451524-1-38-01_05_FIRE_PROTECTION_S&S_.pdf

PDF 539 KB Posted

Attached to
LAP - Regional Traffic Management Center Facility Construction Federal Funded Project FPID: D324-034B
Solicitation number
PD 24-25.086
Issued by
Escambia County, Florida

About this file

The provided documents are Fire Protection General Notes and Details for the Regional Traffic Management Center Facility Construction project, prepared by WGI, Inc. for the Florida-Alabama Transportation Planning Organization (FL-AL TPO) in Escambia County, Florida. The fire protection documentation details comprehensive fire suppression system requirements for a new 19,940 square foot transportation management center, including specific design standards, system types, and installation guidelines conforming to multiple codes such as the Florida Building Code, Florida Fire Prevention Code, and National Fire Protection Association (NFPA) standards.

The fire protection system will utilize multiple fire suppression approaches, including a wet pipe sprinkler system for most areas designed to ordinary and light hazard specifications, with specific zones like the UPS room and server/IT room protected by clean agent gas fire protection systems with pre-action single interlock systems. The project requires adherence to strict installation standards, including use of Schedule 40 steel piping, specific sprinkler head types, hydraulic calculations, and comprehensive testing protocols. The system design incorporates detailed requirements for pipe sizing, support, penetration protection, and coordination with other building systems, with all materials requiring UL listing or FM approval and installation by qualified personnel.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL FIRE PROTECTION NOTES

1. ALL FIRE PROTECTION WORK SHALL MEET ALL OF THE REQUIREMENTS OF THE FOLLOWING:

A. FLORIDA BUILDING CODE (FBC) 8TH EDITION (2023) (EFFECTIVE DECEMBER 31, 2023): THIS CODE

INCLUDES THE 2023 FBC BUILDING, MECHANICAL, PLUMBING, ENERGY CONSERVATION, FUEL GAS, ACCESSIBILITY, AND TEST PROTOCOLS VOLUMES. FURTHER, SEE "REFERENCED STANDARDS" IN THE

FBC BUILDING CHAPTER 35; FBC MECHANICAL CHAPTER 15; FBC PLUMBING CHAPTER 15; FBC

ENERGY CONSERVATION CHAPTER 6; AND FBC FUEL GAS CHAPTER 8).

B. 8TH EDITION OF THE FLORIDA FIRE PREVENTION CODE (FFPC): THIS CODE ALSO INCLUDES THE

FLORIDA VERSIONS OF NFPA 1 AND NFPA 101. (EFFECTIVE DECEMBER 31, 2023).

C. 2020 NATIONAL ELECTRIC CODE.

D. STATE OF FLORIDA, DEPARTMENT OF ENVIRONMENTAL REGULATION RULES.

E. FDOT BUILDING FACILITIES DESIGN MANUAL 625-202-016-F – REVISED MAY 2020.

F. NFPA 13 - STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2019.

G. NFPA 20 – STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION, 2019.

H. NFPA 2001 – STANDARD FOR THE INSTALLATION OF CLEAN AGENT EXTINGUISHING SYSTEMS, 2020.

I. PROVIDE FIRE PROTECTION SYSTEM IN ACCORDANCE WITH FAC 61G15-32.004 DESIGN OF WATER

BASED FIRE PROTECTION SYSTEMS.

2. PIPING SHALL BE SIZED BY HYDRAULIC CALCULATION METHOD NFPA 13 (2016).

3. FLUSH AND TEST SYSTEM IN ACCORDANCE WITH NFPA 13, AND 24.

4. PROVIDE PLANS AND HYDRAULIC CALCULATIONS IN CONFORMANCE WITH THE REQUIREMENTS OF NFPA 13

AND THE FLORIDA BUILDING CODE. PLANS AND CALCULATIONS SHALL BE SIGNED AND SEALED BY A

DELEGATED PROFESSIONAL ENGINEER, REGISTERED IN THE STATE OF FLORIDA AND SUBMITTED TO THE

AUTHORITY HAVING JURISDICTION (AHJ) FOR APPROVAL. PRIOR TO ISSUING PLANS AND CALCULATIONS, THE

DELEGATED PROFESSIONAL ENGINEER SHALL ISSUE A LETTER ADDRESSED TO STEPHEN R. FORKNER, PE, ON THEIR COMPANY LETTERHEAD, STATING THAT HE/SHE IS ACCEPTING THE ROLE AS ENGINEER OF

RECORD FOR THE FIRE PROTECTION PORTION OF THE PROJECT. ONCE STEPHEN R. FORKNER, PE RECEIVES

THE LETTER, HE WILL RELINQUISH THE TITLE OF ENGINEER OF RECORD TO THE DELEGATED

PROFESSIONAL ENGINEER.

5. SPRINKLER SYSTEMS SHALL BE INSTALLED BY PERSONNEL WHO HAVE ENGINEERING FACILITIES AND

EXPERIENCE IN SUCH WORK AND WHO ARE REGULARLY EMPLOYED TO DO SUCH WORK.

6. ALL MATERIALS SHALL BE OF APPROVED QUALITY AND THE WORK SHALL BE DONE IN A THOROUGH AND

WORKMANLIKE MANNER. THE WORK, MATERIALS AND TEST SHALL BE IN ACCORDANCE WITH THE CURRENT

REQUIREMENTS OF NFPA 13 AND 14.

7. SPRINKLERS SHALL BE 1/2" ORIFICE TYPE OF ORDINARY DEGREE RATING EXCEPT WHERE EXCESSIVE

TEMPERATURES ARE ANTICIPATED. IN THESE LOCATIONS, HIGH TEMPERATURE SPRINKLERS SHALL BE

INSTALLED IN ACCORDANCE WITH NFPA 13. THE CONTRACTOR SHALL INDICATE SPRINKLER TEMPERATURE

RATING, ORIFICE SIZE AND TYPE ON FINAL DRAWINGS. SPRINKLER AND ESCUTCHEON SHALL BE CHROME

PLATED.

8. COORDINATE EXACT LOCATION OF SPRINKLERS, PIPING, AND EQUIPMENT WITH CEILING, ELECTRICAL, MECHANICAL, AND STRUCTURAL COMPONENTS OF BUILDING. MAKE MODIFICATIONS WITHOUT ADDITIONAL

COST TO THE OWNER.

9. ALL MATERIAL SHALL BE UL LISTED OR FM APPROVED.

10. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL SMOKE AND FIRE RATED WALLS WHICH

FIRE PROTECTION PIPING PENETRATES. FIRE PROTECTION PIPING SHALL BE SMOKE/FIRE SAFED IN AN

APPROVED MANNER WHEN PENETRATING RATED WALLS AND FLOORS. PROVIDE SLEEVES OR OTHER

APPROVED MEANS AND SEAL OPENINGS IN WALLS, FLOORS, AND PARTITIONS IN SUCH A MANNER AS TO

MAINTAIN THE SMOKE AND FIRE RATING OF THAT WALL, FLOOR OR CEILING.

11. SPACING OF SPRINKLERS: THE SPACING AND SIZES OF PIPES SHALL CONFORM TO THE REQUIREMENTS OF

NFPA 13. SPRINKLERS SHALL BE WITHIN 1" OF CENTER OF ACOUSTICAL PANEL. PROVIDE SWING JOINT IF

REQUIRED TO ACCOMPLISH THIS. SPRINKLERS SHALL BE AT LEAST 6" FROM ANY CEILING FIXTURE.

COORDINATE THE LOCATION OF SPRINKLERS AND PIPING WITH THE ELECTRICAL AND MECHANICAL

DRAWINGS.

12. PIPE SUPPORTS, HANGERS, CLAMPS, RODS AND OTHER ACCESSORIES: SHALL BE OF AN APPROVED TYPE

AND IN SUFFICIENT NUMBER TO PROPERLY SUPPORT ALL PIPING. PIPING SHALL BE SUPPORTED BY ROUND

WROUGHT U-TYPE APPROVED ADJUSTABLE HANGERS. PROVIDE ALL HANGERS INCLUDING TRAPEZE

HANGERS AS REQUIRED TO COMPLY WITH NFPA 13. HANG TO TOP CHORD OF BAR JOIST ONLY.

13. ALL CONDUIT BETWEEN CONTROLLER AND DEVICES BEING CONTROLLED SHALL BE BY DIVISION 21 AND

SHALL BE IN CONFORMANCE TO DIVISION 26 REQUIREMENTS.

14. PROVIDE ANY ADDITIONAL DRAINS REQUIRED TO COMPLY WITH NFPA 13 AND LOCAL CODES (WITHOUT

ADDITIONAL COST TO OWNER).

15. PROVIDE A SINGLE AIR VENT WITH A CONNECTION CONFORMING TO NFPA 13-8.16.6 ON EACH WET PIPE

SYSTEM UTILIZING METALLIC PIPE.

16. PIPING: SPRINKLER PIPING SHALL BE SCHEDULE 40 STEEL PIPE AND COMPATIBLE FITTINGS IN

CONFORMANCE OF NFPA 13. MINIMUM SIZE IS ONE INCH. BRANCH LINES SHALL BE SCHEDULE 40 OR

EQUAL TO ALLIED X-L PIPE WITH THREADED FITTINGS OR THINWALL PIPES WITH WELDED OUTLETS AND

GROOVED FITTINGS. SCHEDULE 5 PIPE IS NOT ALLOWED. CROSS MAINS SHALL BE THINWALL PIPE WITH

GROOVED FITTINGS. ALL EXPOSED PIPING SHALL BE IN CONFORMANCE WITH ANSI A13.1.

17. SPRINKLERS SHALL BE QUICK RESPONSE TYPE, PENDENT, CONCEALED WITH WHITE COVER PLATE, VIKING

HORIZON MIRAGE OR APPROVED EQUIVALENT.

18. PIPE MATERIAL SHALL BE AS FOLLOWS: SHALL MEET NFPA-13 AND ASTM A795.

A. MINIMUM PIPE SCHEDULE FOR WELD/GROOVED/PLAIN BLACK STEEL PIPE SCHEDULE 10 OR

APPROVED EQUAL AS DYNAFLOW.

B. THREADED PIPE: BLACK STEEL, SCH 40.

C. FITTINGS: WELDED, SCREWED OR FLANGES 125#.

D. ALL DROPS SHALL BE 1" SCHEDULE 40, BLACK STEEL.

E. HANGERS SHALL BE THREADED CLAD PLATED, FITTINGS SHALL BE IN ACCORDANCE WITH NFPA-13.

19. DRAWINGS ARE SCHEMATIC ONLY AND DO NOT DEPICT EVERY DETAIL AND WORK REQUIRED FOR 100%

COMPLETION OF PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INCLUDE ALL WORK REQUIRED BUT

NOT SHOWN IN THE DRAWINGS TO COMPLETE THE WORK IN ACCORDANCE WITH ALL APPLICABLE CODES AND

RENDER FULLY OPERATIONAL. DO NOT SCALE THE DRAWINGS.

20. COORDINATE WITH ALL OTHER TRADES INVOLVED. ANY OFFSETS OR CHANGE IN DIRECTION REQUIRED

AROUND CONSTRUCTION SHALL BE INSTALLED AT NO ADDITIONAL COST TO OWNER.

21. ALL CUTTING AND PATCHING OF WALLS, FLOOR AND ROOF FOR FIRE PROTECTION WORK SHALL BE INCLUDED.

22. PROVIDE REQUIRED ACCESS TO ALL EQUIPMENT, EVEN IF NOT SHOWN IN THE DRAWINGS, FOR EASY

MAINTENANCE AND IN A LOCATION ACCEPTABLE TO A/E.

23. TEST FIRE SPRINKLER SYSTEM AT 200 PSI FOR 2 HOURS AND IN ACCORDANCE WITH NFPA 13.

24. USE UL LISTED FIRE STOPPING AT WALL PENETRATIONS.

25. PROVIDE SPARE SPRINKLER HEADS AND NECESSARY TOOLS TO REPLACE SPRINKLER HEADS IN AN

APPROVED CABINET AS REQUIRED BY NFPA 13.

26. A FLORIDA LICENSED SPRINKLER CONTRACTOR SHALL PROVIDE TWO COPIES EACH OF THE AUTOMATIC

SPRINKLER SYSTEM SHOP DRAWINGS CONTAINING; 1) SPRINKLER SYSTEM WORKING PLANS, INCLUDING

POINT OF SERVICE, SPRINKLER SYSTEM LAYOUT, NODE IDENTIFICATION AND NODE SPOT ELEVATIONS, 2)

WATER SUPPLY INFORMATION, 3) SPRINKLER SYSTEM DESIGN AND HYDRAULIC CALCULATIONS, INCLUDING

WATER SUPPLY CURVE AND SPRINKLER SYSTEM DEMAND, 4) HANGER DETAIL(S), AND 5) MANUFACTURER'S

TECHNICAL CUT SHEETS WITH SYSTEM COMPONENTS AND DEVICES IDENTIFIED.

27. SEE TSP'S FOR ADDITIONAL REQUIREMENTS

FINANCIAL PROJECT IDCOUNTYROAD NO.

WGI, INC.

3111 W. DR. MARTIN LUTHER KING JR. BLVD.

SUITE 375

TAMPA, FL 33607

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

T H E

O F F I C I A L

R E C O R D

O F

T H I S

S H E E T

I S

T H E

E L E C T R O N I C

F I L E

D I G I T A L L Y

S I G N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

ENGINEERING BUSINESS LICENSE NO.: 33574

G E N E R A L

D I S C L A I M E R T O

T H E

B E S T

O F

T H E

A R C H I T E C T 'S

O R

E N G I N E E R 'S

K N O W L E D G E T H E

P L A N S

A N D

S P E C I F I C A T I O N S

C O M P L Y

W I T H

T H E

A P P L I C A B L E

M I N I M U M

B U I L D I N G

C O D E S

A N D

T H E

A P P L I C A B L E

F I R E

S A F E T Y

S T A N D A R D S

A S

D E T E R M I N E D

B Y

T H E

L O C A L

A U T H O R I T Y

I N

A C C O R D A N C E

W I T H

F B C

.8 .4 .4

A N D

C H A P T E R

F L O R I D A

S T A T U E S

:5 :5

P M

A u to d e s k

D o c s .0

E C R C .0

E s c a m b ia

E C R C

W G

IM

E P F P

R .r v t

AF-001

FIRE PROTECTION GENERAL NOTES

ESCAMBIA 451524-1-38-01

NORTH W

STREET

STEPHEN R. FORKNER, PE

PE 80532

FIRE PROTECTION DRAWING INDEX

SHEET

NUMBER

SHEET NAME

AF-001 FIRE PROTECTION GENERAL NOTES

AF-101 OVERALL FIRE PROTECTION PLAN AND NARRATIVE

AF-501 FIRE PROTECTION DETAILS

SHEETS: 3

No. Date Issue / Revision

MECHANICAL

ELEC

FIRE

SUPPRESSION

151CONTROL

ROOM

RTMC

TRAINING/MEETING

ROOM

OFFICE

OFFICE

OFFICE

SERVER/BENCH

TEST

OFFICE

OFFICE

OFFICE

OFFICE

MEDIA

COVERAGE

ROOM

UPS

CORRIDOR

VESTIBULE

BREAK

ROOM

FOOD

STORAGE

FURNITURE

STORAGE

WOMEN

CHASE

MEN

FOOD

STORAGE

FAMILY

FAMILY

CORRIDOR

WET TYPE FIRE

PROTECTION SYSTEM

(UNHATCHED AREAS)

CLEAN AGENT AND PREACTION

SYSTEM COMPLETE WITH SMOKE

DETECTORS (HATCHED AREAS)

CLEAN AGENT AND

PREACTION SYSTEM

COMPLETE WITH SMOKE

DETECTORS (HATCHED

AREAS)

PREACTION

SYSTEM

COMPRESSOR

FP RISER

REFER TO CIVIL

DRAWINGS FOR

CONTINUATION

BREAK

ROOM

1 2

CLEAN AGENT

TANKS

TMC

STORAGE

OFFICE

105OFFICE

OFFICE

103OFFICE

OFFICE

FILE

STORAGE

AUTO

COLLABORATION

MEDIA

ROOM

CORRIDOR

120.3

NEXUS

CONFERENCE

MAIL /

SUPPLIES

DATA

VISUALIZATION

SPACE

115.1

DATA

VISUALIZATION

SUPPORT

115.2

JANITORIAL

UTILITY

110SUPPLIES

/ TECH

RESTROOM

RESTROOM

116 RESTROOM

DIGITAL

RECEPTION

COLLAB

OFFICE

COLLAB

OFFICE

COLLAB

OFFICE

CORRIDOR

FINANCIAL PROJECT IDCOUNTYROAD NO.

WGI, INC.

3111 W. DR. MARTIN LUTHER KING JR. BLVD.

SUITE 375

TAMPA, FL 33607

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

T H E

O F F I C I A L

R E C O R D

O F

T H I S

S H E E T

I S

T H E

E L E C T R O N I C

F I L E

D I G I T A L L Y

S I G N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

ENGINEERING BUSINESS LICENSE NO.: 33574

G E N E R A L

D I S C L A I M E R T O

T H E

B E S T

O F

T H E

A R C H I T E C T 'S

O R

E N G I N E E R 'S

K N O W L E D G E T H E

P L A N S

A N D

S P E C I F I C A T I O N S

C O M P L Y

W I T H

T H E

A P P L I C A B L E

M I N I M U M

B U I L D I

D E S

A N D

T H E

A P P L I C A B L E

F I R E

S A F E T Y

S T A N D A R D S

A S

D E T E R M I N E D

B Y

T H E

L O C A L

A U T H O R I T Y

I N

A C C O R D A N C E

W I T H

F B C

.8 .4 .4

A N D

C H A P T E R

F L O R I D A

S T A T U E S

:5 :5

P M

A u to d e s k

D o c s .0

E C R C .0

E s c a m b ia

E C R C

W G

IM

E P F P

R .r v t

AF-101OVERALL FIRE PROTECTION PLAN

AND NARRATIVE

ESCAMBIA 451524-1-38-01

NORTH W

STREET

STEPHEN R. FORKNER, PE

PE 80532

8'0' 32'16'

OVERALL FIRE PROTECTION PLAN

THE BUILDING WILL BE FULLY PROTECTED BY THE

FOLLOWING SYSTEMS:

THE ENTIRE BUILDING WILL BE PROTECTED BY A WET PIPE

SPRINKLER SYSTEM DESIGNED PER NFPA 13.

ALL STORAGE, MECHANICAL, ELECTRICAL, JANITORIAL, AND

COMMUNICATIONS AREAS SHALL BE DESIGNED TO ORDINARY

HAZARD (GROUP 1). THE SYSTEM HEAD LAYOUT SPACING WILL

NOT EXCEED 130 SQ. FT. PER SPRINKLER. DESIGN SHALL BE

BASED ON 0.15 GPM/SQ. FT. OVER 1,500 SQ. FT. VELOCITY

SHALL NOT EXCEED 20 FT. PER SECOND (FPS). PER THE

FDOT FACILITIES DESIGN MANUAL, ELECTRICAL ROOMS WILL

BE PROTECTED WITH AUTOMATICALLY OPERATING ON/OFF

FLOW CONTROL SPRINKLER HEADS. THESE HEADS WILL

FEATURE DUAL-THERMAL ELEMENTS WITH ON/OFF CONTROL

TO MINIMIZE WATER DAMAGE.

THE REMAINDER OF THE BUILDING WILL BE PROTECTED BY A

WET PIPE FIRE SPRINKLER SYSTEM FOR A LIGHT HAZARD

OCCUPANCY. THE SYSTEM HEAD LAYOUT SPACING WILL NOT

EXCEED 225 SQ. FT. PER HEAD. THE DESIGN SHALL BE

BASED ON 0.10 GPM PER SQ. FT. OVER 1,500 SQ. FT. WATER

VELOCITY SHALL NOT EXCEED 20 FPS.

THE UPS ROOM, AND THE SERVER / IT ROOM WILL BE

PROTECTED BY CLEAN AGENT GAS FIRE PROTECTION

SYSTEMS. THESE SPACES WILL ALSO BE PROTECTED WITH

PRE-ACTION SINGLE INTERLOCK SYSTEM.

COMBINATION WET AND DRY PIPE RISER DETAIL

NOT TO SCALE

S F

4" THICK

CONCRETE

RING

ESCUTCHEON LETTERING

"AUTO. SPKR."

2-1/2"x2-1/2"x4" F.D.C.(U.L./F.M.)

WITH ROUGH CHROME PLATED BODY

AND POLISHED CHROME TRIM.

LOCATION AND HOSE CONNECTION

TYPE SHALL BE APPROVED BY THE

LOCAL FIRE MARSHAL. REFER TO

DIV.02 DRAWINGS FOR LOCATION.

THRUST BLOCK

PER NFPA (TYP.)

4" FIRE DEPT.

CONNECTION

UNDERGROUND

6" TO DOUBLE CHECK BACK

FLOW PREVENTER, REFER TO CIVIL

DRAWINGS FOR CONTINUATION.

8" ABOVE

FINISHED GRADE

FINISHED GRADE

2" MAIN DRAIN

EXTERIOR WALL

PRESSURE GAUGE

4" WAFER

CHECK VALVE

PRESSURE GAUGE

4" O.S. & Y. CONTROL

VALVE WITH TAMPER

SWITCH. WIRE TO FIRE

ALARM BY OTHERS.

2" AGF TEST AND DRAIN WITH

PRESSURE GAUGE - MODEL

1011T OR EQUIVALENT

WATERFLOW SWITCH AND

WIRING

FIRE ALARM SPEAKER &

STROBE. SEE ELECTRICAL

DRAWINGS FOR REQUIREMENTS

4" ALARM VALVE

4" O.S. & Y. CONTROL

VALVE WITH TAMPER

SWITCH. WIRE TO FIRE

ALARM BY OTHERS.

BY DIV.21

BY CIVIL

A .F .F

6x4 REDUCER

DRY PIPE

WET PIPE

TO 1ST

FLOOR

SPACE

4 16

DRY PIPE RISER NOTES

1. DRY PIPE VALVE: DRY PIPE VALVE WITH RETARD CHAMBER,

PRESSURE SWITCH, LOW AIR ALARM, MAIN DRAINS, WATER

MOTOR GONG, AIR MAINTENANCE DEVICE AND QUICK

OPENING DEVICE. TYCO MODEL DPV-1 OR EQUIVALENT.

2. PRIMING CUP

3. LOCAL ALARM SWITCH OR ALARM TRANSMITTER

4. RESTRICTED ALARM VENT

5. AIR PRESSURE GAGE

6. DRIP CUP

7. ALARM TEST VALVE (NORMALLY CLOSED)

8. AUTOMATIC DRAIN VALVE

9. WATER PRESSURE GAGE

10. MAIN DRAIN ANGLE VALVE

11. DRIP CUP AND MAIN DRAIN DISCHARGE TO OUTSIDE OF BLDG.

(4'-0" - PIPE LENGTH

INSIDE OF BLDG.)

12. WATER MOTOR GONG

13. DRAIN RUN THROUGH WALL TO OUTSIDE OF BLDG.

14. COMPRESSED AIR LINE FROM AIR COMPRESSOR. REFER TO PLAN

FOR LOCATION. SYSTEM SHALL HAVE ADEQUATE CAPACITY TO

RESTORE NORMAL AIR PRESSURE IN THE DRY PIPE SYSTEM

WITHIN 30 MINUTES. PROVIDE FLANGED INCREASERS /

REDUCERS TO ADAPT PIPE SIZE TO VALVE SIZE.

15. OS & Y VALVE WITH TAMPER SWITCH. WIRE TO FIRE ALARM BY

OTHERS.

16. CHECK VALVE TO PREVENT TRIPPING VALVE WHEN TESTING

ALARM

17. AIR LINE CHECK VALVE

18. AIR SUPPLY GLOBE VALVE (RENEWABLE DISC TYPE)

19. PRESSURE RELIEF VALVE 20.

20. AIR SUPPLY LINE

21. ELECTRIC LOW AIR PRESSURE ALARM TRANSMITTER

22. ALARM CONTROL VALVE (NORMALLY OPEN)

23. STRAINER

24. DRAIN GLOBE VALVE

25. PRIMING VALVE (NORMALLY CLOSED).

FOUNDATION PIPE SLEEVE DETAIL

NOT TO SCALE

CAST IRON CARRIER PIPE SLEEVE TO

EXTEND 12" (MIN.) OUTSIDE CONE OF

INFLUENCE WHERE PENETRATION IS MADE

BELOW FOOTING. CARRIER SLEEVE TO BE A

MINIMUM OF TWO PIPE SIZES LARGER THAN

THE LINE SIZE

FOUNDATION WALL

PIPING SHALL NOT BE

RUN THROUGH FOOTINGS

FOOTING

COMPACTED BACK FILL

CONE OF INFLUENCE 45°

OUTWARD FROM BOTTOM

OF FOUNDATION FOOTING

FIRE PROTECTION PIPING

BELOW FOOTING

SEAL VOID BETWEEN

WASTE LINE AND SLEEVE

WITH ROOM TEMPERATURE

VULCANISING (RTV) FOAM AT

EACH END

FINANCIAL PROJECT IDCOUNTYROAD NO.

WGI, INC.

3111 W. DR. MARTIN LUTHER KING JR. BLVD.

SUITE 375

TAMPA, FL 33607

DWG NO.

SHEET NO.

FLORIDA-ALABAMA TPO

T H E

O F F I C I A L

R E C O R D

O F

T H I S

S H E E T

I S

T H E

E L E C T R O N I C

F I L E

D I G I T A L L Y

S I G N E D

A N D

S E A L E D

U N D E R

R U L E

G .0 F .A .C

ENGINEERING BUSINESS LICENSE NO.: 33574

G E N E R A L

D I S C L A I M E R T O

T H E

B E S T

O F

T H E

A R C H I T E C T 'S

O R

E N G I N E E R 'S

K N O W L E D G E T H E

P L A N S

A N D

S P E C I F I C A T I O N S

C O M P L Y

W I T H

T H E

A P P L I C A B L E

M I N I M U M

B U I L D I

D E S

A N D

T H E

A P P L I C A B L E

F I R E

S A F E T Y

S T A N D A R D S

A S

D E T E R M I N E D

B Y

T H E

L O C A L

A U T H O R I T Y

I N

A C C O R D A N C E

W I T H

F B C

.8 .4 .4

A N D

C H A P T E R

F L O R I D A

S T A T U E S

:5 :5

P M

A u to d e s k

D o c s .0

E C R C .0

E s c a m b ia

E C R C

W G

IM

E P F P

R .r v t

AF-501

FIRE PROTECTION DETAILS

ESCAMBIA 451524-1-38-01

NORTH W

STREET

STEPHEN R. FORKNER, PE

PE 80532

Sheets
AF-001 - FIRE PROTECTION GENERAL NOTES
AF-101 - OVERALL FIRE PROTECTION PLAN AND NARRATIVE
AF-501 - FIRE PROTECTION DETAILS
2025-04-01T07:55:22-0400
Stephen R Forkner
2025-04-01T07:55:44-0400
Stephen R Forkner
2025-04-01T07:56:13-0400
Stephen R Forkner

File details come from the government source that posted it. Updated .