This document is an Addendum (No. 1) issued by U.P. Engineers & Architects, Inc. for the Department of Military and Veterans Affairs (DMVA) to renovate the Kingsford Armory located in Kingsford, Michigan. The addendum, dated August 14, 2025, modifies the original project plans and specifications, with File No. 511/22033.JBB. Key modifications include adding specification sections for Exterior Insulation and Finish Systems, Aluminum Windows, and a Security Vault Door, as well as revising door hardware specifications and making adjustments to various architectural and structural drawing details.
The addendum provides clarifications on multiple aspects of the renovation, including changes to door hardware sets, kitchen equipment specifications, and structural elements. Attached documents include a mandatory pre-bid walkthrough sign-in sheet, a request for information (RFI) log with contractor questions and answers, and a preliminary submittal log. The changes encompass various technical specifications, such as replacing certain door hardware, updating food service equipment descriptions, and providing revised structural drawings for multiple project sheets. Contractors are instructed to acknowledge receipt of the addendum on their bid form and include it with their bid package.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
100 Portage Street Houghton, MI 49931
906-482-4810 • 800-562-7684 • Fax: 906-482-9799
Offices also in:
Iron Mountain
Ishpeming Marinette
Sault Ste. Marie
U.P. Engineers & Architects, Inc.
www.UPEA.com
[M12-05209]
ADDENDUM NO. 1
TO THE
Department of Military and Veterans Affairs Renovate Kingsford Armory
Kingsford, MI
ADDENDUM NO. 1 is issued August 14, 2025, to clarify, modify, and/or change the original plans and specifications issued by UP Engineers and Architects. This ADDENDUM NO. 1 is hereby made part of the Contract Documents for the contract noted below.
File No. 511/22033.JBB DMVA Renovate Kingsford Armory
Please acknowledge receipt of this ADDENDUM NO. 1 on the appropriate blank on the Bid Form and also include this addendum with the bid package.
GENERAL
1. See attached mandatory pre-bid walkthrough sign-in sheet.
2. See attached RFI log with Contractor questions and PSC and DMVA answers.
3. See attached preliminary Submittal Log.
SPECIFICATIONS
1. ADD Specification Section 07 24 00 – Exterior Insulation and Finish Systems attached to this Addendum.
2. ADD Specification Section 08 51 13 – Aluminum Windows attached to this Addendum.
3. Specification Section 08 71 00 – Door Hardware
a. REPLACE Door Hardware Set 5 with the following:
i. 3 EA HINGES
ii. 1 EA PUSH PLATE
iii. 1 EA PULL PLATE
iv. 1 EA DEAD BOLT (THUMB TURN w/ CORE ON DRILL HALL
SIDE)
v. 1 BEST 7 PIN 1CX7 CORE
vi. 1 ARMOR PLATE
vii. 1 SURFACE CLOSER
viii. 1 WALL STOP
511/22033.JBB Renovate Armory Kingsford Addendum #1 Page 2 of 4
ix. 1 FLOOR STOP
b. All hardware shall be of same type as noted in this specification section.
4. ADD Specification Section 11 10 00 - Security Vault Door attached to this Addendum.
5. Specification Section 11 40 00 - Food Service Equipment
a. 1.1; A; 1: REMOVE “Owner-supplied food service equipment”. Only equipment provided by the Owner is double convection oven, commercial gas range, and dishwasher. The contractor shall provide the rest per Drawing Sheet K101 and this Addendum.
6. Specification Appendix III. REPLACE Federal Wage Determination information with updated Federal Wage Determination information attached to this Addendum.
PLANS
1. Drawing Sheet A001:
a. Signage and Door Hardware Mounting: Sign mounting height shall be “Match height noted on Drawing Sheet A606”.
2. Drawing Sheet AD101:
a. ADD Keynote 41 to read: “REMOVE VAULT DOOR AND FRAME. PREP FOR PROPOSED DOOR PER SPECIFICATIONS”. Keynote shall apply to vault door located between Vault Entry B023 (existing number on this sheet) and Vault B006 (existing number on this sheet).
3. Drawing Sheet AD102:
a. Door between Lobby 100 (existing number on this sheet) and Office 104 (existing number on this sheet) demolition includes surrounding borrowed lites. Infill with Wall Type 7.
b. ADD the following to the end of Keynote 40: “CONTRACTOR SHALL
REMOVE ALL APPURTENANCES ATTACHED TO CEILING FROM
CEILING IN DRILL HALL. CONTRACTOR SHALL BE RESPONSIBLE
FOR RELOCATING AS REQUIRED.”
4. Drawing Sheet S001. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
5. Drawing Sheet S101. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
6. Drawing Sheet S102. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
7. Drawing Sheet S301. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
8. Drawing Sheet S501. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
9. Drawing Sheet S502. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
Addendum #1 Page 3 of 4
10. Drawing Sheet S503. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
11. Drawing Sheet A101:
a. Opening between Office B002 and Supply B003 shall be Borrowed Lite B2 per the schedule included in this Addendum below.
b. Wall Type Schedule: All slip track information that contradicts information on revised structural drawings shall be removed. Structural drawings shall govern.
c. Wall Type Schedule: CHANGE reference to 3/S503 on wall type 7C to 4/S503.
12. Drawing Sheet A102:
a. Door 126 is an HM frame door per Sheet A602 and borrowed lites are removed per Addendum notes for Sheet AD102.
13. Drawing Sheet A401:
a. Details 8/A401 and 9/A401: REMOVE callout to 8/A502. This detail is NOT a cage detail. Cage shall be per Specification Section 10 22 13 – Wire Mesh Partitions.
b. REPLACE Detail 12/A401 with detail attached to this Addendum.
14. Drawing Sheet A402:
a. ADD counter detail attached to this Addendum. Counter detail shall represent all counters called out on this sheet.
15. Drawing Sheet A502:
a. Detail 8/A502: CHANGE label to “Vault Penetration Detail”. This is a vault wall penetration detail, not a cage detail.
16. Drawing Sheet A602:
a. Door 208A shall have Hardware Set 3 included in original Specifications.
b. Door 103C shall have Revised Hardware Set 5 included in Specification Section of this Addendum.
c. Revised Door Types included below to REPLACE Door Types.
d. Borrowed Lite Schedule and Types: REPLACE Borrowed Lite Schedule and Borrowed Lite Types with those included below.
17. Drawing Sheet A603. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
18. Drawing Sheet A604. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
19. Drawing Sheet A605. REPLACE Sheet in its entirety with Sheet attached to this Addendum.
20. Drawing Sheet A606. ADD Sheet to the Bid Documents. Not previously included.
21. Drawing Sheet K101. REPLACE Plan 1/K101 with Plan included in this addendum.
Addendum #1 Page 4 of 4
END OF ADDENDUM NO. 1
Prepared by:
U.P. Engineers & Architects, Inc Attachments:
Pre-bid sign-in sheet Pre-bid RFI log with PSC and DMVA answers Preliminary Submittal log Specification Section 07 24 00 Specification Section 08 51 13 Specification Section 11 10 00 Revised drawings as noted above Revised Drawing Sheet S001 Revised Drawing Sheet S101 Revised Drawing Sheet S102 Revised Drawing Sheet S301 Revised Drawing Sheet S501 Revised Drawing Sheet S502 Revised Drawing Sheet S503 Revised Drawing Sheet A603 Revised Drawing Sheet A604 Revised Drawing Sheet A605 Drawing Sheet A606
DMVA Renovate Kingsford Armory Bid RFIs Page 1 of 9
Department of Military and Veterans Affairs Renovate Kingsford Armory
Kingsford, MI
Bid RFIs List
Modification Date: 8-14-2025
RFI#001
Spec Section: 10 28 00 – Toilet, Bath, and Laundry Accessories
Drawing: NA
Contractor Question:
I would just like to confirm the part number for the hand dryers on the Kingsford Armory Renovation project. The spec sheet shows the World Dryer VERDEdri #Q-972A2 as basis of design. That is a
“Polished” Stainless Steel cover. The Wall Guards listed in the spec only come in a “Brushed” Stainless
Steel. We do have the hand dryer in a “brushed” finish and that would be part #Q-973A2.
PSC Answer:
This is done intentionally. The owner knows this, and this is what they want.
RFI#002
Spec Section: NA
For this project the specifications for the Steam Finned Tube, Unit Heater, Cabinet Heater and Steam Coil are missing from the mechanical specifications.
Use the schedule models/makes as a basis for design for these items.
RFI#003
Drawing: M602, M603
I see that Control Contractor on the MEP drawings in ACC. Are they going to be the controls contractor that the armory wants? If so are they bidding out to the GC alone or going through the Mechanical
Contractor like we normally do?
Through the mechanical contractor.
DMVA Renovate Kingsford Armory Bid RFIs Page 2 of 9
RFI#004
Drawing: A501
Stairway 001 top landing info?? What is it made of? Wall rails on one side? or both sides? Section 1/A501 shows multi-line pipe railing, but is this on one side, or both?
Top landing is part of the second floor. Landing is concrete with reinforcing the same as the second floor.
Landing shall be formed to match stair profile. The rail on the West side shall be the pipe railing shown.
The rail on the East side may be a wall railing at the height shown for the top rail of the pipe railing. All rails shall extend 1’-0” at the top and bottom as shown on 1/A501.
RFI#005
Drawing: S102, S502
Are there any Beam bearing plates required at B1 & B4 beams? No details.
Bearing plate information provided on revised structural drawings
RFI#006
Drawing: S102, S502
Are there any Joist bearing plates required? No details really, just 1/S502 & 6/S502 which actually don't give any info. Are there to be Joist bearing plates at 5/S502? on dwg. S102
Bearing plate information provided on revised structural drawings
RFI#007
Drawing: S102
B4 Beams above restrooms/showers on dwg. S102 - need a detail & section view for these, to see how they are to fit, or sit on joist?
Beams removed. Reference revised structural drawings for detail.
DMVA Renovate Kingsford Armory Bid RFIs Page 3 of 9
RFI#008
Drawing: S101, S102
B3 Ledger Angles on Dwg's. S101 & S102 - do they need expansion anchors? if so, spacing & type of anchors?
Epoxy anchors will be used. Additional information on revised structural drawings.
RFI#009
Spec Section: 28 31 11 – Digital Addressable Fire Alarm, 2.3 Fire Alarm Control Unit
The specifications for the Fire Alarm system indicate that the control panel should be model EST iO64 or an equivalent approved by the engineer. Could you please confirm whether Simplex would be accepted as an approved system manufacturer?
PSC and DMVA Answer:
No. Simplex is not approved.
The only two system manufacturers allowed are as follows:
1. Edwards Systems Technology: General Signal Unit.
2. National Tiem and Signal Company (Wixom, MI)
RFI#010
Spec Section: 08 33 23 Overhead Coiling Doors
Spec calls out 5 year warranty. Warranty of specified door is 2 years. Please advise.
Spec calls for fire rating. Please confirm if this is required.
Counter doors cannot be hand chain. Should the counter doors be hand crank or push up?
Two year warranty is all that is available for specified door. Two year warranty is acceptable.
Door shall be fire rated with fusible link to fire alarm. Door shall be 1-hr rated minimum.
Counter doors can be hand chain per Cornell. Basis for design shall be Cornell Alarm-Guard Chain
Operator.
DMVA Renovate Kingsford Armory Bid RFIs Page 4 of 9
RFI#011
Spec Section: 11 40 00 Food Service Equipment
Please confirm if the Food Service Equipment and Kitchen Equipment on sheet K101 is contractor provided. The spec says, “Owner-supplied food service equipment”.
PSC and DMVA Answer:
Only Owner supplied equipment is the double convection over, commercial gas range, and the dishwasher. The contractor shall provide the remaining per Drawing Sheet K101 and additional information in this Addendum.
RFI#012
Drawing: K101
i. Item# 4B - Chicago Faucet - Model# 923-XKCAB - The description calls for a deck mount faucet but the model number given is for a wall/splash mount faucet.
ii. Item# 3 - 2 each, Salvajor Garbage Disposal - Model# 5HP - Are controls needed? If so, what control package is required?
iii. Item # 5 - Commercial Stainless - Model# C2CSD - Verify dimensions required?
iv. Item # 6 - Eagle Group - Custom - Custom stainless counter - Verify dimensions required?
v. Item# 16 - Just - Custom - Large Well Sink - Verify dimensions required?
vi. Item# 17 - Just - Custom - Soaking Sink - Verify dimensions required?
vii. Item#18 - Just - Custom - Rinsing Sink - Verify dimensions required?
viii. Item# 30 - Custom - Dish Return Table & Trough - Verify dimensions required?
ix. Item# 31 - Custom - Circular Rinsing Sink - Verify dimensions required?
x. Item# 32 - Randell - Model# Ran 14G IC-4 - Mobile Salad Bar - Verify if a sneezeguard is required, if so what sneezeguard option is required. Verify if tray slides are required, if so on which side of the salad bar and what tray slide option? Inverted "V" tray slide, Flat tray slide, or
3-bar tubular tray slide? Operators side, customer side or both sides? Folding tray slide or stationary?
PSC and DMVA Answers in red:
i. Item# 4B - Chicago Faucet - Model# 923-XKCAB - The description calls for a deck mount faucet but the model number given is for a wall/splash mount faucet.
a. Faucet should be wall mount per the model number. Description is incorrect.
ii. Item# 3 - 2 each, Salvajor Garbage Disposal - Model# 5HP - Are controls needed? If so, what control package is required?
a. Controls are required, package ARSS-2 (automatic reversing)
iii. Item # 5 - Commercial Stainless - Model# C2CSD - Verify dimensions required?
a. 18” deep x 24” wide x 18” long
iv. Item # 6 - Eagle Group - Custom - Custom stainless counter - Verify dimensions required?
a. Reference revised kitchen plan details.
v. Item# 16 - Just - Custom - Large Well Sink - Verify dimensions required?
a. 36” long x 28” wide x 18” deep
DMVA Renovate Kingsford Armory Bid RFIs Page 5 of 9
vi. Item# 17 - Just - Custom - Soaking Sink - Verify dimensions required?
a. 18” long x 28” wide x 18” deep
vii. Item#18 - Just - Custom - Rinsing Sink - Verify dimensions required?
a. 18.5” long x 28” wide x 18” deep
viii. Item# 30 - Custom - Dish Return Table & Trough - Verify dimensions required?
a. Trough is 7” wide x 3” to 5” sloping depth to sink. Reference revised kitchen plan details for counter dimensions.
ix. Item# 31 - Custom - Circular Rinsing Sink - Verify dimensions required?
a. CHANGE to a rectangular sink. Sink size: 24” wide x 24” long x 14” deep.
x. Item# 32 - Randell - Model# Ran 14G IC-4 - Mobile Salad Bar - Verify if a sneezeguard is required, if so what sneezeguard option is required. Verify if tray slides are required, if so on which side of the salad bar and what tray slide option? Inverted "V" tray slide, Flat tray slide, or 3-bar tubular tray slide? Operators side, customer side or both sides?
Folding tray slide or stationary?
a. Sneezeguard is required on canopy and over shelves. Slides are required on enclosed base side. Back side is open with no slides. Provide three (3) tubular tray slides that are folding.
RFI#013
Drawing: A501
What is the makeup of the rail system shown. Can a view be provided for the rail on the other side of the stairs?
Rail on other side (East) side of the stairs is a wall mounted rail with extensions as shown on 1/A501.
RFI#014
Drawing: Structural
i. Question: Are there any Beam bearing plates required at B1 & B4 beams?
ii. Question: Are there any Joist bearing plates required at1/S502, 5/S502, and 6/S502 ?
iii. Can additional detail be provided for the bearing/joist detail of the B4 beams on detail 2, sheet
S102.
iv. Are expansion anchors required for B3 Ledger Angles? If so, please provide detail and/or sizing and spacing.
Reference revised structural drawings.
DMVA Renovate Kingsford Armory Bid RFIs Page 6 of 9
RFI#015
Drawing: MP001
I see they only want soldered copper only and no press. Is that 100% certain that no propress is accepted?
That is correct for domestic water.
RFI#016
Drawing: E603, E604
The specs say that the drawings will confirm AIC ratings for the panels, but that information is blank on the panel schedules.
Please confirm the AIC rating required
Drawing E502 One-Line Diagram has AIC rating requirements for all new panels.
RFI#017
Spec Section: 26 05 33 Raceway and Boxes for Electrical Systems
Drawing: E503
The drawings show wiremold in room 216, is wiremold also used on detail 1 of drawing E503? In the specs for wireway it states no wiremold. Just want to make sure wiremold is required.
Detail 1/E503 applies to the 2 basement classrooms, room 113, and classroom 217, TV locations.
Conduits shown on detail 1/E503 shall be in new walls (not surface mounted in the basement classrooms or room 113).
Metal surface wiremold will be required for TV locaton in classroom 217.
Metal surface wiremold will be required for any existing walls for new devices.
RFI#018
Spec Section: 26 05 33 Raceway and Boxes for Electrical Systems
Drawing: E503
What series wiremold is acceptable for existing walls with new devices?
Wiremold 700 would be acceptable for individual drops for receptacles and light switches.
DMVA Renovate Kingsford Armory Bid RFIs Page 7 of 9
The TV setup in classroom 217 will need something larger (like Wiremold 2000 or 2400) between the high & low boxes.
RFI#019
Drawing: A602
Door Schedule – Openings 103C & 208A have no hardware sets designated. Please advise.
Reference revised door schedule. Hardware set 5 revised in this Addendum.
RFI#020
Spec Section: 10 28 00 Toilet, Bath, and Laundry Accessories
Substitution submitted for hand dryers.
This substitution is not acceptable. Different DMVA locations need to be able to share spare parts, and no other locations have this product.
RFI#021
Drawing: AD102
Keynote 23 on AD102 says to prep terrazzo for refinishing. The finish schedule does not include Lobby
100. Is there new flooring being installed over the terrazzo? Or do we need to get a terrazzo contractor to patch/repair/etc?
Lobby is new room number 129. Lobby is on Room Finish Schedule. Existing terrazzo shall be refinished. No new floor is going on top of terrazzo.
DMVA Renovate Kingsford Armory Bid RFIs Page 8 of 9
RFI#022
Drawing: Structural
What is the existing first floor deck over the basement area that is to be demoed? Will shoring be required prior to this slab removal?
Existing floor is precast concrete. Shoring is required. Contractor shall be responsible for all shoring, including shoring methods.
RFI#023
Drawing: A402
Do you have details for the countertops shown on the elevations on A402?
Details provided in this Addendum.
RFI#024
Drawing: A502
Is detail 2/A502 calling for EIFS on the exterior of the stud infill?
Yes. EIFS to match existing. A spec will be provided in this Addendum.
RFI#025
There is no spec for Window Type 1 on sheet A602. Please provide spec or further clarification for make and finish.
A spec will be provided in this Addendum.
DMVA Renovate Kingsford Armory Bid RFIs Page 9 of 9
RFI#026
a. Please clarify the glass type for NG type doors.
b. Please provide an elevation view of door type HG and provide glass type, if required.
Reference revised door schedule and details attached to this Addendum.
All glazing shall be per Specification Section 08 80 00 Glazing in the Bid Specifications.
RFI#027
Drawing: A101
There seems to be an opening of some sort in the new wall between Office B002 and B003 but there is no designation. Please clarify the opening type.
This is a borrowed lite. Details and additional information provided in this Addendum.
Submittal/Shop Drawing Log 511.22033.JBB
TBD
Submittal/Shop Drawing Log Not recieved 7/10/2025
Kingsford Armory Reviewed and Approved
Missing from Submital
Reviewed and Not Approroved
A P
P R
O V
ED
A P
P R
O V
ED
A
S N
O
TE
D
R
EV
IS
E
S
EN
D
R
EC
O R
D C
O P
Y
N O
T A
P P
R O
V
ED
N O
T R
EV
IS
ED
DATE SENT
BACK TO
GC
C O
N
TR
A C
TO
R
ST
A
TE
IN
SP
EC
TO
R
02 4119 Existing Conditions Selective builing demolition Demolition Schedule Indicate overall schedule and interruptions required for utility and building services
03 2000 Concrete Concrete Reinforcement Shop drawings 03 3000 Concrete Cast-in-Place Concrete Product Data Admixtures and concrete mix design 03 3000 Concrete Cast-in-Place Concrete Product Data Mix for Vault Walls 03 3500 Concrete Concrete Finishing Product Data Submit data on sealer, compatibilites and limitations 03 3900 Concrete Concrete Curing Product Data Submit data on sealer, compatibilites and limitations
03 5400 Concrete Cast Underlayment Product Data
1. Submit physical characteristics, product limitations, and component sources.
2. Submit Procedures for Attaching Finished Floor Goods to cast underlayment
3. Manufacturer’s guide for building conditions required for installation.
03 5400 Concrete Cast Underlayment Manufacturer's Certificate Certify products meet or exceed specified requirements
03 5400 Concrete Cast Underlayment Manufacturer's Installation Instructions Indicate mix and application requiremnts
03 5400 Concrete Cast Underlayment Qualifications Statements Submit qualifications for manufacturer and applicator.
04 0513 Masonry Masonry Mortering Design Data Submit design mix when Property specification of ASTM C270 is to be used, required environmental conditions, and admixture limitations
04 0513 Masonry Masonry Mortering Test Reports Submit reports on mortar indicating conformance of mortar to property requirements of ASTM C270 04 0513 Masonry Masonry Mortering Manufacturer's Certificate Certify products meet or exceed specified requirements 04 0516 Masonry Masonry Grouting Manufacturer's Certificate Certify that products meet or exceed specified requirements
04 0516 Masonry Masonry Grouting Test and Evaluation Reports
Submit compliance with grout property requirements according to
ASTM C476, component grout materials according to ASTM C476, and test and evaluation reports according to ASTM C1019.
04 2000 Masonry Unit Masonry Product Data Prefaced and regular masonry units 04 2000 Masonry Unit Masonry Product Data Fabricated wire reinforcement 04 2000 Masonry Unit Masonry Product Data Wall ties 04 2000 Masonry Unit Masonry Product Data Anchors 04 2000 Masonry Unit Masonry Product Data Cavity insulation 04 2000 Masonry Unit Masonry Manufacturer's Certificate Certify that products meet or exceed specified requirements 04 2000 Masonry Unit Masonry Source Quality-Control Submittals Indicate results of factory tests and inspections
04 2000 Masonry Unit Masonry Qualifications Statements Submit qualifications for installer
05 2100 Metals Joists Shop Drawings
1.Indicate standard designations, configuration, sizes, spacing, locations of joists, joist leg extensions.
2.Joist coding, bridging, connections, attachments, and details.
3.Cambers.
4.Connection details.
5.Design top chord leg extensions to meet loading specified on construction plans.
ACTION
COMMENTS
COPIES TO
D M
V A
A P
P R
O V
ED
Required Prior to Start of Construction
Required Material Submittals
SU
B
M
IT
TA
L
N U
B M
ER
CSI
CAT.
CSI
PHASE
CSI CATEGORY
DESCRIPTION
CSI PHASE DESCRIPTION ITEM DESCRIPTION TYPE ITEM DESCRIPTION
SUBCONTRACTOR/S
UPPLIER
DATE
RECEIVED
Project:
File No:
Contractor:
05 2100 Metals Joists Manufacturer's Certificate Certify products meet or exceed specified requirements.
05 2100 Metals Joists Product Data Decking Nails
05 3123 Metals Decking Shop Drawings Indicate deck plan, support locations, Projections, openings, pertinent details, and accessories
05 3123 Metals Decking Product Data Submit deck profile characteristics and dimensions, structural properties, finishes 05 3123 Metals Decking Manufacturer’s Certificates Certify Products meet or exceed specified requirements 05 3123 Metals Decking Product Data Decking Nails
05 4000 Metals Cold Formed Metal Framing Product Data Submit data on standard framing members; describe materials and finish, product criteria
05 4000 Metals Cold Formed Metal Framing Manufacturer's Installation Instructions Submit special procedures, and perimeter conditions requiring special attention.
05 5000 Metals Metal Fabrications Shop Drawings
Indicate profiles, sizes, connection attachments, reinforcing, anchorage, size and type of fasteners, and accessories Erection drawings, elevations, and details where applicable. Indicate welded connections using standard AWS A2.0 welding symbols. Indicate net weld lengths.
05 5000 Metals Metal Fabrications Welders Certificates Certify welders employed on the Work, verifying AWS qualification within previous 12 months
05 5000 Metals Metal Fabrications Manufacturer's Certificate Provide manufacturer’s certificate that materials are processed in the
United States
06 1053 Woods and Plastics Miscellaneous rough carpentry Product Data Submit technical data and application instructions on wood-preservative and fire-retardant treatment materials
06 1053 Woods and Plastics Finish Carpentry Product Data Preservative treatment materials and application instructions.
06 1053 Woods and Plastics Finish Carpentry Shop Drawings Indicate materials, component profiles, fastening methods, jointing details, accessories to minimum scale of 1-1/2 in to 1 ft.
06 1053 Woods and Plastics Finish Carpentry Samples Submit two samples of wood frames 10 inches long
07 2113 Thermal &
Moisture Protection Board Insulation Product Data
Submit manufacturer information on product characteristics, performance criteria, limitations and adhesives
07 5303 Thermal &
Moisture Protection Elastomeric Membrane Roofing Shop Drawings
Indicate setting plan for tapered insulation, joint and termination detail conditions, conditions of interface with other materials. Indicate membrane layout and seam locations
07 5303 Thermal &
Moisture Protection Elastomeric Membrane Roofing Product Data
Submit characteristics on membrane materials, adhesives, seaming materials, flashing materials, insulation, and vapor retarders.
07 5303 Thermal &
Moisture Protection Elastomeric Membrane Roofing Sample Warrenty
Copy of roofing system manufacturer's warranty stating obligations, remedies, limitations, duration of warranty, 72 MPH limit winds, and exclusions of warranty
07 5303 Thermal &
Moisture Protection Elastomeric Membrane Roofing Samples Submit two, 6x6 inch in size illustrating insulation, adhesive, membrane
07 5303 Thermal &
Moisture Protection Elastomeric Membrane Roofing Manufacturer's Installation Instructions Submit special precautions required for seaming
07 6200 Thermal &
Moisture Protection Sheet Metal Flashing and Trim Shop Drawings
Indicate material profile, jointing pattern, jointing details, fastening methods, flashings, terminations, and installation details.
07 6200 Thermal &
Moisture Protection Sheet Metal Flashing and Trim Product Data
Submit data on manufactured components metal types, finishes, and characteristics
07 6200 Thermal &
Moisture Protection Sheet Metal Flashing and Trim Samples Submit two samples 2x2 inch in size illustrating metal finish color.
07 7200 Thermal &
Moisture Protection Roof accessories Poduct Data
For each type of roof accessory indicated. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes.
07 7200 Thermal &
Moisture Protection Roof accessories Shop Drawings
For roof accessories. Include plans, elevations, keyed details, and attachments to other work. Indicate dimensions, loadings, and special conditions. Distinguish between plant- and field-assembled work.
07 7200 Thermal &
Moisture Protection Roof accessories Coordination Drawings
Roof plans, drawn to scale, and coordinating penetrations and roof-mounted items. Show the following:
1. Size and location of roof accessories specified in this Section.
2. Method of attaching roof accessories to roof or building structure.
3. Other roof-mounted items including mechanical and electrical equipment, ductwork, piping, and conduit.
4. Required clearances.
07 8400 Thermal &
Moisture Protection Firestopping Poduct Data
Silicone Elastomeric Firestopping: Single component silicone elastomeric compound and compatible silicone sealant
07 8400 Thermal &
Moisture Protection Firestopping Poduct Data Foam Firestopping Compounds: Single component foam compound
07 8400 Thermal &
Moisture Protection Firestopping Poduct Data
Formulated Firestopping Compound of Incombustible Fibers:
Formulated compound mixed with incombustible non-asbestos fibers
07 8400 Thermal &
Moisture Protection Firestopping Poduct Data
Fiber Stuffing and Sealant Firestopping: Composite of mineral or ceramic fiber stuffing insulation with silicone elastomer for smoke stopping
07 8400 Thermal &
Moisture Protection Firestopping Poduct Data
Intumescent Firestopping: Intumescent putty compound which expands on exposure to surface heat gain
07 8400 Thermal &
Moisture Protection Firestopping Poduct Data Firestop Pillows: Formed mineral fiber pillows
07 8400 Thermal &
Moisture Protection Firestopping Schedule
Submit schedule of opening locations and sizes, penetrating items, and required listed design numbers to seal openings to maintain fire resistance rating of adjacent assembly
07 8400 Thermal &
Moisture Protection Firestopping Manufacturer's Installation Instructions Submit preparation and installation instructions
07 8400 Thermal &
Moisture Protection Firestopping Manufacturer's Certificate
Certify products meet or exceed specified requirements and applicable code requirements
07 9000 Thermal &
Moisture Protection Joint Protection Product Data
Submit manufacturer information indicating sealant chemical characteristics, performance criteria, substrate preparation, limitations, and color availability
07 9000 Thermal &
Moisture Protection Joint Protection Samples
Submit manufacturer information indicating sealant chemical characteristics, performance criteria, substrate preparation, limitations, and color availability
07 9000 Thermal &
Moisture Protection Joint Protection Manufacturer Instructions
Submit special procedures, surface preparation requirements, and perimeter conditions requiring special attention
08 1213 Openings Standard Hollow Metal Frames Shop Drawings Indicate frame elevations, reinforcement, anchor types and spacing, location of cut-outs for hardware, and finish
08 1213 Openings Standard Hollow Metal Frames Product Data Submit frame configuration and finishes
08 1313 Openings Standard Hollow Metal Doors Shop Drawings Indicate door elevations, internal reinforcement, closure method, and cut-outs for glazing and finishes
08 1313 Openings Standard Hollow Metal Doors Product Data Submit door configurations, location of cut-outs for hardware reinforcement.
08 1313 Openings Standard Hollow Metal Doors Samples Submit two samples of door face metal, 12x12 inch in size illustrating shop finish colors and surface texture
08 3323 Openings Overhead coiling doors Product Data Submit general construction details, component connections, wiring diagrams
08 3323 Openings Overhead coiling doors Shop Drawings
Indicate relevant dimensioning, anchorage methods, hardware locations, and installation details for applicable supporting wall construction
08 3323 Openings Overhead coiling doors Samples Submit sample of shutter slats, six inches in length, illustrating shape, color, and finish texture
08 3323 Openings Overhead coiling doors Manufacturer's Certificate Certify Products meet or exceed specified requirements
08 3323 Openings Overhead coiling doors Manufacturer Instructions Submit special procedures, surface preparation requirements, and perimeter conditions requiring special attention
08 7100 Openings Door Hardware Shop Drawings
Indicate locations and mounting heights of each type of hardware, schedules, catalog cuts, electrical characteristics and connection requirements.
08 7100 Openings Door Hardware Shop Drawings Submit manufacturer's parts lists, and templates
08 7100 Openings Door Hardware Shop Drawings Submit proposed keying schedule
08 7100 Openings Door Hardware Manufacturer's Installation Instructions Submit special procedures, and perimeter conditions requiring special attention
08 8000 Openings Glazing Shop Drawings Indicate sizes, layout, thicknesses, and loading conditions for glass.
08 8000 Openings Glazing Product Data
1. Glass: Provide structural, physical, and thermal and solar optical performance characteristics, size limitations, special handling or installation requirements.
2. Glazing Sealants, Compounds and Accessories: Provide chemical, functional, and environmental characteristics, limitations, special application requirements. Identify available colors where exposed.
08 8000 Openings Glazing Design Data Submit design calculations for glass thicknesses.
08 8000 Openings Glazing Samples Glass: Submit sample 8x8 inch in size, illustrating glass units, coloration and design.
08 8000 Openings Glazing Manufacturer's Certificate Certify sealed insulating glass, meets or exceeds specified requirements
08 8716 Openings Safety and security window film Product Data
1. Manufacturer's Data Sheets.
2. Preparation instructions and recommendations.
3. Storage and handling requirements and recommendations.
4. Installation methods.
08 8716 Openings Safety and security window film Verification Samples For each film specified, two samples representing actual film color and pattern
09 2116 Finishes Gypsum Board Assemblies Shop Drawings
Shop Drawings:
1. Indicate special details associated with acoustic seals.
2. Indicate installation details required for seismic design loads.
09 2116 Finishes Gypsum Board Assemblies Product Data Submit data on metal framing, gypsum board, joint tape and acoustic accessories.
09 3000 Finishes Tiling Shop Drawings
Indicate tile layout, perimeter conditions, junctions with dissimilar materials, control and expansion joints, ceramic accessories, and setting details
09 3000 Finishes Tiling Product Submit instructions for using grouts and adhesives.
09 3000 Finishes Tiling Samples Submit mounted tile and grout on two 12” x 18” inch in size illustrating pattern, color variations, and grout joint size variations
09 3000 Finishes Tiling Manufacturer's Certificate Certify Products meet or exceed specified requirements
09 5113 Finishes Acoustical Panel Ceilings Product Data Suspended acoustical ceilings
09 5113 Finishes Acoustical Panel Ceilings Product Data ACT - 1 Acoustic Panels
09 5113 Finishes Acoustical Panel Ceilings Product Data ACT - 2 Acoustic Panels
09 5113 Finishes Acoustical Panel Ceilings Product Data Grid 1 (standard)
09 5113 Finishes Acoustical Panel Ceilings Product Data Grid 2 (humid areas)
09 6500 Finishes Resilient Flooring Product Data
Submit data describing physical and performance characteristics;
including sizes, patterns and colors available; and installation instructions.
09 6500 Finishes Resilient Flooring Samples Submit manufacturer's complete set of color samples for initial selection
09 6500 Finishes Resilient Flooring Samples Submit two samples, 4x6 inch in size illustrating color and pattern for each resilient flooring product selected
09 6566 Finishes Resilient Athletic Flooring Product Data Provide current printed data sheets for all Products Supplied
09 6566 Finishes Resilient Athletic Flooring Samples
Provide samples, 6 inches x 6 inches, for verification of such characteristics as color and surface texture of each specified resilient athletic flooring product. Include line paint on sample provided
09 6566 Finishes Resilient Athletic Flooring Samples Provide samples of available paint colors for line painting selection and approval.
09 6566 Finishes Resilient Athletic Flooring Shop drawing As necessary, provide shop drawings prepared for project illustrating layouts, details, dimensions and other data.
09 6566 Finishes Resilient Athletic Flooring Manufacturers Information
1. Provide Manufacturer’s printed subfloor preparation guidelines.
2. Provide Manufacturer’s printed installation guidelines for Products
Supplied.
09 6813 Finishes Tile Carpeting Product Data
Submit data on specified products, describing physical and performance characteristics; sizes, patterns, colors available, and method of installation
09 6813 Finishes Tile Carpeting Samples
1. Submit sample board of all color options, approximately 3”x3” swags.
2. To verify color selection, submit one full-sized carpet tile and one
6”x6” piece for each carpet color selected, illustrating color and pattern design.
3. Submit two 6 inch long samples of each color of edge strip.
09 9000 Finishes Painting and Coating Product Data Submit manufacturer data on finishing products and special coatings
09 9000 Finishes Painting and Coating Product Data Include MPI - Approved Products Lists with proposed products highlighted
09 9000 Finishes Painting and Coating Product Data Submit manufacturer data on finishing products and special coatings
09 9000 Finishes Painting and Coating Samples
Submit two paper chip samples, 4 by 4 inches in size, illustrating range of colors and textures available for each surface finishing product as scheduled
09 9726 Finishes Cementitious coating Product Data Manufacturer’s current product data bulletin.
10 1100 Specialties Visual Display Product Data Visual Display Board
10 1100 Specialties Visual Display Shop Drawings Indicate wall elevations, dimensions, joint locations, and anchor details
10 1100 Specialties Visual Display Samples Submit two 4x4 inch in size illustrating materials and finish, color and texture of markerboard and tackboard with surfacing
10 1400 Specialties Signage Shop Drawings Indicate sign styles, lettering font, foreground and background colors, locations, overall dimensions of each sign
10 2113 Specialties Plastic Toilet Compartments Product Data Solid plastic toilet compartments
10 2113 Specialties Plastic Toilet Compartments Product Data Pilaster Shoe
10 2113 Specialties Plastic Toilet Compartments Product Data Head Rails
10 2113 Specialties Plastic Toilet Compartments Product Data Brackets
10 2113 Specialties Plastic Toilet Compartments Shop Drawings Indicate partition plan, elevation views, dimensions, details of wall floor and ceiling supports, door swings
10 2113 Specialties Plastic Toilet Compartments Samples Submit two compartment samples, 4 by 4 inch in size, illustrating panel finish, color, and texture
10 2113 Specialties Plastic Toilet Compartments Manufacturer's Instructions including special procedures and special conditions
10 2213 Specialties Mesh Partitions Product Data Include construction details, material description, dimensions of individual components and profiles, and finishes for wire mesh items
10 2213 Specialties Mesh Partitions Shop Drawings Include plans, elevations, sections, details, and attachments to other work
10 2800 Specialties Toilet, Bath, and Laundry Accessories Product Data Mirrors
10 2800 Specialties Toilet, Bath, and Laundry Accessories Product Data Shower Curtain Rod
10 2800 Specialties Toilet, Bath, and Laundry Accessories Product Data Shower Curtain
10 2800 Specialties Toilet, Bath, and Laundry Accessories Product Data Clothes Hook
10 2800 Specialties Toilet, Bath, and Laundry Accessories Product Data Pedistal bench
10 2800 Specialties Toilet, Bath, and Laundry Accessories Manufacturer's Instructions Installation procedures, conditions requiring special attention.
10 4400 Specialties Fire Protection Specialties Product Data Submit extinguisher classifications, operational features, color and finish, anchorage details.
10 4400 Specialties Fire Protection Specialties Shop Drawings Indicate cabinet physical dimensions and rough in measurements for recessed cabinets.
10 4400 Specialties Fire Protection Specialties Manufacturer's Instructions Submit special criteria and wall opening coordination requirements.
10 5113 Specialties Metal Locker Shop Drawings Indicate locker plan layout, numbering plan, and key codes.
10 5113 Specialties Metal Locker Product Data Submit data on locker types, available colors, sizes and accessories.
10 5113 Specialties Metal Locker Samples Submit 3 x 6 inch sample of each color selected; applied to specified base metal.
10 5113 Specialties Metal Locker Manufacturer's Installation Instructions Submit installation template and attachment devices.
11 4000 Equipment Foodservice Equipment Shop Drawings
1. Indicate in large scale detail, fabricated equipment showing construction methods, type and gage of metal, hardware and fittings, plan, front elevation, minimum of one cross-section, and utility requirements as to types and sizes and locations.
2. Illustrate complicated parts of typical items in cut-away perspective.
3. For control systems, indicate service connections, characteristics, and wiring diagrams.
11 4000 Equipment Foodservice Equipment Product Data Submit data on appliances; indicate configuration, sizes, materials, finishes, locations, and utility connections and locations.
11 4000 Equipment Foodservice Equipment Manufacturer's Installation Instructions Submit special procedures and perimeter conditions requiring special attention.
11 4000 Equipment Foodservice Equipment Manufacturer's Certificate Certify Products meet or exceed UL specified requirements.
12 2413 Furnishings Roller Shades Product Data
1. Manufacturer's data sheets on each product to be used.
2. Include styles, material descriptions, construction details, dimensions of individual components and profiles, features, finishes, and operating instructions for window treatments.
3. Preparation instructions and recommendations.
4. Storage and handling requirements and recommendations.
5. Mounting details and installation methods.
12 2413 Furnishings Roller Shades Samples for selection: For each type of roller shade:
1. Shade Material: Mark inside face of material if applicable.
a. Size: Not less than 4 inches square.
b. Size: Not less than 6 inches square.
2. Roller Shade: Full-size operating unit, not less than 16 inches wide by 36 inches long for each type of roller shade indicated.
3. Installation Accessories: Full-size unit, not less than 6 inches long.
12 2413 Furnishings Roller Shades Verification Samples For each color and texture specified, submit 2 sets of samples representing actual finishes for aluminum slats at 6 inches long.
12 2413 Furnishings Roller Shades Shop Drawings Show fabrication and installation details for window treatments.
Include relationship with adjacent construction.
12 2413 Furnishings Roller Shades Window treatments Schedule Install on all existing windows excluding Drill Hall and Maintenance
Shop (noted on drawings as “Existing Building – No Work in This Area”)
12 2413 Furnishings Roller Shades Qualification Data Qualifications for Installer.
12 2413 Furnishings Roller Shades Product Test Reports For each type of fabric band material, for tests performed by manufacturer and witnessed by a qualified testing agency.
12 2413 Furnishings Roller Shades Product Test Reports For each type of fabric band material, for tests performed by a qualified testing agency.
12 2413 Furnishings Roller Shades Maintenance Data For window treatments to include in maintenance manuals.
12 2413 Furnishings Roller Shades Sample Warrenty Provide a sample warrenty
12 3530 Furnishings Residentail casework Shop Drawings Indicate casework locations, large scale plans, elevations, rough-in and anchor placement dimensions and tolerances, and clearances required.
12 3530 Furnishings Residentail casework Product Data Submit component dimensions, configurations, construction details and joint details.
12 3530 Furnishings Residentail casework Samples Submit two samples, minimum size 3 x 6 inches of each color of finish and two samples of each type of hardware.
12 3661 Furnishings Solid Surfacing Fabrications Product Data Submit data on specified component product
12 3661 Furnishings Solid Surfacing Fabrications Shop Drawings
Indicate dimensions, thicknesses, required clearances, tolerances, materials, colors, finishes, fabrication details, field jointing, adjacent construction, methods of support, integration of components, and anchorages.
12 3661 Furnishings Solid Surfacing Fabrications Samples Submit two samples representative of window sill, 2 by 2 inch in size, illustrating color, texture, and finish
22 0516 Plumbing Expansion Fitting and Loops for Pumbing Piping Product Data
1. Flexible Pipe Connectors: Indicate maximum temperature and pressure rating, face-to-face length, live length, hose wall thickness, hose convolutions per foot and per assembly, fundamental frequency of assembly, braid structure, and total number of wires in braid.
2. Expansion Joints: Indicate maximum temperature and pressure rating, and maximum expansion compensation.
22 0529 Plumbing Hangers and Supports for Plumbing Piping and
Equipment Product Data
Hangers and Supports: Submit manufacturers catalog data including load capacity
22 0529 Plumbing Hangers and Supports for Plumbing Piping and
Equipment Product Data
Firestopping: Submit data on product characteristics, performance and limitation criteria
22 0553 Plumbing Identification for Plumbing Piping and Equipment Product Data Submit manufacturers catalog literature for each product required.
22 0553 Plumbing Identification for Plumbing Piping and Equipment Shop Drawings
Submit list of wording, symbols, letter size, and color coding for mechanical identification and valve chart and schedule, including valve tag number, location, function, and valve manufacturer's name and model number
22 0700 Plumbing Plumbing Insulation Product Data Submit product description, thermal characteristics and list of materials and thickness for each service, and location.
22 0700 Plumbing Plumbing Insulation Manufacturer's Installation Instructions Submit manufacturers published literature indicating proper installation procedures.
22 0700 Plumbing Plumbing Insulation Manufacturer's Certificate Certify products meet or exceed specified requirements
22 1100 Plumbing Facility Water Distribution Product Data Piping: Submit data on pipe materials, fittings, and accessories. Submit manufacturer's catalog information
22 1300 Plumbing Facility Sanitary Sewerage Product Data Piping: Submit data on pipe materials, fittings, and accessories. Submit manufacturers catalog information.
22 1300 Plumbing Facility Sanitary Sewerage Manufacturer's Certificate Certify products meet or exceed specified requirements.
22 1400 Plumbing Facility Storm Drainage Product Data Piping: Submit data on pipe materials, fittings, and accessories. Submit manufacturers catalog information
22 1400 Plumbing Facility Storm Drainage Product Data Valves: Submit manufacturers catalog information with valve data and ratings for each service
22 4000 Plumbing Plumbing Fixtures Product Data Submit catalog illustrations of fixtures, sizes, rough-in dimensions, utility sizes, trim, and finishes
22 4000 Plumbing Plumbing Fixtures Manufacturer's Installation Instructions Submit installation methods and procedures.
23 0529 HVAC Hangers and Supports for HVAC Piping and Equipment Product Data
1. Hangers and Supports: Submit manufacturers catalog data including load capacity.
2. Firestopping: Submit data on product characteristics, performance and limitation criteria.
23 0529 HVAC Hangers and Supports for HVAC Piping and Equipment Design Data
Indicate load carrying capacity of trapeze, multiple pipe, and riser support hangers. Indicate calculations used to determine load carrying capacity of trapeze, multiple pipe, and riser support hangers.
23 0529 HVAC Hangers and Supports for HVAC Piping and Equipment Manufacturer's Installation Instructions Hangers and Supports: Submit special procedures and assembly of components.
23 0529 HVAC Hangers and Supports for HVAC Piping and Equipment Manufacturer's Certificate Certify products meet or exceed specified requirements.
23 0548 HVAC
Vibration and seismic controls for HVAC piping and equipment Manufacturer's Installation Instructions
Submit special procedures and setting dimensions. Indicate installation requirements maintaining integrity of sound isolation.
23 0553 HVAC Identification for HVAC Piping and Equipment Shop Drawings
Submit list of wording, symbols, letter size, and color coding for mechanical identification and valve chart and schedule, including valve tag number, location, function, and valve manufacturer's name and model number
23 0700 HVAC HVAC Insulation Product Data Submit product description, thermal characteristics and list of materials and thickness for each service, and location
23 0700 HVAC HVAC Insulation Manufacturer's Installation Instructions Submit manufacturers published literature indicating proper installation procedures.
23 0700 HVAC HVAC Insulation Manufacturer's Certificate Certify products meet or exceed specified requirements.
23 0900 HVAC Instumentation and control for HVAC Shop Drawings
Indicate operating data, system drawings, wiring diagrams, and written detailed operational description of sequences. Coordinate submittals with information requested in Section 23 09 93.
23 0900 HVAC Instumentation and control for HVAC Product Data Submit description and engineering data for each control system component. Include sizing as required.
23 0900 HVAC Instumentation and control for HVAC Manufacturer's Installation Instructions Submit installation requirements for each control component
23 0900 HVAC Instumentation and control for HVAC Manufacturer's Certificate Certify products meet or exceed specified requirements
23 0923 HVAC ACC Delta direct digital control system for HVAC Shop Drawings
Indicate the following:
1. Trunk cable schematic showing programmable control-unit locations and trunk data conductors.
2. Connected data points, including connected control unit and input device.
3. List of system graphics of monitored systems, data (connected and calculated) point addresses, and operator notations.
4. System configuration with new peripheral devices, diagrams, modems, routers, and interconnections.
5. Description and sequence of operation for operating, user, and application software 23 0923 HVAC ACC Delta direct digital control system for HVAC Product Data Submit data for each system component and software module.
23 0923 HVAC ACC Delta direct digital control system for HVAC Manufacturer's Installation Instructions Submit installation instruction for each control system component
23 1123 HVAC Facility natural-gas piping Product Data
1. Piping: Submit data on pipe materials, fittings, and accessories.
Submit manufacturers catalog information.
2. Piping Specialties: Submit manufacturers catalog information including capacity, rough-in requirements, and service sizes for the following:
a. Strainers.
b. Natural gas pressure regulators.
c. Natural gas pressure relief valves.
23 1123 HVAC Facility natural-gas piping Welders Certificates Certify welders employed on the Work, verifying AWS qualification within previous 12 months.
23 2213 HVAC Steam and condensate heating piping Product Data
1. Piping: Submit data on pipe materials, fittings, and accessories.
Submit manufacturers catalog information.
2. Valves: Submit manufacturers catalog information with valve data and ratings for each service.
3. Hangers and Supports: Submit manufacturers catalog information including load capacity.
23 3300 HVAC Air Duct Accessories Product Data Dynamic Rated fire damper
23 3700 HVAC Air outlets and Inlets Product Data Rectangular ceiling difusers
23 3700 HVAC Air outlets and Inlets Product Data Ceiling grid core exhaust and return registers/grilles
23 3700 HVAC Air outlets and Inlets Product Data Wall supply registers/grilles
23 3700 HVAC Air outlets and Inlets Product Data Wall exhaust and return registers/grilles
23 7200 HVAC Air-to-air Energy Recovery Equipment Shop Drawings