451524-1-38-01_11_SECURITY_S&S.pdf

PDF 3 MB Posted

Attached to
LAP - Regional Traffic Management Center Facility Construction Federal Funded Project FPID: D324-034B
Solicitation number
PD 24-25.086
Issued by
Escambia County, Florida

About this file

The document is a set of security system design and implementation drawings for the Florida-Alabama Transportation Planning Organization's (FL-AL TPO) new Regional Traffic Management Center Facility in Escambia County, Florida. The security plans, prepared by Halff Associates, Inc., detail a comprehensive security infrastructure including camera placement, access control systems, network integration, and door security configurations. The drawings cover multiple floor plans, camera schedules, installation details for cameras and access control devices, and technical specifications for integrating security technologies like the Alcatraz Rock biometric facial recognition system.

The security system design incorporates advanced technologies such as IP-based door controllers, Power over Ethernet (PoE) network switches, surge protection, and a hybrid cloud architecture for data management. The system includes 18 cameras with various mounting types and fields of view, both interior and exterior, strategically positioned to provide comprehensive coverage of the facility. The access control components feature electric locks, door contacts, and biometric readers positioned at key entry points, with specific installation guidelines for mounting heights and cable routing. The design also includes detailed network infrastructure planning, with considerations for Industrial IoT integration, surge protection, and cable management to ensure robust and reliable security system performance.

View the file

Other files

File Type Posted
LAP_-_Regional_Traffic_Management_Center_Facility_Construction_Federal_Funded_Project_FPID:_D324-034B.pdf PDF
FDOT_Form_575-060-13_v001_Non_Collusion.pdf PDF
Agreement.ModifiedA_LAPwith_FPID_no_pg_num.pdf PDF
Agreement.ModifiedA_LAPwith_FPID.docx DOCX document
451524-1-38-01_10_TELECOMMUNICATIONS_S&S_.pdf PDF
451524-1-38-01_00_ARCHITECTURE_S&S.pdf PDF
Trench_Safety_Act_(1)_(1).pdf PDF
2025DavidBaconWages.pdf PDF
U_-_Cert_Debarment_Susupension_Ineligibilty_w37503032_v001_(1)_(1).pdf PDF
LAP_Cert_of_Capacity_w52501046_v001_(1).pdf PDF
451524-1-38-01_04_STUCTURAL_S&S_.pdf PDF
451524-1-38-01_02_CIVIL_S&S_.pdf PDF
451524-1-38-01_03_LANDSCAPE_S&S_.pdf PDF
451524-1-38-01_08___ELECTRICAL_S&S.pdf PDF
Technical_Specifications_April_1_2025.pdf PDF
American_with_Disabilities_Act_Affidavit_(2).pdf PDF
DBE_Bid_Pkg_Info_w27503011_(1).pdf PDF
451524-1-38-01_07_MECHANICAL_S&S_.pdf PDF
Federal_Contract_Provisions_(CFR_200)_With_Sign_11-1-2024_(5)_(1).pdf PDF
Cert_Disclosure_of_Lobbying_Activities_w37503033_(2).pdf PDF
451524-1-38-01_09_ITS_S&S.pdf PDF
451524-1-38-01_05_FIRE_PROTECTION_S&S_.pdf PDF
451524-1-38-01_06_PLUMBING_S&S_.pdf PDF
451524-1-38-01_01__GEOTECHNICAL_S&S.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT OF

ALL POWER SOURCE WIRING IN ACCORDANCE WITH

ARCHITECTURAL MILLWORK. ALL INSTALLATIONS SHALL

COMPLY WITH ADA REQUIREMENTS.

B. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS BEFORE

ANY ROUGH-IN IN ORDER TO COORDINATE

MANUFACTURER'S DRAWINGS FOR EQUIPMENT LOCATION

AND INSTALLATION ACCESSORIES.

C. COORDINATE RUNS FOR CONDUIT UP IN JOIST AND FOR

SUSPENDING REQUIREMENTS IN ACCORDANCE WITH

STRUCTURAL PLANS.

D. ALL CAMERA DEVICES SHALL BE STUBBED UP TO ABOVE

ACCESSIBLE CEILING AND TO CABLE TRAY IF PRESENT.

THE CONTRACTOR SHALL PROVIDE J-HOOKS AND

CONDUITS TO EXTEND CABLING TO WALLS.

E. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL

USE THE EZ PATH SERIES FIRE-RATED ZERO

MAINTENANCE PATHWAY UNO. FOLLOW MANUFACTURER

USAGE AND INSTALLATION INSTRUCTIONS. REFER TO

DETAIL 1 ON SHEET TN502.

F. CONDUITS SHALL BE REAMED AND COMPLETED WITH

CONNECTORS AND INSULATED BUSHINGS AT BOTH ENDS.

G. BETWEEN ANY TWO PULL POINTS THERE SHALL BE NO

CONDUIT WITH GREATER THAN 180 DEGREES OF BENDS

OR EQUIVALENT.

H. WHERE CONDUIT LENGTH EXCEEDS 100FT AND/OR TWO

90 DEGREE BENDS OR EQUIVALENT PROVIDE PULL

BOXES AS REQUIRED.

I. ALL ZONE CONDUITS (HOME RUN) FOR LOW VOLTAGE

COMMUNICATIONS CABLING SHALL BE MARKED AT THEIR

TERMINUS WITH A TAG THAT IDENTIFIES "FIRE ALARM,

DATA, INTERCOM, ETC" (ROOM NAME AND NUMBER)

WHERE THE OTHER END OF THE CONDUIT TERMINATES.

J. ALL CABLES ABOVE CEILING SHALL BE PLENUM RATED.

ALL CABLES BELOW SLAB SHALL BE INDOOR/OUTDOOR

RATED.

K. FURNISH AND INSTALL 8'H X 4'W X 3/4"T VERTICALLY

HUNG, GRADE AC, PLYWOOD IN COMMUNICATION ROOMS

AS INDICATED ON PLANS. PAINT PLYWOOD WITH TWO

COATS OF FIRE RETARDANT TO MATCH EXISTING WALL

FINISH. COORDINATE WITH ARCHITECT, PRIME

CONTRACTOR, AND OWNER FOR INSTALLATION OF

BACKBOARD. REFER TO DRAWINGS FOR PROPOSED

LOCATION AND DETAILS.

L. MINIMUM CONDUIT SIZE FOR TWISTED PAIR CABLING

(LOW VOLTAGE) SHALL BE NOT SMALLER THAN 1" TRADE

SIZE.

M. THE CONTRACTOR SHALL FULLY REVIEW ALL ELECTRICAL

POWER PLANS TO IDENTIFY ALL RESPONSIBILITIES AND

SCOPE OF WORK.

N. ABOVE CEILING CABLE SUPPORTING HARDWARE. IN

CONJUNCTION WITH THE SPECIFIED CABLE TRAY,

ACCEPTABLE METHOD INCLUDES BUT IS NOT LIMITED TO

J-HOOKS. CABLE SHOULD BE PROPERLY SUPPORTED

WITH J-HOOK PATHWAY INSTALLED EVERY 3-5 FT.

CABLE CROSS SECTION AREA SHOULD BE CALCULATED

TO A 40% RATIO.

O. DATA CABLES FOR CAMERAS SHALL BE CAT-6A WITH

YELLOW JACKET, JACKS, AND MATCHING PATCH CABLES.

P. DATA CABLES FOR ACCESS CONTROL SHALL BE CAT-6A

WITH WHITE JACKET, JACKS, AND MATCHING PATCH

CABLES.

SECURITY PLAN NOTES

ABS ABOVE BACK SPLASH

ACT ABOVE COUNTER TOP

AFF ABOVE FINISHED FLOOR

BAS BUILDING AUTOMATION SYSTEM

BFC BELOW FINISHED CEILING

BOCT BOTTOM OF CABLE TRAY

C CONDUIT

CLG CEILING

CM SECURITY CAMERA

EC EMPTY CONDUIT

EF ENTRANCE FACILITY

ER EQUIPMENT ROOM

EX EXISTING

G GROUND (EQUIPMENT)

GEC GROUND ELECTRODE CONDUCTOR

MTD MOUNT OR MOUNTED

NIC NOT IN CONTRACT

PNL PANEL

S.O. SPACE ONLY

SP SPARE/SPACE

TR TELECOMMUNICATIONS ROOM

TYP TYPICAL

UF UNDERFLOOR

UG UNDERGROUND

WG WIRE GUARD

WP WEATHERPROOF

UNO UNLESS NOTED OTHERWISE

SECURITY GENERAL ABBREVIATIONSSECURITY SYMBOLS LEGEND

ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS.

SYMBOLS ARE SHOWN SCHEMATIC AND MAY NOT BE TO

SCALE.

SYMBOL DESCRIPTION

NOTES:

1. MOUNT ALL DEVICES AS INDICATED ABOVE, UNO ON PLAN

2. 48" AFF INDICATES TO TOP OF DEVICE

15" AFF INDICATES TO BOTTOM OF DEVICE

ALL OTHER MOUNTING HEIGHTS INDICATE TO CENTERLINE

OF DEVICE

WALL MOUNTED CAMERA - CONTRACTOR SHALL

FURNISH AND INSTALL SINGLE GANG BACK

BOX WITH CONDUIT TO ACCESSIBLE AREA AT

THIS LOCATION. PROVIDE WITH (1) YELLOW

CAT-6A CABLE.

CEILING MOUNTED CAMERA - CONTRACTOR

SHALL FURNISH AND INSTALL SINGLE GANG

BACK BOX WITH CONDUIT TO ACCESSIBLE

AREA AT THIS LOCATION. PROVIDE WITH (1)

YELLOW CAT-6A CABLE.

ELECTRIC LOCK WITH BUILT IN CARD

READER. REFERENCE DOOR HARDWARE

SCHEDULE ON ARCHITECTURAL PLANS.

REFERENCE 4/TY503 SINGLE SWINGING DOOR

WITH CARD READER FOR MOBILE ACCESS.

PROVIDE WITH WHITE CAT-6A CABLE FROM

PATCH PANEL TO DOOR CONTROLLER.

PROVIDE WITH MANUFACTURER APPROVED

SECURITY CABLE FROM DOOR CONTROLLER TO

SECURITY DEVICES.

EL

INTERIOR ALCATRAZ ROCK BIOMETRIC FACIAL

RECOGNITION DEVICE. WALL MOUNTED AT 62"

AFF TO CENTER OF DEVICE. CONTRACTOR TO

INSTALL 2-GANG SWITCH BOX WITH 1"

CONDUIT TO ACCESSIBLE AREA ABOVE

CEILING. PROVIDE WITH (1) WHITE CAT-6A

CABLE.

CORNER MOUNTED CAMERA - CONTRACTOR

SHALL FURNISH AND INSTALL SINGLE GANG

BACK BOX WITH CONDUIT TO ACCESSIBLE

AREA AT THIS LOCATION. PROVIDE WITH (1)

YELLOW CAT-6A CABLE.

RK1

EXTERIOR ALCATRAZ ROCK BIOMETRIC

FACIAL RECOGNITION DEVICE. WALL MOUNTED

AT 62" AFF TO CENTER OF DEVICE.

CONTRACTOR TO INSTALL 2-GANG SWITCH

BOX WITH 1" CONDUIT TO ACCESSIBLE AREA

ABOVE CEILING. PROVIDE WITH (1) WHITE

CAT-6A CABLE TO THE MIDSPAN. PROVIDE

WITH (1) OUTSIDE PLANT CAT-6A CABLE

FROM MIDSPAN TO ROCK-X DEVICE.

RK2

DUAL POLE DOOR CONTACT TO BE

MONITORED BY ACCESS CONTROL AND

INTRUSION DETECTION SYSTEMS. TO BE

FURNISHED AND INSTALLED BY

CONTRACTOR.

DC

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FLORIDA 32309

TEL. (850) 224-4400

HALFF ASSOCIATES, INC.

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FL 32309

GABRIEL BENAVIDES JR. P.E

PE NO. 97009

T H E

O F F

IC

IA

L

R E C O R D

O F

T H

IS

S

E E T

E

E L E C T R O N

IC

F

IL

E

D

IG

IT

A L L Y

S

IG

N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

FINANCIAL PROJECT IDCOUNTYROAD NO.

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

TY001SECURITY GENERAL NOTES AND

LEGENDS

ESCAMBIA 451524-1-38-01

NORTH W

STREET

SECURITY SHEET INDEX

SHEET

SHEET TITLE

TY001 SECURITY GENERAL NOTES AND LEGENDS

TY101 SECURITY OVERALL FLOOR PLAN

TY102 SECURITY FLOOR PLAN NORTH

TY103 SECURITY FLOOR PLAN SOUTH

TY401 SECURITY SCHEDULES

TY501 SECURITY DETAILS I

TY502 SECURITY DETAILS II

TY503 SECURITY DETAILS III

TY504 SECURITY DETAILS IV

No. Date Issue / Revision ah3602 Snapshot

R

TY103

TY102

?C16

C01C17

?C13

?C09

?C11

?C12

?C05

?C03

?C01

?C15

C01C14

?C18

?C04

?C06

C01C02

?C08

?C10

?C07

LEGEND

COLLISION DETECTION - IDENTIFY ZONE

COLLISION DETECTION - OBSERVE ZONE

COLLISION DETECTION - DEAD ZONE

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FLORIDA 32309

TEL. (850) 224-4400

HALFF ASSOCIATES, INC.

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FL 32309

GABRIEL BENAVIDES JR. P.E

PE NO. 97009

T H E

O F F

IC

IA

L

R E C O R D

O F

T

E E

E

E L E C T R O

E

D

IG

IT

A L L Y

S

IG

N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

FINANCIAL PROJECT IDCOUNTYROAD NO.

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

TY101

SECURITY OVERALL FLOOR PLAN

ESCAMBIA 451524-1-38-01

NORTH W

STREET

SECURITY OVERALL FLOOR PLAN

10'0' 40'20'

GENERAL NOTES:

A. REFER TO SHEET TY001 FOR SECURITY GENERAL LEGEND

AND NOTES.

B. THE INTENT OF THIS DRAWING IS TO DEMONSTRATE

GENERAL AREAS OF COVERAGE OF THE DISTINCT CAMERA

MODELS USED IN THIS SET OF DRAWINGS. SHOULD OTHER

CAMERA MODELS OR MANUFACTURERS BE USED IN PROJECT

IN LEIU OF THOSE SPECIFIED, THIS DRAWING SHOULD BE

NO LONGER APPLICABLE. SHOULD THE CONTRACTOR OPT TO

SUBMIT ON A ALTERNATIVE CAMERA SYSTEM, IT SHALL BE

SUBMITTED WITH AN EQUAL OR BETTER MODEL AS SHOWIN

ON THIS SHEET. NO EXCEPTIONS.

No. Date Issue / Revision

EL

DC

E

L

DC

DC

EL

D

C

E L

E L

D C

DC DC

DC

RK2

RK1

?C03

?C01

C01C14

?C15

?C16

C01C17

107B

107A

120.3

119B ?C04

C01C02

R E F

T Y

R E F

T Y

132A

FILE

STORAGE

MEDIA

ROOM

NEXUS

CONFERENCE

COLLAB

OFFICE

COLLAB

OFFICE

COLLAB

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

RESTROOM

RESTROOM

CORRIDOR

120.2

CORRIDOR

120.1

CORRIDOR

120.3

AUTO

COLLABORATION

OPEN

OFFICE

RESTROOM

114CORRIDOR

120.5

SUPPLIES

/ TECH

CORRIDOR

120.4

JANITORIAL

/ UTILITY

DATA

VISUALIZATION

SUPPORT

115.2

ELEC.

MAIL /

SUPPLIES

COORIDOR

DIGITAL

RECEPTION

VESTIBULE

DATA

VISUALIZATION

SPACE

115.1

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FLORIDA 32309

TEL. (850) 224-4400

HALFF ASSOCIATES, INC.

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FL 32309

GABRIEL BENAVIDES JR. P.E

PE NO. 97009

T H E

O F F

IC

IA

L

R E C O R D

O F

T

E E

E

E L E C T R O

E

D

IG

IT

A L L Y

S

IG

N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

FINANCIAL PROJECT IDCOUNTYROAD NO.

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

TY102

SECURITY FLOOR PLAN NORTH

ESCAMBIA 451524-1-38-01

NORTH W

STREET

SECURITY FLOOR PLAN NORTH

GENERAL NOTES:

A. REFER TO SHEET TY001 FOR SECURITY GENERAL LEGEND

AND NOTES.

4'0' 16'8'

No. Date Issue / Revision

D C

D C

DC

D C

DCDC

DCDC

D C

E L

E L

E L

EL

R K

EL

EL

?C05

?C13

?C18 ?C11

?C12

147A

147B

136B

R E F

T Y

136.1

136A

?C06

?C07

?C09

?C10

?C08

R E F

T Y

FAMILY

FAMILY

RTMC

TRAINING/MEETING

ROOM

FOOD

STORAGE

TMC

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

SERVER/BENCH

TEST

OFFICE

MEN

CHASE

WOMEN

FURNITURE

STORAGE

MECHANICAL

ELEC

FIRE

SUPPRESSION

OFFICE

CORRIDOR

BREAK

ROOM

MEDIA

COVERAGE

ROOM

FOOD

STORAGE

BREAK

ROOM

CORRIDOR

CONTROL

ROOM

CORRIDOR

136.1

UPS

CORRIDOR

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FLORIDA 32309

TEL. (850) 224-4400

HALFF ASSOCIATES, INC.

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FL 32309

GABRIEL BENAVIDES JR. P.E

PE NO. 97009

T H E

O F F

IC

IA

L

R E C O R D

O F

T

E E

E

E L E C T R O

E

D

IG

IT

A L L Y

S

IG

N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

FINANCIAL PROJECT IDCOUNTYROAD NO.

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

TY103

SECURITY FLOOR PLAN SOUTH

ESCAMBIA 451524-1-38-01

NORTH W

STREET

SECURITY FLOOR PLAN SOUTH

GENERAL NOTES:

A. REFER TO SHEET TY001 FOR SECURITY GENERAL LEGEND

AND NOTES.

4'0' 16'8'

No. Date Issue / Revision

CAMERA SCHEDULE

CAMERA ID FIELD OF VIEW ACCESSORIES

C01

DIV. 28 21 13

C02

C03

C04

C05

C06

C07

C08

C09

C10

C11

C12

C13

C14

C15

C16

C17

C18

SECTION 2.03.C

SECTION 2.03.D

SECTION 2.03.C

SECTION 2.03.E

SECTION 2.03.E

SECTION 2.03.E

SECTION 2.03.E

SECTION 2.03.C

SECTION 2.03.F

SECTION 2.03.F

SECTION 2.03.A

& 2.03.B

SECTION 2.03.E

SECTION 2.03.A

SECTION 2.03.A

SECTION 2.03.E

SECTION 2.03.A

& 2.03.B

SECTION 2.03.A

& 2.03.B

SECTION 2.03.A

& 2.03.B

ORIENTATION

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

360°

180°

360°

360°

180°

180°

180°

180°

360°

90°

90°

360° W/ PTZ

180°

360°

360°

360° W/ PTZ

360° W/ PTZ

360° W/ PTZ

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MANUFACTURE APPROVED MOUNTING HARDWARE

MOUNTING LOCATION MOUNTING TYPE

INDOOR

INDOOR

INDOOR

INDOOR

INDOOR

INDOOR

INDOOR

INDOOR

INDOOR

INDOOR

OUTDOOR UNDER SOFFIT

OUTDOOR UNDER SOFFIT

OUTDOOR UNDER SOFFIT

OUTDOOR UNDER SOFFIT

OUTDOOR UNDER SOFFIT

OUTDOOR UNDER SOFFIT

OUTDOOR UNDER SOFFIT

OUTDOOR UNDER SOFFIT

CEILING

EXTERIOR WALL MOUNTED

INTERIOR CORNER WALL MOUNTED

CEILING

WALL MOUNTED AT 9 FT

WALL MOUNTED AT 9 FT

WALL MOUNTED AT 9 FT

WALL MOUNTED AT 9 FT

CEILING

WALL MOUNTED AT 9 FT

EXTERIOR CORNER WALL MOUNTED

EXTERIOR CORNER WALL MOUNTED

EXTERIOR WALL MOUNTED

EXTERIOR WALL MOUNTED

EXTERIOR CORNER WALL MOUNTED

EXTERIOR CORNER WALL MOUNTED

EXTERIOR CORNER WALL MOUNTED

WALL MOUNTED AT 9 FT

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FLORIDA 32309

TEL. (850) 224-4400

HALFF ASSOCIATES, INC.

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FL 32309

GABRIEL BENAVIDES JR. P.E

PE NO. 97009

T H E

O F F

IC

IA

L

R E C O R D

O F

T

E E

E

E L E C T R O

E

D

IG

IT

A L L Y

S

IG

N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

FINANCIAL PROJECT IDCOUNTYROAD NO.

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

TY401

SECURITY SCHEDULES

ESCAMBIA 451524-1-38-01

NORTH W

STREET

31 DOOR CONTACT - SERVER/BENCH TEST 147 - DOOR#147B

30 DOOR CONTACT - SERVER/BENCH TEST 147 - DOOR#147B

29 ELECTRIC LOCK - SERVER/BENCH TEST 147 - DOOR#147B

28 DOOR CONTACT - SERVER/BENCH TEST 147 - DOOR#147A

27 DOOR CONTACT - SERVER/BENCH TEST 147 - DOOR#147A

26 ELECTRIC LOCK - SERVER/BENCH TEST 147 - DOOR#147A

25 DOOR CONTACT - CORRIDOR 136 - DOOR#136B

24 ELECTRIC LOCK - CORRIDOR 136 - DOOR#136B

23 DOOR CONTACT - CORRIDOR 136 - DOOR#136A

22 ELECTRIC LOCK - CORRIDOR 136 - DOOR#136A

21 DOOR CONTACT - CONTROL ROOM 148 - DOOR#136.1

20 ELECTRIC LOCK - CONTROL ROOM 148 - DOOR#136.1

19 DOOR CONTACT - CORRIDOR 133 - DOOR#133

18 ROCK 1 - CORRIDOR 133 - DOOR#133

17 DOOR CONTACT - CORRIDOR 130 - DOOR#130

16 ELECTRIC LOCK - CORRIDOR 130 - DOOR#130

15 DOOR CONTACT - CORRIDOR 120.3 - DOOR#120.3

14 ELECTRIC LOCK - CORRIDOR 120.3 - DOOR#120.3

13 DOOR CONTACT - OPEN OFFICE 120 - DOOR#120

12 ELECTRIC LOCK - OPEN OFFICE 120 - DOOR#120

11 DOOR CONTACT - OPEN OFFICE 120 - DOOR#119B

10 ROCK 1 - OPEN OFFICE 120 - DOOR#119B

9 DOOR CONTACT - VESTIBULE 119 - DOOR#119A

8 DOOR CONTACT - VESTIBULE 119 - DOOR#119A

7 ROCKX 2 - VESTIBULE 119 - DOOR#119A

6 DOOR CONTACT - MEDIA ROOM 107 - DOOR#107B

5 ELECTRIC LOCK - MEDIA ROOM 107 - DOOR#107B

4 DOOR CONTACT - MEDIA ROOM 107 - DOOR#107A

3 ELECTRIC LOCK - MEDIA ROOM 107 - DOOR#107A

2 DOOR CONTACT - FILE STORAGE 106 - DOOR#106

1 ELECTRIC LOCK - FILE STORAGE 106 - DOOR#106

CKT Circuit Description

Location: SERVER/BENCH TEST 147

SECURITY PATCH PANEL 1 - ACCESS CONTROL

18 C18 - EXTERIOR WALL

17 C17 - EXTERIOR CORNER WALL

16 C16 - EXTERIOR CORNER WALL

15 C15 - EXTERIOR CORNER WALL

14 C14 - EXTERIOR CORNER WALL

13 C13 - EXTERIOR WALL

12 C12 - EXTERIOR CORNER WALL

11 C11 - EXTERIOR CORNER WALL

10 C10 - SERVER/BENCH TEST 147

9 C09 - SERVER/BENCH TEST 147

8 C08 - CORRIDOR 136

7 C07 - CONTROL ROOM 148

6 C06 - CONTROL ROOM 148

5 C05 - CORRIDOR 130

4 C04 - VESTIBULE 119

3 C03 - CORRIDOR 120.4

2 C02 - OPEN OFFICE 120

1 C01 - CORRIDOR 120.2

CKT Circuit Description

Location: SERVER/BENCH TEST 147

SECURITY PATCH PANEL - CAMERAS

No. Date Issue / Revision

COMPONENTS OF INDUSTRIAL IOT INTEGRATION

1. INDUSTRIAL IOT PLUGIN ROLE: WITH THE INDUSTRIAL IOT PLUGIN, YOU CAN CREATE THE

INDUSTRIAL IOT ROLE. THROUGH THIS ROLE, SECURITY CENTER CAN COMMUNICATE WITH

IOT DEVICES. THE PLUGIN ROLE CAN RAISE EVENTS AND TRIGGER ALARMS WHEN DATA

CHANGES OCCUR ON THESE DEVICES.

2. CONFIG TOOL: THE INDUSTRIAL IOT PLUGIN MUST BE INSTALLED ON A CONFIG TOOL

WORKSTATION. THE SECURITY CENTER ADMINISTRATOR USES CONFIG TOOL TO CREATE AND

CONFIGURE THE PLUGIN ROLE.

3. SECURITY DESK: THE INDUSTRIAL IOT PLUGIN MUST BE INSTALLED ON ALL SECURITY

DESK WORKSTATIONS. SECURITY DESK OPERATORS CAN VIEW STATE CHANGES IN REAL

TIME ON MAPS.

4. BACNET DEVICES: DEVICES THAT USE THE BACNET PROTOCOL TO COMMUNICATE WITH THE

PLUGIN ROLE. WHEN REQUESTED BY THE PLUGIN ROLE, THE BACNET DEVICES REPLY WITH

THEIR CURRENT DATA AND STATES.

5. TCP SERVER: THE PLUGIN ROLE RECEIVES DATA AND EVENTS FROM DEVICES CONNECTED

TO A TCP SERVER RUN BY THE PLUGIN ROLE. THE TCP SERVER MUST BE CONFIGURED TO

IDENTIFY DATA AND EVENTS BY EVALUATING THE PAYLOAD SENT BY THESE DEVICES

AGAINST REGULAR EXPRESSIONS.

2 3

8" WHITE PATCH CABLES

COPPER PATCH

PANEL ETHERNET

SWITCH

8" YELLOW PATCH CABLES

COPPER PATCH

PANEL ETHERNET

SWITCH

FILLER PANEL

(WHITE) ACCESS CONTROL PANEL/SWITCH

FILLER PANEL

(YELLOW) CAMERAS PANEL/SWITCH

FILLER PANEL

FILLER PANEL

FILLER PANEL

FILLER PANEL

FILLER PANEL

ELECTRONIC SAFETY & SECURITY CABINET 5

FRONT VIEW

ELECTRONIC SAFETY &

SECURITY CABINET 5

REAR VIEW

GENETEC STREAMVAULT

FILLER PANEL

FILLER PANEL

FILLER PANEL

FILLER PANEL

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FLORIDA 32309

TEL. (850) 224-4400

HALFF ASSOCIATES, INC.

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FL 32309

GABRIEL BENAVIDES JR. P.E

PE NO. 97009

T H E

O F F

IC

IA

L

R E C O R D

O F

T

E E

E

E L E C T R O

E

D

IG

IT

A L L Y

S

IG

N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

FINANCIAL PROJECT IDCOUNTYROAD NO.

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

TY501

SECURITY DETAILS I

ESCAMBIA 451524-1-38-01

NORTH W

STREET

HYBRID GENETEC ARCHITECTURE DATA FLOW DIAGRAM

TYPICAL COPPER PATCH PANEL JACK TO ETHERNET SWITCH PORT DETAIL - ACCESS CONTROL

TYPICAL COPPER PATCH PANEL JACK TO ETHERNET SWITCH PORT DETAIL - CAMERAS

ARCHITECTURE DIAGRAM FOR INDUSTRIAL IoT INTEGRATION

UNIFIED SECURITY CENTER PLATFORM

No. Date Issue / Revision

TYPICAL WALL MOUNT

WALL MOUNT

BRACKET

WALL MOUNT

BRACKET

WALL

WALL

TYPICAL CORNER WALL MOUNT

CORNER MOUNT

PLATE

PoE SWITCH

ETHERNET SURGE

PROTECTOR

ETHERNET SURGE PROTECTOR

BASIS OF DESIGN: AXIS T8061

ETHERNET SURGE

PROTECTOR

ETHERNET SURGE

PROTECTOR

ETHERNET SURGE

PROTECTOR

WEATHER-PROOF

COVER FOR J-BOX

CAMERA

CONDUIT

J-BOX RECESSED

INSIDE WALL

FILL CONDUIT AT CMU

PENETRATION WITH

FIRE SEALANT BUSHING

DEVICE MANUFACTURER

BACK BOX

PROVIDE CONDUIT

STRAP @ 24"

CENTERS

ELECTRICAL BOX, WIRING TERMINAL

BLOCK, SURGE PROTECTION DEVICE

BASIS OF DESIGN: AXIS T8061

CONDUIT (EMT)

FILL CONDUIT AT CMU PENETRATION

WITH FIRE SEALANT BUSHING

NEAREST

IT ROOM

PROVIDE CONDUIT

SUPPORTS/TIES

FOR STRUCTURAL

MEMBERS PER NEC

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FLORIDA 32309

TEL. (850) 224-4400

HALFF ASSOCIATES, INC.

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FL 32309

GABRIEL BENAVIDES JR. P.E

PE NO. 97009

T H E

O F F

IC

IA

L

R E C O R D

O F

T

E E

E

E L E C T R O

E

D

IG

IT

A L L Y

S

IG

N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

FINANCIAL PROJECT IDCOUNTYROAD NO.

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

TY502

SECURITY DETAILS II

ESCAMBIA 451524-1-38-01

NORTH W

STREET

TYPICAL CAMERA WALL MOUNT DETAIL WITH CORNER MOUNT

TYPICAL ETHERNET SURGE PROTECTION DETAIL

TYPICAL CONDUIT PENETRATION DETAIL

No. Date Issue / Revision

DOOR

CONTACT

DOOR

CONTACT

IP

DOOR

CONTROLLER

TO PoE NETWORK SWITCH

CEILING LINE

KEY

REMOVABLE

MULLION

POWER

TRANSFER

POWER

TRANSFER

ELECTRIFIED

DEVICE

ELECTRIFIED

DEVICE

GENERAL NOTES :

A. ALL CONDUITS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR.

B. ALL LOW VOLTAGE WIRING SHALL BE PROVIDED BY SECURITY

CONTRACTOR.

C. ELECTRICAL AND SECURITY CONTRACTORS SHALL COORDINATE WITH DOOR

HARDWARE CONTRACTOR FOR CONDUIT ROUTING AND WIRING OF ACCESS

CONTROL SYSTEM. ELECTRICAL CONTRACTOR SHALL CONCEAL CONDUIT AS

MUCH AS POSSIBLE BY ROUTING IT THROUGH FRAMING ELEMENTS.

D. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR DOOR

HARDWARE.

E. PROVIDE WITH NEMA 1 ENCLOSURE WITH BUSHINGS, MOUNTING PANEL,

GROUNDING AND SUPPORTING MEANS. ELECTRICAL CONTRACTOR SHALL

TERMINATE ALL DOOR SECURITY SYSTEM CONDUITS AT NEMA 1

ENCLOSURE.

F. THIS DETAIL IS FOR REFERENCE ONLY.

G. POWER SUPPLY SHALL BE PROVIDED WITH DOOR HARDWARE.

CAT 6

CAT 6

12/24 VDC DOOR

LOCKING DEVICE

FURNISH AND INSTALL (1)

3/4" CONDUIT FOR ADA PUSH

BUTTON PEDESTAL. FIELD

COORDINATE EXACT LOCATION

OF ADA PUSH BUTTON

PEDESTAL WITH OWNER

REPRESENTATIVE.

TO PoE NETWORK SWITCH

ALCATRAZ ROCK MOUNT 62"

AFF WITHIN 6" OF DOORDOOR

CONTACT

CEILING LINE

POWER

TRANSFER

ELECTRIFIED

DEVICE

GENERAL NOTES :

A. ALL CONDUITS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR.

B. ALL LOW VOLTAGE WIRING SHALL BE PROVIDED BY SECURITY

CONTRACTOR.

C. ELECTRICAL AND SECURITY CONTRACTORS SHALL COORDINATE WITH DOOR

HARDWARE CONTRACTOR FOR CONDUIT ROUTING AND WIRING OF ACCESS

CONTROL SYSTEM. ELECTRICAL CONTRACTOR SHALL CONCEAL CONDUIT AS

MUCH AS POSSIBLE BY ROUTING IT THROUGH FRAMING ELEMENTS.

D. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR DOOR

HARDWARE.

E. PROVIDE WITH NEMA 1 ENCLOSURE WITH BUSHINGS, MOUNTING PANEL,

GROUNDING AND SUPPORTING MEANS. ELECTRICAL CONTRACTOR SHALL

TERMINATE ALL DOOR SECURITY SYSTEM CONDUITS AT NEMA 1

ENCLOSURE.

F. THIS DETAIL IS FOR REFERENCE ONLY.

G. POWER SUPPLY SHALL BE PROVIDED WITH DOOR HARDWARE.

12/24 VDC DOOR

LOCKING DEVICE

CAT 6

ALCATRAZ ROCK MOUNT 62"

AFF WITHIN 6" OF DOOR

IP

DOOR

CONTROLLER

TO PoE NETWORK SWITCH

CAT 6

TO PoE NETWORK SWITCH

DOOR

CONTACT

CEILING LINE

REQUEST TO EXIT, IF

REQUIRED IS

SUPPLIED BY THE

SECURITY CONTRACTOR

GENERAL NOTES :

A. ALL CONDUITS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR.

B. ALL LOW VOLTAGE WIRING SHALL BE PROVIDED BY SECURITY

CONTRACTOR.

C. ELECTRICAL AND SECURITY CONTRACTORS SHALL COORDINATE WITH DOOR

HARDWARE CONTRACTOR FOR CONDUIT ROUTING AND WIRING OF ACCESS

CONTROL SYSTEM. ELECTRICAL CONTRACTOR SHALL CONCEAL CONDUIT AS

MUCH AS POSSIBLE BY ROUTING IT THROUGH FRAMING ELEMENTS.

D. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR DOOR

HARDWARE.

E. PROVIDE WITH NEMA 1 ENCLOSURE WITH BUSHINGS, MOUNTING PANEL,

GROUNDING AND SUPPORTING MEANS. ELECTRICAL CONTRACTOR SHALL

TERMINATE ALL DOOR SECURITY SYSTEM CONDUITS AT NEMA 1

ENCLOSURE.

F. THIS DETAIL IS FOR REFERENCE ONLY.

TO PoE NETWORK SWITCH

CAT 6

IP

DOOR

CONTROLLER

CAT 6

TO PoE NETWORK SWITCH

ALCATRAZ ROCK MOUNT 62"

AFF WITHIN 6" OF DOOR

POWER

TRANSFER

12/24 VDC DOOR

LOCKING DEVICE

DOOR

CONTACT

CEILING LINE

REQUEST TO EXIT, IF

REQUIRED IS

SUPPLIED BY THE

SECURITY CONTRACTOR

GENERAL NOTES :

A. ALL CONDUITS SHALL BE PROVIDED BY ELECTRICAL

CONTRACTOR.

B. ALL LOW VOLTAGE WIRING SHALL BE PROVIDED BY SECURITY

CONTRACTOR.

C. ELECTRICAL AND SECURITY CONTRACTORS SHALL COORDINATE

WITH DOOR HARDWARE CONTRACTOR FOR CONDUIT ROUTING

AND WIRING OF ACCESS CONTROL SYSTEM. ELECTRICAL

CONTRACTOR SHALL CONCEAL CONDUIT AS MUCH AS POSSIBLE

BY ROUTING IT THROUGH FRAMING ELEMENTS.

D. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR

DOOR HARDWARE.

E. PROVIDE WITH NEMA 1 ENCLOSURE WITH BUSHINGS,

MOUNTING PANEL, GROUNDING AND SUPPORTING MEANS.

ELECTRICAL CONTRACTOR SHALL TERMINATE ALL DOOR

SECURITY SYSTEM CONDUITS AT NEMA 1 ENCLOSURE.

F. THIS DETAIL IS FOR REFERENCE ONLY.

TO PoE NETWORK SWITCH

CAT 6

IP

DOOR

CONTROLLER

POWER

TRANSFER

12/24 VDC DOOR

LOCKING DEVICE

FINISHED FLOOR

DOOR HARDWARE

INTEGRATED ACCESS

CONTROL CARD

READER ON OTHER

SIDE OF DOOR.

KEY LEVER

DOOR

CONTACT

CEILING LINE

REQUEST TO EXIT, IF

REQUIRED IS

SUPPLIED BY THE

SECURITY CONTRACTOR

GENERAL NOTES :

A. ALL CONDUITS SHALL BE PROVIDED BY ELECTRICAL

CONTRACTOR.

B. ALL LOW VOLTAGE WIRING SHALL BE PROVIDED BY SECURITY

CONTRACTOR.

C. ELECTRICAL AND SECURITY CONTRACTORS SHALL COORDINATE

WITH DOOR HARDWARE CONTRACTOR FOR CONDUIT ROUTING

AND WIRING OF ACCESS CONTROL SYSTEM. ELECTRICAL

CONTRACTOR SHALL CONCEAL CONDUIT AS MUCH AS POSSIBLE

BY ROUTING IT THROUGH FRAMING ELEMENTS.

D. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR

DOOR HARDWARE.

E. PROVIDE WITH NEMA 1 ENCLOSURE WITH BUSHINGS,

MOUNTING PANEL, GROUNDING AND SUPPORTING MEANS.

ELECTRICAL CONTRACTOR SHALL TERMINATE ALL DOOR

SECURITY SYSTEM CONDUITS AT NEMA 1 ENCLOSURE.

F. THIS DETAIL IS FOR REFERENCE ONLY.

TO PoE NETWORK SWITCH

CAT 6

IP

DOOR

CONTROLLER

POWER

TRANSFER

12/24 VDC DOOR

LOCKING DEVICE

FINISHED FLOOR

DOOR HARDWARE

INTEGRATED ACCESS

CONTROL CARD

READER ON OTHER

SIDE OF DOOR.

DOOR

CONTACT

POWER

TRANSFER

ELECTRIFIED

DEVICE

ELECTRIFIED

DEVICE

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FLORIDA 32309

TEL. (850) 224-4400

HALFF ASSOCIATES, INC.

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FL 32309

GABRIEL BENAVIDES JR. P.E

PE NO. 97009

T H E

O F F

IC

IA

L

R E C O R D

O F

T

E E

E

E L E C T R O

E

D

IG

IT

A L L Y

S

IG

N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

FINANCIAL PROJECT IDCOUNTYROAD NO.

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

TY503

SECURITY DETAILS III

ESCAMBIA 451524-1-38-01

NORTH W

STREET

PAIR OF DOORS WITH ALCATRAZ ROCK ACCESS2

SINGLE DOOR WITH ALCATRAZ ROCK ACCESS

SINGLE OUT & IN SWINGING DOOR WITH ALCATRAZ ROCK ACCESS

SINGLE SWINGING DOOR WITH CARD READER FOR MOBILE ACCESS

DOUBLE DOOR WITH CARD READER FOR MOBILE ACCESS

No. Date Issue / Revision

INSTALL ON DOOR

OPENING SIDE

2-GANG SWITCH BOX

BADGE READER

INSTALLED AT

STANDARD HEIGHT

62" (157cm) FROM FLOOR

TO CENTER OF BOX

FOR BEST PERFORMANCE

PLACE WITHIN 6"

(150mm) OF DOOR

LEAVE MINIMUM OF 1/2"

(13mm)BETWEEN 2-GANG

SWITCH BOX AND DOOR

FRAME.

(1 m m M

IN

IM

U M

SCREW TABS

MUST BE IN

VERTICAL

POSITION

LEAVE MINIMUM 3" (76mm)

OF SPACE ON OUTER EDGE

FOR COOLING AND FOR

TOOL TO REMOVE ROCK

OPTIONAL

IP DOOR

CONTROLLER

PoE+

ETHERNETUNSHIELDED

CAT6

OSDP CABLE

ALCATRAZ

ROCK

CONNECTION OVERVIEW

UNSHIELDED

CAT6 CABLE

IP DOOR

CONTROLLER

PoE+ ETHERNET

UNSHIELDED OSP

CAT6 CABLE

OSDP CABLE

ALCATRAZ

ROCK-X

EXTERIOR

UNSHIELDED

CAT6 CABLE

INTERIOR

UNSHIELDED

CAT6 CABLE

EXPANSION MODULE

MOUNTED ON WALL IN

ELECTRICAL ROOM 101

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FLORIDA 32309

TEL. (850) 224-4400

HALFF ASSOCIATES, INC.

2255 KILLEARN CENTER BLVD.

SUITE 200

TALLAHASSEE, FL 32309

GABRIEL BENAVIDES JR. P.E

PE NO. 97009

T H E

O F F

IC

IA

L

R E C O R D

O F

T

E E

E

E L E C T R O

E

D

IG

IT

A L L Y

S

IG

N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

FINANCIAL PROJECT IDCOUNTYROAD NO.

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

TY504

SECURITY DETAILS IV

ESCAMBIA 451524-1-38-01

NORTH W

STREET

ALCATRAZ INSTALLATION GUIDE DETAIL

OSDP WIRE CABLE TO IP DOOR CONTROLLER

ROCK-X EXTERIOR WIRE CABLE TO IP DOOR CONTROLLER AND NETWORK FOR BUILDING MOUNTED EXTERIOR DOOR LOCATIONS

IP-DOOR CONTROLLER DETAIL

No. Date Issue / Revision

Sheets
TY001 - SECURITY GENERAL NOTES AND LEGENDS
TY101 - SECURITY OVERALL FLOOR PLAN
TY102 - SECURITY FLOOR PLAN NORTH
TY103 - SECURITY FLOOR PLAN SOUTH
TY401 - SECURITY SCHEDULES
TY501 - SECURITY DETAILS I
TY502 - SECURITY DETAILS II
TY503 - SECURITY DETAILS III
TY504 - SECURITY DETAILS IV
2025-04-01T14:14:14-0500
Gabriel Benavides Jr.