512-23121.JLM Chesterfield - Sidock - MEP Drawings.pdf

PDF 5 MB Posted

Attached to
512/23121. JLM; Chesterfield Vet. Home - Maint. Bldg. & Whs.
Solicitation number
RFQ - 171 - 240000000127
Issued by
Macomb County, Chesaning Village, Michigan

About this file

This document contains electrical, mechanical, and plumbing drawings for a warehouse construction project at the Chesterfield Veterans Home, which is being conducted by the State of Michigan Department of Military and Veterans Affairs. The project includes the construction of an 8,000 square foot warehouse building, as well as associated electrical, mechanical, and plumbing work. The drawings provide details on the electrical power and lighting systems, HVAC equipment, and plumbing layouts for the new building. Key details include the installation of a new 200A electrical panel, overhead door power connections, lighting fixtures and controls, and HVAC units. The bid attachments must be uploaded to the SIGMA VSS system, and any questions should be emailed to the specified contact. Bidders may be required to submit proposals via email if they experience issues with the SIGMA VSS system.

The drawings do not provide any pricing information, set-aside requirements, or details on the incumbent contractor. The project is being funded by the State of Michigan, but the specific funding sources and amounts are not specified. The contract term and any renewal options are also not included in the documentation provided.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE:

N

ES-100

1 ELECTRICALN SITE PLAN

1" = 20'-0"

S

TA

TE

O

F M

IC

H

IG

A

N

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N D

E P

A R

TM

E

N T

O F

M

IL

IT

A

R Y

A N

D V

E

TE

R A

N S

A

FF

A

IR

S

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,

COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR

WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022

FOR SITE OWNED UTILITIES

E S

-1

E

LE

C

TR

IC

A

L S

IT

E

P

LA

N

GENERAL NOTES

A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

B. REFER TO ONE-LINE DIAGRAM AND PANEL SCHEDULES ON

DRAWING EP-600 FOR ADDITIONAL INFORMATION.

NOTES

1. FURNISH AND INSTALL (1) 2" SCH 40 PVC EMPTY CONDUIT

WITH PULLSTRING FROM ELECTRICAL ROOM IN EXISTING

FACILITY TO PROPOSED WAREHOUSE BUILDING. STUB-UP

CONDUIT IN PROPOSED WAREHOUSE BUILDING 6" ABOVE

FINISHED FLOOR AND CAP FOR FUTURE USE.

NEW PANEL PP-1

NOTE B

TO EXISTING PANEL S2B

IN EXISTING ELECTRICAL ROOM

NOTE B

2" C 3-1/C #4/0

1-1/1C #6 GND

NOTE 1

2" C SPARE

NOTE 1

PROPOSED

WAREHOUSE BUILDING

8,000 SF

/1

7/

KITCHENETTETOILET ROOM

TOILET ROOM

CONFERENCE ROOM

JANITOR'S CLOSET

OFFICE

102104

HALL

FOYER

J

WAREHOUSE

A B C D E F

D.1C.1

0.5

M J

J

J

S S

J

SM

S

TA

TE

O

F M

IC

H

IG

A

N

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N D

E P

A R

TM

E

N T

O F

M

IL

IT

A

R Y

A N

D V

E

TE

R A

N S

A

FF

A

IR

S

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,

COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR

WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022

FOR SITE OWNED UTILITIES

E P

-1

E

LE

C

TR

IC

A

L / P

O W

E R

C

O M

M U

N

IC

A

TI

O N

S F

LO

O

R P

LA

N

S

GENERAL NOTES

A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

B. DRAWINGS ARE DIAGRAMMATIC ONLY AND INDICATE

GENERAL ARRANGEMENT OF ELECTRICAL WORK.

LOCATIONS ARE APPROXIMATE AND SUBJECT TO MINOR

MODIFICATIONS AS DIRECTED BY OWNER/ENGINEER.

C. USE #12 CONDUCTORS FOR 20A CIRCUIT HOME RUNS IF

BRANCH CIRCUIT RUN IS LESS THAN 100 FEET FOR 120

VOLT. USE #10 CONDUCTORS FOR 20A CIRCUIT HOME

RUNS IF BRANCH CIRCUIT RUN EXCEEDS 100 FEET FOR 120

VOLT.

D. ALL POWER WIRING FOR MECHANICAL EQUIPMENT SHALL

BE FURNISHED AND INSTALLED BY ELECTRICAL

CONTRACTOR. MECHANICAL CONTRACTOR IS

RESPONSIBLE FOR ALL CONTROL AND INTERLOCKING

WIRING.

E. REFER TO ONE-LINE DIAGRAM ON DRAWING EP-600 FOR

ADDITIONAL INFORMATION.

F. REFER TO PANEL SCHEDULE ON DRAWING EP-600 FOR

ADDITIONAL INFORMATION.

NOTES

1. OVERHEAD DOOR BASIS OF DESIGN: 3HP MOTOR @ 208V, 3P.

OVERHEAD DOOR MOTOR SHALL INCLUDE CONTROLLER AND

CONTROL PUSH BUTTONS. CONTRACTOR SHALL FURNISH AND

INSTALL A 30A DISCONNECT SWITCH (FUSED OR NON-FUSED

PER OVERHEAD DOOR MANUFACTURER REQUIREMENTS)

ADJACENT TO OVERHEAD DOOR CONTROLLER. FURNISH AND

INSTALL CONDUIT AND WIRING TO LINE SIDE OF OVERHEAD

DOOR CONTROLLER. COORDINATE ALL WORK WITH OVERHEAD

DOOR CONTROLLER. COORDINATE ALL WORK WIT OVERHEAD

DOOR INSTALLER.

2. TYPICAL VOICE/DATA OUTLETS SHALL BE 4" X 4" X 2 3/4" WITH

SINGLE GANG MUD RINGS AND 1" CONDUIT WITH PULLSTRING

TO OPEN SPACE ABOVE NEAREST CEILING (NORMALLY IN THE

SAME ROOM). VOICE/DATA CABLING AND TERMINATIONS SHALL

BE FURNISHED AND INSTALLED BY OWNER'S IT CONTRACTOR.

3. REFER TO ELECTRICAL SITE PLAN ON DRAWING ES-100 AND

ELECTRICAL ONE-LINE DIAGRAM ON DRAWING EP-600 FOR

ADDITIONAL INFORMATION.

4. PER NEC 408.4, PANELBOARD SHALL HAVE LABEL

PERMANENTLY AFFIXED INDICATING SOURCE OF SUPPLY

POWER IS LOCATED IN A DIFFERENT BUILDING/FACILITY.

5. FURNISH AND INSTALL 1 1/4" EMPTY CONDUIT WITH PULL

STRING FROM JUNCTION BOX IN WALL TO IN-FLOOR JUNCTION

BOX FOR HDMI CABLE. HDMI CABLE TO BE FURNISHED AND

INSTALLED BY OTHERS.

6. FURNISH AND INSTALL A 60A, 3P NON-FUSED NEMA 1

DISCONNECT SWITCH, SQUARE D MODEL HU362 OR

EQUIVALENT.

7. FURNISH AND INSTALL A 30A, 3P NON-FUSED NEMA 1

DISCONNECT SWITCH, SQUARE D MODEL HU361 OR

EQUIVALENT.

8. MOTOR OPERATE TOGGLE DISCONNECT SWITCH SUPPLIED

WITH UNIT.

9. REFER TO WIRING DIAGRAM ON EP-500 FOR ADDITIONAL

INFORMATION.

10. DISCONNECT SWITCH SUPPLIED WITH UNIT.

SCALE:

N

EP-110

1 FLOOR PLAN - POWER

1/8" = 1'-0"

SCALE:

N

EP-110

2 ENLARGED OFFICE SUITE - POWER

3/16" = 1'-0"

SCALE:

N

EP-110

4 ENLARGED TOILET ROOMS - POWER

1/4" = 1'-0"

EP-110

SCALE:

N

EP-110

3 ENLARGED KITCHEN - POWER

1/4" = 1'-0"

EP-110

EP-110

MICROWAVE

PP-1-15

PP-1-19

PP-1-17

PP-1-19PP-1-17

PP-1-17

REFRIGERATOR

PP-1-13

PP-1-21

PP-1-21

PP-1-22

PP-1-22

PP-1-24

PP-1-24

PP-1-22

PP-1-22

PP-1-21

PP-1-21

PP-1-18

PP-1-20

PP-1-20

PP-1-20

PP-1-20

+48"

PP-1-18

+48"

PP-1-18

+48"

PP-1-8

+48"

PP-1-10

+48"

PP-1-10

+48"

PP-1-10

+48"

PP-1-12

+48"

PP-1-12

+48"

PP-1-12

WP

PP-1-16

WP

PP-1-16

+48"

PP-1-14

PP-1-14

+48"

+48"

PP-1-8+48"

PP-1-8

PP-1-2,4,6

PANEL PP-1

NOTE 4

3/4" C 3-1/C #10

1-1/C #10 GND

OVERHEAD

DOOR

NOTE 1

TO EXISTING

PANEL S2B

NOTE 3

2-2" C

NOTE 3

WP

PP-1-8

SYMBOLS

20A DUPLEX RECEPTACLE

20A GFCI DUPLEX RECEPTACLE

20A GFCI DUPLEX RECEPTACLE - ABOVE COUNTER

DISCONNECT SWITCH

VOICE / DATA OUTLET

20A FLUSH FLOOR DUPLEX RECEPTACLE

WITH VOICE/DATA OUTLETS

20A QUAD RECEPTACLE

20A DUPLEX RECEPTACLE - ABOVE COUNTER

JUNCTION BOXJ

3/4" C 2-1/C #10

1 1/C #10 GND

IWH-2

PP-1-40

IWH-2

IWH-1

IWH-1

PP-1-38

3/4" C 2-1/C #10

1 1/C #10 GND

R-2

TO EF-1

TO EF-1

R-1

PP-1-34

PP-1-36

3/4" C 2-1/C #8 1 1/C #10

3/4" C 2-1/C #8 1 1/C #10

PP-1-26PP-1-26

PP-1-25

TV

PP-1-27

+60" +60"

+60"

NOTE 5

EP-110

3/4" C 3-1/C #8

1-1/C #10 GND

PP-1-47,49,51

EUH-1

NOTE 6

3/4" C 3-1/C #8

1-1/C #10 GND

PP-1-44,46,48

EUH-1

NOTE 6

3/4" C 3-1/C #8

1-1/C #10 GND

PP-1-50,52,54

EUH-1

NOTE 6

SCALE:

N

EP-110

5 EQUIPMENT DECK PLAN - POWER

1/8" = 1'-0"

EC.2

AHU-1

NOTE 7

NOTE 6

PP-1-28,30

PP-1-37,39

3/4" C 2-1/C #10

1 1/C #10 GND

1" C 2-1/C #6

1 1/C #10 GND

ELEC. HEAT

FOR AHU

NOTE 6EF-1

NOTE 9

NOTE 8

3/4" C 2-1/C #10

1 1/C #10 GND

PP-1-32

PP-1-33,35

3/4" C 2-1/C #8

1 1/C #10 GND

+48"

+48"

PP-1-10

PP-1-29

PP-1-31

+48"

TOILET ROOM

TOILET ROOM

KITCHENETTE

PP-1-43,453/4" C

2-1/C #10

1-1/C #10 GND

EWH-1

NOTE 10

PP-1-21

WP

/1

7/

S

TA

TE

O

F M

IC

H

IG

A

N

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N D

E P

A R

TM

E

N T

O F

M

IL

IT

A

R Y

A N

D V

E

TE

R A

N S

A

FF

A

IR

S

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,

COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR

WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022

FOR SITE OWNED UTILITIES

E P

-5

E

LE

C

TR

IC

A

L D

E

TA

IL

S

GENERAL NOTES

A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

NOTES

1. FURNISH AND INSTALL RELAY WITH 120V COILS AND

NORMALLY OPEN (NO) CONTACTS RATED FOR AT

LEAST 5 AMPS AT 120 VAC, INDUCTIVE DUTY.

EXHAUST FAN EF-1 WIRING DIAGRAM

PP-1-5

H N

L LIGHT

TOILET RM

104 SWITCH

C

RELAY R1

NOTE 1

H

PP-1-32

PP-1-5

H N

L LIGHT

TOILET RM

105 SWITCH

C

RELAY R2

NOTE 1

H

PP-1-32

N

EF-1

/1

7/

TE

O

F M

IC

H

IG

A

N

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N D

E P

A R

TM

E

N T

O F

M

IL

IT

A

R Y

A N

D V

E

TE

R A

N S

A

FF

A

IR

S

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,

COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR

WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022

FOR SITE OWNED UTILITIES

E P

-6

E

LE

C

TR

IC

A

L O

N E

-L

IN

E D

IA

G

R A

M

P A

N E

L S

C H

E D

U

LE

S

GENERAL NOTES

A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

NOTES

1. FURNISH AND INSTALL A 200 MCB, 208/120V, 3PH, 4W

PANELBOARD, SQUARE D INTERIOR NQ442L2C WITH BOX

(NEMA 1) CAT #MH50 AND NC50S FRONT AND NQN2CU

NEUTRAL BAR OR EQUIVALENT.

2. FURNISH AND INSTALL A 200A/200AT CIRCUIT BREAKER, GE

MODEL SFHA36AT0200 OR EQUIVALENT.

1-2" C 3-1/C #4/0

1-1/C #6 GND

1-2" C SPARE

EXISTING

PANEL

R2BA

TO EXISTING PANEL D2B

EXISTING

SMOKE

SHACK

60A

EXISTING

SURGE

DEVICE

30A 20A

NEW PANEL

PP-1

NOTE 1

200AF

200AT

NOTE 2

SPARESPARE

EXISTING PANEL S2B: XXXA, 208/120V, 3P, 4W

#4 GND

PARTIAL ONE-LINE DIAGRAM

/1

7/

A B C D E F

D.1C.1

0.5

SLD1SLD1

SL

D1

SL

D1

SL

D1

SL

D1

TOILET ROOM

TOILET ROOM

CONFERENCE ROOM

JANITOR'S CLOSET

OFFICE

HALL

FOYER

OS1

SLD

SLD2

OS2

S L D1

OS1

OS1

SO

S

OS2

SO

S

KITCHENETTE

S L D2

S O

S S

O S

OS1

SLD1

S

TA

TE

O

F M

IC

H

IG

A

N

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N D

E P

A R

TM

E

N T

O F

M

IL

IT

A

R Y

A N

D V

E

TE

R A

N S

A

FF

A

IR

S

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,

COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR

WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022

FOR SITE OWNED UTILITIES

SCALE:

N

EL-110

1 FLOOR PLAN - LIGHTING

1/8" = 1'-0"

SCALE:

N

EL-110

2 ENLARGED OFFICE SUITE - LIGHTING

3/16" = 1'-0"

SCALE:

N

EL-110

4 ENLARGED TOILET ROOMS - LIGHTING

1/4" = 1'-0"

EL-110

SCALE:

N

EL-110

3 ENLARGED KITCHEN - LIGHTING

1/4" = 1'-0"

E L-

E

LE

C

TR

IC

A

L

LI

G H

TI

N

G F

LO

O

R P

LA

N

EL-110

EL-110

GENERAL NOTES

A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

B. DRAWINGS ARE DIAGRAMMATIC ONLY AND INDICATE

GENERAL ARRANGEMENT OF ELECTRICAL WORK.

LOCATIONS ARE APPROXIMATE AND SUBJECT TO MINOR

MODIFICATIONS BY THE OWNER/ENGINEER.

C. COORDINATE EXACT LOCATION OF DEVICES WITH OTHER

TRADES FOR AVOIDANCE OF ANY OBSTRUCTIONS. VERIFY

WALL SWITCHING OF ELECTRICAL LIGHTING PLANS FOR

PROPER TYPES OF OPTIONS REQUIRED ON ALL FIXTURES.

VERIFY CEILING TYPES ON ARCHITECTURAL REFLECTED

CEILING PLANS FOR PROPER INSTALLATIONS OF TRIMS

AND FOR EXACT MOUNTING LOCATIONS ON ALL FIXTURES.

D. USE #12 CONDUCTORS FOR 20A CIRCUIT HOME RUNS IF

BRANCH CIRCUIT RUN IS LESS THAN 100 FEET FOR 120

VOLT. USE #10 CONDUCTORS IF BRANCH CIRCUIT RUN

EXCEEDS 100 FEET FOR 120 VOLT.

E. LIGHTING CONTROL SYSTEM MANUFACTURER IS BASIS OF

DESIGN. ALTERNATE MANUFACTURER AND EQUIPMENT

LISTED THAT MEETS THE SALIENT CHARACTERISTICS OF

THE LIGHTING CONTROL DEVICES LISTED ARE

ACCEPTABLE. THE ENGINEER RESERVES THE RIGHT FOR

THE MANUFACTURER OR MANUFACTURERS

REPRESENTATIVE TO PROVIDE PROOF THAT THE

SELECTED EQUIPMENT MEETS ALL FUNCTIONS, PLANS,

AND SPECIFICATIONS ARE MET OR EXCEEDED. ALL "OR

EQUALS" ARE SUBJECT TO APPROVAL BY

ARCHITECT-ENGINEER.

F. LIGHTING CONTROL AND SENSORS SHOWN ON DRAWINGS

ARE INDICATED TO DEMONSTRATE DESIGN INTENT.

ACTUAL NUMBERS AND LOCATIONS OF DEVICES SHALL BE

AS RECOMMENDED BY THE LIGHTING CONTROL

MANUFACTURER/SUPPLIER. CONTRACTOR SHALL FURNISH

AND INSTALL POWER PACKS, AUXILIARY RELAYS, LOW

VOLTAGE TRANSFORMERS, TRANSFORMER DEVICES, ETC.

AS REQUIRED AND RECOMMENDED BY THE LIGHTING

CONTROL SYSTEM MANUFACTURER/SUPPLIER.

G. LETTER NEXT TO LIGHTING FIXTURE INDICATE FIXTURE

TYPE. REFER TO FIXTURE SCHEDULE ON DRAWING EL-600

FOR ADDITIONAL INFORMATION.

H. REFER TO PANEL SCHEDULE ON DRAWING EP-600 FOR

ADDITIONAL INFORMATION.

I. EMERGENCY AND EXIT LIGHTING FIXTURES TO BE

INSTALLED UNDER THIS CONTRACT SHALL BE FED FROM

THE SAME CIRCUIT AS NORMAL LIGHTING IN SPACE AND

SHALL BE CONNECTED AHEAD OF THE SWITCH.

NOTES

1. FURNISH AND INSTALL WALL MOUNTED OCCUPANCY SENSOR,

SENSOR SWITCH MODEL WSX PDT WH OR EQUIVALENT BY

WATTSTOPPER OR LEVITON.

2. FURNISH AND INSTALL WALL MOUNTED ON/OFF SWITCH WITH

DIMMING, NLIGHT MODEL NPODM DX WH OR EQUIVALENT BY

WATTSTOPPER OR LEVITON.

3. FURNISH AND INSTALL CEILING MOUNTED OCCUPANCY

SENSOR, NLIGHT MODEL NCM PDT 10 AR RJB OR EQUIVALENT

BY WATTSTOPPER OR LEVITON.

4. FURNISH AND INSTALL WALL MOUNTED ON/OFF SWITCH,

NPODM WH OR EQUIVALENT BY WATTSTOPPER OR LEVITON.

5. FURNISH AND INSTALL CEILING MOUNTED OCCUPANCY

SENSOR, SENSOR SWITCH MODEL CM PDT 10 OR EQUIVALENT

BY WATTSTOPPER OR LEVITON

SYMBOLS

WALL MOUNTED OCCUPANCY SENSOR - SEE NOTE 1

WALL MOUNTED ON/OFF SWITCH WITH DIMMING - SEE NOTE 2

CEILING MOUNTED OCCUPANCY SENSOR - SEE NOTE 3

WALL MOUNTED ON/OFF SWITCH - SEE NOTE 4

CEILING MOUNTED OCCUPANCY SENSOR - SEE NOTE 5

SOS

SLD1

SLD2

OS1

OS2

AA

A

A

Y

Y

Y

PP-1-5

PP-1-5

PP-1-7

AA

A A

AA

A A

A

A

A

A

A

X

X

PP-1-9

PP-1-7

Y

Y

PP-1-5

A

A

A

Y

Y PP-1-5

B B

BB

B B

B B

B

BBB

BB

Y

Y

C

PP-1-11 PP-1-9

A A

Y

Y

Y

Y

Y

X Y

PP-1-1

PP-1-3

PP-1-23

CX

PP-1-23

C

X

PP-1-23

C

PP-1-23

C

C

PP-1-11

D

PP-1-11

Y

Y

TOILET ROOM

TOILET ROOM

KITCHENETTE

BB

/1

7/

TE

O

F M

IC

H

IG

A

N

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N D

E P

A R

TM

E

N T

O F

M

IL

IT

A

R Y

A N

D V

E

TE

R A

N S

A

FF

A

IR

S

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,

COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR

WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022

FOR SITE OWNED UTILITIES

E L-

E

LE

C

TR

IC

A

L

LI

G H

TI

N

G F

IX

TU

R E

S C

H E

D U

LE

FIXTURE SCHEDULE

TYPE SIZE AND

MOUNTING

VOLTAGE,

(INPUT WATTAGE)

LAMPS AND

LUMENS

MANUFACTURER /

CATALOG NUMBER REMARKSSYMBOL

GENERAL NOTES

A. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

B. LIGHTING FIXTURE MANUFACTURER AND MODE/SERIES NUMBER

LISTED IN SCHEDULE ARE BASIS OF DESIGN. ALTERNATE

MANUFACTURER AND EQUIPMENT THAT MEETS THE SALIENT

CHARACTERISTICS OF THE LIGHTING FIXTURES LISTED ARE

ACCEPTABLE. THE ENGINEER RESERVES THE RIGHTS FOR THE

MANUFACTURER OR MANUFACTURER'S REPRESENTATIVE TO

PROVIDE PROOF THAT SELECTED EQUIPMENT MEETS ALL

FUNCTIONS, PLANS, AND SPECIFICATIONS ARE MET OR

EXCEEDED. ALL "OR EQUALS" ARE SUBJECT TO APPROVAL BY

ARCHITECT-ENGINEER.

LIGHTING CONTROL SEQUENCE OF

OPERATION

LIGHTING CONTROL SYSTEM HAS BEEN DESIGNED TO MEET SPECIFIC

OPERATIONAL REQUIREMENTS AND FUNCTIONALITY AS FOLLOWS:

1. JC 101, TOILET ROOM 104, TOILET ROOM 105, FOYER 106

a. CONTROLLED BY: LOCAL WALL MOUNTED OCCUPANCY SENSOR

WITH DIMMING CONTROL NEAR DOOR OF EACH ROOM.

b. CIRCUIT CAPABILITY: SINGLE.

c. TIME DELAY: SET FOR 10-MINUTE DELAY.

d. SYSTEM BRANCH: NORMAL.

e. AUTOMATIC SWITCHING MODE: AUTOMATIC ON; MANUAL OR

AUTOMATIC OFF.

2. HALL 107

a. CONTROLLED BY: LOCAL CEILING MOUNTED OCCUPANCY

SENSOR(S) WITH LOCAL WALL MOUNTED ON/OFF WALLPODS AT

MAIN ACCESS DOOR(S) FOR MANUAL OVERRIDE OF AUTOMATIC

CONTROL.

b. CIRCUIT CAPABILITY: SINGLE.

c. TIME DELAY: SET FOR 10-MINUTE DELAY.

d. SYSTEM BRANCH: NORMAL.

e. AUTOMATIC SWITCHING MODE: AUTOMATIC ON; MANUAL OR

AUTOMATIC OFF.

3. OFFICE 100, KITCHENETTE 102, CONFERENCE ROOM 103

a. CONTROLLED BY: LOCAL CEILING MOUNTED OCCUPANCY

SENSOR(S) WITH LOCAL WALL MOUNTED ON/OFF DIMMER

SWITCHES AT MAIN ACCESS DOOR(S) OR ENTRANCE FOR

MANUAL OVERRIDE OF AUTOMATIC CONTROL.

b. CIRCUIT CAPABILITY: SINGLE.

c. TIME DELAY: SET FOR 10-MINUTE DELAY.

d. SYSTEM BRANCH: NORMAL.

e. AUTOMATIC SWITCHING MODE: MANUAL ON; MANUAL OR

AUTOMATIC OFF.

4. WAREHOUSE

a. CONTROLLED BY: INTEGRAL FIXTURE MOUNTED OCCUPANCY

SENSORS SHALL ILLUMINATE ALL FIXTURES TO 100% UPON

ENTRY OF PERSONNEL AT ANY ENTRY POINT. ALL FIXTURES

SHALL REDUCE TO 30% AFTER OCCUPANCY SENSORS DO NOT

DETECT ACTIVITY IN A LIGHTING ZONE FOR 20 MINUTES AND

SHALL SHUT OFF COMPLETELY AFTER 30 MINUTES OF NO

DETECTION. LOCAL WALLPODS AT MAIN ACCESS DOORS SHALL

BE PROVIDED FOR MANUAL OVERRIDE OF AUTOMATIC CONTROL.

b. CIRCUIT CAPABILITY: SINGLE.

c. TIME DELAY: 30% AT 20 MINUTES, OFF AT 30 MINUTES.

d. SYSTEM BRANCH: NORMAL.

e. AUTOMATIC SWITCHING MODE: AUTOMATIC ON; MANUAL OR

AUTOMATIC OFF.

NOTES

1. MOUNT BOTTOM OF FIXTURE AT 14'-0" ABOVE FINISHED FLOOR.

2. MOUNT BOTTOM OF FIXTURE 2" ABOVE DOOR FRAME.

3. MOUNT BOTTOM OF FIXTURE 16'-0" ABOVE FINISHED FLOOR.

4. MOUNT BOTTOM OF FIXTURE 8'-0" ABOVE FINISHED FLOOR.

5. FIXTURE SHALL MEET NFPA LIFE SAFETY CODE 101 AND BE

LISTED UNDER UL924.

6. FOR FIXTURES WITH HALF-SHADING ON FLOOR PLAN, FURNISH

AND INSTALL FIXTURE WITH EL14L BATTERY PACK.

A 2' X 4'

(NOMINAL)

TROFFER

120V (25W)

4000K

WHITE LIGHT

EMITTING

DIODES

3,097 LUMENS

(NOMINAL)

LITHONIA "TL LED" SERIES

2TL4 30L FW A12 GZ10 LP840

13"

(NOMINAL)

HIGH BAY

FIXTURE

120V (95W)

4000K

WHITE LIGHT

EMITTING

DIODES

13,630 LUMENS

(NOMINAL)

LITHONIA "JEBL" SERIES

JEBL 12000LM GL MVOLT

40K 80CRI WBF SBOR10

DWHXD

MANDOOR

FIXTURE

120V (17W)

4000K

WHITE LIGHT

EMITTING

DIODES

2,151 LUMENS

(NOMINAL)

LITHONIA "ARC1LED" SERIES

ARC1 LED P2 40K MVOLT E4WH

PE DDBXD

B

C

OVERHEAD

DOOR

FIXTURE

D

120V (51W)

4000K

WHITE LIGHT

EMITTING

DIODES

6,615 LUMENS

(NOMINAL)

LITHONIA "ARC 2 LED" SERIES

ARC2 LED P5 40K MVOLT PE

DDBXD

X

Y

EXIT

LIGHT

CEILING OR WALL

MOUNT

SURFACE

MOUNTED

EMERGENCY

FIXTURE

120V (4.3W)

120V (4.77)

RED LIGHT

EMITTING

DIODES

2-LED

FLOOD

LAMPS

LITHONIA "LQHM" SERIES

LHQM LED HORO

LITHONIA "ELM6L" SERIES

ELM6L UVOLT LTP SDRT HO

SEE NOTE 1

SEE NOTE 2

SEE NOTE 3

SEE NOTE 4, 5

SEE NOTE 4, 5

SEE NOTE 6

/1

7/

D.1C.1

0.5

0.5

SCALE:

N

M-110

1 FLOOR PLAN - HVAC

1/8" = 1'-0" SCALE:

N

M-110

2 ENLARGED OFFICE SUITE - HVAC

1/4" = 1'-0"

M-110

C.1 D.1

ST

AT

E O

F M

IC

H

IG

AN

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

D

EP

AR

TM

EN

T

O F

M

IL

IT

AR

Y

AN

D V

ET

ER

AN

S

AF

FA

IR

S

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,

COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR

WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022

FOR SITE OWNED UTILITIES

M -1

H

VA

C F

LO

O

R P

LA

N

S

EC.2

WAREHOUSE

J.C.

OFFICE

TLT.

TLT.

CONFERENCE

FOYER

KITCHENETTE

HALL

SCALE:

N EQUIPMENT DECK PLAN - HVAC

1/8" = 1'-0"

EC.2

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

FILE NO./INDEX CODE:

AutoCAD SHX Text

PROJECT NO.:

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM P. LACH,RA, DIRECTOR

AutoCAD SHX Text

SHEET TITLE:

AutoCAD SHX Text

UTILITIES

AutoCAD SHX Text 989-344-6184

AutoCAD SHX Text

72 HOURS

AutoCAD SHX Text

(3 WORKING DAYS)

AutoCAD SHX Text

CALL MR. HALCOMB

AutoCAD SHX Text

BEFORE YOU DIG

AutoCAD SHX Text C.G.

AutoCAD SHX Text

FACILITIES MANAGEMENT

AutoCAD SHX Text

CAMP GRAYLING ENGINEERING

kgilson Cyril Seal

ST

AT

E O

F M

IC

H

IG

AN

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

D

EP

AR

TM

EN

T

O F

M

IL

IT

AR

Y

AN

D V

ET

ER

AN

S

AF

FA

IR

S

C

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,

COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR

WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022

FOR SITE OWNED UTILITIES

M -9

H

VA

C S

C H

ED

U

LE

S

/0 3/

C M

KW

G

C M

R M R

/1 7/

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

FILE NO./INDEX CODE:

AutoCAD SHX Text

PROJECT NO.:

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM P. LACH,RA, DIRECTOR

AutoCAD SHX Text

SHEET TITLE:

AutoCAD SHX Text

UTILITIES

AutoCAD SHX Text 989-344-6184

AutoCAD SHX Text

72 HOURS

AutoCAD SHX Text

(3 WORKING DAYS)

AutoCAD SHX Text

CALL MR. HALCOMB

AutoCAD SHX Text

BEFORE YOU DIG

AutoCAD SHX Text C.G.

AutoCAD SHX Text

FACILITIES MANAGEMENT

AutoCAD SHX Text

CAMP GRAYLING ENGINEERING

D.1C.1

0.5

M

0.5

M

SCALE:

N

P-110

1 FLOOR PLAN - PLUMBING & PIPING

1/8" = 1'-0" SCALE:

N

P-110

2 ENLARGED OFFICE SUITE - PLUMBING & PIPING

3/16" = 1'-0"

P-110

ST

AT

E O

F M

IC

H

IG

AN

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

D

EP

AR

TM

EN

T

O F

M

IL

IT

AR

Y

AN

D V

ET

ER

AN

S

AF

FA

IR

S

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

SIDOCK GROUP, INC. AND CANNOT BE REPRODUCED,

COPIED, OR USED IN ANY MANNER WITHOUT THE PRIOR

WRITTEN CONSENT OF SIDOCK GROUP, INC. 2022

FOR SITE OWNED UTILITIES

P-

PL

U

M

BI

N G

P

IP

IN

G F

LO

O

R P

LA

N

S

EC.2

WAREHOUSE

J.C.

OFFICE

TLT.

TLT.

CONFERENCE

FOYER

KITCHENETTE

SCALE:

N

EQUIPMENT DECK PLAN - HVAC

1/8" = 1'-0"

EC.2

5'-0"

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

FILE NO./INDEX CODE:

AutoCAD SHX Text

PROJECT NO.:

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM P. LACH,RA, DIRECTOR

AutoCAD SHX Text

SHEET TITLE:

AutoCAD SHX Text

UTILITIES

AutoCAD SHX Text 989-344-6184

AutoCAD SHX Text

72 HOURS

AutoCAD SHX Text

(3 WORKING DAYS)

AutoCAD SHX Text

CALL MR. HALCOMB

AutoCAD SHX Text

BEFORE YOU DIG

AutoCAD SHX Text C.G.

AutoCAD SHX Text

FACILITIES MANAGEMENT

AutoCAD SHX Text

CAMP GRAYLING ENGINEERING

512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 21
512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 22
512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 23
512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 24
512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 25
512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 26
512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 27
512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 28
512-23121.JLM Chesterfield - Sidock - IFC Drawings 12-4-23 29

File details come from the government source that posted it. Updated .