HHS Chicago Federal Backfill - 75_ CD - JCK Drawings 07-01-11.pdf

PDF 43 MB Posted

Attached to
GC Services for the HHS Chicago Federal Backfill Project
Solicitation number
47PF0022R0001
Issued by

About this file

This document announces a solicitation for general construction services for the Health and Human Services Chicago Federal Backfill Project. The General Services Administration seeks a general construction contractor to provide construction and renovation services at the John C. Kluczynski and Ralph H. Metcalfe Federal Buildings in Chicago, Illinois to consolidate approximately 122,389 square feet of leased office space into 52,620 square feet of federal space. Eligible firms must be small businesses. The total estimated construction cost is between $10-20 million. The contract will be a firm fixed-price award. The solicitation package will be available on July 12th and proposals will be due on August 11th. The award is targeted for November 2022 with a 250-day performance period ending no later than October 11th, 2023. Attendance at the pre-proposal conference is recommended to understand project requirements. Interested parties should monitor the System for Award Management website and contact the named contracting officer with any questions.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

GENERAL SERVICES ADMINISTRATION

REGION 5

CLIENT

Tel: +1.312.482.8866

ARCHITECT

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel:

CHICAGO, ILLINOIS 60604 - USA

230 SOUTH DEARBORN

ARUP

CHICAGO, ILLINOIS 60601 - USA

ENGINEER

35 EAST WACKER DRIVE, SUITE 1800

Tel: +1.312.849.5610

CARNOW CONIBEAR & ASSOC

CHICAGO, ILLINOIS 60607 - USA

ENVIRONMENTAL CONSULTANTS

600 WEST VAN BUREN, SUITE 500

Tel: +1.312.782.4486

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

G000

JCK COVER

BS/TS LW/CY

HHS CHICAGO FEDERAL BACKFILL PROJECT

230 SOUTH DEARBORN STREET

CHICAGO, ILLINOIS 60604

JOHN C. KLUCZYNSKI FEDERAL BUILDING

ISSUE FOR

75% CONSTRUCTION DOCUMENTS

July 1, 2022

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

ABBREVIATIONS:

ACT. CEILING TILE

ALUM. ALUMINUM

ANOD. ANODIZED

CMU. CONCRETE MASONRY UNIT

CPT. CARPET PLANKS

CT. PORCELAIN/CERAMIC TILE

E.J. EXPANSION JOINT

ELEV. ELEVATOR

EQP. EQUIPMENT

ES. EXPOSED STRUCTURE

EXP. EXPOSED TO ABOVE

EXIST. EXISTING

F.E.C FIRE EXTINGUISHER CABINET

FP. FACTORY PAINT

FRP. FIBERGLASS REINFORCED PLASTIC

GALV. GALVANIZED

GL GLASS

GYP. BD / GYP.GYPSUM BOARD

HM HOLLOW METAL

JAN. JANITORS CLOSET

LH. LEFT HAND

LHR. LEFT HAND REVERSE

LVT. LUXURY VINYL TILE

MECH. MECHANICAL

MCP. METAL CEILING PANEL

MTL. METAL

NS_VCT NON-STATIC VINYL COMPOSITION TILE

N.I.C. NOT IN CONTRACT

PLAS. PLASTER

PT. PAINT

RB. RUBBER BASE

RM. ROOM

SS STAINLESS STEEL

TERR. TERRAZZO

TYP. TYPICAL

UON. UNLESS OTHERWISE NOTED

WD. WOOD

SYMBOLS:

- SECTION TAG

- ELEVATION TAG

- CALLOUT TAG

- NORTH ARROW

- COLUMN GRID

- ROOM TAG

- DOOR TAGS

- WALL TAG

A101

Ref

A101

1 Ref

R e f

R e f

1 Ref

Room name

1i

Ref

A101

GENERAL PROJECT NOTES:

1. FIELD VERIFY ALL DIMENSIONS PRIOR TO PREPARATION OF SHOP DRAWING SUBMITTALS.

2. DO NOT SCALE DRAWINGS.

3. VERIFY EXISTING FIELD CONDITIONS AND PROMPTLY REPORT ANY DISCREPANCIES FROM

THE DRAWINGS TO THE ARCHITECT.

4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE BRACING AND BLOCKING WITHIN

PARTITIONS AND CEILINGS RECEIVING MILLWORK, GRAB BARS, HARDRAILS, SHELVING,

MONITORS, SIGNAGE, TOILET ACCESSORIES, FURNITURE HANGER STRIPS, BLINDS,

MARKER BOARDS, ETC.

5. THE CONTRACTOR SHALL COORDINATE FINISHED GYPSUM BOARD PARTITION WITH

DIMENSIONAL INSTALLATION REQUIREMENTS OF EQUIPMENT AND MILLWORK.

6. IN THE CASE OF CONFLICTING REQUIREMENTS, THE MOST STRINGENT SHALL APPLY.

7. ALL SS TO BE TYPE 304 UNLESS NOTED OTHERWISE.

8. ENSURE ALL EXPOSED EXISTING GYP. BD. WALL WITHIN PROJECT (TO REMAIN) RECEIVE

NEW PAINT

9. PROVIDE SILICONE SEALANT JOINTS AT JUNCTION OF ALL PLUMBING FIXTURES &

COUNTERTOPS TO A WALL SURFACE.

10. IN LOCATIONS WHERE EXISTING FIRE PROOFING IS REMOVED, PROVIDE NEW FIRE

PROOFING PER SPECIFICATION 07 8100.

11. IF INTUMESCENT FIRE PROOFING IS NEEDED TO ALLOW FOR CLEARANCE OF MEP ITEMS

BELOW GIRDERS, THEN PROVIDE CAFCO SPRAYFILM WB5 OR WB7 OR EQUIVALENT.

LCLC

LC

LC

THERMOSTAT LIGHT SWITCH ELECTRICAL OUTLET DATA OUTLET

COUNTER/ BENCH/ CASEWORK - AT GALLEY/ LAVATORY/ WORK FILE RM

TELEPHONE OUTLET

DATA OUTLET

ELECTRICAL OUTLET

RACEWAY (@ TOP OF

BACKSPLASH, TYP.)

U O

N

1'

U O

N

1'

"3'

2'

0" A

D A

3'

3'

AT LOCATIONS

NOT ADJACENT

TO LIGHT SWITCH

M A

X

1' - 0"

THERMOSTAT

(IF REQ.)

1ST

LIGHT SWITCH

SWITCHING LAYOUT

DOOR OR SWING

SECONDARY

CONTROL

(IF REQ.)

2ND & 3RD

LIGHT SWITCHS

(IF REQ.)

6" 6"

6" 3'

M A

X F

O R

O P

E R

A B

LE

P

A R

T S

4'

S E

E D

O O

R S

C H

E D

U

LE

LC

LC

LC

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

G100

GENERAL NOTES / SYMBOLS /

ABBREVIATIONS

BS/TS Checker

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

ARCHITECTURAL

LS031 JCK 31ST FLOOR - LIFE SAFETY SHEET

LS033 JCK 33RD FLOOR - LIFE SAFETY SHEET

D131 JCK 31ST FLOOR - DEMOLITION PLAN

D133 JCK 33RD FLOOR - DEMOLITION PLAN

D231 JCK 31ST FLOOR - DEMOLITION REFLECTED CEILING PLAN

D233 JCK 33RD FLOOR - DEMOLITION REFLECTED CEILING PLAN

A131 JCK 31ST FLOOR - FLOOR PLAN

A131.1 JCK 31ST FLOOR - DIMENSION PLAN

AF131 JCK 31ST FLOOR - FURNITURE PLAN (NIC)

A133 JCK 33RD FLOOR - FLOOR PLAN

A133.1 JCK 33RD FLOOR - DIMENSION PLAN

AF133 JCK 33RD FLOOR - FURNITURE PLAN (NIC)

A231 JCK 31ST FLOOR - REFLECTED CEILING PLAN

A233 JCK 33RD FLOOR - REFLECTED CEILING PLAN

A400 JCK - INTERIOR ELEVATIONS

A401 JCK - FOLDING PARTITION ENLARGED PLAN AND DETAILS

A402 JCK - FOLDING PARTITION ENLARGED PLAN AND DETAILS

A500 JCK - STANDARD PARTITION TYPES AND DETAILS

A600 JCK - ROOM FINISH SCHEDULE - LEVEL 31

A601 JCK - ROOM FINISH SCHEDULE - LEVEL 33

A602 JCK - DOOR SCHEDULE - LEVEL 31

A603 JCK - DOOR SCHEDULE - LEVEL 33

A604 JCK - SIGNAGE SCHEDULE

A605 JCK - WORKSTATION SIGNAGE SCHEDULE

A606 JCK - 31ST FLOOR SIGNAGE PLAN

A607 JCK - 33RD FLOOR SIGNAGE PLAN

GENERAL

G000 JCK COVER

G100 GENERAL NOTES / SYMBOLS / ABBREVIATIONS

MECHANICAL

M-000 JCK MECHANICAL ABBREVIATIONS, SYMBOLS, GENERAL NOTES AND

DRAWING LIST

M-131 JCK LEVEL 31 - MECHANICAL DEMOLITION PLAN

M-133 JCK LEVEL 33 - MECHANICAL DEMOLITION PLAN

M-331 JCK LEVEL 31 - MECHANICAL DUCTWORK PLAN

M-333 JCK LEVEL 33 - MECHANICAL DUCTWORK PLAN

M-431 JCK LEVEL 31 - MECHANICAL PIPING PLAN

M-433 JCK LEVEL 33 - MECHANICAL PIPING PLAN

M-531 JCK LEVEL 31 - MECHANICAL CONTROLS PLAN

M-533 JCK LEVEL 33 - MECHANICAL CONTROLS PLAN

M-600 JCK MECHANICAL SCHEDULES

M-800 JCK MECHANICAL DETAILS

M-801 JCK MECHANICAL DETAILS

M-802 JCK MECHANICAL DETAILS

ELECTRICAL

E-000 JCK ELECTRICAL ABBREVIATIONS, SYMBOLS, GENERAL NOTES AND

DRAWING LIST

E-131 JCK LEVEL 31 - ELECTRICAL DEMOLITION PLAN

E-131.1 JCK LEVEL 31 - ELECTRICAL LIGHTING DEMOLITION PLAN

E-133 JCK LEVEL 33 - ELECTRICAL DEMOLITION PLAN

E-133.1 JCK LEVEL 33 - ELECTRICAL LIGHTING DEMOLITION PLAN

E-231 JCK LEVEL 31 - ELECTRICAL LIGHTING PLAN

E-233 JCK LEVEL 33 - ELECTRICAL LIGHTING PLAN

E-331 JCK LEVEL 31 - ELECTRICAL POWER PLAN

E-333 JCK LEVEL 33 - ELECTRICAL POWER PLAN

E-333.1 JCK LEVEL 33 - ELECTRICAL IN FLOOR SYSTEM

E-431 JCK LEVEL 31 - TELECOM & SECURITY PLAN

E-433 JCK LEVEL 33 - TELECOM & SECURITY PLAN

E-500 JCK ELECTRICAL ENLARGED PLANS

E-700 JCK ELECTRICAL RISER DIAGRAM

E-800 JCK ELECTRICAL DETAILS

E-801 JCK LOW VOLTAGE DETAILS

E-802 JCK LOW VOLTAGE DETAILS

E-803 JCK LOW VOLTAGE DETAILS

E-900 JCK LIGHTING FIXTURE SCHEDULE AND CONTROLS NARRATIVE

E-901 JCK ENLIGHTING LIGHTING CONTROLS NARRATIVE

E-902 JCK ELECTRICAL PANEL SCHEDULES

PLUMBING

P-000 JCK PLUMBING ABBREVIATIONS, SCHEDULES, SYMBOLS, GENERAL

NOTES AND DRAWING LIST

P-131 JCK LEVEL 31 - PLUMBING DEMOLITION PLAN

P-133 JCK LEVEL 33 - PLUMBING DEMOLITION PLAN

P-230 JCK LEVEL 30 - PLUMBING PLAN

P-231 JCK LEVEL 31 - PLUMBING PLAN

P-232 JCK LEVEL 32 - PLUMBING PLAN

P-233 JCK LEVEL 33 - PLUMBING PLAN

P-400 JCK PLUMBING ENLARGED PLANS AND SECTIONS

P-500 JCK PLUMBING RISER DIAGRAMS

P-800 JCK PLUMBING DETAILS

FIRE PROTECTION

FP-000 JCK FIRE PROTECTION ABBREVIATIONS, SYMBOLS, GENERAL NOTES

AND DRAWING LIST

FP-131 JCK LEVEL 31 - FIRE PROTECTION DEMOLITION PLAN

FP-133 JCK LEVEL 33 - FIRE PROTECTION DEMOLITION PLAN

FP-231 JCK LEVEL 31 - FIRE PROTECTION PLAN

FP-233 JCK LEVEL 33 - FIRE PROTECTION PLAN

FP-800 JCK FIRE PROTECTION DETAILS

DRAWING LIST

FIRE ALARM

FA-000 JCK FIRE ALARM ABBREVIATIONS, SYMBOLS, GENERAL NOTES AND

DRAWING LIST

FA-131 JCK LEVEL 31 - FIRE ALARM DEMOLITION PLAN

FA-133 JCK LEVEL 33 - FIRE ALARM DEMOLITION PLAN

FA-231 JCK LEVEL 31 - FIRE ALARM PLAN

FA-233 JCK LEVEL 33 - FIRE ALARM PLAN

FA-800 JCK FIRE ALARM DETAILS

ACOUSTICS

AC-000 JCK SOUND MASKING ABBREVIATIONS, SYMBOLS, GENERAL NOTES

AND DRAWING LIST

AC-231 JCK LEVEL 31 - SOUND MASKING PLAN

AC-233 JCK LEVEL 33 - SOUND MASKING PLAN

AC-601 JCK SOUND MASKING DETAILS

ACM-131 JCK LEVEL 31 - ASBESTOS ABATEMENT

ACM-133 JCK LEVEL 33 - ASBESTOS ABATEMENT

AUDIOVISUAL

AV-000 JCK AUDIO VISUAL ABBREVIATIONS, SYMBOLS, GENERAL NOTES AND

DRAWING LIST

AV-001 JCK AUDIOVISUAL SCHEDULES

AV-131 JCK LEVEL 31 - AUDIOVISUAL DEMOLITION PLAN

AV-133 JCK LEVEL 33 - AUDIOVISUAL DEMOLITION PLAN

AV-331 JCK LEVEL 31 - AUDIOVISUAL OVERALL PLAN

AV-333 JCK LEVEL 33 - AUDIOVISUAL OVERALL PLAN

AV-431 JCK LEVEL 31 - AUDIOVISUAL EQUIPMENT PLAN

AV-432 JCK LEVEL 31 - AUDIOVISUAL INFRASTRUCTURE PLAN

AV-434 JCK LEVEL 33 - AUDIOVISUAL EQUIPMENT PLAN

AV-435 JCK LEVEL 33 - AUDIOVISUAL INFRASTRUCTURE PLAN

AV-436 JCK LEVEL 33 - AUDIOVISUAL EQUIPMENT RCP

AV-437 JCK LEVEL 33 - AUDIOVISUAL INFRASTRUCTURE RCP

AV-600 JCK AUDIOVISUAL ELEVATIONS, RISER DIAGRAMS

AV-601 JCK AUDIOVISUAL ELEVATIONS, RISER DIAGRAMS

AV-700 JCK AUDIOVISUAL FUNCTIONAL DIAGRAMS

AV-701 JCK AUDIOVISUAL FUNCTIONAL DIAGRAMS

AV-702 JCK AUDIOVISUAL FUNCTIONAL DIAGRAMS

AV-703 JCK AUDIOVISUAL FUNCTIONAL DIAGRAMS

ASBESTOS CONTAINING MATERIAL

ACM-131 JCK LEVEL 31 - ASBESTOS ABATEMENT

ACM-133 JCK LEVEL 33 - ASBESTOS ABATEMENT

ABCDEFGHJ

69 SF

OGC PANTRY

105 SF

OGC COPY/MAILING ROOM

106 SF

PRINT/COPY/LIBRARY AREA

6 SF

COATS

60 SF

IDF

126 SF

OGC OFFICE

118 SF

OGC OFFICE

117 SF

OGC OFFICE

117 SF

OGC OFFICE

118 SF

OGC OFFICE

117 SF

OGC OFFICE

117 SF

OGC OFFICE

118 SF

OGC OFFICE

117 SF

OGC OFFICE

117 SF

OGC OFFICE

118 SF

OGC OFFICE

117 SF

OGC OFFICE

117 SF

OGC OFFICE

118 SF

OGC OFFICE

117 SF

OGC OFFICE

117 SF

OGC OFFICE

118 SF

OGC OFFICE

117 SF

OGC OFFICE

117 SF

OGC OFFICE

118 SF

OGC OFFICE

117 SF

OGC OFFICE

117 SF

OGC OFFICE

118 SF

OGC OFFICE

126 SF

DEPUTY CHIEF COUNSEL OFFICE

116 SF

OGC OFFICE

114 SF

OGC OFFICE

113 SF

OGC OFFICE

113 SF

OGC OFFICE

113 SF

OGC OFFICE

114 SF

OGC OFFICE

117 SF

OGC OFFICE

109 SF

OGC OFFICE

117 SF

OGC OFFICE

117 SF

OGC OFFICE

107 SF

OGC OFFICE

117 SF

OGC OFFICE 121 SF

OGC HUDDLE

131 SF

CHIEF COUNSEL OFFICE

T R

A V

E L

D

IS

T A

N C

E : 1

0"

DEAD END DISTANCE: 34' - 9"

TRAVEL DISTANCE: 147' - 0" TRAVEL DISTANCE: 120' - 0"

106 SF

OGC OFFICE

285 SF

RECEPTION

1065 SF

CORRIDOR

41 SF

CORRIDOR

K

AREAS OUT OF GENERAL

ARCHITECTURAL SCOPE.

TRAVEL DISTANCE

2 HOUR CONSTRUCTION (EXISTING)

SURFACE MOUNTED FIRE EXTINGUISHER LOCATION -

LOCATIONS TO BE COORDINATED WITH AHJ

FEC

OCCUPANCY KEY

OFFICE

CIRCULATION

STORAGE/MECHANICAL

DEAD END DISTANCE

PUBLIC CORRIDOR - THIS

AREA IS OUT OF GENERAL

ARCHITECTURAL SCOPE.

OFFICE - COLLABORATION

SPACES <450 SF

ASSEMBLY

SAFETY AND OCCUPANCY PLAN

CONSTRUCTION TYPE 1-A / EXISTING

FULLY SPRINKLED BUILDING

OCCUPANCY CLASS BUSINESS B

MAX TRAVEL DISTANCE 300'-0"

MAX DEAD END CORRIDOR 50'-0"

EXISTING EGRESS STAIRWAY CAPACITY

31ST FLOOR EGRESS STAIR - NFPA 101 - 7.3.3.1

WIDTH (in) FACTOR

OCCUPANT

CAPACITY

O C

C U

P A

N C

Y C

L A

S S

B

(B

U S

IN

E

S S

EAST STAIR

WEST STAIR

SUBTOTAL

.3

.3

EXIT 1

EXIT 2

TOTAL EXIT CAPACITY 292

31ST FLOOR OCCUPANCY

BASED ON NFPA 101 SF/OCCUPANT - TABLE 7.3.1.2

KEY

1/150

1/500

CIRCULATION

OFFICE

STORAGE/MECHANICAL

TOTAL EXIT CAPACITY 292 > 39 OK

LEVEL 31 OCCUPANCY

1/30121OFFICE - COLLABORATION

SPACES <450 SF

1/150 0ASSEMBLY -

CONFERENCE ROOM USE

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

LS031

JCK 31ST FLOOR - LIFE SAFETY SHEET

BS/TS Checker

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

1/8" = 1'-0"

LEVEL 31 - LIFE SAFETY PLAN

0' 4' 8' 16' 32'

NOTE TO AHJ: ARE FIRE EXTINGUISHERS DESIRED FOR THIS PROJECT?

D N U P

U

PD

N

ABCDEFGHJ

RECEPTION

90 SF

MDF / LAN

531 SF

EVIDENCE

400 SF

HEARING ROOM

262 SF

PRETRIAL ROOM

237 SF

SEQUESTER ROOM

181 SF

OCR MEETING ROOM

121 SF

OCR OFFICE

122 SF

OCR OFFICE

122 SF

OCR OFFICE

124 SF

OCR OFFICE

123 SF

OCR OFFICE

122 SF

OCR OFFICE

122 SF

OCR OFFICE

123 SF

OCR OFFICE

122 SF

CMS UNION OFFICE

120 SF

OGC OFFICE / HUDDLE

119 SF

OGC OFFICE / HUDDLE

130 SF

CMS HUDDLE

126 SF

COPY

97 SF

MAIL

118 SF

HSPD - 12

156 SF

SUPPLIES STORAGE

70 SF

OUTREACH STORAGE

122 SF

CMS OFFICE

123 SF

CMS OFFICE

122 SF

CMS OFFICE

344 SF

CONFERENCE ROOM

124 SF

CMS OFFICE

125 SF

CMS OFFICE

124 SF

CMS OFFICE

251 SF

EXECUTIVE CONF. ROOM

124 SF

CMS RA OFFICE

116 SF

CMS OFFICE

110 SF

CMS HUDDLE

116 SF

CMS OFFICE

108 SF

CMS HUDDLE

122 SF

CMS OFFICE

123 SF

CMS OFFICE

124 SF

CMS OFFICE

370 SF

COLLABORATION AREA

280 SF

BREAK

122 SF

PANTRY

159 SF

SUPPLIES / LOCKER STORAGE137 SF

CMS HUDDLE

122 SF

CMS OFFICE

122 SF

CMS OFFICE

123 SF

CMS OFFICE

56 SF

CMS FOCUS

62 SF

CMS FOCUS

1024 SF

MULTIPURPOSE ROOM

200 SF

SERVER

448 SF

IT STORAGE / WORKSHOP

DEAD END DISTANCE: 30' - 5" DEAD END

DISTANCE: 14' - 1"

DEAD END

DISTANCE: 14' - 1"

DEAD END DISTANCE: 41' - 7"

TRAVEL DISTANCE: 162' - 0"

TRAVEL DISTANCE: 171' - 0"

111 SF

CONF. FURNITURE STORAGE

TRAVEL DISTANCE: 153' - 0"

44 SF

CMS FOCUS

44 SF

CMS FOCUS

121 SF

OGC OFFICE / HUDDLE

K

24 SF

AV CLOSET

SAFETY AND OCCUPANCY PLAN

CONSTRUCTION TYPE 1-A / EXISTING

FULLY SPRINKLED BUILDING

OCCUPANCY CLASS ASSEMBLY A AND BUSINESS B

MAX TRAVEL DISTANCE 300'-0"

MAX DEAD END CORRIDOR 50'-0"

33RD FLOOR OCCUPANCY

BASED ON NFPA 101 SF/OCCUPANT - TABLE 7.3.1.2

KEY

1/150

1/500

10235

CIRCULATION

OFFICE

STORAGE/MECHANICAL

TOTAL EXIT CAPACITY 292 > 286 OK

LEVEL 33 OCCUPANCY

1/301629OFFICE - COLLABORATION

SPACES <450 SF

1/152364 158ASSEMBLY -

CONFERENCE ROOM USE

EXISTING EGRESS STAIRWAY CAPACITY

33RD FLOOR EGRESS STAIR - NFPA 101 - 7.3.3.1

WIDTH (in) FACTOR

OCCUPANT

CAPACITY

O C

C U

P A

N C

Y C

L A

S S

A

B

(A

S S

E M

B L

Y

B U

S

IN

E S

S

EAST STAIR

WEST STAIR

.3

.3

EXIT 1

EXIT 2

TOTAL EXIT CAPACITY 292

AREAS OUT OF GENERAL

ARCHITECTURAL SCOPE.

TRAVEL DISTANCE

2 HOUR CONSTRUCTION (EXISTING)

SURFACE MOUNTED FIRE EXTINGUISHER LOCATION -

LOCATIONS TO BE COORDINATED WITH AHJ

FEC

OCCUPANCY KEY

OFFICE

CIRCULATION

STORAGE/MECHANICAL

DEAD END DISTANCE

PUBLIC CORRIDOR - THIS

AREA IS OUT OF GENERAL

ARCHITECTURAL SCOPE.

OFFICE - COLLABORATION

SPACES <450 SF

ASSEMBLY

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

LS033

JCK 33RD FLOOR - LIFE SAFETY SHEET

BS/TS Checker

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

1/8" = 1'-0"

LEVEL 33 - LIFE SAFETY PLAN

P

U

PD

N

ABCDEFGHJ

5 4

28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"

K

GENERAL NOTES

1. PROTECT EXTERIOR WINDOW TREATMENTS FROM DUST AND DEBRIS DURING

DEMOLITION AND CONSTRUCTION.

2. PROTECT ALL PERIMETER FLOOR MOUNTED FAN-COIL UNITS FROM DUST AND

DEBRIS DURING DEMOLITION, AND CONSTRUCTION.

3. PROTECT ARCHITECTURAL COLUMN CLADDING ON ALL EXTERIOR PERIMETER

COLUMNS FROM DUST, DEBRIS, AND DAMAGE DURING DEMOLITION, AND

CONSTRUCTION.

4. REFER TO THE MEP DISCIPLINE DRAWINGS FOR EXTENT OF MEP SYSTEM DEMOLITION.

5. PROTECT EXISTING WALLS AND FINISHES IN THE ADJACENT NO WORK AREA THAT

INTERFACE WITH THE AREA OF WORK.

6. ASBESTOS CONTAINING MATERIAL:

ASBESTOS WAS CONFIRMED PRESENT IN THE MASTIC BENEATH THE CARPET IN THE

WEST OFFICE AREA (APPROXIMATELY 1300 SF) - SEE HATCHED AREA ON ABOVE PLAN.

REFER TO ABATEMENT DRAWINGS AND PRE-ALTERATION SURVEY IN THE APPENDIX OF

THE PROJECT SPECIFICATIONS

7. ALL EXISTING FURNITURE REMAINING IN THE SUITE AT START OF CONSTRUCTION IS TO

BE REMOVED AND RECYCLED WHERE POSSIBLE OR ELSE DISPOSED OF

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE REMOVED

DEMOLITION KEY NOTE - SEE

KEYNOTE LEGEND

LEGEND

DEMOLITION PHOTO KEY

NOTE - SEE KEYNOTE LEGEND

AREAS OUT OF GENERAL

ARCHITECTURAL SCOPE.

PUBLIC CORRIDOR - EXISTING

TO REMAIN - ANTICIPATED

WORK LIMITED TO PATCH/

REPAIR AS NECESSITATED BY

REMOVAL AND REPLACEMENT

OF SUITE PERIMETER WALL

AND UTILITY CONNECTIONS

ASSOCIATED WITH MEP SCOPE

OF WORK

31ST FLOOR DEMOLITION PHOTOS

2 3

EXISTING

CASEWORK

EXISTING COLUMN

EXISTING

STOREFRONT

EXISTING

CASEWORK

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

D131

JCK 31ST FLOOR - DEMOLITION PLAN

BS/TS LW/CY

1/8" = 1'-0"

LEVEL 31 - DEMO PLAN

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

0' 4' 8' 16' 32'

31ST FLOOR DEMO PLAN KEYNOTE LEGEND

KEYNOTE

NUMBER TEXT

1 EXISTING COLUMN ENCLOSURES TO REMAIN - PATCH TO MATCH ADJACENT FINISH AS EQUIRED WHERE ADJACENT CONDITIONS

ARE REMOVED - REMOVE EXISTING BASE - TYPICAL THROUGOUT

2 REMOVE EXISTING RESILIENT BASE, CARPET, UNDERLAYMENT, AND ADHESIVE DOWN TO SLAB IN PREPARATION FOR NEW FLOOR FINISH - TYPICAL THROUGHOUT ENTIRE SUITE AND BETWEEN FAN COIL UNIT AND CURTAIN WALL

3 REMOVE EXISTING CORRIDOR WALL SYSTEM AND BASE

4 REMOVE EXISTING DOORS, FRAMES AND HARDWARE (INCLUDING SIDELITES WHERE APPLICABLE) THROUGHOUT ENTIRE SUITE

EXCEPT WHERE SPECIFICALLY NOTED TO REMAIN

5 REMOVE EXISTING GYP BOARD PARTITIONS FOR ENTIRE HEIGHT - TYPICAL THROUGHOUT ENTIRE SUITE - AS INDICATED BY

DASHED LINES (REFER TO LEGEND)

6 EXISTING GLAZED STOREFRONT SYSTEM AND ASSOCIATED HARDWARE TO BE REMOVED

7 REMOVE EXISTING CASEWORK AND PLUMBING FIXTURES WHERE APPLICABLE - REFER TO MEP DEMOLTION DRAWINGS FOR

FURTHER INFORMATION

9 REMOVE EXISTING SERVICE WINDOW AND COUNTERTOP AT HIGH DENSITY FILE STORAGE SYSTEM (REFER TO PHOTO #1)

10 DEMOLISH EXISTING PANTRY WITH CASEWORK. SEE MEP FOR PLUMBING DEMOLITION SCOPE (SEE PHOTO #1)

11 DEMOLISH EXISTING CASEWORK. SEE MEP FOR PLUMBING DEMOLITION SCOPE (SEE PHOTO #2)

12 PROTECT EXISTING COLUMNS AND ARCHITECTURAL CLADDING FROM DUST AND DEBRIS DURING DEMOLITION, AND CONSTRUCTION. DEMOLISH AND REPLACE EXISTING VINYL BASE AT ALL COLUMNS. REPAIR, REPAINT, AND REFINISH COLUMN

CLADDING DAMAGED BY DEMOLITION AND CONSTRUCTION, TYP. (SEE PHOTO #3)

13 EXISTING CORRIDOR CARPET TO REMAIN - COVER AND PROTECT AS REQURIED DURING ADJACENT DEMOLITON - DAMAGED

CARPET TILES TO BE REPLACED IN KIND

ASBESTOS CONFIRMED

PRESENT IN THE BLACK

MASTIC BENEATH EXISTING

CARPET SEE ENVIRONMENTAL

DRAWINGS

P

U

PD

N

ABCDEFGHJ

3 3

28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"

6 6 6

5 5

K

12 12

CONFIRMATION OF EXISTING WALL

CONSTRUCTION REQUIRED -

SOME MODIFICATION MAY BE

REQUIRED TO ACCOMMODATE

LATERAL ROUTING OF NEW

INSULATED PLUMBING PIPING

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE REMOVED

DEMOLITION KEY NOTE - SEE

KEYNOTE LEGEND

LEGEND

DEMOLITION PHOTO KEY

NOTE - SEE KEYNOTE LEGEND

AREAS OUT OF GENERAL

ARCHITECTURAL SCOPE.

PUBLIC CORRIDOR - EXISTING

TO REMAIN - ANTICIPATED

WORK LIMITED TO PATCH/

REPAIR AS NECESSITATED BY

REMOVAL AND REPLACEMENT

OF SUITE PERIMETER WALL

AND UTILITY CONNECTIONS

ASSOCIATED WITH MEP SCOPE

OF WORK

GENERAL NOTES

1. PROTECT EXTERIOR WINDOW TREATMENTS FROM DUST AND DEBRIS DURING

DEMOLITION AND CONSTRUCTION.

2. PROTECT ALL PERIMETER FLOOR MOUNTED FAN-COIL UNITS FROM DUST AND

DEBRIS DURING DEMOLITION, AND CONSTRUCTION.

3. PROTECT ARCHITECTURAL COLUMN CLADDING ON ALL EXTERIOR PERIMETER

COLUMNS FROM DUST, DEBRIS, AND DAMAGE DURING DEMOLITION, AND

CONSTRUCTION.

4. REFER TO THE MEP DISCIPLINE DRAWINGS FOR EXTENT OF MEP SYSTEM DEMOLITION.

5. PROTECT EXISTING WALLS AND FINISHES IN THE ADJACENT NO WORK AREA THAT

INTERFACE WITH THE AREA OF WORK.

6. ASBESTOS CONTAINING MATERIAL:

ASBESTOS WAS CONFIRMED PRESENT IN THE MASTIC BENEATH THE CARPET IN THE

WEST OFFICE AREA (APPROXIMATELY 1300 SF) - SEE HATCHED AREA ON ABOVE PLAN.

REFER TO ABATEMENT DRAWINGS AND PRE-ALTERATION SURVEY IN THE APPENDIX OF

THE PROJECT SPECIFICATIONS

7. ALL EXISTING FURNITURE REMAINING IN THE SUITE AT START OF CONSTRUCTION IS TO

BE REMOVED AND RECYCLED WHERE POSSIBLE OR ELSE DISPOSED OF

33RD FLOOR DEMOLITION PHOTOS

2 3

EXISTING SERVICE

WINDOW TO BE REMOVED

EXISTING COLUMN

EXISTING PANTRY

EXISTING ROOM

DIVIDER

6 87

EXISTING ICE MAKER -

SALVAGE FOR

REINSTALLATION

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

D133

JCK 33RD FLOOR - DEMOLITION PLAN

BS/TS LW/CY

1/8" = 1'-0"

LEVEL 33 - DEMOLITION PLAN

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

33RD FLOOR DEMO PLAN KEYNOTE LEGEND

KEY NOTE

NUMBER TEXT

1 EXISTING COLUMN ENCLOSURES TO REMAIN - PATCH TO MATCH ADJACENT FINISH AS EQUIRED WHERE ADJACENT CONDITIONS

ARE REMOVED - REMOVE EXISTING BASE - TYPICAL THROUGOUT

2 REMOVE EXISTING RESILIENT BASE, CARPET, UNDERLAYMENT, AND ADHESIVE DOWN TO SLAB IN PREPARATION FOR NEW FLOOR FINISH - TYPICAL THROUGHOUT ENTIRE SUITE AND BETWEEN FAN COIL UNIT AND CURTAIN WALL

3 REMOVE EXISTING CORRIDOR WALL SYSTEM AND BASE

4 REMOVE EXISTING DOORS, FRAMES AND HARDWARE (INCLUDING SIDELITES WHERE APPLICABLE) THROUGHOUT ENTIRE SUITE

EXCEPT WHERE SPECIFICALLY NOTED TO REMAIN

5 REMOVE EXISTING GYP BOARD PARTITIONS FOR ENTIRE HEIGHT - TYPICAL THROUGHOUT ENTIRE SUITE - AS INDICATED BY

DASHED LINES (REFER TO LEGEND)

6 REMOVE DEMOUNTABLE PARTITION SYSTEM, INCLUDING DOORS, ASSOCIATED HARDWARE, AND SIDELITES

7 REMOVE EXISTING SERVICE WINDOW AND COUNTERTOP AT HIGH DENSITY FILE STORAGE SYSTEM (REFER TO PHOTO #1)

8 REMOVE EXISTING HIGH DENSITY FILE (HDF) STORAGE SYSTEM. ALONG WITH HDF TRACKS AND RAISED FLOOR ASSEMBLY (REFER TO PHOTO #2) PATCH REPAIR FLOOR SLAB AS REQUIRED IN PREPARATION FOR NEW FLOOR FINISH

9 PROTECT EXISTING COLUMNS AND ARCHITECTURAL CLADDING FROM DUST AND DEBRIS DURING DEMOLITION, AND CONSTRUCTION. DEMOLISH AND REPLACE EXISTING VINYL BASE AT ALL COLUMNS. REPAIR, REPAINT, AND REFINISH COLUMN

CLADDING DAMAGED BY DEMOLITION AND CONSTRUCTION, TYP. (REFER TO PHOTO #3)

10 EXISTING PANTRY CASEWORK, REFRIGERATOR, AND PLUMBING FIXTURES TO BE REMOVED (REFER TO PLUMBING DRAWINGS) - NOTE, EXISTING ICE MACHINE TO BE SALVAGED FOR RE-INSTALLATION - SEE PHOTOS 4 AND 6

11 PROTECT EXISTING ROOM DIVIDER AT EXISTING PANTRY. EXISTING ROOM DIVIDER TO REMAIN AND BE REUSED (SEE PHOTO #5)

12 REMOVE AND SALVAGE EXISTING LOCKERS - TURN OVER TO GSA PROPERTY MANAGEMENT - (REFER TO PHOTO #8)

13 REMOVE EXISTING WALL MOUNTED CASEWORK

(SEE PHOTO #7)

P

U

PD

N

FACP

FACP

ABCDEFGHJ

28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"

A401

K

CORRIDOR CEILING:

DESIGN INTENT IS TO RETAIN EXISTING CORRIDOR

CEILING AND LIGHTING (LIGHT GRAY AREA) - SOME

REPAIR/REPLACEMENT MAY BE NECESSITATED BY

ADJACENT DEMOLITION SCOPE. CONTRACTOR IS

RESPONSIBLE FOR REPAIRING AND REPLACING

THE CEILING IN KIND AS REQUIRED.

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE REMOVED

LEGEND

EXISTING LIGHTING TO BE

REMOVED AND DISCARDED

EXISTING ACT CEILING TO BE

REMOVED AND DISCARDED

EXISTING AIR TERMINAL TO BE

REMOVED AND DISCARDED

EXISTING ACCESS HATCH TO

BE REMOVED AND DISCARDED

AREAS OUT OF GENERAL

ARCHITECTURAL SCOPE.

PUBLIC CORRIDOR - EXISTING

TO REMAIN - NO WORK

ANTICIPATED EXCEPT UTILITY

CONNECTIONS AS

REFERENCED ON MEP

DRAWINGS - REPAIR / REPLACE

AS REQUIRED

GENERAL NOTES

1. PROTECT EXTERIOR WINDOW TREATMENTS/ BLINDS TO REMAIN FROM DUST AND DEBRIS

DURING DEMOLITION AND CONSTRUCTION.

2. PROTECT ALL PERIMETER FLOOR MOUNTED FAN-COIL UNITS FROM DUST AND DEBRIS

DURING DEMOLITION, AND CONSTRUCTION.

3. PROTECT ARCHITECTURAL COLUMN CLADDING ON ALL COLUMNS FROM DUST, DEBRIS, AND

DAMAGE DURING DEMOLITION, AND CONSTRUCTION.

4. REFER TO THE MEP DISCIPLINE DRAWINGS FOR THE EXTENT OF THE MEP SYSTEM

DEMOLITION. NOTE THAT SOME M/E/FP SYSTEMS SHALL BE MAINTAINED TO KEEP THE SPACE

CODE-COMPLIANT.

5. REMOVE AND DISCARD ALL AIR TERMINALS FROM CEILING.

6. ASBESTOS CONTAINING MATERIAL:

ASBESTOS WAS CONFIRMED PRESENT IN EXISTING DUCT SEALANT (DARK GRAY SEAM

SEALANT) AT 31ST, 32ND AND 33RD FLOOR SPACES - REFER TO PRE-ALTERATION SURVEY

INCLUDED IN THE APPENDIX OF THE PROJECT SPECIFICATIONS. (NOTE THAT MATERIAL MAY

BE PRESENT IN AREAS NOT IDENTIFIED IN THE SURVEY AREA.

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

D231

JCK 31ST FLOOR - DEMOLITION REFLECTED

CEILING PLAN

BS/TS LW/CY

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

1/8" = 1'-0"

LEVEL 31 - DEMOLITION REFLECTED

CEILING PLAN

P

U

PD

N

ABCDEFGHJ

28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"

EXISTING LIGHTING TO BE

REMOVED AND SALVAGED

FOR REINSTALLATION -

REFER TO ELECTRICAL

DRAWINGS

EXISTING PAINTED BREAK

METAL CLOSURE TRIM TO

REMAIN - TYP. ALONG

EXTERIOR WALL

K

CORRIDOR CEILING:

DESIGN INTENT IS TO RETAIN EXISTING CORRIDOR

CEILING AND LIGHTING (LIGHT GRAY AREA) - SOME

REPAIR/REPLACEMENT MAY BE NECESSITATED BY

ADJACENT DEMOLITION SCOPE. CONTRACTOR IS

RESPONSIBLE FOR REPAIRING AND REPLACING

THE CEILING IN KIND AS REQUIRED.

EXISTING PANTRY CEILING TO REMAIN

GENERAL NOTES

1. PROTECT EXTERIOR WINDOW TREATMENTS/ BLINDS TO REMAIN FROM DUST AND DEBRIS

DURING DEMOLITION AND CONSTRUCTION.

2. PROTECT ALL PERIMETER FLOOR MOUNTED FAN-COIL UNITS FROM DUST AND DEBRIS

DURING DEMOLITION, AND CONSTRUCTION.

3. PROTECT ARCHITECTURAL COLUMN CLADDING ON ALL COLUMNS FROM DUST, DEBRIS, AND

DAMAGE DURING DEMOLITION, AND CONSTRUCTION.

4. REFER TO THE MEP DISCIPLINE DRAWINGS FOR THE EXTENT OF THE MEP SYSTEM

DEMOLITION. NOTE THAT SOME M/E/FP SYSTEMS SHALL BE MAINTAINED TO KEEP THE SPACE

CODE-COMPLIANT.

5. REMOVE AND DISCARD ALL AIR TERMINALS FROM CEILING.

6. ASBESTOS CONTAINING MATERIAL:

ASBESTOS WAS CONFIRMED PRESENT IN EXISTING DUCT SEALANT (DARK GRAY SEAM

SEALANT) AT 31ST, 32ND AND 33RD FLOOR SPACES - REFER TO PRE-ALTERATION SURVEY

INCLUDED IN THE APPENDIX OF THE PROJECT SPECIFICATIONS. (NOTE THAT MATERIAL MAY

BE PRESENT IN AREAS NOT IDENTIFIED IN THE SURVEY AREA.

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE REMOVED

LEGEND

EXISTING LIGHTING TO BE

REMOVED AND DISCARDED

EXISTING ACT CEILING TO BE

REMOVED AND DISCARDED

EXISTING AIR TERMINAL TO BE

REMOVED AND DISCARDED

EXISTING ACCESS HATCH TO

BE REMOVED AND DISCARDED

AREAS OUT OF GENERAL

ARCHITECTURAL SCOPE.

PUBLIC CORRIDOR - EXISTING

TO REMAIN - NO WORK

ANTICIPATED EXCEPT UTILITY

CONNECTIONS AS

REFERENCED ON MEP

DRAWINGS - REPAIR / REPLACE

AS REQUIRED

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

D233

JCK 33RD FLOOR - DEMOLITION REFLECTED

CEILING PLAN

BS/TS LW/CY

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

1/8" = 1'-0"

LEVEL 33 - DEMOLITION REFLECTED

CEILING PLAN

OGC PANTRY

31038

PRINT/COPY/LIBRARY AREA

31070

COATS

31128

IDF

31034

OGC OFFICE

31042

OGC OFFICE

31046

OGC OFFICE

31050

OGC OFFICE

31052

OGC OFFICE

31054

OGC OFFICE

31058

OGC OFFICE

31062

OGC OFFICE

31066

OGC OFFICE

31068

OGC OFFICE

31072

OGC OFFICE

31074

OGC OFFICE

31076

OGC OFFICE

31078

OGC OFFICE

31082

OGC OFFICE

31086

OGC OFFICE

31092

OGC OFFICE

31096

OGC OFFICE

31100

OGC OFFICE

31104

OGC OFFICE

31106

OGC OFFICE

31108

OGC OFFICE

31112

OGC OFFICE

31114

DEPUTY CHIEF

COUNSEL OFFICE

31118

OGC OFFICE

31040

OGC OFFICE

31044

OGC OFFICE

31048

OGC OFFICE

31056

OGC OFFICE

31060

OGC OFFICE

31064

OGC OFFICE

31080

OGC OFFICE

31084

OGC OFFICE

31090

OGC OFFICE

31094

OGC OFFICE

31098

OGC OFFICE

31102

OGC HUDDLE

31116

CHIEF COUNSEL

OFFICE

31120

28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"

31038

31048

31036

A4001

A400

31034

A131.1

Sim

31120

310A

A4002

31042 31046 31050 31052 31054 31058 31062 31066

31064310603105631044

31068 31072 31114 31118

311123110831106

3110231098

3110431100

31094

31092 31096

31080

3108631082310783107631074

CORRIDOR

31126

31122

OGC COPY/MAILING

ROOM

31036

CENTER PARTITION ON MULLION OR

COLUMN (TYP.)

UNLESS NOTED OTHERWISE

-SEE DETAIL 1/A-500

OGC OFFICE

31110

RECEPTION

31122

CORRIDOR

31124

31116

311103109031084

A401

31126

31040

FOLDING PANEL PARTITION B

A401

K

WALL MTD. MONITOR -

REFER TO AV DRAWINGS

GENERAL NOTES

1. REFER TO SHEET A131.1 FOR WALL LAYOUT AND WALL TYPE INFORMATION

2. PROVIDE BLOCKING IN WALLS AT WALL MOUNTED EQUIPMENT LOCATIONS -

REFER TO MEP DRAWINGS.

3. ALL COAT CLOSETS TO RECEIVE HANGING ROD AND SHELF.

4. PROTECT EXTERIOR WINDOW TREATMENTS/ BLINDS TO REMAIN FREE FROM

DUST AND DEBRIS DURING DEMOLITION AND CONSTRUCTION.

5. PROTECT PERIMETER INDUCTION UNITS DURING CONSTRUCTION.

6. PATCH WALLS AS REQUIRED FOR REMOVAL/RELOCATION OF EXISTING POWER

AND DATA SYSTEMS. SEE ELECTRICAL DRAWINGS FOR LOCATIONS.

7. PATCH WALLS AS REQUIRED FOR INSTALLATION OF NEW POWER AND DATA

SYSTEMS. SEE ELECTRICAL DRAWINGS FOR LOCATIONS.

8. PREPARE EXISTING FLOORS TO RECEIVE NEW FLOOR FINISHES PER

SPECIFICATIONS AND FINISH MATERIAL MANUFACTURERS REQUIREMENTS.

9. WHERE EXISTING STRUCTURAL STEEL FIREPROOFING IS DAMAGED BY WORK,

PATCH AS REQUIRED TO RESTORE 2 HOUR FIRE RATING.

10. FLOOR LEVELING REQUIREMENTS:

GENERAL:

ADD SELF LEVELING UNDERLAYMENT AS REQUIRED TO PROVIDE LOCALIZED

LEVELING AND REPAIRS TO CONDITION IN ACCORDANCE WITH FLOORING

MATERIAL MANUFACTURER REQUIREMENTS.

AT FOLDING WALLS:

PROVIDE LOCALIZED LEVELING ALONG PATH OF FOLDING TO BRING FLOOR

INTO COMPLIANCE WITH MANUFACTURER'S FLOOR LEVEL REQUIREMENTS.

LEGEND

NEW GYP BOARD

PARTITION

EXISTING PARTITION

TO REMAIN

AREAS OUT OF GENERAL

ARCHITECTURAL SCOPE.

PUBLIC CORRIDOR - EXISTING

TO REMAIN - NO WORK

ANTICIPATED EXCEPT UTILITY

CONNECTIONS AS

REFERENCED ON MEP

DRAWINGS - REPAIR / REPLACE

AS REQUIRED

NEW DEMOUNTABLE PARTITION

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

A131

JCK 31ST FLOOR - FLOOR PLAN

BS/TS Checker

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

1/8" = 1'-0"

LEVEL 31 - FLOOR PLAN

OGC PANTRY

31038

PRINT/COPY/LIBRARY AREA

31070

COATS

31128

IDF

31034

OGC OFFICE

31042

OGC OFFICE

31046

OGC OFFICE

31050

OGC OFFICE

31052

OGC OFFICE

31054

OGC OFFICE

31058

OGC OFFICE

31062

OGC OFFICE

31066

OGC OFFICE

31068

OGC OFFICE

31072

OGC OFFICE

31074

OGC OFFICE

31076

OGC OFFICE

31078

OGC OFFICE

31082

OGC OFFICE

31086

OGC OFFICE

31092

OGC OFFICE

31096

OGC OFFICE

31100

OGC OFFICE

31104

OGC OFFICE

31106

OGC OFFICE

31108

OGC OFFICE

31112

OGC OFFICE

31114

DEPUTY CHIEF

COUNSEL OFFICE

31118

OGC OFFICE

31040

OGC OFFICE

31044

OGC OFFICE

31048

OGC OFFICE

31056

OGC OFFICE

31060

OGC OFFICE

31064

OGC OFFICE

31080

OGC OFFICE

31084

OGC OFFICE

31090

OGC OFFICE

31094

OGC OFFICE

31098 OGC OFFICE

31102

OGC HUDDLE

31116

CHIEF COUNSEL

OFFICE

31120

CORRIDOR

31126

OGC COPY/MAILING

ROOM

31036

OGC OFFICE

31110

RECEPTION

31122

CORRIDOR

31124

2' - 9 1/2"

4' - 0"

10' - 3 1/2" 3' - 3" 7' - 1" 3' - 6"

10' - 7" 2' - 1" 8' - 6"

14' - 5"

2' - 5"8' - 2"

7' - 9"

/2

ALIGN

ALIGN

ALIGNALIGN

ALIGN

/2

A131.1

Sim

CENTER PARTITION ON MULLION OR

COLUMN (TYP.)

UNLESS NOTED OTHERWISE

-SEE DETAIL 1/A-500

12' - 9"

K

ALIGN

A133.1

Sim

P1

P1

CONSTRUCT NEW TYPE P1 PARTITION IN SAME

LOCATION AS PREVIOUS DEMOLISHED

PARTITION -ALIGN NEW GYP. BOARD FINISH FACE

TO THAT OF EXISTING COLUMNS

P1

GC TO CONFIRM EXISTING

PARTITION IS BUILT TO UNDERSIDE

OF DECK - MODIFY/AUGMENT

CONSTRUCTION AS REQUIRED

7' - 1"

/2

H

CENTER NEW WALL ON

MULLION AT EXTERIOR

CURTAIN WALL U.N.O.,

TYP.

CENTER NEW WALL ON

COLUMN U.N.O., TYP.

EXISTING WALL TO REMAIN

CONTINUOUS

ACOUSTICAL SEALANT

AT EACH SIDE

EXISTING HVAC

INDUCTION UNIT TO

REMAIN

SCRIBE GYPSUM BOARD

TO HVAC INDUCTION

UNIT SPACER AND TAPE

JOINT

PARTITION TYPE PER

PLAN

CONTINUOUS BLACK

NEOPRENE TAPE SPACER -

ONE SIDED STICKY SIDE AT

CASING BEAD.

DO NOT FASTEN SPACER

TO STUD

DO NOT FASTEN STUD TO

MULLION

CONTINUOUS L CASING BEAD

AT EACH SIDE

EXISTING EXTERIOR

CURTAIN WALL SYSTEM

PARTITION TYPE PER PLAN

EDGE BEAD

ACOUSTICAL SEALANT BOTH SIDES -

PAINT TO MATCH WALL

EXISTING GYP. BOARD FINISH AT

COLUMN - PAINT

CL PARTITION AND MULLION

NEW ACOUSTIC INSULATION TO BE

ADDED INSIDE VOID BENEATH

CONVECTOR COVER IN LINE WITH

NEW PARTITIONS - TYP.

GENERAL NOTES

1. ALL GYP BOARD PARTITIONS TO BE TYPE P3 EXCEPT WHERE NOTED

OTHERWISE.

2. ALL DIMENSIONS ARE TO FINISH FACE UNLESS NOTED OTHERWISE.

3. DENOTES EXTENT OF TYPE P1 WALL CONSTRUCTION

4. P4 PARTITIONS WHERE BACK OF WALL IS NOT ACCESSIBLE

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

A131.1

JCK 31ST FLOOR - DIMENSION PLAN

BS/TS Checker

Description Date

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

1/8" = 1'-0"

LEVEL 31 - DIMENSION PLAN

1 1/2" = 1'-0"

TYPICAL PLAN DETAIL AT

CURTAINWALL AND COLUMN

RF-1BFP-1

TP-1

ABCDEFGHJ

OGC PANTRY

31038

OGC COPY/MAILING ROOM

31036

PRINT/COPY/LIBRARY AREA

31070

IDF

31034

OGC OFFICE

31042

OGC OFFICE

31046

OGC OFFICE

31050

OGC OFFICE

31052

OGC OFFICE

31054

OGC OFFICE

31058

OGC OFFICE

31062

OGC OFFICE

31066

OGC OFFICE

31068

OGC OFFICE

31072

OGC OFFICE

31074

OGC OFFICE

31076

OGC OFFICE

31078

OGC OFFICE

31082

OGC OFFICE

31086

OGC OFFICE

31092

OGC OFFICE

31096

OGC OFFICE

31100

OGC OFFICE

31104

OGC OFFICE

31106

OGC OFFICE

31108

OGC OFFICE

31112

OGC OFFICE

31114

DEPUTY CHIEF COUNSEL OFFICE

31118

OGC OFFICE

31040

OGC OFFICE

31044

OGC OFFICE

31048

OGC OFFICE

31056

OGC OFFICE

31060

OGC OFFICE

31064

OGC OFFICE

31080

OGC OFFICE

31084

OGC OFFICE

31090

OGC OFFICE

31094

OGC OFFICE

31098

OGC OFFICE

31102

OGC HUDDLE

31116

CHIEF COUNSEL OFFICE

31120

Department Legend

OGC

P1 - OGC

P1 - OGC

28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"

OGC OFFICE

31110

CORRIDOR

31126

CORRIDOR

31124

WS1

WS1

T#

C# C# C#

C#C#C#

C# C#

C#

C#T4C#

OF1

OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1OF1

OF1 OF1

OF1 OF1 OF1

OF1 OF1 OF1 OF1

OF1 OF1 OF1

OF1

S1 S1 S1 S1 S6 S6 S6 S6S6 S6 S6 S6

K

FURNITURE LEGEND

C# CHAIR TYPE "X" TO BE IDENTIFIED BY FURNITURE

DESIGNER

CX BENCH AT LOCKER ROOM

T1 CONFERENCE TABLE

T2 SMALL CONFERENCE TABLE

T3 CAFE TABLE

T4 RECEPTION GUEST TABLE

T5 FOLDING / NESTING TABLE ON CASTERS

T# TABLE TYPE "X"

WS1 6X8 WORK STATION W/ ADJUSTABLE HEIGHT DESK

WS2 6X6 WORK STATION W/ ADJUSTABLE HEIGHT DESK

BS1 BENCHING STATION (SINGLE)

BS2 BENCHING STATION ROW W/ CENTER SPINE

S1 LATERAL FILES W/ TOP FOR WORK SURFACE

S2 SERVING CREDENZA

S3 AV CREDENZA

S4 OPEN SHELVING - FREE STANDING

S5 WALL SHELVING - IT STORAGE

S6 LIBRARY STORAGE

S7 WARDROBE LOCKERS

S8 FIVE DRAWER FILE CABINET

S9 STORAGE CABINET

L1 LECTERN

OF1 OFFICE SETUP 1 - 6X8 ADJUSTABLE HEIGHT DESK W/

RETURN, WARDROBE, TASK CHAIR, GUEST CHAIR(S)

P1 - XXX MULTI-FUNCTION PRINTER - DEPT. DESIGNATION

P2 - XXX NETWORK DESKTOP PRINTER - DEPT. DESIGNATION

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

AF131

JCK 31ST FLOOR - FURNITURE PLAN (NIC)

BS/TS Checker

1/8" = 1'-0"

LEVEL 31 - FURNITURE PLAN (NIC)

0' 4' 8' 16' 32'

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

PLAN PROVIDED FOR FURNITURE COORDINATION PURPOSES WITH UTILITIES, SEE SEPARATE GSA FURNITURE DRAWINGS AND SPECIFICATIONS FOR FURNITURE SCOPE OF WORK

P

U

PD

N

ABCDEFGHJ

MDF / LAN

33048

EVIDENCE

33046

HEARING ROOM

33044C

PRETRIAL ROOM

33044A

SEQUESTER ROOM

33044B

OCR OFFICE

33054

OCR OFFICE

33056

OCR OFFICE

33058

OCR OFFICE

33064

OCR OFFICE

33066

OCR OFFICE

33068

OCR OFFICE

33070

OCR OFFICE

33072

CMS UNION OFFICE

33074

OGC OFFICE /

HUDDLE

33040

OGC OFFICE /

HUDDLE

33038

CMS HUDDLE

33078

COPY

33080

MAIL

33082

HSPD - 12

33092

SUPPLIES STORAGE

33094

OUTREACH

STORAGE

33096

CMS OFFICE

33102

CMS OFFICE

33100

CMS OFFICE

33098

CONFERENCE ROOM

33090

CMS OFFICE

33088

CMS OFFICE

33086

CMS OFFICE

33084

EXECUTIVE CONF. ROOM

33106

CMS RA OFFICE

33108

CMS OFFICE

33112

CMS HUDDLE

33110

CMS OFFICE

33008

CMS HUDDLE

33010

CMS OFFICE

33006

CMS OFFICE

33004

CMS OFFICE

33002

COLLABORATION AREA

33014

BREAK

33016

PANTRY

33005

SUPPLIES / LOCKER

STORAGE

33026

CMS HUDDLE

33028

CMS OFFICE

33024

CMS OFFICE

33020

CMS OFFICE

33022

CMS FOCUS

33032

CMS FOCUS

33034

MULTIPURPOSE ROOM

33007

IT STORAGE /

WORKSHOP

33001

SERVER

33003

CONF. FURNITURE

STORAGE

33007A

OPEN OFFICE

33030

CORRIDOR

330C

OPEN OFFICE

33018

CORRIDOR

330B

OPEN OFFICE

33012

OPEN OFFICE

33114

CORRIDOR

330A

OPEN OFFICE

33036

CORRIDOR

330D

OPEN OFFICE

33076

CORRIDOR

330F

OPEN OFFICE

33104

CORRIDOR

330G

CORRIDOR

330E

3' - 0"

ALIGN

28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"

33028

33024 33014.2

33007.2

33007A

33058

33048

330E

33044C

33030

33001.1

33001.2

33003

CMS FOCUS

33118

CMS FOCUS

33116

ALIGN FACE

OF STUD WITH

COLUMN.

OGC OFFICE /

HUDDLE

33042

A400

A400 5

A400

33032

33034

A131.1

A400 8

A400

OCR MEETING ROOM

33050

3300433006

AV CLOSET

33007B

33014.1

33026

3302033022

33056

33054

33080 33082 33092

33094 33096

33044B

33044A

33116

33118

33036B

COATS

33036B 33000

33104

330F

A401

33074

CORRIDOR

33076A

33046

33050

33016.2

330H

A400

11A400

A402

FOLDING PANEL

PARTITION D

FOLDING

PANEL

PARTITION E

A500

TYP.

FOLDING PANEL

PARTITION C

COATS

33093

33093

CORRIDOR

330H

CORRIDOR

330J

A400

A400

33075

CLOSET

33075

A40015

33076

33007.1

33007B

A401

A402

K

33008

33010

33064 33066 33068 33070 33072 33084 33086 33088 33098 33100 33102

33112

33106 33108

33090.1 33090.2

33016.1

33087 33089 33090

33078

33110

A603

CORRIDOR

33000

CONFIRMATION OF EXISTING WALL

CONSTRUCTION REQUIRED -

SOME MODIFICATION MAY BE

REQUIRED TO ACCOMMODATE

LATERAL ROUTING OF NEW

INSULATED PLUMBING PIPING

OCR COPY/FILE/SHRED

33052

OCR OFFICE

33060

OCR OFFICE

33062

A500

3306233060

33052

31127

33002

LEGEND

NEW GYP BOARD

PARTITION

EXISTING PARTITION

TO REMAIN

AREAS OUT OF GENERAL

ARCHITECTURAL SCOPE.

PUBLIC CORRIDOR - EXISTING

TO REMAIN - NO WORK

ANTICIPATED EXCEPT UTILITY

CONNECTIONS AS

REFERENCED ON MEP

DRAWINGS - REPAIR / REPLACE

AS REQUIRED

NEW DEMOUNTABLE PARTITION

GENERAL NOTES

1. REFER TO SHEET A131.1 FOR WALL LAYOUT AND WALL TYPE INFORMATION

2. PROVIDE BLOCKING IN WALLS AT WALL MOUNTED EQUIPMENT LOCATIONS -

REFER TO MEP DRAWINGS.

3. ALL COAT CLOSETS TO RECEIVE HANGING ROD AND SHELF.

4. PROTECT EXTERIOR WINDOW TREATMENTS/ BLINDS TO REMAIN FREE FROM

DUST AND DEBRIS DURING DEMOLITION AND CONSTRUCTION.

5. PROTECT PERIMETER INDUCTION UNITS DURING CONSTRUCTION.

6. PATCH WALLS AS REQUIRED FOR REMOVAL/RELOCATION OF EXISTING POWER

AND DATA SYSTEMS. SEE ELECTRICAL DRAWINGS FOR LOCATIONS.

7. PATCH WALLS AS REQUIRED FOR INSTALLATION OF NEW POWER AND DATA

SYSTEMS. SEE ELECTRICAL DRAWINGS FOR LOCATIONS.

8. PREPARE EXISTING FLOORS TO RECEIVE NEW FLOOR FINISHES PER

SPECIFICATIONS AND FINISH MATERIAL MANUFACTURERS REQUIREMENTS.

9. WHERE EXISTING STRUCTURAL STEEL FIREPROOFING IS DAMAGED BY WORK,

PATCH AS REQUIRED TO RESTORE 2 HOUR FIRE RATING.

10. FLOOR LEVELING REQUIREMENTS:

GENERAL:

ADD SELF LEVELING UNDERLAYMENT AS REQUIRED TO PROVIDE LOCALIZED

LEVELING AND REPAIRS TO CONDITION IN ACCORDANCE WITH FLOORING

MATERIAL MANUFACTURER REQUIREMENTS.

AT FOLDING WALLS:

PROVIDE LOCALIZED LEVELING ALONG PATH OF FOLDING TO BRING FLOOR

INTO COMPLIANCE WITH MANUFACTURER'S FLOOR LEVEL REQUIREMENTS.

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

A133

JCK 33RD FLOOR - FLOOR PLAN

BS/TS Checker

Description Date

50% DESIGN DEVELOPMENT 3/3/22

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

1/8" = 1'-0"

LEVEL 33 - FLOOR PLAN

P

U

PD

N

B F

P -1

BFP-1

ABCDEFGHJ

MDF / LAN

33048

EVIDENCE

33046

HEARING ROOM

33044C

PRETRIAL ROOM

33044A

SEQUESTER ROOM

33044B

OCR OFFICE

33054

OCR OFFICE

33056

OCR OFFICE

33058

OCR OFFICE

33064

OCR OFFICE

33066

OCR OFFICE

33068

OCR OFFICE

33070

OCR OFFICE

33072

CMS UNION OFFICE

33074

OGC OFFICE /

HUDDLE

33040

OGC OFFICE /

HUDDLE

33038

CMS HUDDLE

33078

COPY

33080

MAIL

33082

HSPD - 12

33092

SUPPLIES STORAGE

33094

OUTREACH

STORAGE

33096

CMS OFFICE

33102

CMS OFFICE

33100

CMS OFFICE

33098

CONFERENCE ROOM

33090

CMS OFFICE

33088

CMS OFFICE

33086

CMS OFFICE

33084

EXECUTIVE CONF. ROOM

33106

CMS RA OFFICE

33108

CMS OFFICE

33112

CMS HUDDLE

33110

CMS OFFICE

33008

CMS HUDDLE

33010

CMS OFFICE

33006

CMS OFFICE

33004

CMS OFFICE

33002

COLLABORATION AREA

33014

BREAK

33016

PANTRY

33005

SUPPLIES / LOCKER

STORAGE

33026

CMS HUDDLE

33028

CMS OFFICE

33024

CMS OFFICE

33020

CMS OFFICE

33022

CMS FOCUS

33032

CMS FOCUS

33034

MULTIPURPOSE ROOM

33007

IT STORAGE /

WORKSHOP

33001

SERVER

33003

CONF. FURNITURE

STORAGE

33007A

OPEN OFFICE

33030

CORRIDOR

330C

OPEN OFFICE

33018

CORRIDOR

330B

OPEN OFFICE

33012

OPEN OFFICE

33114

CORRIDOR

330A

OPEN OFFICE

33036

CORRIDOR

330D

OPEN OFFICE

33076

CORRIDOR

330F

OPEN OFFICE

33104

CORRIDOR

330G

CORRIDOR

330E

CMS FOCUS

33118

CMS FOCUS

33116

OGC OFFICE /

HUDDLE

33042

OCR MEETING ROOM

33050

AV CLOSET

33007B

COATS

33036B

CORRIDOR

33076A

COATS

33093

CORRIDOR

330H

CORRIDOR

330J

EQ.EQ. 9' - 2"

3' - 3"

H O

L D

H O

L D

4' - 0" 13' - 4 1/2"

28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0" 28' - 0"

10' - 0"

4' - 6" 11' - 4"

4' - 0" 13' - 4 1/2"

/2

4' - 3 1/2"

/2

/2

6' - 6"

/2

14' - 0"

/2

3' - 3" 3' - 10 1/2"

1' - 6"

/2

9' - 6"

2' - 0" 8' - 11" 8' - 11"

3' - 10"

4' - 5" 7' - 4"

5' - 4"

/2

/2

13' - 1"

10' - 2 1/2"

ALIGN

ALIGN

ALIGN

ALIGNALIGN

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

PERIMETER PARTITIONS

CENTER ON MULLIONS OR

COLUMN LINES UNLESS

NOTED OTHERWISE

A133.1

A133.1

3' - 2"

ALIGN

ALIGN

A L

IG

N 5

" ALIGN ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

/2

ALIGN

A L

IG

N

ALIGN

ALIGN

ALIGN

A40015

1' - 1"

K

MONITOR MONITOR

M O

N

IT

O R

M O

N

IT

O R

M O

N

IT

O R

(2) MONITORS

TYP. TYP.

A131.1

Sim

WALL

MOUNTED

MONITORS -

REFER TO AV

DRAWINGS

TYP.

NOTE: SINK DRAIN PIPE

ROUTING WILL NOT CLEAR

EXISTING STRUCTURE AT 32ND

FLOOR AND WILL REQUIRE THAT

(1) NEW PENETRATION BE CUT

THROUGH EXISTING STEEL

FRAMING - ENGINEERING OF

THESE CONDITIONS IS NOT YET

COMPLETE

NOTE: SINK DRAIN PIPE ROUTING

WILL NOT CLEAR EXISTING

STRUCTURE AT 32ND FLOOR AND

WILL REQUIRE THAT (2) NEW

PENETRATIONS BE CUT THROUGH

EXISTING STEEL FRAMING -

ENGINEERING OF THESE

CONDITIONS IS NOT YET

COMPLETE

CENTER WALL ON COLUMN LINE

P1

P1

P1

P1

CL PARTITION AND

EXTERIOR MULLION

A

+ - 1' - 6 1/2"

CENTER NEW WALL ON

MULLION AT EXTERIOR

CURTAIN WALL U.N.O.,

TYP.

CONTINUOUS

ACOUSTICAL SEALANT

AT EACH SIDE

CONTINUOUS BLACK

NEOPRENE TAPE SPACER -

ONE SIDED STICKY SIDE AT

CASING BEAD.

DO NOT FASTEN SPACER

TO STUD

DO NOT FASTEN STUD TO

MULLION

CONTINUOUS L CASING BEAD

AT EACH SIDE

EXISTING EXTERIOR

CURTAIN WALL SYSTEM

CL PARTITION AND

EXTERIOR MULLION

PARTITION TYPE PER

PLAN

SCRIBE GYPSUM BOARD

TO HVAC INDUCTION

UNIT SPACER AND TAPE

JOINT

EXISTING HVAC

INDUCTION UNIT TO

REMAIN

GENERAL NOTES

1. ALL GYP BOARD PARTITIONS TO BE TYPE P3 EXCEPT WHERE NOTED

OTHERWISE.

2. ALL DIMENSIONS ARE TO FINISH FACE UNLESS NOTED OTHERWISE.

3. DENOTES EXTENT OF TYPE P1 WALL CONSTRUCTION

4. P4 PARTITIONS WHERE BACK OF WALL IS NOT ACCESSIBLE

GREAT LAKES REGION 5

SENSITIVE BUT UNCLASSIFIED

(SBU)

PROPERTY OF

THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy or return documents when no longer needed

DRAWING

NO.

DRAWING

TITLE

PUBLIC BUILDING SERVICE

OFFICE OF PROPERTY

DEVELOPMENT

REGION 5 CHICAGO, ILLINOIS

BLDG.

GENERAL SERVICES ADMINISTRATION

PROJECT

LOCATION

PCN

DRAWN

CONTRACT

CHECKED

FILE NUMBER: IN1710322_N1630165_ _1

ENGINEER

900 NORTH FRANKLIN STREET, SUITE 304

INTERACTIVE DESIGN

CHICAGO, IL 60610 - USA

Tel: 312-482-8866

ARCHITECT

ARUP

IL0236FC

CHICAGO, ILLINOIS

23456789101112131415

ABCDE

ENVIRONMENTAL

600 WEST VANBUREN STREET

CARNOW CONIBEAR & ASSOC.

CHICAGO, IL 60607 - USA

Tel: 312-762-2956

35 EAST WACKER DRIVE, SUITE 1800

CHICAGO, IL 60601 - USA

Tel: 312-849-5610

DEPARTMENT OF STATE CHICAGO

RELOCATION PROJECT - JCK

A133.1

JCK 33RD FLOOR - DIMENSION PLAN

BS/TS Checker

Description Date

100% DESIGN DEVELOPMENT 4/22/22

75% CONSTRUCTION DOCUMENTS 7/1/22

1/8" = 1'-0"

LEVEL 33 - DIMENSION PLAN

1 1/2" = 1'-0"

TYPICAL PLAN DETAIL AT INTERIOR

WALL AND DEMOUNTABLE PARTITON

1 1/2" = 1'-0"

TYPICAL PLAN DETAIL AT EXTERIOR

WALL AND DEMOUNTABLE PARTITION

7' - 7"

R. O. OF SLIDING DOOR ASSEMBLY TO BE VERIFIED BY DEMOUNTABLE PARTITION MANUFACTURER

P

U

PD

N

ABCDEFGHJ

RECEPTION

MDF / LAN

33048

EVIDENCE

33046

HEARING ROOM

33044C

PRETRIAL ROOM

33044A

SEQUESTER ROOM

33044B

OCR MEETING ROOM

33050

OCR OFFICE

33054

OCR OFFICE

33056

OCR OFFICE

33058

OCR OFFICE

33068

OCR OFFICE

33070

OCR OFFICE

33072

CMS UNION OFFICE

33074

OGC OFFICE / HUDDLE

33040

OGC OFFICE / HUDDLE

33038

CMS HUDDLE

33078

COPY

33080

MAIL

33082

HSPD - 12

33092

SUPPLIES STORAGE

33094

OUTREACH STORAGE

33096

CMS OFFICE

33102

CMS OFFICE

33100

CMS OFFICE

33098

CONFERENCE ROOM

33090

CMS OFFICE

33088

CMS OFFICE

33086

CMS OFFICE

33084

EXECUTIVE CONF. ROOM

33106

CMS RA OFFICE

33108

CMS HUDDLE

33110

CMS OFFICE

33008CMS HUDDLE

33010

CMS OFFICE

33006

CMS OFFICE

33004

CMS OFFICE

33002

COLLABORATION AREA

33014

BREAK

33016

PANTRY

33005

SUPPLIES / LOCKER STORAGE

33026

CMS HUDDLE

33028

CMS OFFICE

33024

CMS OFFICE

33020

CMS OFFICE

33022

CMS…