4. Attachment D tab - Facility Specifications Clean Room Specifications List.pdf
PDF 194 KB Posted
- Attached to
- NASA GRC Custodial Services
- Solicitation number
- 80GRC025R7004
About this file
This is a clean room specifications list (Attachment D) for NASA Glenn Research Center's custodial services contract. The document details specifications for 16 clean rooms across Buildings 77, 110, 301, and 333, including their ISO 14644-1 and Federal Standard 209B classifications, dimensions, and cleaning requirements. The clean rooms range from ISO Class 2 (Fed. Std. 100) to ISO Class 5 (Fed. Std. 100,000), with room dimensions varying significantly from small spaces like 12' x 12' to large areas such as 60' x 72'.
Most rooms require active daily service, with specific timing requirements noted for certain facilities (e.g., evenings OK or daytime between 5:30-7:00 a.m. for Building 110). Some rooms are cleaned upon request (IDIQ basis). The document notes that specifications should be considered reasonably accurate but may change due to ongoing construction and building rehabilitation projects. The government does not expect to make cost adjustments unless changes are substantial, such as long-term building closures or new facility construction.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment D
Bldg. # Room #
ISO 14644-
1 Clean Fed. Std. 209B
Clean Room Dimensions Comments/Status Period for Cleaning
77 18 4 10,000 12 X 12 X 8 Clean upon request IDIQ. None specified
77 308 4 10,000 9 X 18 X 8 Active, 1 hr. per week for floors; 4 hrs per month for walls Daytime only
77 310 5 100,000
21 X 7.5 X
36 X 5 X 8 Active, 1 hr. per week for floors; 4 hrs per month for walls Daytime only
77 311 2 100 52 X 20 X 8 Active, daily service (1 hr.) None specified
77 312 4 10,000 17 X 18 X 8 Active, 1 hr. per week for floors; 4 hrs per month for walls None specified
77 320 3 1,000 20 X 64 X 8 Active, daily service. None specified 77 321 2 100 17 X 32 X 8 Active, daily service. None specified
110 3 3 to 5 1,000 - 100,000 25 X 18 X 8 Active, daily service.
Evenings OK or daytime between 5:30 - 7:00 a.m.
110 126 5 100,000 50 X 76 X
28 Active, daily service.
Evenings OK or daytime between 5:30 -
7:00 a.m.
110 127 5 100,000 25 X 29 X
10 Active, daily service.
Evenings OK or daytime between 5:30 -
7:00 a.m.
110 128 5 100,000 20 X 29 X
10 Active, daily service.
Evenings OK or daytime between 5:30 -
7:00 a.m.
110 129 5 100,000 20 X 29 X
10 Active, daily service.
Evenings OK or daytime between 5:30 -
7:00 a.m.
301 252 2 to 3 100 to 1,000 13 X 22 X 9 Clean upon request IDIQ. Second shift OK but w/key
333 100E 5 100,000 60 X 72 X
70 Active, daily service.
Evenings OK or daytime between 5:30 -
7:00 a.m.
NASA Glenn Research Center List of Clean Rooms
The information contained in this document should be considered reasonably accurate. Details related to square footage, quantities, flooring types, window types, etc are all affected by ongoing construction and building rehabilitation projects. These types of changes may not be reflected in this document and will continue throughout the term of the contract. The Government does not expect to make any cost adjustments as a result of errors in this document or due to the ongoing changes unless the changes are substantial. Long term or permanent building closures and new facility construction would represent substantial changes.
Clean Rooms D1
333 100W 5 100,000 3 X 125 X 65* Active, daily service.
Evenings OK or daytime between 5:30 -
7:00 a.m.
Lab C;
100W 5 100,000 12 X 33 X 8 Active, daily service.
Evenings OK or daytime between 5:30 - 7:00 a.m.
* Room 100 West is a large room housing three labs, A, B and C in addition to the surrounding Clean Room area. Labs A and B are not Clean Rooms, but Lab C is listed separately above.
Clean Rooms D2
Clean Rooms D3
Clean Rooms