4. Attachment D tab - Facility Specifications Clean Room Specifications List.pdf

PDF 194 KB Posted

Attached to
NASA GRC Custodial Services
Solicitation number
80GRC025R7004
Issued by

About this file

This is a clean room specifications list (Attachment D) for NASA Glenn Research Center's custodial services contract. The document details specifications for 16 clean rooms across Buildings 77, 110, 301, and 333, including their ISO 14644-1 and Federal Standard 209B classifications, dimensions, and cleaning requirements. The clean rooms range from ISO Class 2 (Fed. Std. 100) to ISO Class 5 (Fed. Std. 100,000), with room dimensions varying significantly from small spaces like 12' x 12' to large areas such as 60' x 72'.

Most rooms require active daily service, with specific timing requirements noted for certain facilities (e.g., evenings OK or daytime between 5:30-7:00 a.m. for Building 110). Some rooms are cleaned upon request (IDIQ basis). The document notes that specifications should be considered reasonably accurate but may change due to ongoing construction and building rehabilitation projects. The government does not expect to make cost adjustments unless changes are substantial, such as long-term building closures or new facility construction.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment D

Bldg. # Room #

ISO 14644-

1 Clean Fed. Std. 209B

Clean Room Dimensions Comments/Status Period for Cleaning

77 18 4 10,000 12 X 12 X 8 Clean upon request IDIQ. None specified

77 308 4 10,000 9 X 18 X 8 Active, 1 hr. per week for floors; 4 hrs per month for walls Daytime only

77 310 5 100,000

21 X 7.5 X

36 X 5 X 8 Active, 1 hr. per week for floors; 4 hrs per month for walls Daytime only

77 311 2 100 52 X 20 X 8 Active, daily service (1 hr.) None specified

77 312 4 10,000 17 X 18 X 8 Active, 1 hr. per week for floors; 4 hrs per month for walls None specified

77 320 3 1,000 20 X 64 X 8 Active, daily service. None specified 77 321 2 100 17 X 32 X 8 Active, daily service. None specified

110 3 3 to 5 1,000 - 100,000 25 X 18 X 8 Active, daily service.

Evenings OK or daytime between 5:30 - 7:00 a.m.

110 126 5 100,000 50 X 76 X

28 Active, daily service.

Evenings OK or daytime between 5:30 -

7:00 a.m.

110 127 5 100,000 25 X 29 X

10 Active, daily service.

Evenings OK or daytime between 5:30 -

7:00 a.m.

110 128 5 100,000 20 X 29 X

10 Active, daily service.

Evenings OK or daytime between 5:30 -

7:00 a.m.

110 129 5 100,000 20 X 29 X

10 Active, daily service.

Evenings OK or daytime between 5:30 -

7:00 a.m.

301 252 2 to 3 100 to 1,000 13 X 22 X 9 Clean upon request IDIQ. Second shift OK but w/key

333 100E 5 100,000 60 X 72 X

70 Active, daily service.

Evenings OK or daytime between 5:30 -

7:00 a.m.

NASA Glenn Research Center List of Clean Rooms

The information contained in this document should be considered reasonably accurate. Details related to square footage, quantities, flooring types, window types, etc are all affected by ongoing construction and building rehabilitation projects. These types of changes may not be reflected in this document and will continue throughout the term of the contract. The Government does not expect to make any cost adjustments as a result of errors in this document or due to the ongoing changes unless the changes are substantial. Long term or permanent building closures and new facility construction would represent substantial changes.

Clean Rooms D1

333 100W 5 100,000 3 X 125 X 65* Active, daily service.

Evenings OK or daytime between 5:30 -

7:00 a.m.

Lab C;

100W 5 100,000 12 X 33 X 8 Active, daily service.

Evenings OK or daytime between 5:30 - 7:00 a.m.

* Room 100 West is a large room housing three labs, A, B and C in addition to the surrounding Clean Room area. Labs A and B are not Clean Rooms, but Lab C is listed separately above.

Clean Rooms D2

Clean Rooms D3

Clean Rooms