5. CAFB Labeling Standards 2011.pptx

PPTX presentation 86 KB Posted

Attached to
Building 60 Renovation Federal contract opportunity
Solicitation number
FA485521B0002
Issued by
Department of the Air Force Special Operations Command

About this file

This PowerPoint presentation outlines standards for labeling telecommunications cables and outlets at federal facilities. It specifies the naming conventions and numbering schemes to be used for identifying patch panels, telecommunications racks, outlet ports, copper and fiber optic cables, termination locations, and outside plant cables. Standards are provided for labeling patch panels, racks, outlet ports, cable identification, fiber strand counts, premises and outside plant cables. Jacks are to be arranged clockwise and numbered around each room. Cable labeling adheres to the TIA/EIA 606 telecommunications standard.

The related federal contract solicitation seeks proposals to renovate Building 60 at an unspecified Air Force Special Operations Command facility. Interested offerors should attend the mandatory site visit on 9 July at 1:00PM MDT to learn more about the requirement. The solicitation and attached documents provide additional details on the scope of work.

View the file

Other files for this federal contract opportunity

Other files attached to Building 60 Renovation, newest first.
File Type Posted
Site Visit Sign-in Sheet.pdf PDF
Questions and Answers v2.docx DOCX document
Appendix A - Drawings Rev1.pdf PDF
Asbestos Survey_B60_30March21_Signed.pdf PDF
SOW 21-0005 Renovate B60 Rev. 1.docx DOCX document
Building 60 Site Visit Questions_answers.docx DOCX document
4. CAFB Hardware Specifications Guideline- 2011.pdf PDF
Appendix C - Specifications Renovate B60.pdf PDF
1. Contractor Base Briefing Pamphlet (March 2016).pdf PDF
7. As-Built Submittal Guidelines-2014.pdf PDF
Attachment 3 SOMS CZQZ 21-0005 Renovate B60.pdf PDF
Solicitation - FA485521B0002.pdf PDF
Attachment 1 SOW 21-0005 Renovate B60.pdf PDF
Appendix A - Drawings.pdf PDF
2. CAFB Architectural Compatibilty Guide-2013.pdf PDF
1. Draft DD1354 Renovate B60.pdf PDF
5. CAFB IMT Form 3624 Facilities Outage Request.pdf PDF
6. AF Form 3000 Submittal Cover Sheet.pdf PDF
Attachment 2 Wage Determination.pdf PDF
3. CANNONAFBI32 201 Fire Protection-2012.pdf PDF
6. AEC CAD Standards 6.1 Aug 2019.pdf PDF
8. ANSI D (plan sizing).pdf PDF
2. AF Form 3064 Schedule.xlsx XLSX spreadsheet
3. AF Form 3065 Progress Report.xlsx XLSX spreadsheet
4. AF Form 103 Work Clearance Request.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PATCH PANEL

TELECOMMUNICATIONS RACK

PORT ON PANEL

R1 -A -1

HORIZONTAL CABLES

TR1 - TR2

100 PR 24 AWG

CA01 301 - 400

CABLE NUMBER

TERMINATED COUNT

TERMINATION LOCATIONS

CABLE SIZE

TR1 - TR2

12 FIBER MM

FO 01 1-12

TERMINATION LOCATIONS

FIBER CABLE NUMBER

SINGLE OR

CABLE GUAGE

FIBER TERMINATIONS

BUILDING BACKBONE CABLES

MMAC - 1 - X

R1 -A - X

TELECOMMUNICATIONS RACK

JACK NUMBER

DEVICE

CARD NUMBER

PORT NUMBER

PATCH CABLES

MULTIMODE

WARNING

IF THIS CLAMP OR CABLE

IS LOOSE OR MUST BE

REMOVED PLEASE CALL THE

BUILDING TELECOMMUNICATIONS

MANAGER

TMGB

TR1

ER1

TELECOMMUNICATIONS

MAIN GROUNDING

BUSBAR

TELECOMMUNICATIONS

ROOM

EQUIPMENT ROOM

GROUNDING

TBB

TGB

TGB

TBB

Premises Wiring - 27 SOCS/SCOS Cable labeling program 1/29/09 Questions can be directed to 575-784-2710

OUTLET PORT

R1-A 1 2

PATCH PANEL LETTER

(Patch Panels will be lettered in order starting with A)

TELECOMMUNICATIONS RACK NUMBER

(Telecommunications Racks will be numbered numerically, starting with 1, i.e. R1, R2)

3 R1-A 4

JACK LOCATION LABELS

1 2

5 6

Jacks shall be arranged and labeled according to their location in a room. They shall be arranged clockwise in ascending order around the room while standing in the doorway looking into the room. Floor jack number arrangement should work in clockwise order, looking out the TR doorway. The 27 SOCS labeling scheme adheres to the requirements outlined in the TIA/EIA 606 telecommunication standard.

A

NUMBER

OUTLET PORT LOCATION

SINGLE GANG

DOUBLE GANG

R1-A 3 4 R1-A 3 4 R1-A 7 8

OUTLET PORT

(Ports will be numbered according to port number on patch panel. Ports will be numbered consecutively per quad face plate.)

1 R1-A 2

100 PR 24 AWG

CA01 301 - 400

CABLE NUMBER

TERMINATED COUNT

FO Bxx- Bxx 1-12 MM or SM

Fiber Optic Cable I.D.

FIBER CABLE NUMBER

SINGLE OR

CABLE GUAGE

FIBER Cable Strand Count

OUTSIDE PLANT CABLES

MULTIMODE

Copper Cable I.D.

CA-01, 301-400

P1-24PF

Example

FO B10-B355

1-12, SM

Example

Premises Wiring - 1 CS/SCXI Cable labeling program 5/29/01 Questions can be directed to 757-764-7911

CA-100, 1-50

P1-24PF

50 PR 24 AWG

CA100 1 - 25

CA-100, 1-50

P1-24PF

50 PR 24 AWG

CA100 1 - 25

CA-01, 301-400

P1-24PF

50 PR 24 AWG

PR 24 AWG

File details come from the government source that posted it. Updated .