512-23121.JLM Chesterfield - Sidock - MEP Drawings.pdf
PDF 5 MB Posted
- Solicitation number
- RFQ - 171 - 240000000127
- Issued by
- Macomb County, Chesaning Village, Michigan
About this file
This document contains electrical, mechanical, and plumbing drawings for a warehouse construction project at the Chesterfield Veterans Home, which is being conducted by the State of Michigan Department of Military and Veterans Affairs. The project includes the construction of an 8,000 square foot warehouse building, as well as associated electrical, mechanical, and plumbing work. The drawings provide details on the electrical power and lighting systems, HVAC equipment, and plumbing layouts for the new building. Key details include the installation of a new 200A electrical panel, overhead door power connections, lighting fixtures and controls, and HVAC units. The bid attachments must be uploaded to the SIGMA VSS system, and any questions should be emailed to the specified contact. Bidders may be required to submit proposals via email if they experience issues with the SIGMA VSS system.
The drawings do not provide any pricing information, set-aside requirements, or details on the incumbent contractor. The project is being funded by the State of Michigan, but the specific funding sources and amounts are not specified. The contract term and any renewal options are also not included in the documentation provided.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE:
N
ES-100
1 ELECTRICALN SITE PLAN
1" = 20'-0"
S
TA
TE
O
F M
IC
H
IG
A
N
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N D
E P
A R
TM
E
N T
O F
M
IL
IT
A
R Y
A N
D V
E
TE
R A
N S
A
FF
A
IR
S
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022
FOR SITE OWNED UTILITIES
E S
-1
E
LE
C
TR
IC
A
L S
IT
E
P
LA
N
GENERAL NOTES
A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
B. REFER TO ONE-LINE DIAGRAM AND PANEL SCHEDULES ON
DRAWING EP-600 FOR ADDITIONAL INFORMATION.
NOTES
1. FURNISH AND INSTALL (1) 2" SCH 40 PVC EMPTY CONDUIT
WITH PULLSTRING FROM ELECTRICAL ROOM IN EXISTING
FACILITY TO PROPOSED WAREHOUSE BUILDING. STUB-UP
CONDUIT IN PROPOSED WAREHOUSE BUILDING 6" ABOVE
FINISHED FLOOR AND CAP FOR FUTURE USE.
NEW PANEL PP-1
NOTE B
TO EXISTING PANEL S2B
IN EXISTING ELECTRICAL ROOM
NOTE B
2" C 3-1/C #4/0
1-1/1C #6 GND
NOTE 1
2" C SPARE
NOTE 1
PROPOSED
WAREHOUSE BUILDING
8,000 SF
/1
7/
KITCHENETTETOILET ROOM
TOILET ROOM
CONFERENCE ROOM
JANITOR'S CLOSET
OFFICE
102104
HALL
FOYER
J
WAREHOUSE
A B C D E F
D.1C.1
0.5
M J
J
J
S S
J
SM
S
TA
TE
O
F M
IC
H
IG
A
N
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N D
E P
A R
TM
E
N T
O F
M
IL
IT
A
R Y
A N
D V
E
TE
R A
N S
A
FF
A
IR
S
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022
FOR SITE OWNED UTILITIES
E P
-1
E
LE
C
TR
IC
A
L / P
O W
E R
C
O M
M U
N
IC
A
TI
O N
S F
LO
O
R P
LA
N
S
GENERAL NOTES
A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
B. DRAWINGS ARE DIAGRAMMATIC ONLY AND INDICATE
GENERAL ARRANGEMENT OF ELECTRICAL WORK.
LOCATIONS ARE APPROXIMATE AND SUBJECT TO MINOR
MODIFICATIONS AS DIRECTED BY OWNER/ENGINEER.
C. USE #12 CONDUCTORS FOR 20A CIRCUIT HOME RUNS IF
BRANCH CIRCUIT RUN IS LESS THAN 100 FEET FOR 120
VOLT. USE #10 CONDUCTORS FOR 20A CIRCUIT HOME
RUNS IF BRANCH CIRCUIT RUN EXCEEDS 100 FEET FOR 120
VOLT.
D. ALL POWER WIRING FOR MECHANICAL EQUIPMENT SHALL
BE FURNISHED AND INSTALLED BY ELECTRICAL
CONTRACTOR. MECHANICAL CONTRACTOR IS
RESPONSIBLE FOR ALL CONTROL AND INTERLOCKING
WIRING.
E. REFER TO ONE-LINE DIAGRAM ON DRAWING EP-600 FOR
ADDITIONAL INFORMATION.
F. REFER TO PANEL SCHEDULE ON DRAWING EP-600 FOR
ADDITIONAL INFORMATION.
NOTES
1. OVERHEAD DOOR BASIS OF DESIGN: 3HP MOTOR @ 208V, 3P.
OVERHEAD DOOR MOTOR SHALL INCLUDE CONTROLLER AND
CONTROL PUSH BUTTONS. CONTRACTOR SHALL FURNISH AND
INSTALL A 30A DISCONNECT SWITCH (FUSED OR NON-FUSED
PER OVERHEAD DOOR MANUFACTURER REQUIREMENTS)
ADJACENT TO OVERHEAD DOOR CONTROLLER. FURNISH AND
INSTALL CONDUIT AND WIRING TO LINE SIDE OF OVERHEAD
DOOR CONTROLLER. COORDINATE ALL WORK WITH OVERHEAD
DOOR CONTROLLER. COORDINATE ALL WORK WIT OVERHEAD
DOOR INSTALLER.
2. TYPICAL VOICE/DATA OUTLETS SHALL BE 4" X 4" X 2 3/4" WITH
SINGLE GANG MUD RINGS AND 1" CONDUIT WITH PULLSTRING
TO OPEN SPACE ABOVE NEAREST CEILING (NORMALLY IN THE
SAME ROOM). VOICE/DATA CABLING AND TERMINATIONS SHALL
BE FURNISHED AND INSTALLED BY OWNER'S IT CONTRACTOR.
3. REFER TO ELECTRICAL SITE PLAN ON DRAWING ES-100 AND
ELECTRICAL ONE-LINE DIAGRAM ON DRAWING EP-600 FOR
ADDITIONAL INFORMATION.
4. PER NEC 408.4, PANELBOARD SHALL HAVE LABEL
PERMANENTLY AFFIXED INDICATING SOURCE OF SUPPLY
POWER IS LOCATED IN A DIFFERENT BUILDING/FACILITY.
5. FURNISH AND INSTALL 1 1/4" EMPTY CONDUIT WITH PULL
STRING FROM JUNCTION BOX IN WALL TO IN-FLOOR JUNCTION
BOX FOR HDMI CABLE. HDMI CABLE TO BE FURNISHED AND
INSTALLED BY OTHERS.
6. FURNISH AND INSTALL A 60A, 3P NON-FUSED NEMA 1
DISCONNECT SWITCH, SQUARE D MODEL HU362 OR
EQUIVALENT.
7. FURNISH AND INSTALL A 30A, 3P NON-FUSED NEMA 1
DISCONNECT SWITCH, SQUARE D MODEL HU361 OR
EQUIVALENT.
8. MOTOR OPERATE TOGGLE DISCONNECT SWITCH SUPPLIED
WITH UNIT.
9. REFER TO WIRING DIAGRAM ON EP-500 FOR ADDITIONAL
INFORMATION.
10. DISCONNECT SWITCH SUPPLIED WITH UNIT.
SCALE:
N
EP-110
1 FLOOR PLAN - POWER
1/8" = 1'-0"
SCALE:
N
EP-110
2 ENLARGED OFFICE SUITE - POWER
3/16" = 1'-0"
SCALE:
N
EP-110
4 ENLARGED TOILET ROOMS - POWER
1/4" = 1'-0"
EP-110
SCALE:
N
EP-110
3 ENLARGED KITCHEN - POWER
1/4" = 1'-0"
EP-110
EP-110
MICROWAVE
PP-1-15
PP-1-19
PP-1-17
PP-1-19PP-1-17
PP-1-17
REFRIGERATOR
PP-1-13
PP-1-21
PP-1-21
PP-1-22
PP-1-22
PP-1-24
PP-1-24
PP-1-22
PP-1-22
PP-1-21
PP-1-21
PP-1-18
PP-1-20
PP-1-20
PP-1-20
PP-1-20
+48"
PP-1-18
+48"
PP-1-18
+48"
PP-1-8
+48"
PP-1-10
+48"
PP-1-10
+48"
PP-1-10
+48"
PP-1-12
+48"
PP-1-12
+48"
PP-1-12
WP
PP-1-16
WP
PP-1-16
+48"
PP-1-14
PP-1-14
+48"
+48"
PP-1-8+48"
PP-1-8
PP-1-2,4,6
PANEL PP-1
NOTE 4
3/4" C 3-1/C #10
1-1/C #10 GND
OVERHEAD
DOOR
NOTE 1
TO EXISTING
PANEL S2B
NOTE 3
2-2" C
NOTE 3
WP
PP-1-8
SYMBOLS
20A DUPLEX RECEPTACLE
20A GFCI DUPLEX RECEPTACLE
20A GFCI DUPLEX RECEPTACLE - ABOVE COUNTER
DISCONNECT SWITCH
VOICE / DATA OUTLET
20A FLUSH FLOOR DUPLEX RECEPTACLE
WITH VOICE/DATA OUTLETS
20A QUAD RECEPTACLE
20A DUPLEX RECEPTACLE - ABOVE COUNTER
JUNCTION BOXJ
3/4" C 2-1/C #10
1 1/C #10 GND
IWH-2
PP-1-40
IWH-2
IWH-1
IWH-1
PP-1-38
3/4" C 2-1/C #10
1 1/C #10 GND
R-2
TO EF-1
TO EF-1
R-1
PP-1-34
PP-1-36
3/4" C 2-1/C #8 1 1/C #10
3/4" C 2-1/C #8 1 1/C #10
PP-1-26PP-1-26
PP-1-25
TV
PP-1-27
+60" +60"
+60"
NOTE 5
EP-110
3/4" C 3-1/C #8
1-1/C #10 GND
PP-1-47,49,51
EUH-1
NOTE 6
3/4" C 3-1/C #8
1-1/C #10 GND
PP-1-44,46,48
EUH-1
NOTE 6
3/4" C 3-1/C #8
1-1/C #10 GND
PP-1-50,52,54
EUH-1
NOTE 6
SCALE:
N
EP-110
5 EQUIPMENT DECK PLAN - POWER
1/8" = 1'-0"
EC.2
AHU-1
NOTE 7
NOTE 6
PP-1-28,30
PP-1-37,39
3/4" C 2-1/C #10
1 1/C #10 GND
1" C 2-1/C #6
1 1/C #10 GND
ELEC. HEAT
FOR AHU
NOTE 6EF-1
NOTE 9
NOTE 8
3/4" C 2-1/C #10
1 1/C #10 GND
PP-1-32
PP-1-33,35
3/4" C 2-1/C #8
1 1/C #10 GND
+48"
+48"
PP-1-10
PP-1-29
PP-1-31
+48"
TOILET ROOM
TOILET ROOM
KITCHENETTE
PP-1-43,453/4" C
2-1/C #10
1-1/C #10 GND
EWH-1
NOTE 10
PP-1-21
WP
/1
7/
S
TA
TE
O
F M
IC
H
IG
A
N
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N D
E P
A R
TM
E
N T
O F
M
IL
IT
A
R Y
A N
D V
E
TE
R A
N S
A
FF
A
IR
S
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022
FOR SITE OWNED UTILITIES
E P
-5
E
LE
C
TR
IC
A
L D
E
TA
IL
S
GENERAL NOTES
A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
NOTES
1. FURNISH AND INSTALL RELAY WITH 120V COILS AND
NORMALLY OPEN (NO) CONTACTS RATED FOR AT
LEAST 5 AMPS AT 120 VAC, INDUCTIVE DUTY.
EXHAUST FAN EF-1 WIRING DIAGRAM
PP-1-5
H N
L LIGHT
TOILET RM
104 SWITCH
C
RELAY R1
NOTE 1
H
PP-1-32
PP-1-5
H N
L LIGHT
TOILET RM
105 SWITCH
C
RELAY R2
NOTE 1
H
PP-1-32
N
EF-1
/1
7/
TE
O
F M
IC
H
IG
A
N
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N D
E P
A R
TM
E
N T
O F
M
IL
IT
A
R Y
A N
D V
E
TE
R A
N S
A
FF
A
IR
S
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022
FOR SITE OWNED UTILITIES
E P
-6
E
LE
C
TR
IC
A
L O
N E
-L
IN
E D
IA
G
R A
M
P A
N E
L S
C H
E D
U
LE
S
GENERAL NOTES
A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
NOTES
1. FURNISH AND INSTALL A 200 MCB, 208/120V, 3PH, 4W
PANELBOARD, SQUARE D INTERIOR NQ442L2C WITH BOX
(NEMA 1) CAT #MH50 AND NC50S FRONT AND NQN2CU
NEUTRAL BAR OR EQUIVALENT.
2. FURNISH AND INSTALL A 200A/200AT CIRCUIT BREAKER, GE
MODEL SFHA36AT0200 OR EQUIVALENT.
1-2" C 3-1/C #4/0
1-1/C #6 GND
1-2" C SPARE
EXISTING
PANEL
R2BA
TO EXISTING PANEL D2B
EXISTING
SMOKE
SHACK
60A
EXISTING
SURGE
DEVICE
30A 20A
NEW PANEL
PP-1
NOTE 1
200AF
200AT
NOTE 2
SPARESPARE
EXISTING PANEL S2B: XXXA, 208/120V, 3P, 4W
#4 GND
PARTIAL ONE-LINE DIAGRAM
/1
7/
A B C D E F
D.1C.1
0.5
SLD1SLD1
SL
D1
SL
D1
SL
D1
SL
D1
TOILET ROOM
TOILET ROOM
CONFERENCE ROOM
JANITOR'S CLOSET
OFFICE
HALL
FOYER
OS1
SLD
SLD2
OS2
S L D1
OS1
OS1
SO
S
OS2
SO
S
KITCHENETTE
S L D2
S O
S S
O S
OS1
SLD1
S
TA
TE
O
F M
IC
H
IG
A
N
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N D
E P
A R
TM
E
N T
O F
M
IL
IT
A
R Y
A N
D V
E
TE
R A
N S
A
FF
A
IR
S
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022
FOR SITE OWNED UTILITIES
SCALE:
N
EL-110
1 FLOOR PLAN - LIGHTING
1/8" = 1'-0"
SCALE:
N
EL-110
2 ENLARGED OFFICE SUITE - LIGHTING
3/16" = 1'-0"
SCALE:
N
EL-110
4 ENLARGED TOILET ROOMS - LIGHTING
1/4" = 1'-0"
EL-110
SCALE:
N
EL-110
3 ENLARGED KITCHEN - LIGHTING
1/4" = 1'-0"
E L-
E
LE
C
TR
IC
A
L
LI
G H
TI
N
G F
LO
O
R P
LA
N
EL-110
EL-110
GENERAL NOTES
A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
B. DRAWINGS ARE DIAGRAMMATIC ONLY AND INDICATE
GENERAL ARRANGEMENT OF ELECTRICAL WORK.
LOCATIONS ARE APPROXIMATE AND SUBJECT TO MINOR
MODIFICATIONS BY THE OWNER/ENGINEER.
C. COORDINATE EXACT LOCATION OF DEVICES WITH OTHER
TRADES FOR AVOIDANCE OF ANY OBSTRUCTIONS. VERIFY
WALL SWITCHING OF ELECTRICAL LIGHTING PLANS FOR
PROPER TYPES OF OPTIONS REQUIRED ON ALL FIXTURES.
VERIFY CEILING TYPES ON ARCHITECTURAL REFLECTED
CEILING PLANS FOR PROPER INSTALLATIONS OF TRIMS
AND FOR EXACT MOUNTING LOCATIONS ON ALL FIXTURES.
D. USE #12 CONDUCTORS FOR 20A CIRCUIT HOME RUNS IF
BRANCH CIRCUIT RUN IS LESS THAN 100 FEET FOR 120
VOLT. USE #10 CONDUCTORS IF BRANCH CIRCUIT RUN
EXCEEDS 100 FEET FOR 120 VOLT.
E. LIGHTING CONTROL SYSTEM MANUFACTURER IS BASIS OF
DESIGN. ALTERNATE MANUFACTURER AND EQUIPMENT
LISTED THAT MEETS THE SALIENT CHARACTERISTICS OF
THE LIGHTING CONTROL DEVICES LISTED ARE
ACCEPTABLE. THE ENGINEER RESERVES THE RIGHT FOR
THE MANUFACTURER OR MANUFACTURERS
REPRESENTATIVE TO PROVIDE PROOF THAT THE
SELECTED EQUIPMENT MEETS ALL FUNCTIONS, PLANS,
AND SPECIFICATIONS ARE MET OR EXCEEDED. ALL "OR
EQUALS" ARE SUBJECT TO APPROVAL BY
ARCHITECT-ENGINEER.
F. LIGHTING CONTROL AND SENSORS SHOWN ON DRAWINGS
ARE INDICATED TO DEMONSTRATE DESIGN INTENT.
ACTUAL NUMBERS AND LOCATIONS OF DEVICES SHALL BE
AS RECOMMENDED BY THE LIGHTING CONTROL
MANUFACTURER/SUPPLIER. CONTRACTOR SHALL FURNISH
AND INSTALL POWER PACKS, AUXILIARY RELAYS, LOW
VOLTAGE TRANSFORMERS, TRANSFORMER DEVICES, ETC.
AS REQUIRED AND RECOMMENDED BY THE LIGHTING
CONTROL SYSTEM MANUFACTURER/SUPPLIER.
G. LETTER NEXT TO LIGHTING FIXTURE INDICATE FIXTURE
TYPE. REFER TO FIXTURE SCHEDULE ON DRAWING EL-600
FOR ADDITIONAL INFORMATION.
H. REFER TO PANEL SCHEDULE ON DRAWING EP-600 FOR
ADDITIONAL INFORMATION.
I. EMERGENCY AND EXIT LIGHTING FIXTURES TO BE
INSTALLED UNDER THIS CONTRACT SHALL BE FED FROM
THE SAME CIRCUIT AS NORMAL LIGHTING IN SPACE AND
SHALL BE CONNECTED AHEAD OF THE SWITCH.
NOTES
1. FURNISH AND INSTALL WALL MOUNTED OCCUPANCY SENSOR,
SENSOR SWITCH MODEL WSX PDT WH OR EQUIVALENT BY
WATTSTOPPER OR LEVITON.
2. FURNISH AND INSTALL WALL MOUNTED ON/OFF SWITCH WITH
DIMMING, NLIGHT MODEL NPODM DX WH OR EQUIVALENT BY
WATTSTOPPER OR LEVITON.
3. FURNISH AND INSTALL CEILING MOUNTED OCCUPANCY
SENSOR, NLIGHT MODEL NCM PDT 10 AR RJB OR EQUIVALENT
BY WATTSTOPPER OR LEVITON.
4. FURNISH AND INSTALL WALL MOUNTED ON/OFF SWITCH,
NPODM WH OR EQUIVALENT BY WATTSTOPPER OR LEVITON.
5. FURNISH AND INSTALL CEILING MOUNTED OCCUPANCY
SENSOR, SENSOR SWITCH MODEL CM PDT 10 OR EQUIVALENT
BY WATTSTOPPER OR LEVITON
SYMBOLS
WALL MOUNTED OCCUPANCY SENSOR - SEE NOTE 1
WALL MOUNTED ON/OFF SWITCH WITH DIMMING - SEE NOTE 2
CEILING MOUNTED OCCUPANCY SENSOR - SEE NOTE 3
WALL MOUNTED ON/OFF SWITCH - SEE NOTE 4
CEILING MOUNTED OCCUPANCY SENSOR - SEE NOTE 5
SOS
SLD1
SLD2
OS1
OS2
AA
A
A
Y
Y
Y
PP-1-5
PP-1-5
PP-1-7
AA
A A
AA
A A
A
A
A
A
A
X
X
PP-1-9
PP-1-7
Y
Y
PP-1-5
A
A
A
Y
Y PP-1-5
B B
BB
B B
B B
B
BBB
BB
Y
Y
C
PP-1-11 PP-1-9
A A
Y
Y
Y
Y
Y
X Y
PP-1-1
PP-1-3
PP-1-23
CX
PP-1-23
C
X
PP-1-23
C
PP-1-23
C
C
PP-1-11
D
PP-1-11
Y
Y
TOILET ROOM
TOILET ROOM
KITCHENETTE
BB
/1
7/
TE
O
F M
IC
H
IG
A
N
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N D
E P
A R
TM
E
N T
O F
M
IL
IT
A
R Y
A N
D V
E
TE
R A
N S
A
FF
A
IR
S
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022
FOR SITE OWNED UTILITIES
E L-
E
LE
C
TR
IC
A
L
LI
G H
TI
N
G F
IX
TU
R E
S C
H E
D U
LE
FIXTURE SCHEDULE
TYPE SIZE AND
MOUNTING
VOLTAGE,
(INPUT WATTAGE)
LAMPS AND
LUMENS
MANUFACTURER /
CATALOG NUMBER REMARKSSYMBOL
GENERAL NOTES
A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
B. LIGHTING FIXTURE MANUFACTURER AND MODE/SERIES NUMBER
LISTED IN SCHEDULE ARE BASIS OF DESIGN. ALTERNATE
MANUFACTURER AND EQUIPMENT THAT MEETS THE SALIENT
CHARACTERISTICS OF THE LIGHTING FIXTURES LISTED ARE
ACCEPTABLE. THE ENGINEER RESERVES THE RIGHTS FOR THE
MANUFACTURER OR MANUFACTURER'S REPRESENTATIVE TO
PROVIDE PROOF THAT SELECTED EQUIPMENT MEETS ALL
FUNCTIONS, PLANS, AND SPECIFICATIONS ARE MET OR
EXCEEDED. ALL "OR EQUALS" ARE SUBJECT TO APPROVAL BY
ARCHITECT-ENGINEER.
LIGHTING CONTROL SEQUENCE OF
OPERATION
LIGHTING CONTROL SYSTEM HAS BEEN DESIGNED TO MEET SPECIFIC
OPERATIONAL REQUIREMENTS AND FUNCTIONALITY AS FOLLOWS:
1. JC 101, TOILET ROOM 104, TOILET ROOM 105, FOYER 106
a. CONTROLLED BY: LOCAL WALL MOUNTED OCCUPANCY SENSOR
WITH DIMMING CONTROL NEAR DOOR OF EACH ROOM.
b. CIRCUIT CAPABILITY: SINGLE.
c. TIME DELAY: SET FOR 10-MINUTE DELAY.
d. SYSTEM BRANCH: NORMAL.
e. AUTOMATIC SWITCHING MODE: AUTOMATIC ON; MANUAL OR
AUTOMATIC OFF.
2. HALL 107
a. CONTROLLED BY: LOCAL CEILING MOUNTED OCCUPANCY
SENSOR(S) WITH LOCAL WALL MOUNTED ON/OFF WALLPODS AT
MAIN ACCESS DOOR(S) FOR MANUAL OVERRIDE OF AUTOMATIC
CONTROL.
b. CIRCUIT CAPABILITY: SINGLE.
c. TIME DELAY: SET FOR 10-MINUTE DELAY.
d. SYSTEM BRANCH: NORMAL.
e. AUTOMATIC SWITCHING MODE: AUTOMATIC ON; MANUAL OR
AUTOMATIC OFF.
3. OFFICE 100, KITCHENETTE 102, CONFERENCE ROOM 103
a. CONTROLLED BY: LOCAL CEILING MOUNTED OCCUPANCY
SENSOR(S) WITH LOCAL WALL MOUNTED ON/OFF DIMMER
SWITCHES AT MAIN ACCESS DOOR(S) OR ENTRANCE FOR
MANUAL OVERRIDE OF AUTOMATIC CONTROL.
b. CIRCUIT CAPABILITY: SINGLE.
c. TIME DELAY: SET FOR 10-MINUTE DELAY.
d. SYSTEM BRANCH: NORMAL.
e. AUTOMATIC SWITCHING MODE: MANUAL ON; MANUAL OR
AUTOMATIC OFF.
4. WAREHOUSE
a. CONTROLLED BY: INTEGRAL FIXTURE MOUNTED OCCUPANCY
SENSORS SHALL ILLUMINATE ALL FIXTURES TO 100% UPON
ENTRY OF PERSONNEL AT ANY ENTRY POINT. ALL FIXTURES
SHALL REDUCE TO 30% AFTER OCCUPANCY SENSORS DO NOT
DETECT ACTIVITY IN A LIGHTING ZONE FOR 20 MINUTES AND
SHALL SHUT OFF COMPLETELY AFTER 30 MINUTES OF NO
DETECTION. LOCAL WALLPODS AT MAIN ACCESS DOORS SHALL
BE PROVIDED FOR MANUAL OVERRIDE OF AUTOMATIC CONTROL.
b. CIRCUIT CAPABILITY: SINGLE.
c. TIME DELAY: 30% AT 20 MINUTES, OFF AT 30 MINUTES.
d. SYSTEM BRANCH: NORMAL.
e. AUTOMATIC SWITCHING MODE: AUTOMATIC ON; MANUAL OR
AUTOMATIC OFF.
NOTES
1. MOUNT BOTTOM OF FIXTURE AT 14'-0" ABOVE FINISHED FLOOR.
2. MOUNT BOTTOM OF FIXTURE 2" ABOVE DOOR FRAME.
3. MOUNT BOTTOM OF FIXTURE 16'-0" ABOVE FINISHED FLOOR.
4. MOUNT BOTTOM OF FIXTURE 8'-0" ABOVE FINISHED FLOOR.
5. FIXTURE SHALL MEET NFPA LIFE SAFETY CODE 101 AND BE
LISTED UNDER UL924.
6. FOR FIXTURES WITH HALF-SHADING ON FLOOR PLAN, FURNISH
AND INSTALL FIXTURE WITH EL14L BATTERY PACK.
A 2' X 4'
(NOMINAL)
TROFFER
120V (25W)
4000K
WHITE LIGHT
EMITTING
DIODES
3,097 LUMENS
(NOMINAL)
LITHONIA "TL LED" SERIES
2TL4 30L FW A12 GZ10 LP840
13"
(NOMINAL)
HIGH BAY
FIXTURE
120V (95W)
4000K
WHITE LIGHT
EMITTING
DIODES
13,630 LUMENS
(NOMINAL)
LITHONIA "JEBL" SERIES
JEBL 12000LM GL MVOLT
40K 80CRI WBF SBOR10
DWHXD
MANDOOR
FIXTURE
120V (17W)
4000K
WHITE LIGHT
EMITTING
DIODES
2,151 LUMENS
(NOMINAL)
LITHONIA "ARC1LED" SERIES
ARC1 LED P2 40K MVOLT E4WH
PE DDBXD
B
C
OVERHEAD
DOOR
FIXTURE
D
120V (51W)
4000K
WHITE LIGHT
EMITTING
DIODES
6,615 LUMENS
(NOMINAL)
LITHONIA "ARC 2 LED" SERIES
ARC2 LED P5 40K MVOLT PE
DDBXD
X
Y
EXIT
LIGHT
CEILING OR WALL
MOUNT
SURFACE
MOUNTED
EMERGENCY
FIXTURE
120V (4.3W)
120V (4.77)
RED LIGHT
EMITTING
DIODES
2-LED
FLOOD
LAMPS
LITHONIA "LQHM" SERIES
LHQM LED HORO
LITHONIA "ELM6L" SERIES
ELM6L UVOLT LTP SDRT HO
SEE NOTE 1
SEE NOTE 2
SEE NOTE 3
SEE NOTE 4, 5
SEE NOTE 4, 5
SEE NOTE 6
/1
7/
D.1C.1
0.5
0.5
SCALE:
N
M-110
1 FLOOR PLAN - HVAC
1/8" = 1'-0" SCALE:
N
M-110
2 ENLARGED OFFICE SUITE - HVAC
1/4" = 1'-0"
M-110
C.1 D.1
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
D
EP
AR
TM
EN
T
O F
M
IL
IT
AR
Y
AN
D V
ET
ER
AN
S
AF
FA
IR
S
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022
FOR SITE OWNED UTILITIES
M -1
H
VA
C F
LO
O
R P
LA
N
S
EC.2
WAREHOUSE
J.C.
OFFICE
TLT.
TLT.
CONFERENCE
FOYER
KITCHENETTE
HALL
SCALE:
N EQUIPMENT DECK PLAN - HVAC
1/8" = 1'-0"
EC.2
AutoCAD SHX Text
TUEBOR
AutoCAD SHX Text U
AutoCAD SHX Text S
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text
KAB
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text U
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
FINAL RECORD
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ISSUED FOR
AutoCAD SHX Text
FILE NO./INDEX CODE:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
IDENTIFICATION NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
AutoCAD SHX Text
FACILITIES AND BUSINESS SERVICES ADMINISTRATION
AutoCAD SHX Text
ADAM P. LACH,RA, DIRECTOR
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
UTILITIES
AutoCAD SHX Text 989-344-6184
AutoCAD SHX Text
72 HOURS
AutoCAD SHX Text
(3 WORKING DAYS)
AutoCAD SHX Text
CALL MR. HALCOMB
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text C.G.
AutoCAD SHX Text
FACILITIES MANAGEMENT
AutoCAD SHX Text
CAMP GRAYLING ENGINEERING
kgilson Cyril Seal
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
D
EP
AR
TM
EN
T
O F
M
IL
IT
AR
Y
AN
D V
ET
ER
AN
S
AF
FA
IR
S
C
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022
FOR SITE OWNED UTILITIES
M -9
H
VA
C S
C H
ED
U
LE
S
/0 3/
C M
KW
G
C M
R M R
/1 7/
AutoCAD SHX Text
TUEBOR
AutoCAD SHX Text U
AutoCAD SHX Text S
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text
KAB
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text U
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
FINAL RECORD
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ISSUED FOR
AutoCAD SHX Text
FILE NO./INDEX CODE:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
IDENTIFICATION NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
AutoCAD SHX Text
FACILITIES AND BUSINESS SERVICES ADMINISTRATION
AutoCAD SHX Text
ADAM P. LACH,RA, DIRECTOR
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
UTILITIES
AutoCAD SHX Text 989-344-6184
AutoCAD SHX Text
72 HOURS
AutoCAD SHX Text
(3 WORKING DAYS)
AutoCAD SHX Text
CALL MR. HALCOMB
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text C.G.
AutoCAD SHX Text
FACILITIES MANAGEMENT
AutoCAD SHX Text
CAMP GRAYLING ENGINEERING
D.1C.1
0.5
M
0.5
M
SCALE:
N
P-110
1 FLOOR PLAN - PLUMBING & PIPING
1/8" = 1'-0" SCALE:
N
P-110
2 ENLARGED OFFICE SUITE - PLUMBING & PIPING
3/16" = 1'-0"
P-110
ST
AT
E O
F M
IC
H
IG
AN
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
D
EP
AR
TM
EN
T
O F
M
IL
IT
AR
Y
AN
D V
ET
ER
AN
S
AF
FA
IR
S
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF
SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,
COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR
WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022
FOR SITE OWNED UTILITIES
P-
PL
U
M
BI
N G
P
IP
IN
G F
LO
O
R P
LA
N
S
EC.2
WAREHOUSE
J.C.
OFFICE
TLT.
TLT.
CONFERENCE
FOYER
KITCHENETTE
SCALE:
N
EQUIPMENT DECK PLAN - HVAC
1/8" = 1'-0"
EC.2
5'-0"
AutoCAD SHX Text
TUEBOR
AutoCAD SHX Text U
AutoCAD SHX Text S
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text
KAB
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text U
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
FINAL RECORD
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ISSUED FOR
AutoCAD SHX Text
FILE NO./INDEX CODE:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
IDENTIFICATION NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
AutoCAD SHX Text
FACILITIES AND BUSINESS SERVICES ADMINISTRATION
AutoCAD SHX Text
ADAM P. LACH,RA, DIRECTOR
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
UTILITIES
AutoCAD SHX Text 989-344-6184
AutoCAD SHX Text
72 HOURS
AutoCAD SHX Text
(3 WORKING DAYS)
AutoCAD SHX Text
CALL MR. HALCOMB
AutoCAD SHX Text
BEFORE YOU DIG
AutoCAD SHX Text C.G.
AutoCAD SHX Text
FACILITIES MANAGEMENT
AutoCAD SHX Text
CAMP GRAYLING ENGINEERING
| 512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 21 |
| 512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 22 |
| 512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 23 |
| 512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 24 |
| 512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 25 |
| 512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 26 |
| 512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 27 |
| 512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 28 |
| 512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 29 |
File details come from the government source that posted it. Updated .