36E77619R0073-0001003.pdf
PDF 6 MB Posted
- Solicitation number
- 36E77619R0073
About this file
36E77619R0073 0001 Attachment 3 - CD set_618-16-120 Upgrade Pharmacy 18_Part1.pdf
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
PROJECT NAME:
SITE ADDRESS:
VA PROJECT NUMBER:
OWNER AND CONSULTANTS:
VICINITY MAP:
AE PROJECT NUMBER: Dwg. of 781
CONSTRUCTION DOCUMENTS
C U s e rs \m p a rk e r\
D o c u m e n ts
\1
M in n e a p o lis
P h a rm a c y R e n o v a ti o n
R
C e n tr a l m o d e l_ m p a rk e rX U
R A
.r v t
/5
/2
:5
:5
A
M
1361-GI000
COVER SHEET UPGRADE PHARMACY 18
MINNEAPOLIS, MN
618-16-120
06/04/19 LA/BB CD
UPGRADE PHARMACY 18
1 Veterans Dr, Minneapolis, MN 55417
618-16-120
14849
VA COR:
CONTACT:
ADDRESS:
PHONE:
DANIEL FLECK
ONE VETERANS DRIVE
MINNEAPOLIS, MN 55417
612-467-4702
ARCHITECT:
NAME:
ADDRESS:
CONTACT:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
TOM OLESAK
PHONE: 763-412-4000 OR 763-412-4071
MEDICAL PLANNER:
NAME:
ADDRESS:
CONTACT:
LHB CORP
701 N WASHINGTON AVENUE
SUITE 200 MINNEAPOLIS, MN 55401
DANIEL MALDONADO
PHONE: 612-338-2029
MECH/PLUMB/FIRE ENGINEER:
NAME:
ADDRESS:
CONTACT:
DUNHAM ASSOCIATES INC.
50 SOUTH SIXTH STREET / SUITE 1100
MINNEAPOLIS, MN 55402-1540
JASON GOTTWALT
PHONE: 612-465-7273 FAX: 612-465-7073
FACILITIES ENGINEERING, PROJECTS SECTION
PROJECT MANAGER
ELECTRICAL ENGINEER:
NAME:
ADDRESS:
CONTACT:
DUNHAM ASSOCIATES INC.
50 SOUTH SIXTH STREET / SUITE 1100
MINNEAPOLIS, MN 55402-1540
CURT BARLAGE
PHONE: 612-465-7641 FAX: 612-465-7073
NORTHNORTH SITE LOCATION MAP:
Revisions: Date:
█ ISSUED
NOT ISSUED
ISSUED FOR REFERENCE ONLY
ISSUED AS NOTED
R
N
SHEET ABBREVIATION AND NUMBERING
AE 1 1 1 - 01
DI
SC
IP
LI
NE
D
ES
IG
NA
TO
R
SH
EE
T
TY
PE
D
ES
IG
NA
TO
R
FL
O
O R
LE
VE
L
SH
EE
T G
RO
UP
IN
G
ZO
NE
N
UM
BE
R
AE 111-01
ARCHITECTURAL ELEMENTS, PLAN, FIRST FLOOR, FLOOR PLAN, ZONE 1
QH 1 1 0 - 01
DI
SC
IP
LI
NE
D
ES
IG
NA
TO
R
SH
EE
T
TY
PE
D
ES
IG
NA
TO
R
FL
O
O R
LE
VE
L
SH
EE
T G
RO
UP
IN
G
ZO
NE
N
UM
BE
R
QH110-01
EQUIPMENT HOSPITAL, PLAN, FIRST FLOOR, FLOOR PLAN, ZONE 1
DISCIPLINE
DESIGNATOR
SHEET TYPE
DESIGNATOR
FLOOR
LEVEL
SHEET
GROUPING
GI - GENERAL INFORMATION
AD- ARCHITECTURAL DEMOLITION
AS-ARCHITECTURAL SITE
AE-ARCHITECTURAL ELEMENTS
AF-ARCHTECTURAL FINISHES
AC-REFLECTED CEILING PLANS
IF-INTERIOR FURNISHINGS
QC-EQUIPMETN LAUNDRY
QF-EQUIPMENT FOOD SERVICE
QH-EQUIPMENT HOSPITAL
QL-EQUIPMENT LABORATORY
0 - GENERAL
1 - PLANS
2 - ELEVATIONS
3 - SECTIONS
4 - LARGE SCALE VIEWS
5 - DETAILS
6 - SCHEDULES & DIAGRAMS
0 - LOWER LEVEL
1 - FIRST FLOOR
2 - SECOND FLOOR
3 - THIRD FLOOR
4 - FOURTH FLOOR
GENERAL:
00-10 - TITLE SHEET, NOTES,
ABBREVIATIONS, SYMBOLS,
SCHEDULES
PLANS:
1 - FLOOR PLAN
2 - DIMENSION PLAN
ELEVATIONS:
01-10 - EXTERIOR ELEVATIONS
11-19 - INTERIOR ELEVATION
SECTIONS:
01-10 - BUILDING SECTIONS
11-19 - WALL SECTIONS
20-29 - STAIR SECTIONS & PLANS
DETAILS:
01-19 - EXTERIOR PLAN DETAILS
20-29 - EXTERIOR SECTION DETAILS
30-39 - ROOF DETAILS
40-49 - INTERIOR PLAN DETAILS
50-59 - INTERIOR SECTION DETAILS
60-69 - CEILING DETAILS
PLANS ONLY
AE 5 1 2
DI
SC
IP
LI
NE
D
ES
IG
NA
TO
R
SH
EE
T
TY
PE
D
ES
IG
NA
TO
R
SH
EE
T G
RO
UP
IN
G
AE 501
ARCHITECTURAL ELEMENTS, EXTERIOR PLAN DETAILS
AF 6 7 0
DI
SC
IP
LI
NE
D
ES
IG
NA
TO
R
SH
EE
T
TY
PE
D
ES
IG
NA
TO
R
SH
EE
T G
RO
UP
IN
G
AF 670
ARCHITECTURAL FINISHES, FINISH SCHEDULE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSTRUCTION DOCUMENTS
AE PROJECT NUMBER: Dwg. of 78
C U s e rs \p c h o i\ D o c u m e n ts \1
M in n e a p o lis
P h a rm a c y R e n o v a ti o n
R
C e n tr a l m o d e l_ Y e u n y o u n g .r v t
/5
/2
:4
:1
P
M
1361-GI001
SHEET INDEX UPGRADE PHARMACY 18
MINNEAPOLIS, MN
618-16-120
06/04/19 LA/BB CD14849 2
SHEET INDEX - GENERAL, ARCHITECTURAL AND EQUIPMENT
PAGE
NO.
SHEET
NO. SHEET TITLE 6
5%
IS
SU
E
- 1 2/
/1
5%
IS
SU
E
- 0
3/
/1
IS
SU
E
- 0 4/
C O
NS
TR
UC
TI
O N
DO
CU
M
EN
TS
/0
4/
1 GI000 COVER SHEET █ █ █ █
2 GI001 SHEET INDEX █ █ █
3 GI002 ABBREVIATIONS █ █ █ █
4 GI003 GENERAL NOTES & SYMBOLS █ █ █ █
5 GI004 LOWER LEVEL LIFE SAFETY PLAN █ █ █ █
6 GI005 THIRD LEVEL LIFE SAFETY PLAN █ █
7 GI006 INFECTION CONTROL RISK ASSESSMENT PLAN █ █ █ █
8 GI007 CONSTRUCTION PHASING PLAN █ █ █ █
9 AD100 LOWER LEVEL DEMOLITION PLAN █ █ █ █
10 AD101 LOWER LEVEL INTERSTITIAL DEMOLITION PLAN █ █ █ █
11 AE100 LOWER LEVEL FLOOR PLAN █ █ █ █
12 AE101 LOWER LEVEL INTERSTITIAL PLAN █ █ █ █
13 AC100 LOWER LEVEL REFLECTED CEILING PLAN █ █ █ █
14 AE131 THIRD LEVEL PARTIAL PLANS █ █ █
15 AE132 THIRD LEVEL PARTIAL PLANS █ █
16 AE211 INTERIOR ELEVATIONS █ █ █ █
17 AE212 INTERIOR ELEVATIONS █ █ █
18 AE301 BUILDING SECTIONS █ █ █ █
19 AE411 ENLARGED PLANS & MOUNTING HEIGHTS █ █ █ █
20 AE540 INTERIOR DETAILS █ █ █ █
21 AE550 INTERIOR DETAILS █
22 AE551 INTERSTITIAL DETAILS █ █ █ █
23 AE601 PARTITION TYPES AND DETAILS █ █ █ █
24 AE602 DOOR & FRAME TYPES, SCHEDULE & DETAILS █ █ █ █
25 AW600 WAYFINDING PLANS & SCHEDULE █ █ █ █
26 AF101 LOWER LEVEL FINISH PLAN █ █ █ █
27 AF600 MATERIAL AND ROOM FINISH SCHEDULE █ █ █ █
28 QH100 LOWER LEVEL FURNITURE & EQUIPMENT PLANS █ █ █ █
29 QH401 ENLARGED FURNITURE & EQUIPMENT PLANS █ █ █
SHEET INDEX - PLUMBING, MECHANICAL AND ELETRICAL
PAGE
NO.
SHEET
NO. SHEET TITLE 6
5%
IS
SU
E
- 1 2/
/1
5%
IS
SU
E
- 0
3/
IS
SU
E
- 0 4/
NS
TR
UC
TI
O N
DO
CU
M
EN
TS
/0
4/
30 M000 MECHANICAL TITLE SHEET █ █ █ █
31 MD101 LOWER LEVEL HVAC DEMOLITION PLAN █ █ █ █
32 MD102 LOWER LEVEL INTERSTITIAL HVAC DEMOLITION PLAN █ █ █ █
33 MD103 LOWER LEVEL INTERSTITIAL HYDRONIC DEMOLITION PLAN █ █ █ █
34 MD131 THIRD LEVEL HVAC DEMOLITION PLANS █ █ █
35 MD151 PENTHOUSE HVAC DEMOLITION PLAN - SHAFT #2 █ █ █ █
36 M101 LOWER LEVEL HVAC PLAN █ █ █ █
37 M102 LOWER LEVEL INTERSTITIAL HVAC PLAN █ █ █ █
38 M103 LOWER LEVEL INTERSTITIAL HYDRONIC PLAN █ █ █ █
39 M131 THIRD LEVEL HVAC PLANS █ █ █
40 M151 PENTHOUSE PRE-CONSTRUCTION MECHANICAL PLAN - SHAFT #2 █ █ █ █
41 M152 PENTHOUSE MECHANICAL PLAN - SHAFT #2 █ █ █ █
42 M153 PENTHOUSE MECHANICAL PLAN - SHAFT #7 █ █ █ █
43 M501 MECHANICAL PLANS - SHAFT #7 █ █ █ █
44 M502 MECHANICAL DETAILS █ █ █ █
45 M601 MECHANICAL SCHEDULES AND OPERATION SEQUENCES █ █ █ █
46 M602 MECHANICAL ELELCTRICAL SCHEDULES █ █ █ █
47 M603 MECHANICAL ELELCTRICAL SCHEDULES █ █ █
48 PD101 UNDERFLOOR PLUMBING DEMOLITION PLAN █ █ █ █
49 PD102 LOWER LEVEL PLUMBING DEMOLITION PLAN █ █ █ █
50 PD103 LOWER LEVEL INTERSTITIAL PLUMBING DEMOLITION PLAN █ █ █ █
51 PD131 THIRD LEVEL PLUMBING DEMOLITION PLANS █ █ █
52 P101 UNDERFLOOR PLUMBING PLAN █ █ █ █
53 P102 LOWER LEVEL PLUMBING AND FIRE PROTECTION PLAN █ █ █ █
54 P103 LOWER LEVEL INTERSTITIAL PLUMBING PLAN █ █ █ █
55 P131 THIRD LEVEL PLUMBING PLANS █ █ █
56 P500 PLUMBING RISERS DIAGRAMS █ █ █ █
57 P501 PLUMBING RISERS DIAGRAMS █ █ █ █
58 P600 PLUMBING DETAILS AND SCHEDULES █ █ █ █
59 E000 ELECTRICAL TITLE SHEET █ █ █ █
60 E001 ELECTRICAL ZONING PLAN █ █ █ █
61 ED101 DEMOLITION LOWER LEVEL LIGHTING PLAN █ █ █ █
62 ED102 DEMOLITION LOWER LEVEL POWER PLAN █ █ █ █
63 ED103 DEMOLITION LOWER LEVEL SYSTEMS PLAN █ █ █ █
64 ED130 DEMOLITION THIRD LEVEL PLAN █ █ █ █
65 E101 LOWER LEVEL LIGHTING PLAN █ █ █ █
66 E102 LOWER LEVEL POWER PLAN █ █ █ █
67 E103 LOWER LEVEL SYSTEMS PLAN █ █ █ █
68 E104 LOWER LEVEL INTERSTITIAL PLAN █ █ █ █
69 E130 THIRD LEVEL PLAN █ █ █
70 E152 PENTHOUSE POWER PLAN █ █ █
71 E400 ENLARGED PLANS █ █ █
72 E500 ELECTRICAL DETAILS █ █ █
73 E501 ELECTRICAL DETAILS █ █
74 E600 ELECTRICAL EQUIPMENT PLAN AND SCHEDULES █ █ █
75 E601 ELECTRICAL SCHEDULES █ █ █
76 E602 ELECTRICAL SCHEDULES █ █ █
77 E603 SECURITY SURVEILLANCE PLAN AND SCHEDULE █ █
78 E604 ELECTRICAL RISER █ █ █ █
ARCHITECTURAL ABBREVIATIONS
A/C
A/C UNIT
A/E
AAMA
AAP
AB
ABC
ACI
ACS DR
ACS FLR
ACS PNL
ACST
ACT
AD
ADA
ADC
ADDL
ADDN
ADH
ADJ
ADMIN
AFF
AFG
AFS
AGC
AGGR
AHJ
AHR
AHU
AIA
AISC
ALT
ALT NO
ALUM
AMT
ANOD
ANSI
ANT
AP
APA
APC
APPD
APPROX
AR
ARCH
ASB
ASI
ASKLR
ASPH
ASSN
ASTM
ATCH
ATM
AUTO
AUX
AV
AVG
AW
AWI
AWPA
AWS
B PL
BAT
BD
BD FT
BEV
BHMA
BI FLD DR
BITUM
BKG
BLD
BLDG
BM
BOT
BRCG
BRDG
BRDG JST
BRG
BRG PL
BRKT
BRZ
BSMT
BTWN
BUR
C CONC
C TO C
CAB
CAC
CB
CBB
CCD
CCTV
CCW
CD
CEM
CEM PLAS
CER
CF
CF/CI
CF/OI
CFLG
CFMF
CG
CGSFU
CH
CHEM
CHFR
CHK
CI
CIP
CIR
CIRC
CJ
CL
CLDG
CLG
CLR
CM
CMU
AIR CONDITION
AIR CONDITIONING UNIT
ARCHITECT/ENGINEER
AMERICAN ARCHITECTURAL MANUFACTURERS ASSN
ALARM ANNUNCIATOR PANEL
ANCHOR BOLT
AGGREGATE BASE COURSE
AMERICAN CONCRETE INSTITUTE
ACCESS DOOR
ACCESS FLOOR
ACCESS PANEL
ACOUSTIC
ACOUSTICAL CEILING TILE
AREA DRAIN
AMERICANS WITH DISABILITIES ACT
AUTOMATIC DOOR CLOSER
ADDITIONAL
ADDITION
ADHESIVE
ADJACENT, ADJOINING, OR ADJUSTABLE
ADMINISTRATION
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ABOVE FINISHED SLAB
ASSOCIATED GENERAL CONTRACTORS
AGGREGATE
AUTHORITY HAVING JURISDICTION
ANCHOR
AIR HANDLING UNIT
AMERICAN INSTITUTE OF ARCHITECTS
AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALTERNATE
ALTERNATE NUMBER
ALUMINUM
AMOUNT
ANODIZE
AMERICAN NATIONAL STANDARDS INSTITUTE
ANTENNA
ACCESS PANEL
AMERICAN PLYWOOD ASSOCIATION
ARCHITECTURAL PRECAST CONCRETE
APPROVED
APPROXIMATE
AS REQUIRED
ARCHITECT
ASBESTOS
ARCHITECT'S SUPPLEMENTAL INSTRUCTION
AUTOMATIC SPRINKLER
ASPHALT
ASSOCIATION
AMERICAN SOCIETY FOR TESTING AND MATERIALS
ATTACHMENT
AUTOMATIC TELLER MACHINE
AUTOMATIC
AUXILIARY
AUDIO VISUAL
AVERAGE
ACID WASTE
ARCHITECTURAL WOODWORKING INSTITUTE
AMERICAN WOOD PRESERVERS' ASSOCIATION
AMERICAN WELDING SOCIETY
BASE PLATE
BATTEN
BOARD
BOARD FEET (FOOT)
BEVEL
BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION
BIFOLDING DOORS
BITUMINOUS
BACKING
BUILD
BUILDING
BEAM OR BENCHMARK
BOTTOM
BRACING
BRIDGING
BRIDGING JOIST
BEARING
BEARING PLATE
BRACKET
BRONZE
BASEMENT
BETWEEN
BUILT-UP ROOFING
CAST CONCRETE
CENTER TO CENTER
CABINET
CEILING ATTENUATION CLASS
CATCH BASIN OR CORNER BEAD
CEMENTITIOUS (BACKER) BOARD
CONSTRUCTION CHANGE DIRECTIVE
CLOSED CIRCUIT TELEVISION
COUNTERCLOCKWISE
CONSTRUCTION DOCUMENTS OR CONTRACT DOCUMENTS
CEMENT
CEMENT PLASTER
CERAMIC
CONTRACTOR FURNISHED
CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CONTRACTOR FURNISHED/OWNER INSTALLED
COUNTERFLASHING
COLD-FORMED METAL FRAMING
CORNER GUARD
CERAMIC GLAZED STRUCTURAL FACING UNITS
COAT HOOK
CHEMICAL
CHAMFER
CHECK
CAST IRON
CAST-IN-PLACE
CIRCLE
CIRCULAR
CONSTRUCTION JOINT OR CONTROL JOINT
CENTER LINE
CLADDING
CEILING
CLEAR
CONSTRUCTION MANAGEMENT
CONCRETE MASONRY UNIT
CNR
CNTR
CRTP
CO
CO2
COL
COM
COMB
COMM
COMP
CONC
CONC FLR
COND
CONF
CONN
CONSTR
CONT
CONTR
COORD
CORR
CPM
CPRS
CR
CRS
CRSI
CSB
CSG
CSI
CSK
CSMT
CSWK
CTG
CTR
CTRL
CTV
CU FT
CU IN
CU YD
CURT
CYL
CYL L
D
DAT
DBL
DBL GLZ
DCS
DP
DEG
DEL
DEMO
DEPT
DET
DF
DIA
DIAG
DIFF
DIM
DIR
DISP
DIST
DIV
DL
DOC
DR
DR CL
DR FR
DR OPNG
DS
DSGN
DW
DWG
E
EA
EFF
EFS
EIFS
EJ
EL
ELAST
ELEC
ELEC DR OP
ELEV
EMER
EMER SHR
ENCL
ENGR
ENVIR
EO
EPA
EPDM
EPO
EPS
EQ
EQL SP
EQUIP
EQUIV
ERD
ESC
ESMT
ESP
EST
ETC
EW
EWC
EWS
EXH
EXIST
EXP
EXP BT
EXST GR
EXT
EXT GR
CORNER
COUNTER
COUNTERTOP
CARBON MONOXIDE
CARBON DIOXIDE
COLUMN
COMMON
COMBINATION, COMBINED
COMMUNICATION
COMPONENT
CONCRETE
CONCRETE FLOOR
CONDENSER OR CONDITION
CONFERENCE
CONNECT
CONSTRUCTION
CONTINUE
CONTRACTOR
COORDINATE
CORRIDOR
CRITICAL PATH METHOD
COMPRESSIBLE
CRASH RAIL
COLD ROLLED STEEL
CONCRETE REINFORCING STEEL INSTITUTE
CONCRETE SPLASH BLOCK
CASING
CONSTRUCTION SPECIFICATIONS INSTITUTE
COUNTER SUNK
CASEMENT
CASEWORK
COATING
CENTER
CONTROL
CABLE TELEVISION
CUBIC FEET
CUBIC INCH
CUBIC YARD
CURTAIN
CYLINDER
CYLINDER LOCK
DEPTH OR PENNY (NAIL)
DATUM
DOUBLE
DOUBLE GLAZE
DIAPER CHANGING STATION
DECORATIVE PANEL
DEGREE
DELETE
DEMOLITION
DEPARTMENT
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIFFERENCE OR DIFFUSER
DIMENSION
DIRECTION
DISPENSER
DISTANCE
DIVIDE OR DIVISION
DEAD LOAD
DOCUMENT
DOOR, DRAIN, DRESSING ROOM, OR DRIVE
DOOR CLOSER
DOOR FRAME
DOOR OPENING
DOWNSPOUT
DESIGN
DISHWASHER
DRAWING
EAST
EACH
EFFICIENCY
EXTERIOR FINISH SYSTEM
EXTERIOR INSULATION AND FINISH SYSTEM
EXPANSION JOINT
ELEVATION
ELASTOMERIC
ELECTRIC
ELECTRIC DOOR OPENER
ELEVATOR
EMERGENCY
EMERGENCY SHOWER
ENCLOSURE
ENGINEER
ENVIRONMENT
ELECTRICAL OUTLET
ENVIRONMENTAL PROTECTION AGENCY
ETHYLENE PROPYLENE DIENE MONOMER
EMERGENCY POWER OFF
EXPANDED POLYSTYRENE BOARD (INSULATION)
EQUAL
EQUALLY SPACED
EQUIPMENT
EQUIVALENT
EXISTING ROOF DRAIN
ESCAPE OR ESCUTCHEON
EASEMENT
ESPECIALLY
ESTIMATE
AND SO FORTH OR ET CETERA
EACH WAY
ELECTRIC WATER COOLER
EYE WASH STATION
EXHAUST
EXISTING
EXPANSION OR EXPOSED
EXPANSION BOLT
EXISTING GRADE
EXTERIOR, EXTERNAL, OR EXTINGUISHER
EXTERIOR GRADE
F
FA
FAB
FAC
FACIL
FAS
FAS BD
FCU
FCO
FCTY
FD
FDC
FDV
FDTN
FE
FEC
FF
FF EL
FF&E
FHC
FHP
FIG
FIL
FIN
FIN FLR
FIN GR
FIN WD
FIXT
FL
FLASH
FLDG
FLEX
FLG
FLR
FLR FIN
FLR SK
FLUOR
FLUOR FIX
FM
FM-G
FO
FOC
FOF
FOM
FOS
FOUNT
FOW
FP
FR
FR SNK
FREQ
FRMG
FRP
FRZ
FS
FSB
FSTNR
FT
FTG
FURG
FURN
FUT
FVC
GA
GAL
GALV
GALV STL
GB
GC
GD
GDR
GEN
GFRC
GFRG
GFRP
GI
GL
GL BLK
GLU LAM
GP
GR FL
GRAN
GRTG
GSB
GSM
GSU
GT
GUAR
GUT
GYP
GYP BD
GYP PLAS
H
HAZ MAT
HB
HC
HCWD
HDBD
HDO
HDR
HDW
HDWD
HEPA
HEX
HGR
HM
HMD
HMDF
HMF
HNDRL
HO
HORIZ
HOSP
HP
HPD
HPDL
HQ
HS
HSE
HSKPG
FAHRENHEIT OR FEMALE
FIRE ALARM
FABRIC
FACTOR
FACILITY
FASCIA
FASCIA BOARD
FAN COIL UNIT
FLOOR CLEANOUT
FACTORY
FLOOR DRAIN
FIRE DEPARTMENT CONNECTION
FIRE DEPARTMENT VALVE
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FACE
FINISH FLOOR ELEVATION
FURNITURE, FIXTURE, AND EQUIPMENT
FIRE HOSE CABINET
FULL HEIGHT PARTITION
FIGURE
FILLET
FINISH
FINISH FLOOR
FINISH GRADE
FINISH WOOD
FIXTURE
FLOORLINE
FLASHING
FOLDING
FLEXIBLE
FLOORING
FLOOR
FLOOR FINISH
FLOOR SINK
FLUORESCENT
FLUORESCENT FIXTURE
FACTORY MUTUAL
FACTORY MUTUAL GLOBAL
FINISHED OPENING
FACE OF CONCRETE OR FACE OF CURB
FACE OF FINISH
FACE OF MASONRY
FACE OF SLAB OR FACE OF STUD
FOUNTAIN
FACE OF WALL
FIRE PROTECTION OR FIREPROOF
FIRE RATING, FIRE RESISTANT, OR FRAME
FLUSHING RIM SINK
FREQUENCY
FRAMING
FIBERGLASS REINFORCED PLASTIC
FREEZER
FEDERAL SPECIFICATION
FOLDING SHOWER BENCH
FASTENER
FEET OR FOOT
FOOTING
FURRING
FURNISH OR FURNITURE
FUTURE
FIRE VALVE CABINET
GAGE OR GYPSUM ASSOCIATION
GALLON
GALVANIC OR GALVANIZED
GALVANIZED STEEL
GRAB BAR
GENERAL CONTRACTOR
GUARD
GUARD RAIL
GENERAL OR GENERATOR
GLASS-FIBER-REINFORCED CONCRETE
GLASS-FIBER-REINFORCED GYPSUM
GLASS-FIBER-REINFORCED PLASTIC
GALVANIZED IRON
GLASS
GLASS BLOCK
GLUED LAMINATED WOOD
GRAB BAR
GROUND FLOOR
GRANITE
GRATING
GYPSUM SHEATHING BOARD
GALVANIZED SHEET METAL
GLAZED STRUCTURAL UNIT
GROUT
GUARANTEE
GUTTER
GYPSUM
GYPSUM BOARD
GYPSUM PLASTER
HIGH OR HUMIDISTAT
HAZARDOUS MATERIALS
HOSE BIBB
HOLLOW CORE
HOLLOW CORE WOOD DOOR
HARDBOARD
HIGH DENSITY OVERLAY
HEADER
HARDWARE
HARDWOOD
HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HEXAGON
HANGER
HOLLOW METAL
HOLLOW METAL DOOR
HOLLOW METAL DOOR AND FRAME
HOLLOW METAL FRAME
HANDRAIL
HOLD OPEN
HORIZONTAL
HOSPITAL
HIGH PRESSURE
HYGIENE PRODUCT DISPOSAL
HIGH PRESSURE DECORATIVE LAMINATE
HEADQUARTERS
HEAT-STRENGTHENED (GLASS) OR HIGH STRENGTH
HOUSE
HOUSEKEEPING
HST
HSS
HT
HVAC
HVY
HW
HYD
HYDR
IAQ
IBC
IC
ICW
ID
ID NO
ILLUM
INCL
IND
INFO
INSUL
INT
INTL
IWH
JAN
KD
KIT
KO
KPL
L
LAB
LAD
LAM
LAM GL
LAU
LAV
LBR
LBS
LCS
LD BRG
LDR
LED
LF
LIB
LIN
LIQ
LKR
LKR RM
LL
LMST
LRG
LRV
LT
LT GA
LT SW
LT WT
LTG
LTNG
LVD
LVR
LWC
LWIC
LYR
MACH
MACH RM
MAINT
MAN
MATL
MATV
MAX
MBD
MCB
MD
ME
MEAS
MECH
MECH RM
MED
MEK
MEMB
MEMO
MEZZ
MF
MFD
MFG
MFR
MFR REC
MGT
MIC
MID
MIL STD
MIN
MIR
MISC
MIT
MKR
ML
MLDG
MLWK
mm
MO
MOD
MOD BIT
MON
MOPR
MR
MS
MTD
MTG
MTL
MULL
MW
MWP
HOIST
HOLLOW STRUCTURAL STEEL
HEIGHT
HEATING, VENTILATING, AND AIR CONDITIONING
HEAVY
HOT WATER
HYDRANT
HYDRAULIC
INDOOR AIR QUALITY
INTERNATIONAL BUILDING CODE
INFECTION CONTROL
INFECTION CONTROL WALL
INSIDE DIAMETER
IDENTIFICATION NUMBER
ILLUMINATION
INCLUDED
INDEPENDENT OR INDUSTRIAL
INFORMATION
INSULATION
INTERIOR
INTERNATIONAL
INSTANTANEOUS WATER HEATER
JANITOR
KILN DRIED OR KNOCKED DOWN
KITCHEN
KNOCKOUT
KICKPLATE
ANGLE
LABORATORY
LADDER
LAMINATE
LAMINATED GLASS
LAUNDRY
LAVATORY
LUMBER
POUND
LOCKABLE CHARTING STATION/MED CABINET
LOAD-BEARING
LEADER
LIGHT EMITTING DIODE
LINEAR FEET (FOOT)
LIBRARY
LINEAR
LIQUID
LOCKER
LOCKER ROOM
LEAD LINED
LIMESTONE
LARGE
LOUVERED ROOF VENT
LIGHT
LIGHT GAGE
LIGHT SWITCH
LIGHTWEIGHT
LIGHTING
LIGHTNING
LOUVERED
LOUVER
LIGHTWEIGHT CONCRETE
LIGHTWEIGHT INSULATING CONCRETE
LAYER
MACHINE
MACHINE ROOM
MAINTENANCE
MANUAL
MATERIAL
MASTER ANTENNA TELEVISION SYSTEM
MAXIMUM
MARKER BOARD
METAL CORNER BEAD
DECK
MECHANICAL ENGINEER
MEASURE
MECHANICAL
MECHANICAL ROOM
MEDICAL, MEDIUM
METHYL ETHYL KETONE
MEMBRANE
MEMORANDUM
MEZZANINE
MILL FINISH
MANUFACTURED
MANUFACTURING
MANUFACTURER
MANUFACTURER'S RECOMMENDATION
MANAGEMENT
MICROPHONE
MIDDLE
MILITARY STANDARD
MINIMUM
MIRROR
MISCELLANEOUS
MITER
MARKER
METAL LATH
MOLDING (MOULDING)
MILLWORK
MILLIMETER
MASONRY OPENING
MODEL, MODIFY OR MODULE
MODIFIED BITUMEN
MONITOR
MOP RACK
MOISTURE RESISTANT
MOP SINK
MOUNTED
MOUNTING
METAL
MULLION
MICROWAVE
MEMBRANE WATERPROOFING
N
NA
NAT
NATL
NC
NCOMBL
NEC
NEG
NEMA
NEUT
NFC
NFPA
NIC
NO
NOM
NR
NRC
NRCA
NRP
NS
NUM
O/O O
OA
OC
OCC
OCT
OD
OD
OF/CI
OFD
OFF
OF/OI
OH
OH DR
OPH
OPNG
OPP
OPR
OPT
OR
ORD
ORG
ORIG
ORN
OSHA
OUT
OZ
P
PAR
PARA
PART
PAT
PB
PBD
PC
PCA
PCC
PCCP
PCD
PCF
PCP
PCT
PED
PEN
PEND
PERF
PERIM
PERP
PHAR
PHOTO
PKG
PL
PL GL
PLAM
PLAS
PLBG
PLYWD
PMTL
PNEU
PNL
PO
POLY
PP
PR
PRCST
PREFAB
PREFIN
PRELIM
PREP
PRESS
PREV
PRKG
PRMLD
PROJ
PROP
PSF
PSI
PT
PTD
PTN
PTS
PVC
PVG
PWR
QA
QC
QRY
QTR
QTY
QUAD
QUAL
R
RA
RAD
RBM
RBR
NORTH
NOT APPLICABLE
NATURAL
NATIONAL
NOISE CRITERIA OR NURSE CALL
NONCOMBUSTIBLE
NATIONAL ELECTRICAL CODE
NEGATIVE
NATIONAL ELECTRICAL MANUFACTURERS ASSN
NEUTRAL
NATIONAL FIRE CODE
NATIONAL FIRE PROTECTION ASSOCIATION
NOT IN CONTRACT
NUMBER
NOMINAL
NOISE REDUCTION
NOISE REDUCTION COEFFICIENT
NATIONAL ROOFING CONTRACTORS ASSOCIATION
NONREMOVABLE
NARROW STILE
NUMERAL
OUT TO OUT
OXYGEN
OUTSIDE AIR OR OVERALL
ON CENTER
OCCUPY
OCTAGON
OUTSIDE DIAMETER, OUTSIDE DIMENSION
OUTSIDE DIAMETER/OUTSIDE DIMENSION
OWNER FURNISHED/CONTRACTOR INSTALLED
OVERFLOW DRAIN
OFFICE
OWNER FURNISHED/OWNER INSTALLED
OVERHANG
OVERHEAD (COILING) DOOR
OPPOSITE HAND
OPENING
OPPOSITE
OPERABLE
OPTIONAL
OPERATING ROOM OR OUTSIDE RADIUS
ORDNANCE OR OVERFLOW ROOF DRAIN
ORGANIC
ORIGINAL
ORNAMENTAL
OCCUPATIONAL SAFETY AND HEALTH ADMINSTRATION
OUTLET
OUNCE
PAINT
PARALLEL OR PARAPET
PARAGRAPH
PARTIAL
PATTERN
PUSHBUTTON
PARTICLEBOARD
PIECE, POLYCARBONATE OR PORTLAND CEMENT
PORTLAND CEMENT ASSOCIATION
PRECAST CONCRETE
CONCRETE PAVEMENT
PAPER CUP DISPENSER
POUNDS PER CUBIC FOOT
PORTLAND CEMENT PLASTER
PRIVACY CURTAIN TRACK
PEDESTAL
PENETRATE
PENDANT
PERFORATED
PERIMETER
PERPENDICULAR
PHARMACY
PHOTOGRAPH
PACKAGE
PROPERTY LINE
PLATE GLASS
PLASTIC LAMINATE
PLASTER OR PLASTIC
PLUMBING
PLYWOOD
PAINTED METAL
PNEUMATIC
PANEL
POST OFFICE, PURCHASE ORDER
POLYETHYLENE (PLASTIC)
PUSH PLATE
PAIR
PRECAST
PREFABRICATE
PREFINISH
PRELIMINARY
PREPARATION
PRESSURE
PREVIOUS
PARKING
PREMOLDED
PROJECT
PROPERTY
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PORCELAIN TILE OR PRESSURE TREATED
PAPER TOWEL DISPENSER
PARTITION
PNEUMATIC TUBE STATION
POLYVINYL CHLORIDE (PLASTIC)
PAVING
POWER
QUALITY ASSURANCE
QUALITY CONTROL
QUARRY
QUARTER
QUANTITY
QUADRANT
QUALITY
RADIUS OR RISER
RETURN AIR
RADIATOR
REINFORCED BRICK MASONRY
RUBBER
RC
RCP
RCVR
RD
REC
RECD
RECPT
RECT
REF
REFR
REG
REINF
REP
REPL
REQ
REQD
RET
REV
RFG
RFI
RFP
RFS
RL
RLG
RM
RM LT
RND
RO
ROW
RS
RSV
RT
RV
RVS
RWL
SA
SALV
SAMP
SAN
SB
SBS
SBSTR
SC
SCH
SCHED
SCHEM
SCP
SCRN
SCT
SCWD
SD
SDG
SECT
SEG
SEL
SEP
SF
SFTWD
SGD
SGL
SHR
SHR HD
SHRD
SHT
SHTHG
SHV
SIM
SJ
SJI
SK
SKLT
SLDG
SLNT
SM
SMK
SND INS
SPEC
SPKLR
SPKR
SPLY
SPR
SQ
SQ IN
SQ YD
SSF
SST
ST
STC
STD
STIF
STL JST
STL LNTL
STL PL
STL RF DK
STL TB
STL TR
STNLS
STOR
STR
STRUCT
STRUCT STL
SUB
SURF
SUSP
SUSP CLG
SW
SWDR
SYM
SYNTH
SYS
REMOTE CONTROL
REFLECTED CEILING PLAN
RECEIVER
ROAD OR ROOF DRAIN
RECESSED
RECEIVED
RECEPTACLE
RECTANGLE
REFERENCE OR REFRIGERATOR
REFRACTORY, REFRIGERATION
REGISTER
REINFORCE
REPAIR
REPLACE
REQUIRE
REQUIRED
RETURN
REVISION
ROOFING
REQUEST FOR INFORMATION
REQUEST FOR PROPOSAL
ROOM FINISH SCHEDULE
ROOF LEADER
RAILING
ROOM
NURSE CALL LIGHT/ROOM LIGHT
ROUND
ROUGH OPENING
RIGHT OF WAY
ROUGH SAWN
RESILIENT SHEET VINYL
RIGHT
ROOF VENT
REVERSE
RAIN WATER LEADER
SUPPLY AIR
SALVAGE
SAMPLE
SANITARY
SPLASH BLOCK
STYRENE BUTADIEN STYRENE
SUBSTRATE
SHARPS CONTAINER
SCHOOL
SCHEDULE
SCHEMATIC
SCUPPER
SCREEN
SHOWER CURTAIN TRACK
SOLID CORE WOOD DOOR
SMOKE DETECTOR/SOAP DISPENSER
SIDING
SECTION
SEGMENT
SELECT
SEPARATE
SQUARE FOOT (FEET)
SOFTWOOD
SLIDING GLASS DOOR
SINGLE
SHOWER
SHOWER HEAD
SHOWER DRAIN
SHEET
SHEATHING
SHELVING
SIMILAR
SCORED JOINT
STEEL JOIST INSTITUTE
SKETCH
SKYLIGHT
SLIDING
SEALANT
SHEET METAL
SMOKE
SOUND INSULATION
SPECIFICATION
SPRINKLER
SPEAKER
SUPPLY
SINGLE PLY ROOF SYSTEM
SQUARE
SQUARE INCH
SQUARE YARD
SOLID SURFACE
STAINLESS STEEL
STAIRS OR STREET
SOUND TRANSMISSION CLASS
STANDARD
STIFFENER
STEEL JOIST
STEEL LINTEL
STEEL PLATE
STEEL ROOF DECK
STEEL TUBE
STEEL TRUSS
STAINLESS
STORAGE
STRINGERS
STRUCTURAL
STRUCTURAL STEEL
SUBSTITUTE
SURFACE
SUSPEND
SUSPENDED CEILING
SWITCH
SWING DOOR
SYMBOL
SYNTHETIC
SYSTEM
T T&M
TB
TBD
TECH
TEL
TEMP
THERM
THK
THRES
THRU
THRUOUT
TMPD
TMPD GL
TN
TO
TO FDN
TOB
TOM
TOP
TOS
TOW
TPD
TRANS
TRTD
TS
TSTAT
TV
TYP
U
UC
UGND
UL
ULT
UNFIN
UNO
UPS
UR
UTIL
UV
VAC
VAR
VEH
VENT
VERT
VEST
VFD
VIC
VID
VIF
VNR
VOC
VOL
VR
VTR
W/ W/O
WBL
WC
WD
WDW
WF
WFR
WFS
WH
WHSE
WP
WPM
WR
WS
WSCT
WT
X BRACE
XPS
YD
TREAD OR THERMOSTAT
TIME AND MATERIALS
TOWEL BAR
TACK BOARD
TECHNICAL
TELEPHONE
TEMPERATURE OR TEMPORARY
THERMAL
THICKNESS
THRESHOLD
THROUGH
THROUGHOUT
TEMPERED
TEMPERED GLASS
TRUE NORTH
TOP OF ___
TOP OF FOUNDATION
TOP OF BEAM
TOP OF MASONRY
TOP OF PARAPET
TOP OF STEEL
TOP OF WALL
TOILET PAPER DISPENSER
TRANSOM
TREATED
TUBE STEEL
THERMOSTAT
TELEVISION
TYPICAL
HEAT TRANSFER COEFFICIENT
UNDERCUT
UNDERGROUND
UNDERWRITERS LABORATORIES
ULTIMATE
UNFINISH
UNLESS NOTED OTHERWISE
UNINTERRUPTIBLE POWER SUPPLY
URINAL
UTILITY
ULTRAVIOLET
VACUUM
VARIES
VEHICLE
VENTILATION
VERTICAL
VESTIBULE
VARIABLE FREQUENCY DRIVE
VICINITY
VIDEO
VERIFY IN FIELD
VENEER
VOLATILE ORGANIC COMPOUND
VOLUME
VAPOR RETARDER
VENT THROUGH ROOF
WITH
WITHOUT
WOOD BLOCKING
WATER CLOSET
WOOD
WINDOW
WIDE FLANGE
WOOD FRAME
WOOD FURRING STRIPS
WATER HEATER
WAREHOUSE
WATERPROOFING
WATERPROOF MEMBRANE
WEATHER RESISTANT
WEATHERSTRIP OR WALL SCONCE
WAINSCOT
WEIGHT OR WINDOW TREATMENT
CROSS BRACE
EXTRUDED POLYSTYRENE BOARD
YARD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSTRUCTION DOCUMENTS
AE PROJECT NUMBER: Dwg. of 78
C U s e rs \m p a rk e r\
D o c u m e n ts
\1
M in n e a p o lis
P h a rm a c y R e n o v a ti o n
R
C e n tr a l m o d e l_ m p a rk e rX U
R A
.r v t
/5
/2
:5
:5
A
M
1361-GI002
ABBREVIATIONS UPGRADE PHARMACY 18
MINNEAPOLIS, MN
618-16-120
06/04/19 LA/BB CD14849 3Revisions: Date:
FLOOR PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL
EXISTING DOOR
AND FRAME TO
REMAIN
DOOR
INTERIOR
BORROWED LIGHT
101B
101A
B3a
XXX
8'-0" DIMENSION LINE,
NOMINAL
8'-0" EXTENDED
DIMENSION LINE,
NOMINAL
AE2111A
INTERIOR
ELEVATION
INDICATOR TAG
2B
AE2O1
EXTERIOR
ELEVATION
INDICATOR TAG
1A
203 EQUIPMENT TAG
100 FLOOR ELEVATIONWALL TAG
OFFICE
ROOM NAME AND
NUMBER AE501
1A
DETAIL REFERENCE
TAG
AE2O1
EXTERIOR SECTION
REFERENCE TAG
1A
AE2O1
INTERIOR SECTION
REFERENCE TAG
1A
KEY NOTE
A
GRIDLINE
REVISION TAG
PR01
REVISION CLOUD
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
FP10
DEMOLITION PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL OR
PARTITION TO BE
REMOVED
EXISTING DOOR
AND FRAME TO
REMAIN
KEY NOTE
A
NEW GRIDLINE
A
EXISTING GRIDLINE
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
EXISTING DOOR
AND FRAME TO BE
DEMOLISHED
DASHED LINE
INDICATES ITEM TO
BE REMOVED (UNO)
DE10
REFLECTED CEILING PLAN
SYMBOLS
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
GBPD
CEILING /
SOFFIT
ACT CEILING
SYSTEM
EXISTING
ACT CEILING
SYSTEM
IV TRACK
CUBICLE
CURTAIN
TRACK
ACCESS
PANEL
2'-0" x 4'-0"
LIGHT FIXTURE
2'-0" x 2'-0"
LIGHT FIXTURE
PENDANT STRIP
LIGHT FIXTURE
PENDANT STRIP
LIGHT FIXTURE
RECESED LIGHT
FIXTURE
MECHANICAL
SUPPLY GRILL
MECHANICAL
RETURN GRILL
WALL SCONCE
LIGHT FIXTURE
MECHANICAL
LINEAR SUPPLY
GRILL
CEILING
ELEVATION AND
FINISH
9'-0" AFF
ACT
PRJ VIDPROJECTOR/DOCUMENT
CAMERA -
WALL/CEILING MOUNT
VIDEO CAMERA
- WALL/CEILING
MOUNT
EXIT SIGN
ACT ACOUSTICAL CEILING TILE
CPT MODULAR CARPET TILE
CT CERAMIC TILE
GYP BD GYPSUM BOARD
LVT LUXURY VINYL TILE
MMA METHYL METHACRYLATE FLOORING
P PAINT
PLAM PLASTIC LAMINATE
PT PORCELAIN TILE (FLOOR AND BASE)
RB RESILIENT BASE
RF RUBBER FLOORING
RWC RIGID VINYL WALL COVERING (WALL PROTECTION)
S SOLID SURFACE
SST STAINLESS STEEL
SC SPECIAL COATING
WSF WELDED SEAM SHEET FLOORING (HEAT WELDED
WITH ROD)
ROOM FINISH LEGEND &
ABBREVIATIONS
MATERIAL INSTALL
DIRECTION
KEYNOTECORNER GUARD
WALL
PROTECTION
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
CG
VCTCPT
AF10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSTRUCTION DOCUMENTS
AE PROJECT NUMBER: Dwg. of 78
C U s e rs \m p a rk e r\
D o c u m e n ts
\1
M in n e a p o lis
P h a rm a c y R e n o v a ti o n
R
C e n tr a l m o d e l_ m p a rk e rX U
R A
.r v t
/5
/2
:5
:5
A
M
1361-GI003
GENERAL NOTES & SYMBOLS UPGRADE PHARMACY 18
MINNEAPOLIS, MN
618-16-120
06/04/19 LA/BB CD14849 4Revisions: Date:
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
2 HOUR FIRE
BARRIER
3 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
3 HOUR FIRE &
SMOKE BARRIER
HE
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EA
EDEXIT EXIT
HORIZONTAL EXIT
EXIT DISCHARGE
EXIT ACCESS
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
LIMITS OF
CONSTRUCTION
SMOKE
COMPARTMENT
BOUNDRY
HEALTH CARE
SUITE
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
OCCUPANCY
SEPERATION
NOYES
APPLICABLE REGULATIONS
GENERAL TYPE OF PROJECT
NFPA NATIONAL FIRE CODES (EXCETION: NFPA 5000 & 900)
2010 FGI GUIDELINES
2015 NFPA 101 (LIFE SAFETY CODE)
ABA STANDARDS (2015) (ABAAS)
2012 IBC
REMODEL
ADDITION
NEW BUILDING
PROJECT DESCRIPTION
CODE SUMMARY
REMODELING OF EXISTING PHARMACY
CURRENTLY CLASSIFIED AS A BUSINESS OCCUPANCY
VA BARRIER FREE DESIGN STANDARD (PG-18-13)
NOYESAUTHORITIES HAVING JURISDICTION (AHJ's)
THE JOINT COMMISSION (TJC)
CENTER FOR MEDICARE/MEDICAID SERVICES (CMS)
NOYES
TESTRATING (HRS)
NOYES
(IBC Chapter 6)
(Section 8.3)
CHANGE OF OCCUPANCY?
FIRE RESISTIVE CORRIDORS?
IBC II-B
(B)
EXTERIOR DOORS AND WINDOWS
SHAFTS AND EXIT PASSAGEWAYS
OTHER
ROOF CONSTRUCTION
PRIME & SEC. FLOOR BEAMS, JOISTS
FLOOR/CEILING ASSEMBLY
FLOOR CONSTRUCTION
INTERIOR
NON-BEARING WALLS AND PARTITIONS
BEARING WALLS
COLUMNS
GIRDERS
TRUSSES
ROOF/CEILING ASSEMBLY
PRIME & SEC. ROOF BEAMS, JOISTS
EXTERIOR
INTERIOR BEARING WALLS
EXTERIOR BEARING WALLS
STRUCTURAL FRAME
SEPARATED OCCUPANCIES?
AREA SEPARATIONS / FIRE WALLS
FIRE BARRIER RATING(S)
SMOKE TIGHT CORRIDORS (SMOKE PARTITIONS)
INCIDENTAL USE AREA RATING(S)
FIRE-RESISTIVE REQUIREMENTS
SEE LIFE SAFETY PLANS
SEE PLANS
OCCUPANCY CLASSIFICATION(S)
TYPE(S) OF CONSTRUCTION
OCCUPANCIES
CONSTRUCTION TYPE(S)
MISCELLANEOUS
(If Remodeling)
2015 LSC (TABLE 6.1.14.1)
SEE LIFE SAFETY PLANS
See Life Safety Plans
AREAS OF REFUGE REQUIRED
MEANS OF EGRESS CAPACITY (width in inches)
EGRESS
20"
1 HR
INTERIOR FINISHES CLASSIFICATION A
NOYES
ACCESSIBLE MEANS OF EGRESS ("MOE") REQUIRED
ELEVATOR REQUIRED AS MEANS OF EGRESS
(LSC CH 12-42)
OSHA STANDARDS
VA SEISMIC DESIGN REQUIREMNTS H-18-8
NATIONAL ELECTRIC CODE (NEC)
ASME BIOLER AND PRESSURE VESSEL CODE
ASME CODE FOR RESSURE PIPING
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,
AMERICAN CONCRETE INSTITTE AND COMENTARY (ACI 318)
MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE
FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL
BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
ENERGY POLICY ACT OF 2005 (EPAct)
DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS
FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE
RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL
BUILDINGS, 10 CFR PARTS 433,434 AND 435
FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE
BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL
ENVIRONMENTAL, ENERGY, AND TRANSPORTATION MANAGEMENT
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED
IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA
MASTER CONSTRUCTION SPECIFICATION
VENTILATION FOR ACCEPTDABLE INDOOR AIR QUALITY -
ASHRAE STANDARD 62.1-2004
SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE
STANDARD 15 -2007
VA FIRE PROTECTION DESIGN MANUAL
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA
NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER
GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)
EXITS
B EXIT ACCESS CORRIDORS
BOTHER SPACES
NFPA II
N/A
N/A
1 HR
1 HR
N/A
2 HR
2 HR
2 HR
N/A
N/A
N/A
USP 97 AND 800 STANDARD
FIRE RESISTIVE BARRIER
DD CC BB Z Y X W V
FDV
FEC
FEC
FEC
SMOKE CONTROL ZONE B-1
SPRINKLER ZONE 18
S M
O K
E C
O N
T R
O L
Z O
N E
B -1
SMOKE CONTROL ZONE B-2
S M
O K
E C
O N
T R
O L
Z O
N E
B -5
SMOKE CONTROL ZONE B-3
SPRINKLER ZONE 5
AA
EXTENT OF EXISTING 2
HOUR FIRE BARRIER HAS
BEEN REDUCED WITHIN
THIS SCOPE OF WORK
TO REDUCE DEAD END
CORRIDOR LENGTH
T R
A V
E L
D
IS
T A
N C
E
TO
TA
L
TR
AV
EL
D
IS
TA
NC
E
DE
AD
E
ND
0'
CO
M
M O
N
PA
TH
O
F
TR
AV
EL
5'
TOTAL TRAVEL DISTANCE = 105'
TRAVEL DISTANCE
FDV
PLAN
NORTH
TRUE
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSTRUCTION DOCUMENTS
AE PROJECT NUMBER:
KEY PLAN
BUILDING 70
Dwg. of 78
C U s e rs \m p a rk e r\
D o c u m e n ts
\1
M in n e a p o lis
P h a rm a c y R e n o v a ti o n
R
C e n tr a l m o d e l_ m p a rk e rX U
R A
.r v t
/5
/2
:5
:5
A
M
1361-GI004
LOWER LEVEL LIFE SAFETY PLAN UPGRADE PHARMACY 18
MINNEAPOLIS, MN
618-16-120
06/04/19 LA CD14849 5
1/8" = 1'-0"
LOWER LEVEL LIFE SAFETY PLAN
0 8' 16'4'
NOYES
APPLICABLE REGULATIONS
GENERAL TYPE OF PROJECT
NFPA NATIONAL FIRE CODES (EXCETION: NFPA 5000 & 900)
2010 FGI GUIDELINES
2015 NFPA 101 (LIFE SAFETY CODE)
ABA STANDARDS (2015) (ABAAS)
2012 IBC
REMODEL
ADDITION
NEW BUILDING
PROJECT DESCRIPTION
CODE SUMMARY
REMODELING OF EXISTING PHARMACY
CURRENTLY CLASSIFIED AS A BUSINESS OCCUPANCY
VA BARRIER FREE DESIGN STANDARD (PG-18-13)
NOYESAUTHORITIES HAVING JURISDICTION (AHJ's)
THE JOINT COMMISSION (TJC)
CENTER FOR MEDICARE/MEDICAID SERVICES (CMS)
NOYES
TESTRATING (HRS)
NOYES
(IBC Chapter 6)
(Section 8.3)
CHANGE OF OCCUPANCY?
FIRE RESISTIVE CORRIDORS?
IBC II-B
(B)
EXTERIOR DOORS AND WINDOWS
SHAFTS AND EXIT PASSAGEWAYS
OTHER
ROOF CONSTRUCTION
PRIME & SEC. FLOOR BEAMS, JOISTS
FLOOR/CEILING ASSEMBLY
FLOOR CONSTRUCTION
INTERIOR
NON-BEARING WALLS AND PARTITIONS
BEARING WALLS
COLUMNS
GIRDERS
TRUSSES
ROOF/CEILING ASSEMBLY
PRIME & SEC. ROOF BEAMS, JOISTS
EXTERIOR
INTERIOR BEARING WALLS
EXTERIOR BEARING WALLS
STRUCTURAL FRAME
SEPARATED OCCUPANCIES?
AREA SEPARATIONS / FIRE WALLS
FIRE BARRIER RATING(S)
SMOKE TIGHT CORRIDORS (SMOKE PARTITIONS)
INCIDENTAL USE AREA RATING(S)
FIRE-RESISTIVE REQUIREMENTS
SEE LIFE SAFETY PLANS
SEE PLANS
OCCUPANCY CLASSIFICATION(S)
TYPE(S) OF CONSTRUCTION
OCCUPANCIES
CONSTRUCTION TYPE(S)
MISCELLANEOUS
(If Remodeling)
2015 LSC (TABLE 6.1.14.1)
SEE LIFE SAFETY PLANS
See Life Safety Plans
AREAS OF REFUGE REQUIRED
MEANS OF EGRESS CAPACITY (width in inches)
EGRESS
20"
1 HR
INTERIOR FINISHES CLASSIFICATION A
NOYES
ACCESSIBLE MEANS OF EGRESS ("MOE") REQUIRED
ELEVATOR REQUIRED AS MEANS OF EGRESS
(LSC CH 12-42)
OSHA STANDARDS
VA SEISMIC DESIGN REQUIREMNTS H-18-8
NATIONAL ELECTRIC CODE (NEC)
ASME BIOLER AND PRESSURE VESSEL CODE
ASME CODE FOR RESSURE PIPING
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,
AMERICAN CONCRETE INSTITTE AND COMENTARY (ACI 318)
MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE
FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL
BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
ENERGY POLICY ACT OF 2005 (EPAct)
DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS
FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE
RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL
BUILDINGS, 10 CFR PARTS 433,434 AND 435
FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE
BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL
ENVIRONMENTAL, ENERGY, AND TRANSPORTATION MANAGEMENT
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED
IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA
MASTER CONSTRUCTION SPECIFICATION
VENTILATION FOR ACCEPTDABLE INDOOR AIR QUALITY -
ASHRAE STANDARD 62.1-2004
SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE
STANDARD 15 -2007
VA FIRE PROTECTION DESIGN MANUAL
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA
NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER
GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)
EXITS
B EXIT ACCESS CORRIDORS
BOTHER SPACES
NFPA II
N/A
N/A
1 HR
1 HR
N/A
2 HR
2 HR
2 HR
N/A
N/A
N/A
USP 97 AND 800 STANDARD
FIRE RESISTIVE BARRIER
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
2 HOUR FIRE
BARRIER
3 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
3 HOUR FIRE &
SMOKE BARRIER
HE
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EA
EDEXIT EXIT
HORIZONTAL EXIT
EXIT DISCHARGE
EXIT ACCESS
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
LIMITS OF
CONSTRUCTION
SMOKE
COMPARTMENT
BOUNDRY
HEALTH CARE
SUITE
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
OCCUPANCY
SEPERATION
SMOKE CONTROL ZONE 3-58
SPRINKLER ZONE 76
CONSTRUCTION LIMITS
PLAN
NORTH
TRUE
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSTRUCTION DOCUMENTS
AE PROJECT NUMBER:
KEY PLAN
BUILDING 70
Dwg. of 78
C U s e rs \m p a rk e r\
D o c u m e n ts
\1
M in n e a p o lis
P h a rm a c y R e n o v a ti o n
R
C e n tr a l m o d e l_ m p a rk e rX U
R A
.r v t
/5
/2
:5
:5
A
M
1361-GI005
THIRD LEVEL LIFE SAFETY PLAN UPGRADE PHARMACY 18
MINNEAPOLIS, MN
618-16-120
06/04/19 LA JT14849 6
1/8" = 1'-0"
THIRD LEVEL LIFE SAFETY PLAN
INFECTION CONTROL GENERAL NOTES
1. THE INTENT OF INFECTION CONTROL ISOLATION IS TO PROTECT PATIENTS IN THE HOSPITAL WHICH HAVE LOW IMMUNE LEVELS. THEREFORE, CONSTRUCTION OPERATIONS NEED TO BE DIRECTED TO CONTAIN DUST AND PARTICULATE MATTER TO THE CONSTRUCTION AREA. CONSTRUCTION AREA PERIMETER NEEDS TO BE SEALED COMPLETELY WITH MIN 4 MIL POLY AND DUCT TAPE DURING CLASS II, III, OR IV OPERATIONS.
2. PROVIDE TRIATEK ISOLATION MONITORS DURING CLASS III OR CLASS IV CONSTRUCTION OPERATIONS. EACH AREA TO BE UNDER NEGATIVE PRESSURE (0.02"WC) DURING THESE OPERATIONS. MONITOR TO MEASURE PRESSURE DIFFERENTIAL BETWEEN CONSTRUCTION AREA AND ADJACENT CORRIDOR OR ROOM AS DIRECTED BY VA R.E.
3. AS CONSTRUCTION PROGRESSES, FROM TYPE D TO TYPE C (SEE SPECIFICATION SECTION "INFECTION CONTROL") AND THEREON, PROVIDE A REQUEST VIA "INFECTION CONTROL CONSTRUCTION PERMIT" TO THE VA INFECTION CONTROL NURSE. UPON AUTHORIZATION, PROCEED TO NEXT TYPE OF CONSTRUCTION. PROVIDE AT LEAST 10
DAYS NOTICE FOR EACH PERMIT.
4. CONSTRUCT IC (INFECTION CONTROL) CONSTRUCTION BARRIER FROM FLOOR TO DECK/FLOOR ABOVE. EXCEPTION.
IF BARRIER IS ADJACENT SMOKE, FIRE, OR EXISTING WALL CONSTRUCTION WHICH WILL NOT BE DEMOLISHED AND TERMINATES TO FLOOR OR DECK ABOVE, THEN CONSTRUCT IC BARRIER FROM FLOOR TO ABOVE CORRIDOR CEILING WITH 4 MIL POLY BEING SEALED ON ALL EDGES: FLOOR, TOP OF WALL, SIDES, AND ALL PENETRATIONS.
SEE DETAILS THIS SHEET.
5. REFER TO 1/GI005 FOR TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION DETAIL. GENERAL CONTRACTOR SHALL PROVIDE NEW CONSTRUCTION ACCESS DOORS AND PROXIMITY CARD READERS AT ALL BARRIERS. MAINTAIN ALL INFECTION CONTROL STANDARDS. CONTROL BARRIERS ARE TO BE INSTALLED AND
REMOVED ONLY BEFORE 7:00 A.M. AND AFTER 8:00 P.M.
6. HVAC CONTRACTOR SHALL ADJUST THE VARIABLE FREQUENCY DRIVES FOR AHU AS NECESSARY PRIOR TO STARTING ANY CONSTRUCTION OR DEMOLITION OPERATIONS TO ENSURE PROPER INFECTION CONTROL MEASURES. ADJUST VFD FOR BALANCING SUPPLY TO MEET INFECTION CONTROL MEASURES AS INDICATED
HEREAFTER.
7. PROVIDE BALANCING DAMPERS IN THE MAIN SUPPLY AND EXHAUST DUCT WORK SERVING THESE AREAS.
TEMPORARILY BALANCE AIR FLOW TO PROVIDE NEGATIVE AIR FLOW IN CONSTRUCTION ZONE AT ALL TIMES AS INDICATED BELOW. DAMPERS TO REMAIN IN DUCT AFTER CONSTRUCTION IS COMPLETE AND IS TO BE SECURED IN
FINAL BALANCING POSITION PRIOR TO TURNING SYSTEM OVER FOR OCCUPANCY.
8. DURING CONSTRUCTION OPERATIONS IN EACH ENCLOSED AREA PROVIDE ISOLATION MONITORS, MINIMUM (1) ONE IN AREAS LESS THAN 1000 SF, (2) TWO MINIMUM IN AREAS BETWEEN 1000 SF AND 5000 SF, AND (3) THREE
FOR AREAS BETWEEN 5000 SF AND 10000 SF.
9. THE CONTRACTOR SHALL PROVIDE ENOUGH NEGATIVE AIR MACHINES TO COMPLETELY EXCHANGE THE REGULATED AREA AIR VOLUME (4) FOUR ACTUAL TIMES PER HOUR. THE COMPETENT PERSON SHALL DETERMINE THE NUMBER OF UNITS NEEDED FOR EACH REGULATED AREA BY DIVIDING THE CUBIC FEET IN THE REGULATED AREA BY (15) FIFTEEN AND THEN DIVIDING THAT RESULT BY THE ACTUAL CUBIC FEET PER MINUTE (CFM) FOR EACH UNIT TO DETERMINE THE NUMBER OF UNITS NEEDED TO EFFECT (4) FOUR AIR CHANGES PER HOUR. PROVIDE A STANDBY
UNIT IN THE EVENT OF MACHINE FAILURE AND/OR EMERGENCY IN AN ADJACENT AREA.
10. PRIOR TO ANY REMOVAL OF SMOKE BARRIER FIRE RATED WALLS, CONSTRUCT NEW SMOKE BARRIER/APPROPRIATE FIRE RATED WALLS PER NEW PLANS OR CONSTRUCT INFECTION CONTROL BARRIER TO ACT AS SMOKE BARRIER..
11. ALL CONSTRUCTION DEBRIS, WASTE, AND TRANSPORTATION OF DEMOLITION ITEMS SHALL BE CONVEYED IN A COVERED DUMPSTER CONTAINER SUCH THAT NO DEBRIS/ITEMS ARE VISIBLE. ALL CONTAINERS SHALL BE TRANSPORTED DOWN THE 'F' BANK FREIGHT ELEVATORS (A DESIGNATED ELEVATOR WILL NOT BE PROVIDED FOR TRANSPORTATION.) A MINIMUM OF ONE RUNOFF MAT ON THE INSIDE AND MINIMUM OF TWO RUNOFF MATS ON THE
OUTSIDE SHALL BE PROVIDED FOR THE CONSTRUCTION ACCESS DOORS.
NON-PATIENT AREAS - ALL BUILDINGS
CONSTRUCTION PROJECT ACTIVITY TYPE - D
PATIENT RISK GROUP - _HIGH_ RISK
CONTROL PROCEDURE CLASS - _IV__
PATIENT AREAS - ALL BUILDINGS
CONSTRUCTION PROJECT ACTIVITY TYPE - D
PATIENT RISK GROUP - _HIGH _ RISK
CONTROL PROCEDURE CLASS - IV
INFECTION CONTROL RISK ASSESSMENT (ICRA) BY PROJECT AREA USE
ICRA LEGEND
INFECTION CONTROL RISK ASSESSMENT
(ICRA) BY PROJECT AREA USE
LEGEND
NON-PATIENT
HOSPITAL AREAS
NO WORK
REFER TO ALL FLOOR PLAN SHEETS , PLUMBING
INSULATION INFORMATION, PLUMBING DEAD LEG
INFORMATION AND PLUMBING KEYNOTES
INFORMATION TABLE FOR DETERMINATION OF
INFECTION CONTROL PROCEDURES REQUIRED
AT EACH BID ITEM.
NEW OR EXISTING CEILING
CONTINUOUS DUCT
TAPE SEAL EACH SIDE
AT CEILING
COMPRESSIBLE
INSULATION
CONTINUOUS DUCT
TAPE SEAL EACH
SIDE
EXISTING FINISHED
FLOOR
(1) LAYER 5/8" GYP BD EACH
SIDE. FINISH OCCUPIED SIDE
WITH GLOSS PAINT
3 5/8" STEEL STUDS @ 16"
OC WITH FULL BATT SOUND
ATTENUATING INSULATION
CONTINUOUS FIRE
RETARDANT TREATED
WOOD NAILER
CLOSE INTERSTITIAL SPACE WITH
6 MIL POLYETHYLENE
BARRIER. SEAL ALL JOINTS,
PENETRATIONS AND ENTIRE
PERIMETER OF BARRIER
WITH CONTINUOUS DUCT TAPE
CLOSE OPEN DUCTS WITH
6 MIL POLYETHYLENE
BARRIER. SEAL EDGES
WITH CONTINUOUS DUCT
TAPE
"WORK" SIDE OF BARRIER OCCUPIED SIDE OF BARRIER
3 5/8" STEEL STUDS @ 16"
OC WITH FULL BATT SOUND
ATTENUATING INSULATION
3 5/8" STEEL STUDS @ 16"
OC WITH FULL BATT SOUND
ATTENUATING INSULATION
COMPRESSIBLE INSULATION
INTERSITIAL BARRIER
SEALANT WITH FOAM
ROD BACKUP
6 MIL POLY OVER
CEILING PENETRATION
NOTES:
1. ALL CORNERS TO FORM 90 ANGLE WITH NO RADIUS
2. SEAL ALL SIDES OF POLY WITH DUCT TAPE
3. SEAL ALL CRACKS WITH DUCT TAPE.
6 MIL POLY OVER
EQUIPMENT OR
FURNISHING
6 MIL POLY OVER
WALL PROTRUSION
FLOOR
DOOR
BEYOND
WINDOW
BEYOND
CEILING
6 MIL POLY OVER
WALL OPENINGS
6 MIL POLY OVER
DOORS & WINDOWS
CEILING
DD CC BB Z Y X W V
AA
PLAN
NORTH
TRUE
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSTRUCTION DOCUMENTS
AE PROJECT NUMBER:
KEY PLAN
BUILDING 70
Dwg. of 78
C U s e rs \m p a rk e r\
D o c u m e n ts
\1
M in n e a p o lis
P h a rm a c y R e n o v a ti o n
R
C e n tr a l m o d e l_ m p a rk e rX U
R A
.r v t
/5
/2
:0
:0
P
M
1361-GI006
INFECTION CONTROL RISK
ASSESSMENT PLAN
UPGRADE PHARMACY 18
MINNEAPOLIS, MN
618-16-120
06/04/19 LA CD14849 7
1/2" = 1'-0"
TYP DUST PROOF BARRIER
12" = 1'-0"
CRITICAL BARRIER PREPARATION / INSTALLATION
1/16" = 1'-0"
LOWER LEVEL INFECTION CONTROL RISK ASSESSMENT PLAN
0 16' 32'8' 1/16" = 1'-0"
THIRD LEVEL INFECTION CONTROL RISK
ASSESSMENT PLAN
0 16' 32'8'
PHASE 1B
PHASE 5
PHASE 7
PHASE 6
PHASE 3
PHASE 1A
PROVIDE SECURE
TEMPORARY
CONSTRUCTION
ENTRANCE FOR
PHASE 5
PROVIDE SECURE TEMPORARY
CONSTRUCTION ENTRANCE FOR
PHASE 1A
PROVIDE SECURE TEMPORARY
CONSTRUCTION ENTRANCE FOR
PHASE 1A & 1B
PROVIDE SECURE TEMPORARY
CONSTRUCTION ENTRANCE FOR
PHASE 1C, 2, 3, 4, AND 6
BC-67
CORRIDOR
PHASE 2
PHASE 4
CONSTRUCTION PHASING
DESCRIPTION
1A- MEN'S TOILET, CBOC, RECEIVING, STORAGE HD DRUGS, HD BUFFER
ROOM, AND PORTION OF GENERAL PHARMACY
1B- ANTEROOM, NON HD BUFFER ROOM, MECH ROOM, OFFICE BR-111B, AND
PORTION OF GENERAL PHARMACY
UPON THE RECEIPT OF THE NOTICE TO PROCEED AND PRIOR TO THE START
OF PHASE 2, THE CONTRACTOR SHALL CONSTRUCT TEMPORARY BARRIERS,
START DEMOLITION AND COMPLETE ALL CONTRACTUAL WORK INVOLVED IN
PHASE 1 AREAS INCLUDING ALL TEMPORARY SIGNAGE TO DIRECT
(VETERANS, PATIENT, PEDESTRIAN) FLOW.
PHASE 1A WORK WILL BEGIN FIRST HOWEVER THE TIMING OF PHASES 1B
WORK WILL COORDINATE BETWEEN THE CONTRACTOR AND VA COR, PHASES
1A & 1B WORK IS REQUIRED TO BE SUBSTANTIALLY COMPLETE AND READY
FOR OCCUPANCY PRIOR TO NOV. 1 2019. THE REMAINING PHASE OF WORK
SHALL BE SUBSTANTIALLY COMPLETE AND READY FOR OCCUPANCY AT TIME
OF SUBSTANTIAL COMPLETION FOR EACH PHASE OF WORK.
PHASE 1.
WOMEN 'S TOILET, BULK STORAGE, AND GENERAL PICKING
UPON OWNER INSPECTION AND APPROVAL OF PHASE 2 AND PRIOR TO THE
START OF PHASE 3, THE CONTRACTOR SHALL CONSTRUCT TEMPORARY
BARRIERS, START DEMOLITION AND COMPLETE ALL CONTRACTUAL WORK
INVOLVED IN PHASE 3 AREAS INCLUDING ALL TEMPORARY PROVISIONS AND
SIGNAGE
PHASE 3.
PORTION OF GENERAL PICKING, BULK STORAGE, UNIT DOSE, AND
REMAINDER OF GENERAL PHARMACY
UPON OWNER INSPECTION AND APPROVAL OF PHASE 3 AND PRIOR TO THE
START OF PHASE 4, THE CONTRACTOR SHALL CONSTRUCT TEMPORARY
BARRIERS, START DEMOLITION AND COMPLETE ALL CONTRACTUAL WORK
INVOLVED IN PHASE 4 AREAS INCLUDING ALL TEMPORARY PROVISIONS AND
SIGNAGE
PHASE 4.
PICK-UP WINDOW, HSKG, STAFF LOUNGE, CONFERENCE/TRAINING ROOM,
WORK STATIONS, CORRIDOR EXTENSIONS, ROOM BR-110A, BR-110B, AND
BR-111
UPON OWNER INSPECTION AND APPROVAL OF PHASE 4 AND PRIOR TO THE
START OF PHASE 5, THE CONTRACTOR SHALL CONSTRUCT TEMPORARY
BARRIERS, START DEMOLITION AND COMPLETE ALL CONTRACTUAL WORK
INVOLVED IN PHASE 5 AREAS INCLUDING ALL TEMPORARY PROVISIONS AND
SIGNAGE
PHASE 5.
ADMINISTRATIVE OFFICES
UPON OWNER INSPECTION AND APPROVAL OF PHASE 5 AND PRIOR TO THE
START OF PHASE 6, THE CONTRACTOR SHALL CONSTRUCT TEMPORARY
BARRIERS, START DEMOLITION AND COMPLETE ALL CONTRACTUAL WORK
INVOLVED IN PHASE 6 AREAS INCLUDING ALL TEMPORARY PROVISIONS AND
SIGNAGE
PHASE 6.
INVESTIGATIONAL DRUG SERVICES
UPON OWNER INSPECTION AND APPROVAL OF PHASE 6 AND PRIOR TO THE
START OF PHASE 7, THE CONTRACTOR SHALL CONSTRUCT TEMPORARY
BARRIERS, START DEMOLITION AND COMPLETE ALL CONTRACTUAL WORK
INCLUDING ALL TEMPORARY PROVISIONS AND SIGNAGE
PHASE 7.
PHARMACY, PATIENT TOILET & OFFICE
WORK ON THIRD FLOOR SHOULD BE SCHEDULED TO FOLLOW THE PHASED-
WORK ON THE LOWER LEVEL ONCE COMPLETED AND INSPECTED. THE
CONTRACTOR SHALL CONSTRUCT TEMPORARY BARRIERS, START
DEMOLITION AND COMPLETE ALL CONTRACTUAL WORK INCLUDING ALL
TEMPORARY PROVISIONS AND SIGNAGE
THIRD FLOOR.
PHASE 2. INPATIENT NARCOTICS VAULT
UPON OWNER INSPECTION AND APPROVAL OF PHASE 1 AND PRIOR TO THE
START OF PHASE 2, THE CONTRACTOR SHALL CONSTRUCT TEMPORARY
BARRIERS, START DEMOLITION AND COMPLETE ALL CONTRACTUAL WORK
INVOLVED IN PHASE 3 AREAS INCLUDING ALL TEMPORARY PROVISIONS AND
SIGNAGE
CONSTRUCTION PHASING
GENERAL NOTES
1. THE WORK UNDER THIS CONTRACT SHALL BE
DIVIDED INTO PHASES. A PHASE CAN
INVOLVE MULTIPLE LOCATION AREAS.
2. THE GENERAL CONTRACTOR SHALL COORDINATE
ALL PHASING AND SEQUENCING WITH ALL
TRADES AND THE OWNER. THE GENERAL CONTRACTOR
SHALL PROVIDE A WRITTEN NARRATIVE TO OUTLINE
CONSTRUCTION PHASING AND SEQUENCE PLANS, VALIDATING
AND ELABORATING ON THIS PHASING DESCRIPTION.
3. THE GENERAL CONTRACTOR SHALL COOPERATE
FULLY WITH THE OWNER SO WORK MAY BE
CARRIED OUT SMOOTHLY, WITHOUT
INTERFERING WITH OR DELAYING WORK UNDER
THIS CONTRACT, OR OTHER CONTRACTS ON THE
PROJECT SITE OR WORK BY OWNER.
4. THE GENERAL CONTRACTOR'S CONSTRUCTION
SCHEDULE SHALL INDICATE THE SEQUENCE,
COMMENCEMENT AND COMPLETION DATES,
OWNER INSPECTION AND APPROVAL DATES
AND MOVE-OUT AND MOVE-IN DATES OF OWNER'S
PERSONNEL FOR ALL PHASES OF THE WORK.
5. THE GENERAL CONTRACTOR SHALL PERFORM
THE WORK IN EACH PHASE IN THE SEQUENCE
SHOWN ON THE PHASING PLAN (DRAWING
1/GI005) AND CONSTRUCTION PHASING
DESCRIPTION.
6. THE GENERAL CONTRACTOR MUST COMPLETE
ALL WORK IN EACH PHASE WITH THE VA
INSPECTING AND ACCEPTING THE WORK PRIOR
TO VA OCCUPANCY AND THE CONTRACTOR
PROCEEDING TO THE NEXT SCHEDULED PHASE. UPON
COMPLETION OF A PARTICULAR PHASE, THE ENTIRE AREA
COVERED BY THAT PHASE CAN BE OCCUPIED BY THE VA
PERSONNEL WITH ALL SYSTEMS FUNCTIONING PROPERLY.
7. BEFORE COMMENCING WORK ON EACH
SUCCESSIVE PHASE, THE GENERAL
CONTRACTOR SHALL SUBMIT AN UPDATED
COPY OF THE SCHEDULE.
8. ANY DUST PARTITIONS CONSTRUCTED BY
THE CONTRACTOR PRIOR TO THE START OF
DEMOLITION MUST REMAIN IN PLACE UNTIL THE
COMPLETION OF THAT PHASE OR
SUBSEQUENT PHASE WHERE REQUIRED.
9. THE CONTRACTOR SHALL PERFORM ALL WORK
ADJACENT TO VA OCCUPIED AREAS IN SUCH A
MANNER TO ENSURE THE CONTINUOUS AND
UNINTERRUPTED USE OF ALL OCCUPIED AREAS,
INCLUDING THE APPLICABLE MECHANICAL AND
ELECTRICAL SYSTEMS SERVING THESE AREAS.
10. FOR ADDITIONAL NOTES AND INFORMATION
REFER TO INFECTION CONTROL DRAWING
GI006 & DEMOLITION PLANS.
11. ANY INFORMATION REGARDING SEQUENCING
PROVIDED IN THE DOCUMENTS IS FOR
ARCHITECT-OWNER PLANNING PURPOSES ONLY.
12. THE CONTRACTOR DURING CONSTRUCTION SHALL MAINTAIN
REQUIRED MEANS OF EGRESS THROUGHOUT ALL PHASING.
13. THE CONTRACTOR SHALL PLAN FOR A MINIMUM OF 4 WEEKS' TIME
BETWEEN PHASES TO ALLOW THE VA TO OCCUPY THE NEWLY
ACCEPTED SPACE AND VACATE THE FOLLOW-ON PHASES. THE VA
WILL ACCELERATE THIS TIME WHEN POSSIBLE AND WILL NOTIFY
THE CONTRACTOR IF THIS OCCURS. SEE SPECIFICATIONS SECTION
01 00 00 1.6.G PHASING.
SCOPE OF WORK DESCRIPTION
THE PROJECT INCLUDES THE LOWER LEVEL IP PHARMACY WORK IN ROOMS: BC-67,
BR-101, BR-101A THOUGH H, BR110A, BR-110B, BR-111 THROUGH BR-117, BR-118,
BR-118A, B&C, BR-119 THROUGH BR-128, BA-111, BA-112, BQ-110d, BQ-110e, BT-102 &
BT-104 ON THE LOWER LEVEL AND INTERSTITIAL SPACE ABOVE.
THE PROJECT ALSO INCLUDES THE HEM/ONC PHARMACY WORK IN ROOMS: C3-49,
C3-52, 3F-117, 3F-117A&B, 3F-120, 3F-120A, 3F-122a, 3F-122b, AND 3F-125 ON THE THIRD
LEVEL AND INTERSTITIAL SPACE ABOVE AND BELOW THE THIRD LEVEL.
THE PROJECT ALSO INCLUDES WORK IN ROOM 5N-101 ALONG WITH THE NORTH WING
OF THE PENTHOUSE (NEAR SHAFT #2) AND CENTER PENTHOUSE (NEAR SHAFT #7)
AND WITHIN THE ENTIRE LENGTH INSIDE OF SHAFT #7 ON THE FIFTH/ PENTHOUSE
LEVEL.
PLAN
NORTH
TRUE
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
CONSTRUCTION DOCUMENTS
AE PROJECT NUMBER:
KEY PLAN
BUILDING 70
Dwg. of 78
C U s e rs \m p a rk e r\
D o c u m e n ts
\1
M in n e a p o lis
P h a rm a c y R e n o v a ti o n
R
C e n tr a l m o d e l_ m p a rk e rX U
R A
.r v t
/5
/2
:0
:0
P
M
1361-GI007
CONSTRUCTION PHASING PLAN UPGRADE PHARMACY 18
MINNEAPOLIS, MN
618-16-120
06/04/19 LA/BB CD14849 8
1/8" = 1'-0"
CONSTRUCTION PHASING PLAN NEW
BR-102
BR-101
BR-104BR-103
BR-113ABR-113B
BR-117BR-117B
BR-117A
BR-108
BR-118
CB79CB81
CB78
CB16
BR-115 BR-114 BR-116
BR-118A
BR-113
BR-129
BR-128
BR-126 BR-127
BR-125
BR-123 BR-124
BR-82
BR-120BR-121
BR-119
BR-119A
BR-122
BR-122A
BR-130
BR-131
DE17
DE12
DE4
DE5
DE4
DE4
DE1
DE3
DE19
DE15DE8 DE9
DE8 DE9
DE10
DE8
DE5
DE1
DE1DE1
DE1 DE1
DE1
DE2
DE2
DE2 DE4DE2
DE2
DE4DE2
DE6
DE8
DE14
DE14
DE4
DE4
DE4
DE4
DE4
DE4
DE4
DE4
DE4
DE4 DE11
DE11
DE5 DE5DE5
DE5
DE5
DE5
DE5
DE5 DE5
DE5
DE5
DE5
DE5
DE5
DE4
DE5
DE5
DE5
DE5
DE5DE4
DE2
DE4DE4DE4
DD CC BB Z Y X W V
DE10
DE2
DE10
DE10
DE10
DE16
DE4
DE2
DE5
DE20
DE4 DE5
4'- 0"
LIMIT OF
DEMOLITION
DE12
DE5DE4
DE5
DE2
DE2
DE16
DE5DE4
DE21
DE18 DE4
DE5
DE4 DE5
DE4
DE5
AA
DE1
DE1
DE7
DE3
DE25
DE4
DE7
DE23
DE24
DE2 DE6
DE7
TYP.
DE29
DE7
DE1
DE1
DE7
DE22
DE25
DE26DE27
DE26DE27
DE26DE27
DE26
DE27
DE26
DE27
DE26
DE2
DE28
DE1
DE2
DE3
DE1
DE3
DE3
DE2
DE6
DE6
DE17
DE30
DE22
DE34
DE34
DE31
DE33
DE35
DE3
DEMOLITION PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
DE1 REMOVE AND DISPOSE OF DOOR AND FRAME, INCLUDING HARDWARE.
DE2 REMOVE AND DISPOSE OF EXISTING FRAMED WALL PARTITIONS, INCLUDE
INSULATION, BRACING, AND WALL FINISHES.
DE3 REMOVE AND DISPOSE OF PORTION OF WALL AS REQUIRED FOR
INSTALLATION OF DOOR AND FRAME OR OPENING.
DE4 REMOVE AND DISPOSE OF SUSPENDED 2X4 ACOUSTICAL TILE CEILING IN
THIS AREA.
DE5 REMOVE ALL EXISTING FLOOR FINISHES TO EXISTING SLAB AND PREP FOR
NEW FLOORING.
DE6 REMOVE AND DISPOSE OF PARTITIONS, DOOR, AND WINDOWS.
DE7 PROVIDE TEMPORARY SUPPORT OF EXISTING CONSTRUCTION AT
LOCATION OF REMOVED PARTITION/WINDOW/DOOR FRAME.
DE8 REMOVE WALL TILES FROM PARTITION TO REMAIN AND PREPARE
SURFACE FOR FINISH
DE9 REMOVE FLOOR TILE, LEVEL SUBSTRATE AND PREPARE SURFACE FOR
FINISH
DE10 REMOVE AND DISPOSE OF EXISTING PLUMBING FIXTURE.
DE11 REMOVE LOCKERS
DE12 REMOVE DUMBWAITER AND SHAFT CONSTRUCTION TO ABOVE THE
INTERSTITIAL SPACE. CAP BOTTOM OF SHAFT.
DE13 REMOVE SUSPENDED GYP BD CEILING IN THIS AREA.
DE14 REMOVE GRAB BARS AND ALL TOILET ACCESSORIES.
DE15 REMOVE FLOOR SINK
DE16 REMOVE SINK AND PREP WALL FOR FINISHES
DE17 REMOVE PORTION OF EXISTING PARTITION AS REQUIRED FOR
MECHANICAL, PLUMBING AND/OR ELECTRICAL.
DE18 REMOVE PORTION OF EXISTING GYP BD CEILING THIS AREA AS REQUIRED
FOR PARTITIONS, MECHANICAL, AND ELECTRICAL.
DE19 REMOVE FIXTURE AND SALVAGE FOR REINSTALLATION
DE20 REMOVE EXISTING HANDRAIL.
DE21 REMOVE AND DISPOSE OF EXISTING MILLWORK.
DE22 REMOVE EXISTING CABINETS AND/OR SHELVING
DE23 REMOVE H.M. FRAME AND GLAZING.
DE24 REMOVE PNEUMATIC SYSTEM AND SALVAGE FOR REINSTALLATION.
DE25 MECH TO RELOCATE FDV -SEE MECH DRAWINGS.
DE26 SAWCUT CONCRETE SLAB TO REMOVE EXISTING PIPING. SEE 1/PD101.
DE27 SAWCUT CONCRETE SLAB AS REQUIRED TO INSTALL PLUMBING. SEE
1/P101.
DE28 REMOVE VAULT DOOR.
DE29 REMOVE EXISTING DAY GATE IN PREPARATION FOR NEW VAULT DOOR &
DAYGATE.
DE30 REMOVE EXISTING SHOWER BASE AND WALL TILE.
DE31 REMOVE PORTION OF FURRED PARTITION TO INSTALL FEC.
DE32 REMOVE EXISTING DOOR AND HM FRAME AND SALVAGE FRAME FOR
RE-USE.
DE33 REMOVE AREA OF RAISED CONCRETE HOUSEKEEPING CURB
CONSTRUCTION. VERIFY EXTENT.
DE34 REMOVE PLUMBING WALL SEE MECHANICAL DRAWING.
DE35 REMOVE EXISTING PASS-THRU.
DEMOLITION GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
GENERAL CONTRACTOR SHALL COORDINATE ALL DEMOLITION WORK, PHASING AND SEQUENCING
WITH THE OWNER. ANY INFORMATION REGARDING SEQUENCING PROVIDED IN THESE DOCUMENTS
IS FOR ARCHITECT - OWNER PLANNING PURPOSES ONLY, UNLESS NOTED OTHERWISE.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH ALL TRADES FOR THE
DEMOLITION WORK REQUIRED FOR THIS PROJECT.
WHERE PARTITIONS ARE INDICATED TO BE REMOVED, REMOVE PARTITION ALONG WITH ALL ITEMS
CONTAINED WITHIN, INCLUDING DOORS, FRAMES, HARDWARE, SIDELIGHTS, WINDOWS,
MECHANICAL AND ELECTRICAL EQUIPMENT, ETC. TO STRUCTURE ABOVE, UNLESS NOTED
OTHERWISE.
WHERE FLOOR FINISH IS INDICATED TO BE DEMOLISHED, REMOVE FINISH TO FLOOR SLAB AS
REQUIRED AND PREPARE SLAB SURFACE FOR SCHEDULED FINISHES WITHIN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.