This is a technical standards document issued by the City of Detroit Department of Innovation and Technology (DoIT) that establishes mandatory requirements for structured cabling and security system infrastructure across all City of Detroit facilities. The standards apply to the complete lifecycle of DoIT support infrastructure, encompassing planning, design, construction, operation, maintenance, repair, and modernization activities. The document specifies technical requirements for information transport systems, IT equipment and systems, telecommunications spaces and equipment, physical security systems including surveillance cameras and access control devices, and supporting infrastructure such as power distribution and environmental conditioning systems. All materials must be new and comply with standards established by recognized authorities including ANSI, ASTM, BICSI, IEEE, NEC, NEMA, TIA, UL, and NFPA.
The standards mandate CAT6E plenum cabling with specific approved vendors including Hubbell, Superior-Essex, Leviton-BerkTek, Belden, and CommScope. Patch cable color codes are standardized by location type: purple for Central City sites, blue for Public Safety sites, and green for wireless and security systems. The City exclusively uses AXIS cameras (P, Q, and select M series) integrated with the Genetec video management system version 5.10.2129.0, with no alternative security systems permitted on the CoD network. All security vendors must be Genetec Elite certified channel partners, and all personnel working on CoD security and network systems must be fingerprinted, background checked by Detroit Police Department, and possess Michigan State Police CJIS security awareness training. The document includes detailed specifications for video surveillance design, access control systems using Mercury LP series door controllers, intrusion detection systems using Bosch B9512G panels, cabling management practices, labeling conventions, network testing requirements utilizing TIA/ISO certified devices, and comprehensive closeout documentation requirements including as-builts, hardware inventories, and system test reports. All projects must obtain appropriate low voltage and electrical permits and pass inspections from the City of Detroit Buildings, Safety, Engineering, and Environmental Department prior to completion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Structured Cabling and Security System Standards 1
THE CITY OF DETROIT
DEPARTMENT OF INNOVATION AND TECHNOLOGY
STANDARDS FOR INFRASTRUCTURE AND EQUIPMENT
Structured Cabling and Security System Standards 2
PURPOSE
This document is designed to serve as the CoD (City of Detroit) standards for network and security systems. The objectives below defined by the Department of innovation and Technology set the expectations and requirements for network and security systems deployed within the City of Detroit.
The DoIT Network Structured Cabling and Security System Standards (The Standards) serves as the master reference document of criteria for City of Detroit Department of Innovation and Technology.
All teams that are responsible for engineering, delivery, and operations of network services that need to identify or classify a network device must comply with this standard.
This document defines the technical requirements necessary to maintain optimum reliability and efficiency within a CoD facilities and computing centers.
To create a meaningful and well understood cross team standard for naming network devices throughout the City of Detroit /DoIT network.
Offer guidance on how to design video surveillance systems and access control systems that meet CoD specifications.
Provide a set of best practices and standards to be followed during the system implementation to ensure consistency, reliability, and security
Outline technical and functional standards for various security components and systems, such to ensure they are up to CoD specifications.
Lay out the requirements for video surveillance, access control and intrusion detection systems to maintain secure and controlled access to facilities and protect against unauthorized entry or activities.
Dictate the methods of network and system testing to maintain system integrity, performance, and security.
Outline the necessary permits and inspections required by law or policy, ensuring that all systems meet legal and safety codes.
Address Exceptions: Provide a protocol for handling exceptions to the standards, allowing for flexibility under certain conditions while maintaining overall security posture.
Structured Cabling and Security System Standards 3
SCOPE
The Standards will be applied to the entire lifecycle of DoIT support infrastructure within every City of Detroit Facility. This includes, but is not limited to, planning, design, construction, operating, maintaining, repairing, restoring and modernization as well as the administrative activities that support these processes.
CoD supported infrastructure is defined as all passive telecommunications and information technology equipment, and supporting physical space and equipment, supporting:
• Information Transport Systems (ITS), including copper and fiber optic cabling.
• IT equipment and systems, such as servers, storage, network switches, and distribution hardware.
• Telecommunications spaces, which involve telecommunications rooms, entrance facilities, datacenters, and both horizontal and vertical distribution pathways.
• Telecommunications equipment and systems (local and wide area network, telephone, cable television, etc.)
• Physical security systems, including surveillance cameras, access control devices, intrusion detection systems, Video management systems (VMS), and other related security infrastructure.
• The physical infrastructure equipment and systems necessary to support the operations of active equipment, ensuring the required levels of availability and sustainability. Such infrastructure includes power and power distribution units (PDU), environmental conditioning and monitoring and bonding and grounding systems.
Structured Cabling and Security System Standards 4
MATERIALS AND QUALITY OF WORK
All materials shall be new, never used, reused, reconditioned, or refurbished components. The electrical and physical properties of all materials, and the design, performance characteristics, and methods of construction of all items of equipment, shall be in accordance with the latest issue of the various, applicable Standard Specifications of the following recognized authorities:
• A.N.S.I. American National Standards Institute
• A.S.T.M. American Society for Testing Materials
• BICSI Building Industry Consulting Services International
• I.C.E.A. Insulated Cable Engineer’s Association
• I.E.E.E. Institute of Electrical and Electronics Engineers
• N.E.C. National Electrical Code
• N.E.M.A. National Electrical Manufacturer's Association
• TIA Telecommunications Industry Association
• U.L. Underwriters Laboratories, Inc. NFPA National Fire Protection Agency
Structured Cabling and Security System Standards 5
STRUCTURED CABLING STANDARDS
CAT6 STRUTURED CABLING SYSTEM PRODUCTS
Current cabling standard for all installations is CAT6E (Plenum)
Any one of the following CAT6E structured cabling system products are acceptable
• Hubbell NEXTSPEED Cat 6 enhanced
• Superior-Essex NextGainCat6EX
• Leviton-BerkTek Lanmark-2000
• Belden Cat6e+ Premium 3613
• CommScope Uniprise CS37P Cat6E
PATCH CABLE COLOR CODE REQUIREMENTS (Patch panel and drop)
• Central City Sites – Central City patch cables are Purple
• Public Safety Sites – Public Safety patch cables are Blue
Wireless and Security (cameras, door access) patch cables are Green
• Fax lines and analog phone lines – White
FIBER CABLING REQUIREMENTS
Multimode, 50 micron, OM4, LC-to-LC (unless otherwise specified)
NETWORK RACK REQUIREMENTS (based on specific job requirements)
2-Post
Panduit (2-post): Part #R2PW
• Panduit PR2V Vertical Dual-Sided Manager: Part #PR2VD06 (optional, based on job)
Enclosed (Wall Mount)
SysRack 12U 24″ Depth Wall Mount 19″ Enclosure SRW 12.600
Enclosed (Cabinet)
SysRack T32U 24″ Depth IT & Telecom Cabinet SRF 32.6.6
AT&T WAN CIRCUIT REQUIREMENTS
In situations where a AT&T WAN circuit is being installed, the following items are required to be installed
• A minimum 4' x 4' x ¾" fire-rated plywood backboard
• 110v NEMA 5-15R, 15 Amp 3-prong electrical outlet. A dedicated outlet is required to ensure the draw of electrical current not overload your system, blow a fuse, or trip a
Structured Cabling and Security System Standards 6 circuit breaker. The circuit must accommodate for a maximum of 95 Watts. Use of extension cords is not permitted.
• A new #6 ground wire bonded to an MGN or UFER Ground terminated to a Grounding bus bar
Structured Cabling and Security System Standards 7
MANAGEMENT OF TELECOMMUNICATIONS CABLING
Proper cable management is necessary to enable optimal airflow through IT equipment (minimizing energy usage), to allow identification and management of cabling throughout the IT equipment lifecycle, and to minimize risks of damage to the networking system by minimizing opportunities for damage to cables, connectors, and conveyances.
EVALUATION FACTORS
Cable management allows appropriate airflow
Cables properly labeled to allow easy identification
Cable management is organized, logical, systematic, and aesthetic
IMPLEMENTATION REQUIREMENTS
Cable that is installed above a suspended ceiling must be supported per NFPA code requirements. Three choices are, conduits, cable tray or by J-hooks.
Cabling plants shall be planned to enable the installation of IT equipment. Install and utilize cable conveyances (cable trays, cable managers, and similar) in all IT installations.
Free-run telecommunications cabling is NOT maintainable or sustainable and has a higher lifecycle cost than properly designed and installed cabling plant systems.
Cabling shall be run in horizontal, vertical, or overhead cable management systems where available. Procure and install cable management equipment when cabling installations need such to enable aesthetic, managed cabling outcomes.
Always plan the cabling path and manage the cabling installation, down to the level of the patch cable to the individual piece of IT equipment. Individual cables shall not be free run.
Individual cable lengths shall be selected appropriately for their purpose. Cable slack shall be managed with attention to installation criteria such as bend radius. Excessive slack indicates a poor choice of cable length.
Patch cables and power cords between Rack PDUs and IT equipment shall not be run from one IT equipment rack to another. Power distribution detailed in the infrastructure section specifically calls out zone PDUs that supply power to multiple racks to obtain maximum power densities. These devices and their power supplies are not affected by this guidance.
Patch and power cables shall not be left unmanaged where they may interfere with exhaust airflow or have the potential to catch or snag on people or equipment.
Document all cabling components and their linkage between components and make sure that this information is updated on a regular basis. The installation, labeling, and documentation should always match. Maintain cabling documentation, labeling, and logical/physical cabling diagrams.
Structured Cabling and Security System Standards 8
EXAMPLES OF PROPER AND IMPROPER INSTALLATION
These are examples of acceptable cabling management implementations.
Proper management of patch cables with the use of horizontal and vertical wire managers Properly dressed and labeled cables in a ceiling hung cable tray
Properly dressed and organized cables in a server cabinet. Airflow is not obstructed, and cables are secured as to prevent damage
Cabling is carefully run as to not interfere with the sliding motion of the server or server cabling
Ethernet patch cables neatly organized and labeled evenly and in-line with machine printed labels Properly dressed cables in a ceiling mounted cable tray.
Structured Cabling and Security System Standards 9
Consider vendor-specific IT equipment requirements for cabling so as not to impede intended operation of that equipment, such as blocking exhaust ports. The cabling management in Image 1 is appropriate except for the aqua-colored cables entering from the left, which cover the fan module on the left of the switch. This keeps the fan module from being replaced without disconnecting the network.
Aqua colored cables on the left are improperly installed as they prevent the removal of the fan module
Structured Cabling and Security System Standards 10
INSTALLATION STANDARDS
Comply with latest editions and addenda of TIA-568 (SET) (cabling), TIA-569 (pathways), TIA-607 (grounding and bonding), BICSI N1, NFPA 70
Copper Clad Aluminum (CCA) twisted pair communication cable is strictly forbidden
All cabling shall be installed in a neat, workman like manner without twists, kinks, and unnecessary crossovers
Cables should not be in contact with the ground. Use cable management components and techniques to maintain a clean, clear, and safe work environment
Do not mount cabling in locations that block access to other equipment (e.g., power strip or fans) inside and outside the racks
Patch cables should follow the side of the IT equipment rack closest to the assigned NIC
Cables should not be looped around themselves or other objects
Route cables with gentle loops to avoid damage due to exceeding bend radius limitations. Glass fiber can be easily broken with rough handling or overly tight bends
Cables should be tight enough to maintain position but not tight enough to deform the jacket or put tension on the connectors
Based on heat exhaust (airflow), serviceability, and excess cable lengths, do not install folding/retractable cable management arms for IT equipment in computer spaces. Arms currently installed on existing equipment may be used until the equipment is refreshed and removed. · All cable slack should be concealed within the rack either vertically or within cable managers. Slack should not be looped. With use of the correct length cables, there should not be sufficient slack to enable looping. · Use the correct length patch cables. Cables should not be twisted or wrapped around other cables, including when bundled
Structured Cabling and Security System Standards 11
NETWORK CABLE BUNDLING
Bundle cables together in groups of relevance (for example, cables to a single equipment distributor or uplinks to core devices), as this will ease management and troubleshooting.
Bundles of cables, when necessary, should be built from sub-bundles of no more than 16 individual cables. The larger bundles should not exceed 4 sub-bundles of like quantity.
When bundling or securing cables, use Velcro-based ties not more than every 1 to 2 meters, and more frequently as needed to maintain a clean installation. Do not use zip ties or twist ties for cable bundling or securing, as these apply pressure on the cables.
Only bundle like cable types. Do not bundle fiber, power, and UTP together.
Cable labels shall be visually accessible to local personnel following installation, for future Identification and troubleshooting purposes. Rather than bundling groups of cabling in a manner that prevents identification of individual cables, bundle in a different manner and/or relocate the cabling to locations where they will not be obscured. Consider bundling so all cables are on the exterior of the bundle.
Structured Cabling and Security System Standards 12
UTP, FIBER, POWER CABLING
Segregate power and telecommunications cabling in separate cable tray systems; use different conveyance systems located not less than 12” apart when these two systems are run in parallel.
Where possible, run power and telecommunications in separate paths to reduce risks of EMI/RFI and data transmission losses.
Do not install UTP cabling on top of fiber cabling to prevent damage to the fiber transmission medium.
Segregate UTP and fiber telecommunications cabling, using different conveyances where possible. Where not possible or provided, ensure fiber cable is protected from damage. Use fiber inner duct where necessary within the same cabling conveyance.
Use properly sized equipment power cords; use of 6’ length power cords where 2’ cords are needed is not considered a best practice.
Separate A- and B-side power and segregate equipment power cords (between vertical rack power distribution units and IT equipment) by color for identification of A/B power to each piece of IT equipment.
CABLE LABELING
The CoD standard specifies use of ANSI/TIA 606-C compatible formats for identifying data communications cabling. More complicated installations may require reference to that document. Data communications cabling (UTP, fiber, and others) shall be labeled on both ends with information (6-digit drop ID) about the network port that it connects to on each end. Machine-printed tags secured with clear plastic or acetate adhesive tape are the minimum standard for these tags as in Figure below. Handwritten labels of any type are NOT permitted.
To identify the connected path of each data communications cable, the physical position identifiers at both ends of the cable are needed. The label for each end of the cable shall identify the six-digit drop ID as described on the next page/section of this document (Drop and Patch Panel Labeling)
Structured Cabling and Security System Standards 13
DROP AND PATCH PANEL LABELING
All installed drops must be labeled and must correspond to patch panel labeling precisely according to the following specifications:
Patch panels should be labeled per the following specification: Each patch panel should be represented by a 3-digit alphanumeric patch panel ID label (e.g. 11A,21B, 31C) where the first numeric character represents the floor where the IDF/MDF exists (0 for basement, 1 for the first floor, 2 for the second floor, etc.) and the second numeric character represents the IDF number per floor. The third character is the unique letter designation for each patch panel beginning with “A”. For example: The second of two IDFs on the first floor would have its patch panels labeled 12A, 12B, 12C and so forth. The actual patch panel ports should be labeled 001, 002, 003 and so on. Each patch panel port label should begin at 001 and end at 048 (48-port patch panel).
Drops ( jacks) should be labeled per the following specification: The drop ID is a 6-digit alphanumeric convention where the first three digits are the patch panel ID as explained in the patch panel labeling specification above, and the last three digits are numeric and represent the actual drop number using the following format (001, 002, 036, 042 and so on). Drop ID numbers should match patch panel numbering.
Drop ID examples: Drop with 12A022 would indicate that the drop is terminating to the second of two IDFs on the 1st floor, patch panel A, and patch panel port (22) 022. In another example, drop 21C010 would indicate that the drop is terminated to an IDF on the 2nd floor, patch panel C, and patch panel port (10) 010. Note: Basement floors are denoted with a “0”.
FIRST DIGIT SECOND DIGIT THIRD DIGIT LAST 3 DIGITS
Floor MDF/IDF Patch Panel Drop Number
1 2 A 022
2 1 C 010
0 1 B 003
Structured Cabling and Security System Standards 14
Patch Panel and Drop Labeling Illustrated: Note: Patch panel ports must be labeled as shown below according to the 3-digit drop ID number. Patch panel port numbering should start at 001 and end at 024 or 048 (depending on patch panel size) for each patch panel installed.
The first 3 digits of the of the drop ID must be labeled on the left side of each patch panel installed as shown here
Drop (Jack) labeling illustrated:
Structured Cabling and Security System Standards 15
PATCH PANEL TYPES
Fixed form factor patch panels required. Do use modular (keystone) type patch panels.
Preferred patch panel brands include Panduit, Ortronics, Black Box, Leviton, Tripp Lite, and
Hubbell
Structured Cabling and Security System Standards 16
SECURITY VENDORS
COMPANY REQUIREMENTS
The company installing cameras, access control, intrusion detection or any other device connecting to the City of Detroit Genetec system must be a Genetec certified channel partner. Elite Certification or better is preferred.
Companies not Genetec certified may not sub-out to Genetec certified companies.
The company needs to have current certifications for the security hardware they are installing and must be able to create support requests as needed with manufacture for all components being provided.
EMPLOYEE REQUIREMENTS
The individual programming the Genetec system must have a Genetec Omnicast and Synergis Certificate for video/access control
All individuals working on any CoD Security and Network systems must be fingerprinted and background checked by the Detroit Police Department and have Michigan state police CJIS security awareness training on file.
Proof of clearance and certifications shall be provided prior to starting work
Structured Cabling and Security System Standards 17
SECURITY SYSTEM DESIGN GUIDELINES
GUIDELINES FOR VIDEO SURVEILLANCE DESIGN
The following areas should be considered for coverage when designing a video surveillance system
Building Ingress and egress areas
Exterior perimeter of building and approaches
Doors controlled by access control systems
Elevator lobbies
Stairwells
Money handling or mail areas
Front desk/customer interaction areas
Special needs areas
Areas where high value items are stored
Rooms containing security system servers, access control systems, and intrusion systems controllers.
IDF/MDF rooms where network switches are located
Emergency call box locations
GUIDELINES FOR ACCESS CONTROL SYSTEM DESIGN
It is recommended the following areas be outfitted with access control doors as budget permits
Perimeter doors high security areas restricted access rooms inventory and storage rooms
MDF and IDF rooms
Magnetic locking mechanism should be avoided whenever possible
GUIDELINES FOR VIDEO INTRUSION DESIGN
Intrusion points should include sensors on exterior doors and entry points motion detection on main entry points, 1st floor halls and corridors, rooms with windows reachable from the exterior, areas with valuables glass break sensors should be installed in areas with significant glass
Structured Cabling and Security System Standards 18
SYSTEM IMPLEMENTATION REQUIREMENTS
All security designs and installations must be reviewed and approved by DoIT PS prior to procurement and installation.
All security system design and hardware submittals are approved by DoIT PS
Project kickoff includes communication plan involving all stakeholders
Prior to commencement of work, city project manager to coordinate activities and access to site, contractor, city project manager, DoIT network and DoIT PS must conduct mandatory job walk
CoD will validate all camera views. The camera aiming process must be coordinated and collaborated with the CoD
Existing installations, if the addition of new devices cause more that 80% of the open ports on the switch to be used, a new switch must be purchased.
Switch make and model to be approved by DoIT Network team
Programming shall not start until Genetec licenses for the project are purchased and loaded into the CoD Genetec system
Vendor laptops are not allowed to be plugged into CoD network Switches. All Genetec programming must occur through the CoD Securelink system. Camera programming must occur through SecureLink via the on-site archiver or via standalone vendor supplied network / POE hardware.
After a site is commissioned and handed over to the customer, all vendor access and entry to the site must be scheduled and coordinated with DoIT
Structured Cabling and Security System Standards 19
VMS
GENETEC VMS SYSTEM STANDARDS
The CoD uses Genetec as its enterprise security system. No other type of security systems is allowed to be installed on the CoD network.
The CoD requires all security systems to be installed as an expansion to the current system.
All installed expansion instances of the Genetec server software must be version 5.10.2129.0
Locations with surveillance cameras shall have a Genetec Streamvault archiver installed on site.
Streamvault SV350 or larger are allowed. SV300s are not allowed.
Archiver shall support 30 days of continuous recording video on all cameras using CoD supplied cameras settings
Archiver primary video storage shall be configured in a redundant RAID configuration
Archiver must be rack mounted and locked in cabinet
Non-rackmount archivers shall be provided with official genetec rack mounting accessories
Archiver shall include rackmount KVM
Archiver shall have a remote management NIC (iDrac or iLO). Remote management system shall be confirmed as per DoIT specifications.
Archiver shall be protected by UPS. Model of UPS to be confirmed by DoIT
Archiver UPS shall be connected to network for monitoring, programmed with IP provided by DoIT
CoD camera settings will be supplied at the start of project
Whenever a camera is in view of a door that is access controlled. That camera shall be associated with that door
Whenever possible, a drawing of the building shall be entered into Genetec maps, and the appropriate doors and cameras overlaid onto that map
Structured Cabling and Security System Standards 20
SECURITY CAMERAS
SECURITY CAMERA STANDARDS
The CoD uses AXIS Cameras exclusively for video surveillance. Any other types of video surveillance cameras are not allowed to be installed unless explicitly allowed by DoIT
All camera models must be certified to work on Genetec version 10.5.2
AXIS Cameras shall be P or Q series. M series for fisheyes style cameras only.
Refer to section x.x “APPROVED HARDWARD SPECIFICATIONS”
Allowed M series cameras: M43
Allowed P series cameras: P13, P14, P32, P373x, P38, P47
Allowed Q series cameras: Q16, Q17, Q35, Q36, Q60-63, Q87
Any variations to the above must be approved by DoIT PS
AXIS Cameras shall have advanced object detection
Cameras are mounted with AXIS compatible mounting systems.
Cable penetrations into the camera body utilize the AXIS supplied cable gaskets. Gaskets must be installed and in good condition.
Network camera drops are terminated at the camera side into a labeled jack
Network cameras shall be connected to the jack with vendor supplied green patch cord
Camera installation does not occur until construction activities have completed (drywall, painting)
All cameras mounted to a drop ceiling are to be secured with a solid support within or above the tile. No direct mounting to ceiling tiles is allowed
IP based door intercoms must be compatible with Genetec
All cameras must be labeled with an electronically printed label, The label shall be black on white for white cameras and be 1” inch tape height. The label text shall match what is provided by the DoIT hardware sheet
Structured Cabling and Security System Standards 21
ACCESS CONTROL
ACCESS CONTROL SYSTEM REQUIREMENTS
All card readers deployed must support PROX, iClass, and Bluetooth technologies
Door controllers, readers, operators, sensors and accessories must be secured with a reliable source of emergency power to guarantee functionality during any power interruption scenarios
Door controllers shall be centralized to the building or floor, not installed at door location unless authorized by DoIT
All door controller units shall be Mercury LP series and MR series 3 boards
Each location utilizing mercury door controllers should have 1 Genetec cloudlink installed on site.
When the current demand for the door hardware exceeds the capacity of the door controller, an auxiliary power relay shall drive the door hardware.
HID EDGE EVO controllers are not allowed
All doors shall have an unlocking device, REX, and door contact (door sensor)
2N Card readers are not allowed
If required per code, the access control system shall interface with the fire alarm system to ensure in the event of fire alarm activation of system failure access-controlled egress doors are released to allow unobstructed exit.
All cabling used for connecting door controller hardware to controllers shall be composite in nature, combining power, data, and other functions in a single sheath.
All exposed cabling shall be routed withing conduit to provide against physical damage, Communication and equipment room cabling shall be routed within conduit, slotted cable duct, or coverable cable raceways.
Access control cabling shall be organized neatly and tidily to facilitate east identification, maintenance, and troubleshooting. All cables shall be supported, dressed, and labeled.
Structured Cabling and Security System Standards 22
INTRUSION DETECTION
INTRUSION DETECTION SYSTEM REQUIREMENTS
Intrusion detection panel shall be Bosch model B9512G unless otherwise approved by DoIT
Panel and all accessories must be powered by backup batteries in the case of primary power loss
Network connectivity via CAT6 cable that is run to the panel enclosure and terminated at a labeled keystone.
Each Motion detector, glass break sensor, and door and window contacts are addressed as unique points
Intrusion system can detect physical tampering, including opening of the panel enclosure.
System is integrated into the CoD Genetec system, appropriate licenses are purchased to do so.
User pin codes are synced to Genetec via Cardholder credentials
On site sirens audible alert individuals in the case of intrusion system activation. Both interior and exterior sirens should be considered.
Individual Genetec alarms are created for each point or similar group of points as authorized by DoIT
System allows 60 seconds to exist prior to arming and 45 seconds to disarm post entry
All detection devices, including motion detectors, glass break sensors, and door and window contacts trigger and immediate alarm, except if those sensors are triggered by the entry of a person disarming the system.
Panel password and configuration is made available to the CoD
All points are tested and confirmed to operate as expected prior to commissioning of the system.
All exposed intrusion system cabling shall be routed withing conduit to provide against physical damage
Communication and equipment room cabling shall be routed within conduit, slotted cable duct, or coverable cable raceways.
Structured Cabling and Security System Standards 23
SYSTEM TESTING
NETWORK TESTING REQUIRMENTS
All copper drops must be certified utilizing a device designed to certify according to TIA/ISO standards. Some examples include Fluke Networks DSX, AEM TestPro CV100, and VIAVI Solutions Certifier. The certification report shall be provided to the COD in electronic format.
Fiber optic cable shall be tested with a calibrated OLTS or OTDR appropriate for the fiber type and wavelength under test
Report of test results shall be provided to DoIT at the end of project
Structured Cabling and Security System Standards 24
CLOSEOUT AND DOCUMENTATION
DOCUMENTATION REQUIREMNTES
As-builts provided at end of project shall include:
Hardware cut sheets and user manuals
Warranty information
Hardware inventory report in CoD Format
Drawings showing cable pathways, device locations
System test reports
COD HARDWARE INVENTORY
The following vendor supplied information shall be included on the hardware inventory report
Device type (camera, door, intrusion, server, other)
Device makes
Device model
Device location
Device name
MAC Address (if applicable)
Temporary device credentials
Structured Cabling and Security System Standards 25
PERMITS AND CODE INSPECTION
COMPLIANCE WITH BUILDING CODES
All projects must adhere to local, state, and federal building codes.
Prior to commencement of work, the appropriate low voltage and electrical permits must be obtained by the city of Detroit BSEED
Inspections must be scheduled with the CoD BSEED and passed prior to completion
Structured Cabling and Security System Standards 26
EXCEPTIONS
All exceptions under this standard must be submitted in writing and approved by the City of Detroit Department of Innovation and Technology
Structured Cabling and Security System Standards 27
DEFINITIONS
• BSEEED = CoD Buildings, Safety, Engineering, and Environmental Department
• CAT6 = Category 6 standard for twisted pair cable
• CoD = City of Detroit
• DoIT = Cod Department of Innovation and Technology
• DoIT PS = Public Safety
• DROP = a run of communication cable from the network switch to the connection point where a device is connected to the network
• MGN = Main Grounding Neutral
• OLTS = Optical loss test set
• PDU = Power distribution unit
• REX = Request to Exit Sensor
• UFER = Concrete encased electrical ground
• UTP = unshielded twisted pair
• VMS = Video Management System
Structured Cabling and Security System Standards 28
REFERENCE STANDARDS
• BICSI N1 - Installation Practices for Telecommunications and ICT Cabling and Related Cabling Infrastructure, 1st Edition; 2019.
• EIA/ECA-310 - Cabinets, Racks, Panels, and Associated Equipment; Revision E, 2005.
• NFPA 70 - National Electrical Code; Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.
• TIA-568 (SET) - Commercial Building Telecommunications Cabling Standard Set; 2019.
• TIA-568.2 - Balanced Twisted-Pair Telecommunications Cabling and Components Standards. 2009c, with Addendum (2016).
• TIA-569 - Telecommunications Pathways and Spaces; 2019e.
• TIA-606 - Administration Standard for Telecommunications Infrastructure; 2017c.
• TIA-607 - Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises; 2019d.
• UL 444 - Communications Cables; Current Edition, Including All Revisions.
• UL 514C - Nonmetallic Outlet Boxes, Flush-Device Boxes, and Covers; Current Edition, Including All Revisions.
• UL 1863 - Communications-Circuit Accessories; Current Edition, Including All Revisions.