" min

Figure 304.3.2.2 T-Shaped Turning Space New Buildings - Size and Overlap ar m ar m base

Figure 304.3.2.1(A) T-Shaped Turning Space New Buildings - Option 1 ar m ar m base

68" min min

16" min

36" min

16" m in m in36 m in

Figure 304.3.2.1(B) T-Shaped Turning Space New Buildings - Option 2 ar m ar m base

64" min min

11" min

42" min

11" m in m in m in

Figure 304.3.2.1(C) T-Shaped Turning Space New Buildings - Option 3 ar m ar m base

64" min min

12" min

40" min

12" m in m in m in

60" min min

12" min

36" min

12" m in36 m in m in

Figure 305.3.2 Clear Floor or Ground

Space- Existing Buildings

Figure 305.5 Position of Clear Floor or Ground Space

Figure 305.7.1 Maneuvering Clearance in an

Alcove, Forward Approach

Figure 305.7.2 Maneuvering Clearance in an

Alcove, Parallel Approach

(a) forward

(b) parallel

Figure 305.3.1 Clear Floor or Ground Space- New Buildings

52" min m in

48" min m in

30" min m in

48" min m in

36" min

X

4"

60" min

X

5"

Figure 306.2 Toe Clearance

Figure 306.3 Knee Clearance

(b) plan

(a) elevation

9"

6" max m in

17"- 25"

(b) plan

(a) elevation m in

25" max

11" min

8" min m in

Figure 307.2 Limits of Protruding Objects

4" max

X

7"

X

0"

Figure 307.3 Post-Mounted Protruding Objects

(b)(a)

0" 12" max 12" max m ax X > 12"

X > 12" m in

Figure 307.4 Vertical Clearance

M ax

X

Figure 308.3.1 Unobstructed Side Reach

Figure 308.3.2 Unobstructed High Side Reach

Figure 308.2.2 Obstructed High Forward Reach

Figure 308.2.1 Unobstructed

Forward Reach

(a) (b)

(b)(a) m in m ax m ax

20" max m ax

20"- 25" max

10" max m in m ax

10" max 10" - 24" max m ax m ax m ax m ax

B U

IL

D

IN

G

B L

O C

K S

Figure 403.5.2 Clear Width at Turn Existing Buildings

Figure 403.5.1 Clear Width of an Accessible Route

(a) 180 degree turn

(b) 180 degree turn

(Exception)

Figure 403.5.2.1 Clear Width at Turn

(A) 180 degree turn

New Buildings - Option 1 m in

(B) 180 degree turn

New Buildings - Option 2 m in

(C) 180 degree turn

New Building - Option 3 m in

38" min m in

36" min m in

Figure 403.5.3.1 Clear Width At 90-Degree Turn

36" min m in

4" min 28" min

4" m in m in

Figure 403.5.3.2 Clear Width At 90-Degree Turn

Existing Buildings

36" min m in

Figure 403.5.3.1 Clear Width At 90-Degree Turn

Existing Buildings

36" min m in

36" min

X<52"

36" min 42" min

X<52"

42" min 43" min

X<52"

43" min m in m in

42" min

X<48"

42" min 36" min

X<48"

36" min

32" min

36" min

32" min

36" min m ax m in m ax

(a) 90 degree trun

New Building - Option 1

(b) 90 degree trun

New Building - Option 2

(c) 90 degree trun

New Building - Option 3

A C

C E

S S

IB

L

E R

O U

T E

S

Figure 405.7 Ramp Landings landing landingramp run ramp run landing ra m p ru n

(a) straight

(b) change in direction

60" Min 60" Min 60" Min

M in

Figure 405.9.1 Extended Floor or Ground Surface

Edge Protection

Figure 405.9.2 Curb or Barrier Edge Protection

Figure 406.2 Counter Slope of Surfaces Adjacent to Curb Ramps curb ramp slope adjoining surface maximum slope

Figure 406.3 Sides of Curb Ramps flared sides 1:10 max slope slope slope

Figure 406.2 (A) Perpendicular Curb Ramp

Where a pedestrian circulation path crosses, flared sides sloped 1:10

48" Min

M in

Curb of ramp flares painted if adjacent curb is painted (Section 406.5.6)

Building or sidewalk edge

Figure 406.2 (B) Perpendicular Curb Ramp

M in

48" Min Building or sidewalk edge

Planting area Planting area

Figure 406.3

(A) Parallel curb ramp

M in

48" Min Building or sidewalk edge

Figure 406.3

(B) Parallel curb ramp

Building or sidewalk edge

Planting area

M in

48" Min

Figure 406.4 Landings at the Top of Curb Ramps

Figure 406.6 Diagonal or Corner Type Curb Ramps

Figure 406.7 Islands in Crossings

(a) cut through an island

(b) curb ramp at island

24" Min

24" Min

48" Min at least as wide as curb ramp

Figure 705.6 (A) Extent of Detectable Warning-

Perpendicular m in m in

Figure 705.6 (B) Extent of Detectable Warning-

Returned Curb

Figure 705.6 (C) Extent of Detectable Warning-

Parallel m in

(section 403.5)

32" -36" min

M in at least as wide as curb ramp

M in

36" Min full width of the curb ramp full width of the curb ramp at le as t as w id e as r am p r u n

12" Min 12" Min

X

C U

R B

S A

N D

R A

M P

S m in

48" min

Figure 1104.1.1 Clear Floor Space

For type B Unit

(a) front or rear entry

(b) side entry

Figure 802.1.3 Depth of Wheelchair Spaces in

Assembly Area

(a) single space

(b) two spaces

Figure 802.1.2 Width of Wheelchair Spaces in

Assembly Area

36" min 33" min 33" min m in m in

Figure 802.4(a) Depth of Wheelchair Spaces in Assembly Area - New Building m in

W H

E E

L C

H A

IR

S

P A

C E

S

VA FORM 08 - 6231

A

B

C

D

A

B

C

D

2 4 5 61

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

STRUCTURAL:

ALBERTSON ENGINEERING, INC.

3202 W. MAIN ST., #C

RAPID CITY, SD 57702

605-343-9606

MEP:

WEST PLAINS ENGINEERING, INC.

1750 RAND ROAD

RAPID CITY, SD 57702

605-348-7455

STEPHEN KILBER MIKE SIGMAN (ELEC)

MICHAEL HEINRICH (MECH)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

D om R en ov

B ui ld in g

_k yl ek 9D

U H

U .rv t 6/

2/

:0 1:

P

M

GI011

ACCESSIBILITY DETAILS

STONE GROUP ARCHITECTS

600 EAST 7TH ST.

SIOUX FALLS, SD 57103

605-271-1144

TODD STONE

DOM RENOVATION FOR

SEMIPRIVATE ROOMS

HOT SPRINGS, SD

DOUG SPRINKLE

06/03/2025 JM/GB/TM TL/KK

SGA #211921

VA #568A4-21-208

BID DOCUMENTS

Figure 602.2.1 (A) Clear Floor Space at Wheelchair Drinking

Fountains

Figure 602.2.1 (B) Clear Floor Space at Wheelchair Drinking Fountains Primarly for

Children's use Exception

Children Adults

Figure 602.2.3 Wheelchair Drinking

Fountain Spout Height and Location

-4 m ax

-4 m ax

Figure 602.3.2 Standing use Drinking Fountain Spout Height and Location

Figure 602.3.3 Drinking Fountain

Spout Location m ax m ax

Children Adults

5" max (602.2.4)

15" min for Adults

D R

IN

K

IN

G

F O

U N

T A

IN

S48" min min

15" m in

Figure 903.3 Bench Size

And Clear Space

42" min

Figure 903.4 Bench Back Support

(a) (b) m in

2" m ax

2 1/2" max

Figure 904.4.1 Sales And Service Counters - Parallel Approach

Figure 904.4.2 Sales And Service Counters - Forward Approach

Elevation

Plan

30" min m ax m ax

Elevation

Plan

36" min m ax m ax

B U

IL

T

-I N

E L

E M

E N

T S

Sanitary Napkin Disposal

Sanitary Napkin Dispenser m ax

Soap Dispenser

Paper Towel Dispenser

T .O

. d is p en se r

O P

G m ax

Baby Changing Station to B

.O m in to h ig h es t p ar t m ax

LINE OF WALL

Coat/Robe Hook

4' -0

A

C C

5' -4

T

Y P

Door Viewer

3' -7

A

C C

5' -0

T

Y P

Mirror Height to g la ss

Fire Extinguisher Cabinet m ax t o t h e h an d le m ax

Fire Extinguisher m ax t o t h e h an d le m ax

Hand Dryer

Trash Receptacle m ax w o rk s u rf ac e o f w o rk s u rf ac e

T .O

. o p er ab le p o rt io n m ax

Toilet Seat Cover Dispenser

M O

U N

T

IN

G H

E

IG

H T

S

Figure 502.2 Vehicle Parking Spaces

Figure 502.3 Parking Space Access Aisle

Figure 503.3 Passenger Loading Zone Access Aisle

Figure 504.2 Treads and Risers

Figure 504.5 Stair Nosings

Figure 505.4 Handrail Height

Figure 505.5 Handrail

Clearance

Figure 505.6 Horizontal

Projections Below Gripping Surface

Figure 505.7.2 Handrail Non-Circular Cross Section

Figure 505.10.1 Top and Bottom Handrail

Extensions at Ramps

Figure 505.10.2 Top Handrail

Extension at Stairs

Figure 505.10.3 Bottom Handrail

Extension at Stairs

(a) radius of tread edge

(typical for all profiles)

(b) angled riser

(c) curved nosing

(d) beveled nosing

(a) car

(b) van

(a) stairs

(b) ramps

(c) walking surfaces Note: X = tread depth

96" min 132" min

F u ll L en g th o f P ar ki n g

S p ac e

60" min area to be marked

Vehicle Pull-up Space

Full Length of m in curb line area to be marked 7" m ax

4" m in

11" min

1 1/2" max 1 1/2" max radius 1/2" max

30° max

"34

1 1/2" min

1/

2" m in

4" - 6 1/4" perimeter

2 1 /4" m ax

2 1/4" max

12" min 12" min

12" min

XX

G E

N E

R A

L S

IT

E

A N

D B

U

IL

D

IN

G E

L E

M E

N T

S

GENERAL ACCESSIBILITY NOTES

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER BEFORE

PROCEEDING WITH THE WORK.

B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

C. ALL CONSTRUCTION AND RENOVATION SHALL MEET THE ARCHITECTURAL BARRIERS ACT

ACCESSIBILITY STANDARD (ABAAS).

D. SUPPLEMENTAL TO THE (ABAAS), CONSTRUCTION & RENOVATION IN HEALTH FACILITIES OF THE

DEPARTMENT OF VETERAN AFFAIRS (VA) SHALL COMPLY WITH THE VA BARRIER FREE DESIGN

STANDARD: A SUPPLEMENT TO THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS

(PG-18-13).

VA BARRIER FREE DESIGN STANDARDS THAT ARE

MORE RESTRICTIVE THAN ABAAS & IBC REQUIREMENTS

MINIMUM REQUIREMENTS

• SITES - PARKING SPACES ACCESSIBLE 1% GREATER THAN ABAAS

• SPINAL CORD INJURY/DISORDER (SCI/D) FACILITIES: 0.2

ACCESSIBLE SPACES PER INPATIENT BED; 0.5 PER

LONG-TERM CARE BED; 5.6 PER OUTPATIENT EXAM ROOM.

DEDICATED FOR SCI/D PATIENTS

• HOSPITAL OUTPATIENT FACILITIES 10% OF TOTAL SPACES

• REHABILITATION AND OUTPATIENT

PHYSICAL THERAPY FACILITIES 20% OF TOTAL SPACES

• BUILDING-ACCESSIBLE SEATING, ASSEMBLY AREAS 1% GREATER THAN ABAAS

ACCESSIBLE ROUTE

• WIDTH, MIN. PATIENT CARE AREAS 6'-0"

• WIDTH, MIN. ADMINISTRATIVE AREA 5'-0"

• SLOPE, MAXIMUM (INCLUDING PARKING SPACES) 1:50 (2%)

• MINIMUM GRADIENT OF WALK REQUIRING REST

AREAS EVERY 200' 1:50 (2%)

• TURNING RADIUS 5'-6"

• TURNING RADIUS, BARIATRIC 6'-0"

• T-SHAPED TURNING SPACE 5'-6" x 5'-6"

• T-SHAPED TURNING SPACE, BARIATRIC 6'-0" x 6'-0"

FLOOR SURFACES

• CHANGES IN LEVEL NOT PERMITTED ON SCI/D FLOORS

• CARPET CUSHION OR PADDING NOT PERMITTED

PARKING & PASSENGER LOADING ZONES

• ACCESS AISLE REQUIREMENT FOR ACCESSIBLE

PARKING SPACES 5'-0" EACH SIDE

• PASSENGER LOADING AREA

"COMMUNICATION SYSTEM" FOR ASSISTANCE AT SCI UNITS YES

CURB RAMPS

• WIDTH, MINIMUM 4'-0"

RAMPS

• MAXIMUM SLOPE 1:20

• MAXIMUM LENGTH, WITHIN RANGE OF 1:33 - 1:26 40'

• MAXIMUM LENGTH, WITHIN RANGE OF 1:25 - 1:20 35'

• MINIMUM CLEAR WIDTH 4'-0"

• MINIMUM SIZE LEVEL LANDING, WHERE DOORS

SWING INTO LANDING 6'-0" X 6'-0"

STAIRS

• HANDRAIL HEIGHT 34"

ELEVATOR (PASSENGER)

• MINIMUM WIDTH OF ELEVATOR DOORS 4'-0"

• MINIMUM CAR SIZE 8'-0" X 6'-2" PLATFORM SIZE

• DOUBLE SET OF HANDRAILS YES

WINDOWS

• SILL HEIGHT IN PATIENT BEDROOMS 24" MAXIMUM

DOORS & DOORWAYS

• PATIENT CARE DELIVERY AREAS WITH PATIENT BED,

STRETCHER OR GURNEY ACCESS, MINIMUM WIDTH 5'-0" SLIDER TYPE

• PATIENT CARE DELIVERY AREAS WITH PATIENT BED, 5'-6" (4'-0" + 1'-6")

STRETCHER OR GURNEY ACCESS, MINIMUM WIDTH,

BARIATRIC 6'-0"

• PATIENT CARE BUILDING ENTRY, EXIT, AND DEPARTMENT

ENTRY DOORS MINIMUM WIDTH. 4'-0"

WATER CLOSETS - INPATIENT NURSING UNITS

• GRAB BAR CONFIGURATION: DOUBLE SWING-UP BARS FOR

ALL PATIENT TOILETS/SHOWER ROOMS ON NURSING UNITS

W/ INTEGRAL TOILET PAPER DISPENSER.

• DISTANCE FROM TOILET CENTERLINE TO SIDE WALL 3'-0"

• DISTANCE FROM EDGE OF TOILET TO SIDE WALL, BARIATRIC 3'-0"

TOILET STALLS

• MINIMUM ACCESSIBLE STALL SIZE 5'-6" X 6'-0"

• MINIMUM SIZE WHEELCHAIR "FRONT-TRANSFER" STALL 3'-6" X 6'-0"

• GRAB BARS REQUIRED IN ALL STALLS

SHOWER STALLS (PATIENT)

• MINIMUM STALL DIMENSIONS 4'-0" X 4'-0"

• MINIMUM BARIATRIC STALL DIMENSIONS 4'-0" X 6'-0"

• GRAB BARS HORIZONTAL PLUS VERTICAL BARS

TOILET ROOMS

• INPATIENT BEDROOM TOILET ROOMS,

MINIMUM WIDTH OF TOILET ROOM ENTRANCE DOORS 48"

CAFETERIAS

• KNEE CLEARANCE, FOR MINIMUM 5% TABLES 2'-3" & 2'-5" FOR AT LEAST 5%

• CUTLERY AND SUPPLY HEIGHT 40" - 48"

HEALTH CARE FACILITIES

• MEDICAL/SURGICAL NURSING UNITS,

PERCENT OF PATIENT BEDROOMS ACCESSIBLE 100%

Figure 404.2.4.3 Maneuvering Clearance at Recessed Doors and Gates

Figure 404.2.4.2 Maneuvering Clearance at Sliding and Folding Doors

Figure 404.2.4.1 Maneuvering Clearance at Manual Swinging Doors and Gates

Figure 404.2.3 Clear Width of Doorways

Figure 404.2.6 Doors in Series and Gates in Series

(e) hinge approach, pull side

(j) latch approach, push side

(k) latch approach, push side

*48 min if door provided with closer

(i) latch approach, pull side

*54 min if door provided with closer

(h) latch approach, pull side

(f) hinge approach, push side

(g) hinge approach, push side

*if door provided with both closer and latch ** 48 min if both closer and latch provided

(b) front approach, push side

(c) front approach, push side

*if door provided with both closer and latch

(a) front approach, pull side

(a) hinged door

(b) sliding door

(c) folding door

(d) doorways without doors

(a) pull side

(b) push side

(c) push side, door provided with both closer and latch

(a) front approach

(b) side approach

*48 min at front approach

(c) pocket or hinge approach

(d) stop or latch approach

(d) hinge approach, pull side

(a)

(c)

(b)

(d) front approach symbol

90.

32" min

32" min

32" min

36" min

18" min m in m in

*12" min

36" min 60 m in

42" min m in

2" m in

22" min* 12" min m in

24" min

24" min m in m in m in

22" min m in m in

24" min m in

18" min

X >8

X >8 m in m in

12" min

X >8

48" min

48" min

48" min m in

66" min

D O

O R

S A

N D

G A

T E

S

Figure 407.2.2.2 Visible Hall Signals

Figure 407.2.3.1 Floor Designations on

Jambs of Elevator Hoistway Entrances

Figure 407.2.3.2 Car Designations on Jambs of Destination-Oriented Elevator

Hoistway Entrances

Figure 407.2.1.1 Height of Elevator Call Buttons

2" M in

2" M in

1/

2" M in

1/

2" M in

Figure 410.6 Platform Lift Doors and Gates platform lif t m ec h an is m

M in

36" Min

Figure 410.5.1.1 Platform Lifts-Size with single door or doors on opposite ends -new buildings

M in

36" Min

Figure 410.5.1.2 Platform Lifts-Size with single door or doors on opposite ends -existing buildings

M in

36" Min

Figure 410.5.2.2 Platform Lifts-Size with doors on adjacent sides existing building

M in

42" Min

Figure 410.5.2.1 Platform Lifts-Size with doors on adjacent sides new building

M in

32" Min

Figure 409.4.6.2 Location of Private Residence

Elevator Control Panels

M in

Figure 407.4.1 Elevator Car Door Sizes

(a) centered door

(b) side (off-centered) door

(c) any door location

(d) any door location

(e) Exception existing elevator car configuration

16 sq ft Min

M in

M in

54" Min 60" Min 36" Min

M in

80" Min 68" Min

42" Min

M in

M in

M in

M in

36" Min

36" Min

36" Min

Figure 408.4.1 Limited Use/Limited Application (LULA) Elevator Car and Door Sizes

(b) Exception 1

(c) Exception 2

(a) New Construction

15 sq ft Min

42" Min 51" Min 36" Min

32" Min 36" Min

M in

M in

M in

E L

E V

A T

O R

S

VA FORM 08 - 6231

A

B

C

D

A

B

C

D

2 4 5 61

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

STRUCTURAL:

ALBERTSON ENGINEERING, INC.

3202 W. MAIN ST., #C

RAPID CITY, SD 57702

605-343-9606

MEP:

WEST PLAINS ENGINEERING, INC.

1750 RAND ROAD

RAPID CITY, SD 57702

605-348-7455

STEPHEN KILBER MIKE SIGMAN (ELEC)

MICHAEL HEINRICH (MECH)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

D om R en ov

B ui ld in g

_k yl ek 9D

U H

U .rv t 6/

2/

:0 1:

P

M

GI012

ACCESSIBILITY DETAILS

STONE GROUP ARCHITECTS

600 EAST 7TH ST.

SIOUX FALLS, SD 57103

605-271-1144

TODD STONE

DOM RENOVATION FOR

SEMIPRIVATE ROOMS

HOT SPRINGS, SD

DOUG SPRINKLE

06/03/2025 JM/GB/TM TL/KK

SGA #211921

VA #568A4-21-208

BID DOCUMENTS

GENERAL ACCESSIBILITY NOTES

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER BEFORE

PROCEEDING WITH THE WORK.

B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

C. ALL CONSTRUCTION AND RENOVATION SHALL MEET THE ARCHITECTURAL BARRIERS ACT

ACCESSIBILITY STANDARD (ABAAS).

D. SUPPLEMENTAL TO THE (ABAAS), CONSTRUCTION & RENOVATION IN HEALTH FACILITIES OF THE

DEPARTMENT OF VETERAN AFFAIRS (VA) SHALL COMPLY WITH THE VA BARRIER FREE DESIGN

STANDARD: A SUPPLEMENT TO THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS

(PG-18-13).

VA BARRIER FREE DESIGN STANDARDS THAT ARE

MORE RESTRICTIVE THAN ABAAS & IBC REQUIREMENTS

MINIMUM REQUIREMENTS

• SITES - PARKING SPACES ACCESSIBLE 1% GREATER THAN ABAAS

• SPINAL CORD INJURY/DISORDER (SCI/D) FACILITIES: 0.2

ACCESSIBLE SPACES PER INPATIENT BED; 0.5 PER

LONG-TERM CARE BED; 5.6 PER OUTPATIENT EXAM ROOM.

DEDICATED FOR SCI/D PATIENTS

• HOSPITAL OUTPATIENT FACILITIES 10% OF TOTAL SPACES

• REHABILITATION AND OUTPATIENT

PHYSICAL THERAPY FACILITIES 20% OF TOTAL SPACES

• BUILDING-ACCESSIBLE SEATING, ASSEMBLY AREAS 1% GREATER THAN ABAAS

ACCESSIBLE ROUTE

• WIDTH, MIN. PATIENT CARE AREAS 6'-0"

• WIDTH, MIN. ADMINISTRATIVE AREA 5'-0"

• SLOPE, MAXIMUM (INCLUDING PARKING SPACES) 1:50 (2%)

• MINIMUM GRADIENT OF WALK REQUIRING REST

AREAS EVERY 200' 1:50 (2%)

• TURNING RADIUS 5'-6"

• TURNING RADIUS, BARIATRIC 6'-0"

• T-SHAPED TURNING SPACE 5'-6" x 5'-6"

• T-SHAPED TURNING SPACE, BARIATRIC 6'-0" x 6'-0"

FLOOR SURFACES

• CHANGES IN LEVEL NOT PERMITTED ON SCI/D FLOORS

• CARPET CUSHION OR PADDING NOT PERMITTED

PARKING & PASSENGER LOADING ZONES

• ACCESS AISLE REQUIREMENT FOR ACCESSIBLE

PARKING SPACES 5'-0" EACH SIDE

• PASSENGER LOADING AREA

"COMMUNICATION SYSTEM" FOR ASSISTANCE AT SCI UNITS YES

CURB RAMPS

• WIDTH, MINIMUM 4'-0"

RAMPS

• MAXIMUM SLOPE 1:20

• MAXIMUM LENGTH, WITHIN RANGE OF 1:33 - 1:26 40'

• MAXIMUM LENGTH, WITHIN RANGE OF 1:25 - 1:20 35'

• MINIMUM CLEAR WIDTH 4'-0"

• MINIMUM SIZE LEVEL LANDING, WHERE DOORS

SWING INTO LANDING 6'-0" X 6'-0"

STAIRS

• HANDRAIL HEIGHT 34"

ELEVATOR (PASSENGER)

• MINIMUM WIDTH OF ELEVATOR DOORS 4'-0"

• MINIMUM CAR SIZE 8'-0" X 6'-2" PLATFORM SIZE

• DOUBLE SET OF HANDRAILS YES

WINDOWS

• SILL HEIGHT IN PATIENT BEDROOMS 24" MAXIMUM

DOORS & DOORWAYS

• PATIENT CARE DELIVERY AREAS WITH PATIENT BED,

STRETCHER OR GURNEY ACCESS, MINIMUM WIDTH 5'-0" SLIDER TYPE

• PATIENT CARE DELIVERY AREAS WITH PATIENT BED, 5'-6" (4'-0" + 1'-6")

STRETCHER OR GURNEY ACCESS, MINIMUM WIDTH,

BARIATRIC 6'-0"

• PATIENT CARE BUILDING ENTRY, EXIT, AND DEPARTMENT

ENTRY DOORS MINIMUM WIDTH. 4'-0"

WATER CLOSETS - INPATIENT NURSING UNITS

• GRAB BAR CONFIGURATION: DOUBLE SWING-UP BARS FOR

ALL PATIENT TOILETS/SHOWER ROOMS ON NURSING UNITS

W/ INTEGRAL TOILET PAPER DISPENSER.

• DISTANCE FROM TOILET CENTERLINE TO SIDE WALL 3'-0"

• DISTANCE FROM EDGE OF TOILET TO SIDE WALL, BARIATRIC 3'-0"

TOILET STALLS

• MINIMUM ACCESSIBLE STALL SIZE 5'-6" X 6'-0"

• MINIMUM SIZE WHEELCHAIR "FRONT-TRANSFER" STALL 3'-6" X 6'-0"

• GRAB BARS REQUIRED IN ALL STALLS

SHOWER STALLS (PATIENT)

• MINIMUM STALL DIMENSIONS 4'-0" X 4'-0"

• MINIMUM BARIATRIC STALL DIMENSIONS 4'-0" X 6'-0"

• GRAB BARS HORIZONTAL PLUS VERTICAL BARS

TOILET ROOMS

• INPATIENT BEDROOM TOILET ROOMS,

MINIMUM WIDTH OF TOILET ROOM ENTRANCE DOORS 48"

CAFETERIAS

• KNEE CLEARANCE, FOR MINIMUM 5% TABLES 2'-3" & 2'-5" FOR AT LEAST 5%

• CUTLERY AND SUPPLY HEIGHT 40" - 48"

HEALTH CARE FACILITIES

• MEDICAL/SURGICAL NURSING UNITS,

PERCENT OF PATIENT BEDROOMS ACCESSIBLE 100%

Figure 703.6.1 Pictogram Field

MEN not in pictogram field

6" M in

Figure 705.1 Size and Spacing of Truncated Domes base diameter of 0.9"-1.4" top diameter of 50%-65% of the base diameter

(a) elevation (enlarged)

(b) plan

.6 5"

M in 1.6" - 2.4"

1.

6"

.4

Figure 707.6.2 Numeric Key Layout

(a) 12-key ascending

(b) 12-key descending

1 2 3

4 5 6

7 8 9

* 0 #

7 8 9

4 5 6

1 2 3

* 0 #

Figure 703.2.5 Height of Raised

Characters

LIBRARY

5/ 8"

"0.

2"

Figure 703.3.1 Braille Measurement single braille cell blank cell space between words raised dot no raised dot

Figure 703.3.2 Position of Braille

AREA OF

REFUGE

3/ 8" m in

3/ 8" m in

Figure 703.7.2.1 International Symbol of Accessibility

Figure 703.7.2.2 International TTY Symbol

Figure 703.7.2.3 Volume-Controlled Telephone

Figure 703.7.2.4 International Symbol of Access for

Hearing Loss

Figure 704.2.1.1 Parallel Approach to

Telephone

Figure 704.2.1.2 Forward Approach to

Telephone

Figure 703.4.1 Height of Tactile Characters

Above Floor or Ground

Figure 703.4.2 Location of Tactile Signs at Doors

AREA OF

REFUGE

centered on tactile characters

AREA OF

REFUGE

.00

M ax

M ax

M in

M ax

18" Min

M in d is ta n ce b et w ee n c o rr es p o n d in g d o ts fr o m o n e ce ll d ir ec tl y b el o w d is ta n ce b et w ee n d o ts in t h e sa m e ce ll distance between corresponding dots in adjacent cells distance between dots in the same cell b as e d ia m et er

C O

M M

U N

IC

A

T

IO

N E

L E

M E

N T

S A

N D

F E

A T

U R

E S

Figure 605.2 Height and Depth of Urinals

(a) wall hung type

Figure 604.2 Water Closet

Location

(a) wheelchair accessible water closets

(b) ambulatory accessible

Water closets

Figure 604.3.1 Size of Clearance at

Water Closets

Figure 604.3.2 (exception) Overlap of Water Closet Clearance in Residential

Dwelling Units

Figure 604.5.1 Side Wall Grab Bar at

Water Closets

Figure 604.5.2 Rear Wall Grab Bar at Water Closets

Figure 1104.11.1.1 Swing-up Grab Bar for Water Closet

Figure 604.7 Dispenser Outlet Location

Figure 604.8.1.2 Wheelchair Accessible Toilet

Compartment Doors

Figure 604.9.5 Wheelchair Accessible Toilet Compartment Toe Clearance

Figure 604.8.2 Ambulatory Accessible

Toilet Compartment

Transfer Side comply with section 609.3

(a) adult wall hung water closet

(b) adult floor mounted water closet and children's water closet

(a) elevation children

(b) plan alternate door location

Figure 604.9.2.3 Wheelchair Toilet Compartments Alternate

Wheelchair Toilet Compartment m in

60" min

Figure 604.8.1.1 Size of Wheelchair Accessible Toilet Compartments m in

60" min m in

60" min 42 m in

4" max

4" m ax m in m in

35" - 37"

8" m in

8" min m in8" min

Partition m in m ax7" - 9"

18" min 18" min

15 3/4" 15 3/4" 36" min

24" min min

12" 12" max 42" min

54" min

42" m in

39" - 41" m in m in

60" min

18" min m in

60" min

16" - 18"

17" - 19"

P L

U M

B

IN

G E

L E

M E

N T

S A

N D

F A

C

IL

IT

IE

S

T O

IL

E

T S

A N

D U

R

IN

A L

S m ax

13 1/2" min

(b) stall type

13 1/2" min

Figure 609.2.2 Grab Bar Non-Circular Cross Section

4" - 4.8" perimeter

2" m ax 2" max

(a) (b)

Figure 607.2 Clearance for Bathtubs

Figure 607.4.1 Grab Bars for Bathtubs with

Permanent Seats

Figure 607.4.2 Grab Bars for Bathtubs with Removable In-Tub Seats

Figure 607.5 Bathtub Control

Location

Figure 610.2 Bathtub Seats back wall head end wallcontrol end wall back wall head end wall control end wall

(b) plan back wall head end wall control end wall back wall head end wall control end wall

(a) removable in-tub seat

(b) permanent seat control end wall

(a) Removable In-Tub seat

(b) Permanent seat

(a) elevation

(b) plan

Length of Bathtub m in

Length of Bathtub 12" min m in

(a) elevation

8"

0"

15" max12" max m in

8"

0" m in

24" min

12" max 24" max m in

15" min15" - 16"

Figure 608.3.1 Grab Bars for Transfer-

Type Showers

Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers

Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers seat wall control wall back wall back wall side wall side wall back wall back wall front wall side wall side wall side wall side wall

(b) with seat

Figure 608.2.1.2(B) Transfer-Type Shower Compartment Clearances

New Buildings- Option 2 seat wall control wall back wall

52" max m ax

4" max

Figure 608.2.1.2(C) Transfer-Type Shower Compartment Clearances

Existing Buildings- Option 2 seat wall control wall back wall m ax

48" max

18"

4" M ax

6" m ax

6" m ax

6" max 6" max

6" max6" max

6" m ax

Figure 608.5.1 Transfer-Type Shower Compartment Control

Location

Figure 608.5.2 Standard Roll-In Type Shower Compartment

Control Location

Figure 608.5.3 Alternate Roll-In Type Shower Compartment Control Location

Figure 609.3 Spacing of Grab Bars side wall back wall can be located on any wall of shower

(a) without seat

(b) with seat

(a) projecting objects

(b) recessed objects side wall back wall

(a) with seat

(elevation)

(b) with seat

(elevation)

(d) with seat

(plan)

(c) without seat

(plan) side wall side wall side wall side wall back wallback wall front wall front wall

15" max m in m ax m in m ax m ax

Figure 610.3 Extent of Seat

Figure 610.3.1 Rectangular Shower Seat

Figure 610.3.2 L-Shaped Shower Seat seat…

This is the start of the file's text. The full file is on GovTribe.