Specs_087100 Door Hardware LNC Maintenance.pdf

PDF 77 KB Posted

Attached to
Y1AZ--897CM3024 Leavenworth NC - New Maintenance Bldgs (VA-25-00085860)
Solicitation number
36C78625B0043
Issued by

About this file

This document is a Door Hardware specification for the Leavenworth National Cemetery Maintenance Building VA Project 897CM3024. The specification provides detailed requirements for door hardware installation, including hinges, continuous hinges, door closers, stops, locks, electric strikes, and access control components. The document covers multiple hardware sets for various doors, specifying exact hardware types, manufacturers, finishes, and installation requirements.

Key technical specifications include compliance with ANSI/BHMA standards, use of Grade 1 hardware, and detailed installation instructions. The hardware sets include a mix of mechanical and electronic access solutions, with some doors featuring card readers, electric strikes, and security keypads. Specific hardware manufacturers mentioned include McKinney, Pemko, Rockwood, ASSA ABLOY, BEST Locks & Closers, HES, Rixson, Norton, and Securitron. The specification emphasizes accessibility, fire safety compliance, and secure access control for different areas of the maintenance building.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Leavenworth National Cemetery VA Project 897CM3024

Maintenance Building Bid Documents (Addendum 01)

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 1

SECTION 08 71 00

DOOR HARDWARE

PART 1 - GENERAL

1.1 DESCRIPTION

A. Door hardware and related items necessary for complete installation and operation of doors.

1.2 RELATED WORK

A. Caulking: Section 07 92 00, JOINT SEALANTS.

B. Application of Hardware: Section 08 11 13, HOLLOW METAL DOORS AND

FRAMES, Section 08 41 13, ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS, and Section 08 33 00, COILING DOORS AND GRILLES.

C. Painting: Section 09 91 00, PAINTING.

D. Electrical: Division 26, ELECTRICAL.

1.3 GENERAL

A. All hardware must comply with UFAS, (Uniform Federal Accessible

Standards) unless specified otherwise.

B. Provide rated door hardware assemblies where required by most current version of the International Building Code (IBC).

C. Hardware for Labeled Fire Doors and Exit Doors: Conform to requirements of NFPA 80 for labeled fire doors and to NFPA 101 for exit doors, as well as to other requirements specified. Provide hardware listed by UL, except where heavier materials, large size, or better grades are specified herein under paragraph HARDWARE SETS. Instead of UL labeling and listing, test reports from a nationally recognized testing agency may be submitted showing that hardware has been tested in accordance with UL test methods and that

D. Make hardware for application on metal and wood doors and frames to standard templates. Furnish templates to the fabricator of these items in sufficient time so as not to delay the construction.

E. The following items to be of the same manufacturer, if possible, except as otherwise specified:

1. Mortise locksets.

2. Hinges for hollow metal and wood doors.

3. Surface applied overhead door closers.

4. Exit devices.

1.4 SUSTAINABILITY REQUIREMENTS

A. Materials in this section may contribute towards contract compliance with sustainability requirements. See Section 01 81 13, SUSTAINABLE

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 2

CONSTRUCTION REQUIRMENTS, for project local/regional materials, low-emitting materials, and recycled content requirements.

1.5 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA

AND SAMPLES.

B. Hardware Schedule: Prepare and submit hardware schedule in the following form:

Hardware

Item

Quantity Size Reference

Publication

Type No.

Finish Mfr. Name and Catalog

No.

Key

Control

Symbols

UL Mark

(if fire rated and listed)

ANSI/BHMA

Finish

Designation

C. Samples and Manufacturers' Literature:

1. Samples: All hardware items (proposed for the project) that have not been previously approved by Builders Hardware Manufacturers

Association must be submitted for approval. Tag and mark all items with manufacturer's name, catalog number and project number.

2. Samples are not required for hardware listed in the specifications by manufacturer's catalog number, if the contractor proposes to use the manufacturer's product specified.

D. Certificate of Compliance and Test Reports: Submit certificates that hardware conforms to the requirements specified herein. Certificates must be accompanied by copies of reports as referenced. The testing must have been conducted in the manufacturer's plant and certified by an independent testing laboratory or conducted in an independent laboratory, within four years of submittal of reports for approval.

1.6 DELIVERY AND MARKING

A. Deliver items of hardware to job site in their original containers, complete with necessary appurtenances including screws, keys, and instructions. Tag one of each different item of hardware and deliver to

COR for reference purposes. Tag must identify items by Project

Specification number and manufacturer's catalog number. These items will remain on file in COR's office until all other similar items have been installed in project, at which time the COR will deliver items on file to Contractor for installation in predetermined locations on the project.

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 3

1.7 INSTRUCTIONS

A. Hardware Set Symbols on Drawings: Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated on drawings by symbols.

Symbols for hardware sets consist of letters "HW" followed by a number.

Each number designates a set of hardware items applicable to a door type.

B. Keying: Key cylinders into existing Great Grand Master Key System.

Provide removable core cylinders that are removable only with a special key or tool without disassembly of knob or lockset. Provide 7 pin type cylinders. Keying information will be furnished at a later date by the

COR.

1.8 APPLICABLE PUBLICATIONS

A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by the basic designation only. Comply with applicable provisions and recommendations of the following, except as otherwise shown or specified.

B. American National Standards Institute/Builders Hardware Manufacturers

Association (ANSI/BHMA):

A156.1-13 Butts and Hinges

A156.11-2019 Bored and Pre-assembled Locks and Latches

A156.3-2020 Exit Devices

A156.4-2019 Door Controls (Closers)

A156.5-10 Auxiliary Locks and Associated Products

A156.6-2021 Architectural Door Trim

A156.8-2021 Door Controls-Overhead Stops and Holders

A156.13-2017 Mortise Locks and Latches

A156.15-2021 Release Devices-Closer Holder, Electromagnetic and Electromechanical

A156.16-02 American National Standard for Auxiliary

Hardware

A156.18-2020 Materials and Finishes

A156.21-09 Thresholds

A156.22-12 Door Gasketing and Edge Seal Systems

A156.23-2017 Electromagnetic Locks

A156.24-2018 Delayed Egress Locking Systems

A156.26-2021 Continuous Hinges

A156.31-2019 Electric Strikes and Frame Mounted Actuators

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 4

C. American Society for Testing and Materials (ASTM):

F883-13(2022) Padlocks

D. Builders Hardware Manufacturers Association (BHMA):

Certified Products Directory 2014

E. National Fire Protection Association (NFPA):

80-22 Fire Doors and Fire Windows

101-24 Life Safety Code

F. Underwriters Laboratories, Inc. (UL):

Building Materials Directory

PART 2 - PRODUCTS

2.1 BUTT HINGES

A. ANSI A156.1. Provide the following types of butt hinges for the types of doors listed, except where otherwise specified:

1. Exterior Doors: Type A2112 for doors 900 mm (3 feet) wide or less and Type A2111 for doors over 900 mm (3 feet) wide. Provide hinges for exterior doors with non-removable pins.

2. Interior Doors: Type 8112 for doors 900 mm (3 feet) wide or less and

Type A8111 for doors over 900 mm (3 feet) wide.

B. See Articles "MISCELLANEOUS HARDWARE" and "HARDWARE SETS" for pivots and hinges other than butts specified above and continuous hinges specified below.

2.2 CONTINUOUS HINGES

A. Continuous, Gear-Type Hinges: Extruded-aluminum, pin-less, geared hinge leaves; joined by a continuous extruded-aluminum channel cap; with concealed, self-lubricating thrust bearings.

1. Manufacturers:

a. Bommer Industries, Inc.

b. Hager Companies.

c. McKinney Products Company; an ASSA ABLOY Group company.

d. Pemko Manufacturing Co.

e. Select Products Limited.

f. Zero International.

B. ANSI/BHMA A156.26, Grade 1-600.

1. Listed under Category N in BHMA's "Certified Product Directory."

2.3 DOOR CLOSING DEVICES

A. Provide closing devices of one manufacturer for each type specified.

2.4 OVERHEAD CLOSERS

A. Conform to ANSI A156.4, Grade 1 and the following:

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 5

1. 50 percent adjustable closing force over minimum value for that closer and have adjustable hydraulic back check effective between 60 degrees and 85 degrees of door opening.

2. Hold-open feature, where specified.

3. Size Requirements: Size closers in accordance with manufacturer’s recommendations or provide multi-size closers, sizes 1 through 6.

4. Material of closer must be cast aluminum.

5. Steel or malleable iron arm and brackets.

6. Provide with full size cover.

7. Adjustable hydraulic back-check and separate valves for closing and latching speed.

2.5 DOOR STOPS

A. Conform to ANSI A156.16.

B. Provide door stops wherever an opened door or any item of hardware thereon would strike a wall, column, equipment or other parts of building construction. For concrete, masonry or quarry tile construction, use lead expansion shields for mounting door stops.

C. Where cylindrical locks with turn pieces or pushbuttons occur, equip wall bumpers Type L02251 (rubber pads having concave face) to receive turn piece or button.

D. Substitute floor stops Type L02141 or L02161 as appropriate, when wall bumpers would not provide an effective door stop.

E. Where drywall partitions occur, use floor stops, Type L02141 or L02161.

F. Provide stop Type L02011 or L02181, as applicable for exterior doors.

G. Provide appropriate roller bumper for each set of doors (except where closet doors occur) where two doors would interfere with each other in swinging.

H. Provide appropriate door mounted stop on doors in individual toilets where floor or wall mounted stops cannot be used.

2.6 FLOOR DOOR HOLDERS

A. Conform to ANSI Standard A156.16. Provide extension strikes for Types

L01301 and L01311 holders where necessary.

2.7 LOCKS AND LATCHES

A. Conform to ANSI A156.2. Locks and latches for doors 45 mm (1-3/4 inch) thick or over must have beveled fronts. Lock cylinders must have not less than seven pins. Cylinders for all locksets to be removable core type. Provide cylinders with construction removable cores and construction master keys. Cylinder to be removable by special key or

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 6 tool. Construct all cores so that they will be interchangeable into the core housings of all mortise locks, rim locks, cylindrical locks, and any other type lock included in the Great Grand Master Key System.

Lever or lockset must not require disassembly to remove core from lockset. All locksets or latches on double doors with fire label to have latch bolt with 19 mm (3/4 inch) throw. Provide temporary keying device or construction core of allow opening and closing during construction and prior to the installation of final cores.

B. In addition, locks and latches must comply with following requirements:

1. Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13; Series

1000, minimum Grade 2. Locks and latchsets to be furnished with curved lip strike and wrought box. Lock function F02 to be furnished with emergency tools/keys for emergency entrance. Furnish armored fronts for all mortise locks. Where mortise locks are installed in high-humidity locations or where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.

2. Cylindrical Lock and Latch Sets: Levers must meet ADA (Americans with Disabilities Act) requirements. Cylindrical locksets to be series 4000 Grade I. Knobs for series 4000 lock and latch sets to have 57 mm (2-1/4 inch) diameters. Where two turn pieces are specified for lock F76, turn piece on inside knob must lock and unlock inside knob, and turn piece on outside knob must unlock outside knob when inside knob is in the locked position. (This function is intended to allow emergency entry into these rooms without an emergency key or any special tool.)

3. Auxiliary locks specified under hardware sets must conform to ANSI

A156.5.

2.8 ELECTROMAGNETIC LOCKS

A. ANSI/BHMA A156.23; electrically powered, of strength and configuration indicated; with electromagnet attached to frame and armature plate attached to door. Listed under Category E in BHMA's "Certified Product

Directory."

1. Type: Full exterior or full interior, as required by application indicated.

2. Strength Ranking: 1000 lbf.

3. Inductive Kickback Peak Voltage: Not more than 53 V.

4. Residual Magnetism: Not more than 4 lbf to separate door from magnet.

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 7

B. Delayed-Egress Locks: BHMA A156.24. Listed under Category G in BHMA's

"Certified Product Directory".

1. Means of Egress Doors: Lock releases within 15 seconds after applying a force not more than 15 lbf for not more than 3 seconds, as required by NFPA 101.

2. Security Grade: Activated from secure side of door by initiating device.

3. Movement Grade: Activated by door movement as initiating device.

4. Lock housing must not project more than 4-inches (101mm) from the underside of the frame head stop.

2.9 ELECTRIC STRIKES

A. ANSI/ BHMA A156.31 Grade 1.

B. General: Use fail-secure electric strikes at fire-rated doors.

2.10 KEYS

A. Stamp all keys with change number and key set symbol. Furnish keys in quantities as follows:

Locks/Keys Quantity

Cylinder locks 2 keys each

Cylinder lock change key blanks

10 each different key way

Master-keyed sets 6 keys each

Grand Master sets 6 keys each

Great Grand Master set 5 keys

Control key 1 key

2.11 KICK-MOP PLATES

A. Conform to ANSI Standard A156.6.

B. Provide protective plates and door edging as specified below:

1. Kick-mop plates and armor plates to be metal, Type J100 series, color as required.

2. Provide kick-mop plates for both sides of each door, except where noted as not required. Kick-mop plates to be 200 mm (8 inches) high.

On push side of doors where jamb stop extends to floor, make combination kick-mop plates 38 mm (1-1/2 inches) less than width of door, except pairs of metal doors to have plates 25 mm (1 inch) less than width of each door. Extend all other combination kick-mop plates to within 6 mm (1/4 inch) of each edge of doors. Kick mop

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 8 plates to butt astragals. For jamb stop requirements, see specification sections pertaining to door frames.

3. Kick-mop plates are not required on following door sides:

a. Exterior side of exterior doors;

b. Closet side of closet doors;

c. Storage side of doors to or from storage spaces; and

d. Both sides of aluminum entrance doors.

2.12 EXIT DEVICES

A. Conform to ANSI Standard A156.3, Grade 1; type and function are specified in hardware sets. Provide flush with finished floor strikes for vertical rod exit devices in interior of building. Trim to have lever handles similar to locksets, unless otherwise specified.

B. Exit devices for fire doors must comply with Underwriters Laboratories, Inc., requirements for Fire Exit Hardware. Submit proof of compliance.

2.13 FLUSH BOLTS (LEVER EXTENSION)

A. Conform to ANSI A156.16, Type L24081 unless otherwise specified.

Furnish proper dustproof strikes conforming to ANSI A156.16, for flush bolts required on lower part of doors. Modify flush bolts to fit stiles of aluminum doors on double-acting doors.

B. Face plates for cylindrical strikes to be rectangular and not less than

25 mm by 63 mm (1 inch by 2-1/2 inches).

C. Friction-fit cylindrical dustproof strikes with circular face plate may be used only where metal thresholds occur.

2.14 DOOR PULLS WITH PLATES

A. Conform to ANSI A156.6. Pull plate 90 mm by 350 mm (3-1/2 inches by 14 inches), unless otherwise specified. Cut plates of door pulls for cylinders, or turn pieces where required.

2.15 PUSH PLATES

A. Conform to ANSI A156.6. Metal, Type J302, 200 mm (8 inches) wide by 350 mm (14 inches) high. Provide plastic Type J302 plates 100 mm (4 inches wide by 350 mm (14 inches) high) where push plates are specified for doors with stiles less than 200 mm (8 inches) wide. Cut plates for cylinders, and turn pieces where required.

2.16 COMBINATION PUSH AND PULL PLATES

A. Conform to ANSI 156.6, Type J303; stainless steel 3 mm (1/8 inch) thick, 80 mm (3-1/3 inches) wide by 800 mm (16 inches) high), rounded top and bottom edges. Secure plates to wood doors with 38 mm (1-1/2

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 9 inch) long No. 12 wood screws. Cut plates for turn pieces, and cylinders where required. Mount pull in down direction.

2.17 THRESHOLDS

A. Conform to ANSI A156.21, mill finish extruded aluminum, except as otherwise specified. In existing construction, install thresholds in a bed of sealant with machine screws and expansion shields. In new construction, embed aluminum anchors coated with epoxy in concrete to secure thresholds. Furnish thresholds for the full width of the openings.

B. At exterior doors and any interior doors exposed to moisture, provide threshold with non-slip abrasive finish.

2.18 WEATHERSTRIPS (FOR EXTERIOR DOORS)

A. Conform to ANSI A156.22. Air leakage must not to exceed 0.50 CFM per foot of crack length (0.000774m3/s/m).

2.19 PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHES

A. ASTM F883, size 50 mm (2 inch) wide chain; furnish extended shackles as required by job conditions. Provide padlocks, with key cylinders, for each door in following areas as noted.

B. Key padlocks as follows:

1. Chain Link Fence Gates.

2. Roof Access and Scuttles: Engineer's set.

2.20 FINISHES

A. Exposed surfaces of hardware to have ANSI A156.18 finishes as specified below. Provide finishes on all hinges, pivots, closers, thresholds, etc. as specified below under "Miscellaneous Finishes." For field painting (final coat) of ferrous hardware, see Section 09 91 00, PAINTING.

B. 626 or 630: Surfaces on exterior and interior of buildings, except where other finishes are specified.

C. Miscellaneous Finishes:

1. Hinges - Exterior Doors: 626 Bronze color.

2. Hinges - Interior Doors: 652.

3. Door Closers: Factory applied paint finish. Dull or Satin Aluminum color Dull Brass color.

4. Thresholds: Mill finish aluminum.

5. Other primed steel hardware: 652.

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 10

2.21 BASE METALS

A. Apply specified U.S. Standard finishes on different base metals as following:

Finish Base Metal

652 Steel

626 Brass or bronze

630 Stainless steel

PART 3 - EXECUTION

3.1 HARDWARE HEIGHTS

A. Locate hardware on doors at heights specified below unless otherwise noted:

B. Hardware Heights from Finished Floor:

1. Exit devices centerline of strike (where applicable): 1000 mm

(40-5/16 inches).

2. Locksets and latch sets centerline of strike: 1000 mm (40-5/16 inches).

3. Deadlocks centerline of strike: 1200 mm (48 inches).

4. Centerline of door pulls: 1000 mm (40 inches).

5. Push plates and push-pull: 1250 mm (50 inches) to top of plate.

6. Push-pull latch: 1000 mm (40-5/16 inches) to centerline of strike.

7. Centerline of deadlock strike: 840 mm (33 inches) when used with push-pull latch.

8. Locate other hardware at standard commercial heights.

9. Locate push and pull plates to prevent conflict with other hardware.

3.2 INSTALLATION

A. Equip and mount closer devices, including those with hold-open features, to provide maximum door opening permitted by building construction or equipment. Closers to be mounted regular arm. Where closers are mounted on doors, mount with sex nuts and bolts; foot fastened to frame with machine screws.

B. Substitute parallel arm or top jamb mounting for regular arm mounting where the following conditions occur:

1. Where door swing, in full open position, would be limited to less than 90 degrees due to partition construction and closer location.

2. Where door to room opens outward into corridor.

3. Where exterior doors open outward.

C. Hinge Size Requirements:

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 11

Door Thickness Door Width Hinge Height

45 mm (1-3/4 inch) 900 mm (3 feet) and less 113 mm (4-1/2 inches)

45 mm (1-3/4 inch) Over 900 mm (3 feet) but not more than 1200 mm (4 feet)

125 mm (5 inches)

35 mm (1-3/8 inch)

(hollow core wood doors)

Not over 1200 mm (4 feet) 113 mm (4-1/2 inches)

D. Provide hinge leaves sufficiently wide to allow doors to swing clear of door frame trim.

F. Hinges Required Per Door:

Doors 1500 mm (5 ft) or less in height 2 butts

Doors over 1500 mm (5 ft) high and not over 2280 mm

(7 ft 6 in) high

3 butts

Doors over 2280 mm (7 feet 6 inches) high 4 butts

Dutch type doors 4 butts

Doors with spring hinges 1370 mm (4 feet 6 inches) high or less

2 butts

Doors with spring hinges over 1370 mm (4 feet 6 inches) 3 butts

G. Fastenings: Suitable size and type to suit with hardware as to material and finish. Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry.

Fiber or rawl plugs and adhesives are not permitted. All fastenings exposed to weather must be of nonferrous metal.

H. After locks have been installed; show in presence of COR that keys operate their respective locks in accordance with keying requirements.

(Send keys, Master Key level and above by Registered Mail to the

Cemetery Director along with the bitting list. Also send a copy of the invoice to the COR for the records.) Installation of locks which do not meet specified keying requirements will be considered sufficient justification for rejection and replacement of all locks installed on project.

3.3 FINAL INSPECTION

A. Installer to provide letter to COR that upon completion, installer has visited the Project and has accomplished the following:

1. Re-adjust hardware.

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 12

2. Evaluate maintenance procedures and recommend changes or additions, and instruct VA personnel.

3. Identify items that have deteriorated or failed.

4. Submit written report identifying problems.

3.4 HARDWARE SETS

A. Following sets of hardware correspond to hardware symbols shown on drawings. Where hardware set for a single door is specified for a pair of doors; equip each leaf of such pair of doors with set noted. Only those hardware sets that are shown on drawings will be required.

Disregard hardware sets listed in specifications but not shown on drawings.

1. MK - McKinney

2. PE - Pemko

3. RO - Rockwood

4. YA - ASSA ABLOY ACCENTRA

5. BE - BEST Locks & Closers

6. HS - HES

7. RF - Rixson

8. NO - Norton

9. SU - Securitron

Set: HW-1

Doors: 3002-114B

3 Hinge (A8112) TA2714 US26D MK

1 Passage Set (F01) AUR 8801FL 626 YA

Surface Closer (C02011 /

C02021)

R 8501 / PR 8501 689 NO

1 Kick Plate (J102) K1050 10" BEV CSK US32D RO

1 Wall Stop (L02101) 401 US26D RO

1 Adhesive Gasketing (R0Y154) S88BL PE

Set: HW-1.1

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 13

Doors: 3002-105A

Set: HW-1.2

Doors: 3002-101B, 3002-104A, 3002-106A

1 Overhead Stop (C01541) 1ADJ-X36 652 RF

Surface Closer (C02011 /

C02021)

R 8501 / PR 8501 689 NO

1 Kick Plate (J102) K1050 10" BEV CSK US32D RO

Set: HW-1.3

Doors: 3002-101A

1 Continuous Hinge (A31031G) _FM (height) HD1 PE

1 Push Bar & Pull (J505) BF15847 US10BE RO

Surface Closer (C02011 /

C02021)

R 8501 / PR 8501 690 NO

1 Kick Plate (J102) K1050 10" BEV CSK US10B RO

1 Sweep (R0Y416) 18061_NB PE

Set: HW-3 - Not Used

Set: HW-6

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 14

Doors: 3003-100C

3 Hinge (A2111) T4A3386 US26D MK

1 Rim Exit (Type 1, 14) 6100ED AU628F 630 YA

1 Overhead Stop (C01541) 1ADJ-X36 652 RF

Surface Closer (C02011 /

C02021)

R 8501 / PR 8501 689 NO

1 Kick Plate (J102) K1050 10" BEV CSK US32D RO

Set: HW-6.1 - Not used

Set: HW-7

Doors: 3002-112A, 3002-113A, 3002-114A, 3003-100B, 3003-101A, 3003-101B, 3003-101C, 3003-102A, 3003-102B, 3003-102C, 3003-103A, 3003-103B, 3003-103C, 3004-100A, 3004-100C

1 Cylinder TYPE AS REQUIRED 626

1 I.C. Core As Specified BE

Notes: Balance of hardware by door supplier.

Set: HW-11

Doors: 3002-107A

6 Hinge (A8112) TA2714 US26D MK

1 Flush Bolt (Type 25) 2848 / 2948 US32D RO

1 Storeroom Lock (F07) AUR 8805FL Temp Core 626 YA

1 I.C. Core As Specified BE

1 Coordinator (Type 21A) 2600 Series Black RO

2 Overhead Stop (C01541) 1ADJ-X36 652 RF

Surface Closer (C02011 /

C02021)

R 8501 M / PR 8501 M 626 NO

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 15

2 Kick Plate (J102) K1050 10" BEV CSK US32D RO

2 Floor Stop (L02121) 470 US26D RO

1 Astragal (R0Y634) 357C PE

2 Adhesive Gasketing (R0Y154) S88BL PE

Set: HW-SH1

Doors: 3002-102A, 3002-111A

1 Storeroom Lock (F07) AUR 8805FL Temp Core 626 YA

1 I.C. Core As Specified BE

1 Electric Strike (E09391) 1600-CDB 630 HS

1 SMART Pac Bridge Rectifier 2005M3 HS

Surface Closer (C02011 /

C02021)

R 8501 M / PR 8501 M 626 NO

1 Kick Plate (J102) K1050 10" BEV CSK US32D RO

1 Wall Stop (L02101) 401 US26D RO

1 Adhesive Gasketing (R0Y154) S88BL PE

1 Frame Harness QC-C1500P MK

1 Door Harness QC-C___ MK

1 Position Switch (E08) DPS-M-BK SU

1 Card Reader BY SECURITY INTEGRATOR

1 Power Supply AQ_ (Amperage & relays as req'd)

SU

Notes:

Coordinate reader location with contractor.

Coordinate power with electrical contractor.

• Doors normally closed and secure.

• Authorized access by valid read at reader releases electric strike for entry via lever

• Egress free for immediate exit at all times

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 16

• Door remains locked (fail secure) in event of power loss.

• Keyed cylinder override for emergency access.

Set: HW-SH2

Doors: 3002-100A, 3002-103A, 3003-100A, 3003-103D

Continuous Hinge (ELEC)

(A31031G) _FM (Height) HD1 SER12 PE

1 Exit Device (Type 8, E03) 6100ED B MELR 121NL 613E YA

Interchangeable Core

(E09241)

33600006N 26 MC

1 Rim Cylinder (E09261) K680 626 YA

1 Door Pull (J402) BF158 US32D RO

1 Overhead Stop (C01541) 1ADJ-X36 652 RF

Surface Closer (C02011 /

C02021)

R 8501 M / PR 8501 M 626 NO

1 Kick Plate (J102) K1050 10" BEV CSK US32D RO

1 Head Gasketing (R0Y164) 2893AV PE

1 Jamb Gasketing (R0Y164) 2903AV PE

1 Rain Guard (R0Y976) 346C PE

1 Sweep (R3A434) 293100CNB PE

1 Threshold (outswing door) 273x224AFGT PE

1 Frame Harness QC-C1500P MK

1 Door Harness QC-C___ MK

1 Position Switch (E08) DPS-M-BK SU

1 Card Reader BY SECURITY INTEGRATOR

1 Power Supply AQ_ (Amperage & relays as req'd)

SU

Notes:

Coordinate reader location with contractor.

Coordinate power with electrical contractor.

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 17

• Doors normally closed and secure.

• Authorized access by valid read at reader will retract latch and allow entry via pull

• Egress free for immediate exit at all times

• Door remains locked (fail secure) in event of power loss.

• Keyed cylinder override for emergency access.

Set: HW-SH2.1

Doors: 3004-100B

3 Hinge (A2111) T4A3386 US26D MK

1 Rim Exit Device, Exit Only 6100ED EO 630 YA

Surface Closer (C02011 /

C02021)

UNI8501 689 NO

1 Head Gasketing (R0Y164) 2893_V PE

1 Jamb Gasketing (R0Y164) 2903_V PE

1 Sweep (R0Y416) 18061_NB PE

1 Threshold (outswing door) 273x224_FGT PE

1 Rain Guard (R0Y976) 346_ PE

Set: HW-SH3

Doors: 3002-108A, 3002-109A, 3002-110A

1 NexTouch keypad w DB, keyed NTM613 626 YA

1 I.C. Core As Specified BE

Notes: Battery operated keypad on door.

• Doors normally closed and secure.

• Authorized access by valid read at keypad

Leavenworth, KS 66048

DOOR HARDWARE

08 71 00 - 18

• Egress free for immediate exit at all times

• Door remains locked (fail secure) in event of power loss with key override for entry.