HHS Chicago Federal Backfill - 75_ CD - JCK Drawings 07-01-11.pdf
PDF 43 MB Posted
- Solicitation number
- 47PF0022R0001
About this file
This document announces a solicitation for general construction services for the Health and Human Services Chicago Federal Backfill Project. The General Services Administration seeks a general construction contractor to provide construction and renovation services at the John C. Kluczynski and Ralph H. Metcalfe Federal Buildings in Chicago, Illinois to consolidate approximately 122,389 square feet of leased office space into 52,620 square feet of federal space. Eligible firms must be small businesses. The total estimated construction cost is between $10-20 million. The contract will be a firm fixed-price award. The solicitation package will be available on July 12th and proposals will be due on August 11th. The award is targeted for November 2022 with a 250-day performance period ending no later than October 11th, 2023. Attendance at the pre-proposal conference is recommended to understand project requirements. Interested parties should monitor the System for Award Management website and contact the named contracting officer with any questions.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
GENERAL SERVICES ADMINISTRATION
REGION 5
CLIENT
Tel: +1.312.482.8866
ARCHITECT
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel:
CHICAGO, ILLINOIS 60604 - USA
230 SOUTH DEARBORN
ARUP
CHICAGO, ILLINOIS 60601 - USA
ENGINEER
35 EAST WACKER DRIVE, SUITE 1800
Tel: +1.312.849.5610
CARNOW CONIBEAR & ASSOC
CHICAGO, ILLINOIS 60607 - USA
ENVIRONMENTAL CONSULTANTS
600 WEST VAN BUREN, SUITE 500
Tel: +1.312.782.4486
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
G000
JCK COVER
BS/TS LW/CY
HHS CHICAGO FEDERAL BACKFILL PROJECT
230 SOUTH DEARBORN STREET
CHICAGO, ILLINOIS 60604
JOHN C. KLUCZYNSKI FEDERAL BUILDING
ISSUE FOR
75% CONSTRUCTION DOCUMENTS
July 1, 2022
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
ABBREVIATIONS:
ACT. CEILING TILE
ALUM. ALUMINUM
ANOD. ANODIZED
CMU. CONCRETE MASONRY UNIT
CPT. CARPET PLANKS
CT. PORCELAIN/CERAMIC TILE
E.J. EXPANSION JOINT
ELEV. ELEVATOR
EQP. EQUIPMENT
ES. EXPOSED STRUCTURE
EXP. EXPOSED TO ABOVE
EXIST. EXISTING
F.E.C FIRE EXTINGUISHER CABINET
FP. FACTORY PAINT
FRP. FIBERGLASS REINFORCED PLASTIC
GALV. GALVANIZED
GL GLASS
GYP. BD / GYP.GYPSUM BOARD
HM HOLLOW METAL
JAN. JANITORS CLOSET
LH. LEFT HAND
LHR. LEFT HAND REVERSE
LVT. LUXURY VINYL TILE
MECH. MECHANICAL
MCP. METAL CEILING PANEL
MTL. METAL
NS_VCT NON-STATIC VINYL COMPOSITION TILE
N.I.C. NOT IN CONTRACT
PLAS. PLASTER
PT. PAINT
RB. RUBBER BASE
RM. ROOM
SS STAINLESS STEEL
TERR. TERRAZZO
TYP. TYPICAL
UON. UNLESS OTHERWISE NOTED
WD. WOOD
SYMBOLS:
- SECTION TAG
- ELEVATION TAG
- CALLOUT TAG
- NORTH ARROW
- COLUMN GRID
- ROOM TAG
- DOOR TAGS
- WALL TAG
A101
Ref
A101
1 Ref
R e f
R e f
1 Ref
Room name
1i
Ref
A101
GENERAL PROJECT NOTES:
1. FIELD VERIFY ALL DIMENSIONS PRIOR TO PREPARATION OF SHOP DRAWING SUBMITTALS.
2. DO NOT SCALE DRAWINGS.
3. VERIFY EXISTING FIELD CONDITIONS AND PROMPTLY REPORT ANY DISCREPANCIES FROM
THE DRAWINGS TO THE ARCHITECT.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE BRACING AND BLOCKING WITHIN
PARTITIONS AND CEILINGS RECEIVING MILLWORK, GRAB BARS, HARDRAILS, SHELVING,
MONITORS, SIGNAGE, TOILET ACCESSORIES, FURNITURE HANGER STRIPS, BLINDS,
MARKER BOARDS, ETC.
5. THE CONTRACTOR SHALL COORDINATE FINISHED GYPSUM BOARD PARTITION WITH
DIMENSIONAL INSTALLATION REQUIREMENTS OF EQUIPMENT AND MILLWORK.
6. IN THE CASE OF CONFLICTING REQUIREMENTS, THE MOST STRINGENT SHALL APPLY.
7. ALL SS TO BE TYPE 304 UNLESS NOTED OTHERWISE.
8. ENSURE ALL EXPOSED EXISTING GYP. BD. WALL WITHIN PROJECT (TO REMAIN) RECEIVE
NEW PAINT
9. PROVIDE SILICONE SEALANT JOINTS AT JUNCTION OF ALL PLUMBING FIXTURES &
COUNTERTOPS TO A WALL SURFACE.
10. IN LOCATIONS WHERE EXISTING FIRE PROOFING IS REMOVED, PROVIDE NEW FIRE
PROOFING PER SPECIFICATION 07 8100.
11. IF INTUMESCENT FIRE PROOFING IS NEEDED TO ALLOW FOR CLEARANCE OF MEP ITEMS
BELOW GIRDERS, THEN PROVIDE CAFCO SPRAYFILM WB5 OR WB7 OR EQUIVALENT.
LCLC
LC
LC
THERMOSTAT LIGHT SWITCH ELECTRICAL OUTLET DATA OUTLET
COUNTER/ BENCH/ CASEWORK - AT GALLEY/ LAVATORY/ WORK FILE RM
TELEPHONE OUTLET
DATA OUTLET
ELECTRICAL OUTLET
RACEWAY (@ TOP OF
BACKSPLASH, TYP.)
U O
N
1'
U O
N
1'
"3'
2'
0" A
D A
3'
3'
AT LOCATIONS
NOT ADJACENT
TO LIGHT SWITCH
M A
X
1' - 0"
THERMOSTAT
(IF REQ.)
1ST
LIGHT SWITCH
SWITCHING LAYOUT
DOOR OR SWING
SECONDARY
CONTROL
(IF REQ.)
2ND & 3RD
LIGHT SWITCHS
(IF REQ.)
6" 6"
6" 3'
M A
X F
O R
O P
E R
A B
LE
P
A R
T S
4'
S E
E D
O O
R S
C H
E D
U
LE
LC
LC
LC
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
G100
GENERAL NOTES / SYMBOLS /
ABBREVIATIONS
BS/TS Checker
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
ARCHITECTURAL
LS031 JCK 31ST FLOOR - LIFE SAFETY SHEET
LS033 JCK 33RD FLOOR - LIFE SAFETY SHEET
D131 JCK 31ST FLOOR - DEMOLITION PLAN
D133 JCK 33RD FLOOR - DEMOLITION PLAN
D231 JCK 31ST FLOOR - DEMOLITION REFLECTED CEILING PLAN
D233 JCK 33RD FLOOR - DEMOLITION REFLECTED CEILING PLAN
A131 JCK 31ST FLOOR - FLOOR PLAN
A131.1 JCK 31ST FLOOR - DIMENSION PLAN
AF131 JCK 31ST FLOOR - FURNITURE PLAN (NIC)
A133 JCK 33RD FLOOR - FLOOR PLAN
A133.1 JCK 33RD FLOOR - DIMENSION PLAN
AF133 JCK 33RD FLOOR - FURNITURE PLAN (NIC)
A231 JCK 31ST FLOOR - REFLECTED CEILING PLAN
A233 JCK 33RD FLOOR - REFLECTED CEILING PLAN
A400 JCK - INTERIOR ELEVATIONS
A401 JCK - FOLDING PARTITION ENLARGED PLAN AND DETAILS
A402 JCK - FOLDING PARTITION ENLARGED PLAN AND DETAILS
A500 JCK - STANDARD PARTITION TYPES AND DETAILS
A600 JCK - ROOM FINISH SCHEDULE - LEVEL 31
A601 JCK - ROOM FINISH SCHEDULE - LEVEL 33
A602 JCK - DOOR SCHEDULE - LEVEL 31
A603 JCK - DOOR SCHEDULE - LEVEL 33
A604 JCK - SIGNAGE SCHEDULE
A605 JCK - WORKSTATION SIGNAGE SCHEDULE
A606 JCK - 31ST FLOOR SIGNAGE PLAN
A607 JCK - 33RD FLOOR SIGNAGE PLAN
GENERAL
G000 JCK COVER
G100 GENERAL NOTES / SYMBOLS / ABBREVIATIONS
MECHANICAL
M-000 JCK MECHANICAL ABBREVIATIONS, SYMBOLS, GENERAL NOTES AND
DRAWING LIST
M-131 JCK LEVEL 31 - MECHANICAL DEMOLITION PLAN
M-133 JCK LEVEL 33 - MECHANICAL DEMOLITION PLAN
M-331 JCK LEVEL 31 - MECHANICAL DUCTWORK PLAN
M-333 JCK LEVEL 33 - MECHANICAL DUCTWORK PLAN
M-431 JCK LEVEL 31 - MECHANICAL PIPING PLAN
M-433 JCK LEVEL 33 - MECHANICAL PIPING PLAN
M-531 JCK LEVEL 31 - MECHANICAL CONTROLS PLAN
M-533 JCK LEVEL 33 - MECHANICAL CONTROLS PLAN
M-600 JCK MECHANICAL SCHEDULES
M-800 JCK MECHANICAL DETAILS
M-801 JCK MECHANICAL DETAILS
M-802 JCK MECHANICAL DETAILS
ELECTRICAL
E-000 JCK ELECTRICAL ABBREVIATIONS, SYMBOLS, GENERAL NOTES AND
DRAWING LIST
E-131 JCK LEVEL 31 - ELECTRICAL DEMOLITION PLAN
E-131.1 JCK LEVEL 31 - ELECTRICAL LIGHTING DEMOLITION PLAN
E-133 JCK LEVEL 33 - ELECTRICAL DEMOLITION PLAN
E-133.1 JCK LEVEL 33 - ELECTRICAL LIGHTING DEMOLITION PLAN
E-231 JCK LEVEL 31 - ELECTRICAL LIGHTING PLAN
E-233 JCK LEVEL 33 - ELECTRICAL LIGHTING PLAN
E-331 JCK LEVEL 31 - ELECTRICAL POWER PLAN
E-333 JCK LEVEL 33 - ELECTRICAL POWER PLAN
E-333.1 JCK LEVEL 33 - ELECTRICAL IN FLOOR SYSTEM
E-431 JCK LEVEL 31 - TELECOM & SECURITY PLAN
E-433 JCK LEVEL 33 - TELECOM & SECURITY PLAN
E-500 JCK ELECTRICAL ENLARGED PLANS
E-700 JCK ELECTRICAL RISER DIAGRAM
E-800 JCK ELECTRICAL DETAILS
E-801 JCK LOW VOLTAGE DETAILS
E-802 JCK LOW VOLTAGE DETAILS
E-803 JCK LOW VOLTAGE DETAILS
E-900 JCK LIGHTING FIXTURE SCHEDULE AND CONTROLS NARRATIVE
E-901 JCK ENLIGHTING LIGHTING CONTROLS NARRATIVE
E-902 JCK ELECTRICAL PANEL SCHEDULES
PLUMBING
P-000 JCK PLUMBING ABBREVIATIONS, SCHEDULES, SYMBOLS, GENERAL
NOTES AND DRAWING LIST
P-131 JCK LEVEL 31 - PLUMBING DEMOLITION PLAN
P-133 JCK LEVEL 33 - PLUMBING DEMOLITION PLAN
P-230 JCK LEVEL 30 - PLUMBING PLAN
P-231 JCK LEVEL 31 - PLUMBING PLAN
P-232 JCK LEVEL 32 - PLUMBING PLAN
P-233 JCK LEVEL 33 - PLUMBING PLAN
P-400 JCK PLUMBING ENLARGED PLANS AND SECTIONS
P-500 JCK PLUMBING RISER DIAGRAMS
P-800 JCK PLUMBING DETAILS
FIRE PROTECTION
FP-000 JCK FIRE PROTECTION ABBREVIATIONS, SYMBOLS, GENERAL NOTES
AND DRAWING LIST
FP-131 JCK LEVEL 31 - FIRE PROTECTION DEMOLITION PLAN
FP-133 JCK LEVEL 33 - FIRE PROTECTION DEMOLITION PLAN
FP-231 JCK LEVEL 31 - FIRE PROTECTION PLAN
FP-233 JCK LEVEL 33 - FIRE PROTECTION PLAN
FP-800 JCK FIRE PROTECTION DETAILS
DRAWING LIST
FIRE ALARM
FA-000 JCK FIRE ALARM ABBREVIATIONS, SYMBOLS, GENERAL NOTES AND
DRAWING LIST
FA-131 JCK LEVEL 31 - FIRE ALARM DEMOLITION PLAN
FA-133 JCK LEVEL 33 - FIRE ALARM DEMOLITION PLAN
FA-231 JCK LEVEL 31 - FIRE ALARM PLAN
FA-233 JCK LEVEL 33 - FIRE ALARM PLAN
FA-800 JCK FIRE ALARM DETAILS
ACOUSTICS
AC-000 JCK SOUND MASKING ABBREVIATIONS, SYMBOLS, GENERAL NOTES
AND DRAWING LIST
AC-231 JCK LEVEL 31 - SOUND MASKING PLAN
AC-233 JCK LEVEL 33 - SOUND MASKING PLAN
AC-601 JCK SOUND MASKING DETAILS
ACM-131 JCK LEVEL 31 - ASBESTOS ABATEMENT
ACM-133 JCK LEVEL 33 - ASBESTOS ABATEMENT
AUDIOVISUAL
AV-000 JCK AUDIO VISUAL ABBREVIATIONS, SYMBOLS, GENERAL NOTES AND
DRAWING LIST
AV-001 JCK AUDIOVISUAL SCHEDULES
AV-131 JCK LEVEL 31 - AUDIOVISUAL DEMOLITION PLAN
AV-133 JCK LEVEL 33 - AUDIOVISUAL DEMOLITION PLAN
AV-331 JCK LEVEL 31 - AUDIOVISUAL OVERALL PLAN
AV-333 JCK LEVEL 33 - AUDIOVISUAL OVERALL PLAN
AV-431 JCK LEVEL 31 - AUDIOVISUAL EQUIPMENT PLAN
AV-432 JCK LEVEL 31 - AUDIOVISUAL INFRASTRUCTURE PLAN
AV-434 JCK LEVEL 33 - AUDIOVISUAL EQUIPMENT PLAN
AV-435 JCK LEVEL 33 - AUDIOVISUAL INFRASTRUCTURE PLAN
AV-436 JCK LEVEL 33 - AUDIOVISUAL EQUIPMENT RCP
AV-437 JCK LEVEL 33 - AUDIOVISUAL INFRASTRUCTURE RCP
AV-600 JCK AUDIOVISUAL ELEVATIONS, RISER DIAGRAMS
AV-601 JCK AUDIOVISUAL ELEVATIONS, RISER DIAGRAMS
AV-700 JCK AUDIOVISUAL FUNCTIONAL DIAGRAMS
AV-701 JCK AUDIOVISUAL FUNCTIONAL DIAGRAMS
AV-702 JCK AUDIOVISUAL FUNCTIONAL DIAGRAMS
AV-703 JCK AUDIOVISUAL FUNCTIONAL DIAGRAMS
ASBESTOS CONTAINING MATERIAL
ACM-131 JCK LEVEL 31 - ASBESTOS ABATEMENT
ACM-133 JCK LEVEL 33 - ASBESTOS ABATEMENT
ABCDEFGHJ
69 SF
OGC PANTRY
105 SF
OGC COPY/MAILING ROOM
106 SF
PRINT/COPY/LIBRARY AREA
6 SF
COATS
60 SF
IDF
126 SF
OGC OFFICE
118 SF
OGC OFFICE
117 SF
OGC OFFICE
117 SF
OGC OFFICE
118 SF
OGC OFFICE
117 SF
OGC OFFICE
117 SF
OGC OFFICE
118 SF
OGC OFFICE
117 SF
OGC OFFICE
117 SF
OGC OFFICE
118 SF
OGC OFFICE
117 SF
OGC OFFICE
117 SF
OGC OFFICE
118 SF
OGC OFFICE
117 SF
OGC OFFICE
117 SF
OGC OFFICE
118 SF
OGC OFFICE
117 SF
OGC OFFICE
117 SF
OGC OFFICE
118 SF
OGC OFFICE
117 SF
OGC OFFICE
117 SF
OGC OFFICE
118 SF
OGC OFFICE
126 SF
DEPUTY CHIEF COUNSEL OFFICE
116 SF
OGC OFFICE
114 SF
OGC OFFICE
113 SF
OGC OFFICE
113 SF
OGC OFFICE
113 SF
OGC OFFICE
114 SF
OGC OFFICE
117 SF
OGC OFFICE
109 SF
OGC OFFICE
117 SF
OGC OFFICE
117 SF
OGC OFFICE
107 SF
OGC OFFICE
117 SF
OGC OFFICE 121 SF
OGC HUDDLE
131 SF
CHIEF COUNSEL OFFICE
T R
A V
E L
D
IS
T A
N C
E : 1
0"
DEAD END DISTANCE: 34' - 9"
TRAVEL DISTANCE: 147' - 0" TRAVEL DISTANCE: 120' - 0"
106 SF
OGC OFFICE
285 SF
RECEPTION
1065 SF
CORRIDOR
41 SF
CORRIDOR
K
AREAS OUT OF GENERAL
ARCHITECTURAL SCOPE.
TRAVEL DISTANCE
2 HOUR CONSTRUCTION (EXISTING)
SURFACE MOUNTED FIRE EXTINGUISHER LOCATION -
LOCATIONS TO BE COORDINATED WITH AHJ
FEC
OCCUPANCY KEY
OFFICE
CIRCULATION
STORAGE/MECHANICAL
DEAD END DISTANCE
PUBLIC CORRIDOR - THIS
AREA IS OUT OF GENERAL
ARCHITECTURAL SCOPE.
OFFICE - COLLABORATION
SPACES <450 SF
ASSEMBLY
SAFETY AND OCCUPANCY PLAN
CONSTRUCTION TYPE 1-A / EXISTING
FULLY SPRINKLED BUILDING
OCCUPANCY CLASS BUSINESS B
MAX TRAVEL DISTANCE 300'-0"
MAX DEAD END CORRIDOR 50'-0"
EXISTING EGRESS STAIRWAY CAPACITY
31ST FLOOR EGRESS STAIR - NFPA 101 - 7.3.3.1
WIDTH (in) FACTOR
OCCUPANT
CAPACITY
O C
C U
P A
N C
Y C
L A
S S
B
(B
U S
IN
E
S S
EAST STAIR
WEST STAIR
SUBTOTAL
.3
.3
EXIT 1
EXIT 2
TOTAL EXIT CAPACITY 292
31ST FLOOR OCCUPANCY
BASED ON NFPA 101 SF/OCCUPANT - TABLE 7.3.1.2
KEY
1/150
1/500
CIRCULATION
OFFICE
STORAGE/MECHANICAL
TOTAL EXIT CAPACITY 292 > 39 OK
LEVEL 31 OCCUPANCY
1/30121OFFICE - COLLABORATION
SPACES <450 SF
1/150 0ASSEMBLY -
CONFERENCE ROOM USE
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
LS031
JCK 31ST FLOOR - LIFE SAFETY SHEET
BS/TS Checker
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
1/8" = 1'-0"
LEVEL 31 - LIFE SAFETY PLAN
0' 4' 8' 16' 32'
NOTE TO AHJ: ARE FIRE EXTINGUISHERS DESIRED FOR THIS PROJECT?
D N U P
U
PD
N
ABCDEFGHJ
RECEPTION
90 SF
MDF / LAN
531 SF
EVIDENCE
400 SF
HEARING ROOM
262 SF
PRETRIAL ROOM
237 SF
SEQUESTER ROOM
181 SF
OCR MEETING ROOM
121 SF
OCR OFFICE
122 SF
OCR OFFICE
122 SF
OCR OFFICE
124 SF
OCR OFFICE
123 SF
OCR OFFICE
122 SF
OCR OFFICE
122 SF
OCR OFFICE
123 SF
OCR OFFICE
122 SF
CMS UNION OFFICE
120 SF
OGC OFFICE / HUDDLE
119 SF
OGC OFFICE / HUDDLE
130 SF
CMS HUDDLE
126 SF
COPY
97 SF
118 SF
HSPD - 12
156 SF
SUPPLIES STORAGE
70 SF
OUTREACH STORAGE
122 SF
CMS OFFICE
123 SF
CMS OFFICE
122 SF
CMS OFFICE
344 SF
CONFERENCE ROOM
124 SF
CMS OFFICE
125 SF
CMS OFFICE
124 SF
CMS OFFICE
251 SF
EXECUTIVE CONF. ROOM
124 SF
CMS RA OFFICE
116 SF
CMS OFFICE
110 SF
CMS HUDDLE
116 SF
CMS OFFICE
108 SF
CMS HUDDLE
122 SF
CMS OFFICE
123 SF
CMS OFFICE
124 SF
CMS OFFICE
370 SF
COLLABORATION AREA
280 SF
BREAK
122 SF
PANTRY
159 SF
SUPPLIES / LOCKER STORAGE137 SF
CMS HUDDLE
122 SF
CMS OFFICE
122 SF
CMS OFFICE
123 SF
CMS OFFICE
56 SF
CMS FOCUS
62 SF
CMS FOCUS
1024 SF
MULTIPURPOSE ROOM
200 SF
SERVER
448 SF
IT STORAGE / WORKSHOP
DEAD END DISTANCE: 30' - 5" DEAD END
DISTANCE: 14' - 1"
DEAD END
DISTANCE: 14' - 1"
DEAD END DISTANCE: 41' - 7"
TRAVEL DISTANCE: 162' - 0"
TRAVEL DISTANCE: 171' - 0"
111 SF
CONF. FURNITURE STORAGE
TRAVEL DISTANCE: 153' - 0"
44 SF
CMS FOCUS
44 SF
CMS FOCUS
121 SF
OGC OFFICE / HUDDLE
K
24 SF
AV CLOSET
SAFETY AND OCCUPANCY PLAN
CONSTRUCTION TYPE 1-A / EXISTING
FULLY SPRINKLED BUILDING
OCCUPANCY CLASS ASSEMBLY A AND BUSINESS B
MAX TRAVEL DISTANCE 300'-0"
MAX DEAD END CORRIDOR 50'-0"
33RD FLOOR OCCUPANCY
BASED ON NFPA 101 SF/OCCUPANT - TABLE 7.3.1.2
KEY
1/150
1/500
10235
CIRCULATION
OFFICE
STORAGE/MECHANICAL
TOTAL EXIT CAPACITY 292 > 286 OK
LEVEL 33 OCCUPANCY
1/301629OFFICE - COLLABORATION
SPACES <450 SF
1/152364 158ASSEMBLY -
CONFERENCE ROOM USE
EXISTING EGRESS STAIRWAY CAPACITY
33RD FLOOR EGRESS STAIR - NFPA 101 - 7.3.3.1
WIDTH (in) FACTOR
OCCUPANT
CAPACITY
O C
C U
P A
N C
Y C
L A
S S
A
B
(A
S S
E M
B L
Y
B U
S
IN
E S
S
EAST STAIR
WEST STAIR
.3
.3
EXIT 1
EXIT 2
TOTAL EXIT CAPACITY 292
AREAS OUT OF GENERAL
ARCHITECTURAL SCOPE.
TRAVEL DISTANCE
2 HOUR CONSTRUCTION (EXISTING)
SURFACE MOUNTED FIRE EXTINGUISHER LOCATION -
LOCATIONS TO BE COORDINATED WITH AHJ
FEC
OCCUPANCY KEY
OFFICE
CIRCULATION
STORAGE/MECHANICAL
DEAD END DISTANCE
PUBLIC CORRIDOR - THIS
AREA IS OUT OF GENERAL
ARCHITECTURAL SCOPE.
OFFICE - COLLABORATION
SPACES <450 SF
ASSEMBLY
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
LS033
JCK 33RD FLOOR - LIFE SAFETY SHEET
BS/TS Checker
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
1/8" = 1'-0"
LEVEL 33 - LIFE SAFETY PLAN
P
U
PD
N
ABCDEFGHJ
5 4
28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"
K
GENERAL NOTES
1. PROTECT EXTERIOR WINDOW TREATMENTS FROM DUST AND DEBRIS DURING
DEMOLITION AND CONSTRUCTION.
2. PROTECT ALL PERIMETER FLOOR MOUNTED FAN-COIL UNITS FROM DUST AND
DEBRIS DURING DEMOLITION, AND CONSTRUCTION.
3. PROTECT ARCHITECTURAL COLUMN CLADDING ON ALL EXTERIOR PERIMETER
COLUMNS FROM DUST, DEBRIS, AND DAMAGE DURING DEMOLITION, AND
CONSTRUCTION.
4. REFER TO THE MEP DISCIPLINE DRAWINGS FOR EXTENT OF MEP SYSTEM DEMOLITION.
5. PROTECT EXISTING WALLS AND FINISHES IN THE ADJACENT NO WORK AREA THAT
INTERFACE WITH THE AREA OF WORK.
6. ASBESTOS CONTAINING MATERIAL:
ASBESTOS WAS CONFIRMED PRESENT IN THE MASTIC BENEATH THE CARPET IN THE
WEST OFFICE AREA (APPROXIMATELY 1300 SF) - SEE HATCHED AREA ON ABOVE PLAN.
REFER TO ABATEMENT DRAWINGS AND PRE-ALTERATION SURVEY IN THE APPENDIX OF
THE PROJECT SPECIFICATIONS
7. ALL EXISTING FURNITURE REMAINING IN THE SUITE AT START OF CONSTRUCTION IS TO
BE REMOVED AND RECYCLED WHERE POSSIBLE OR ELSE DISPOSED OF
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE REMOVED
DEMOLITION KEY NOTE - SEE
KEYNOTE LEGEND
LEGEND
DEMOLITION PHOTO KEY
NOTE - SEE KEYNOTE LEGEND
AREAS OUT OF GENERAL
ARCHITECTURAL SCOPE.
PUBLIC CORRIDOR - EXISTING
TO REMAIN - ANTICIPATED
WORK LIMITED TO PATCH/
REPAIR AS NECESSITATED BY
REMOVAL AND REPLACEMENT
OF SUITE PERIMETER WALL
AND UTILITY CONNECTIONS
ASSOCIATED WITH MEP SCOPE
OF WORK
31ST FLOOR DEMOLITION PHOTOS
2 3
EXISTING
CASEWORK
EXISTING COLUMN
EXISTING
STOREFRONT
EXISTING
CASEWORK
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
D131
JCK 31ST FLOOR - DEMOLITION PLAN
BS/TS LW/CY
1/8" = 1'-0"
LEVEL 31 - DEMO PLAN
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
0' 4' 8' 16' 32'
31ST FLOOR DEMO PLAN KEYNOTE LEGEND
KEYNOTE
NUMBER TEXT
1 EXISTING COLUMN ENCLOSURES TO REMAIN - PATCH TO MATCH ADJACENT FINISH AS EQUIRED WHERE ADJACENT CONDITIONS
ARE REMOVED - REMOVE EXISTING BASE - TYPICAL THROUGOUT
2 REMOVE EXISTING RESILIENT BASE, CARPET, UNDERLAYMENT, AND ADHESIVE DOWN TO SLAB IN PREPARATION FOR NEW FLOOR FINISH - TYPICAL THROUGHOUT ENTIRE SUITE AND BETWEEN FAN COIL UNIT AND CURTAIN WALL
3 REMOVE EXISTING CORRIDOR WALL SYSTEM AND BASE
4 REMOVE EXISTING DOORS, FRAMES AND HARDWARE (INCLUDING SIDELITES WHERE APPLICABLE) THROUGHOUT ENTIRE SUITE
EXCEPT WHERE SPECIFICALLY NOTED TO REMAIN
5 REMOVE EXISTING GYP BOARD PARTITIONS FOR ENTIRE HEIGHT - TYPICAL THROUGHOUT ENTIRE SUITE - AS INDICATED BY
DASHED LINES (REFER TO LEGEND)
6 EXISTING GLAZED STOREFRONT SYSTEM AND ASSOCIATED HARDWARE TO BE REMOVED
7 REMOVE EXISTING CASEWORK AND PLUMBING FIXTURES WHERE APPLICABLE - REFER TO MEP DEMOLTION DRAWINGS FOR
FURTHER INFORMATION
9 REMOVE EXISTING SERVICE WINDOW AND COUNTERTOP AT HIGH DENSITY FILE STORAGE SYSTEM (REFER TO PHOTO #1)
10 DEMOLISH EXISTING PANTRY WITH CASEWORK. SEE MEP FOR PLUMBING DEMOLITION SCOPE (SEE PHOTO #1)
11 DEMOLISH EXISTING CASEWORK. SEE MEP FOR PLUMBING DEMOLITION SCOPE (SEE PHOTO #2)
12 PROTECT EXISTING COLUMNS AND ARCHITECTURAL CLADDING FROM DUST AND DEBRIS DURING DEMOLITION, AND CONSTRUCTION. DEMOLISH AND REPLACE EXISTING VINYL BASE AT ALL COLUMNS. REPAIR, REPAINT, AND REFINISH COLUMN
CLADDING DAMAGED BY DEMOLITION AND CONSTRUCTION, TYP. (SEE PHOTO #3)
13 EXISTING CORRIDOR CARPET TO REMAIN - COVER AND PROTECT AS REQURIED DURING ADJACENT DEMOLITON - DAMAGED
CARPET TILES TO BE REPLACED IN KIND
ASBESTOS CONFIRMED
PRESENT IN THE BLACK
MASTIC BENEATH EXISTING
CARPET SEE ENVIRONMENTAL
DRAWINGS
P
U
PD
N
ABCDEFGHJ
3 3
28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"
6 6 6
5 5
K
12 12
CONFIRMATION OF EXISTING WALL
CONSTRUCTION REQUIRED -
SOME MODIFICATION MAY BE
REQUIRED TO ACCOMMODATE
LATERAL ROUTING OF NEW
INSULATED PLUMBING PIPING
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE REMOVED
DEMOLITION KEY NOTE - SEE
KEYNOTE LEGEND
LEGEND
DEMOLITION PHOTO KEY
NOTE - SEE KEYNOTE LEGEND
AREAS OUT OF GENERAL
ARCHITECTURAL SCOPE.
PUBLIC CORRIDOR - EXISTING
TO REMAIN - ANTICIPATED
WORK LIMITED TO PATCH/
REPAIR AS NECESSITATED BY
REMOVAL AND REPLACEMENT
OF SUITE PERIMETER WALL
AND UTILITY CONNECTIONS
ASSOCIATED WITH MEP SCOPE
OF WORK
GENERAL NOTES
1. PROTECT EXTERIOR WINDOW TREATMENTS FROM DUST AND DEBRIS DURING
DEMOLITION AND CONSTRUCTION.
2. PROTECT ALL PERIMETER FLOOR MOUNTED FAN-COIL UNITS FROM DUST AND
DEBRIS DURING DEMOLITION, AND CONSTRUCTION.
3. PROTECT ARCHITECTURAL COLUMN CLADDING ON ALL EXTERIOR PERIMETER
COLUMNS FROM DUST, DEBRIS, AND DAMAGE DURING DEMOLITION, AND
CONSTRUCTION.
4. REFER TO THE MEP DISCIPLINE DRAWINGS FOR EXTENT OF MEP SYSTEM DEMOLITION.
5. PROTECT EXISTING WALLS AND FINISHES IN THE ADJACENT NO WORK AREA THAT
INTERFACE WITH THE AREA OF WORK.
6. ASBESTOS CONTAINING MATERIAL:
ASBESTOS WAS CONFIRMED PRESENT IN THE MASTIC BENEATH THE CARPET IN THE
WEST OFFICE AREA (APPROXIMATELY 1300 SF) - SEE HATCHED AREA ON ABOVE PLAN.
REFER TO ABATEMENT DRAWINGS AND PRE-ALTERATION SURVEY IN THE APPENDIX OF
THE PROJECT SPECIFICATIONS
7. ALL EXISTING FURNITURE REMAINING IN THE SUITE AT START OF CONSTRUCTION IS TO
BE REMOVED AND RECYCLED WHERE POSSIBLE OR ELSE DISPOSED OF
33RD FLOOR DEMOLITION PHOTOS
2 3
EXISTING SERVICE
WINDOW TO BE REMOVED
EXISTING COLUMN
EXISTING PANTRY
EXISTING ROOM
DIVIDER
6 87
EXISTING ICE MAKER -
SALVAGE FOR
REINSTALLATION
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
D133
JCK 33RD FLOOR - DEMOLITION PLAN
BS/TS LW/CY
1/8" = 1'-0"
LEVEL 33 - DEMOLITION PLAN
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
33RD FLOOR DEMO PLAN KEYNOTE LEGEND
KEY NOTE
NUMBER TEXT
1 EXISTING COLUMN ENCLOSURES TO REMAIN - PATCH TO MATCH ADJACENT FINISH AS EQUIRED WHERE ADJACENT CONDITIONS
ARE REMOVED - REMOVE EXISTING BASE - TYPICAL THROUGOUT
2 REMOVE EXISTING RESILIENT BASE, CARPET, UNDERLAYMENT, AND ADHESIVE DOWN TO SLAB IN PREPARATION FOR NEW FLOOR FINISH - TYPICAL THROUGHOUT ENTIRE SUITE AND BETWEEN FAN COIL UNIT AND CURTAIN WALL
3 REMOVE EXISTING CORRIDOR WALL SYSTEM AND BASE
4 REMOVE EXISTING DOORS, FRAMES AND HARDWARE (INCLUDING SIDELITES WHERE APPLICABLE) THROUGHOUT ENTIRE SUITE
EXCEPT WHERE SPECIFICALLY NOTED TO REMAIN
5 REMOVE EXISTING GYP BOARD PARTITIONS FOR ENTIRE HEIGHT - TYPICAL THROUGHOUT ENTIRE SUITE - AS INDICATED BY
DASHED LINES (REFER TO LEGEND)
6 REMOVE DEMOUNTABLE PARTITION SYSTEM, INCLUDING DOORS, ASSOCIATED HARDWARE, AND SIDELITES
7 REMOVE EXISTING SERVICE WINDOW AND COUNTERTOP AT HIGH DENSITY FILE STORAGE SYSTEM (REFER TO PHOTO #1)
8 REMOVE EXISTING HIGH DENSITY FILE (HDF) STORAGE SYSTEM. ALONG WITH HDF TRACKS AND RAISED FLOOR ASSEMBLY (REFER TO PHOTO #2) PATCH REPAIR FLOOR SLAB AS REQUIRED IN PREPARATION FOR NEW FLOOR FINISH
9 PROTECT EXISTING COLUMNS AND ARCHITECTURAL CLADDING FROM DUST AND DEBRIS DURING DEMOLITION, AND CONSTRUCTION. DEMOLISH AND REPLACE EXISTING VINYL BASE AT ALL COLUMNS. REPAIR, REPAINT, AND REFINISH COLUMN
CLADDING DAMAGED BY DEMOLITION AND CONSTRUCTION, TYP. (REFER TO PHOTO #3)
10 EXISTING PANTRY CASEWORK, REFRIGERATOR, AND PLUMBING FIXTURES TO BE REMOVED (REFER TO PLUMBING DRAWINGS) - NOTE, EXISTING ICE MACHINE TO BE SALVAGED FOR RE-INSTALLATION - SEE PHOTOS 4 AND 6
11 PROTECT EXISTING ROOM DIVIDER AT EXISTING PANTRY. EXISTING ROOM DIVIDER TO REMAIN AND BE REUSED (SEE PHOTO #5)
12 REMOVE AND SALVAGE EXISTING LOCKERS - TURN OVER TO GSA PROPERTY MANAGEMENT - (REFER TO PHOTO #8)
13 REMOVE EXISTING WALL MOUNTED CASEWORK
(SEE PHOTO #7)
P
U
PD
N
FACP
FACP
ABCDEFGHJ
28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"
A401
K
CORRIDOR CEILING:
DESIGN INTENT IS TO RETAIN EXISTING CORRIDOR
CEILING AND LIGHTING (LIGHT GRAY AREA) - SOME
REPAIR/REPLACEMENT MAY BE NECESSITATED BY
ADJACENT DEMOLITION SCOPE. CONTRACTOR IS
RESPONSIBLE FOR REPAIRING AND REPLACING
THE CEILING IN KIND AS REQUIRED.
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE REMOVED
LEGEND
EXISTING LIGHTING TO BE
REMOVED AND DISCARDED
EXISTING ACT CEILING TO BE
REMOVED AND DISCARDED
EXISTING AIR TERMINAL TO BE
REMOVED AND DISCARDED
EXISTING ACCESS HATCH TO
BE REMOVED AND DISCARDED
AREAS OUT OF GENERAL
ARCHITECTURAL SCOPE.
PUBLIC CORRIDOR - EXISTING
TO REMAIN - NO WORK
ANTICIPATED EXCEPT UTILITY
CONNECTIONS AS
REFERENCED ON MEP
DRAWINGS - REPAIR / REPLACE
AS REQUIRED
GENERAL NOTES
1. PROTECT EXTERIOR WINDOW TREATMENTS/ BLINDS TO REMAIN FROM DUST AND DEBRIS
DURING DEMOLITION AND CONSTRUCTION.
2. PROTECT ALL PERIMETER FLOOR MOUNTED FAN-COIL UNITS FROM DUST AND DEBRIS
DURING DEMOLITION, AND CONSTRUCTION.
3. PROTECT ARCHITECTURAL COLUMN CLADDING ON ALL COLUMNS FROM DUST, DEBRIS, AND
DAMAGE DURING DEMOLITION, AND CONSTRUCTION.
4. REFER TO THE MEP DISCIPLINE DRAWINGS FOR THE EXTENT OF THE MEP SYSTEM
DEMOLITION. NOTE THAT SOME M/E/FP SYSTEMS SHALL BE MAINTAINED TO KEEP THE SPACE
CODE-COMPLIANT.
5. REMOVE AND DISCARD ALL AIR TERMINALS FROM CEILING.
6. ASBESTOS CONTAINING MATERIAL:
ASBESTOS WAS CONFIRMED PRESENT IN EXISTING DUCT SEALANT (DARK GRAY SEAM
SEALANT) AT 31ST, 32ND AND 33RD FLOOR SPACES - REFER TO PRE-ALTERATION SURVEY
INCLUDED IN THE APPENDIX OF THE PROJECT SPECIFICATIONS. (NOTE THAT MATERIAL MAY
BE PRESENT IN AREAS NOT IDENTIFIED IN THE SURVEY AREA.
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
D231
JCK 31ST FLOOR - DEMOLITION REFLECTED
CEILING PLAN
BS/TS LW/CY
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
1/8" = 1'-0"
LEVEL 31 - DEMOLITION REFLECTED
CEILING PLAN
P
U
PD
N
ABCDEFGHJ
28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"
EXISTING LIGHTING TO BE
REMOVED AND SALVAGED
FOR REINSTALLATION -
REFER TO ELECTRICAL
DRAWINGS
EXISTING PAINTED BREAK
METAL CLOSURE TRIM TO
REMAIN - TYP. ALONG
EXTERIOR WALL
K
CORRIDOR CEILING:
DESIGN INTENT IS TO RETAIN EXISTING CORRIDOR
CEILING AND LIGHTING (LIGHT GRAY AREA) - SOME
REPAIR/REPLACEMENT MAY BE NECESSITATED BY
ADJACENT DEMOLITION SCOPE. CONTRACTOR IS
RESPONSIBLE FOR REPAIRING AND REPLACING
THE CEILING IN KIND AS REQUIRED.
EXISTING PANTRY CEILING TO REMAIN
GENERAL NOTES
1. PROTECT EXTERIOR WINDOW TREATMENTS/ BLINDS TO REMAIN FROM DUST AND DEBRIS
DURING DEMOLITION AND CONSTRUCTION.
2. PROTECT ALL PERIMETER FLOOR MOUNTED FAN-COIL UNITS FROM DUST AND DEBRIS
DURING DEMOLITION, AND CONSTRUCTION.
3. PROTECT ARCHITECTURAL COLUMN CLADDING ON ALL COLUMNS FROM DUST, DEBRIS, AND
DAMAGE DURING DEMOLITION, AND CONSTRUCTION.
4. REFER TO THE MEP DISCIPLINE DRAWINGS FOR THE EXTENT OF THE MEP SYSTEM
DEMOLITION. NOTE THAT SOME M/E/FP SYSTEMS SHALL BE MAINTAINED TO KEEP THE SPACE
CODE-COMPLIANT.
5. REMOVE AND DISCARD ALL AIR TERMINALS FROM CEILING.
6. ASBESTOS CONTAINING MATERIAL:
ASBESTOS WAS CONFIRMED PRESENT IN EXISTING DUCT SEALANT (DARK GRAY SEAM
SEALANT) AT 31ST, 32ND AND 33RD FLOOR SPACES - REFER TO PRE-ALTERATION SURVEY
INCLUDED IN THE APPENDIX OF THE PROJECT SPECIFICATIONS. (NOTE THAT MATERIAL MAY
BE PRESENT IN AREAS NOT IDENTIFIED IN THE SURVEY AREA.
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE REMOVED
LEGEND
EXISTING LIGHTING TO BE
REMOVED AND DISCARDED
EXISTING ACT CEILING TO BE
REMOVED AND DISCARDED
EXISTING AIR TERMINAL TO BE
REMOVED AND DISCARDED
EXISTING ACCESS HATCH TO
BE REMOVED AND DISCARDED
AREAS OUT OF GENERAL
ARCHITECTURAL SCOPE.
PUBLIC CORRIDOR - EXISTING
TO REMAIN - NO WORK
ANTICIPATED EXCEPT UTILITY
CONNECTIONS AS
REFERENCED ON MEP
DRAWINGS - REPAIR / REPLACE
AS REQUIRED
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
D233
JCK 33RD FLOOR - DEMOLITION REFLECTED
CEILING PLAN
BS/TS LW/CY
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
1/8" = 1'-0"
LEVEL 33 - DEMOLITION REFLECTED
CEILING PLAN
OGC PANTRY
31038
PRINT/COPY/LIBRARY AREA
31070
COATS
31128
IDF
31034
OGC OFFICE
31042
OGC OFFICE
31046
OGC OFFICE
31050
OGC OFFICE
31052
OGC OFFICE
31054
OGC OFFICE
31058
OGC OFFICE
31062
OGC OFFICE
31066
OGC OFFICE
31068
OGC OFFICE
31072
OGC OFFICE
31074
OGC OFFICE
31076
OGC OFFICE
31078
OGC OFFICE
31082
OGC OFFICE
31086
OGC OFFICE
31092
OGC OFFICE
31096
OGC OFFICE
31100
OGC OFFICE
31104
OGC OFFICE
31106
OGC OFFICE
31108
OGC OFFICE
31112
OGC OFFICE
31114
DEPUTY CHIEF
COUNSEL OFFICE
31118
OGC OFFICE
31040
OGC OFFICE
31044
OGC OFFICE
31048
OGC OFFICE
31056
OGC OFFICE
31060
OGC OFFICE
31064
OGC OFFICE
31080
OGC OFFICE
31084
OGC OFFICE
31090
OGC OFFICE
31094
OGC OFFICE
31098
OGC OFFICE
31102
OGC HUDDLE
31116
CHIEF COUNSEL
OFFICE
31120
28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"
31038
31048
31036
A4001
A400
31034
A131.1
Sim
31120
310A
A4002
31042 31046 31050 31052 31054 31058 31062 31066
31064310603105631044
31068 31072 31114 31118
311123110831106
3110231098
3110431100
31094
31092 31096
31080
3108631082310783107631074
CORRIDOR
31126
31122
OGC COPY/MAILING
ROOM
31036
CENTER PARTITION ON MULLION OR
COLUMN (TYP.)
UNLESS NOTED OTHERWISE
-SEE DETAIL 1/A-500
OGC OFFICE
31110
RECEPTION
31122
CORRIDOR
31124
31116
311103109031084
A401
31126
31040
FOLDING PANEL PARTITION B
A401
K
WALL MTD. MONITOR -
REFER TO AV DRAWINGS
GENERAL NOTES
1. REFER TO SHEET A131.1 FOR WALL LAYOUT AND WALL TYPE INFORMATION
2. PROVIDE BLOCKING IN WALLS AT WALL MOUNTED EQUIPMENT LOCATIONS -
REFER TO MEP DRAWINGS.
3. ALL COAT CLOSETS TO RECEIVE HANGING ROD AND SHELF.
4. PROTECT EXTERIOR WINDOW TREATMENTS/ BLINDS TO REMAIN FREE FROM
DUST AND DEBRIS DURING DEMOLITION AND CONSTRUCTION.
5. PROTECT PERIMETER INDUCTION UNITS DURING CONSTRUCTION.
6. PATCH WALLS AS REQUIRED FOR REMOVAL/RELOCATION OF EXISTING POWER
AND DATA SYSTEMS. SEE ELECTRICAL DRAWINGS FOR LOCATIONS.
7. PATCH WALLS AS REQUIRED FOR INSTALLATION OF NEW POWER AND DATA
SYSTEMS. SEE ELECTRICAL DRAWINGS FOR LOCATIONS.
8. PREPARE EXISTING FLOORS TO RECEIVE NEW FLOOR FINISHES PER
SPECIFICATIONS AND FINISH MATERIAL MANUFACTURERS REQUIREMENTS.
9. WHERE EXISTING STRUCTURAL STEEL FIREPROOFING IS DAMAGED BY WORK,
PATCH AS REQUIRED TO RESTORE 2 HOUR FIRE RATING.
10. FLOOR LEVELING REQUIREMENTS:
GENERAL:
ADD SELF LEVELING UNDERLAYMENT AS REQUIRED TO PROVIDE LOCALIZED
LEVELING AND REPAIRS TO CONDITION IN ACCORDANCE WITH FLOORING
MATERIAL MANUFACTURER REQUIREMENTS.
AT FOLDING WALLS:
PROVIDE LOCALIZED LEVELING ALONG PATH OF FOLDING TO BRING FLOOR
INTO COMPLIANCE WITH MANUFACTURER'S FLOOR LEVEL REQUIREMENTS.
LEGEND
NEW GYP BOARD
PARTITION
EXISTING PARTITION
TO REMAIN
AREAS OUT OF GENERAL
ARCHITECTURAL SCOPE.
PUBLIC CORRIDOR - EXISTING
TO REMAIN - NO WORK
ANTICIPATED EXCEPT UTILITY
CONNECTIONS AS
REFERENCED ON MEP
DRAWINGS - REPAIR / REPLACE
AS REQUIRED
NEW DEMOUNTABLE PARTITION
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
A131
JCK 31ST FLOOR - FLOOR PLAN
BS/TS Checker
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
1/8" = 1'-0"
LEVEL 31 - FLOOR PLAN
OGC PANTRY
31038
PRINT/COPY/LIBRARY AREA
31070
COATS
31128
IDF
31034
OGC OFFICE
31042
OGC OFFICE
31046
OGC OFFICE
31050
OGC OFFICE
31052
OGC OFFICE
31054
OGC OFFICE
31058
OGC OFFICE
31062
OGC OFFICE
31066
OGC OFFICE
31068
OGC OFFICE
31072
OGC OFFICE
31074
OGC OFFICE
31076
OGC OFFICE
31078
OGC OFFICE
31082
OGC OFFICE
31086
OGC OFFICE
31092
OGC OFFICE
31096
OGC OFFICE
31100
OGC OFFICE
31104
OGC OFFICE
31106
OGC OFFICE
31108
OGC OFFICE
31112
OGC OFFICE
31114
DEPUTY CHIEF
COUNSEL OFFICE
31118
OGC OFFICE
31040
OGC OFFICE
31044
OGC OFFICE
31048
OGC OFFICE
31056
OGC OFFICE
31060
OGC OFFICE
31064
OGC OFFICE
31080
OGC OFFICE
31084
OGC OFFICE
31090
OGC OFFICE
31094
OGC OFFICE
31098 OGC OFFICE
31102
OGC HUDDLE
31116
CHIEF COUNSEL
OFFICE
31120
CORRIDOR
31126
OGC COPY/MAILING
ROOM
31036
OGC OFFICE
31110
RECEPTION
31122
CORRIDOR
31124
2' - 9 1/2"
4' - 0"
10' - 3 1/2" 3' - 3" 7' - 1" 3' - 6"
10' - 7" 2' - 1" 8' - 6"
14' - 5"
2' - 5"8' - 2"
7' - 9"
/2
ALIGN
ALIGN
ALIGNALIGN
ALIGN
/2
A131.1
Sim
CENTER PARTITION ON MULLION OR
COLUMN (TYP.)
UNLESS NOTED OTHERWISE
-SEE DETAIL 1/A-500
12' - 9"
K
ALIGN
A133.1
Sim
P1
P1
CONSTRUCT NEW TYPE P1 PARTITION IN SAME
LOCATION AS PREVIOUS DEMOLISHED
PARTITION -ALIGN NEW GYP. BOARD FINISH FACE
TO THAT OF EXISTING COLUMNS
P1
GC TO CONFIRM EXISTING
PARTITION IS BUILT TO UNDERSIDE
OF DECK - MODIFY/AUGMENT
CONSTRUCTION AS REQUIRED
7' - 1"
/2
H
CENTER NEW WALL ON
MULLION AT EXTERIOR
CURTAIN WALL U.N.O.,
TYP.
CENTER NEW WALL ON
COLUMN U.N.O., TYP.
EXISTING WALL TO REMAIN
CONTINUOUS
ACOUSTICAL SEALANT
AT EACH SIDE
EXISTING HVAC
INDUCTION UNIT TO
REMAIN
SCRIBE GYPSUM BOARD
TO HVAC INDUCTION
UNIT SPACER AND TAPE
JOINT
PARTITION TYPE PER
PLAN
CONTINUOUS BLACK
NEOPRENE TAPE SPACER -
ONE SIDED STICKY SIDE AT
CASING BEAD.
DO NOT FASTEN SPACER
TO STUD
DO NOT FASTEN STUD TO
MULLION
CONTINUOUS L CASING BEAD
AT EACH SIDE
EXISTING EXTERIOR
CURTAIN WALL SYSTEM
PARTITION TYPE PER PLAN
EDGE BEAD
ACOUSTICAL SEALANT BOTH SIDES -
PAINT TO MATCH WALL
EXISTING GYP. BOARD FINISH AT
COLUMN - PAINT
CL PARTITION AND MULLION
NEW ACOUSTIC INSULATION TO BE
ADDED INSIDE VOID BENEATH
CONVECTOR COVER IN LINE WITH
NEW PARTITIONS - TYP.
GENERAL NOTES
1. ALL GYP BOARD PARTITIONS TO BE TYPE P3 EXCEPT WHERE NOTED
OTHERWISE.
2. ALL DIMENSIONS ARE TO FINISH FACE UNLESS NOTED OTHERWISE.
3. DENOTES EXTENT OF TYPE P1 WALL CONSTRUCTION
4. P4 PARTITIONS WHERE BACK OF WALL IS NOT ACCESSIBLE
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
A131.1
JCK 31ST FLOOR - DIMENSION PLAN
BS/TS Checker
Description Date
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
1/8" = 1'-0"
LEVEL 31 - DIMENSION PLAN
1 1/2" = 1'-0"
TYPICAL PLAN DETAIL AT
CURTAINWALL AND COLUMN
RF-1BFP-1
TP-1
ABCDEFGHJ
OGC PANTRY
31038
OGC COPY/MAILING ROOM
31036
PRINT/COPY/LIBRARY AREA
31070
IDF
31034
OGC OFFICE
31042
OGC OFFICE
31046
OGC OFFICE
31050
OGC OFFICE
31052
OGC OFFICE
31054
OGC OFFICE
31058
OGC OFFICE
31062
OGC OFFICE
31066
OGC OFFICE
31068
OGC OFFICE
31072
OGC OFFICE
31074
OGC OFFICE
31076
OGC OFFICE
31078
OGC OFFICE
31082
OGC OFFICE
31086
OGC OFFICE
31092
OGC OFFICE
31096
OGC OFFICE
31100
OGC OFFICE
31104
OGC OFFICE
31106
OGC OFFICE
31108
OGC OFFICE
31112
OGC OFFICE
31114
DEPUTY CHIEF COUNSEL OFFICE
31118
OGC OFFICE
31040
OGC OFFICE
31044
OGC OFFICE
31048
OGC OFFICE
31056
OGC OFFICE
31060
OGC OFFICE
31064
OGC OFFICE
31080
OGC OFFICE
31084
OGC OFFICE
31090
OGC OFFICE
31094
OGC OFFICE
31098
OGC OFFICE
31102
OGC HUDDLE
31116
CHIEF COUNSEL OFFICE
31120
Department Legend
OGC
P1 - OGC
P1 - OGC
28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"
OGC OFFICE
31110
CORRIDOR
31126
CORRIDOR
31124
WS1
WS1
T#
C# C# C#
C#C#C#
C# C#
C#
C#T4C#
OF1
OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1
OF1 OF1
OF1 OF1 OF1
OF1 OF1 OF1 OF1
OF1 OF1 OF1
OF1
S1 S1 S1 S1 S6 S6 S6 S6S6 S6 S6 S6
K
FURNITURE LEGEND
C# CHAIR TYPE "X" TO BE IDENTIFIED BY FURNITURE
DESIGNER
CX BENCH AT LOCKER ROOM
T1 CONFERENCE TABLE
T2 SMALL CONFERENCE TABLE
T3 CAFE TABLE
T4 RECEPTION GUEST TABLE
T5 FOLDING / NESTING TABLE ON CASTERS
T# TABLE TYPE "X"
WS1 6X8 WORK STATION W/ ADJUSTABLE HEIGHT DESK
WS2 6X6 WORK STATION W/ ADJUSTABLE HEIGHT DESK
BS1 BENCHING STATION (SINGLE)
BS2 BENCHING STATION ROW W/ CENTER SPINE
S1 LATERAL FILES W/ TOP FOR WORK SURFACE
S2 SERVING CREDENZA
S3 AV CREDENZA
S4 OPEN SHELVING - FREE STANDING
S5 WALL SHELVING - IT STORAGE
S6 LIBRARY STORAGE
S7 WARDROBE LOCKERS
S8 FIVE DRAWER FILE CABINET
S9 STORAGE CABINET
L1 LECTERN
OF1 OFFICE SETUP 1 - 6X8 ADJUSTABLE HEIGHT DESK W/
RETURN, WARDROBE, TASK CHAIR, GUEST CHAIR(S)
P1 - XXX MULTI-FUNCTION PRINTER - DEPT. DESIGNATION
P2 - XXX NETWORK DESKTOP PRINTER - DEPT. DESIGNATION
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
AF131
JCK 31ST FLOOR - FURNITURE PLAN (NIC)
BS/TS Checker
1/8" = 1'-0"
LEVEL 31 - FURNITURE PLAN (NIC)
0' 4' 8' 16' 32'
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
PLAN PROVIDED FOR FURNITURE COORDINATION PURPOSES WITH UTILITIES, SEE SEPARATE GSA FURNITURE DRAWINGS AND SPECIFICATIONS FOR FURNITURE SCOPE OF WORK
P
U
PD
N
ABCDEFGHJ
MDF / LAN
33048
EVIDENCE
33046
HEARING ROOM
33044C
PRETRIAL ROOM
33044A
SEQUESTER ROOM
33044B
OCR OFFICE
33054
OCR OFFICE
33056
OCR OFFICE
33058
OCR OFFICE
33064
OCR OFFICE
33066
OCR OFFICE
33068
OCR OFFICE
33070
OCR OFFICE
33072
CMS UNION OFFICE
33074
OGC OFFICE /
HUDDLE
33040
OGC OFFICE /
HUDDLE
33038
CMS HUDDLE
33078
COPY
33080
33082
HSPD - 12
33092
SUPPLIES STORAGE
33094
OUTREACH
STORAGE
33096
CMS OFFICE
33102
CMS OFFICE
33100
CMS OFFICE
33098
CONFERENCE ROOM
33090
CMS OFFICE
33088
CMS OFFICE
33086
CMS OFFICE
33084
EXECUTIVE CONF. ROOM
33106
CMS RA OFFICE
33108
CMS OFFICE
33112
CMS HUDDLE
33110
CMS OFFICE
33008
CMS HUDDLE
33010
CMS OFFICE
33006
CMS OFFICE
33004
CMS OFFICE
33002
COLLABORATION AREA
33014
BREAK
33016
PANTRY
33005
SUPPLIES / LOCKER
STORAGE
33026
CMS HUDDLE
33028
CMS OFFICE
33024
CMS OFFICE
33020
CMS OFFICE
33022
CMS FOCUS
33032
CMS FOCUS
33034
MULTIPURPOSE ROOM
33007
IT STORAGE /
WORKSHOP
33001
SERVER
33003
CONF. FURNITURE
STORAGE
33007A
OPEN OFFICE
33030
CORRIDOR
330C
OPEN OFFICE
33018
CORRIDOR
330B
OPEN OFFICE
33012
OPEN OFFICE
33114
CORRIDOR
330A
OPEN OFFICE
33036
CORRIDOR
330D
OPEN OFFICE
33076
CORRIDOR
330F
OPEN OFFICE
33104
CORRIDOR
330G
CORRIDOR
330E
3' - 0"
ALIGN
28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"
33028
33024 33014.2
33007.2
33007A
33058
33048
330E
33044C
33030
33001.1
33001.2
33003
CMS FOCUS
33118
CMS FOCUS
33116
ALIGN FACE
OF STUD WITH
COLUMN.
OGC OFFICE /
HUDDLE
33042
A400
A400 5
A400
33032
33034
A131.1
A400 8
A400
OCR MEETING ROOM
33050
3300433006
AV CLOSET
33007B
33014.1
33026
3302033022
33056
33054
33080 33082 33092
33094 33096
33044B
33044A
33116
33118
33036B
COATS
33036B 33000
33104
330F
A401
33074
CORRIDOR
33076A
33046
33050
33016.2
330H
A400
11A400
A402
FOLDING PANEL
PARTITION D
FOLDING
PANEL
PARTITION E
A500
TYP.
FOLDING PANEL
PARTITION C
COATS
33093
33093
CORRIDOR
330H
CORRIDOR
330J
A400
A400
33075
CLOSET
33075
A40015
33076
33007.1
33007B
A401
A402
K
33008
33010
33064 33066 33068 33070 33072 33084 33086 33088 33098 33100 33102
33112
33106 33108
33090.1 33090.2
33016.1
33087 33089 33090
33078
33110
A603
CORRIDOR
33000
CONFIRMATION OF EXISTING WALL
CONSTRUCTION REQUIRED -
SOME MODIFICATION MAY BE
REQUIRED TO ACCOMMODATE
LATERAL ROUTING OF NEW
INSULATED PLUMBING PIPING
OCR COPY/FILE/SHRED
33052
OCR OFFICE
33060
OCR OFFICE
33062
A500
3306233060
33052
31127
33002
LEGEND
NEW GYP BOARD
PARTITION
EXISTING PARTITION
TO REMAIN
AREAS OUT OF GENERAL
ARCHITECTURAL SCOPE.
PUBLIC CORRIDOR - EXISTING
TO REMAIN - NO WORK
ANTICIPATED EXCEPT UTILITY
CONNECTIONS AS
REFERENCED ON MEP
DRAWINGS - REPAIR / REPLACE
AS REQUIRED
NEW DEMOUNTABLE PARTITION
GENERAL NOTES
1. REFER TO SHEET A131.1 FOR WALL LAYOUT AND WALL TYPE INFORMATION
2. PROVIDE BLOCKING IN WALLS AT WALL MOUNTED EQUIPMENT LOCATIONS -
REFER TO MEP DRAWINGS.
3. ALL COAT CLOSETS TO RECEIVE HANGING ROD AND SHELF.
4. PROTECT EXTERIOR WINDOW TREATMENTS/ BLINDS TO REMAIN FREE FROM
DUST AND DEBRIS DURING DEMOLITION AND CONSTRUCTION.
5. PROTECT PERIMETER INDUCTION UNITS DURING CONSTRUCTION.
6. PATCH WALLS AS REQUIRED FOR REMOVAL/RELOCATION OF EXISTING POWER
AND DATA SYSTEMS. SEE ELECTRICAL DRAWINGS FOR LOCATIONS.
7. PATCH WALLS AS REQUIRED FOR INSTALLATION OF NEW POWER AND DATA
SYSTEMS. SEE ELECTRICAL DRAWINGS FOR LOCATIONS.
8. PREPARE EXISTING FLOORS TO RECEIVE NEW FLOOR FINISHES PER
SPECIFICATIONS AND FINISH MATERIAL MANUFACTURERS REQUIREMENTS.
9. WHERE EXISTING STRUCTURAL STEEL FIREPROOFING IS DAMAGED BY WORK,
PATCH AS REQUIRED TO RESTORE 2 HOUR FIRE RATING.
10. FLOOR LEVELING REQUIREMENTS:
GENERAL:
ADD SELF LEVELING UNDERLAYMENT AS REQUIRED TO PROVIDE LOCALIZED
LEVELING AND REPAIRS TO CONDITION IN ACCORDANCE WITH FLOORING
MATERIAL MANUFACTURER REQUIREMENTS.
AT FOLDING WALLS:
PROVIDE LOCALIZED LEVELING ALONG PATH OF FOLDING TO BRING FLOOR
INTO COMPLIANCE WITH MANUFACTURER'S FLOOR LEVEL REQUIREMENTS.
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
A133
JCK 33RD FLOOR - FLOOR PLAN
BS/TS Checker
Description Date
50% DESIGN DEVELOPMENT 3/3/22
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
1/8" = 1'-0"
LEVEL 33 - FLOOR PLAN
P
U
PD
N
B F
P -1
BFP-1
ABCDEFGHJ
MDF / LAN
33048
EVIDENCE
33046
HEARING ROOM
33044C
PRETRIAL ROOM
33044A
SEQUESTER ROOM
33044B
OCR OFFICE
33054
OCR OFFICE
33056
OCR OFFICE
33058
OCR OFFICE
33064
OCR OFFICE
33066
OCR OFFICE
33068
OCR OFFICE
33070
OCR OFFICE
33072
CMS UNION OFFICE
33074
OGC OFFICE /
HUDDLE
33040
OGC OFFICE /
HUDDLE
33038
CMS HUDDLE
33078
COPY
33080
33082
HSPD - 12
33092
SUPPLIES STORAGE
33094
OUTREACH
STORAGE
33096
CMS OFFICE
33102
CMS OFFICE
33100
CMS OFFICE
33098
CONFERENCE ROOM
33090
CMS OFFICE
33088
CMS OFFICE
33086
CMS OFFICE
33084
EXECUTIVE CONF. ROOM
33106
CMS RA OFFICE
33108
CMS OFFICE
33112
CMS HUDDLE
33110
CMS OFFICE
33008
CMS HUDDLE
33010
CMS OFFICE
33006
CMS OFFICE
33004
CMS OFFICE
33002
COLLABORATION AREA
33014
BREAK
33016
PANTRY
33005
SUPPLIES / LOCKER
STORAGE
33026
CMS HUDDLE
33028
CMS OFFICE
33024
CMS OFFICE
33020
CMS OFFICE
33022
CMS FOCUS
33032
CMS FOCUS
33034
MULTIPURPOSE ROOM
33007
IT STORAGE /
WORKSHOP
33001
SERVER
33003
CONF. FURNITURE
STORAGE
33007A
OPEN OFFICE
33030
CORRIDOR
330C
OPEN OFFICE
33018
CORRIDOR
330B
OPEN OFFICE
33012
OPEN OFFICE
33114
CORRIDOR
330A
OPEN OFFICE
33036
CORRIDOR
330D
OPEN OFFICE
33076
CORRIDOR
330F
OPEN OFFICE
33104
CORRIDOR
330G
CORRIDOR
330E
CMS FOCUS
33118
CMS FOCUS
33116
OGC OFFICE /
HUDDLE
33042
OCR MEETING ROOM
33050
AV CLOSET
33007B
COATS
33036B
CORRIDOR
33076A
COATS
33093
CORRIDOR
330H
CORRIDOR
330J
EQ.EQ. 9' - 2"
3' - 3"
H O
L D
H O
L D
4' - 0" 13' - 4 1/2"
28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"
10' - 0"
4' - 6" 11' - 4"
4' - 0" 13' - 4 1/2"
/2
4' - 3 1/2"
/2
/2
6' - 6"
/2
14' - 0"
/2
3' - 3" 3' - 10 1/2"
1' - 6"
/2
9' - 6"
2' - 0" 8' - 11" 8' - 11"
3' - 10"
4' - 5" 7' - 4"
5' - 4"
/2
/2
13' - 1"
10' - 2 1/2"
ALIGN
ALIGN
ALIGN
ALIGNALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
PERIMETER PARTITIONS
CENTER ON MULLIONS OR
COLUMN LINES UNLESS
NOTED OTHERWISE
A133.1
A133.1
3' - 2"
ALIGN
ALIGN
A L
IG
N 5
" ALIGN ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
/2
ALIGN
A L
IG
N
ALIGN
ALIGN
ALIGN
A40015
1' - 1"
K
MONITOR MONITOR
M O
N
IT
O R
M O
N
IT
O R
M O
N
IT
O R
(2) MONITORS
TYP. TYP.
A131.1
Sim
WALL
MOUNTED
MONITORS -
REFER TO AV
DRAWINGS
TYP.
NOTE: SINK DRAIN PIPE
ROUTING WILL NOT CLEAR
EXISTING STRUCTURE AT 32ND
FLOOR AND WILL REQUIRE THAT
(1) NEW PENETRATION BE CUT
THROUGH EXISTING STEEL
FRAMING - ENGINEERING OF
THESE CONDITIONS IS NOT YET
COMPLETE
NOTE: SINK DRAIN PIPE ROUTING
WILL NOT CLEAR EXISTING
STRUCTURE AT 32ND FLOOR AND
WILL REQUIRE THAT (2) NEW
PENETRATIONS BE CUT THROUGH
EXISTING STEEL FRAMING -
ENGINEERING OF THESE
CONDITIONS IS NOT YET
COMPLETE
CENTER WALL ON COLUMN LINE
P1
P1
P1
P1
CL PARTITION AND
EXTERIOR MULLION
A
+ - 1' - 6 1/2"
CENTER NEW WALL ON
MULLION AT EXTERIOR
CURTAIN WALL U.N.O.,
TYP.
CONTINUOUS
ACOUSTICAL SEALANT
AT EACH SIDE
CONTINUOUS BLACK
NEOPRENE TAPE SPACER -
ONE SIDED STICKY SIDE AT
CASING BEAD.
DO NOT FASTEN SPACER
TO STUD
DO NOT FASTEN STUD TO
MULLION
CONTINUOUS L CASING BEAD
AT EACH SIDE
EXISTING EXTERIOR
CURTAIN WALL SYSTEM
CL PARTITION AND
EXTERIOR MULLION
PARTITION TYPE PER
PLAN
SCRIBE GYPSUM BOARD
TO HVAC INDUCTION
UNIT SPACER AND TAPE
JOINT
EXISTING HVAC
INDUCTION UNIT TO
REMAIN
GENERAL NOTES
1. ALL GYP BOARD PARTITIONS TO BE TYPE P3 EXCEPT WHERE NOTED
OTHERWISE.
2. ALL DIMENSIONS ARE TO FINISH FACE UNLESS NOTED OTHERWISE.
3. DENOTES EXTENT OF TYPE P1 WALL CONSTRUCTION
4. P4 PARTITIONS WHERE BACK OF WALL IS NOT ACCESSIBLE
GREAT LAKES REGION 5
SENSITIVE BUT UNCLASSIFIED
(SBU)
PROPERTY OF
THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice Properly destroy or return documents when no longer needed
DRAWING
NO.
DRAWING
TITLE
PUBLIC BUILDING SERVICE
OFFICE OF PROPERTY
DEVELOPMENT
REGION 5 CHICAGO, ILLINOIS
BLDG.
GENERAL SERVICES ADMINISTRATION
PROJECT
LOCATION
PCN
DRAWN
CONTRACT
CHECKED
FILE NUMBER: IN1710322_N1630165_ _1
ENGINEER
900 NORTH FRANKLIN STREET, SUITE 304
INTERACTIVE DESIGN
CHICAGO, IL 60610 - USA
Tel: 312-482-8866
ARCHITECT
ARUP
IL0236FC
CHICAGO, ILLINOIS
23456789101112131415
ABCDE
ENVIRONMENTAL
600 WEST VANBUREN STREET
CARNOW CONIBEAR & ASSOC.
CHICAGO, IL 60607 - USA
Tel: 312-762-2956
35 EAST WACKER DRIVE, SUITE 1800
CHICAGO, IL 60601 - USA
Tel: 312-849-5610
DEPARTMENT OF STATE CHICAGO
RELOCATION PROJECT - JCK
A133.1
JCK 33RD FLOOR - DIMENSION PLAN
BS/TS Checker
Description Date
100% DESIGN DEVELOPMENT 4/22/22
75% CONSTRUCTION DOCUMENTS 7/1/22
1/8" = 1'-0"
LEVEL 33 - DIMENSION PLAN
1 1/2" = 1'-0"
TYPICAL PLAN DETAIL AT INTERIOR
WALL AND DEMOUNTABLE PARTITON
1 1/2" = 1'-0"
TYPICAL PLAN DETAIL AT EXTERIOR
WALL AND DEMOUNTABLE PARTITION
7' - 7"
R. O. OF SLIDING DOOR ASSEMBLY TO BE VERIFIED BY DEMOUNTABLE PARTITION MANUFACTURER
P
U
PD
N
ABCDEFGHJ
RECEPTION
MDF / LAN
33048
EVIDENCE
33046
HEARING ROOM
33044C
PRETRIAL ROOM
33044A
SEQUESTER ROOM
33044B
OCR MEETING ROOM
33050
OCR OFFICE
33054
OCR OFFICE
33056
OCR OFFICE
33058
OCR OFFICE
33068
OCR OFFICE
33070
OCR OFFICE
33072
CMS UNION OFFICE
33074
OGC OFFICE / HUDDLE
33040
OGC OFFICE / HUDDLE
33038
CMS HUDDLE
33078
COPY
33080
33082
HSPD - 12
33092
SUPPLIES STORAGE
33094
OUTREACH STORAGE
33096
CMS OFFICE
33102
CMS OFFICE
33100
CMS OFFICE
33098
CONFERENCE ROOM
33090
CMS OFFICE
33088
CMS OFFICE
33086
CMS OFFICE
33084
EXECUTIVE CONF. ROOM
33106
CMS RA OFFICE
33108
CMS HUDDLE
33110
CMS OFFICE
33008CMS HUDDLE
33010
CMS OFFICE
33006
CMS OFFICE
33004
CMS OFFICE
33002
COLLABORATION AREA
33014
BREAK
33016
PANTRY
33005
SUPPLIES / LOCKER STORAGE
33026
CMS HUDDLE
33028
CMS OFFICE
33024
CMS OFFICE
33020
CMS OFFICE
33022
CMS…