This is an electrical drawings document prepared for the Jordan School District detailing emergency power installations to IT closets across ten facilities in Utah as part of Bid Package #2. The project encompasses emergency power circuits for IT infrastructure at Jordan Hills Elementary, Riverside Elementary, Terra Linda Elementary, Westvale Elementary, Welby Elementary, Elk Ridge Middle School, Joel P Jensen Middle School, South Valley School, Auxiliary Services Building, and JATC North Campus. The scope of work includes providing emergency power receptacles (primarily 4-plex red receptacles), installing new circuit breakers in existing panels, running conduit and wiring connections, and in some cases providing new load centers or panels. The drawings specify detailed electrical layouts for each facility, including symbol schedules, mounting heights, conductor sizing requirements, voltage drop calculations, and standard installation notes. Specific work instructions for each site detail modifications to existing electrical systems, such as converting duplex receptacles to emergency red receptacles, adding new 20-ampere single-pole circuit breakers, and establishing new transformer installations where required.

The drawings establish technical specifications for all electrical work, including requirements to verify existing circuit compatibility, coordinate with mechanical contractors, maintain fire-rated penetrations, and comply with the National Electrical Code. Contractors are required to verify all electrical loads, equipment dimensions, and locations before beginning work, and ensure branch circuit voltage drop remains below three percent for 15-ampere loads. The document includes comprehensive abbreviations, typical raceway support methods, transformer wall mounting details, and general demolition notes addressing coordination, safety, and existing equipment restoration. All emergency power receptacles are to be marked with red coloring to distinguish them from standard receptacles, and contractors must relocate or rewire any existing devices that obstruct construction while maintaining all other building systems in working condition.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EMERGENCY POWER TO IT CLOSETS

FOR THE

JORDAN HILLS ES - 8892 S 4800 W, WEST JORDAN

RIVERSIDE ES - 8737 S 122O W, WEST JORDAN

TERRA LINDA ES - 8400 W OLD BINGHAM HWY, WEST JORDAN

WESTVALE ES - 2300 W GARDNER LN, WEST JORDAN

WELBY ES - 4130 W 9580 S, SOUTH JORDAN

ELK RIDGE MS - 2636 W 9800 S, SOUTH JORDAN

JOEL P JENSEN MS - 8105 S 3200 W, WEST JORDAN

SOUTH VALLEY SCHOOL - 8400 S REDWOOD RD., WEST JORDAN

AUXILIARY SERVICES BUILDING - 7959 S REDWOOD RD., WEST JORDAN

JATC NORTH - 9301 S WIGHT FORT RD., WEST JORDAN

JORDAN SCHOOL DISTRICT

BID No. 26KP18

APRIL 2026

NUMBER TWO

BID PACKAGE

SYMBOL DESCRIPTION

MOUNTING

HEIGHT NOTES SYMBOL DESCRIPTION

MOUNTING

HEIGHT NOTES

ONE CIRCUIT, HOME RUN TO PANEL

TWO CIRCUIT, HOME RUN TO PANEL

THREE CIRCUIT, HOME RUN TO PANEL

CONDUIT RUN CONCEALED IN WALL OR CEILING

CONDUIT RUN CONCEALED IN FLOOR OR GROUND

CONDUIT UP

CONDUIT DOWN

GENERAL

CONDUIT STUB LOCATION CONDUIT

CAP

CONDUIT/CIRCUIT CONTINUATION

JUNCTION BOX ('F' IN FLOOR) AS NOTED

LIGHT FIXTURE (LETTER DESIGNATES TYPE)X

X X

EQUIPMENT NUMBER

842 ARCHITECTURAL ROOM NUMBER

DEVICE/EQUIPMENT (TEXT DESIGNATES TYPE) SEE SCHEDULEX

DEVICE/EQUIPMENT (TEXT DESIGNATES TYPE) SEE SCHEDULE/LEGENDX

EQUIPMENT PANEL SEE DRAWINGS +72" 6.

CABLE TRAY (BASKET/LADDER) AS NOTED

GROUND BUS BAR +18" 6.

DUPLEX RECEPTACLE 9.

5mA GFCI CIRCUIT BREAKER PROTECTED RECEPTACLE 13.5mA GFCI CIRCUIT BREAKER PROTECTED RECEPTACLE 13.

TOMBSTONE RECEPTACLE

POWER POLE

POWER

UPPER OUTLET

SWITCH CONTROLLEDDUPLEX RECEPTACLE 2. 9.

+18" OR

AS NOTED

SIMPLEX RECEPTACLE 2. 9.

+18" OR

AS NOTED

TAMPER-PROOF RECEPTACLE 2. 9.

+18" OR

AS NOTED

DUPLEX RECEPTACLE WITH USB OUTLET 2. 9.

+18" OR

AS NOTED

WEATHERPROOF RECEPTACLE 2. 9.AS NOTED

+24" OR

ISOLATED GROUND RECEPTACLE 2. 9.

+18" OR

AS NOTED

GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE 2. 9.

+18" OR

AS NOTED

GROUND FAULT INTERRUPTER FOURPLEX RECEPTACLE 2. 9.

+18" OR

AS NOTED

TVSS PROTECTED RECEPTACLE 2. 9.

+18" OR

AS NOTED

RECEPTACLE SWITCH PACK

ABOVE

CEILING

FLAT PANEL DISPLAY WALL BOX, TVSS RECEPT.,

SPEC. 26 2726

SEE DIAGRAM &

DATA AND OTHER DEVICES, REFER TO DIAGRAMS AS NOTED

CEILING PROJECTION SYSTEM CEILING BOX AND SPEC.

SEE DIAGRAMABOVE

CEILING

CLOCK OUTLET 2.+90"

PLUGMOLD/SURFACE RACEWAY 2. SEE SPEC.

+46" OR

AS NOTED

DUPLEX RECEPTACLE 2. 9. 11.

+18" OR

AS NOTED

DUPLEX RECEPTACLE EMERGENCY POWER (RED) 2. 9. 11.

+18" OR

AS NOTED

FOURPLEX RECEPTACLE 2. 9. 11.

+18" OR

AS NOTED

FOURPLEX RECEPTACLE EMERGENCY POWER (RED) 2. 9. 11.

+18" OR

AS NOTED

CORD DROP SEE DIAGRAM

DOOR BELL CHIME +90" 2.

FLOOR BOX - SEE SCHEDULE SEE DIAGRAM, SPEC. FLOOR

POKE THRU - SEE SCHEDULE SEE DIAGRAM, SPEC. FLOOR

MOTOR OUTLET

TO SUIT

EQUIP.

PUSHBUTTON 2.+46"

NON-FUSED DISCONNECT SWITCH 5. 6.+60"

FUSED DISCONNECT SWITCH 5. 6.+60"

BREAKER DISCONNECT SWITCH 5. 6.+60"

MANUAL STARTER THERMAL OVERLOAD SWITCH WITH PILOT LIGHT 2.+46"

MAGNETIC STARTER 6. 7.+60"

MAGNETIC STARTER / DISCONNECT COMBINATION +60" 6. 7.

VARIABLE FREQUENCY DRIVE +66" 6.

PANEL BOARD +72" 6.

MAIN DISTRIBUTION PANEL

UTILITY METER +72" 6.

CORD REEL SEE DIAGRAM

CONTROLLED DUPLEX RECEPTACLE 2. 9.

+18" OR

AS NOTED

CONTROLLED FOURPLEX RECEPTACLE 2. 9.

+18" OR

AS NOTED

SPECIAL PURPOSE OUTLET 2. 10. W/CAP.+18" OR

AS NOTED

TELECOMMUNICATIONS

WALL PHONE 2.W

+60" OR

AS NOTED

DATA OUTLET , ONE CABLE 2. 9. 11.+18" OR

AS NOTED

DATA OUTLET, TWO CABLES 2. 9. 11.+18" OR

AS NOTED

DATA OUTLET, THREE CABLES 2. 9. 11.+18" OR

AS NOTED

DATA OUTLET , "X" INDICATES QUANTITYX 2. 9. 11.+18" OR

AS NOTED

DATA OUTLET , CEILING AS NOTED

TELEVISION OUTLET

+18" OR

AS NOTED

2. 9. 11.

TELEPHONE TERMINAL BOARD

EQUIPMENT CEILING RACK CEILING

EQUIPMENT 4-POST RACK/CABINET 18. SEE SPEC.AS NOTED

EQUIPMENT 2-POST 18. SEE SPEC.AS NOTED

SPLITTER

ABOVE

CEILING

VIA

ABOVE

CEILING

FIBER BDA

ABOVE

CEILING

ANTENNAXX CEILINGPS = PUBLIC SERVICE

COM = CELLULAR/COMMERCIAL

WIRELESS ACCESS POINT, TWO CABLES 11.

SOLID = WALL, DASHED = CEILING

SYMBOL SCHEDULE

1. SEE FIXTURE SCHEDULE FOR TYPE, MOUNTING AND WATTAGE.

4. SUBSCRIPT INDICATES FIXTURES TO BE CONTROLLED.

8. DOUBLE ARROWS INDICATE A DOUBLE FACE UNIT.

3. REFER TO DRAWINGS FOR DIRECTIONAL ARROWS.

STANDARD MOUNTING HEIGHT UNLESS OTHERWISE NOTED ON PLANS

11. SOLID BOX AROUND DEVICE INDICATES INSTALLED IN FLOOR,

6. HEIGHT MEASURED TO TOP OF THE BOX FROM FINISHED FLOOR.

5. NEMA TYPE 'ND' NON-FUSED UNLESS NOTED 'F' (FUSED). USE 'HD' 480V.

2. HEIGHT MEASURED TO CENTER LINE OF THE BOX FROM THE FINISHED FLOOR.

10. SUBSCRIPT INDICATES NEMA CONFIGURATION.

* TYPICAL SYMBOL SCHEDULE. SOME SYMBOLS MAY NOT BE USED IN THIS SET OF DRAWINGS.

12. COORDINATE WITH DOOR HARDWARE SUPPLIER.

7. PROVIDE H.O.A. AND S.S. PUSHBUTTONS AS REQUIRED.

13. FOR WATER COOLER LOCATION, SEE DIAGRAM R002. FOR ALL OTHER LOCATIONS

MOUNT AT +16" TO BOTTOM OF THE BOX FROM FINISHED FLOOR, OR AS NOTED.

9. DEVICES NOTED WITH AN "A" ADJACENT TO IT INDICATES TO COORDINATE

14. ARROWS SHOWN ON DEVICE INDICATE THE SENSOR AIMING LOCATION.

15. CAMERA NUMBERS ARE SHOWN INSIDE THE CAMERA SYMBOL. CAMERA TYPES ARE

16. MOUNT ON TRACK OF OVERHEAD DOOR 6" FROM TOP OF DOOR UNLESS OVERHEAD

17. INSTALL DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.

SHOWN IN CAMERA TAGS.

DOOR IS ROLL UP DOOR, THEN MOUNT PER MANUFACTURER'S INSTRUCTIONS.

DASHED BOX AROUND DEVICE INDICATES INSTALLED IN CEILING.

NOTES:

18. DASHED LINE INDICATES EQUIPMENT CLEARANCES. ARROW DENOTES FRONT OF RANK.

19. SPEAKER TO BE MOUNTED IN HORIZONTAL POSITION.

20. MOUNTING HEIGHTS IS TO BOTTOM OF DISPLAY.

WITH MILLWORK SHOP DRAWINGS AND ELEVATIONS FOR HEIGHT.

GENERAL NOTES

1. CONSULT ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL LIGHTING

FIXTURES.

2. VERIFY ALL EQUIPMENT DIMENSIONS AND LOCATIONS BEFORE BEGINNING ROUGH IN. CONSULT ALL

APPLICABLE CONTRACT DRAWINGS AND SHOP DRAWINGS TO INSURE NEC CODE CLEARANCES

REQUIRED AROUND ALL ELECTRICAL EQUIPMENT.

3. CONTRACTOR SHALL VERIFY ALL ELECTRICAL LOADS (VOLTAGE, PHASE, CONNECTION

REQUIREMENTS, ETC.) OF ALL EQUIPMENT FURNISHED UNDER ALL DIVISIONS, INCLUDING ALL EXISTING

EQUIPMENT TO BE RE-USED. REVIEW ALL SHOP DRAWINGS AND EXISTING EQUIPMENT BEFORE

BEGINNING ROUGH IN.

4. SEE SECTION 265100 (16510) OF THE SPECIFICATION REQUIRED COORDINATION MEETINGS WITH

MECHANICAL AND CEILING CONTRACTORS.

5. SEE APPLICABLE SHOP DRAWINGS FOR ROUGH IN LOCATION OF ALL EQUIPMENT, WIRING DEVICES, ETC. WHERE APPLICABLE MOUNT ALL WIRING DEVICES ABOVE BACK SPLASH EXCEPT THOSE SERVING

UNDER COUNTER EQUIPMENT.

6. SEE SPECIFICATION FOR ENERGY SAVING LAMP AND BALLAST REQUIREMENTS.

7. FINISHES OF ALL LIGHT FIXTURES SHALL BE AS SELECTED BY ARCHITECT.

8. THE ELECTRICAL CONTRACTOR SHALL NOTIFY AND COOPERATE WITH THE MECHANICAL CONTRACTOR SUCH THAT NO PIPING, DUCTS, OR EQUIPMENT FOREIGN TO THE OPERATION OF THE ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE INSTALLED IN, ENTER OR PASS THRU ELECTRICAL ROOMS OR

SPACES, OR ABOVE OR BELOW ELECTRICAL EQUIPMENT IN OTHER AREAS.

9. ELECTRICAL BOXES SHALL NOT BE LOCATED IN MASONRY COLUMNS IN BRICK WALLS OR IN GROUTED CELLS ADJACENT TO OPENINGS. COORDINATE LOCATION OF BOXES WITH MASONRY CONTRACTOR.

10. ALL PENETRATIONS OF FIRE RATED FLOORS, WALLS, AND CEILINGS SHALL BE SEALED WITH

APPROVED MATERIAL TO MAINTAIN FIRE RATING OF SURFACE PENETRATED.

11. CONTRACTOR SHALL VERIFY FURNITURE LAYOUT PRIOR TO ANY FLOORBOX OR POKE-THRU

INSTALLATION. COORDINATE EXACT LOCATION OF FLOOR BOX OR POKE-THRU WITH OWNER AND

FURNITURE PROVIDER PRIOR TO ROUGH-IN.

12. PROVIDE ALL EMERGENCY PANELS REFERENCED IN THIS BID SET, EXISTING OR NEW, WITH A RED LABEL WITH THE PANEL NAME. IF AN EXISTING PANEL HAS A LABEL OF ANOTHER COLOR REMOVE THAT

LABEL AND PROVIDE THE NEW.

13. SINCE THE DRAWINGS ARE A SMALL SCALE IT IS IMPOSSIBLE TO LOCATE DEVICES EXACTLY WHERE

THEY ARE DESIRED. VERIFY THE ACTUAL LOCATION OF ALL DEVICES WITH THE OWNERS

REPRESENTATIVE.

14. CIRCUITS EXTENDING OVER 70' FOR 120 VOLT AND 115' FOR 277 VOLT 20 AMP CIRCUITS SHALL BE RUN

WITH CONDUCTORS PER TABLE BELOW.

A. THESE ARE BASED ON MAXIMUM LENGTH OF CIRCUIT.

B. PERFORM VOLTAGE DROP CALCULATIONS AND PROVIDE CONDUCTOR SIZE TO KEEP BRANCH CIRCUIT

VOLTAGE DROP LESS THAN 3% WITH A 15 AMP LOAD.

C. CONTRACTOR SHALL ENSURE THAT THE INSTALLATION OF EACH BRANCH CIRCUIT STAYS WITHIN 3%

VOLTAGE DROP FOR A 15 AMP LOAD. IF NECESSARY, CONTRACTOR SHALL INCREASE WIRE AND

CONDUIT SIZE TO MEET THE STANDARD AT NO ADDITIONAL COST TO OWNER.

MAXIMUM LENGTH

<70 MIN. #12 AWG

70 - 115

115 - 170

170 - 270

20 AMP MINIMUM BRANCH CIRCUIT CONDUCTOR SIZING

BRANCH CIRCUIT VOLTAGE

CONDUCTOR LENGTH (FT) 120 VOLT 277 VOLT

271 - 380

>380

MIN. #12 AWG

MIN. #10 AWG MIN. #12 AWG

MIN. #8 AWG MIN. #10 AWG

MIN. #6 AWG MIN. #8 AWG

NOTE B MIN. #8 AWG

NOTE B NOTE B

1. COORDINATE ALL NEW ELECTRICAL EQUIPMENT REQUIREMENTS AND MAKE CONNECTION TO EXISTING SYSTEMS. THIS INCLUDES LIGHTING, POWER, SIGNAL, RACEWAY AND OTHER SYSTEMS INCLUDED UNDER DIVISION 26 (16).

2. RELOCATE, REWIRE AND/OR RECONNECT EXISTING ELECTRICAL DEVICES AND/OR EQUIPMENT THAT FOR ANY REASON

OBSTRUCTS CONSTRUCTION.

3. CONCEAL ALL RACEWAY AND WIRING IN EXISTING WALLS, CEILINGS, FLOORS, ETC. EXCEPT WHERE THE USE OF SURFACE

METAL RACEWAYS (E.G. WIRE MOLD) IS INDICATED ON DRAWINGS OR IN SPEC.

4. LEAVE ALL EXISTING EQUIPMENT, IN PORTIONS OF THE BUILDING NOT BEING REMODELED, IN WORKING CONDITION. RESTORE

ALL INTERRUPTED BRANCH CIRCUITS, FEEDERS, ETC. TO WORKING CONDITION.

5. EXISTING RACEWAYS MAY BE REUSED (IN PLACE) WHERE POSSIBLE, AND WHERE IN COMPLIANCE WITH THE SPECIFICATIONS AND THE INTENT OF THE CONTRACT DOCUMENTS. INSURE INTEGRITY OF EXISTING RACEWAY BEFORE REUSE.

6. REMOVE ALL RACEWAYS, CONDUCTORS, BOXES, DEVICES, EQUIPMENT, ETC. THAT ARE NOT TO BE REUSED.

7. REMOVE EXISTING LIGHT FIXTURES WHICH ARE NOT TO BE REUSED, PLACE IN CARTON, LABEL APPROPRIATELY, AND RETURN

TO OWNER, OR PROPERLY DISPOSE OF FIXTURES THAT THE OWNER CHOOSES NOT TO KEEP.

8. DO NOT PENETRATE STRUCTURAL ELEMENTS OF FLOORS, WALLS, CEILINGS, ROOFS, ETC.

9. DISCONNECT AND RECONNECT ANY/ALL FIXTURES, DEVICES, EQUIPMENT, ETC. REQUIRED FOR PROPER COMPLETION OF THE

WORK.

DEMOLITION NOTES

ABBREV.

# NUMBER

AC ALTERNATING CURRENT

A.F.F. ABOVE FINISH FLOOR

AIC AMPS INTERRUPTING CAPACITY

AM AMPS METER

AMP AMPERE

ANN ANNUNCIATOR

ATS AUTOMATIC TRANSFER SWITCH

AUX AUXILIARY

AWG AMERICAN WIRE GAUGE

BC BARE COPPER

BFG BELOW FINISH GRADE

C CONDUIT

CAB CABINET

CATB COMMUNITY ANTENNA TELEVISION

CATV CABLE TELEVISION

CKT CIRCUIT

CLG CEILING

CNTR CONTRACTOR

C.O. CONDUIT ONLY

CRT COMPUTER TERMINAL

CT CURRENT TRANSFORMER

CU COPPER

C/W COMPLETE WITH

DB DECIBEL

DC DIRECT CURRENT

DWG DRAWING

(E) EXISTING

EC EMPTY CONDUIT

EG EMERGENCY GENERATOR

EMT ELECTRICAL METALLIC TUBING

EX EXPLOSION PROOF

FACP FIRE ALARM CONTROL PANEL

FC FOOT CANDLE

FT FOOT

GFI GROUND FAULT INTERRUPTER

GND GROUND

GRC GALVANIZED RIGID CONDUIT

HP HORSE POWER

HZ HERTZ

IG ISOLATED GROUND

IMC INTERMEDIATE METALLIC CONDUIT

IN INCH

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT AMPERES

KVAR KILOVARS

KW KILOWATT

LRA LOCKED ROTOR AMPS

LTG LIGHTING

MNF MANUFACTURER

MAX MAXIMUM

MB MAIN BUS

MCC MOTOR CONTROL CENTER

MCM 1000 CIRCULAR MILLS

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MTG MOUNTING

MTR MOTOR

N/A NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECT. MANUFAC. ASSOC.

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION ASSOC.

N.I.C. NOT IN CONTRACT

NO NORMALLY OPENED

NTS NOT TO SCALE

OS & Y OUTSIDE SCREW & YOKE

PB PUSHBUTTON

PF POWER FACTOR

PFR PHASE FAILURE RELAY

PNL PANEL

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE CONDUIT

(R) RELOCATE

RECEP RECEPTACLE

REQ REQUIREMENT

RLA RATED LOAD AMPS

RMS ROOT MEAN SQUARE

SE SERVICE ENTRANCE

SPEC SPECIFICATIONS

SPKR SPEAKER

SS SELECTOR SWITCH

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

TTB TELEPHONE TERMINAL BOARD

TTC TELEPHONE TERMINAL CABINET

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

UPS UNINTERRUPTED POWER SUPPLY

V VOLT (KV-KILOVOLT)

VA/R VOLT-AMPS/REACTIVE

VM VOLT METER

W WATTS

W/ WITH

WH WATTHOUR METER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFMR SW TRANSFER SWITCH

XP EXPLOSION PROOF

1P SINGLE-PHASE

2P TWO-POLE

3P THREE-POLE

4P FOUR-POLE

Ø PHASE

DESCRIPTION ABBREV. DESCRIPTION

ABBREVIATIONS INDEX

IFC INTERNATIONAL FIRE CADE

E1 SYMBOLS, SCHEDULES AND NOTES

E2.1 JORDAN HILLS ELEMENTARY - POWER PLAN

E2.2 RIVERSIDE ELEMENTARY - POWER PLAN

E2.3 TERRA LINDA ELEMENTARY - POWER PLAN

E2.4 WELBY ELEMENTARY - POWER PLAN

E2.5 WESTVALE ELEMENTARY - POWER PLAN

E2.6 ELK RIDGE MIDDLE SCHOOL - POWER PLAN

E2.7 JOEL P JENSEN MIDDLE SCHOOL - POWER PLAN

E2.8 SOUTH VALLEY SCHOOL - POWER PLAN

E2.9 AUXILIARY SERVICES BUILDING - POWER PLAN

E2.10 JATC NORTH BUILDING 1 - POWER PLAN LEVEL 1

E2.11 JATC NORTH BUILDING 1 - POWER PLAN LEVEL 2

E2.12 JATC NORTH BUILDING 2 - POWER PLAN LEVEL 0

E2.13 JATC NORTH BUILDING 2 - POWER PLAN LEVEL 1

E2.14 JATC NORTH BUILDING 2 - POWER PLAN LEVEL 2

E2.15 JATC NORTH BUILDING 2 - POWER PLAN LEVEL 3

INDEX OF ELECTRICAL DRAWINGS

TYPICAL RACEWAY SUPPORT METHODS

NTS

STRUCTURAL UNIT

CONDUIT HANGER

RACEWAY - 3/4" THRU 6"

H003DIAGRAM

NUTS

FLAT WASHER

1/4" STEEL PLATE

NUT

FLAT WASHER

1/4" STEEL PLATE

ALL THREAD ROD

SIZE AS REQUIRED

ALL THREAD - SIZE AS

REQUIRED (3/8" MINIMUM)

TRANSFORMER WALL MOUNTING

USE MANUFACTURERS STANDARD WALL

BRACKET

SECURE TO WALL WITH EXPANSION

ANCHOR BOLTS, SIZES AND TYPES TO

COMPLY WITH REQUIREMENTS OF SPEC

SECTION 16071.

NOTE:

RUBBER DISK

NEOPRENE

FOUR CORNERS

TYPICAL OF ALL

VIEW A

BRACKET

DRY TYPE VENTILATED

TRANSFORMER

EXPANSION ANCHOR BOLT

(TYP.)

'A'

Q002DIAGRAM

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E1

SYMBOLS,

SCHEDULES

AND NOTES

ID

F-

G

YM

MDF-LMC

EXISTING PANEL 'E'

E2

IDF-STO

E1

NEW LOAD CENTER 'EE'

(PANEL 'E' EXTENSION)

E3

EE-8

EE-6

EE-4

EE-2

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.1

JORDAN HILLS

ELEMENTARY

POWER PLAN

JO

R

D

AN

H

IL

LS

E

LE

M

EN

TA

R Y, SO

U

TH

W

ES

T, W

ES

T

JO

R D

AN

, U

TA

H

E1 CHANGE OUT THE TWO DUPLEX RECEPTACLES IN THE EXISTING 4-PLEX RECEPTACLE AT MDF-LMC TO RED RECEPTACLES. ADD THREE ADDITIONAL 4-PLEX RECEPTACLES. REWIRE THE EXISTING 4-PLEX AS REQUIRED TO CONNECT TO ONE EXISTING CIRCUIT AND ONE NEW 4-PLEX TO THE OTHER EXISTING CIRCUIT (VERIFY

CIRCUITS). CONNECT THE OTHER TWO NEW 4-PLEX RECEPTACLES TO CIRCUITS AS SHOWN.

E2 CHANGE OUT THE TWO DUPLEX RECEPTACLES IN THE EXISTING 4-PLEX RECEPTACLE AT IDF-GYM TO RED RECEPTACLES. ADD AN ADDITIONAL 4-PLEX. REWIRE THE EXISTING 4-PLEX AS REQUIRED TO CONNECT TO ONE EXISTING CIRCUIT AND THE NEW 4-PLEX TO THE OTHER EXISTING CIRCUIT. VERIFY THE EXISTING CIRCUITS.

E3 PROVIDE A LOAD CENTER 'EE' (EXTENSION TO PANEL 'E') ADJACENT TO PANEL 'E'. REMOVE (3) SINGLE POLE BREAKERS FROM EXISTING PANEL 'E' AND RE-INSTALL THEM IN THE NEW 'EE'. PROVIDE A 50A/3P CIRCUIT BREAKER IN THE ABANDONED SPACES IN 'E'. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY IN 'E' AND

COMPATIBILITY OF 'EE' WITH THE EXISTING BREAKERS.

SHEET KEYNOTES

POWER PLAN

1/16" = 1'-0" 0 8' 16' 32'

PROVIDE (4) #6 THWN

AND (1) #8 GRND,

IN 1" CONDUIT

FE

FE

FEFE

FE

FE

VEST

CHILLER

CONF

BOILER

C O

R R

ID

O R

CLASSROOM

CORRIDOR

C O

R R

ID

O R

C O

R R

ID

O R

M

C O

R R

ID

O R

M

C O

R R

ID

O R

U

C O

R R

ID

O R

L8

C O

R R

ID

O R

L8

C O

R R

ID

O R

U

C O

R R

ID

O R

U

CORRIDOR

M9

CORRIDOR

M8

CORRIDOR

U8

CORRIDOR

U8

CORRIDOR

L9

CORRIDOR

L8

LO

B B Y

CLASSROOM

M4

CLASSROOM

CLASSROOM

M5

CLASSROOM

M6 CLASSROOM

M1

CLASSROOM

M2

CLASSROOM

M3

CLASSROOM

116A

CLASSROOM

116B

CLASSROOM

CLASSROOM

MEDIA

CENTER

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

L5

CLASSROOM

L6

CLASSROOM

L1

CLASSROOM

L4

CLASSROOM

L2

CLASSROOM

L3

CLASSROOM

U1

CLASSROOM

U2

CLASSROOM

U6

COMPUTER

ROOM

CLASSROOM

U3

CLASSROOM

U4

CLASSROOM

U5

RESOURCE

RESOURCE

STORAGE

U12

STORAGE

U11

BOYS GIRLS

PREP

U7

STORAGE

U10

BOYS GIRLS

BOYS

GIRLS

PREP

L7

STORAGE

L10

STORAGE

L11

STORAGE

M11

PREP

M7

STORAGE

M10

BOYS

GIRLS

BOYS

GIRLS

KINDERGARTEN

KINDERGARTEN

TEACHER

LOUNGE

PRINCIPAL

STORAGE

MAIN

OFFICE

OFFICE

RR

HEALTH

CUST

RR

STORAGE

M12

CORRIDOR

MEN

WOMEN

STORAGE

KITCHEN

LUNCH ROOM

STORAGE

OFF

CUST

KINDERGARTEN

PLAY AREA

BOYS

GIRLS

OFFICE

IDF-OFC

MDF-LMC

IDF-STO

EM-20,22

EM-25 EM-27

EM-24

E1

EXISTING PANEL 'EM'

E2

E3

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.2

RIVERSIDE

ELEMENTARY

POWER PLAN

R

IV

ER

SI

D E

EL

EM

EN

TA

R Y, SO

U

TH

W

ES

T, W

ES

T

JO

R D

AN

, U

TA

H

E1 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACE 24 IN PANEL 'EM'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEX TO A 20A CIRCUIT BREAKER AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILTY.

E2 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 25,27 IN PANEL 'EM'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY.

E3 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 20,22 IN PANEL 'EM'. PROVIDE CONDUIT AND WIRE FROM EACH DUPLEX IN THE NEW 4-PLEX TO 20A CIRCUIT BREAKERS A SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

SHEET KEYNOTES

POWER PLAN

1/16" = 1'-0" 0 8' 16' 32'

DRY

STORAGE

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

MEDIA

CENTER

CLASSROOM

CLASSROOM

MULTI-PURPOSE ROOM

MUSIC

STORAGE

STOR

OFFICE

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

STORAGE

BOYS

GIRLS

MECHANICAL

ELEC

LOCKERS

LAUNDRY

CLASSROOM

CLASSROOM

CLASSROOM

PREP

NE

GIRLS

NE

BOYS

PREP

CLASSROOM

CLASSROOM

CLASSROOM

CORRIDOR

CLASSROOM

STORAGE

CORRIDOR

CLASSROOM

SW

GIRLS

SW

BOYS

PREP

PREP

NE

BOYS

NE

GIRLS

PREP

PREP

KILN

RESOURCE

CLASSROOM

PREP

CORRIDOR

TEACHER'S

WORK ROOM

CORRIDOR

WALK-IN

FREEZER

STORAGE

JANITOR

STORAGE

STORAGE

STORAGE

STORAGE

GAS

METER

CORRIDOR

CORRIDOR

CORRIDOR

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

CORRIDOR

CORRIDOR

ROOM

MDF-LMC

EE-2,4

E2

E1

NEW LOAD CENTER 'EE'

(PANEL 'E' EXTENSION)

EXISTING PANEL 'E'

EE-6,8

E1

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.3

TERRA LINDA

ELEMENTARY

POWER PLAN

TE

R

R A

LI

N

D A

EL

EM

EN

TA

R Y, W

ES

T

O

LD

B

IN

G H

AM

H

W Y, W

ES

T

JO

R D

AN

, U

TA

H

E1 PROVIDE A LOAD CENTER 'EE' (EXTENSION TO PANEL 'E') ADJACENT TO PANEL 'E'. REMOVE (3) SINGLE POLE BREAKERS FROM EXISTING PANEL 'E' AND RE-INSTALL THEM IN THE NEW 'EE'. PROVIDE A 50A/3P CIRCUIT BREAKER IN THE ABANDONED SPACES IN 'E'. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY IN 'E' AND

COMPATIBILITY OF 'EE' WITH THE EXISTING BREAKERS.

E2 PROVIDE CONDUIT AND WIRE FROM EACH NEW 4-PLEX TO CIRCUIT BREAKERS AS SHOWN.

SHEET KEYNOTES

POWER PLAN

1/16" = 1'-0" 0 8' 16' 32'

(4) #6 THWN AND (1) #8 GND.

IN 1" CONDUIT

MDF-LMC

EXISTING PANEL 'EM'

EM-22

EM-24

J

H

G

F

E

D

C

B

A

12344.855.26789 2.1

B.7

C.9

MEDIA CENTER

CLASSROOM (20)

CLASSROOM (19)

MEDIA SUPPORT

MEDIA WORK

ROOM

MEDIA STORAGE

OFFICE

OFFICE

STORAGE

ROOF ACCESS

MEDIA CLASSROOM

CLASSROOM (2)

COMPUTER LAB

CLASSROOM (3)

CLASSROOM (5)

CLASSROOM (6)

CLASSROOM (1)

CLASSROOM (4)

BOYS

GIRLS

TEACHERS LOUNGE

JAN.

BOYS

GIRLS

STORAGE

STORAGE

CLASSROOM (7)

CLASSROOM (8)

CLASSROOM (9)

CLASSROOM (10)

CLASSROOM (11)

CLASSROOM (12)

CLASSROOM (13)

CLASSROOM (14)

117 CLASSROOM (17)

CLASSROOM (18)

CLASSROOM (16)

CLASSROOM (15)

KINDERGARTEN

CLASSROOM

KINDERGARTEN

CLASSROOM

CLASSROOM (21)

CLASSROOM (22)

CLASSROOM (25)

CLASSROOM (26)

CLASSROOM (24)

CLASSROOM (23)

STORAGE

STORAGE

BOYS

GIRLS

GIRLS

BOYS

JAN.

TEACHER WORK

ROOM

GIRLS

BOYS

TEACHER WORK

ROOM

JAN.

GIRLS

BOYS

STORAGE

STORAGE

PLAY ROOM

LUNCH ROOM

STORAGE

KITCHEN

OFFICE

034UTILITY

KITCHEN STORAGE

WOMEN

MEN

WATER HEATER

WASH ROOM

JANITOR STORAGE

STORAGE

CHAIR AND PLAY

STORAGE

COMPUTER LAB

JAN OFFICE

MECH

MECH

TEACHER LOUNGE

RESTROOM

RESTROOM

CUSTODIAN

RESTROOM

008A

HEALTH

MAIN OFFICE

MAILBOX STORAGE

004A

PRINCIPAL OFFICE

LOBBY

MAIN HALLWAY

LOOP

EAST HALLWAY

LOOP

STORAGE

013A

STORAGE

013B

NORTH HALLWAY

LOOP

PLAY ROOM

HALLWAY

LUNCH ROOM

HALLWAY

SOUTH HALLWAY

LOOP

KINDERGARTEN

HALLWAY

020C

BOYS

109A

GIRLS

108A

UTILITY HALLWAY

OFFICE HALLWAY

MAIN ENTRY

VESTIBULE

001ASTORAGE

001B

VESTIBULE

020A

VESTIBULE

020B

VESTIBULE

020E

KITCHEN HALLWAY

VESTIBULE

050A

VESTIBULE

050B

VESTIBULE

060A

VESTIBULE

060B

VESTIBULE

070A

VESTIBULE

070B

MECH

COUNSEL

STORAGE

E1

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.4

WELBY

ELEMENTARY

POWER PLAN

W

EL

BY

E

LE

M

EN

TA

R Y, W

ES

T

S O

U

TH

, S O

U

TH

J O

R D

AN

, U

TA

H

E1 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 22 AND 24 IN PANEL 'EM'. PROVIDE CONDUIT AND WIRE FROM EACH 4-PLEX TO A 20A CIRCUIT BREAKER AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY.

SHEET KEYNOTES

MDF-STO

IDF-C3

EXISTING PANEL 'EL'

EL-13

EL-15

E1

EL-14

EL-16

E2

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.5

WESTVALE

ELEMENTARY

POWER PLAN

W

ES

TV

AL

E

EL

EM

EN

TA

R

Y, G

AR

D N

ER

L

AN

E, W

ES

T

JO

R D

AN

, U

TA

H

E1 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 13 AND 15 IN PANEL 'EL'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

E2 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 14 AND 16 IN PANEL 'EL'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

SHEET KEYNOTES

DN

UP

DRAMA

C104

DANCE / FITNESS

C101

STORAGE

C105

STORAGE

C102

CLASSROOM

D101

GROUP ROOM

A121

STORAGE

A128

FLEX SPACE

A127

CAMERA

A129STORAGE

A120

COUNSELING

A119 ATTENDANCE

A124

SICK ROOM

A125

RESTROOM

A122

RESTROOM

A126

STORAGE

A104

COUNSELOR

A118

COUNSELOR

A115

COUNSELOR

A114

PSYCHOLOGIST

A117

OFFICE

A106

SRO

A105

COUNSELOR

A113

PRINCIPAL

A110

VICE PRINCIPAL

A109

VICE PRINCIPAL

A108

CONFERENCE

A107

MAIN OFFICE

A102

COPY/ MAIL

A103

HALL

A112

RESTROOM

A130

ENTRY

B101

EL: 100' - 1 1/2"

CLASSROOM

E138

CLASSROOM

E137

CLASSROOM

E135

CLASSROOM

E136

TEACH PREP

E132

TEACH PREP

E133

BOYS

E134

CLASSROOM

E127

CLASSROOM

E128

CLASSROOM

E126

CLASSROOM

E125

CORRIDOR

E101

CORRIDOR

E121

CORRIDOR

E131

CORRIDOR

E108

ART STOR/ KILN

E141

ART

E139

ART

E140

VEST.

E100

VEST

E130

STOR

D123

EQUIP

D127

TEACH PREP

D125

RUBBISH

D126

OPEN

D128

CAFETERIA

D157

TEACH LOUNGE

D104

GIRLS

D152

BOYS

D153

STOR

D124

CORRIDOR

D161

KITCHEN

D130

FRZZ

D131

REFR

D132

OFF

D133

L D134

DRY STOR

D135

FOOD COURT

D141

SERV

D143

SERV

D142

J.

D136 BREAK

D137 T.

D138

VEST.

D100

STO

D113

CORRIDOR

D121

GIRLS LOCKERS

C110

BOYS LOCKERS

C130

OFFICE

C128

OFFICE

C109

LAV

C128A

LAV

C109A

TOILET

C108

TOILET

C127

STO

C126

JAN

C129

STO

C107

GIRLS

D164

BOYS

D165

JAN

C111

CORRIDOR

C139

CORRIDOR

C138

GYMNASIUM

C136

AUDITORIUM

B109

STORAGE

B103

VEST.

B110

CORRIDOR

B111

CORRIDOR

B106

B B102

E B104

B.

B105

CORRIDOR

B112

CLASSROOM

A149

CLASSROOM

A148

CLASSROOM

A146

CLASSROOM

A147CLASSROOM

A136

CLASSROOM

A139

CLASSROOM

A138

CLASSROOM

A137

CORRIDOR

A165

TEACH PREP

A134

TEACH PREP

A135

VEST.

A130B

BOYS

A167

GIRLS

A168

CORRIDOR

A169

CLASSROOM

A143

CLASSROOM

A142

CORRIDOR

A157

CLASSROOM

A156 CLASSROOM

A155

TEACH PREP

A150

TEACH PREP

A151 GIRLS

A153

JAN

A152

CLASSROOM

E123 CLASSROOM

E122

CLASSROOM

E118

CLASSROOM

E119

LAB

E117

SMART LAB 2000

E107

GIRLS

E114J.

E113

LECTURE

E104OFF/STO

E106

OFF/STO

E103

A/V E105

TLC LAB 2000

E102

ART STOR/ KILN

E142

CHASE

E143

CHASE

E144

JAN

F156

PRACT

A164

SCIENCE

F113

SCIENCE

F115

SCIENCE

F112

SCIENCE

F116

SCIENCE

F114

J.

C106

J C132

JAN OFFICE

C133

STO

C134

BOYS

D106

GIRLS

D107

CONF

F145

TEACH PREP

F142

AV STOR

F143

CAREER

F144

MEDIA WORK

F152

PERIOD

F153

TEACH WORK

F149

CLASSROOM

F148

FOODS

F106

STOR

F105

PANTRY

F104

CLASSROOM

F135

CLASSROOM

F134 CLASSROOM

F133

CLASSROOM

F136

TEACH PREP

F128

TEACH PREP

F137

CLASSROOM

F124

CLASSROOM

F123

CLASSROOM

F122

CLASSROOM

F125

CLASSROOM

A145CLASSROOM

A144

STO

C137

JAN

F126

CHASE

D124

CLASSROOM

A159

CLASSROOM

A158

VEST.

E120

VEST.

F140

VEST.

F130

VEST.

A170

VEST.

A166

VEST.

A100

VEST.

D120

CHORAL

A161

STO

C135

OFFICE

F151

MEDIA CENTER

F146

CLASSROOM

F107

STOR

F103

SEWING

F102

BAND

A160

PRACT STOR

A162

PRACT

A163

CORRIDOR

F141

BOYS

F154

GIRLS

F155

CORRIDOR

F111

BOYS

A154

CORRIDOR

F131

GIRLS

F127

CORRIDOR

F121

CORRIDOR

A101

HALL

D167

STOR

B107

CORRIDOR

F101

CORRIDOR

C121

ELECTRICAL

C103

IDF-102n

EM3-9EM3-7

IDF-712

EM2-8

EM3-11

IDF-711aa

EM3-6

EM3-4

MDF-COPY

EM3-5

EM2-40

EM3-2

E4

E2

IDF-KIT MOUNTED

ABOVE THE UPPER

CABINET

NEW TRANSFORMER 'TX-EM3'

NEW PANEL 'EM3'

EXISTING PANEL 'EM2'

EXISTING PANEL 'EH'

E1

IDF-218

EM3-3EM3-1

E3

NEW TRANSFORMER 'TX-EM3'

'EL2'

E1

EXISTING TRANSFER SWITCH

'EM'

'EM2'

'EH'

EXISTING TRANSFORMER

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.6

ELK RIDGE

MIDDLE

SCHOOL

POWER PLAN

EL

K

R

ID

G E

M

ID

D

LE

S C

H O

O L, W

ES

T

S O

U

TH

, S O

U

TH

J O

R D

AN

, U

TA

H

POWER PLAN

1" = 20'-0" 0 10' 20' 40'

E1 PROVIDE A 30A/3P CIRCUIT BREAKER IN EXISTING PANEL 'EH'. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY IN 'EH'. REFER TO ONE-LINE DIAGRAM FOR FEEDER SIZING. MOUNT TRANSFORMER ON WALL

ABOVE EXISTING TRANSFORMER. SEE DIAGRAM Q002/E1.

E2 PROVIDE THE NEW DUPLEX IN THE JUNCTION BOX SUPPLIED INSIDE THE IDF CABINET.

E3 CHANGE OUT THE DUPLEX RECEPTACLES IN THE EXISTING (2) 4-PLEX RECEPTACLES TO RED DEVICES AND RECONNECT ONE TO EXISTING CIRCUIT (EM2-40 (VERFIY)), THE OTHER ONE TO CIRCUIT BREAKER AS SHOWN.

E4 CHANGE OUT THE DUPLEX RECEPTACLES IN THE EXISTING (2) 4-PLEX RECEPTACLES TO RED DEVICES AND RECONNECT ONE TO EXISTING CIRCUIT (EM2-8 (VERIFY)), THE OTHER ONE TO CIRCUIT BREAKER AS SHOWN.

SHEET KEYNOTES

2 3

A

B

D

F

G

E

C

GYM

A-41

CAFETERIA

B-14

STORAGE

B-13

STORAGE

B-12

DRY FOOD

STORAGE

B-32

SCULLERY

B-33

KITCHEN

B-39

REC'G

B-11

CAN WASH

B-30

TECH LAB

C-15

CLASSROOM

C-4

MECHANICAL YARD

WOODSHOP

C-7

CLASSROOM

C-2

CLASSROOM

C-1

CLASSROOM

C-3

CLASSROOM

C-27

CLASSROOM

C-24 CLASSROOM

C-25

CLASSROOM

C-26

CLASSROOM

C-21

CLASSROOM

C-23

CORRIDOR

C-23B

WEIGHT ROOM

C-22

CORRIDOR

C-22

MEDIA CENTER

D-13

CLASSROOM

D-42

CLASSROOM

D-43

CLASSROOM

D-33

CLASSROOM

D-32

CLASSROOM

D-14

CLASSROOM

D-20

CLASSROOM

D-21 CLASSROOM

B-20

CLASSROOM

B-19

STORAGE

B-44

EQUIPMENT

STORAGE

B-27

STORAGE

B-26

AUDITORIUM

A-49

CLASSROOM

D-27

CLASSROOM

D-28

CLASSROOM

D-24

CLASSROOM

D-25

CLASSROOM

D-23

CLASSROOM

D-22

CORRIDOR

B-3

VENDING

B-43

FACULTY ROOM

B-17

CLASSROOM

D-44

CLASSROOM

D-41

CLASSROOM

D-40

CLASSROOM

D-31

CLASSROOM

E-13

CORRIDOR

D-30

CLASSROOM

E-2

CLASSROOM

E-1

CLASSROOM

E-4

CLASSROOM

E-3

CLASSROOM

E-11

CLASSROOM

E-12

CLASSROOM

E-14

CLASSROOM

E-20

TEACH PREP

E-15

TEACH PREP

E-16

TEACH PREP

E-7

LAV

E-5

CLASSROOM

E-36

CLASSROOM

STORAGE

CLASSROOM

E-21

CLASSROOM

E-23

CLASSROOM

E-22

ATTENDANCE

WAITING

LOBBY

MECHANICAL

A-57

STORAGE

A-55

GIRLS LOCKER

ROOM

A-39

JANITOR

B-7

BOYS LOCKER ROOM

A-22

CHORAL

DIRECTOR

STORAGE

PRACTICE

PRACTICE

BAND

STORAGE

A-36

INSTRUMENTAL

STOR

STORAGE

A-19

STORAGE

STORAGE

SHOWERS

A-35

SHOWERS

A-20

DATA ROOM

139A

IDF-508a

EM2-10EM2-8

E1

EXISTING

PANEL 'EM2'

MDF-MC3

EM2-12

E2

IDF-112a

EM2-53

E3

IDF-060e

EM2-53

E4

EM2-51

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.7

JOEL P JENSEN

MIDDLE

SCHOOL

POWER PLAN

JO

EL

P J

EN

SE

N M

ID

D

LE

S

C H

O O

L, SO

U

TH

W

ES

T, W

ES

T

JO

R

D

AN

, U

TA

H

E1 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 8 AND 10 IN PANEL 'EM2'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

E2 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACE 12 IN PANEL 'EM2'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY.

E3 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACE 52 IN PANEL 'EM2'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY.

E4 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 51 AND 53 IN PANEL 'EM2'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

SHEET KEYNOTES

1" = 20'-0" 0 10' 20' 40'

3.8

A B C D E F G H J K L M M.1 N P R S

3.8

B.3 K.3

2.8

EXISTING PANEL 'EL'

MDF

EL-33,35 EL-34,36

E1

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.8

SOUTH VALLEY

SCHOOL

POWER PLAN

LEVEL 1

SO

U

TH

V

AL

LE

Y

SC

H O

O L, SO

U

TH

R

ED

W O

O D

R D

W

ES

T

JO

R

D

AN

, U

TA

H

E1 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 33, 34, 35 and 36 IN PANEL 'EL'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

SHEET KEYNOTES

POWER PLAN LEVEL 1

DN

UP

UP

DN

UP UP

12P3456C

OFFICE

N 120

KITCHEN

N 119

LOBBY

N 115

PANTRY

N 117AV

N 118

TRAINING RM.

N 116

STORAGE

N 112

MENS

N 111

WOMENS

N 109

STORAGE

N 105

NUTRITION

OFFICE

N 102

NUTRITION

NUTRITION

N 101

HALL

N 106

ROOM

N 107

TRAINING

RECEPTION

N 100

WOMENS

N 156

MENS

N 155

ROOM

N 161

TRAINING

HALLWAY

N 159

OFFICE

N 168

MAINTENANCE

STORAGE

N 164

CUSTODIAL

SERVICES

OFFICE

N 165

ENERGY

AND UTILITIES

DIRECTOR

N 179

AUXILLARY

DIRECTOR

N 174

AUXILLARY

ASSISTANT

ROOM

N 173

AUXILLARY

CONFERENCE

STORAGE

N 176

SAFE ROOM

N 177

AUXILLARY

STORAGE

N 180

BOARD CONFERENCE

N 182

WOMENS

N 186

MENS

N 187

WOMENS

N 198

BOARD ROOM

N 188

AUXILLARY

N 175

WAITING

N 172

RECEPTION /

LOUNGE

N 207

EMPLOYEE

HALL

N 208

TESTING

N 209

OPEN OFFICE

N 217

ED SUPPORT

N 195

OFFICE

N 200

ED SUPPORT

OFFICE

N 201

ED SUPPORT

OFFICE

N 202

ED SUPPORT

OFFICE

N 203

ED SUPPORT

SPECIALIST

N 204

TEACHER

(A & PS)

N 213

DIRECTOR

ROOM

N 211

CONFERENCE

ROOM

N 210

DATA ANALYSIS

OPEN OFFICE

N 206

OFFICE

N 215

INTERVENTION

N 214

STUDENT

WORKROOM

S 116

STORAGE

S 115

HEARING

SUPPORT

S 133

INSTRUCTIONAL

SUPPORT

S 132

INSTRUCTIONAL

STORAGE

S 112

MOTOR DEV

OFFICE

S 110

ALS

STORAGE

S 111

VISUAL

IMPAIRED

ENTRY

S 107

SPACE

S 119

OPEN

HALL

S 130

RECEPTION

S 127

ISS

S 125

OFFICE

S 124

GUIDANCE

SUPPORT

S 131

INSTRUCTIONAL

STORAGE

S 121

CUSTODIAL

CUSTODIAL

S 122

ROOM

S 123

CONFERENCE

STORAGE

S 118

MEDIA

WAREHOUSE

S 167

SURPLUS

WAREHOUSE

S 165

FOOD

MAIL ROOM

S 151

CORRIDOR

S 138

ELECTRICAL

S 149

INFO TECH

S 148

ROOM

S 144

CONFERENCE

PURCHASING

S 142

REPAIR

S 139

COMPUTER

STORAGE

S 150

GUIDANCE

HALL

N 167

HALL

N 169

HALL

N 183

CO

RR

ID

OR

N

HALL

N 185

HALL

N 199

CUSTODIAL WAREHOUSE

S 178

RECEIVING

S 171

PRINTING STORAGE

S 164

FIRE RISER

S 179

MENS

N 196

TESTING OFFICE

N 212

VESTIBULE

S 108

VESTIBULE

S 126

PRINTING

S 134

STORAGE

S 139A

COMPUTER

CORRIDOR

S 152

CLOSET

JANITOR

HALL

S 135

JANITOR

N 197

STORAGE

S 113

MOTOR DEV

STORAGE

S 114

UAAACT

STORAGE

S 129

ISS

CONFERENCE

S 141

LAB

S 120

COMPUTER

STORAGE

N 170

MAINTENANCE

ROOM

N 160

TRAINING

CLASSROOM

N 127

CLASSROOM

N 128

CLASSROOM

N 129

STORAGE

N 166

ENERGY

AND UTILITIES

OFFICE

N 163

CUSTODIAL

SERVICES

BREAK

N 158

COPY/

OFFICE

N 132

STORAGE

N 134

CONFERENCE

N 135

ALARMS

S 101

MDF

N 181

OFFICE

S 177

BAY

S 168

CHARGING

W

OM

EN

S

N

ME

NS

N

WOMENS

S 136

MENS

S 137

CLOSET

S 153

JANITOR

CRIB

S174

TOOL

JANITOR

S175

UNISEX

S 176

STORAGE

S 117

COMP ROOM

N 104

NUTRITION

HALLWAY

N 205

HALLWAY

N 216

WAITING

N 136

OPEN OFFICE

N 133

PREFUNCTION

N 125

HALLWAY

N 139

HALLWAY

N 147

OPEN OFFICE

N 144

WAREHOUSE

N 146

MAINTENANCE

OFFICE/STORAGE

N 141

MAINTENANCE

HALLWAY

N 126

OPEN OFFICE

N 157

OPEN OFFICE

N 162

OPEN OFFICE

N 171

VESTIBULE

N 143

LOADING DOCK

N 142

HALL

N 103

HALLWAY

S104

HA

LL

W

AY

S1

HALLWAY

S105

HALLWAY

S106

SPACE

S 128

OPEN

SPACE

S 140

OPEN

RECEPTION/

S 143

WAITING

CO

RR

ID

OR

S

HALL

S100

LOSS PREVENTION

S102

VESTIBULE

S 145

STORAGE

S 146

CORRIDOR

S 154

CHEMICAL

S 156 COPY

S 158

PAINTING

S 160

BINDING

S 162

CORRIDOR

S 155

SEC / WAITING

S 163

DIRECTOR

S 161

GRAPHICS

S 159

BREAK

S 157

WAREHOUSE

S 167

SURPLUS

CORRIDOR

S 170

CORRIDOR

S 172

CORRIDOR

S 169

CORRIDOR

S 173

CLASSROOM

N 140

COPY

N 178

IDF

N 114

STORAGE

N 113

HALL

N 108

HALL

N 130

PLAN ROOM

N 131

HALL

N 138

HALL

N 137

LAUNDRY

N 121

STORAGE

S 180

RECORDS

TOOL CRIB

N 150

CPT ROOM

S 166

BAY

N 151

CHARGING

STORAGE

136A

VESTIBULE

N 190

IDF-A109c

IDF-207 ON

SECOND FLOOREL1-26

E5

EXISTING PANEL 'EL1'

IDF-136cEL1-20,22

E4

M

DF

EL1-21

E3

EL1-25

IDF-B111a ON

SECOND FLOOR

E2

E1

EXISTING PANEL 'ESL3'

EL1-19EL1-23

EL1-24

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.9

AUXILIARY

SERVICES

BUILDING

POWER PLAN

AU

XI

LI

AR

Y

SE

R

VI

C

ES

B U

IL

D

IN

G

, 7

SO

U

TH

R

ED

W O

O D

R D

, W

ES

T

JO

R D

AN

, U

TA

H

E1 CHANGE THE TWO EXISTING DUPLEX RECEPTACLES TO A 4-PLEX RECEPTACLE WITH RED DUPLEX RECEPTACLES. RECONNECT THE EXISTING 2 CIRCUITS TO THE RECEPTACLES, ONE CIRCUIT TO EACH 4-PLEX.

PROVIDE 1 NEW 20A/1P CIRCUIT BREAKER IN PANEL 'ESL3' AND PROVIDE CONDUIT AND WIRE TO A SECOND

4-PLEX, CONNECTED TO THE NEW CIRCUIT.

E2 PROVIDE A 20A/1P CIRCUIT BREAKER AT TWO AVAILABLE SPACES IN PANEL 'ESL3'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

E3 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 19, 21, 23 AND 25 IN PANEL 'EL1'. PROVIDE CONDUIT AND WIRE FROM EACH NEW 4-PLEX TO A 20A CIRCUIT BREAKER AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

E4 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 20 AND 22 IN PANEL 'EL1'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

E5 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 24 AND 26 IN PANEL 'EL1'. PROVIDE CONDUIT AND WIRE FROM NEW 4-PLEXES TO A 20A CIRCUIT BREAKERS AS SHOWN. VERIFY ALL REQUIREMENTS FOR PANEL

COMPATIBILITY.

SHEET KEYNOTES

1" = 30'-0" 0 15' 30' 60'

TEACHER

LOUNGE

VENDING

SAFE

MEN'S

WOMEN'S

CONFERENCE

ROOM

106A

ROOM

VESTIBULE

WORK

ROOM

OFFICE

STORAGE

PHARMACY

STAIR #2

CLASSROOM

PHARMACY

CORRIDOR

ELECTRICALTEL/COMP

ROOM

135 136

ROOM

OFFICE

PHARM.

OFFICE

JANITOR

OFFICE

RECEPTION

PRINCIPAL

LOBBY

ASSIST. PRINCIPAL

OFFICE

STAIR #3

VESTIBULE

RESTROOM

WOMEN'S RESTROOM

MEN'S

CLASSROOM

VETERINARY

SURGERY

X-RAY

VETERINARY

LABORATORY

STAIR #1

ED-NET

CLASSROOM

ED-NET

COMPUTER

CLASSROOM

ED-NET

ED-NET

COMPUTER

ED-NET

OFFICE

LARGE ANIMAL

120 127

STORAGE

LIVE FOOD

DRESSING

OFFICE

VET.

FOOD

STORAGE

LRG. ANIMAL

ROOM

130A

130B

ROOM

DRESSING

122 126A

STOR.

ROOM

BIRD

ROOM

WORK

DELIVERY

FELINE

ROOM

ROOM

CANINE

EXISTING PANEL 'EL0'

ON LOWER LEVEL

E1

E2 E3

EXISTING IDF B003

ON LOWER LEVEL

E4

E4

ELO-9,25

ELO-24

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.10

JATC NORTH

BUILDING 1

POWER PLAN

LEVEL 1

JA

TC

N O

R

TH

B U

IL

D

IN

G

, 9

SO

U

TH

W

IG

H

TS

F

O R

T R

D , W

ES

T

JO

R

D

AN

, U

TA

H

E1 ONE 4-PLEX RECEPTACLE IS EXISTING WITH RED DEVICES. VERIFY EXISTING CIRCUIT IN 'EL0'.

E2 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACE 24 IN PANEL 'EL0'. PROVIDE CONDUIT AND WIRE FROM 4-PLEX

TO A 20A CIRCUIT BREAKER. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY.

E3 CHANGE OUT THE DUPLEX RECEPTACLES IN THE EXISTING 4-PLEX RECEPTACLE TO RED DEVICES AND

RECONNECT TO EXISTING CIRCUITS (EL-09,25 (VERIFY)).

E4 VERIFY THE LOCATION OF THE DATA CLOSET AND PANELBOARD 'EL0' ON THE FLOOR LEVEL BELOW.

SHEET KEYNOTES

POWER PLAN LEVEL 1

1/8" = 1'-0" 0 4' 8' 16'

RESTROOM

STAIR #3

COMPUTER

MEDICAL

CLASSROOM

MEDICAL

RECEPTION

MEDICAL

STORAGE

MEDICAL

LABORATORY

MEDICAL

EXAM

MEDICAL

COMP LAB

BIO-TECH

STORAGE

227A

LIBRARY

BIO-TECH

COMMONS

OFFICE

MEDICAL

ROOM

TEL/COM

ROOM

ELECTICAL

OFFICE

BIO-TECH

LABORATORY

BIO-TECH

PREP ROOM

BIO-TECH

PREP ROOM

BIO-TECH

STAIR 4

CORRIDOR

STAIR #1

225CLASSROOM

BIO-TECH

JANITOR

OFFICE

DENTAL

LABORATORY

DENTAL

RESTROOM

WOMEN'S

RESTROOM

MEN'S

COMPUTER AREA

OPERATORY

DENTAL

LABORATORY

PHYSICAL THERAPY

MEN'S

WOMEN'S

219 STORAGE

PHYSICAL THERAPY

OFFICE

PHYSICAL THERAPY

STORAGE

DENTAL

ROOMS

DRESSING

WHIRLPOOL

IDF-208

E1

ELO-28

ELO-26

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.11

JATC NORTH

BUILDING 1

POWER PLAN

LEVEL 2

E1 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 26 AND 28 IN PANEL 'EL0'. PROVIDE CONDUIT AND WIRE FROM EACH 4-PLEX TO A 20A CIRCUIT BREAKER. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY. VERIFY THE

LOCATION OF PANELBOARD 'EL0' ON LOWER LEVEL.

SHEET KEYNOTES

POWER PLAN LEVEL 2

1/8" = 1'-0" 0 4' 8' 16'

JA

TC

N O

R

TH

B U

IL

D

IN

G

, 9

SO

U

TH

W

IG

H

TS

F

O R

T R

D , W

ES

T

JO

R

D

AN

, U

TA

H

EXISTING

PANEL 'EL4-SUB'

IDF-B031

E1

IDF-B004

E2

IDF-B012

E3

EL

4-

EL

4-

EL4-15

EL4-13

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.12

JATC NORTH

BUILDING 2

POWER PLAN

LEVEL 0

POWER PLAN LEVEL 0

1/8" = 1'-0" 0 4' 8' 16'

JA

TC

N O

R

TH

B U

IL

D

IN

G

, 9

SO

U

TH

W

IG

H

TS

F

O R

T R

D , W

ES

T

JO

R

D

AN

, U

TA

H

E1 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 9 AND 11 IN PANEL 'EL4-SUB'. PROVIDE CONDUIT AND WIRE FROM EACH 4-PLEX TO A 20A CIRCUIT BREAKER. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY.

E2 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACE 13 IN PANEL 'EL4-SUB'. MOUNT 4-PLEX HIGH ON WALL AT THE BACK OF THE RACK. PROVIDE CONDUIT AND WIRE FROM 4-PLEX TO A 20A CIRCUIT BREAKER. VERIFY ALL

REQUIREMENTS FOR PANEL COMPATIBILITY.

E3 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACE 15 IN PANEL 'EL4-SUB'. MOUNT 4-PLEX HIGH ON WALL AT THE BACK OF THE RACK. PROVIDE CONDUIT AND WIRE FROM 4-PLEX TO A 20A CIRCUIT BREAKER. VERIFY ALL

REQUIREMENTS FOR PANEL COMPATIBILITY.

IDF-125

E2

E1

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.13

JATC NORTH

BUILDING 2

POWER PLAN

LEVEL 1

POWER PLAN LEVEL 1

1/8" = 1'-0" 0 4' 8' 16'

JA

TC

N O

R

TH

B U

IL

D

IN

G

, 9

SO

U

TH

W

IG

H

TS

F

O R

T R

D , W

ES

T

JO

R

D

AN

, U

TA

H

E1 CHANGE OUT THE EXISTING DUPLEX RECEPTACLE TO A NEW 4-PLEX RECEPTACLE WITH RED DEVICES AND RECONNECT TO EXISTING CIRCUIT (VERIFY CIRCUIT IN PANELBOARD 'EL4-SUB', LOCATED IN THE BASEMENT

LEVEL).

E2 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACE 10 IN PANEL 'EL4-SUB'. PROVIDE CONDUIT AND WIRE FROM 4-PLEX TO A 20A CIRCUIT BREAKER. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY. (VERIFY LOCATION

OF PANELBOARD 'EL4-SUB', LOCATED IN THE BASEMENT LEVEL).

IDF-227

E1

EL

4-

EL

4-

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.14

JATC NORTH

BUILDING 2

POWER PLAN

LEVEL 2

POWER PLAN LEVEL 2

1/8" = 1'-0" 0 4' 8' 16'

JA

TC

N O

R

TH

B U

IL

D

IN

G

, 9

SO

U

TH

W

IG

H

TS

F

O R

T R

D , W

ES

T

JO

R

D

AN

, U

TA

H

E1 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACES 12 AND 14 IN PANEL 'EL4-SUB'. PROVIDE CONDUIT AND WIRE FROM EACH 4-PLEX TO A 20A CIRCUIT BREAKER. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY.

(VERIFY LOCATION OF PANELBOARD 'EL4-SUB', LOCATED IN THE BASEMENT LEVEL).

IDF-309

E1

E2

JO

R

D

AN

S C

H O

O L

D

IS

TR

IC

T

EM

ER

G

EN

C

Y

PO

W

ER

T O

IT

C

LO

SE

TS

181 E 5600 S, Murray, UT 84107 | (801) 530-3148 info@resolutgroup.com | resolutgroup.com

BI

D

P

AC

KA

G

E #2

E2.15

JATC NORTH

BUILDING 2

POWER PLAN

LEVEL 3

POWER PLAN LEVEL 3

1/8" = 1'-0" 0 4' 8' 16'

JA

TC

N O

R

TH

B U

IL

D

IN

G

, 9

SO

U

TH

W

IG

H

TS

F

O R

T R

D , W

ES

T

JO

R

D

AN

, U

TA

H

E1 CHANGE OUT THE EXISTING DUPLEX RECEPTACLE TO A NEW 4-PLEX RECEPTACLE WITH RED DEVICES AND RECONNECT TO EXISTING CIRCUIT (VERIFY CIRCUIT IN PANELBOARD 'EL4-SUB', LOCATED IN THE BASEMENT

LEVEL).

E2 PROVIDE A 20A/1P CIRCUIT BREAKER AT SPACE 16 IN PANEL 'EL4-SUB'. MOUNT 4-PLEX HIGH ON WALL AT THE BACK OF THE RACK. PROVIDE CONDUIT AND WIRE FROM 4-PLEX TO A 20A CIRCUIT BREAKER. VERIFY ALL REQUIREMENTS FOR PANEL COMPATIBILITY. (VERIFY LOCATION OF PANELBOARD 'EL4-SUB', LOCATED IN THE

BASEMENT LEVEL).

Sheets and Views
24349-A CVR-Layout1
24349-A E1-Layout1
24349-C E21-Layout1
24349-C E22-Layout1
24349-C E23-Layout1
24349-C E24-Layout1
24349-C E25-Layout1
24349-C E26-Layout1
24349-C E27-Layout1
24349-C E28-Layout1
24349-C E29-Layout1
24349-C E210-Layout1
24349-C E211-Layout1
24349-C E212-Layout1
24349-C E213-Layout1
24349-C E214-Layout1
24349-C E215-Layout1

File details come from the government source that posted it. Updated .