5-ATTACHMENT 4-2 ERP PERMIT.pdf

PDF 6 MB Posted

Attached to
Cross Bar Ranch Wellfield Water Transmission Main - Utility Conflict (Project 07153)
Solicitation number
2026017
Issued by
Hillsborough County, Florida

About this file

This is an Environmental Resource Permit (ERP) issued by the Florida Department of Environmental Protection (FDEP) Southwest District to Tampa Bay Water for the Cross Ranch Water Transmission Main project. The permit authorizes the relocation of approximately 500 linear feet of an existing 60-inch diameter raw water transmission line under State Road 52 in Land O' Lakes, Florida. The project involves micro-tunneling under the roadway and roadside swale, with the remaining pipeline constructed via open cut trenching within uplands. No impacts to wetlands or surface waters are proposed. The permit was issued on December 19, 2025, with a construction phase expiration date of December 18, 2030. The permittee is Tampa Bay Water, with Wade Trim serving as the authorized agent. Prior to construction commencement, the permittee must submit a fully executed Construction Commencement Notice (Form 62-330.350(1)) to the FDEP at least 48 hours in advance, indicating expected start and completion dates.

The permit contains specific and general conditions that must be satisfied throughout the construction and operation phases. Key requirements include implementation of erosion and sediment control best management practices prior to construction commencement, daily inspection and maintenance of erosion control devices, protection of wetlands and surface waters from siltation, and stabilization of disturbed areas within 48 hours of final grading. For horizontal directional drilling activities, the permittee must follow an approved Frac-Out Contingency Plan, conduct HDD activities only during daylight hours, and perform visual inspections within 2 hours of punch-out and back-reams, with a written report submitted within 7 days. Within 30 days of completion of construction, the permittee must submit as-built drawings signed and sealed by a Florida registered professional, photographs of the completed structure, and Form 62-330.310(1) to request conversion to the operation phase. A separate U.S. Army Corps of Engineers permit authorization is required, and the project must comply with all applicable local, state, and federal regulations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FLORIDA DEPARTMENT OF

Environmental Protection

Southwest District

13051 North Telecom Parkway #101 Temple Terrace, Florida 33637-0926

Ron DeSantis Governor

Jay Collins

Lt. Governor

Alexis A. Lambert Secretary

December 19, 2025

Tampa Bay Water c/o Charles Carden 2575 Enterprise Road Clearwater, Florida, 33763 Permitting@Tampabaywater.org

Dear Charles Carden:

Enclosed is the Environmental Resource Permit, DEP Project No. 51-0459255-002-EI, issued pursuant to Part IV of Chapter 373, Florida Statutes, and Title 62, Florida Administrative Code.

Appeal rights for you and for any affected third party are described in the text of the permit along with conditions that must be met when authorized activities are undertaken.

You, as the applicant, are responsible for all aspects of permit compliance. You should therefore review this permit document carefully to ensure compliance with the general conditions and specific conditions contained herein.

Please be aware of permit General Condition number 4, which states, “At least 48 hours prior to beginning the authorized activities, the permittee shall submit to the Agency a fully executed Form 62-330.350(1), ‘Construction Commencement Notice.’”

If you have any questions about this document, please contact me at Jessica.t.hamilton@floridadep.gov or at 813-470-5956. Thank you for your participation in the permit process and in managing the natural resources of the State of Florida.

Sincerely, Jessica Hamilton Environmental Specialist III Permitting and Waste Cleanup Program

Enclosure: Environmental Resource Permit with Attachments (42 pages)

Temple Terrace, Florida 33637-0926

Permittee/Authorized Entity:

Tampa Bay Water c/o Charles Carden 2575 Enterprise Road

Clearwater, Florida, 33763

Cross Ranch Water Transmission

Authorized Agent:

Wade Trim c/o Nita Sharma 201 North Franklin Street, Suite 1350

Tampa, Florida, 33602

Individual Environmental Resource Permit

State-owned Submerged Lands Authorization – Not Applicable

U.S. Army Corps of Engineers Authorization – Separate Corps Authorization Required

Pasco County

Permit No.: 51-0459255-002-EI

Permit Issuance Date: 12/19/2025 Permit Construction Phase Expiration Date: 12/18/2030

Temple Terrace, Florida 33637-0926

Environmental Resource Permit

Permittee: Tampa Bay Water c/o Charles Carden Permit No: 51-0459255-002-EI

PROJECT LOCATION

The activities authorized by this permit are located within the Right-Of-Way on State Road 52, Land O’ Lakes, Florida 34637, Parcel ID: 07-25-19-0000-29900-0000, in Section 7, Township 25 South, Range 19 East in Pasco County, at latitude 28° 19’ 18.62” and longitude -82° 26’ 39.83”.

PROJECT DESCRIPTION

The permittee is authorized to relocate approximately 500 linear feet of an existing 60-inch diameter raw water transmission line. Those activities include the micro tunneling under the roadway and roadside swale, and the remaining pipeline will be constructed within uplands by open cut trenching.

No impacts to wetlands or surface waters are proposed. Authorized activities are depicted on the attached exhibits.

AUTHORIZATIONS

Cross Ranch Water Transmission

Environmental Resource Permit The Department has determined that the activity qualifies for an Environmental Resource Permit.

Therefore, the Environmental Resource Permit is hereby granted, pursuant to Part IV of Chapter 373, Florida Statutes (F.S.), and Chapter 62-330, Florida Administrative Code (F.A.C.).

Sovereignty Submerged Lands Authorization As staff to the Board of Trustees of the Internal Improvement Trust Fund (Board of Trustees), the Department has determined the activity is not on submerged lands owned by the State of Florida.

Therefore, your project is not subject to the requirements of Chapter 253, F.S., or Rule 18-21, F.A.C.

Federal Authorization Your proposed activity as outlined on your application and attached drawings does not qualify for Federal authorization pursuant to the State Programmatic General Permit and a SEPARATE permit or authorization shall be required from the Corps. You must apply separately to the Corps using the Application for Department of the Army Permit (ENG 4345) or alternative as allowed by Corps regulations. More information on Corps permitting may be found online in the Jacksonville District Regulatory Division Sourcebook:

Permittee: Tampa Bay Water c/o Charles Carden Permit Expiration: 12/18/2030

(https://www.saj.usace.army.mil/Missions/Regulatory/Source-Book/).

Authority for review - an agreement with the USACOE entitled “Coordination Agreement Between the U. S. Army Corps of Engineers (Jacksonville District) and the Florida Department of Environmental Protection (or Duly Authorized Designee), State Programmatic General Permit”, Section 10 of the Rivers and Harbor Act of 1899, and Section 404 of the Clean Water Act.

Coastal Zone Management Consistent Issuance of this authorization also constitutes a finding of consistency with Florida's Coastal Zone Management Program, as required by Section 307 of the Coastal Zone Management Act.

Water Quality Certification Granted This permit also constitutes a grant of water quality certification under Section 401 of the Clean Water Act, 33 U.S.C. Section 1341. Pursuant to Rule 62-330.062, F.A.C. issuance of the individual or conceptual approval permit under this chapter shall constitute certification of compliance with water quality standards.

Other Authorizations You are advised that authorizations or permits for this activity may be required by other federal, state, regional, or local entities including but not limited to local governments or municipalities.

This permit does not relieve you from the requirements to obtain all other required permits or authorizations.

The activity described may be conducted only in accordance with the terms, conditions and attachments contained in this document. Issuance and granting of the permit and authorizations herein do not infer, nor guarantee, nor imply that future permits, authorizations, or modifications will be granted by the Department.

PERMIT CONDITIONS

The activities described must be conducted in accordance with:

The Specific Conditions The General Conditions The limits, conditions and locations of work shown in the attached drawings The term limits of this authorization

You are advised to read and understand these conditions and drawings prior to beginning the authorized activities, and to ensure the work is conducted in conformance with all the terms, conditions, and drawings herein. If you are using a contractor, the contractor also should read and understand these conditions and drawings prior to beginning any activity. Failure to comply with these conditions, including any mitigation requirements, shall be grounds for the Department to revoke the permit and authorization and to take appropriate enforcement action. Operation of the facility is not authorized except when determined to be in conformance with all applicable rules and this permit authorization, as described.

SPECIFIC CONDITIONS

1. Submittals required herein (e.g., progress reports, as-built drawings, etc.) shall include the permittee's name and permit number 51-0459255-002-EI and shall be directed by e-mail to SW_ERP_CAP@floridadep.gov with a subject line of “Compliance: permit number 51- 0459255-002-EI”, or by mail to:

Department of Environmental Protection

ATTN: ERP Compliance Assurance 13051 North Telecom Parkway, Suite 101 Temple Terrace, FL 33637-0926

2. The structure/work authorized by this permit shall not be placed/conducted on any property, other than that owned by the permittee, without the prior written approval of that property owner.

3. In the event the permittee files for bankruptcy prior to completion of work permitted and required by this permit, the permittee must notify the Department within 30 days of filing.

The notification shall identify the bankruptcy court and case number and shall include a copy of the bankruptcy petition.

SPECIFIC CONDITIONS – PRIOR TO ANY CONSTRUCTION

4. Best management practices for erosion control shall be implemented prior to construction commencement and shall be maintained at all times during construction to prevent siltation and turbid discharges in excess of State water quality standards (>29 NTU’s above background, pursuant to Rule 62-302, F.A.C. Methods may include but are not limited to the use of staked hay bales, staked filter cloth, sodding, seeding, staged construction and the installation of turbidity screens around the immediate project site.

SPECIFIC CONDITIONS – CONSTRUCTION ACTIVITIES

5. Wetland areas or waterbodies that are outside the specific limits of construction authorized by this permit, must be protected from erosion, sedimentation, siltation, scouring, excess turbidity, and/or dewatering. There shall be no discharge in violation of the water quality standards in Chapter 62-302, F.A.C. Turbidity/erosion controls shall be installed prior to clearing, excavation or placement of fill material, shall be maintained until construction is completed, disturbed areas are stabilized, and turbidity levels have fallen to less than 29 NTU's above background. The turbidity and erosion control devices shall be removed within 14 days once these conditions are met.

6. Areas of exposed soils shall be isolated from wetlands or other surface waters to prevent erosion and deposition of these soils into wetlands or other surface waters during construction and operation of permitted activities.

7. Side slopes, exposed and/or disturbed land surfaces shall be stabilized with sod, seed or mulch within 48 hours following completion of final grades at the project site to prevent erosion, sedimentation, siltation or scouring.

8. The permittee shall be responsible for ensuring erosion control devices/procedures are inspected and maintained daily during all phases of construction authorized by this permit until areas disturbed during construction are sufficiently stabilized to prevent erosion, siltation, and turbid discharges.

9. Staked filter cloth shall be positioned at the edge of the permitted fill slopes adjacent to wetlands to prevent turbid run-off and erosion.

10. There shall be no discharge of construction debris into the waters of the state as conditioned by this permit enforceable under the Florida Litter Law 403.413, F.S., by all law enforcement officers.

11. This permit does not authorize the removal of any vegetation within the jurisdictional area.

No dredging, filling, or other construction activity, including the removal of tree stumps and/or vegetative root masses, shall be conducted within the wetlands other than that performed within the specifically authorized work corridor.

12. Unauthorized impacts to wetlands as a result of the authorized construction shall be reported to the Department within 24 hours.

13. Storage or stockpiling of tools and materials (i.e., lumber, pilings, debris) within wetlands or other surface waters is prohibited.

SPECIFIC CONDITIONS FOR LISTED SPECIES

14. This permit does not authorize the permittee to cause any adverse impact to or “take” of state listed species and other regulated species of fish and wildlife. Compliance with state laws regulating the take of fish and wildlife is the responsibility of the owner or permittee associated with this project. Please refer to Chapter 68A-27 of the Florida Administrative Code for definitions of “take” and a list of fish and wildlife species. If listed species are observed onsite, Florida Fish and Wildlife Conservation Commission (FWC) staff are available to provide decision support information or assist in obtaining the appropriate FWC permits. Most marine endangered and threatened species are statutorily protected and a “take” permit cannot be issued. Requests for further information or review can be sent to ConservationPlanningServices@MyFWC.com.

15. If new information (e.g. listing of new species, new critical habitat, etc.) shows that the magnitude of impacts to federally listed species has the potential for adverse effects, the U.S. Fish and Wildlife Service (USFWS) will notify the Department. The Department will initiate coordination with the permittee and with the USFWS to determine what adverse impacts are likely and if additional minimization measures, reporting, or monitoring are required in order to be consistent with the Endangered Species Act, as deemed necessary by

USFWS.

16. The Permittee shall report any injured, sick, or dead federally or state listed animal(s) discovered onsite to the Florida Fish and Wildlife Conservation Commission Wildlife Alert number at 888-404-FWCC (3922).

SPECIFIC CONDITIONS – HORIZONTAL DIRECTIONAL DRILL

17. The hydraulic directional drill (HDD) bore pits and all staging shall be within uplands.

18. The permittee shall follow the approved Frac-Out Contingency Plan (attached).

19. All HDD activities shall take place during daylight hours only.

20. Within 2 hours of the HDD punch out and subsequent back-reams, the permittee shall perform a visual inspection of the submerged lands along the subaqueous portions of the HDD corridor to inspect for bentonite releases or frac-outs. Within 7 days of the HDD punch out and subsequent back-reams, the permittee shall submit a written summary report to the Department that includes the following information:

a. timeline of the outfall/pit installations

b. any complications encountered during outfall installations

c. details of any dye detection and subsequent bentonite clean-up operation

d. discussion of possible causes of bentonite discharges (frac-outs); and

e. suggestions for future frac-out prevention measures

21. If a frac-out occurs during the subaqueous crossing installation which results in adverse impacts wetlands, submerged or emergent vegetation, or other biological resources, restoration and mitigation shall be required to offset adverse impacts.

22. Within 30 days of each pit installation, the permittee shall fully restore the staging area to its original condition. Paved surfaces shall be repaired, and unpaved surface areas shall be replanted with appropriate non-nuisance native vegetation.

SPECIFIC CONDITIONS – CONSTRUCTION COMPLETION

The permittee shall comply with the following conditions prior to the transfer to operation phase of the facility. All documentation required below shall be included with the permittee’s request to transfer the project to the operation phase [Form No. 62-330.310(2), F.A.C.]

23. Within 30 days after completion of construction of the permitted or authorized activity, and prior to transfer to operation, the permittee shall submit photographs of the completed structure. The photographs shall show the size and dimensions of all existing structures and activities within the permitted project area. Constructed deviations may require a permit modification and/or easement.

24. The permittee shall submit one set of signed, dated and sealed as-built drawings to the Department via email at SW_ERP_CAP@floridadep.gov for review and approval within 30 days of completion of construction. (Please contact the Department for files that are too large to email for alternative means of submitting electronically.) The as-built drawings shall be based on the Department permitted construction drawings and any pertinent specific conditions, which should be revised to reflect changes made during construction. Both the original design and constructed elevations must be clearly shown. The plans must be clearly labeled as "as-built" or "record" drawings. Surveyed dimensions and elevations required shall be verified and signed, dated and sealed by a Florida registered professional. As-builts shall be submitted to the Department regardless of whether or not deviations are present. In addition, the permittee shall submit the “As- Built Certification and Request for Conversion to Operation Phase” form (Ch. 62- 330.310(1), F.A.C.); as required in General Condition #6.

The following information shall be verified on the as-built drawings from the engineering drawings signed and sealed by Nita Naik Sharma, P.E., No.79670 on June 12, 2025, and Glenn Willson No. 86800 on September 23, 2025:

Plan View/ Cross Section Name Drawing Number Tree Removal and Limits of Disturbance C-1 Plan C-2 Profile C-3 Condensed Profile D-2-D-3

GENERAL CONDITIONS FOR INDIVIDUAL PERMITS

The following general conditions are binding on all individual permits issued under this chapter, except where the conditions are not applicable to the authorized activity, or where the conditions must be modified to accommodate project-specific conditions.

1. All activities shall be implemented following the plans, specifications and performance criteria approved by this permit. Any deviations must be authorized in a permit modification in accordance with Rule 62-330.315, F.A.C. Any deviations that are not so authorized may subject the permittee to enforcement action and revocation of the permit under Chapter 373, F.S.

2. A complete copy of this permit shall be kept at the work site of the permitted activity during the construction phase and shall be available for review at the work site upon request by the Agency staff. The permittee shall require the contractor to review the complete permit prior to beginning construction.

3. Activities shall be conducted in a manner that does not cause or contribute to violations of state water quality standards. Performance-based erosion and sediment control best management practices shall be installed immediately prior to, and be maintained during and after construction as needed, to prevent adverse impacts to the water resources and adjacent lands. Such practices shall be in accordance with the State of Florida Erosion and Sediment Control Designer and Reviewer Manual (Florida Department of Environmental Protection and Florida Department of Transportation June 2007), and the Florida Stormwater Erosion and Sedimentation Control Inspector’s Manual (Florida Department of Environmental Protection, Nonpoint Source Management Section, Tallahassee, Florida, July 2008), which are both incorporated by reference in subparagraph 62-330.050(9)(b)5., F.A.C., unless a project-specific erosion and sediment control plan is approved or other water quality control measures are required as part of the permit.

4. At least 48 hours prior to beginning the authorized activities, the permittee shall submit to the Agency a fully executed Form 62-330.350(1), “Construction Commencement Notice,” (October 1, 2013), (http://www.flrules.org/Gateway/reference.asp?No=Ref-02505), incorporated by reference herein, indicating the expected start and completion dates. A copy of this form may be obtained from the Agency, as described in subsection 62-330.010(5), F.A.C., and shall be submitted electronically or by mail to the Agency. However, for activities involving more than one acre of construction that also require a NPDES stormwater construction general permit, submittal of the Notice of Intent to Use Generic Permit for Stormwater Discharge from Large and Small Construction Activities, DEP Form 62-621.300(4)(b), shall also serve as notice of commencement of construction under this chapter and, in such a case, submittal of Form 62-330.350(1) is not required.

5. Unless the permit is transferred under Rule 62-330.340, F.A.C., or transferred to an operating entity under Rule 62-330.310, F.A.C., the permittee is liable to comply with the plans, terms and conditions of the permit for the life of the project or activity.

6. Within 30 days after completing construction of the entire project, or any independent portion of the project, the permittee shall provide the following to the Agency, as applicable:

a. For an individual, private single-family residential dwelling unit, duplex, triplex, or quadruplex ‒ “Construction Completion and Inspection Certification for Activities Associated With a Private Single-Family Dwelling Unit” [Form 62-330.310(3)]; or

b. For all other activities ‒ “As-Built Certification and Request for Conversion to Operational

Phase” [Form 62-330.310(1)].

c. If available, an Agency website that fulfills this certification requirement may be used in lieu of the form.

7. If the final operation and maintenance entity is a third party:

a. Prior to sales of any lot or unit served by the activity and within one year of permit issuance, or within 30 days of as- built certification, whichever comes first, the permittee shall submit, as applicable, a copy of the operation and maintenance documents (see sections 12.3 thru 12.3.3 of Volume I) as filed with the Department of State, Division of

Corporations and a copy of any easement, plat, or deed restriction needed to operate or maintain the project, as recorded with the Clerk of the Court in the County in which the activity is located.

b. Within 30 days of submittal of the as- built certification, the permittee shall submit

“Request for Transfer of Environmental Resource Permit to the Perpetual Operation Entity” [Form 62-330.310(2)] to transfer the permit to the operation and maintenance entity, along with the documentation requested in the form. If available, an Agency website that fulfills this transfer requirement may be used in lieu of the form.

8. The permittee shall notify the Agency in writing of changes required by any other regulatory agency that require changes to the permitted activity, and any required modification of this permit must be obtained prior to implementing the changes.

9. This permit does not:

a. Convey to the permittee any property rights or privileges, or any other rights or privileges other than those specified herein or in Chapter 62-330, F.A.C.;

b. Convey to the permittee or create in the permittee any interest in real property;

c. Relieve the permittee from the need to obtain and comply with any other required federal, state, and local authorization, law, rule, or ordinance; or

d. Authorize any entrance upon or work on property that is not owned, held in easement, or controlled by the permittee.

10. Prior to conducting any activities on state-owned submerged lands or other lands of the state, title to which is vested in the Board of Trustees of the Internal Improvement Trust Fund, the permittee must receive all necessary approvals and authorizations under Chapters 253 and 258, F.S. Written authorization that requires formal execution by the Board of Trustees of the Internal Improvement Trust Fund shall not be considered received until it has been fully executed.

11. The permittee shall hold and save the Agency harmless from any and all damages, claims, or liabilities that may arise by reason of the construction, alteration, operation, maintenance, removal, abandonment or use of any project authorized by the permit.

12. The permittee shall notify the Agency in writing:

a. Immediately if any previously submitted information is discovered to be inaccurate; and

b. Within 30 days of any conveyance or division of ownership or control of the property or the system, other than conveyance via a long-term lease, and the new owner shall request transfer of the permit in accordance with Rule 62-330.340, F.A.C. This does not apply to the sale of lots or units in residential or commercial subdivisions or condominiums where the stormwater management system has been completed and converted to the operation phase.

13. Upon reasonable notice to the permittee, Agency staff with proper identification shall have permission to enter, inspect, sample and test the project or activities to ensure conformity with the plans and specifications authorized in the permit.

14. If prehistoric or historic artifacts, such as pottery or ceramics, projectile points, stone tools, dugout canoes, metal implements, historic building materials, or any other physical remains that could be associated with Native American, early European, or American settlement are encountered at any time within the project site area, the permitted project shall cease all activities involving subsurface disturbance in the vicinity of the discovery. The permittee or other designee shall contact the Florida Department of State, Division of Historical Resources, Compliance Review Section (DHR), at (850)245-6333, as well as the appropriate permitting agency office. Project activities shall not resume without verbal or written authorization from the Division of Historical Resources. If unmarked human remains are encountered, all work shall stop immediately and the proper authorities notified in accordance with section 872.05, F.S. For project activities subject to prior consultation with the DHR and as an alternative to the above requirements, the permittee may follow procedures for unanticipated discoveries as set forth within a cultural resources assessment survey determined complete and sufficient by DHR and included as a specific permit condition herein.

15. Any delineation of the extent of a wetland or other surface water submitted as part of the permit application, including plans or other supporting documentation, shall not be considered binding unless a specific condition of this permit or a formal determination under Rule 62-330.201, F.A.C., provides otherwise.

16. The permittee shall provide routine maintenance of all components of the stormwater management system to remove trapped sediments and debris. Removed materials shall be disposed of in a landfill or other uplands in a manner that does not require a permit under Chapter 62-330, F.A.C., or cause violations of state water quality standards.

17. This permit is issued based on the applicant’s submitted information that reasonably demonstrates that adverse water resource-related impacts will not be caused by the completed permit activity. If any adverse impacts result, the Agency will require the permittee to eliminate the cause, obtain any necessary permit modification, and take any necessary corrective actions to resolve the adverse impacts.

18. A Recorded Notice of Environmental Resource Permit may be recorded in the county public records in accordance with subsection 62-330.090(7), F.A.C. Such notice is not an encumbrance upon the property.

19. In addition to those general conditions in subsection (1), above, the Agency shall impose any additional project-specific special conditions necessary to assure the permitted activities will not be harmful to the water resources, as set forth in rules 62-330.301 and 62-330.302, F.A.C., Volumes I and II, as applicable, and the rules incorporated by reference in this chapter.

NOTICE OF RIGHTS

This action is final and effective on the date filed with the Clerk of the Department unless a petition for an administrative hearing is timely filed under Sections 120.569 and 120.57, F.S., before the deadline for filing a petition. On the filing of a timely and sufficient petition, this action will not be final and effective until further order of the Department. Because the administrative hearing process is designed to formulate final agency action, the hearing process may result in a modification of the agency action or even denial of the application.

Petition for Administrative Hearing A person whose substantial interests are affected by the Department’s action may petition for an administrative proceeding (hearing) under Sections 120.569 and 120.57, F.S. Pursuant to Rule 28-

106.20 and 28-106.301, F.A.C., a petition for an administrative hearing must contain the following information:

(a) The name and address of each agency affected and each agency’s file or identification number, if known;

(b) The name, address, any e-mail address, any facsimile number, and telephone number of the petitioner, if the petitioner is not represented by an attorney or a qualified representative; the name, address, and telephone number of the petitioner’s representative, if any, which shall be the address for service purposes during the course of the proceeding; and an explanation of how the petitioner’s substantial interests will be affected by the agency determination;

(c) A statement of when and how the petitioner received notice of the agency decision;

(d) A statement of all disputed issues of material fact. If there are none, the petition must so indicate;

(e) A concise statement of the ultimate facts alleged, including the specific facts that the petitioner contends warrant reversal or modification of the agency’s proposed action;

(f) A statement of the specific rules or statutes that the petitioner contends require reversal or modification of the agency’s proposed action, including an explanation of how the alleged facts relate to the specific rules or statutes; and

(g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wishes the agency to take with respect to the agency’s proposed action.

The petition must be filed (received by the Clerk) in the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, or via electronic correspondence at Agency_Clerk@dep.state.fl.us. Also, a copy of the petition shall be mailed to the applicant at the address indicated above at the time of filing.

Time Period for Filing a Petition In accordance with Rule 62-110.106(3), F.A.C., petitions for an administrative hearing by the applicant and persons entitled to written notice under Section 120.60(3), F.S., must be filed within 21 days of receipt of this written notice. Petitions filed by any persons other than the applicant, and other than those entitled to written notice under Section 120.60(3), F.S., must be filed within 21 days of publication of the notice or within 21 days of receipt of the written notice, whichever occurs first. You cannot justifiably rely on the finality of this decision unless notice of this decision and the right of substantially affected persons to challenge this decision has been duly published or otherwise provided to all persons substantially affected by the decision. While you are not required to publish notice of this action, you may elect to do so pursuant Rule 62- 110.106(10)(a).

The failure to file a petition within the appropriate time period shall constitute a waiver of that person's right to request an administrative determination (hearing) under Sections 120.569 and 120.57, F.S., or to intervene in this proceeding and participate as a party to it. Any subsequent intervention (in a proceeding initiated by another party) will be only at the discretion of the presiding officer upon the filing of a motion in compliance with Rule 28-106.205, F.A.C. If you do not publish notice of this action, this waiver will not apply to persons who have not received written notice of this action.

Extension of Time Under Rule 62-110.106(4), F.A.C., a person whose substantial interests are affected by the Department’s action may also request an extension of time to file a petition for an administrative hearing. The Department may, for good cause shown, grant the request for an extension of time. Requests for extension of time must be filed with the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, or via electronic correspondence at Agency_Clerk@dep.state.fl.us, before the deadline for filing a petition for an administrative hearing. A timely request for extension of time shall toll the running of the time period for filing a petition until the request is acted upon.

Mediation Mediation is not available in this proceeding.

FLAWAC Review The applicant, or any party within the meaning of Section 373.114(1)(a) or 373.4275, F.S., may also seek appellate review of this order before the Land and Water Adjudicatory Commission under Section 373.114(1) or 373.4275, F.S. Requests for review before the Land and Water Adjudicatory Commission must be filed with the Secretary of the Commission and served on the Department within 20 days from the date when this order is filed with the Clerk of the Department.

Judicial Review Once this decision becomes final, any party to this action has the right to seek judicial review pursuant to Section 120.68, F.S., by filing a Notice of Appeal pursuant to Florida Rules of Appellate Procedure 9.110 and 9.190 with the Clerk of the Department in the Office of General Counsel (Station #35, 3900 Commonwealth Boulevard, Tallahassee, Florida 32399-3000) and by filing a copy of the Notice of Appeal accompanied by the applicable filing fees with the appropriate district court of appeal. The notice must be filed within 30 days from the date this action is filed with the Clerk of the Department.

Executed in Hillsborough County, Florida. STATE OF FLORIDA DEPARTMENT

OF ENVIRONMENTAL PROTECTION

Shannon Herbon

Permitting Program Administrator Permitting and Waste Cleanup Programs

Attachments:

1. Project Drawings and Design Specs., 14 pages

2. Frac-Out Contingency Plan, 4 pages

3. Construction Commencement Notice/Form 62-330.350(1), 1 page

4. As-Built Certification and Request for Conversion to Operation Phase/Form 62-

330.310(1), 3 pages

5. Operation and Maintenance Inspection Certification/Form 62-330.311(1), 2 pages

6. Request for Transfer of Permit to the Perpetual Operation Entity/Form 62-330.310(2), 2 pages

7. Request to Transfer Permit/Form 62-330.340(1), 1 page

Copies furnished to:

Jessica Hamilton, Southwest District, Jessica.t.hamilton@Floridadep.gov ERP Permitting, Southwest District, sw_erp@floridadep.gov U.S. Army Corps of Engineers, tampareg@usace.army.mil Nita Sharma, Wade Trim, Nsharma@wadetrim.com

CERTIFICATE OF SERVICE

The undersigned hereby certifies that this permit, including all copies, were mailed before the close of business on December 19, 2025, to the above listed persons.

FILING AND ACKNOWLEDGMENT

FILED, on this date, under 120.52(7) of the Florida Statutes, with the designated Department Clerk, receipt of which is hereby acknowledged.

__________________________December 19, 2025 Clerk Date

TAMPA BAY WATER PROJECT No.:

DRAWING SET No.: G-1

NITA NAIK SHARMA, P.E.

LICENSE NO.

79670

NOT FOR CONSTRUCTION

PROJECT LOCATION

TAMPA BAY WATER

CROSS BAR RANCH WELLFIELD WATER TRANSMISSION MAIN

2575 Enterprise Road Clearwater, Florida 33763 Ph: 727.796.2355 www.tampabaywater.org

07153

201 North Franklin Street, Suite 1350

813.882.4373

Certificate of Authorization No.: 3952

Tampa, FL 33602 www.wadetrim.com

FINAL SUBMITTAL - SEPTEMBER 10, 2025

PROJECT NO. 07153

N.T.S.

PROJECT LOCATION:

℄ CONST. SR 52

STA. 750+20.00 =

℄ SURVEY SR 52

STA. 224+45.00

RELOCATION

EHREN

CUTOFF

STATE OF

LICENSE

P R

O

FESSIONA L ENGIN

EE

R

FLO R IDA

No. 79670

NI

TA NA IK SHA RMA

DATE: 06/12/2025

THIS ITEM HAS BEEN DIGITALLY SIGNED

AND SEALED BY NITA N. SHARMA

ON THE DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT

ARE NOT CONSIDERED SIGNED AND

SEALED AND THE SIGNATURE MUST BE

VERIFIED ON ANY ELECTRONIC COPIES.

PERMIT SET

The Individual above shall be responsible individual for following sheets included herein:

G-1, G-2, G-3, G-4 C-1, C-2, C-3, D-1, D-2, D-3, The Individual above shall be responsible individual for following sheets included herein:

CP-1, CP-2, CP-3, CP-4

http://www.tampabaywater.org

Drawn By:

Date:

Checked By:

Design By:

Date:

Date:

APPROVED BY:

2575 ENTERPRISE ROAD

CLEARWATER, FLORIDA 33763

727.796.2355

WWW.TAMPABAYWATER.ORG

DATE

Sheet No.:

TBW Project No.:

File Name:

Scale:

Sheet Designation:

OF

DESCRIPTIONREV

A

B C D E F G H

Date:

PROJECT NO. 07153

TAMPA BAY WATER

06/12/25

SEAL

201 North Franklin Street, Suite 1350

813.882.4373

Certificate of Authorization No.: 3952

Tampa, FL 33602 www.wadetrim.com

06/12/25

06/12/25

JH

JW

TYW

NITA SHARMA

HORIZ. SCALE: 1"=20'

C

P W

W

O R

K \W

A D

E -T

R

IM

JH

O R

T O

N \D

7\ G

C S-

P

LT

S- N

O T

E -S

H E

E T

.D W

G

G -2

P

LO

T

T E

D

/1 1/

1:

A

M B

Y H

O R

T O

N , J

A Y

N A

P R

O

JE

C T

M A

N A

G E

R

N

IT

A M

. N A

IK

, P

.E

BY

CROSS BAR RANCH WELLFIELD

WATER TRANSMISSION MAIN

07153

VERT. SCALE: 1"=4'

STATE OF

LICENSE

P R

O

FESSIONA L ENGIN

EE

R

FLO R IDA

No. 79670

NI

TA NA IK SHA RM

A

06/12/25

1. ALL ELEVATIONS SHOWN ON THE DRAWINGS AND IN THE SURVEY NOTES ARE REFERENCED TO

NORTH AMERICAN VERTICAL DATUM OF 1988. STATE PLANE COORDINATES ARE REFERENCED TO

NORTH AMERICAN DATUM OF 1983/90 (NAD 28/90).

2. LOCATIONS, ELEVATIONS AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES AND OTHER FEATURES ARE SHOWN ACCORDING TO THE BEST INFORMATION AVAILABLE AT THE TIME OF THE

PREPARATION OF THESE DRAWINGS, BUT DO NOT PURPORT TO BE ABSOLUTELY CORRECT. THE

CONTRACTOR SHALL OBTAIN THE LOCATIONS, ELEVATIONS AND DIMENSIONS OF ALL EXISTING

UTILITIES, STRUCTURES AND OTHER FEATURES AFFECTING HIS WORK PRIOR TO CONSTRUCTION.

3. LAND SURVEY WAS OBTAINED FROM FDOT FPID 25633415201 PLANS DATED MARCH 2021.

4. UTILITIES AND STRUCTURES THAT ARE NOT SHOWN ON THE DRAWINGS TO BE REMOVED AND

REPLACED OR RELOCATED, SHALL BE PROTECTED IN PLACE AND UTILITY SERVICE SHALL BE

MAINTAINED. WHERE TEMPORARY CONFLICTS OCCUR BETWEEN EXISTING UTILITIES AND THE NEW CONSTRUCTION, PROTECT IN PLACE OR RELOCATE THE UTILITIES AND MAINTAIN UTILITY SERVICE ALL TO THE SATISFACTION OF THE UTILITY COMPANY. UTILITIES AND STRUCTURES SHOWN ON

THE DRAWINGS TO BE REMOVED AND REPLACED OR RELOCATED, SHALL CONFORM TO THE

REQUIREMENTS OF THE APPLICABLE TECHNICAL SPECIFICATIONS.

5. PROVIDE ADEQUATE, TEMPORARY THRUST RESTRAINT AT BENDS AND TEES IN EXISTING WATER

MAINS AND OTHER PRESSURIZED CONDUITS IN PROXIMITY TO EXCAVATIONS AS REQUIRED TO

PREVENT DISLODGEMENT, SEPARATION OR LEAKAGE OF THESE FACILITIES.

6. DISCHARGE OF ANY NON-CONTAMINATED WATER FROM SOIL DEWATERING OPERATIONS TO

SURFACE WATERS, IF ANY, SHALL CONFORM TO THE FDEP GENERAL PERMIT REQUIREMENTS.

7. PROVIDE AT LEAST 48 HOURS NOTICE TO THE VARIOUS UTILITY COMPANIES IN ORDER TO PERMIT THE LOCATION OF EXISTING UNDERGROUND UTILITIES IN ADVANCE OF CONSTRUCTION. NOTIFY

THE VARIOUS UTILITY COMPANIES BY CALLING THE SUNSHINE ONE CALL CENTER

(1-800-432-4770) OR IF NECESSARY, BY CONTACTING THE UTILITY COMPANIES INDIVIDUALLY.

8. CONFIRM UTILITY TO UTILITY CLEARANCES, HORIZONTAL AND VERTICAL, AND PIPE JOINT LOCATIONS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE 62-555.314 AND 62-604.400.

9. THE HORIZONTAL ALIGNMENT OF THE REPLACEMENT WATER MAIN SHALL BE AS DIMENSIONED TO

THE SURVEY BASELINE ON THE DRAWINGS. THE CONTRACTOR SHALL OBTAIN A COPY OF THE

SURVEY AND LOCATE THE SURVEY BASELINE IN THE FIELD PRIOR TO CONSTRUCTION.

10. PIPE LAYING, LEAKAGE TESTING AND AS-BUILT DRAWINGS SHALL CONFORM TO ALL INFORMATION

INDICATED ON THE PLANS AND DETAILS OR PROJECT TECHNICAL SPECIFICATIONS.

11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL TREES WITHIN THE VICINITY OF

THE PROPOSED CONSTRUCTION IN ACCORDANCE WITH PASCO COUNTY PROTECTION

STANDARDS UNLESS OTHERWISE INDICATED FOR REMOVAL. PRUNING OF BRANCHES IS NOT

AUTHORIZED WITHOUT PRIOR APPROVAL FROM THE COUNTY, AND SHALL BE COMPLETED BY A

CERTIFIED ARBORIST.

12. CONTRACTOR TO COORDINATE WITH UTILITY POLE OWNERS TO PROVIDE SUPPORT DURING

CONSTRUCTION. UTILITY POLE OWNERS REPRESENTATIVE TO APPROVE SUPPORT METHOD PRIOR

TO BEGINNING EXCAVATION AROUND UTILITY POLES. ONCE WORK IN THE AREA HAS BEEN

COMPLETED, UTILITY REPRESENTATIVE SHALL INSPECT AND APPROVE FINAL GRADING PRIOR TO

SUPPORT BEING REMOVED.

13. REFER TO GENERAL REQUIREMENTS SECTION OF TECHNICAL SPECIFICATIONS FOR PERMIT

AGENCY COMMENTS.

14. ALL EXCAVATION AND BACKFILLING SHALL BE IN STRICT CONFORMANCE WITH TAMPA BAY WATER

AND FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS.

15. WHERE CONSTRUCTION ACTIVITIES OCCUR WITHIN THE DRIP LINES OF EXISTING TREES, TREES

ARE TO BE PROTECTED PER PASCO COUNTY NATURAL RESOURCES DIVISION REQUIREMENTS.

ANY ROOT OR CANOPY TRIMMING TO FACILITATE CONSTRUCTION OF PROPOSED FACILITIES IS

TO BE PERFORMED AT THE DIRECTION OF A CERTIFIED ARBORIST.

16. ANY AREAS DISTURBED BY CONSTRUCTION SHALL BE GRADED TO THE ORIGINAL GRADE AND

SEEDED AND MULCHED.

17. ADD TEMPORARY 1" THICK STEEL PLATES TO ACT AS SHOCK PADS OVER EXISTING 60" PIPE WITHIN

PROJECT LIMITS TO PROTECT DURING CONSTRUCTION.

18. CONTACT INFORMATION:

TAMPA BAY WATER

NAME: DANIELLE KEIRSEY, PROJECT MANAGER

PHONE: (727) 791-2377

19. TAMPA BAY WATER WILL CONTINUE TO MAINTAIN OWNERSHIP OF THE GROUTED,

OUT-OF-SERVICE 60” WATER TRANSMISSION MAIN UNTIL ROADWAY PROJECT 256334-3-52-01 IS

LET, WHERE IT WILL BE REMOVED DURING ROADWAY CONSTRUCTION, BY THE UAO.

GCS-PLTS-NOTE-SHEET.DWG G-2GENERAL NOTES AND INDEX

1. CONTACT FDOT JAMES MEYER 48 HOURS BEFORE WORKING IN FDOT R/W 352-848-2600 TO

ACTIVATE PERMIT.

2. SIDEWALKS SHOULD NOT BE CLOSED FOR MORE THAN 2 WEEKS FOR THE DURATION OF THE

PERMIT. THE CONTRACTOR WILL NEED TO PROVIDE ACCOMMODATION FOR PEDESTRIANS.

3. RESTORE FDOT R/W WITH SOD ONLY.

4. CONTACT SCOTT BROWN PASCO COUNTY FOR LOCATES OF LIGHTING FIBER AND SIGNAL

CONDUITS: PASCO COUNTY 727-849-6845

5. FOR MICROTUNNELS UNDER FDOT ROADWAYS THERE MUST BE A CONTINGENCY PLAN AND

DEWATERING PLAN. CONTINGENCY SHOULD HAVE AN EMERGENCY ON CALL MOT/TTC

CONTRACTOR AND AN EMERGENCY ASPHALT CONTRACTOR TO RESTORE THE ROADWAY IF

SOMETHING SHOULD HAPPEN TO THE MICROTUNNEL.

6. FDOT RECOMMENDS GPR BE PERFORMED ALONG PATH OF MICROTUNNEL MINIMUM OF 10' ON

EITHER SIDE OF THE CASING PIPE PRIOR TO PRE-DRILL MEETING WITH FDOT INSPECTOR WHICH IS

REQUIRED.

Checked By:

Design By:

Date:

Date:

APPROVED BY:

2575 ENTERPRISE ROAD

CLEARWATER, FLORIDA 33763

727.796.2355

WWW.TAMPABAYWATER.ORG

DATE

Sheet No.:

TBW Project No.:

File Name:

Scale:

Sheet Designation:

OF

DESCRIPTIONREV

A

B C D E F G H

Date:

PROJECT NO. 07153

TAMPA BAY WATER

06/12/25

SEAL

201 North Franklin Street, Suite 1350

813.882.4373

Certificate of Authorization No.: 3952

Tampa, FL 33602 www.wadetrim.com

06/12/25

06/12/25

JH

JW

TYW

NITA SHARMA

HORIZ. SCALE: 1"=20'

C

P W

W

O R

K \W

A D

E -T

R

IM

JH

O R

T O

N \D

7\

G C

S- P

LT

S-

LE

G

E N

D .D

W G

G

-3

P

LO

T T

E D

/1

/2

:0

P M

B Y

H O

R T

O N

, J A

Y N

A P

R O

JE

C

T M

A N

A G

E R

N

IT

A

M . N

A

IK

, P

WATER TRANSMISSION MAIN

07153

VERT. SCALE: 1"=4'

STATE OF

LICENSE

P R

O

FESSIONA L ENGIN

EE

R

FLO R IDA

No. 79670

NI

TA NA IK SHA RMA

06/12/25

°00

'00

°36

'45

90°00'00"

93°23'15"

87.30' 88.46'

229.41' 230.01' 89.11' 89.25'

10.03' 222.34' 233.30'

TAN

G

EN

T LIN

E

TA

N

G

EN

T

LI

N E

P.I. STA. 224+03.81

S.M.N.D.

& M.O.C. STA. 224+03.41

S.M.N.D.

S.

C

.I.

R

W

.P

S.

C

.I.

R

W

.P

S.

C

.I.

R

W

.P

S.

C

.I.

R

W

.P

S.

C

.I.

R

W

.P

S.

C

.I.

R

W

.P

S.

C

.I.

R

W

.P

S.

C

.I.

R

W

.P

NORTH

S.M.N.D.

S.M.N.D.

S.R . 52

SU

R

VEY LIN

E

B.O.S. = BEGINNING OF SURVEY

BWF = BARBED WIRE FENCE

E.O.S. = END OF SURVEY

EXIST. = EXISTING

F.C.I.R. = FOUND CAPPED IRON ROD

FDOT = FLORIDA DEPARTMENT OF TRANSPORTATION

F.I.P. = FOUND IRON PIPE

F.I.R. = FOUND IRON ROD

FND. N&D = FOUND NAIL AND DISK

F.M.N.D. = FOUND MAG NAIL & DISK

F.P.K.N.D. = FOUND PARKER-KALON NAIL & DISK

F.R.R.S. = FOUND RAIL ROAD SPIKE

ID. = IDENTIFICATION

LB = LICENSED BUSINESS

LF = LINEAR FOOT (FEET)

MES = MITERED END SECTION

M.O.C. = MIDDLE OF CURVE

PAVT. = PAVEMENT

P.C. = POINT OF CURVATURE

P.I. = POINT OF INTERSECTION

P.O.T. = POINT ON TANGENT

PT. = POINT

P.T. = POINT OF TANGENCY

RCP = REINFORCED CONCRETE PIPE

REF. = REFERENCE

RPS = REVOLUTION PROFESSIONAL SERVICES

S.C.I.R. = SET CAPPED IRON ROD 1/2" (RPS LB 7889)

S.C.I.R. W.P. = SET CAPPED IRON ROD 1/2" (RPSWITNES LB 7889)

SHLDR = SHOULDER

SMF = STORMATER MANAGEMENT FACILITY

S.M.N.D. = SET MAG NAIL & DISK (RPS LB 7889)

S.R. = STATE ROAD

STA. = STATION

TH = TEST HOLE

NTS = NOT TO SCALE

WATER MAIN

WATER MAIN & CASING PIPE

RECLAIMED WATER MAIN

OVERHEAD ELECTRIC

UNDERGROUND ELECTRIC

BURIED TELEPHONE

BURIED FIBER OPTIC

STORM MAIN

FENCE

FDOT RIGHT OF WAY

PIPE/FENCE TO BE REMOVED

LIMITS OF DISTURBANCE

R/W

TEST HOLE

WATER CONTROL VALVE

UTILITY POLE

STORM MANHOLE

STORM STRUCTURE AND MES

CONCRETE SLAB AND POST

SOIL BORING

BUTTERFLY VALVE

CAP

TREE

TREE REMOVAL

SD

WATER

LEGEND ABBREVIATIONS SURVEY CONTROL

GCS-PLTS-LEGEND.DWG

G-3LEGEND, ABBREVIATIONS AND SURVEY CONTROL

TBM 80003

EL.=78.30'

N=1449912.20 E=513220.22 X 660

4'

SW

F W

1) B

W

R/ W

P

OST

GA

TE CA

TT

LE

GA

P

GA

TE

GATE

SH

EL

L

AS

PH

AL

T GATE

WOOD

SIGN DUMPSTER W/

6' WOOD FENCE

4' BWF

SD

PREVIOUS

FDOT R/W

W

AT

ER

W

AT

ERVCW

VCW

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

R/

WEXIST. FDOT R/W

EXIST. FDOT R/W

PROP. FDOT R/W

TAMPA BAY WATER

50' PERMANENT

EASEMENT

O.R. 1497, PG. 751

(POSITION BASED ON

COORDINATE DATA FROM

SKETCH PREPARED

BY TAMPA BAY WATER)

TAMPA BAY WATER

50' PERMANENT EASEMENT

O.R. 1497, PG. 751

(POSITION BASED ON

COORDINATE DATA FROM

SKETCH PREPARED

BY TAMPA BAY WATER)

Drawn By:

Date:

Checked By:

Design By:

Date:

Date:

APPROVED BY:

2575 ENTERPRISE ROAD

CLEARWATER, FLORIDA 33763

727.796.2355

WWW.TAMPABAYWATER.ORG

DATE

Sheet No.:

TBW Project No.:

File Name:

Scale:

Sheet Designation:

OF

DESCRIPTIONREV

A

B C D E F G H

Date:

PROJECT NO. 07153

TAMPA BAY WATER

06/12/25

SEAL

201 North Franklin Street, Suite 1350

813.882.4373

Certificate of Authorization No.: 3952

Tampa, FL 33602 www.wadetrim.com

06/12/25

06/12/25

JH

JW

TYW

NITA SHARMA

HORIZ. SCALE: 1"=20'

C

P W

W

O R

K \W

A D

E -T

R

IM

JH

O R

T O

N \D

7\

C U

P -P

LT

S-

E X

IS

T

-S U

R V

E Y

.D W

G

G -4

P

LO

T

T E

D

/1

/2

:0

P

M B

Y H

O R

T O

N , J

A Y

N A

P R

O

JE

C T

M A

N A

G E

R

N

IT

A M

. N A

IK

, P

WATER TRANSMISSION MAIN

07153

VERT. SCALE: 1"=4'

STATE OF

LICENSE

P R

O

FESSIONA L ENGIN

EE

R

FLO R IDA

No. 79670

NI

TA NA IK SHA RMA

06/12/25

G-4STATE ROAD 52

STA 10+00 TO STA 15+50

EXISTING CONDITIONS

CUP-PLTS-Exist-Survey.DWG

N=1449912.20 E=513220.22 X 660

℄ DRIVEWAY

751+05.21, 67.00' RT.

4'

SW

F W

1)

BW

R/ W

P

OST

GA

TE CA

TT

LE

GA

P

GA

TE

GATE

SH

EL

L

AS

PH

AL

T GATE

WOOD

SIGN DUMPSTER W/

6' WOOD FENCE

4' BWF

SD

EB

SR

(S

CH

RAD

ER

H

WY.)

WB

SR

(S

CH

RA

DER

H

WY.)

PREVIOUS

FDOT R/W

10' SHLDR.

8' SHLDR. PAVT.

PRIVATE

DRIVE

749+83.11, 132.00' LT.

MATCH EXIST.

751+67.43, 128.00' RT.

MATCH EXIST.

6" CONC. DRWY.

PER FDOT INDEX 330-001

W

AT

ER

W

AT

ERVCW

VCW

S-2035AA

.7077

.20

SM

F-

3-

4B

.10

.80

.10

SM

F-

3-

5A

.00

.907

9.4

S-267

S-265

S-268

S-270

S-269

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

50' TAMPA BAY

WATER EASEMENT

50' TAMPA BAY

WATER EASEMENT

42" PIPE

(BY FDOT

CONTRACTOR)

EXIST. FDOT R/W

EXIST. FDOT R/W

℄ MEDIAN OPENING

STA.751+34.89

5 LF OF 24" PIPE

(BY FDOT CONTRACTOR)

370 LF OF 42" PIPE

(BY FDOT CONTRACTOR)

305 LF OF 19" X 30" PIPE

(BY FDOT CONTRACTOR)

10' SHLDR.

8' SHLDR. PAVT.

8' SHLDR.

8' SHLDR.

4' SHLDR. PAVT.

177 LF OF 14" X 23" PIPE

(BY FDOT CONTRACTOR)

10' SHLDR.

8' SHLDR. PAVT.

10' SHLDR.

5' SHLDR. PAVT.

12' SHARED

USE PATH

SUMP

12' SHARED

USE PATH

TYPE E

C & G

VAR. WIDTH

CONC. TRAF. SEP.

(TYPE I, OPTION II)

751+46.07, 128.00' RT.

MATCH EXIST.

749+95.67, 132.00' LT.

MATCH EXIST.

GRADED DRWY. PER

FDOT INDEX

330-001

TYPE E

C & G

℄ DRIVEWAY

750+14.06, 67.00' LT.

CONCRETE SLAB W/

POST AND WIRES

METAL POST

63 LF OF 18" PIPE

(BY FDOT CONTRACTOR)

EXISTING 60" TAMPA

BAY WATER PIPELINE

PROP. FDOT R/W

EX. 36" OUTLET

TAMPA BAY WATER

50' PERMANENT

EASEMENT

O.R. 1497, PG. 751

(POSITION BASED ON

COORDINATE DATA FROM

SKETCH PREPARED

BY TAMPA BAY WATER)

TAMPA BAY WATER

50' PERMANENT EASEMENT

O.R. 1497, PG. 751

(POSITION BASED ON

COORDINATE DATA FROM

SKETCH PREPARED

BY TAMPA BAY WATER)

Drawn By:

Date:

Checked By:

Design By:

Date:

Date:

APPROVED BY:

2575 ENTERPRISE ROAD

CLEARWATER, FLORIDA 33763

727.796.2355

WWW.TAMPABAYWATER.ORG

DATE

Sheet No.:

TBW Project No.:

File Name:

Scale:

Sheet Designation:

OF

DESCRIPTIONREV

A

B C D E F G H

Date:

PROJECT NO. 07153

TAMPA BAY WATER

06/12/25

SEAL

201 North Franklin Street, Suite 1350

813.882.4373

Certificate of Authorization No.: 3952

Tampa, FL 33602 www.wadetrim.com

06/12/25

06/12/25

JH

JW

TYW

NITA SHARMA

HORIZ. SCALE: 1"=20'

C

P W

W

O R

K \W

A D

E -T

R

IM

JH

O R

T O

N \D

7\ C

U P

-P

LT

S-

LO

D .D

W G

C

-1 L

IM

IT

S

P

LO

T T

E D

/1

/2

:4

P M

B Y

H O

R T

O N

, J A

Y N

A P

R O

JE

C

T M

A N

A G

E R

N

IT

A

M . N

A

IK

, P

WATER TRANSMISSION MAIN

07153

VERT. SCALE: 1"=4'

STATE OF

LICENSE

P R

O

FESSIONA L ENGIN

EE

R

FLO R IDA

No. 79670

NI

TA NA IK SHA RM

A

06/12/25

C-1STATE ROAD 52

STA 10+00 TO STA 15+50

TREE REMOVAL AND LIMITS OF DISTURBANCE

CUP-PLTS-LOD.DWG

N=1449912.20 E=513220.22 X 660

℄ DRIVEWAY

751+05.21, 67.00' RT.

4'

SW

F W

1)

BW

R/ W

P

OST

GA

TE CA

TT

LE

GA

P

GA

TE

GATE

SH

EL

L

AS

PH

AL

T GATE

WOOD

SIGN DUMPSTER W/

6' WOOD FENCE

4' BWF

SD

EB

SR

(S

CH

RAD

ER

H

WY.)

WB

SR

(S

CH

RA

DER

H

WY.)

PREVIOUS

FDOT R/W

10' SHLDR.

8' SHLDR. PAVT.

PRIVATE

DRIVE

749+83.11, 132.00' LT.

MATCH EXIST.

751+67.43, 128.00' RT.

MATCH EXIST.

6" CONC. DRWY.

PER FDOT INDEX 330-001

W

AT

ER

W

AT

ERVCW

VCW

S-2035AA

.7077

.20

SM

F-

3-

4B

.10

.80

.10

SM

F-

3-

5A

.00

.907

9.4

S-267

S-265

S-268

S-270

S-269

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

R/ W

50' TAMPA BAY

WATER EASEMENT

50' TAMPA BAY

WATER EASEMENT

42" PIPE

(BY FDOT

CONTRACTOR)

EXIST. FDOT R/W

EXIST. FDOT R/W

℄ MEDIAN OPENING

STA.751+34.89

5 LF OF 24" PIPE

(BY FDOT CONTRACTOR)

370 LF OF 42" PIPE

(BY FDOT CONTRACTOR)

305 LF OF 19" X 30" PIPE

(BY FDOT CONTRACTOR)

10' SHLDR.

8' SHLDR. PAVT.

8' SHLDR.

8' SHLDR.

4' SHLDR. PAVT.

177 LF OF 14" X 23" PIPE

(BY FDOT CONTRACTOR)

10' SHLDR.

8' SHLDR. PAVT.

10' SHLDR.

5' SHLDR. PAVT.

12' SHARED

USE PATH

SUMP

12' SHARED

USE PATH

TYPE E

C & G

VAR. WIDTH

CONC. TRAF. SEP.

(TYPE I, OPTION II)

751+46.07, 128.00' RT.

MATCH EXIST.

749+95.67, 132.00' LT.

MATCH EXIST.

GRADED DRWY. PER

FDOT INDEX

330-001

TYPE E

C & G

℄ DRIVEWAY

750+14.06, 67.00' LT.

CONCRETE SLAB W/

POST AND WIRES

METAL POST

63 LF OF 18" PIPE

(BY FDOT CONTRACTOR)

EXISTING 60" TAMPA

BAY WATER PIPELINE

PROP. FDOT R/W

EX. 36" OUTLET

TAMPA BAY WATER

50' PERMANENT

EASEMENT

O.R. 1497, PG. 751

(POSITION BASED ON

COORDINATE DATA FROM

SKETCH PREPARED

BY TAMPA BAY WATER)

TAMPA BAY WATER

50' PERMANENT EASEMENT

O.R. 1497, PG. 751

(POSITION BASED ON

COORDINATE DATA FROM

SKETCH PREPARED

BY TAMPA BAY WATER)

C-2STATE ROAD 52

PLAN

STA 10+00 TO STA 15+50

Drawn By:

Date:

Checked By:

Design By:

Date:

Date:

APPROVED BY:

2575 ENTERPRISE ROAD

CLEARWATER, FLORIDA 33763

727.796.2355

WWW.TAMPABAYWATER.ORG

DATE

Sheet No.:

TBW Project No.:

File Name:

Scale:

Sheet Designation:

OF

DESCRIPTIONREV

A

B C D E F G H

Date:

PROJECT NO. 07153

TAMPA BAY WATER

06/12/25

SEAL

201 North Franklin Street, Suite 1350

813.882.4373

Certificate of Authorization No.: 3952

Tampa, FL 33602 www.wadetrim.com

06/12/25

06/12/25

JH

JW

TYW

NITA SHARMA

HORIZ. SCALE: 1"=20'

C

P W

W

O R

K \W

A D

E -T

R

IM

JH

O R

T O

N \D

7\ C

U P

-P

LT

S- P

LA

N

.D W

G

C -2

P

LA

N

P

LO

T T

E D

/1

/2

:4

P M

B Y

H O

R T

O N

, J A

Y N

A P

R O

JE

C

T M

A N

A G

E R

N

IT

A

M . N

A

IK

, P

WATER TRANSMISSION MAIN

07153

VERT. SCALE: 1"=4'

STATE OF

LICENSE

P R

O

FESSIONA L ENGIN

EE

R

FLO R IDA

No. 79670

NI

TA NA IK SHA RM

A

06/12/25

CUP-PLTS-PLAN.DWG

STATE ROAD 52

PROFILE

STA 10+00 TO STA 15+50

C-3

HORIZ. SCALE: 1"=20'

VERT. SCALE: 1"=4'

Drawn By:

Date:

Checked By:

Design By:

Date:

Date:

APPROVED BY:

2575 ENTERPRISE ROAD

CLEARWATER, FLORIDA 33763

727.796.2355

WWW.TAMPABAYWATER.ORG

DATE

Sheet No.:

TBW Project No.:

File Name:

Scale:

Sheet Designation:

OF

DESCRIPTIONREV

A

B C D E F G H

Date:

PROJECT NO. 07153

TAMPA BAY WATER

06/12/25

SEAL

201 North Franklin Street, Suite 1350

813.882.4373

Certificate of Authorization No.: 3952

Tampa, FL 33602 www.wadetrim.com

06/12/25

06/12/25

JH

JW

TYW

NITA SHARMA

HORIZ. SCALE: 1"=20'

C

P W

W

O R

K \W

A D

E -T

R

IM

JH

O R

T O

N \D

7\ C

U P

-P

LT

S- P

LA

N

.D W

G

C -3

P R

O

FI

LE

P

LO

T T

E D

/1

/2

1:

A

M B

Y H

O R

T O

N , J

A Y

N A

P R

O

JE

C T

M A

N A

G E

R

N

IT

A M

. N A

IK

, P

WATER TRANSMISSION MAIN

07153

VERT. SCALE: 1"=4'

STATE OF

LICENSE

P R

O

FESSIONA L ENGIN

EE

R

FLO R IDA

No. 79670

NI

TA NA IK…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .