39422 BURRELL LOCK REHAB BID dwngs 2024-02-19.pdf
PDF 22 MB Posted
- Attached to
- Burrell Lock Rehabilitation
- Solicitation number
- ITB-08249
- Issued by
- Lake County, Florida
About this file
This document is related to a state and local government contract opportunity for the Burrell Lock Rehabilitation project located in Lake County, Florida. The objective of this project is to repair the concrete surfaces, reline the lock inflow and outflow pipes, repair and paint the lock mitre gates, provide new mitre gate hydraulic operators, replace the upstream and downstream slide gates and provide new hydraulic operators, replace controls in the control building, and install manatee protection screens. Other miscellaneous work includes replacement of wood fenders, navigation lights, fire extinguisher cabinets, floatation rings, staff gages, signs, lock access gate and ladder, and removal and reinstallation of manatee detection system. The estimated budget for this project is $2.5M and a bid bond/guaranty is required. A non-mandatory pre-bid conference will be held on March 26, 2024 at 10:00 AM at the Burrell Lock & Dam. The Burrell Lock is located on Haines Creek connecting Lake Griffin and Lake Eustis in Lake County, Florida.
The contract opportunity indicates that the Florida State government is the primary jurisdiction, with Brevard County as the local jurisdiction. No information is provided regarding pricing terms, set asides, incumbents, funding requirements and sources, or any other salient financial details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BURRELL LOCK REHAB COST SCHEDULE 2024-02-21.xlsx | XLSX spreadsheet | |
| IFB 39422_Addendum 2 .pdf | ||
| IFB 39422_Addendum 1.pdf | ||
| COST SCHEDULE revised Addendum 2 - Copy.xlsx | XLSX spreadsheet | |
| IFB 39422Final Clean.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT
LOCATION
DRAWING FILENAME:
SHEET:
DATE:
P.E. NUMBER:
CERTIFICATION:
U :\P ro je ct s\
C
AD
D \U
O R
B\
BU
R R
EL
L
LO
C
K R
EH
AB
IL
IT
AT
IO
N \0
Pr od uc tio n
D ra w in gs \C
IV
IL
\C O
VE
R
S H
EE
T.
dw g
VICINITY MAP
ST. JOHNS RIVER WATER MANAGEMENT DISTRICT
UPPER OCKLAWAHA RIVER BASIN
BURRELL LOCK REHABILITATION
LAKE COUNTY, FLORIDA
WILLIAM R. COTE
53746
FEBRUARY 19, 2024 C1
COVER SHEET.dwg
A
F
CI
X
O
EM
ULF
O
G
POLK
OKEECHOBEE
INDIAN RIVER
OSCEOLA
BR
EV
AR
D
O
SC
EO
LA
VOLUSIA
SEMINOLE
ORANGE
LAKE N
BAKER
FL
AG
LE
RALACHUA
PUTNAM
MARION
O
T
CI
E C
CLAY
BRADFORD
DUVAL
ST
. J
O H
N
S LT
A A
N
NASSAU
PROJECT
LOCATION
NGVD 1929
ALL ELEVATIONS DEPICTED HEREIN
REFERENCE NGVD 1929 UNLESS
OTHERWISE NOTED. THE CONVERSION
FACTOR TO NAVD 1988 IS -1.05'.
NO. REVISION BY APPROVEDDATE DATE
ENGINEER'S NOTES:
1. These drawings are prepared for the sole and exclusive use of the St. Johns River Water Management District and shall not be relied upon by any other entity or individual.
2. Reproductions of these drawings are "NOT VALID WITHOUT THE
SIGNATURE AND THE ORIGINAL SEAL OF A FLORIDA LICENSED
ENGINEER."
NOT TO SCALE
LOCATION MAP
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
INDEX OF PLANS
SHEET NO. SHEET TITLE
SJRWMD PLANS
C1 COVER SHEET
C2 KEY MAP WITH AERIAL
C3 EROSION AND SEDIMENT CONTROL
S1 NOTE SPECIFICATIONS
S2 LOCK PLAN AND SECTION
S3 EXISTING LOCK INLET SECTIONS
S4 EXISTING LOCK CHAMBER AND OUTLET SECTIONS
S5 MISCELLANEOUS DETAILS
S6 LOCK GATES AND NOTES
S7 LOCK GATE DETAILS
S8 LOCK GATE OPERATORS
S9 EXISTING SLIDE GATE ELEVATIONS AND SECTIONS
S10 MANATEE SCREENS
S11 STEEL BULKHEAD INSTALLATION PLAN
S12 EXISTING STEEL BULKHEADS
S13 BULKHEAD SECTIONS AND DETAILS
S14 SIGN LOCATION PLAN AND SCHEDULE
BLACK & VEATCH PLANS
E-001 ELECTRICAL LEGEND
E-002 ELECTRICAL ABBREVIATION AND NOTES
E-101 OVERALL SITE PLAN
E-601 ONE-LINE DIAGRAM DEMOLITION
E-602 ONE-LINE DIAGRAM NEW WORK
1 ISSUED FOR BID N.J.G. W.R.C.02/19/24 02/19/24
CONCRETE GENERATOR PAD
LOCK CONTROL BLDG.
MAINTENANCE
SHED
ENTRANCE GATE
ELECTRICAL BLDG.
STORAGE SHED
PROPERTY BOUNDARY
TURBIDITY BARRIERS
BU
RR
EL
L
DA
M
BU
TL
ER
C
IR
C
LE
HAYNES CREEK
BURRELL LOCK
HAYNES CREEK
HAYNES CREEK
HAYNES CREEK BOAT CHANNEL
LO
CK R
OAD
CYPRESS ROAD
SHANNON AVENUE
KIM
BERLY DRIVE
E
E
ELECTRICAL MANHOLE
ELECTRICAL MANHOLE
GRAPHIC SCALE
SCALE: 1" = 40'
40 80
U :\P ro je ct s\
C
AD
D \U
O R
B\
BU
R R
EL
L
LO
C
K R
EH
AB
IL
IT
AT
IO
N \0
Pr od uc tio n
D ra w in gs \C
IV
IL
\K
EY
M
AP
W
IT
H A
ER
IA
L.
dw g
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:
P.O. BOX 1429 PALATKA, FLORIDA
REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
KEY MAP WITH AERIAL.dwgUPPER OCKLAWAHA RIVER BASIN
BURRELL LOCK REHABILITATION
LAKE COUNTY, FLORIDA N.J.G. FEBRUARY 19, 2024 W.R.C.
1" = 40' W.R.C. W.R.C.
KEY MAP WITH AERIAL
WILLIAM R. COTE
53746
FEBRUARY 19, 2024 C2
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
NOTE SPECIFICATIONS:
SUMMARY OF WORK / CONSTRUCTION SEQUENCE:
1. MOBILIZE LABOR AND EQUIPMENT TO THE SITE. ESTABLISH ON-SITE OFFICE AND STORAGE SPACES.
2. INSTALL ALL EROSION AND SEDIMENT CONTROL MEASURES.
3. INSTALL DEWATERING BULKHEADS AND SUPPORT FRAMING AT THE UPSTREAM AND DOWNSTREAM ENDS OF
THE LOCK STRUCTURE.
4. PUMP WATER FROM THE WORK AREA AND PROVIDE CONTINUOUS PUMPING TO KEEP THE WORK AREA DEWATERED. PUMPING SHALL BE IN A MANNER THAT WILL MINIMIZE SILTATION INTO THE WATERWAYS.
5. REMOVE MANATEE SONAR DETECTION SYSTEM. CAREFULLY STORE UNDER CLIMATE CONTROL FOR LATER
REINSTALLATION.
6. REMOVE SEDIMENT AND DEBRIS FROM THE STRUCTURE WORK AREA AND DISPOSE AT AN APPROVED
OFFSITE LOCATION.
7. PRESSURE WASH ALL CONCRETE AND STEEL SURFACES. AFTER WASHING THE DISTRICT AND CONTRACTOR SHALL PERFORM A JOINT INSPECTION TO DETERMINE THE FULL EXTENT AND SCOPE OF THE REPAIR WORK.
8. DISCONNECT POWER. DEMO AND DISPOSE OF THE FOUR LOCK MITRE GATE OPERATORS AND CONTROLS.
REMOVE THE LOCK MITRE GATES.
9. DEMO AND DISPOSE FOUR SLIDE GATES AND OPERATORS. KEEP THE EXISTING CONCRETE ANCHORS FOR
ATTACHING THE NEW GATES.
10. DEMO AND DISPOSE FOUR ABANDONED ELECTRICAL BOXES AND CONDUITS.
11. DEMO UPSTREAM AND DOWNSTREAM FENDERS. REPLACE WITH 3.5X7 PT WOOD. PROVIDE NEW GALVANIZED BOLTS, NUTS, AND WASHERS SIZED ACCORDING TO THE EXISTING FASTENERS TO BOLT ON TIMBER PILES.
12. DEMO INTERNAL LOCK FENDERS. UPON COMPLETION OF CONCRETE REPAIR, REPLACE WITH 2X6 COMPOSITE LUMBER. ANCHOR TO CONCRETE WALLS WITH NEW STAINLESS STEEL DRILLED ANCHORS, NUTS, AND
WASHERS SIZED ACCORDING TO THE EXISTING FASTENERS.
13. DEMO REPLACE NAVIGATION LIGHTS ON TOP OF PILES, TWO AT UPSTREAM AND TWO AT DOWNSTREAM ENDS
OF THE LOCK APPROACHES. REPLACE WITH NEW SOLAR MARINE LIGHTS AS SPECIFIED.
14. DEMO AND REPLACE TWO DISTRICT STAFF GAGES AS SPECIFIED.
REMOVE AND DISPOSE TWO DISTRICT STAFF GAGES AND REPLACE AS SPECIFIED.
15. DEMO AND DISPOSE FOUR FIRE EXTINGUISHER CABINETS AFFIXED TO THE LOCK RAILING. REPLACE WITH
FOUR UNITS OF JONESCO MODEL JBXE83, OR EQUAL.
16. DEMO AND DISPOSE FOUR THROWABLE FLOATATION RINGS WITH CABINET AFFIXED TO THE LOCK RAILING.
REPLACE WITH FOUR UNITS OF JIM BUOY SAFETY STATION MODEL 5070A WITH CABINET, 30-INCH RING, AND
60-FT. HEAVY LINE, OR EQUAL.
17. REMOVE AND DISPOSE 26 SIGNS AND REPLACE 23 SIGNS AS SPECIFIED. REMOVE AND SALVAGE 7 SIGNS AND
REPLACE UPON COMPLETION OF LOCK REPAIRS.
18. LOCK MITRE GATE REHABILITATION:
REMOVE THE LOCK GATES, PERFORM JOINT INSPECTION, BLAST AND PAINT AS SPECIFIED. PREPARE SURFACES AND PAINT ALL MITRE GATE HANDRAILS. REPLACE GATE GREASE LINES, SEALS AND HARDWARE.
18.1 LOCK GATE STEEL REPAIRS (IF REQUIRED)
PATCH GATE STEEL AND HINGE SUPPORT BRACKETS AS NEEDED.
18.2 LOCK GATE HINGE PINS (IF REQUIRED)
INSPECT AND REPLACE THE HINGE PINS AS NEEDED.
18.3 LOCK GATE HINGE BEARINGS (IF REQUIRED)
INSPECT AND REPLACE THE HINGE BEARINGS AS NEEDED.
18.4 LOCK GATE LUMBER COMPONENTS (IF REQUIRED)
INSPECT AND REPLACE LUMBER COMPONENTS AS NEEDED.
19. CONCRETE HYDRODEMOLITION, IF NEEDED, SHALL BE AS SPECIFIED.
20. CONCRETE ISOLATED PATCHING, IF NEEDED, SHALL BE AS SPECIFIED.
21. CONCRETE REBAR REPAIR, IF NEEDED, SHALL BE AS SPECIFIED.
22. CONCRETE CRACK REPAIR, IF NEEDED, SHALL BE AS SPECIFIED.
23. CONCRETE SAWCUTTING, IF NEEDED, SHALL BE AS SPECIFIED.
24. CONCRETE ERODED SURFACE REPAIR, IF NEEDED, SHALL BE AS SPECIFIED.
25. CONCRETE TESTING SERVICES, IF NEEDED, SHALL BE AS SPECIFIED.
26. CONCRETE SURFACE SHALL BE AS SPECIFIED.
27. CONCRETE HYDRAULIC CYLINDER PITS SHALL BE AS SPECIFIED.
28. INSPECT, REPAIR LEAKS, AND PAINT THE 42-INCH DIAMETER LOCK FILL AND DISCHARGE PIPES AS SPECIFIED.
29. PAINT ALL EMBEDDED STEEL COMPONENTS WITH SHERWIN-WILLIAMS DURA-PLATE 235, 2 COATS 6 MILS DFT EACH COAT, OR EQUAL. SURFACE PREPARATION SHALL BE FOR IMMERSION SERVICE AND APPLICATION
SHALL BE IN ACCORDANCE WITH THE MANUFACTURER SPECIFICATIONS.
STAINLESS STEEL SHALL BE POWERWASHED ONLY.
GALVANIZED STEEL SHALL BE COATED WITH ZRC GALVANIZING COMPOUND, TWO COATS, 3 MILS DFT EACH COAT, OR EQUAL. SURFACE PREPARATION AND APPLICATION SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER SPECIFICATIONS.
30. FABRICATE AND INSTALL NEW HANDRAIL AT CYLINDER PITS, NEW LOCK ACCESS GATE AND REPLACE LADDER
LOCATED NEAR THE LOCK CONTROL BUILDING.
31. INSTALL A NEW ¾” DIAMETER STAINLESS STEEL WATER LINE AND WATER BIB IN THE NORTHEAST LOCK CORNER CONNECTED TO AND MIRRORING THE EXISTING WATER LINE AND BIB NEAR THE NORTHEAST LOCK CORNER. THE ANCHORED LINE SHALL EXTEND DOWN THE NORTHWEST WALL, ACROSS THE CONCRETE
FLOOR, AND UP THE NORTHEAST WALL.
32. UPON COMPLETION OF LOCK REPAIRS, INSTALL THE FOUR LOCK MITRE GATES AND THE FOUR NEW
HYDRAULIC OPERATORS.
33. INSTALL FOUR NEW SLIDE GATES AND FOUR NEW HYDRAULIC OPERATORS.
34. IN THE LOCK CONTROL BUILDING, INSTALL NEW CONTROL PANELS FOR THE MITRE GATE OPERATORS AND THE SLIDE GATE OPERATORS. INSTALL NEW CONDUITS AND WIRING TO CONNECT TO THE FOUR MITRE GATES AND THE FOUR SLIDE GATE OPERATORS. CONNECT POWER AND PERFORM DRY TEST OPERATION OF ALL GATES AND OPERATORS AND ADJUST AS NEEDED. AFTER LOCK IS FLOODED, TEST OPERATION OF ALL
GATES AND OPERATORS UNDER NORMAL OPERATING CONDITIONS AND ADJUST AS NEEDED.
35. INSTALL THE DISTRICT SUPPLIED NEW MANATEE PROTECTION SCREENS IN FRONT OF THE FOUR SLIDE GATES. ALSO INSTALL SCREENS AT THE TWO UPSTREAM PIPE INLETS AND AT THE TWO DOWNSTREAM PIPE
OUTLETS.
36. REINSTALL THE MANATEE SONAR DETECTION SYSTEM. RECALIBRATE THE SYSTEM WITH DIVERS AFTER THE
LOCK IS FLOODED.
37. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL SUBMIT ANNOTATED DRAWINGS AND SPECIFICATIONS DOCUMENTING ANY CHANGES TO REFLECT THE AS-BUILT CONDITIONS. CONTRACTOR SHALL ALSO SUBMIT AN AS-BUILT SITE SURVEY SIGNED AND SEALED BY A FLORIDA LICENSED PROFESSIONAL LAND SURVEYOR. ELECTRONIC FILES (DWG AND PDF) AND TWO HARD COPIES ARE
REQUIRED.
38. DEMOBILIZE INCLUDING SITE CLEAN UP, RESTORATION OF FINAL GRADE AND GRASSING TO ORIGINAL
CONDITION, AND REMOVAL OF ALL EROSION AND SEDIMENT CONTROLS.
02/19/24 02/19/241 ISSUED FOR BID N.J.G. W.R.C.
CURRENT
STREAM OR
TIDAL CREEK
ANCHOR
PILE LOCATIONS
TO CURRENT ACTION
MOORING BUOY W/ANCHOR
BARRIER MOVEMENT DUE
DREDGE OR FILL AREA
TYPE II TYPE I
FLOW FLOW
FLOW FLOW
STORMWATER RUNOFF
SILT
FLO
W
WATERCOURSE
NOT TO SCALE
STAKED TURBIDITY BARRIER
TURBIDITY BARRIER APPLICATIONS
NOT TO SCALE
NOT TO SCALE
TEMPORARY SILT FENCE DETAIL
LEGEND
NOT TO SCALE
FLOATING TURBIDITY BARRIERS
D1= 5' STD. (SINGLE PANEL FOR DEPTHS 5' OR LESS).
D2= 5' STD. (ADDITIONAL PANEL FOR DEPTHS > 5')
CURTAIN TO REACH BOTTOM UP TO DEPTHS OF 10 FEET TWO (2) PANELS TO BE
USED FOR DEPTHS GREATER THAN 10 FEET UNLESS SPECIAL DEPTH CURTAINS
SPECIFICALLY CALLED FOR IN THE PLANS OR AS DETERMINED BY THE ENGINEER.
NOTICE: COMPONENTS OF TYPE I AND II MAY BE SIMILAR OR IDENTICAL TO PROPRIETARY
DESIGN. ANY INFRINGEMENT ON THE PROPRIETARY RIGHTS OF THE DESIGNER SHALL BE
THE SOLE RESPONSIBILITY OF THE USER. SUBSTITUTIONS FOR TYPES I AND II SHALL BE
AS APPROVED BY THE ENGINEER.
GENERAL NOTES:
1. FLOATING TURBIDITY BARRIERS ARE TO BE PAID FOR UNDER
THE CONTRACT UNIT PRICE FOR FLOATING TURBIDITY
BARRIER, LF.
2. STAKED TURBIDITY BARRIERS ARE TO BE PAID FOR UNDER
THE CONTRACT UNIT PRICE FOR STAKED TURBIDITY
BARRIER, LF.
NOTES:
1. TURBIDITY BARRIERS ARE TO BE USED IN ALL PERMANENT BODIES OF WATER REGARDLESS
OF WATER DEPTH.
2. NUMBER AND SPACING OF ANCHORS DEPENDENT ON CURRENT VELOCITIES.
3. DEPLOYMENT OF BARRIER AROUND PILE LOCATIONS MAY VARY TO ACCOMMODATE
CONSTRUCTION OPERATIONS.
4. NAVIGATION MAY REQUIRE SEGMENTING BARRIER DURING CONSTRUCTION OPERATIONS.
5. TURBIDITY BARRIERS SHALL CONFORM TO SECTION 104 OF THE FDOT STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (LATEST EDITION).
NOTES:
TURBIDITY BARRIERS FOR FLOWING STREAMS AND TIDAL CREEKS MAY BE EITHER FLOATING, OR STAKED TYPES OR ANY COMBINATIONS OF TYPES THAT WILL SUIT SITE CONDITIONS AND MEET EROSION CONTROL AND WATER QUALITY REQUIREMENTS. THE BARRIER TYPE(S) WILL BE AT THE CONTRACTORS OPTIONS UNLESS OTHERWISE SPECIFIED IN THE PLANS, HOWEVER PAYMENT WILL BE UNDER THE PAY ITEM(S) ESTABLISHED IN THE PLANS FOR FLOATING TURBIDITY BARRIERS TO BE
INSTALLED IN VERTICAL POSITION UNLESS OTHERWISE DIRECTED BY THE DISTRICT.
1. EXCAVATE THE TRENCH.
4" DEEP BY THE BALE WIDTH.
2. PLACE AND STAKE BALES.
3. WEDGE LOOSE STRAW BETWEEN
THE BALES.
4. BACKFILL AND COMPACT THE
EXCAVATED SOIL.
NOTES:
1. INSPECTION SHALL BE FREQUENT AND REPAIR OR REPLACEMENT SHALL BE MADE
PROMPTLY AS NEEDED.
2. BALES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFULNESS SO AS NOT
TO BLOCK OR IMPEDE STORM FLOW OR DRAINAGE.
VE
R
TI
C
AL
ELEVATION SECTION
TYPE III SILT FENCE
SILT FENCE PROTECTION IN
DITCHES WITH INTERMITTENT FLOW
SILT FENCE PROTECTION
AROUND DITCH BOTTOM INLETS
SILT FENCE APPLICATIONS
NOTES FOR SILT FENCES
1. TYPE III SILT FENCE TO BE USED AT MOST LOCATIONS. WHERE USED IN DITCHES, THE SPACING FOR TYPE III SILT FENCE SHALL BE IN ACCORDANCE WITH SECTION V OF THE STATE OF FLORIDA EROSION AND SEDIMENT CONTROL
DESIGNER AND REVIEWER MANUAL (JULY 2013).
2. TYPE IV SILT FENCE TO BE USED WHERE LARGE SEDIMENT LOADS ARE ANTICIPATED. SUGGESTED USE IS WHERE FILL SLOPE IS 1:2 OR STEEPER AND LENGTH OF SLOPE EXCEEDS 25 FEET. AVOID USE WHERE THE DETAINED
WATER MAY BACK INTO TRAVEL LANES OR OFF THE RIGHT OF WAY.
3. DO NOT CONSTRUCT SILT FENCES ACROSS PERMANENT FLOWING WATERCOURSES. SILT FENCES ARE TO BE AT
UPLAND LOCATIONS AND TURBIDITY BARRIERS USED AT PERMANENT BODIES OF WATER.
4. WHERE USED AS SLOPE PROTECTION, SILT FENCE IS TO BE CONSTRUCTED ON 0% LONGITUDINAL GRADE TO
AVOID CHANNELIZING RUNOFF ALONG THE LENGTH OF THE FENCE.
5. SILT FENCE TO BE PAID FOR UNDER THE CONTRACT UNIT PRICE FOR STAKED SILT FENCE, (LF).
EROSION AND SEDIMENT CONTROL NOTES:
1. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING SILT FROM SITE IF NOT REUSABLE ON-SITE AND ASSURING
PLAN ALIGNMENT AND GRADE IN ALL WORK AT COMPLETION OF CONSTRUCTION.
2. ON-SITE PROTECTION IN ADDITION TO THE ABOVE MUST BE PROVIDED THAT WILL NOT PERMIT SILT TO LEAVE THE
PROJECT CONFINES DUE TO UNSEEN CONDITIONS OR ACCIDENTS.
3. THE FILTER BARRIER SHALL BE ENTRENCHED AND BACKFILLED. A TRENCH SHALL BE EXCAVATED TO A MINIMUM DEPTH OF 8 INCHES. THE EXCAVATED SOIL SHALL BE BACKFILLED AND COMPACTED AGAINST THE FILTER
BARRIER.
4. SILT FENCES AND FILTER BARRIERS SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST
DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY.
5. SHOULD THE FABRIC ON A SILT FENCE OR FILTER BARRIER DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL BE NECESSARY, THE FABRIC SHALL BE REPLACED
IMMEDIATELY.
6. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE OR FILTER BARRIER IS NO LONGER REQUIRED SHALL BE DRESSED TO CONFORM WITH THE EXISTING GRADE, PREPARED AND GRASSED.
7. THE CONTRACTOR IS RESPONSIBLE FOR FOLLOWING THE BEST EROSION AND SEDIMENT CONTROL PRACTICES AS OUTLINED IN THE PLANS, SPECIFICATIONS, PERMITS, AND ST. JOHNS RIVER WATER MANAGEMENT DISTRICT
CRITERIA.
8. FOR ADDITIONAL INFORMATION ON SEDIMENT AND EROSION CONTROL REFER TO STATE OF FLORIDA EROSION AND
SEDIMENT CONTROL DESIGNER AND REVIEWER MANUAL (LATEST EDITION).
9. ALL DISTURBED AREAS SHALL BE GRASSED, FERTILIZED, WATERED AND MAINTAINED UNTIL A PERMANENT VEGETATIVE COVER IS ESTABLISHED. GRASSING SHALL CONFORM TO THE REQUIREMENTS OF SECTIONS 570 AND 981 THRU 983 OF THE FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (LATEST EDITIONS). NOTE THAT OTHER GRASSING ALTERNATIVES MAY BE USED WITH PRIOR DISTRICT APPROVAL.
PERMIT CONDITIONS FOR MANATEE PROTECTION:
1. MANATEES ARE EXPECTED TO BE PRESENT AT THIS SITE DURING CONSTRUCTION. THE
CONTRACTOR SHALL COMPLY WITH ALL STANDARD MANATEE CONDITIONS IN THE PERMIT.
2. SILTATION OR TURBIDITY BARRIERS SHALL BE MADE OF MATERIAL IN WHICH MANATEES CANNOT
BECOME ENTANGLED, SHALL BE PROPERLY SECURED, AND SHALL BE REGULARLY MONITORED
TO AVOID MANATEE ENTANGLEMENT OR ENTRAPMENT. BARRIERS MUST NOT IMPEDE MANATEE
MOVEMENT.
3. CONTRACTOR SHALL PROVIDE MANATEE PROTECTION SCREENS WITH A MAXIMUM 8-INCH
OPENING FOR ANY AND ALL DEWATERING OUTLET PIPES.
STRAW BALE BARRIER
NOT TO SCALE
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
U :\P ro je ct s\
C
AD
D \U
O R
B\
BU
R R
EL
L
LO
C
K R
EH
AB
IL
IT
AT
IO
N \0
Pr od uc tio n
D ra w in gs \C
IV
IL
\E R
O
SI
O N
A N
D S
ED
IM
EN
T.
dw g
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
EROSION AND SEDIMENT.dwg
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
P.O. BOX 1429 PALATKA, FLORIDA
UPPER OCKLAWAHA RIVER BASIN
BURRELL LOCK REHABILITATION
LAKE COUNTY, FLORIDA N.J.G. FEBRUARY 19, 2024 W.R.C.
AS NOTED W.R.C. W.R.C.
EROSION AND SEDIMENT CONTROL
WILLIAM R. COTE
53746
FEBRUARY 19, 2024 C3
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
U :\P ro je ct s\
C
AD
D \U
O R
B\
BU
R R
EL
L
LO
C
K R
EH
AB
IL
IT
AT
IO
N \0
Pr od uc tio n
D ra w in gs \S
TR
U
C
TU
R
AL
\N O
TE
S
PE
C
S.
dw g
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
NOTE SPECS.dwg
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
P.O. BOX 1429 PALATKA, FLORIDA
UPPER OCKLAWAHA RIVER BASIN
BURRELL LOCK REHABILITATION
LAKE COUNTY, FLORIDA N.J.G. FEBRUARY 19, 2024 W.R.C.
NONE W.R.C. W.R.C.
NOTE SPECIFICATIONS
WILLIAM R. COTE
53746
FEBRUARY 19, 2024 S1
NOTE SPECIFICATIONS:
REFERENCE DOCUMENTS:
1. LOCK CONSTRUCTION DRAWINGS PREPARED BY GEE & JENSEN CONSULTING ENGINEERS, WEST
PALM BEACH, FLORIDA, DATED JANUARY 6, 1955.
GENERAL:
1. THE CONTRACTOR SHALL BE RESPONSIBLE TO FAMILIARIZE HIMSELF WITH THE NATURE AND
EXTENT OF THE CONTRACT DOCUMENTS, SCOPE OF WORK, LOCAL CONDITIONS, ALL FEDERAL,
STATE, AND LOCAL LAWS, RULES, AND REGULATIONS THAT MAY AFFECT THE WORK. THE
CONTRACTOR SHALL PROVIDE A GANTT CHART SCHEDULE FOR ALL THE PROPOSED WORK PRIOR
TO THE START OF CONSTRUCTION.
2. THE EXISTING CONDITIONS REPRESENTED IN THESE DRAWINGS ARE BELIEVED TO BE ACCURATE
ACCORDING TO THE INFORMATION AVAILABLE TO THE DISTRICT. HOWEVER, IT IS THE SOLE
RESPONSIBILITY OF THE BIDDER (CONTRACTOR) TO VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE DISTRICT PRIOR TO SUBMITTAL OF THE BID.
3. PERMITS:
THE CONTRACTOR SHALL COMPLY WITH THE CONDITIONS CONTAINED IN THE FOLLOWING PERMITS
WHICH HAVE BEEN OBTAINED BY THE DISTRICT:
· USACE NATIONWIDE PERMIT
· FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION, NOTICED GENERAL PERMIT.
THE CONTRACTOR SHALL OBTAIN ANY AND ALL REMAINING PERMITS AS REQUIRED FOR THE
CONSTRUCTION OF THE PROJECT.
4. THE CONTRACTOR SHALL CONDUCT ALL CONSTRUCTION OPERATIONS IN A MANNER WHICH DOES NOT CAUSE VIOLATIONS OF STATE WATER QUALITY STANDARDS. THE CONTRACTOR SHALL PROVIDE
ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES (SILT FENCE, HAY BALES,
TURBIDITY BARRIER, ETC.) AS REQUIRED FOR COMPLIANCE WITH FEDERAL, STATE, AND LOCAL
LAWS, RULES, AND REGULATIONS.
5. DURING CONSTRUCTION, ALL ERODIBLE GROUND AREAS AND SLOPES WHICH ARE DISTURBED
SHALL BE REVEGETATED WITH SOD, SEED, AND MULCH, OR OTHERWISE APPROPRIATELY
STABILIZED WITHIN 72 HOURS AFTER COMPLETION OF THE CONSTRUCTION ACTIVITY AND AT ANY
OTHER TIME AS NECESSARY TO PREVENT VIOLATIONS OF STATE WATER QUALITY STANDARDS.
UPON COMPLETION OF CONSTRUCTION, ALL DISTURBED AREAS SHALL BE SODDED IN ACCORDANCE
WITH FDOT SECTIONS 981, 982, AND 983. SOD SHALL BE BAHIA GRASS.
6. THE CONTRACTOR SHALL PROVIDE THE NECESSARY WATER CONTROL SUCH THAT ALL
CONSTRUCTION IS PERFORMED IN THE DRY. FOR THE PURPOSES OF THIS WORK, THE TERM “DRY” SHALL BE DEFINED AS SURFACES FREE OF MOISTURE, STANDING WATER, FLOWING WATER, RAIN, OR GROUNDWATER SEEPAGE EXCEPT AS OTHERWISE NOTED IN THE CONTRACT DOCUMENTS OR
AS OTHERWISE APPROVED BY THE DISTRICT. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS
NECESSARY TO CONTROL THE FLOW OF WATER.
7. THE CONTRACTOR SHALL PROTECT ALL UTILITIES AND OTHER SITE IMPROVEMENTS FROM DAMAGE
WHETHER OR NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL ASSUME ALL
RESPONSIBILITY FOR REPAIRS TO UTILITIES AND OTHER SITE IMPROVEMENTS DAMAGED DURING
CONSTRUCTION. ADDITIONALLY, THE WORK WILL BE CONSIDERED COMPLETE ONLY AFTER ALL
RUBBISH AND UNUSED MATERIAL DUE TO OR CONNECTED WITH THE WORK HAS BEEN REMOVED
AND THE PREMISES LEFT IN A CONDITION SATISFACTORY TO THE DISTRICT.
8. THE CONTRACTOR SHALL REPAIR ALL AREAS DISTURBED DURING CONSTRUCTION TO ITS ORIGINAL
OR BETTER CONDITION.
9. THE CONTRACTOR SHALL PROVIDE ALL SAFETY AND TRAFFIC CONTROL NECESSARY FOR ACCESS
TO THE SITE AND WORK WITHIN THE PROJECT LIMITS.
10. THE CONTRACTOR SHALL COORDINATE ACTIVITIES AND COOPERATE WITH OTHER CONTRACTORS
AND DISTRICT PERSONNEL PERFORMING WORK WITHIN THE PROJECT LIMITS.
11. CONSTRUCTION INSPECTION WILL BE PERFORMED BY THE DISTRICT. THE CONTRACTOR SHALL NOTIFY THE DISTRICT AT LEAST 48 HOURS PRIOR TO THE REQUIRED TIME OF INSPECTION FOR EACH
AND EVERY PHASE OF WORK.
12. HOURS OF CONSTRUCTION OPERATIONS SHALL BE LIMITED TO BETWEEN THE HOURS OF 7 AM TO 6
PM.
13. THE CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF CONTRACT DOCUMENTS INCLUDING
DRAWINGS AND SPECIFICATIONS AT THE JOB SITE CLEARLY MARKED TO REFLECT ALL AS-BUILT
CONDITIONS. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL SUBMIT THESE
ANNOTATED DRAWINGS AND SPECIFICATIONS TO THE DISTRICT. CONTRACTOR SHALL ALSO SUBMIT
AN AS-BUILT SITE SURVEY SIGNED AND SEALED BY A FLORIDA LICENSED LAND SURVEYOR.
CONCRETE REPAIR:
1. THE SCOPE AND EXTENT OF ALL CONCRETE REPAIR WORK SHALL BE FIELD DETERMINED DURING
THE JOINT INSPECTION BY THE DISTRICT AND THE CONTRACTOR. THE CONTRACTOR SHALL
ARRANGE FOR, AND PROVIDE, THE SERVICES OF THE PRODUCT MANUFACTURER'S TECHNICAL
REPRESENTATIVE FOR THIS MEETING TO REVIEW AND DISCUSS THE REPAIR SCOPE OF WORK,
TECHNIQUES, AND PROCEDURES. THE PRODUCT REPRESENTATIVE SHALL ALSO BE PRESENT FOR
AN INITIAL CONCRETE REPAIR OPERATION SITE VISIT FOR THE PURPOSE OF CONFIRMING THAT THE
CONTRACTOR'S PERSONNEL ARE PROPERLY APPLYING THE REPAIR MATERIAL AND TO WITNESS
THE FIRST APPLICATION OF EACH TYPE OF REPAIR MATERIAL INSTALLED.
2. THE CONTRACTOR SHALL INSPECT AND PROBE CONCRETE SURFACES TO IDENTIFY AND LOCATE ALL AREAS OF DETERIORATION. REPAIR AREAS SHALL INCLUDE CONCRETE FOUND TO BE CRACKED, SPALLED, OR OTHERWISE SHOWING EVIDENCE OF DISINTEGRATION OR STRUCTURAL FAILURE.
3. SURFACE PREPARATION: ALL ERODED, DAMAGED, DETERIORATED, LOOSENED, OR UNBONDED
PORTIONS OF EXISTING CONCRETE SHALL BE REMOVED BY HIGH PRESSURE HYDROBLASTING
(8000-12000 PSI) TO ACHIEVE A SOUND EXPOSED AGGREGATE SURFACE WITH A MINIMUM SURFACE
PROFILE EQUAL TO CSP 6 - 9 IN ACCORDANCE WITH ICRI GUIDELINE 310.2. THE PRODUCT
REPRESENTATIVE SHALL INSPECT AND APPROVE IN WRITING THAT THE SURFACE PREPARATION IS
ACCEPTABLE FOR THE APPLICATION OF THE REPAIR PRODUCTS. GENERALLY, THE CONCRETE
AREAS TO BE HYDROBLASTED WILL BE TO A DEPTH OF LESS THAN 1 INCH. THE FINAL EXTENT OF THE HYDRODEMOLITION AREA WILL BE DETERMINED DURING CONSTRUCTION AS DICTATED BY THE
EXISTING CONDITIONS ENCOUNTERED.
REMOVAL OF DETERIORATED CONCRETE BY MECHANICAL MEANS SUCH AS BUSH HAMMERING, JACK
HAMMERING, SCABBLER, OR OTHER APPROPRIATE MEANS MAY BE USED SUBJECT TO DISTRICT
APPROVAL. IF MECHANICAL METHODS ARE USED, THE SURFACES SHALL BE FINISHED BY
HYDROBLASTING, SHOTBLASTING, OR WET SANDBLASTING WITH NON-METALLIC ABRASIVES TO
REMOVE ANY MICROFRACTURED SURFACES RESULTING FROM THE INITIAL REMOVAL PROCESS.
THE BOUNDARIES BETWEEN THE ERODED AND SOUND CONCRETE SURFACES, IF ANY AS
DETERMINED BY INSPECTION, SHALL BE SAWCUT IN ORDER TO PROVIDE A SMOOTH TRANSITION
FOR THE MORTAR REPAIR AREAS.
ALL REPAIR SURFACES SHALL BE THOROUGHLY CLEANED WITH WATER UNDER PRESSURE. THE
SURFACE MUST BE CLEAN AND FREE OF LOOSE CONCRETE, LAITANCE, DIRT, GREASE, FORM OIL, EFFLORESCENCE, PAINT, AND ANY OTHER FOREIGN MATERIAL.
4. CONCRETE SURFACE REPAIRS MAY GENERALLY CONSIST OF EITHER HAND-APPLIED OR MACHINE
APPLIED METHODS.
5. ALL SURFACE PREPARATION AND APPLICATION SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER SPECIFICATIONS. CONTRACTOR SHALL CONSULT IN THE FIELD WITH
MANUFACTURER AND DISTRICT PRIOR TO SURFACE PREPARATION AND REPAIR. FOR SPECIFIC
SURFACE PREPARATION REQUIREMENTS, REFER TO INTERNATIONAL CONCRETE REPAIR INSTITUTE
(ICRI) GUIDELINE NO. 03732.
6. ALL LOOSE SCALE, RUST, CORROSION BY PRODUCTS, OR CONCRETE SHALL BE REMOVED FROM
EXPOSED REINFORCING STEEL (REBAR) BY MECHANICAL CLEANING METHODS. REBAR EXPOSED
FOR MORE THAN ONE-THIRD OF ITS CIRCUMFERENCE SHALL BE COMPLETELY EXPOSED TO
PROVIDE 1-INCH MINIMUM CLEARANCE BETWEEN THE REBAR AND THE CONCRETE. DAMAGED OR
DETERIORATED REBAR SHALL BE REMOVED AND REPLACED. REPLACEMENT REBAR SHALL BE
GRADE 60 DEFORMED BILLET STEEL BARS CONFORMING TO ASTM A-615. REINFORCEMENT SPLICES
SHALL BE AS FOLLOWS:
BAR SIZE SPLICE LENGTH (IN)
#3 12 #4 12 #5 15 #6 18 #7 24 #8 30
ALTERNATIVELY, MECHANICAL SPLICES MAY BE USED SUBJECT TO DISTRICT APPROVAL.
7. ALL EXPOSED AND REPLACEMENT REBAR SHALL BE COATED WITH DURALPREP AC AS
MANUFACTURED BY THE EUCLID CHEMICAL COMPANY, OR APPROVED EQUAL, PRIOR TO PATCHING
WITH THE REPAIR MORTAR.
8. ISOLATED SPALLS SHALL BE HAND PATCHED WITH TAMMS STRUCTURAL MORTAR AS
MANUFACTURED BY THE EUCLID CHEMICAL COMPANY, OR APPROVED EQUAL. EDGES OF SPALLS
SHALL BE SAWCUT DURING SURFACE PREPARATION TO A MINIMUM DEPTH OF 1/2 INCH. THE REPAIR AREA SHALL NOT BE LESS THAN 1/8” IN DEPTH. SUBSTRATE SHALL BE SATURATED SURFACE DRY
(SSD) WITH NO STANDING WATER DURING APPLICATION. THE PREPARED CONCRETE SUBSTRATE
SHALL BE PRIMED WITH A BRUSH OR SPRAY APPLIED COAT OF DURALPREP AC. THE PRIMER COAT OF DURALPREP AC MUST BE ALLOWED TO THOROUGHLY DRY BEFORE APPLICATION OF THE TAMMS
STRUCTURAL MORTAR. ALTERNATIVELY, AN SSD CONCRETE SURFACE CAN BE PRIMED WITH A
SCRUB COAT OF TAMMS STRUCTURAL MORTAR FOR HAND APPLICATIONS. THE REPAIR MUST BE
MADE BEFORE THE SCRUB COAT DRIES OUT.
9. OPEN CRACKS IN CONCRETE SHALL BE SAWCUT 1/4-INCH-WIDE X 1/4-INCH DEEP AND REPAIRED WITH TAMMS STRUCTURAL MORTAR. APPLY A PRIMER COAT OF DURALPREP AC OR A SCRUB COAT
OF TAMMS STRUCTURAL MORTAR TO THE CONCRETE SUBSTRATE PRIOR TO PATCHING.
10. CRACKS WITH FLOWING WATER SHALL BE REPAIRED WITH CHEMICAL GROUT AS DETAILED ON THE
DRAWINGS PRIOR TO CONCRETE SURFACE REPAIR. CUT AND REMOVE EXCESS CHEMICAL GROUT
PRIOR TO CONCRETE REPAIR. WHEN SEALING VERTICAL CRACKS, BEGIN AT THE BOTTOM AND
WORK UP. WHERE WATER FLOW IS PRESENT, BEGIN INJECTING CRACK AT THE POINT OF LEAST FLOW AND WORK TOWARDS AREA OF HEAVIEST FLOW. CHEMICAL GROUT SHALL BE HYDRO ACTIVE
FLEX AS MANUFACTURED BY DE NEEF CONSTRUCTION CHEMICALS, INC., OR APPROVED EQUAL.
11. ERODED CONCRETE SURFACES SHALL BE REPAIRED WITH TAMMS STRUCTURAL MORTAR.
APPLICATION MAY BE BY TROWEL OR LOW-PRESSURE WET SPRAY PROCESS. AN EVAPORATION
RETARDANT, SUCH AS EUCOBAR AS MANUFACTURED BY THE EUCLID CHEMICAL COMPANY, OR
APPROVED EQUAL, SHALL BE USED IF REQUIRED BY WEATHER CONDITIONS. SURFACE
PREPARATION, APPLICATION, AND CURING SHALL BE IN ACCORDANCE WITH THE MANUFACTURER SPECIFICATIONS. THE REPAIR AREA SHALL NOT BE LESS THAN 1/8” IN DEPTH. SUBSTRATE SHALL BE SSD WITH NO STANDING WATER DURING APPLICATION. FOR HAND APPLICATION, THE PREPARED CONCRETE SUBSTRATE SHALL BE PRIMED WITH A BRUSH OR SPRAY APPLIED COAT OF DURALPREP
AC. THE PRIMER COAT OF DURALPREP AC MUST BE ALLOWED TO THOROUGHLY DRY BEFORE
APPLICATION OF THE TAMMS STRUCTURAL MORTAR. ALTERNATIVELY, AN SSD CONCRETE SURFACE CAN BE PRIMED WITH A SCRUB COAT OF TAMMS STRUCTURAL MORTAR FOR HAND APPLICATIONS.
THE REPAIR MUST BE MADE BEFORE THE SCRUB COAT DRIES OUT. AT NO TIME SHALL THE REPAIR MORTAR MIX BE ALLOWED TO EXCEED 90 DEGREES FAHRENHEIT. COLD WATER SHALL BE USED IN
THE MIX AS REQUIRED TO MAINTAIN THE PROPER TEMPERATURE.
12. CURING: ALL MORTAR REPAIRS SHALL BE WATER CURED FOR 7 DAYS FOLLOWING APPLICATION.
MOIST CURE IMMEDIATELY AFTER FINISHING WITH WET BURLAP AND POLYETHYLENE OR A FINE MIST OF WATER. IF NECESSARY, PROTECT NEWLY APPLIED MATERIAL FROM DIRECT SUNLIGHT, WIND, RAIN, AND FROST. AT NO TIME DURING THIS INITIAL CURING PERIOD SHALL THE MORTAR BE
ALLOWED TO DRY. FOLLOWING THE 7-DAY CURING PERIOD AND WHILE THE REPAIR IS STILL
SATURATED, THE SURFACE OF THE REPAIR SHALL RECEIVE TWO COATS OF THE SPECIFIED
PROTECTIVE COATING.
13. FOLLOWING COMPLETION OF MORTAR REPAIRS, ALL CONCRETE SURFACES SHALL BE COATED WITH SIKATOP 144 (CEMENT-GRAY COLOR), AS MANUFACTURED BY SIKA CORPORATION, OR APPROVED EQUAL, TO PROVIDE A UNIFORM APPEARANCE. APPLICATION SHALL BE WITH BRUSHES, ROLLERS, OR HOPPER-TYPE SPRAY EQUIPMENT. SURFACE SHALL BE SSD BEFORE APPLICATION. APPLY A
MINIMUM OF TWO COATS, 8-16 MILS DFT PER COAT, SUCH THAT THE SURFACE HAS A UNIFORM
APPEARANCE AND ALL POCK MARKS ARE FILLED. MOIST CURE WITH WET BURLAP AND
POLYETHYLENE OR A FINE MIST OF WATER FOR A MINIMUM OF 3 DAYS IN AREAS THAT WILL BE
SUBJECT TO IMMERSION.
14. SUBMITTALS: BEFORE BEGINNING ANY REPAIR WORK, THE CONTRACTOR SHALL SUBMIT A DETAILED LIST OF THE EQUIPMENT, PROCEDURES, AND MATERIALS PROPOSED FOR USE IN CONCRETE REPAIR
TO THE DISTRICT FOR APPROVAL.
15. POTABLE WATER SHALL BE USED FOR THE FINAL CLEANING OF CONCRETE SURFACES, FOR MIXING
WITH REPAIR PRODUCTS, AND FOR CURING REPAIRED SURFACES. CONTRACTOR SHALL BE
RESPONSIBLE FOR PROCURING POTABLE WATER AS REQUIRED FOR COMPLETION OF THE PROJECT.
CONCRETE TESTING SERVICES:
1. TESTING LABORATORY: THE DISTRICT SHALL RETAIN AN INDEPENDENT TESTING LABORATORY FOR
THE SAMPLING AND TESTING OF THE REPAIR MORTAR AND CAST IN PLACE CONCRETE. THE
LABORATORY'S INSPECTORS SHALL HAVE FREE ACCESS TO ALL POINTS WHERE CONCRETE
MATERIALS ARE STORED, PROPORTIONED, MIXED AND PLACED.
2. TEST SCHEDULING: CONTRACTOR SHALL ADVISE THE LABORATORY WITH TWENTY-FOUR (24)
HOURS ADVANCE NOTICE OF THE TIME AND LOCATION OF ALL REPAIR MORTAR AND CONCRETE
PLACEMENT OR OTHERWISE MAKE ARRANGEMENTS WITH THE LABORATORY SO THAT SAMPLES
MAY BE OBTAINED.
3. REPAIR MORTAR CUBE TESTS: CUBE SAMPLES (2” MORTAR CUBES) SHALL BE TAKEN AND TESTED IN
ACCORDANCE WITH ASTM C109 “STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF
HYDRAULIC CEMENT MORTARS.” CUBE TESTING SHALL INCLUDE ONE (1) AT 7-DAYS AND THREE (3) AT 28-DAYS. TWO (2) ADDITIONAL SAMPLES SHALL BE TESTED AT 56 DAYS IF DEEMED NECESSARY.
SAMPLING FREQUENCY FOR CUBES SHALL BE ONE PER DAY OR A MINIMUM OF ONE PER WORK
AREA, WHICHEVER IS GREATER. THE WORK AREAS ARE DEFINED AS EACH SEPARATE WALL AND
FLOOR AREA.
4. REPAIR MORTAR COMPRESSIVE STRENGTH: THE REPAIR MATERIAL SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 7000 PSI. COMPRESSION STRENGTH OF A SAMPLE SHALL BE DETERMINED BY THE AVERAGE OF THE THREE (3) SAMPLES TESTED AT TWENTY-EIGHT (28) DAYS.
COMPLIANCE WITH THE STRENGTH REQUIREMENTS OF THESE SPECIFICATIONS SHALL BE VERIFIED
IF THE AVERAGE COMPRESSIVE STRENGTH OF THREE (3) CONSECUTIVE SAMPLES IS NOT LESS
THAN THE SPECIFIED STRENGTH FOR THE CLASS OF CONCRETE, PROVIDED NO INDIVIDUAL SAMPLE SHALL HAVE A STRENGTH TEST RESULT THAT FALLS BELOW THE SPECIFIED STRENGTH BY MORE
THAN SEVEN-HUNDRED (700) PSI. CONCRETE WHICH FAILS TO MEET STRENGTH REQUIREMENTS
SHALL BE FURTHER TESTED AS PROVIDED IN ACI 318 AT THE EXPENSE OF CONTRACTOR OR SHALL
BE REMOVED AS DETERMINED BY THE DISTRICT.
5. CONCRETE CYLINDER TESTS: CONCRETE CYLINDERS SHALL BE TAKEN AND TESTED IN
ACCORDANCE WITH ASTM C39 “STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF
CYLINDRICAL CONCRETE SPECIMENS.” SAMPLING FREQUENCY FOR CONCRETE SHALL BE FOR EACH
FIFTY (50) CUBIC YARDS OR PORTION THEREOF OF CONCRETE PLACED EACH DAY. THE
LABORATORY SHALL TAKE A SAMPLE FROM A BATCH OF ITS SELECTION AS THE CONCRETE IS BEING PLACED. NO WATER SHALL BE ADDED OR OTHER CHANGE MADE IN ANY BATCH AFTER IT HAS BEEN SAMPLED. IN ADDITION TO OTHER TESTS, THE LABORATORY WILL MAKE A SET OF FIVE (5) STANDARD COMPRESSION CYLINDERS FROM EACH SAMPLE, ONE (1) OF WHICH WILL BE TESTED AT SEVEN (7) DAYS AND THREE (3) TESTS AT TWENTY-EIGHT (28) DAYS AND AN ADDITIONAL SAMPLE SHALL BE
TESTED AT 56 DAYS IF DEEMED NECESSARY.
6. CONCRETE COMPRESSIVE STRENGTH: CAST-IN-PLACE CONCRETE SHALL ATTAIN A MINIMUM 28-DAY
COMPRESSIVE STRENGTH OF 5500 PSI. COMPRESSION STRENGTH OF A SAMPLE SHALL BE
DETERMINED BY THE AVERAGE OF THE THREE (3) CYLINDERS TESTED AT TWENTY-EIGHT (28) DAYS.
COMPLIANCE WITH THE STRENGTH REQUIREMENTS OF THESE SPECIFICATIONS SHALL BE VERIFIED
IF THE AVERAGE COMPRESSIVE STRENGTH OF THREE (3) CONSECUTIVE SAMPLES IS NOT LESS
THAN THE SPECIFIED STRENGTH FOR THE CLASS OF CONCRETE, PROVIDED NO INDIVIDUAL SAMPLE SHALL HAVE A STRENGTH TEST RESULT THAT FALLS BELOW THE SPECIFIED STRENGTH BY MORE THAN FIVE HUNDRED (500) PSI. CONCRETE WHICH FAILS TO MEET STRENGTH REQUIREMENTS MAY BE FURTHER TESTED AS PROVIDED IN ACI 318 AT THE EXPENSE OF CONTRACTOR OR SHALL BE
REMOVED AS DETERMINED BY DISTRICT'S PROJECT MANAGER.
7. REPORTS: THE TESTING LABORATORY SHALL SUBMIT A REPORT OF EACH TEST MADE, SIGNED AND SEALED BY A FLORIDA LICENSED PROFESSIONAL ENGINEER. INDIVIDUAL TEST REPORTS SHALL BE
SUBMITTED TO THE DISTRICT AS SOON AS THEY ARE AVAILABLE. A FINAL REPORT THAT
SUMMARIZES THE TESTING AND SAMPLING PROCEDURES AND COMPILES ALL THE INDIVIDUAL TESTS
SHALL ALSO BE SUBMITTED TO THE DISTRICT UPON CONCLUSION OF THE WORK.
STRUCTURAL STEEL:
1. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE IN ACCORDANCE WITH THE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) "SPECIFICATION FOR THE DESIGN,
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST EDITION.
2. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS) "STRUCTURAL
WELDING CODE" AWS D1.1.
3. ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE NEW AND CONFORM TO THE
REQUIREMENTS OF THE AMERICAN SOCIETY OF TESTING AND MATERIALS (ASTM) STANDARD A36
UNLESS NOTED OTHERWISE.
4. ALL BOLTS, NUTS AND WASHERS SHALL BE STAINLESS STEEL CONFORMING TO ASTM A276, TYPE 304, UNLESS NOTED OTHERWISE. THE SIZE AND LOCATION OF REPLACEMENT BOLTS SHALL MATCH
EXISTING.
5. ALL WELDING SHALL UTILIZE E70XX LOW-HYDROGEN ELECTRODES UNLESS NOTED OTHERWISE.
6. FIELD CORRECTING OF FABRICATED STEEL SHALL NOT BE PERMITTED ON MAJOR STRUCTURAL
MEMBERS WITHOUT PRIOR APPROVAL OF THE DISTRICT.
PAINTS AND PROTECTIVE COATINGS:
1. ALL STEEL SHALL BE PRIMED AND PAINTED IN ACCORDANCE WITH THE STEEL STRUCTURES
PAINTING COUNCIL (SSPC) "STEEL STRUCTURES PAINTING MANUAL".
2. PREPARE SURFACES AND PAINT ALL EXPOSED STEEL COMPONENTS. ITEMS TO BE PAINTED INCLUDE
STRUCTURAL STEEL, LOCK INLET AND OUTLET PIPES, AND ALL EMBEDDED STEEL (EXCLUDING
STAINLESS STEEL AND ALUMINUM ITEMS). ALL STAINLESS STEEL AND ALUMINUM ITEMS SHALL BE
THOROUGHLY CLEANED.
3. STEEL SURFACE PREPARATION SHALL BE AS FOLLOWS:
STRUCTURAL STEEL AND EMBEDDED STEEL: SSPC-10 NEAR WHITE BLAST CLEANING.
THE USE OF 100% SILICA BLAST MEDIA SHALL NOT BE ALLOWED ON THE CONSTRUCTION SITE.
BLAST MEDIA IF USED ON SITE WILL BE SUBJECT TO APPROVAL BY THE DISTRICT.
DURING SURFACE PREPARATION, CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO
CAPTURE PAINT PARTICLES AND BLAST MEDIA AND DISPOSE OFFSITE AT A MUNICIPAL OR
COMMERCIAL LANDFILL.
4. PROTECTIVE COATING FOR STRUCTURAL STEEL SHALL BE AS MANUFACTURED BY
SHERWIN-WILLIAMS (S-W), OR EQUAL, AS FOLLOWS:
FIRST COAT (PRIMER): S-W DURA-PLATE 235 4-8 MILS DFT
SECOND COAT: S-W DURA-PLATE 235 4-8 MILS DFT
THIRD (FINAL) COAT: S-W DURA-PLATE 235 4-8 MILS DFT
COLOR SHALL BE LIGHT GRAY. SURFACE PREPARATION AND APPLICATION SHALL BE IN
ACCORDANCE WITH THE PAINT MANUFACTURER SPECIFICATIONS.
5. PROTECTIVE COATING FOR ALL EMBEDDED GALVANIZED ITEMS SHALL BE AS FOLLOWS:
FIRST COAT (PRIMER): WASSER MC-ZINC 3-5 MILS DFT
SECOND COAT: S-W DURA-PLATE 235 4-8 MILS DFT
THIRD COAT: S-W DURA-PLATE 235 4-8 MILS DFT
COLOR SHALL BE LIGHT GRAY. SURFACE PREPARATION AND APPLICATION SHALL BE IN
ACCORDANCE WITH THE PAINT MANUFACTURER SPECIFICATIONS.
6. PROTECTIVE COATING FOR THE INLET AND OUTLET PIPES SHALL BE AS MANUFACTURED BY
SHERWIN-WILLIAMS, OR EQUAL, AS FOLLOWS:
FIRST COAT: TARGUARD LOW VOC COAL TAR EPOXY 8-16 MILS DFT
SECOND COAT: TARGUARD LOW VOC COAL TAR EPOXY 8-16 MILS DFT
COLOR SHALL BE BLACK. SURFACE PREPARATION AND APPLICATION SHALL BE IN ACCORDANCE
WITH THE PAINT MANUFACTURER SPECIFICATIONS.
7. WHERE SEEPAGE IS PRESENT AT THE INLET AND OUTLET PIPES, THE PROTECTIVE COATING SHALL
BE SOMAY HICOTE 151 AS MANUFACTURED BY SOMAY PRODUCTS, INC., OR EQUAL. SURFACE
PREPARATION AND APPLICATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER
SPECIFICATIONS. APPLY TWO COATS AT 10 MILS DFT.
8. PROTECTIVE COATINGS FOR WATER CONTROL GATES ARE SPECIFIED ON SHEET S6.
SUBMITTALS:
1. SAFETY PLAN FOR INFORMATION ONLY
2. CONSTRUCTION SCHEDULE
3. SILT FENCE AND TURBIDITY BARRIER DATA SHEETS
4. CONCRETE MORTAR REPAIR DATA SHEETS
5. CONCRETE MORTAR EVAPORATION RETARDANT DATA SHEETS
6. CONCRETE TOPCOAT DATA SHEETS
7. CONCRETE AND REBAR BONDING AGENT DATA SHEETS
8. CONCRETE CRACK WITH FLOWING WATER REPAIR PRODUCT DATA SHEETS
9. CONCRETE MIX DESIGN
10. JOINT CAULK DATA SHEETS
11. PAINT AND PROTECTIVE COATINGS DATA SHEETS
12. SIGNS SHOP DRAWINGS
13. MARINE NAVIGATION LIGHT DATA SHEETS
14. STAFF GAGE AND WATER DEPTH GAGE DATA SHEETS
15. LOCK ACCESS GATE AND LADDER SHOP DRAWING
16. EPOXY ANCHOR DATA SHEETS
17. GATE ANODE DATA SHEETS
18. GATE SEAL DATA SHEETS
19. GATE STAINLESS STEEL BOLT DATA SHEETS
20. GATE BRONZE NUT DATA SHEETS
21. AS-BUILT DRAWINGS
22. MITRE GATE HYDRAULIC OPERATORS
23. SLIDE GATES AND HYDRAULIC OPERATORS
24. HYDRAULIC POWER UNITS
25. CONTROL SYSTEM TO OPERATE THE MITRE AND SLIDE GATES
AS-BUILT REQUIREMENTS:
1. PROVIDE THE SURVEYOR'S CERTIFICATION AND INDICATE SURVEYED DATUM AND STATE PLANE
COORDINATE SYSTEM ON THE COVER SHEET.
2. DO NOT REMOVE ANY ORIGINAL DESIGN INFORMATION FROM THE CAD FILE, ALTER THE LINE WEIGHTS OR COLORS, NOR CHANGE THE SCALE OF ANY PLAN, PROFILE, OR SECTIONS. LEAVE THE
ORIGINAL DESIGN ELEVATIONS VISIBLE.
3. ADD AS-BUILT ELEVATION DATA, AS NEEDED, TO THE PROFILES AND SECTIONS WITHIN THE CAD FILE THAT HAS BEEN PROVIDED IN THE ZIP FILE, TO SHOW THAT THE CONSTRUCTION WAS DONE PER PLAN, AND CLEARLY NOTATE ANY DEVIATIONS FROM THE ISSUED FOR CONSTRUCTION DRAWINGS.
· PROVIDE THE AS-BUILT ELEVATION WITH A CLOUD AROUND EACH POINT FOR ALL PROPOSED
CUT AND FILL GRADING ELEVATIONS, INCLUDING SPOT GRADES AT THE BEGINNING AND END OF
ALL CUT AND FILL GRADING AREAS.
· IF A SHEET DOES NOT HAVE ANY AS-BUILT INFORMATION ON IT AND IS REMOVED FROM THE
INDEX OF PLANS ON SHEET C1, THEN THE ABSENCE OF THAT SHEET SHOULD BE NOTED ON
SHEET C1 OF THE AS-BUILT DRAWINGS.
EL. 62'-6"
'-0
'-0
20'-0"
114'-6"
74'-6" LOCK CHAMBER 20'-0"
2' -0
T/ WALL
EL. 67.5'
INSTALL INLET
MANATEE SCREEN (TYP.)
(DISTRICT SUPPLY)
1'-0"
L 42" DIA. PIPE
EL. 58.4375'
C
'-0
SHEET PILING
T/ EL. 50.0'
B/ EL. 37.0'
EL. 63'-6"
'-0
" B
ET
W
EE
N F
EN
D
ER
S
B/ SHT. PILE
EL. 37.0'
2' -0
1'
-0
SHEET PILE
T/ EL. 53.0'
B/ EL. 37.0'
S13
S13
2'- 0"
L 42" DIA. PIPE
EL. 54.5375'
C
CONTINUOUS SHEET PILING TO EL. 37.0'
'-4
S2
S13
S13
S13
8" 8"
'-0
'-2
'-2
66'-0" 8'-6"
'-0
'-0
10'-3"±
8'-9"
13'-0"
10'-0"
4'-0"
LOCK INLET
EXIST. 11
2" DIA. TIE-BACKS @ 2'-8"± O.C.
9'-0"
10'-0"
LOCK OUTLET
'-0
'-0
10'-0"
12'-0"
7' -9
7'
-9
7' -3
7'
-3
8'-0"
10'-0" 2'-0"
12'-0"
8'-6"
11'-0" 8'-0"
9'-0" 6'-0"
5'-6" 5'-6"
3"
2'-0"
3"
2'-5"
7' -3
7'
-9
7' -9
7'
-3
16'-0"
CONC. APRON
15'-0"
3'-0"
9'-0"6'-0"
8"
8"
8"
4'-0"
4'- 0"
6' -4
6'
-4
27"
15"
2'-0"
1' -0
10'-0"
'-0
22'-0" 22'-0" 22'-0"
'-0
8'-0" 4'-0"
8'-6"15'-0"
22'-0" 22'-0" 22'-0" 8'-6"
1'-0"
EL.
56.0'
2'-0"
1'-0"
3'-0"
8"
8"
36"17'-0" (TYP.)36"
9' -0
(T
YP
14'-3"±
20'-0"
20'-0"
MAX. TAILWATER EL. 61.6'
NORMAL WATER EL. 59.3'
NAVIGATIONAL
LIGHT
HIGH WATER EL. 63.6'
NORMAL WATER EL. 63.3'
C PINTLE
C SLIDE
GATE C
C SLIDE
GATE D
C PINTLE
C P
IN
TL
E
L
L
C LOCK
L
L
L
C P
IN
TL
E L
C SLIDE
GATE B
L
C PINTLEL
C P
IN
TL
E L
C SLIDE
GATE A
L
C PINTLEL
C LOCK
C PINTLEL C PINTLEL
EXISTING
TIE-BACKS
LOCK TENDER
SIDE DAM SIDE
C O
R N
ER
O
F
SH
EE
T
PI
LE
T/ SHT. PILING
EL. 53'-0"
T/ SHT. PILING
EL. 50'-0"
EXISTING
TIE-BACK
8'-0" FROM
CORNER
OF SHEET
PILE
C .J
C .J
1' -6
1'
-6
1' -6
0' -8
3' -0
L
21'-0"
3'-0"
2' -0
FLOW FLOW
S2
LOCK PLAN
S2
LOCK SECTION
SCALE: 1/8" = 1'-0"
16'0' 4' 8'
SCALE: 1/8" = 1'-0"
16'0' 4' 8'
T/ WALL
EL. 67.5'
T/ WALL
EL. 62'-6"
SIDEWALK
18"x18" CONC. CAP
CONC. DEADMAN
(TYP. BOTH SIDES)
2" DIA. TIE-BACK
x 30'-0" (TYP.) SIDEWALKSIDEWALK
JOINT
T/ WALL
EL. 62'-6"
T/ WALL
EL. 67.5'
BEAM
POCKETS
16'-65 8"
CONCRETE APRON
EL. 52.0'
8" SLOT
SIDEWALK
T/ WALL
EL. 62'-6"
12"x12"
DOWNSTREAM
LOCK GATE
SUMP
EL. 52.33'
EL. 56.0'
EL. 52'-4"
EL. 56'-0"
UPSTREAM
LOCK GATE
SIDEWALK
FACE OF
MONOLITH
T/ WALL
EL. 62'-6"
T/ WALL
EL. 67.5'
8" SLOT
W12x65
W8x31
(TYP.)
BEAM
POCKETS EL. 55.0'
LL
CONTINUOUS SHT. PILING
ACROSS MITRE SILL
T/ WALL EL. 62'-6"
8" SLOT 18"x18"
CONC. CAP
T/ WALL
EL. 67.5'
MOTOR OPERATED
GATE LIFT
T/ WALL
EL. 67.5'
EL. 67.5' TOP OF 18"x18"
CONC. CAP EL. 67.5'
MOTOR OPERATED
GATE LIFT
T/ WALL
EL. 67.5'
8" SLOT 15" PILING 30'-0"
T/ FTG.
EL. 55.0'
C.J. C.J.
C.J.C.J.
EL. 63'-1 5/16"
FTG. EL. 52.33'
EL. 51.0'
BOTTOM EL. 49.0'
EL. 37.0'
2' -0
" EL. 52.0'
2'-8"
2'-5"
2'-0"
5' -0
21'-0"2'-0"
3'
'-4
S13
2' -0
FLOW
FLOW
4'- 0"
W12x30 W8x31
(TYP.)
W12x65
EL. 52.0'
B/ SHT. PILE
EL. 37.0'
2'-0"
W12x30
C P
IN
TL
E
15'-0"
STEEL DEWATERING
BULKHEADS
(DISTRICT SUPPLY)
WHILE FACING THE
STAFF GAGES, REPLACE
LEFT SIDE GAGE ONLY.
REPLACE NAVIGATION LIGHTS WITH SOLAR
MARINE BEACON LIGHT MODEL SNL-003
WHITE COLOR AS MANUFACTURED BY
BRITTA PRODUCTS INC., OR EQUAL. THIS
PRODUCT IS AVAILABLE AT PILOTLIGHTS.
NET. (TYP. 4 LOCATIONS)
REPLACE
NAVIGATION
LIGHT
REPLACE
NAVIGATION
LIGHT
REPLACE
NAVIGATION
LIGHT
STEEL DEWATERING
BULKHEADS
(DISTRICT SUPPLY)
WHILE FACING THE
STAFF GAGES, REPLACE
LEFT SIDE GAGE ONLY.
DEMO. 9"x9" ELECTRICAL BOX
CUT 4 - 58" DIA. BOLTS FLUSH
WITH CONCRETE
DEMO. 12"x12" ELECTRICAL BOX
CUT 4 - 58" DIA. BOLTS FLUSH
WITH CONCRETE
DEMO. 12"x12" ELECTRICAL BOX
CUT 4 - 58" DIA. BOLTS FLUSH
WITH CONCRETE
15'-0"
REPLACE WATER
DEPTH GAGE
EL. 51.0'EL. 51.0'
DEMO. 12"x12" ELECTRICAL BOX
CUT 4 - 58" DIA. BOLTS FLUSH
WITH CONCRETE
INSTALL NEW LADDER
CENTERED ON ACCESS
GATE
INSTALL NEW
ACCESS GATE
6'-10"2'-7"
CONC.
SHELF
CONC.
SHELF
EL. 66'-6"
INSTALL
UPSTREAM
BULKHEADS
(DISTRICT
SUPPLY)
INSTALL DOWNSTREAM
BULKHEADS
(DISTRICT SUPPLY)
NOTE:
THE STEEL DEWATERING BULKHEADS AND STRUCTURAL
STEEL SUPPORTS WILL BE SUPPLIED AND DELIVERED TO
THE SITE BY THE DISTRICT. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR UNLOADING AND INSTALLING THE
BULKHEADS AND SUPPORTS.
T/ FTG.
EL. 52.0'
FLOATING
TURBIDITY
BARRIER
FLOATING
TURBIDITY
BARRIER
DEMO AND REPLACE
EXTERIOR LOCK
FENDERS (TYP.)
DEMO AND REPLACE
EXTERIOR LOCK
FENDERS (TYP.)
EXISTING TELEMETRY
STATION
DEMO AND REPLACE INTERIOR
LOCK FENDERS (TYP.)
DEMO AND REPLACE EXTERIOR
LOCK FENDERS (TYP.)
DEMO AND REPLACE EXTERIOR
LOCK FENDERS (TYP.)
INSTALL OUTLET
MANATEE SCREEN (TYP.)
(DISTRICT SUPPLY)
S3
S3
S4
S4
S3
S3
S3
S3
S3
S3
S3
S4
S4
S4
S4
S4
S4
S9
S9
S9
S9
S3
S2
S13
S13
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
U :\P ro je ct s\
C
AD
D \U
O R
B\
BU
R R
EL
L
LO
C
K R
EH
AB
IL
IT
AT
IO
N \0
Pr od uc tio n
D ra w in gs \S
TR
U
C
TU
R
AL
\L O
C K
PL
AN
.d w g
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
LOCK PLAN.dwg
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
P.O. BOX 1429 PALATKA, FLORIDA
UPPER OCKLAWAHA RIVER BASIN
BURRELL LOCK REHABILITATION
LAKE COUNTY, FLORIDA N.J.G. FEBRUARY 19, 2024 W.R.C.
1/8" = 1'-0" W.R.C. W.R.C.
LOCK PLAN AND SECTION
WILLIAM R. COTE
53746
FEBRUARY 19, 2024 S2
30'-0"
8" 8"28'-8"
'-6
S3
LOCK INLET SECTION
SCALE: 1/4" = 1'-0"
0' 2' 4'
T/ WALL EL. 67'-6"
BOT. SHT. PILING
EL. 37'-0"
T/ FTG.
EL. 55'-0"
4" MIN.
VARIES
30'-0"
VARIES
SEE PLAN VARIES
'-6
6"
VA
R
IE
S
S3
LOCK INLET SECTION
SCALE: 1/4" = 1'-0"
0' 2' 4'
BOT. SHT. PILING
EL. 37'-0"
T/ WALL EL. 67'-6"
BULKHEAD SLOT
(TYP.)
T/ FTG.
EL. 55'-0"
24"
6'-0"
6"
#5 @ 12"
T. & B.
S3
LOCK INLET WINGWALL SECTION
VA
R
IE
S
#4 BAR
#7 L-BAR
6'-0" x 4'-9"
SCALE: 1/4" = 1'-0"
0' 2' 4'
T/ FTG. EL. 55'-0"
T/ WALL EL. VARIES
#5 @ 12"
SHEET PILING
'-6
8"
S3
LOCK INLET SECTION
SCALE: 1/4" = 1'-0"
0' 2' 4'
BOT. SHT. PILING
EL. 37'-0"
T/ WALL EL. 67'-6"
4" MIN.
VARIES
T/ SLAB
EL. 55'-0"
30'-0"
INSIDE FACE OF LOCK
T/ FTG.
EL. 52'-4"
EL. 51'-0" 16
S3
LOCK INLET SLAB SECTION
SCALE: 1/4" = 1'-0"
0' 2' 4'
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
U :\P ro je ct s\
C
AD
D \U
O R
B\
BU
R R
EL
L
LO
C
K R
EH
AB
IL
IT
AT
IO
N \0
Pr od uc tio n
D ra w in gs \S
TR
U
C
TU
R
AL
\L O
C K
IN
LE
T
SE
C
TI
O N
S.
dw g
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
LOCK INLET SECTIONS.dwg
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
P.O. BOX 1429 PALATKA, FLORIDA
UPPER OCKLAWAHA RIVER BASIN
BURRELL LOCK REHABILITATION
LAKE COUNTY, FLORIDA N.J.G. FEBRUARY 19, 2024 W.R.C.
1/4" = 1'-0" W.R.C. W.R.C.
EXISTING LOCK INLET SECTIONS
WILLIAM R. COTE
53746
FEBRUARY 19, 2024 S3
30'-0"
10" 28'-4"
5' -6
" 2' -6
'-2
#4 @ 12" TOP & BOT.
8'
-0
10"
C.J.
4" MIN.
VARIES
T/ FTG.
EL. 52'-4"
WEEP HOLES (TYP.)
#8 @ 12"
C.J.
#6 @ 12"
TIE-BACKS
@ 8'-0" O.C.
TIE-BACKS
@ 2'-8" O.C.
T/ WALL EL. 67'-6"
EXIST. CAP
#6 @ 12"
SHEET PILING
TIE-BACKS
@ 8'-0" O.C.
TIE-BACKS
@ 2'-8" O.C.
BOT. SHT. PILING
EL. 37'-0"S4
LOCK CHAMBER SECTION
SCALE: 1/4" = 1'-0"
0' 2' 4'
4" MIN.
VARIES
'-6
8"
8' -0
S4
LOCK CHAMBER SECTION
SCALE: 1/4" = 1'-0"
0' 2' 4'
BOT. SHT. PILING
EL. 37'-0"
T/ WALL EL. 67'-6"
C.J.
T/ SLAB
EL. 51'-0"
#4 @ 12" E.F., E.W.
TIE-BACKS
@ 8'-0" O.C.
TIE-BACKS
@ 2'-8" O.C.
27"
15" MIN.
VA
R
IE
S
6"
S4
LOCK OUTLET WINGWALL SECTION
SCALE: 1/4" = 1'-0"
0' 2' 4'
T/ WALL EL. VARIES
T/ SLAB
EL. 52'-0"
30'-0"VARIES
SEE PLAN
VARIES
'-6
6"
VA
R
IE
S
S4
LOCK OUTLET SECTION
SCALE: 1/4" = 1'-0"
0' 2' 4'
T/ WALL EL. 67'-6"
BOT. SHT. PILING
EL. 37'-0"
T/ FTG.
EL. 52'-0"
BULKHEAD SLOT
(TYP.)
SHEET PILING
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
U :\P ro je ct s\
C
AD
D \U
O R
B\
BU
R R
EL
L
LO
C
K R
EH
AB
IL
IT
AT
IO
N \0
Pr od uc tio n
D ra w in gs \S
TR
U
C
TU
R
AL
\L O
C K
C R
O
T
SE
C T.
dw g
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
LOCK CR & OT SECT.dwg
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
P.O. BOX 1429 PALATKA, FLORIDA
UPPER OCKLAWAHA RIVER BASIN
BURRELL LOCK REHABILITATION
LAKE COUNTY, FLORIDA N.J.G. FEBRUARY 19, 2024 W.R.C.
1/4" = 1'-0" W.R.C. W.R.C.
EXISTING LOCK CHAMBER AND OUTLET SECTIONS
WILLIAM R. COTE
53746
FEBRUARY 19, 2024 S4
S5
REPAIR FOR WALLS
S5
CONCRETE SURFACES S5
CONCRETE CRACKS WITH FLOWING WATER
S5
DEEP CONCRETE REPAIR FOR SLABS
SHALLOW MORTAR REPAIR
FOR WALL / SLAB CHEMICAL GROUTING DETAIL FOR
NOT TO SCALE
DEEP CONCRETE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
EXISTING
CONCRETE WALL
1/4" x 1" MIN. DEEP SAW CUT
ALL EDGES (SEE SHEET S1
CONCRETE REPAIR NOTES)
REPAIR MORTAR (SEE SHEET S1
CONCRETE REPAIR NOTES)
CLEAN SURFACE PRIOR TO PLACING
MORTAR (SEE SHEET S1 CONCRETE
REPAIR NOTES)
FOR SHALLOW REPAIRS GREATER THAN
1/2" DEEP APPLY REPAIR MORTAR IN LIFTS
IN ACCORDANCE WITH MANUFACTURERS
RECOMMENDATIONS, SCORE SURFACE
TO MAKE ROUGH, AND ALLOW TO SET
BEFORE APPLYING NEXT LIFT.
1/2" OR MORE
REMOVE ALL DETERIORATED
CONCRETE (1/4" MIN.)
CUT 1" MIN. OUTSIDE DETERIORATED
AREA (TYP.)
EXISTING
CONCRETE WALL
CONCRETE
REMOVAL LIMIT
EUCOCRETE
SUPREME
1" MIN.
3" MIN.
CLEAN EXPOSED REBARS AND COAT WITH
PROTECTIVE BONDING COMPOUND (SEE
SHEET S1 CONCRETE REPAIR NOTES)
PLACEMENT HOLE (AS REQUIRED)
REMOVE ALL DETERIORATED CONCRETE,
LEAVE SURFACE ROUGH - CLEAN SURFACE
PRIOR TO PLACING PLASTICIZED CONCRETE
3/4" MARINE GRADE PLYWOOD FORM
(TYP.) TEMPORARY FASTENERS USED TO
SUPPORT FORMWORK SHALL BE
REMOVED AND THE HOLES PATCHED
PRIOR TO SURFACE COATING.
1/4" x 1" MIN. SAW CUT ALL EDGES (SEE
SHEET S1 CONCRETE REPAIR NOTES)
EXISTING CRACK IN WALL OR SLAB
DRILL GROUT HOLES IN A STAGGERED
PATTERN ON EACH SIDE OF JOINT
MAXIMUM SPACING SHALL BE 3'-0" (6'-0"
O.C. ON EACH SIDE).
8"
CHEMICAL GROUT (SEE SHEET S1
CONCRETE REPAIR NOTES)
INJECTION PACKER
(REMOVE AFTER GROUTING)
45°
REMOVE ALL DETERIORATED CONCRETE,
LEAVE SURFACE ROUGH - CLEAN SURFACE
PRIOR TO PLACING PLASTICIZED CONCRETE
1" MIN.
1/4" x 1" MIN. DEEP SAW CUT ALL
SIDE (SEE SHEET S1 CONCRETE
REPAIR NOTES)
CONCRETE REMOVAL LIMITEUCOCRETE SUPREME
EXISTING CONCRETE
SLAB
3" MIN.
CLEAN EXPOSED REBARS AND COAT WITH
PROTECTIVE BONDING COMPOUND (SEE
SHEET S1 CONCRETE REPAIR NOTES)
A. QTY. 1
WALL MOUNT
WATER DEPTH GAUGE
12'-10"
2.5" TEXT
D
E
S5
WATER DEPTH GAGE (1 REQ'D)
0' 2'1'
SCALE: 3/4" = 1'-0"
4" WIDE
ALL HASH MARKS ARE
1.2" IN HEIGHT
3.25" WIDE
B
C
WATER
DEPTH
S5
BEACON LIGHT ATTACHMENT (4 REQ'D)
SCALE: 1" = 1'-0"
0' 1' 2'1/2'
ELEVATION
L PILEC
SECTION A-A
6" 3"
3"
4" DIA. x 6" COUNTERSUNK
LAG BOLTS
L PILEC
3"3"
A
2" x 12" x 12"
P.T. BASE
NEW MARINE
BEACON LIGHT
A
EXIST. TIMBER
PILE
S5
ACCESS GATE DETAIL
SCALE: 1 1/2" = 1'-0"
0 1'-0"6"3" 9"
LATCH
HINGE
ACCESS
GATE
2"
TOP OF
LOCK WALL
EXIST. RAILING
(TYP.)
EXIST. POST
(TYP.)
FOR BID PURPOSES ONLY
NOT FOR CONSTRUCTION
U :\P ro je ct s\
C
AD
D \U
O R
B\
BU
R R
EL
L
LO
C
K R
EH
AB
IL
IT
AT
IO
N \0
Pr od uc tio n
D ra w in gs \S
TR
U
C
TU
R
AL
\M
IS
C D
TL
S.
dw g
DRAWN:
SCALE:
DATE:
DESIGNER:
REVIEWER:
SECTION CHIEF:REVISIONNO. BY DATE APPROVED DATE DATE:
P.E. NUMBER:
CERTIFICATION: FILE NAME:
SHEET:
PROJECT NO.:
MISC DTLS.dwg
ST. JOHNS RIVER
WATER MANAGEMENT DISTRICT
P.O. BOX 1429 PALATKA, FLORIDA
UPPER OCKLAWAHA RIVER BASIN
BURRELL LOCK REHABILITATION
LAKE COUNTY, FLORIDA N.J.G. FEBRUARY 19, 2024 W.R.C.
AS NOTED W.R.C. W.R.C.
MISCELLANEOUS DETAILS
WILLIAM R. COTE
53746
FEBRUARY 19, 2024 S5
CONCRETE:
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF
TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION,
LATEST EDITION, SECTION 400 WITH SUPPLEMENTS AND ALL PERTINENT SPECIFICATIONS
CONTAINED THEREIN.
2. ALL CONCRETE SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 5,500 PSI.
PORTLAND CEMENT SHALL BE TYPE II IN ACCORDANCE WITH ASTM C-150. CONCRETE
SHALL BE AIR ENTRAINED WITH TOTAL AIR AS PERCENT BY VOLUME OF CONCRETE
EQUAL TO 4%. THE AIR ENTRAINING ADMIXTURE SHALL BE MICRO AIR, AS
MANUFACTURED BY MASTER BUILDERS, OR EQUAL, CONFORMING TO ASTM C-260. THE
AGGREGATES SHALL CONFORM TO ASTM C-33 AND SHALL HAVE A 3/4-INCH MAXIMUM
SIZE.
3. REINFORCING STEEL SHALL BE GRADE 60 DEFORMED BILLET STEEL BARS
CONFORMING TO ASTM A-615.
4. THE MINIMUM CLEAR CONCRETE COVER FOR REINFORCEMENT SHALL BE 3 INCHES FOR
FORMED SURFACES AND 4.5 INCHES FOR CONCRETE CAST AGAINST EARTH.
5. CRACKS WITH FLOWING WATER SHALL BE REPAIRED WITH CHEMICAL GROUT AS
DETAILED PRIOR TO CONCRETE SURFACE REPAIR. CUT AND REMOVE EXCESS CHEMICAL
GROUT PRIOR TO CONCRETE REPAIR. WHEN SEALING VERTICAL CRACKS, BEGIN AT THE
BOTTOM AND WORK UP. WHERE WATER FLOW IS PRESENT, BEGIN INJECTING CRACK AT
THE POINT OF LEAST FLOW AND WORK TOWARDS AREA OF HEAVIEST FLOW. CHEMICAL
GROUT SHALL BE HYDRO ACTIVE FLEX AS MANUFACTURED BY DENEEF CONSTRUCTION
CHEMICALS, INC., OR APPROVED EQUAL.
STAFF GAGE NOTES:
1. THERE ARE TWO STAFF GAGES AT BOTH THE UPSTREAM AND DOWNSTREAM LOCATIONS.
ONLY THE LEFT-HAND STAFF GAGES SHALL BE REPLACED. THE RIGHT-HAND STAFF
GAGES OWNED BY USGS SHALL REMAIN.
2. STAFF GAGES SHALL BE AS MANUFACTURED BY PERFORMANCE RESULTS PLUS INC. THE
WEB ADDRESS IS PRPH2O.COM.
3. THE LEFT-HAND UPSTREAM STAFF GAGE SHALL CONSIST OF ITEMS NOS. 801-017, 801-018, AND 801-019. THE VERTICAL DATUM SHALL BE SET TO NAVD88.
4. THE LEFT-HAND DOWNSTREAM STAFF GAGE SHALL CONSIST OF ITEMS NOS. 801-016,
801-017, AND 801-018. THE VERTICAL DATUM SHALL BE SET TO NAVD88.
5. THE MOUNTING BOARDS SHALL BE REPLACED WITH 1”X6” PRESSURE TREATED LUMBER.
THE GAGES SHALL BE ATTACHED TO THE MOUNTING BOARDS WITH STAINLESS STEEL
SCREWS AND RUBBER WASHERS. THE MOUNTING BOARDS SHALL BE ATTACHED TO THE
LOCK FENDERS WITH STAINLESS STEEL LAG BOLTS AND WASHERS.
WATER DEPTH GAGE NOTES:
MATERIALS KEY:
A. 2”X10” (1.5”X9.5”) MADE FROM TANGENT TECHNOLOGIES POLYFORCE RECYCLED PLASTIC
LUMBER, WHITE OVER BLACK, OR EQUAL.
B. TITLE PLAQUE INSERT:
WHITE WITH RED LETTERING AS FOLLOWS: “WATER DEPTH.”
C. GAGE SPLICE LINES (IF REQUIRED).
D. WALL MOUNTED GAGE:
ALL SLOTS ARE 0.6875”x7.3125”. THRU HOLES ARE 5/8” DIAMETER.
PROVIDE SS WASHERS ¼”X3”X4” AND SS CONCRETE ANCHORS.
E. 8” SS CLEAT MOUNTED WITH THREADED INSERTS.
HARDWARE:
ALL HARDWARE SHALL BE STAINLESS STEEL.
ASS-10 ALUM. ANODE
BOLTED TO U.S. FACE
(TYP.)
0' 1' 2'
SCALE: 1/2" = 1'-0"
S6
ELEVATION - DOWNSTREAM GATES (1 AS SHOWN, 1 OPP. HAND )
0' 1' 2'
SCALE: 1/2" = 1'-0"
S6
SECTION
7'-103 4" 7'-103
4"
17'-0"
LOCK FLOOR
EL. 51.0'
EL. 67.5'
3' -9
5'
-6
5' -6
1'
-9
8"
4" CLEAR
2' -0
2'
-0
2' -0
3'
-0
3' -8
1'
-1 1"
5' -1
13 8" 5'
-0
4' -1
1"
GALV. CLEVIS
4" GALV. L
6" x 3 8" x 1'-6" L
P P 12" I 35. #
HINGE
4" L (TYP.)P1
4" L (TYP.)
SEE DETAIL S6/5
SEE DETAIL S7/1
NEW 14" L (TYP.)P
8"" x 2'-0" CKD. LP
NEOPRENE SEAL
3" x 3" x 3 8" L
1 12" x 14" BENT LP
2" x 12" L CONT.P
4" DIA.
12" W @ 40#
6" I 17.35#
6" I 17.35#
6" I 17.35#
8" I…