472_22426 - CTS Full Set Drawings_Stamped_Part6.pdf
PDF 5 MB Posted
- Attached to
- 472/22426. CTS; CMCF - Various Security Upgrades
- Solicitation number
- RFQ 171 240000000205 2
- Issued by
- Gogebic County, Sterling Heights City, Michigan
About this file
This is a construction design document set consisting of 50% Construction Document (CD) review drawings prepared by the State of Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division for the Central Michigan Correctional Facility located in St. Louis, Michigan. The project, titled "Various Security Upgrades" at 320 Hubbard, involves the design and installation of comprehensive security infrastructure upgrades including access control systems, video surveillance cameras, and communication equipment across multiple buildings. The drawings specify the installation of Hydra Gateway systems at three locations (West Admin Building, East Admin Building), multiple access points with designations such as AP G1.1 through AP G3.2, and numerous security devices distributed across 53 identified locations (H1 through H53). The design incorporates equipment from manufacturers including Genetec for access control modules and software, Altronix for power supplies and controllers, Aiphone for intercom systems, and Hanwha for security cameras. The drawings are dated 08-22-23 for the 50% CD review phase, with 90% drawings projected for 11/14/2023 and final 100% drawings scheduled for 1/19/2024, indicating the document was released for bid on 1/19/24.
The technical specifications detail equipment schedules, cable requirements, and installation standards for all security components. Communication infrastructure includes CAT-6 UTP cables in pink for PACS communications, fiber optic cable stowage rings, and patch panel installations within communication room racks. Access control components encompass Genetec Signo card readers, door control modules, intercom base stations, and battery backup systems with Altronix power distribution equipment. Video security specifications include both 360-degree fisheye cameras (Hanwha XNF-9010RV, 12-megapixel) and indoor short-distance cameras (Hanwha QNV-6082R1, 2-megapixel) with provisions for recessed mounts in drop ceilings and weatherproof exterior installations. All installations require compliance with specific cable labeling protocols, conduit routing through EMT-type raceway, mounting heights at approximately 6 feet above finished floor, and integration with existing Genetec network video recorders and Ethernet switches. The design documentation references multiple drawing sheets (SE-100 through SE-107 and TC101, TC301, TC501, TC701) detailing security panel layouts, raceway specifications, and equipment connectivity codes, with all work coordinated among electrical, communications, and security contractors.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M a t r ix
08-22-23 50% CD REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
S t r a u b
P e t t i t t Y a s t e
0 N
. C ro ok s R oa d, Su ite
Cl aw so n, Mi ch iga n 4
8 -
8 -
SE-100
11/14/2023
WP
90% Drawings
1/19/2024
100% Drawings
HS20E DOOR SENSORH#
AP G3.1
GateW2
ACCESS POINT
GATE WAY ANTENNA & HEADNED GEAR
LEGEND
HYDRA SITE
PLAN
SE-104
A
B
C
D E
F
G
H
J
K
L
M N P
Q
FS
R
E. AdminW. Admin
H1 H2
H3
H4
H5 H6
H7 H8
H9
H10
H11 H12
H13 H14
H15
H16
H18 H17
H20H19
H21
H22
H24 H23
H26 H25
H29
H28
H27
H30
H31H32
H33
H34
H35 H36 H39 H40
H42
H41H38
H37
H43 H44
H45
H46
H48 H47
H49
H50
AP G1.2
AP G1.1
AP G1.3
GateW1 GateW2
AP G2.1
AP G2.2
AP G3.1
AP G3.2
GateW3
H51
H52
H53
WEST ADMIN BUILDING
Hydra Gateway Board/Lightning & Surge
Protection #1
Hydra Relay Board
Backup Battery
UltraLinks
Network Switch
AP Gateway 1.1
AP Gateway 1.2
AP Gateway 1.3
UPS
110AC Circuit From Nearest Emergency Circuit
LOCATE GEAR IN
ELECTRONICS RM
M a t r ix
08-22-23 50% CD REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
S t r a u b
P e t t i t t Y a s t e
0 N
. C ro ok s R oa d, Su ite
Cl aw so n, Mi ch iga n 4
8 -
8 -
SE-100
11/14/2023
WP
90% Drawings
HYDRA GW 1
SE-105
1/19/2024
100% Drawings
M a t r ix
08-22-23 50% CD REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
S t r a u b
P e t t i t t Y a s t e
0 N
. C ro ok s R oa d, Su ite
Cl aw so n, Mi ch iga n 4
8 -
8 -
SE-100
11/14/2023
WP
90% Drawings
EAST ADMIN BUILDING
Hydra Gateway Board/Lightning & Surge
Protection #2
Hydra Relay Board
Backup Battery
UltraLinks
Network Switch
UPS
110AC Circuit From Nearest Emergency Circuit
LOCATE GEAR IN
ELECTRONICS RM
AP Gateway 2.1
AP Gateway 2.2
HYDRA GW 2
SE-106
EAST ADMIN BUILDING
Hydra Gateway Board/Lightning & Surge
Protection #3
Hydra Relay Board
Backup Battery
UltraLinks
Network Switch
UPS
110AC Circuit From Nearest Emergency Circuit
LOCATE GEAR IN
ELECTRONICS RM
M a t r ix
08-22-23 50% CD REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
S t r a u b
P e t t i t t Y a s t e
0 N
. C ro ok s R oa d, Su ite
Cl aw so n, Mi ch iga n 4
8 -
8 -
SE-100
11/14/2023
WP
90% Drawings
AP Gateway 3.1
AP Gateway 3.2
HYDRA GW 3
SE-107
ACCESS CONTROL EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
TC501
TYPICAL ACCESS CONTROL
CABLE LABELING
TC501
TYPICAL SECURITY WALLFIELD
SECURITY SYMBOL LEGEND
SYMBOL DESCRIPTION
ABBREVIATIONS
ABBREV. DESCRIPTION ABBREV. DESCRIPTION
TR101
TYPICAL CONDUIT AND SECURE BACKBOX
INSTALLED BY COMM CONTRACTOR
TC501
CONNECTIVITY CODE
COMMUNICATION EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
CABLE SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
CAMERA EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO. DROP CEILING HARD
CEILING/WALL
BUILDING
EXTERIOR
BUILDING
EXTERIOR
CORNER
POLE MOUNT
TC501
CENTRAL MICHIGAN
CAMERA ONE-LINE-TRANSPORTATION
TC501
CONNECTIVITY CODE TC501
CENTRAL MICHIGAN
ACCESS CONTROL
DETAILS
C om m te ch
D es ig n
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
B
EL
D
IN
G R
D . N
E, S
U
IT
E B
R O
C
KF
O R
D , M
IC
H
IG
AN
W
W W
.C O
M M
TE
C
H D
ES
IG
N .C
O M
M a t r ix
AutoCAD SHX Text
ACCESS CONTROL SYSTEM, SOFTWARE AND SERVER. PROVIDE NEW SERVER
AutoCAD SHX Text
GENETEC
AutoCAD SHX Text
GSC-SY-S
AutoCAD SHX Text
ACCESS CONTROL ENCLOSURE. BACKPLATE AND LOCKABLE PANEL
AutoCAD SHX Text
ALTRONIX
AutoCAD SHX Text
TROVE 1/2/3
AutoCAD SHX Text POWER SUPPLY FOR ACCESS CONTROL EQUIPMENT. EQUIP WITH ETHERNET CONNECTIVITY MODULE
AutoCAD SHX Text
ALTRONIX
AutoCAD SHX Text
E-FLOW SERIES W/ LINQ2 ENET MOD.
AutoCAD SHX Text POWER DISTRIBUTION BOARD AND VOLTAGE REGULATOR. POWERS OTHER BOARDS IN THE ACCESS CTRL PANEL
AutoCAD SHX Text
ALTRONIX
AutoCAD SHX Text
PDS8 SERIES WITH VR6 REGULATOR
AutoCAD SHX Text
ACCESS POWER CONTROLLER
AutoCAD SHX Text
ALTRONIX
AutoCAD SHX Text
ACMS8 OR EQUAL
AutoCAD SHX Text
DOOR ACCESS CONTROL MODULE. IP ATTACHED. QTY AS REQUIRED
AutoCAD SHX Text
GENETEC
AutoCAD SHX Text
SY-LP4502
AutoCAD SHX Text
DOOR ACCESS CONTROL MODULE. RS-485 ATTACHED. QTY AS REQUIRED
AutoCAD SHX Text
GENETEC
AutoCAD SHX Text
SY-MR52
AutoCAD SHX Text
ACCESS CONTROL SYSTEM CONTROLLER/APPLIANCE
AutoCAD SHX Text
GENETEC
AutoCAD SHX Text
SY-CLOUDLINK
AutoCAD SHX Text
CARD READER. MOUNT ON A SINGLE GANG BOX
AutoCAD SHX Text
GENETEC
AutoCAD SHX Text
SIGNO 40-PIV
AutoCAD SHX Text
BATTERY FOR ACCESS CONTROL PANEL
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text
INTERCOM BASE STATION
AutoCAD SHX Text
AIPHONE
AutoCAD SHX Text
IX-MV7-HW-JP
AutoCAD SHX Text
IP PROGRAMMABLE RELAY
AutoCAD SHX Text
AIPHONE
AutoCAD SHX Text
IXW-MA
AutoCAD SHX Text INTERCOM -SURFACE MOUNT. EQUIP WITH CUSTOM BACKBOX AND PUSHBUTTON BELOW. CUSTOM WIRE TO SUPPORT ADA APPROVED CALL BUTTON HEIGHT
AutoCAD SHX Text
AIPHONE /ALARM CONTROLS
AutoCAD SHX Text
IX-DVF
AutoCAD SHX Text
BADGE ENROLLMENT PC AND CAMERA
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text
CD
AutoCAD SHX Text
CC
AutoCAD SHX Text
CB
AutoCAD SHX Text
CA
AutoCAD SHX Text
CE
AutoCAD SHX Text
CF
AutoCAD SHX Text
CG
AutoCAD SHX Text
CH
AutoCAD SHX Text
CJ
AutoCAD SHX Text
CL
AutoCAD SHX Text NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. 2. WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND BE WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND BE SELF-LAMINATING. 3. AT THE PANEL THE CABLE SHALL BE LABELED AS IT CONNECTS TO THE AT THE PANEL THE CABLE SHALL BE LABELED AS IT CONNECTS TO THE PANEL. LABEL INDIVIDUAL SHEATHED CABLES IN A MULTI-SERVICE CABLE. 4. AT THE DOOR INSTALL THE LABEL AT THE DEVICE WHERE IT IS AT THE DOOR INSTALL THE LABEL AT THE DEVICE WHERE IT IS CONNECTED.
AutoCAD SHX Text AD02 = DOOR NUMBER AS SHOWN ON DRAWINGS A = COMM ROOM WHERE PANEL RESIDES LR = TWO LETTER DESIGNATION FOR DEVICE THAT THE CABLE CONNECTS TO.
AutoCAD SHX Text 4'x8'x3/4" PLYWOOD CUT TO FIT FIELD CONDITIONS
AutoCAD SHX Text
CABLES FOR DOOR SECURITY DEVICES
AutoCAD SHX Text
SECURITY PANEL BY SECURITY CONTRACTOR QTY AS REQ'D
AutoCAD SHX Text
WALLFIELD
AutoCAD SHX Text
ACCESS CONTROL DEVICES
AutoCAD SHX Text
ENLARGED VIEW OF TYPICAL SECURITY PANEL
AutoCAD SHX Text
AD02-A-LR
AutoCAD SHX Text
DOOR CTRL BOARD
AutoCAD SHX Text
INPUT/OUTPUT BOARD
AutoCAD SHX Text
LABELING AT THE DOOR OR REMOTE END
AutoCAD SHX Text
DOOR NUMBER AD02
AutoCAD SHX Text
AD02-A-DC
AutoCAD SHX Text
"LR" WRAP-AROUND LABEL FOR LATCH RETACTION
AutoCAD SHX Text
"DC" WRAP-AROUND LABEL FOR DOOR CONTACT
AutoCAD SHX Text
"CR" WRAP-AROUND LABEL FOR CARD READERS
AutoCAD SHX Text
"DC" WRAP-AROUND LABEL FOR DOOR CONTACT
AutoCAD SHX Text
AD02-A-DC
AutoCAD SHX Text
AD02-A-CR
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
6" CABLE LADDER
AutoCAD SHX Text SECURITY PANEL WALLFIELD NOTES: 1. PLYWOOD SHALL BE INSTALLED ON THE WALL BEHIND THE PLYWOOD SHALL BE INSTALLED ON THE WALL BEHIND THE PANELS AND RACEWAYS. 2. PLYWOOD SHALL BE FIREPROOF. A/C GRADE. C SIDE TO PLYWOOD SHALL BE FIREPROOF. A/C GRADE. C SIDE TO THE WALL. 3. INSTALL CABLE LADDER TYPE RACEWAY OR D-RINGS TO INSTALL CABLE LADDER TYPE RACEWAY OR D-RINGS TO ROUTE THE CABLES FROM THE CEILING TO THE PANELS. 4. MOUNT THE PANELS SO THAT THE TOP OF THE PANELS IS MOUNT THE PANELS SO THAT THE TOP OF THE PANELS IS ABOUT 6' AFF. 5. CONNECT SECURITY PANELS TO A GROUND BAR. PROVIDE CONNECT SECURITY PANELS TO A GROUND BAR. PROVIDE GROUND BAR ON THE WALLFIELD. 6. SEE TC503 AND TC502 FOR SPECIFIC PANEL, RACEWAY SEE TC503 AND TC502 FOR SPECIFIC PANEL, RACEWAY AND CABLING REQUIREMENTS
AutoCAD SHX Text PROVIDE 15' COIL OF CABLE ON METAL RING. LEVITON #4890-OFR or 48900-IFR
AutoCAD SHX Text KEYED NOTES: PROVIDE 15' OF CABLE PRIOR TO TERMINATION IN THE SECURITY PANEL. PROVIDE ON A FIBER OPTIC METAL RING. INSTALL ABOVE THE PANELS. PROVIDE ONE FOR EACH PANEL. GROUP PANEL CABLES ONTO PANEL SPECIFIC RING. EXTEND 120V POWER TO THE POWER SUPPLIES IN THE PANELS. PROVIDE PLUGS FOR POWER CONNECTIONS. SHALL BE A UPS AND GENERATOR BACKCED POWER CIRCUIT. PROVIDE SUPPORT FOR THE CABLES WITH CABLE LADDER OR OTHER RACEWAY.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PC
AutoCAD SHX Text THIS SYMBOL WITH A NUMBER INSIDE REFERS TO KEYNOTES. REFER TO NOTES ON THE SHEET OR WITHIN THE DETAIL FOR ADDITIONAL INFORMATION
AutoCAD SHX Text EQUIPMENT SCHEDULE. THIS SYMBOL WITH LETTERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.
AutoCAD SHX Text CABLE SCHEDULE. THIS SYMBOL WITH NUMBERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.
AutoCAD SHX Text ACCESS CONTROL SYMBOL. "XX" IS LETTERS. SEE DETAILS ON TC5XX SHEETS FOR EQUIPMENT, CABLING AND RACEWAY DETAILS.
AutoCAD SHX Text ACCESS CONTROL SYMBOL FOR EXISTING DEVICES. "XX" IS LETTERS. SEE DETAILS ON TC5XX SHEETS. LEAVE DEVICES AND CONNECT TO NEW SYSTEM OR LEAVE AS CONNECTED TO EXISTING SYSTEM. SEE NOTES AND DETAILS
AutoCAD SHX Text
DOOR NUMBER
AutoCAD SHX Text SECURITY PANEL. PROVIDE PANEL AND CONNECT AS SHOWN ON FLOORPLANS AND IN THE SPECIFICATIONS.
AutoCAD SHX Text COMPUTER. PROVIDE AND INSTALL A PC FOR THE SECURITY SYSTEM. SEE DETAILS ON TC5XX SHEETS AND SPECIFICATIONS FOR REQUIREMENTS
AutoCAD SHX Text SURFACE RACEWAY SYMBOL. CONTRACTOR TO INSTALL RACEWAY AND BACKBOX. SEE DETAILS FOR TYPE OF SURFACE RACEWAY AND SIZE OF BACKBOX.
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XX
AutoCAD SHX Text
XXX
AutoCAD SHX Text
XX
AutoCAD SHX Text
SEC.PNL
AutoCAD SHX Text 2G
AutoCAD SHX Text
TWO-GANG BOX - PROVIDED BY EC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
AC
AutoCAD SHX Text ABOVE COUNTER - INSTALL BACKBOX SAME HEIGHT AS OTHER ELECTRICAL OUTLETS ABOVE THE COUNTER.
AutoCAD SHX Text
PBO
AutoCAD SHX Text
PROVIDED BY OTHERS
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
PATCH CORD ORGANIZER - 1 UNIT HIGH
AutoCAD SHX Text
AFG
AutoCAD SHX Text
ABOVE FINISHED GROUND
AutoCAD SHX Text
PCO-2
AutoCAD SHX Text
PATCH CORD ORGANIZER - 2 UNITS HIGH
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AMERICAN WIRE GAUGE
AutoCAD SHX Text
PET
AutoCAD SHX Text
PROTECTED ENTRANCE TERMINAL
AutoCAD SHX Text
EMT
AutoCAD SHX Text
EMT TYPE CONDUIT
AutoCAD SHX Text
QTY
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
EC
AutoCAD SHX Text
ELECTRICAL CONTRACTOR
AutoCAD SHX Text
PROVIDE 120 VOLT OUTPUT FROM UPS PANEL IN COMM ROOM. ADMIN BUILDING ONLY.
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SINGLE-GANG BOX-ALUMINUM, ONE (3/4) OPENING, SINGLE-GANG BOX-ALUMINUM, ONE (3/4) OPENING, RED-DOT IHD3-2 IHD3-2 2 SQUARE LUG TYPE PLUGS FOR SPARE HOLES. FLAT BLADE SQUARE LUG TYPE PLUGS FOR SPARE HOLES. FLAT BLADE PLUGS ARE NOT ALLOWED 1 3/4" EMT TYPE CONDUIT CONTRACTOR 3/4" EMT TYPE CONDUIT CONTRACTOR CONTRACTOR 1 NYLON BUSHING NYLON BUSHING LOT TWO-HOLE CONDUIT STRAPS TWO-HOLE CONDUIT STRAPS LOT SECURITY SCREWS OR EXPANDABLE ANCHORS SECURITY SCREWS OR EXPANDABLE ANCHORS
AutoCAD SHX Text INDICATES THAT THE CABLES AT THIS LOCATION SHALL BE INSTALLED THROUGH NEW RACEWAY & BACKBOX THAT IS INSTALLED BY THE CONTRACTOR
AutoCAD SHX Text
18" A.F.F. OR AS NOTED ON FLOOR PLANS
AutoCAD SHX Text
COMMUNICATION CABLES
AutoCAD SHX Text
3/4" CONDUIT EMT TYPE
AutoCAD SHX Text
FACEPLATE
AutoCAD SHX Text
NYLON BUSHING
AutoCAD SHX Text
SQUARE LUG TYPE PLUG
AutoCAD SHX Text
1-GANG BACKBOX HUBBELL-BELL #5387-0
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 FACEPLATE HUBBELL IMF1OW FACEPLATE HUBBELL IMF1OW HUBBELL IMF1OW IMF1OW 2 CAT-6 CABLES-PINK MOHAWK M58282 CAT-6 CABLES-PINK MOHAWK M58282 MOHAWK M58282 M58282 2 CAT-6 JACK-PINK HUBBELL HXJ6PK CAT-6 JACK-PINK HUBBELL HXJ6PK HUBBELL HXJ6PK HXJ6PK 1 TWO-HOLE KEYSTONE HUBBELL IM2K1OW TWO-HOLE KEYSTONE HUBBELL IM2K1OW HUBBELL IM2K1OW IM2K1OW 2 1 UNIT BLANK HUBBELL IMB1OW1 UNIT BLANK HUBBELL IMB1OWHUBBELL IMB1OWIMB1OW
AutoCAD SHX Text
COMMUNICATION CABLES
AutoCAD SHX Text
WALL
AutoCAD SHX Text
FACEPLATE
AutoCAD SHX Text ±18"
AutoCAD SHX Text ±18"
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
SEE TRXXX DRAWINGS
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text
SINGLE RACK UNIT PATCH CORD ORGANIZER (PCO-1) WITH HINGED COVER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HS13C
AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR JACKS TO MATCH THE CABLE COLOR AND CABLE TYPE BEING TERMINATED. PROVIDE ONE MODULAR JACK FOR EACH CABLE BEING TERMINATED. SEE SPEC AND DRAWINGS FOR COLORS. EQUIP WITH REAR CABLE ORGANIZER
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PANEL:HPJ24 ORGANIZER:ECMBR3
AutoCAD SHX Text FIBER OPTIC CABLE STOWAGE RING. WALL MOUNTED. 12" OR 24". PROVIDE AND INSTALL TO SUPPORT BEND RADIUS REQUIREMENTS OF THE FIBER CABLE`
AutoCAD SHX Text
LEVITON
AutoCAD SHX Text
12" #48900-IFR / 24" #48900-OFR
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
CAT-6 UTP CABLES FOR PACS COMMUNICATIONS SHALL BE PINK IN COLOR
AutoCAD SHX Text
MOHAWK
AutoCAD SHX Text M58282
AutoCAD SHX Text
ACCESS CONTROL CABLE. COMBO CABLE FOR CR, DC, ES/EL ETC-PLENUM- PINK IN COLOR
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text INDIVIDUAL SECURITY DEVICE CABLE. PROVIDE AS PER MANUFACTURERS REQUIREMENTS. -PLENUM RATED. PINK IN COLOR
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CM
AutoCAD SHX Text
CN
AutoCAD SHX Text
CO
AutoCAD SHX Text
CP
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
CAT-6 CABLES FOR CAMERA & POE POWER
AutoCAD SHX Text
HARD CEILING SURFACE MOUNT STF-1913
AutoCAD SHX Text
SC
AutoCAD SHX Text
INTERIOR PENDANT MOUNT STF-1914
AutoCAD SHX Text
EMT COND.
AutoCAD SHX Text
SD
AutoCAD SHX Text
INDOOR AND OUTDOOR 360 FISHEYE SINGLE IMAGER 12 MEGAPIXEL
AutoCAD SHX Text
HANWHA
AutoCAD SHX Text
XNF-9010RV
AutoCAD SHX Text
SHD-1600FPW
AutoCAD SHX Text
SBP-167HMW, SBP-300WMW1 SBP-300NBW
AutoCAD SHX Text
SBP-300KMW1 SBP-300NBW
AutoCAD SHX Text
SBP-300PMW1 & SBP-300NBW
AutoCAD SHX Text
INDOOR SHORT DISTANCE CAMERA. 2MP. DROP OR HARD CEILING
AutoCAD SHX Text
HANWHA
AutoCAD SHX Text
QNV-6082R1
AutoCAD SHX Text
SHD-1408FPW
AutoCAD SHX Text
SC
AutoCAD SHX Text
SD
AutoCAD SHX Text KEYED VIDEO SECURITY NOTES: NEW CAMERA TO BE INSTALLED WITH NEW CABLE. CONTRACTOR TO AIM AND FOCUS CAMERA, AND MAKE SURE CAMERA & CABLE ARE FUNCTIONING PROPERLY.
AutoCAD SHX Text
AutoCAD SHX Text GENERAL VIDEO SECURITY NOTES: 1. CONTRACTOR SHALL PROVIDE ALL PATCH CABLES AT THE CAMERA AND CONTRACTOR SHALL PROVIDE ALL PATCH CABLES AT THE CAMERA AND AT THE COMM ROOM. MATCH COLOR OF CAMERA CABLE. 12" LONG AT SWITCH. 10' AT THE CAMERA. INSTALL NEW, THIN PATCH CABLES AS PER THE SPECIFICATIONS FOR ALL NEW AND REPLACED CAMERAS. 2. CONTRACTOR SHALL PROVIDE THE CORRECT CAMERA MOUNT BASED ON CONTRACTOR SHALL PROVIDE THE CORRECT CAMERA MOUNT BASED ON CAMERA LOCATION AND STRUCTURE AVAILABLE. PROVIDE RECESSED CAMERA MOUNTS IN DROP CEILINGS. REVIEW PLANS AND SITE PRIOR TO ORDERING. EACH EXTERIOR AND POLE MOUNTED CAMERA SHALL INCLUDE A HINGED BACKBOX FOR MOUNTING. 3. CAMERAS IN DROP CEILINGS SHALL BE RECESSED MOUNT. PROVIDE CAMERAS IN DROP CEILINGS SHALL BE RECESSED MOUNT. PROVIDE BACKPLATE OR T-BAR FOR SUPPORT FROM GRID, NOT JUST THE TILE. 4. CONTRACTOR SHALL PROVIDE AND INSTALL A CAMERA LICENSE FOR THE CONTRACTOR SHALL PROVIDE AND INSTALL A CAMERA LICENSE FOR THE CAMERAS BEING INSTALLED. APPLY TO EXISTING GENETEC SERVER. SETUP THE CAMERAS ON THE SYSTEM AND POPULATE THE EXISGTING VIEWING STATIONS WITH THE NEW CAMERAS. 5. WHERE THE CAMERA IS NOT INSTALLED INTO A DROP CEILING THE WHERE THE CAMERA IS NOT INSTALLED INTO A DROP CEILING THE CONTRACTOR SHALL PROVIDE A MOUNT AND HOUSING. PROVIDE WEATHERPROOF MOUNTS ON EXTERIOR CAMERAS. 6. ALL CAMERAS SHALL CONNECT TO THE IP NETWORK SWITCH IN THE ALL CAMERAS SHALL CONNECT TO THE IP NETWORK SWITCH IN THE COMMUNICATIONS ROOM OR CABINET. CONTRACTOR SHALL WORK WITH THE OWNER ON CONFIGURATION OF THE ETHERNET SWITCH. 7. NETWORK VIDEO RECORDER(S) (NVR) ARE EXISTING.NETWORK VIDEO RECORDER(S) (NVR) ARE EXISTING.
AutoCAD SHX Text
CAT-6 PATCH PANEL IN COMM ROOM RACK
AutoCAD SHX Text
EXISTING ETHERNET SWITCH
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE NEAR THE SECURITY CAMERA LOCATION. 2. SEE FLOORPLAN FOR LOCATION. SEE FLOORPLAN FOR LOCATION. 3. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR TYPESEE ARCHITECTURAL REFLECTED CEILING PLAN FOR TYPE
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6 CABLES-GREEN MOHAWK M58286 CAT-6 CABLES-GREEN MOHAWK M58286 MOHAWK M58286 M58286 1 CAT-6 JACK HUBBELL HXJ6GNCAT-6 JACK HUBBELL HXJ6GNHUBBELL HXJ6GNHXJ6GN
AutoCAD SHX Text
PENDANT CAMERA
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text
CAT-6 PATCH BY OTHERS
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
OPEN CEILING INSTALLATION
AutoCAD SHX Text
SECURITY CAMERA
AutoCAD SHX Text
ABOVE DROP CEILING INSTALLATION
AutoCAD SHX Text
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
CAT-6 SURFACE BOX
AutoCAD SHX Text
SURFACE MOUNTED CAMERA
AutoCAD SHX Text
CAT-6 SURFACE BOX
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
472/22426.CTS
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 1065-121
AutoCAD SHX Text sheet title
AutoCAD SHX Text
320 HUBBARD
AutoCAD SHX Text
VARIOUS SECURITY UPGRADES
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
CENTRAL MI CORRECTIONAL FACILITY
AutoCAD SHX Text
ST LOUIS, MICHIGAN
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E CESAR E. CHAVEZ AVE.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text 1/19/24
AutoCAD SHX Text
RELEASED FOR BID
File details come from the government source that posted it. Updated .