36C78619B0002-0003012.pdf

PDF 141 KB Posted

Attached to
Renovations at the BNC Administration Building at Baltimore National Cemetery.
Solicitation number
36C78619B0002
Issued by

About this file

36C78619B0002 0003 7. LCN_8310-866_Bollard_Mounting_Post_User_Guide_109473.pdf

View the file

Other files

File Type Posted
36C78619B0002-0004000.docx DOCX document
36C78619B0002-0003011.pdf PDF
36C78619B0002-0003003.pdf PDF
36C78619B0002-0003005.pdf PDF
36C78619B0002-0003006.pdf PDF
36C78619B0002-0003004.pdf PDF
36C78619B0002-0003009.pdf PDF
36C78619B0002-0003001.pdf PDF
36C78619B0002-0003007.pdf PDF
36C78619B0002-0003000.docx DOCX document
36C78619B0002-0003008.pdf PDF
36C78619B0002-0003002.pdf PDF
36C78619B0002-0003013.pdf PDF
36C78619B0002-0003010.pdf PDF
36C78619B0002-0002000.docx DOCX document
802-NRM19-05_Treatment_Plan.pdf PDF
36C78619B0002_0001.docx DOCX document
802-NRM19-05_Full_Specifications_red_12-28-18.pdf PDF
802-NRM19-05_Hazardous_Materials_Investigation.pdf PDF
802-NRM-19-05_SOW_Summary_-_12-28-18.pdf PDF
36C78619B0002.docx DOCX document
802-NRM19-05_Full_Drawings.pdf PDF
36C78619B0002_Presol.docx DOCX document
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2 Specifi cations

MOUNTING POST FOR PUSH PLATES

1 Description

The Bollard (8310-866) is used for mounting pushplates that activate automatic doors. It will accept LCN’s 4 3/4” Square Pushplate and 4 3/4” Square Wireless Pushplate. The post is made of durable carbon steel and the mounting bracket is made of stainless steel for strength. It can be mounted on either existing concrete or newly poured concrete.

DESCRIPTION SPECIFICATION

Dimensions (with cap attached) 41 ½”H x 6 ¼” W x 4 ¼”D

Material

• Post

• Cap

• Mounting Bracket

Powder-Coated (Inside and Out) Carbon Steel UV-Resistant ABS Plastic Stainless Steel

Pushplate Options 4 3/4” Square and 4 3/4” Square Wireless Pushplates

Weight 35 lbs (16 kilos)

Color Aluminum or Dark Bronze

Mounting Hardware L-Anchors, Expansion Anchors, Split Washers and Nuts (Included)

PLASTIC CAP (8310-866CAP)

TRANSMITTER MOUNTING TRAY (HIDDEN)

NOT USED WITH PANTHER APPLICATION

PUSH PLATE MOUNTING BOX (HIDDEN)

PUSH PLATE (NOT INCLUDED) WILL ACCEPT:

4 3/4” SQUARE PUSHPLATE

4 3/4” SQUARE WIRELESS PUSHPLATE

POST ASSEMBLY

POST MOUNTING BRACKET (HIDDEN)

POST MOUNTING SCREWS (4)

CAP MOUNTING SCREWS (3)

75.5305.01 20080314 Page 1 of 4

USER’S GUIDE

8310-866 BOLLARD MOUNTING POST

2 Attach Mounting Bracket Using Expansion Anchors - Existing Concrete

1. Mark and drill 3/8” diameter hole in four locations.

2. Hammer in and set anchor in four hole locations.

3. Install and tighten nuts to secure mounting bracket.

3 Precautions

Shut off all power going to header before attempting any wiring procedures.

Maintain a clean & safe environment when working in public areas.

Constantly be aware of pedestrian traffi c around the door area.

Always stop pedestrian traffi c through the doorway when performing tests that may result in unexpected reactions by the door.

Always check placement of all wiring before powering up to insure moving door parts will not catch any wires and cause damage to equipment.

Ensure compliance with all applicable safety standards (example: ANSI A156.19 / A156.10) upon completion of installation.

DO NOT attempt any internal repair of the sensor. All repairs and/or component replacements must be performed by LCN.

Unauthorized disassembly or repair:

1. May jeopardize personal safety and may expose one to the risk of electrical shock.

2. May adversely affect the safe and reliable performance of the product will result in a voided product warranty.

4 Pre Installation Check

1. When preparing to wire multiple devices together for a ‘system’ confi guration, it is best to ensure the correct operation of each device inde-pendently before starting to help reduce troubleshooting time later in the event of a discrepancy.

2. Prior to installing any equipment, ensure correct line voltage and stability. When applying equipment on a new installation utilizing new electrical supply circuits, always ensure correct line voltage exists and is stable. Remember to shut the power back off after this is checked and before performing any wiring to the system.

5 Installation

1 Hardwire Bracket - Optional

1. The Bollard is designed to house a pushplate used to activate a door by either a remote controlled transmitter or hardwired directly to the door control. If the door is hardwired, pass the wire through the 1 inch diameter hole in the mounting bracket.

FOR HARDWIRING, RUN WIRE

THROUGH 1” DIAMETER HOLE

Page 2 of 4 75.5305.01 20080314

2.19 in

55.58 mm

1/4-20

53.95 mm

2.12 in

3.65 in

25.40 mm

143.51 mm

5.65 in

0.44 in

11.11 mm

92.71 mm

1.00 in

39.37 mm

1.55 in

5 Installation (Continued)

3 Attach Mounting Bracket Using ‘L’ Shaped Anchors - New Concrete

1. Pour concrete at least 6 inches deep. 2. Insert anchors into curing concrete. Leave at least 1 inch exposed.

3. Once concrete has cured attach anchor and tighten nuts onto mounting bracket.

4 Attach Post to Mounting Bracket

1. Align post to mounting bracket and attach post to mounting bracket with four post mounting screws.

5 Install Push plate

1. Thread the push plate screws into the mounting box leaving a majority of the screw exposed. Attach the pushplate to the mounting screws, then use the hex key provided to fully tighten the screws. Refer to the appropriate pushplate User’s Guide for detailed installation and setup instructions.

PUSHPLATE INSTALLATION DUAL VESTIBULE INSTALLATION PANTHER PUSHPLATE INSTALLATION

75.5305.01 20080314 Page 3 of 4

6”

1” EXPOSED

5 Installation (Continued)

6 Attach Transmitter

CAUTION: IF THE TRANSMITTER IS ALLOWED TO HANG DOWN INSIDE THE BOLLARD, ERRATIC OPERATION MAY OCCUR.

1. If using the transmitter for this application, attach transmitter to mounting tray with velcro pad included in the package. Hardwired systems do not require this step.

2. Attach plastic cap to top of the post with three cap mounting screws. Tighten screws with hex key included in the pushplate package.

TRANSMITTER MOUNTING TRAY

ATTACH

TRANSMITTER

HERE

6 Company Contact

Page 4 of 4 75.5305.01 20080314

Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please contact LCN at 1-800-526-2400. If you must wait for the following workday to call LCN, leave the door inoperable until satisfactory repairs can be made. Never sacrifi ce the safe operation of the automatic door or gate for an incomplete solution.

For more information, visit www.lcn.ingersollrand.com.