VISN 2 Industry Day Presentation - Final REV - 11-19-26 R1.pptx
PPTX presentation 12 MB Posted
- Attached to
- Y1DA--VISN 2 EHRM Industry Day
- Solicitation number
- 36C77627Q0002
About this file
This file is a PowerPoint presentation from the VISN 2 Electronic Health Records Modernization (EHRM) Industry Day held on November 19, 2026, at the James J. Peters VA Medical Center in Bronx, New York. The presentation outlines seven major EHRM infrastructure upgrade projects across VISN 2 (New York/New Jersey) facilities: Bronx, Canandaigua, Manhattan, Northport, St. Albans, Buffalo, and East Orange. Five projects are anticipated for FY27 solicitation and award (Bronx, Canandaigua, Manhattan, Northport, and St. Albans), while Buffalo and East Orange will be solicited in FY27 but awarded in early FY28. The primary scope across all sites includes upgrading fiber optic networks and power distribution to comply with EHRM design standards, with work encompassing telecommunications room renovations or relocations, installation of new data centers with redundant pathways, Category 6A cabling upgrades, electrical distribution improvements, HVAC systems, physical security enhancements, and hazardous material abatement.
Each project presents unique site-specific challenges requiring phased construction to maintain operations at active healthcare facilities. Key procurement considerations include determining whether to use Invitation for Bid (IFB), Lowest Price Technically Acceptable (LPTA), or Trade-Off evaluation methods, with the VA noting that FY26 projects received limited interest from Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) and considering broader competition strategies for FY27. The presentation covers post-award administration requirements, including use of Autodesk Build for all project documentation, Davis-Bacon Act wage compliance with certified weekly payrolls, infection control risk assessments (ICRA), coordinated utility shutdowns, and security badging procedures. Performance periods are anticipated at two to three years, with potential Project Labor Agreements (PLAs) required for projects near or exceeding $35 million. The VA emphasized the need for prebid site visits, detailed phasing plans, coordination with infection control and IT departments, and understanding of dense urban access constraints and existing building conditions at each location.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C77627Q0002_0002.docx | DOCX document | |
| VISN 2 Industry Day Sign In Sheet.pdf | ||
| VISN 2 St Albans -Queens- Data Center - Civil SIte Plan.pdf | ||
| VISN 2 Bronx - Civil SIte Plan.pdf | ||
| VISN 2 Canandaigua - Civil SIte Plan.pdf | ||
| VISN 2 East Orange - Civil SIte Plan.pdf | ||
| VISN 2 Industry Day - Site Instructions Bronx JA.docx | DOCX document | |
| 36C77627Q0002_0001.docx | DOCX document | |
| VISN 2 Northport Data Center - Civil SIte Plan.pdf | ||
| VISN 2 Buffalo - Civil SIte Plan.pdf | ||
| VISN 2 Manhattan - Floor Plan.pdf | ||
| 36C77627Q0002.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VISN 2 EHRM
Industry Day November 19, 2026
August 30, 2017
VA
Key Leaders Meeting
Donny Marsh, Division Chief Joe Rossano, Pre Award CO Sam Cornwell, Pre Award CS Chris Yong, Post Award CO Freddy Flores, Post Award CS
Introductions - OFA PCAC Team
Special Engineering Projects (SEP) National Office:
Jim Cullum, Capital Support Engineer, FRO-SEP Jo Jo Todd, Deployment Manager Prab Mathone, Construction Manager Mike Neese, Integration Engineer, CM Support
Introductions – Facilities Requirements & Oversight Team (FRO)
Bronx VAMC: Amir Elgabari, Mike Pilsbury Northport VAMC: Mike Kulak, John Yousseff, Khalid Nagidi & Brian Eichhorn East Orange VAMC: Lukasz Romaniecki and Mike Kaleda Manhattan VAMC: Danielle Fix St. Albans: John Situ
Introductions - VISN 2 Site Engineers
Goals of Industry Day Present the VA’s objectives and requirements for the upcoming VISN 2 EHRM Infrastructure projects, engage industry partners of all sizes, and gather market insight needed to determine the most effective procurement and set-aside strategy for these complex efforts.
Legacy VISN 2 (New York/New Jersey) has five EHRM projects that are anticipated to be solicited and awarded in FY 2027 and four in FY 2028.
The five planned projects for FY27 are at the Bronx, Canandaigua, Manhattan, Northport, and St. Albans. The Buffalo and East Orange projects will be started in FY27 but awarded in early FY28.
FY27 EHRM Projects
EHRM Program Overview FY27 EHRM Projects Site Walk – Bronx Procurement Discussion Post Award Administration Q&A Closing Remarks Networking *We will try to wrap up around 3 PM Today’s Agenda
Jim Cullum, Capital Support Engineer
Facilities Requirements and Oversight – Special Engineering Projects (FRO-SEP) is the program office responsible for the entire lifecycle administration of EHRM infrastructure upgrades Collaborates with internal experts and VA stakeholders to optimize constructability and consistency in standards application Drive cost-efficient project outcomes
EHRM Program Overview Ensure schedule compliance and optimization Risk/Issue management What SEP does:
Roles and Responsibilities Special Engineering Projects (SEP) National Office:
Jim Cullum, Capital Support Engineer, FRO-SEP Jo Jo Todd, Deployment Manager Prab Mathone, Construction Manager Mike Neese, Integration Engineer, CM Support Binisha Shrestha, Integration Engineer
EHRM Site Overview
General Narrative Summary
OVERALL GOALS & MAJOR DESIGN ELEMENTS
This campus-wide project focuses on upgrading the VAMC’s fiber network and power distribution in compliance with EHRM design guides.
Major Design Elements:
Fiber network upgrades with redundant routes to IT closets and the demarcation room Telecommunications room expansions or relocations and installation of 100 IT outlets and 75 electrical outlets Power distribution and HVAC upgrades Physical security improvements and hazardous material abatement
Canandaigua VAMC
Project Scope Key Strategies / Project Scope:
Risk Management: Utilization of a risk register to proactively identify and mitigate potential challenges.
Infrastructure optimization: Expansion or relocation of existing Telecommunication Rooms, with minimal impact on the facility's ongoing operations and staff.
Security Integration: Ensuring high-level security for data cabinets, fiber infrastructure, and telecommunication rooms, including the installation of lockable manhole covers for underground fiber pathways.
Phased Implementation: Development of a detailed phasing plan, including dust control and infection control risk assessments, to minimize disruptions to the facility during construction.
Key Challenges, Unique Aspects, or Site-Specific Conditions Early contractor considerations
Canandaigua VAMC Coordinate phased construction to minimize disruptions to daily campus operations Expansion or relocation of existing Telecommunication Rooms, with minimal impact on the facility’s ongoing operations and staff Detailed phasing plan, including dust control and infection control risk assessments, to minimize disruptions during construction Hazardous material abatement
Key Challenges, Unique Aspects, or Site-Specific Conditions Key project details
Site Layout – Canandaigua VAMC
Project Summary and Scope
Upgrades electrical and telecommunication infrastructure at the Buffalo VAMC to support the EHRM program without disrupting ongoing operations.
Replaces fiber, telecom cable trays, conduits, cabling, and performs HVAC/electrical upgrades in new and renovated Telecommunications Rooms.
Provides full recabling across multiple campus buildings, including new TRs, redundant site infrastructure, and improvements to the main computer room (new CRAC units, racks, and fiber landing).
Delivers comprehensive modernization of communications systems: new fiber and CAT6a cabling, work area outlets, racks, UPS units, power distribution, HVAC, CCTV, fire protection and alarm, utility monitoring, PACS, and door systems.
Buffalo VAMC
Key Challenges, Site Conditions, and Distinguishing Features Extensive phasing and critical path scheduling required to maintain network uptime and ensure no more than two buildings are disrupted at once.
Third‑party inspections and building-specific commissioning must be integrated into the construction schedule.
LIDAR scans provided to bidders for accurate pre‑bid review; monthly LIDAR surveys support progress documentation and digital twin development.
Contract documents include detailed requirements for phasing, ILSM, hazmat handling, and commissioning.
Buffalo VAMC
Site Layout - Buffalo VAMC
Project Overview Modernizes telecommunications and IT infrastructure across Buildings 1, 2, 3, and 6 at the Margaret Cochran Corbin VA Campus.
Relocates and builds a new campus data center with redundant fiber pathways, dedicated cooling, and 2N UPS/electrical redundancy.
Renovates 53 telecommunications rooms and enclosures and upgrades pathways, cabling, and fiber distribution.
Major scope includes:
Data center build-out with fire protection, physical security, and year‑round cooling Category 6A cabling, redundant WAN/fiber pathways, telecom room upgrades Standalone chilled‑water system and ductless fan‑coil units for TR cooling Electrical distribution improvements supporting telecom and mechanical loads Architectural renovations, rooftop equipment protection, hazmat abatement, and civil coordination with existing flood barriers
Manhattan VAMC
Key Challenges & Unique Aspects
Dense urban campus with limited access for material staging, deliveries, hoisting, worker parking, and equipment logistics.
Relocated data center requires carefully sequenced construction, commissioning, migration, and cutover to maintain uninterrupted operations.
Renovation of 53 TRs demands phased access in occupied clinical buildings with close coordination with VA IT and clinical departments.
Dedicated chilled‑water system must operate independently of the main campus system; rooftop equipment requires structural and environmental planning.
Flood barriers and site constraints affect civil routing and exterior access.
Early identification needed for dependencies with third‑party vendors, concurrent station projects, and incomplete record drawings.
Manhattan VAMC
Site Layout – Manhattan VAMC
General Project Summary
Upgrade the Northport VAMC network cable plant to Category 6A structured cabling and a robust fiber‑optic backbone to meet EHRM reliability and bandwidth requirements.
Construct a new standalone data center building, including generator capacity to power the data center and restore emergency power to Building 12. Existing generator to be removed after installation of the new generator.
Project scope includes:
New Telecommunications Rooms (TRs) throughout the facility New fiber backbone, Cat6A cabling, TR adjustments (keep/relocate/remove) across multiple buildings.
New data center with associated physical security upgrades.
Electrical infrastructure corrections and hazardous materials abatement.Detailed LAN and data center phasing to minimize downtime.
Northport VAMC
Key Challenges, Site Conditions, and Distinguishing Features
Highly congested building connectors complicate routing of new fiber, power, and infrastructure—critical for bidders to review existing pathways.
Strongly recommended pre‑bid site visit to assess congested pathways, TR locations, obsolete electrical panels (e.g., Federal Pacific), and field constraints; electrical one‑lines must match verified arc‑flash study conditions.
Unique campus layout: interconnected buildings via partially underground connectors, creating complex routing, phasing, and congestion challenges.
Six outbuildings require new underground duct banks for fiber connectivity to the new data center/backbone.
Distinguishing features include:
Standalone data center with coordinated emergency power restoration for Building 12 Extensive multi‑building TR right‑sizing and selective scope reductions due to occupancy changes and concurrent projects (ICU, ED, Boiler Plant).
Rigorous multi‑phase LAN/data center migration plan with temporary fiber routes, dual fiber runs, 90‑day relocation windows, and close coordination with OIT and BioMed to maintain continuous operations.
Northport VAMC
Site Layout – Northport VAMC
General Project Summary
Provides full Architect‑Engineer design services to upgrade campus‑wide infrastructure at St. Albans VAMC in support of the EHRM system.
Overall goals include:
Upgrading network cable plant to Category 6A and a modernized fiber‑optic backbone, including new outlets and patch panels Designing a new small data center attached to Building 89 with full MEP, power, UPS, HVAC, finishes, and cable management Designing a new Telecommunications Room (TR) tower at Building 89 to support critical network infrastructure High‑level project scope:
Electrical upgrades (panels, normal/emergency power, bonding, UPS, BMS interfaces) HVAC assessment and system upgrades Reconfiguration and renovation of existing spaces (demolition, new construction, finishes, cabling) Construction of a new TR tower and new data center with all supporting infrastructure Campus‑wide communications improvements (Cat6A, patch panels, new outlets) Physical security enhancements and hazardous materials abatement Backbone fiber upgrades within and between buildings, including diversified WAN pathways Scope spans Buildings 88, 89, 86, 85, 87, 92, 173, 60, 64, 91, 93, plus site work St. Albans VAMC
Key Challenges, Site Conditions & Distinguishing Features
Building 89 contains lathe‑and‑plaster ceilings above existing suspended ceilings, complicating routing for new infrastructure and requiring careful field coordination.
Thorough pre‑bid site visits are strongly recommended to assess above‑ceiling conditions, access limitations, and existing infrastructure constraints.
Multi‑story connector corridors between buildings create unique campus‑wide routing, phasing, and coordination challenges for cable pathways and utilities.T Two outbuildings require underground construction; an additional building (energy plant) connects via underground steam tunnel, impacting pathway design and construction sequencing.
St. Albans VAMC
Site Layout – St. Albans VAMC
General Summary
EHRM initiative supports national VA efforts to strengthen cybersecurity and modernize telecommunications infrastructure.
Project scope at East Orange includes:
Renovation and modernization of the Data Center in Building 1 Installation of a campus‑wide, fully redundant fiber‑optic backbone Renovation and modernization of Telecommunications Rooms across all campus buildings Upgrading all buildings to Category 6A cabling East Orange VAMC
Key Challenges & Site‑Specific Conditions
Construction of a 15‑story Telecommunications Room tower to create ~170 SF of new TR space per floor due to limited existing capacity in Building 1. Access to create footing in C-level maybe difficult. Crane staging maybe a challenge SHPO‑driven design requirements to match the historic exterior façade of Building 1 Phased renovation of the existing Data Center to maintain continuous network operations Use of existing utility tunnels for backbone installation to minimize parking disruption and avoid extensive trenching or new duct bank work. All trenching will be mainly for Buildings 2,15-18 and 11.
Building 1 work will require awareness of Infection Control and proper phasing when running/ replacing cables with emphasis to most critical areas for example Inpatient floors, Mental Health, SCI, O.R., SPS, ED, Dialysis.
East Orange VAMC
Site Layout – East Orange VAMC
Bronx VAMC
PROJECT OVERVIEW
Modernizes the campus technology backbone and supports EHRM implementation at the James J. Peters VAMC.
Includes construction of two new telecommunications towers requiring coordinated structural, civil, architectural, MEP, and telecom design.
Includes repurposing an abandoned dumbwaiter shaft as a new tower by removing existing equipment, adding floors and providing access through housekeeping rooms.
Renovates and expands existing data center and new TR spaces; upgrades power, cooling, fiber, security, and life‑safety systems.
Campus-wide improvements include:
– New Category 6A cabling and fiber backbone
– Data center power, cooling, and cable‑management enhancements
– Electrical system installations (normal/emergency power, UPS, panels, bonding)
– New HVAC for the towers and other spaces, and BMS integration
– Architectural renovation, fire protection, physical security, and hazmat abatement
Bronx VAMC
KEY CHALLENGES & UNIQUE ASPECTS
• Three new telecom towers are a major project differentiator requiring precise alignment with existing hospital elevations.
• Tower connections at the basement level require detailed access and interface coordination.
• Existing smokestack demolition by another contractor must occur before tower construction can begin.
• Active healthcare environment requires early planning for access controls, outages, telecom cutovers, and infection‑control requirements.
• Existing conditions and hazmat may influence sequencing; extensive field verification recommended.
• Limited TR space requires close coordination with VA stakeholders and concurrent projects.
Site Layout – Bronx VAMC
Site Walk Stay together as a group Please refrain from asking questions, submit in writing Changes to the solicitation can only be implemented via amendments After site walk, we will break for lunch Are there any Bronx specific parts to add?
PLEASE COME BACK WITHIN 1 HOUR
SPECIFIED TIME WILL BE GIVEN AFTER WALK
LUNCH
Procurement Discussion Joseph Rossano and Samuel Cornwell
Market Research and Set-Aside Determination Procurement Method – IFB vs RFP (LPTA or Tradeoffs) FY26 Procurement Examples / Factors Period of Performance Project Labor Agreement (PLA)
General Discussion Points
Sources Sought Notice - typically issue a sources sought notice on SAM.gov. It’s important you look out for this and respond with your interest and capabilities related to EHRM projects.
Small Business SBA.gov Search Email – we generate a list of verified SDVOSBs and/or Small Businesses with specific criteria (NAICS, bonding level etc.).
Lack of responses from capable contractors, may result in a non-SDVOSB set-aside or an unrestricted procurement.
This Industry Day is to promote further interest and competition FY26 had limited interest in some sites Market Research and Set-Aside Determination
Invitation For Bid (IFB) Sealed Bidding Process – Publicly solicited, competitive bids, no discussions or negotiations Award based on lowest price; responsibility determination will be conducted on the apparent low bidder Clear and defined requirements as per the specifications; no technical factors Most streamlined of the procurement methods and typically quicker timeframe Bid opening; offerors must follow the IFB or risk being determined nonresponsive
Procurement Method
Lowest Price Technically Acceptable (LPTA) Award based on the lowest priced technically acceptable offer Technical factors can help ensure offerors better understand the project requirements The proposals must meet the minimum acceptability standards for the established technical factors A competitive range may be established in order to conduct negotiations
Trade-Off Evaluates price and non price factors Allows consideration of technical approach, experience, past performance, etc.
Tradeoffs may be applied when justified, to award to a higher rated offeror at a higher price Overall objective remains to select the proposal that provides the best value to the government based on the solicitation's evaluation criteria, regardless of the use of Tradeoffs or LPTA
IFB (Price only) Bath, Syracuse, Brooklyn, Castle Point
RFP LPTA Lyons – Qualifications, Key Subcontractors, Price (minimum acceptability for non price related factors)
RFP TRADEOFF - Montrose - Past Performance
FY26 Procurement Examples / Factors
Anticipated Period of Performance for these EHRM projects is between 2 and 3 years Communicate to us if these timeframes are too short What issues unique to New York may increase the performance period?
Period of Performance
Required for construction projects over $35M by Executive Order 14063 and RFO 22.502-1(b) Exemption memo is required if we do not include one For projects near or over $35M, the Sources Sought Notices includes a PLA Questionnaire Size, complexity, labor availability, impact on competition Providing thorough responses to the PLA questions help us make a clear determination on whether to include or not Goal remains to promote competition
Project Labor Agreement (PLA)
Post Award Administration Chris Yong, Post Award Contracting Officer
Transition into post-award administration. Explain that the rest of the session covers how the government and contractors work together after award.
Who's Who After Award
Contracting Officer (CO) Changes the contract, approves payments, and handles disputes.
COR
Oversees daily work on site. Cannot change the contract.
Project Manager and Contract Specialist Handle day-to-day coordination and contract paperwork.
Walk through the three roles and when to call each one. Share the org chart with names and phone numbers on the handout, and remind contractors to confirm names at the kickoff meeting.
Only the CO Changes the Contract Only a written modification signed by the CO changes the contract.
Verbal direction from site staff is not a contract change.
If something sounds like new work, ask the CO to confirm it in writing before you start.
Key message: verbal direction from site staff is not a contract change. If you receive a request that sounds like new work, ask the CO to confirm it in writing before you start. Share one real example of a verbal request that became a dispute, without naming anyone.
Notice to Proceed and Kickoff
Notice to Proceed The formal start date. The contract schedule clock begins.
Kickoff Meeting Agree on the schedule, submittal list, safety plan, and points of contact.
First 30 Days Agree in advance on the key deliverables due in the first month.
The notice to proceed date starts the contract clock, so planning should begin before it. Share a sample kickoff agenda so contractors can prepare their schedule, submittal list, and safety plan before the meeting.
File Sharing Requirement: Autodesk Build Contractors must use Autodesk Build, provided by the VA in VISN 2, for all project documents.
RFIs Submit all requests for information here.
Submittals Upload all submittal packages here.
Daily Logs and Reports Post all daily logs, progress reports, and other project records here.
Access and training: [insert how contractors request accounts]
Explain that Autodesk Build is the single system of record for project documents, so everything on the project lives in one place. Emphasize that the requirement covers RFIs, submittals, daily logs, and reports. Before presenting, confirm with the program office how contractors get accounts and training, and fill in the highlighted placeholder. Do not present a deadline that is not in the contract.
Davis-Bacon Act: Pay workers at least the locally prevailing wages listed in the wage determination.
Certified payrolls: Submit certified payrolls weekly for every worker on the project.
Subcontractors: The same wage rules apply at every tier. Primes are responsible for their subs.
Labor Compliance
Recommend that primes audit subcontractor payrolls before submitting them. Errors caught early are much easier to correct than errors found during a government review.
Safety in an Operating Hospital
Infection Control Each project uses an infection control risk assessment (ICRA) that sets controls for each work area.
Dust, Noise, Vibration Control dust, noise, and vibration, and keep barriers in place at all times.
Life Safety Interim life safety measures are required when fire protection is out of service.
This is the topic first-time VA contractors most often underestimate. Give one concrete example of a dust event and what it cost in delays and cleanup. Patients come first; every control exists to protect them.
Plan around patients: Sequence work in phases so patient services continue without interruption.
Request outages early: Utility shutdowns need advance requests and approval from facility staff.
Build in lead time: Approvals take time. Add them to your schedule from the start.
Phasing and Shutdowns
Recommend that contractors build phasing into their schedules from day one. Confirm the utility shutdown approval lead time from the contract before presenting.
Security steps: Every worker must complete the required security and background investigation steps before starting.
Badging: Submit worker names for badging in the first week of the contract.
Backup crew: Workers without approved access cannot work on site. Plan backup crew members.
Site Access and Badging
Badging approvals can take time, so submit names early. Tell contractors to plan backup workers for anyone whose clearance is pending. Confirm the current investigation requirements with the security office before presenting.
Questions Received in advance Question / Topic 1 - Any challenges involving division 27 for the 7 sites proposed would be helpful?
Question / Topic 2 - For the St. Albans project, will the Division 27 telecom and data center scope be designed to a level where subcontractors can price it at bid, and is the VA planning a set-aside for St. Albans?
Question / Topic 3 – Will the structured cabling, fiber optics, telecommunications, and data center infrastructure work be included within the overall construction contracts or procured separately?
Q&A
Badging approvals can take time, so submit names early. Tell contractors to plan backup workers for anyone whose clearance is pending. Confirm the current investigation requirements with the security office before presenting.
Question / Topic 4 - Will these projects be entirely standalone new construction or include renovations and/or tie-in to existing facilities?
Question / Topic 5 - Discuss site logistics for these projects.
Question / Topic 6 - As a part of the site walks for these projects, we'd like to see where the building utilities will tie-into existing, and any new utility runs required?
Question / Topic 7 - Will these projects include any IOT services and equipment procurement or will the PCAC contract that separately through SAM.gov?
Badging approvals can take time, so submit names early. Tell contractors to plan backup workers for anyone whose clearance is pending. Confirm the current investigation requirements with the security office before presenting.
Question / Topic 8 - Will these projects have a small business or SDVOSB set-aside? Or will they be open market?
Question / Topic 9 - We are attending as a prospective subcontractor and would like to understand the set-aside strategy for the FY27 projects. What is needed for the VA to set aside these opportunities for Veterans?
Question / Topic 10 - What acquisition strategies and small business set-asides are being considered for the individual projects, including potential opportunities for 8(a) firms?
Question / Topic 11 - Will a list of interested or prequalified contractors be available at any point on SAM.gov? Will the VA facilitate networking or share an attendee list to help specialty contractors connect with prospective prime contractors for teaming and subcontracting opportunities?
Question / Topic 12 - Is there an estimated date as to when these solicitations will be published?
Badging approvals can take time, so submit names early. Tell contractors to plan backup workers for anyone whose clearance is pending. Confirm the current investigation requirements with the security office before presenting.
Closing Remarks Sam Cornwell, Contract Specialist
Next Steps for each EHRM project Sources sought notice - market research Pre-sol notice - procurement method / set-aside Solicitation Networking Session - Feel free to speak to other participants and VA representatives for an informal networking session
Closing Remarks image3.png
Microsoft_Word_Document.docx Project scoping and funding
Advisory modification review/approval
Advisory design review
Stakeholder coordination
Schedule analysis
Advise COR/Contracting for issue resolution image4.emf image5.png image6.png image7.png image8.png image9.png
BUILDING 100
PROPOSED
DATA CENTER
EXISTING
BUILDING 8
EXISTING
BUILDING 37
UP
ENCLOSED WALKWAY
EN
CL
OS
ED
W
AL
KW
AY
TRAILER
CW
CONSTRUCTION SIGN
(SEE DETAIL 13 ON CS8003)
SAFETY SIGN
(SEE DETAIL 12 ON CS8003)
CONSTRUCTION FENCE
(SEE DETAIL 7 ON CS8003)
STABILIZED CONSTRUCTION ENTRANCE
(SEE DETAIL 8 ON CS8003)
PEDESTRIAN ACCESS TO BE
MAINTAINED DURING CONSTRUCTION
(SEE NOTES 10 & 11)
"SIDEWALK CLOSED" SIGN
MOUNTED ON FENCE
(SEE DETAIL 10 ON CS8003)
"SIDEWALK CLOSED" SIGN
MOUNTED ON FENCE
(SEE DETAIL 10 ON CS8003)
"NO PARKING ANYTIME" CONSTRUCTION
ENTRANCE SIGN TO BE MOUNTED ON
CONSTRUCTION FENCE (SEE DETAIL 11 ON CS8003)
12 FT WIDE DOUBLE SWING GATE
3 ACCESSIBLE PARKING SPACES TO BE
BARRICADED FROM USAGE DURING
CONSTRUCTION (SEE NOTE 10)
JERSEY BARRIER (TYP.)
(SEE DETAIL 6 ON CS8003)
PRELIMINARY STAGING AREA, EXISTING
CONDITIONS TO BE VERIFIED AND FINAL
STAGING AREA TO BE DETERMINED
CONSTRUCTION FENCE
(SEE DETAIL 7 ON CS8003)
BLDG 50
BLDG 37
BLDG 8
BLDG 9
BLDG 36
BLDG 118
BLDG
20 FT WIDE CONSTRUCTION
ENTRANCE (SEE NOTE 10 & 11)
STEAM
STEAM
TREE PROTECTION FENCE (TYP.)
(SEE DETAIL 4 ON CS8003)
INLET PROTECTION (TYP.)
(SEE DETAIL 1 ON CS8003)
LIGHT DUTY STORAGE AREA (SEE NOTE 8)
HEAVY DUTY STORAGE
AREA (SEE NOTE 8)
DOUBLE SWING GATE,
12 FT WIDE
D
APPROXIMATE LOCATION OF
SHALLOW STEAM TUNNEL
(SEE NOTE 8)
30.00'
.00
125.00'
110.00'
.00
150.00'
114.00'
CONSTRUCTION FENCE TO BE
LOCATED A MINIMUM OF 5 FT
FROM FACE OF CURB (TYP.)
EXISTING CHILLED
WATER LINES
TO REMAIN
LOOP ROAD
EXISTING TELECOM
DUCT BANKS
TO REMAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
CONSTRUCTION STAGING PLAN
A
FULLY SPRINKLERED
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
B
C
E
F
21 4 5 6 7 8 9 10
PhaseArchitect/Engineer of Record StampConsultant
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE
UPGRADES
400 FORT HILL AVE, CANANDAIGUA, NY 14424
09.21.2026 CM MR# Revisions Date
Sprinkler Status
AE Works, LTD.
418 Beaver Street Sewickley, PA 15143 Phone: 412-287-7333 www.aeworks.comAE WORKS®
100% BID DOCUMENTS
CONSTRUCTION AREA KEY MAP
00 40' 80'
CONSTRUCTION FENCE WITH SCREEN
G002
0 20' 40'
528A5-22-700
1. MATERIALS TO BE INSTALLED IN THE UPCOMING 48 HOURS MAY BE STAGED IN
CONSTRUCTION/STAGING AREA #1, THE MAJORITY OF THE CONSTRUCTION MATERIALS ARE TO
BE LOCATED IN CONSTRUCTION/STAGING AREA #2.
2. CONSTRUCTION ACTIVITIES SHALL BE PERFORMED DURING NORMAL WORKING HOURS (MON. - FRI. 8:00am - 4:30pm, EXCLUDING FEDERAL HOLIDAYS) UNLESS INDICATED OTHERWISE IN THE
CONTRACT DOCUMENTS OR AS FOLLOWS.
3. CERTAIN ACTIVITIES SUCH AS UTILITY SHUT DOWNS, RIGGING OF EQUIPMENT TO THE ROOF, NOISE VIBRATION GENERATING ACTIVITIES (INCLUDING DEMOLITION DRILLING FOR AN ANCHOR INSTALLATION, ETC.) WILL BE COORDINATED WITH THE COR AND WILL HAVE TO BE DONE DURING
OFF-HOURS/WEEKENDS EVEN IF NOT EXPLICITLY CALLED OUT IN THE CONTRACT DOCUMENTS.
THE DETERMINATION WILL BE MADE DURING THE COORDINATION WITH THE FACILITY.
4. IF IT IS DETERMINED THAT THE CONSTRUCTION ACTIVITIES NEED TO TAKE PLACE DURING
OFF-HOURS, THE CONTRACTOR SHALL SUBMIT AN OFF-HOURS REQUEST WITH THE DATE, START
AND FINISH TIMES, A BRIEF DESCRIPTION OF THE WORK TO BE DONE AND A JUSTIFICATION TO
THE COR. THE REQUEST SHALL INCLUDE THE PHRASE "THIS REQUEST IS AT NO ADDITIONAL
COST TO THE GOVERNMENT."
5. LOCATIONS OF THE CONSTRUCTION FENCE, TRAILER AND DUMPSTER ARE PROPOSED,
TENTATIVE LOCATIONS. EXISTING CONDITIONS TO BE VERIFIED AND FINAL LOCATIONS TO BE
APPROVED BY THE CONTRACTOR.
6. REFER TO THE GENERAL NOTES AND SOIL EROSION CONTROL PLAN CS6001 AND IMPLEMENT
EROSION AND SEDIMENT CONTROL MEASURES IN ACCORDANCE WITH THE PLANS PRIOR TO ANY
LAND DISTURBANCE.
7. FOR CONSTRUCTION/STAGING AREA #1 AND CONSTRUCTION/STAGING AREA #2 ENTRANCE
PROVIDE TRAFFIC SIGN, 'TWO WAY ACTIVE ROADWAY AHEAD, DO NOT IMPEDE ROADWAY
TRAFFIC', PROVIDE A FLAG MAN TO DIRECT TRAFFIC WHEN CONSTRUCTION VEHICLES ARE
ENTERING AND LEAVING.
8. CONTRACTOR TO VERIFY SHALLOW STEAM TUNNEL LOCATION AND DEPTH IN
CONSTRUCTION/STAGING AREA #2, DELINEATE IN FIELD, AND LIMIT TRAFFIC AND STORAGE OF
ITEMS ON IT TO LIGHT DUTY EQUIPMENT AND ITEMS.
9. CONTRACTOR TO VERIFY LOCATION OF UNDERGROUND CHILLED WATER LINES, TELECOM DUCT
BANKS, AND OTHER UNDERGROUND LINES TO PREVENT THEM FROM BEING DAMAGED.
10. SIDEWALK, CURB, ASPHALT PAVEMENT, AND PARKING/PAVEMENT STRIPING IN THE AREA OF THE
CONSTRUCTION ENTRANCE IS TO BE REPLACED AT THE END OF CONSTRUCTION.
11. ASPHALT PAVEMENT REPLACEMENT INDICATED ON THE PLANS IS TO BE STANDARD DUTY
PAVEMENT IN AREAS OF PARKING SPACES AND HEAVY DUTY PAVEMENT IN DRIVE AISLES AND
ROADWAYS.
NOTES
1 1' = 40'
CONSTRUCTION/STAGING AREA #1 PLAN2 1' = 20'
SAFETY SIGN
CONSTRUCTION SIGN
CONCRETE WALKWAY
BUILDING AREA
GRAVEL
PROPOSED LEGENDEXISTING LEGEND
Pennoni Engineering & Surveying of New York, P.C.
130 West 29th Street, 11th Floor New York, NY 10001 Phone: 212-239-7610
TELECOM MANHOLE
SIGN
AIR CONDITIONING UNIT
CLEAN OUT
CATCH BASIN
ROOF DRAIN
DRAINAGE/STORM MANHOLE
SANITARY SEWER MANHOLE
SHRUB/TREE
BUILDING/CORRIDOR
AE Works Proj. #: VCAN-004
STONE CONSTRUCTION ENTRANCE
SOIL STOCKPILE
LAWN
LIMIT OF DISTURBANCE
ASPHALT PAVEMENT
CONSTRUCTION/STAGING
AREA #1
STEAM MANHOLE
SILT FENCE/FILTER SOCK
CONCRETE WASHOUTCW
WATER LINE
DRAINAGE LINE
STEAM TUNNEL
SANITARY SEWER LINE
CONSTRUCTION/STAGING
AREA #2
(SEE NOTE 1)
DUMPSTERD
HYDRANT
LIGHT POLE
TREE PROTECTION FENCE
CHILLED WATER LINE
JERSEY BARRIER
TELECOM DUCT BANK
N u:
\A cc ou nt s\
LA
\a ew la
- c an an da ig ua n y va e hr m u pg ra de s\
S
IG
H
TS
\A
LA
- G
0.
dw g
6/
/2
:3
9:
P M image10.emf
BAILEY AVE
W W W W
W W
W W W W W W
LEBRUN RD
O
U
G
UGE UGE
UGE UGE UGE
UGE
UGEUGEUGEUGEUGEUGEUGEUGE
UGEUGEUGE
UGEUGEUGEUGEUGE
UG
UGE UGE UGE UGE UGE
COMM
EUGE
UGE UGE UGE UGE
AS
GA
WWWWW
WWWWWW
GASGASGASGAS
GAS GAS
WWWWWWWW
W W W W W W W W W W W W W W
WWWWWWW
SD
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
SS
SDSD
SS SS SS SS
UGE UGE UGE UGE UGE
COMM COMM
CP1 - ELECTRICAL MANHOLE
N:1075076.5759 E:1087100.4808
ELEV=693.50'
CP3 - ELECTRICAL MANHOLE
N:1075534.6859 E:1086762.4064
ELEV=689.52'
CP2 - WATER GATE VALVE
N:1075208.2930 E:1086812.4337
ELEV=689.26'
PARKING
GARAGE
EX
. E
LE
CT
RI
CA
L
EX. ELECTRICAL
EX. FIRE WATER
. F
IR
AT
ER
. S
AN
. S
EW
EX. SAN. SEWER
SE
RV
IC
PR
OV
ID
. G
EX. S
TO
RM
EX. GAS
EX. GAS
. W
EX. FIRE WATER EX
. W
9A
681682
EX. FENCE LINE
EX. FENCE LINE EX. FENCE LINE
. C
OM
MU
NI
TI
ON
Office of Construction and Facilities Management
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
02/12/2026
3495 Bailey Avenue, Buffalo, NY 14215
528-22-700
SITE
Revisions: Date:
A/E:
TRIPLE C -The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202
MAT PERKINS
(315) 484-5958
35% SCHEMATIC DESIGN
NOT FOR CONSTRUCTION
CIVIL SITE SURVEY PLAN
VF101
K.STRUBLEM.PERKINS
CIVIL SITE SURVEY PLAN
1"=40'F1
NOTE
CONTRACTOR TO HAND DIG OR HYDRO-EXCAVATE WITHIN 5' OF ALL EXISTING
UTILITY LOCATIONS.
BENCHMARK
THREE EXISTING CONTROL POINTS ARE USED TO SET TOPOGRAPHY ELEVATIONS BASED ON NAVD 88.
CONTROL POINT 1 BEING EXISTING ELECTRICAL MANHOLE RIM CENTER.
N:1075076.5759 E:1087100.4808
ELEV=693.50'
CONTROL POINT 2 BEING EXISTING WATERLINE GATE VALVE CENTER CENTER.
N:1075208.2930 E:1086812.4337
ELEV=689.26'
CONTROL POINT 3 BEING EXISTING ELECTRICAL MANHOLE RIM CENTER.
N:1075534.6859 E:1086762.4064
ELEV=689.52'
F/F FACE TO FACE
FF EL FINISH FLOOR ELEVATION
FG FINISH GRADE
FH FIRE HYDRANT
FL FLOW LINE
FOC FACE OF CURB
FT FEET OR FOOT
FTG FOOTING
HC HANDICAP
HCP HANDICAPPED
HDPE HIGH DENSITY POLYETHYLENE
HNDRL HANDRAIL
HORIZ HORIZONTAL
ID INSIDE DIAMETER OR INSIDE DIMENSION
INFO INFORMATION
INV INVERT
INV EL INVERT ELEVATION
LAT LATITUDE
LF LINEAR FEET (FOOT)
LOC LOCATION
LP LOW POINT
LS LUMP SUM
MATL MATERIAL
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MON MONUMENT
MTG MEETING
MULT MULTIPLE
N NORTH
NA NOT APPLICABLE
NO NUMBER
NTS NOT TO SCALE
OC ON CENTER
PC POINT OF CURVE
PCT PERCENT
PI POINT OF INTERSECTION
PL PROPERTY LINE
PRKG PARKING
PROJ PROJECT
PROP PROPOSED
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE (PLASTIC)
QTY QUANTITY
R RADIUS
RCB REINFORCED CONCRETE BOX
RCP REINFORCED CONCRETE PIPE
RD ROAD OR ROOF DRAIN
REQD REQUIRED
ROW RIGHT OF WAY
RT RIGHT
RW ROADWAY
ABBRV ABBREVIATION
ABC AGGREGATE BASE COURSE
AC ASPHALTIC CONCRETE
ACP ASPHALTIC CONCRETE PAVING
ADA AMERICANS WITH DISABILITIES ACT
AGGR AGGREGATE
APPROX APPROXIMATE
ASPH ASPHALT
ASSY ASSEMBLY
AVE AVENUE
BC BACK OF CURB
BDRY BOUNDARY
BITUM BITUMINOUS
BLDG BUILDING
BLVD BOULEVARD
BM BENCHMARK
BRG BEARING
CB CATCH BASIN
CFS CUBIC FEET PER SECOND
CL CENTER LINE
CLASS CLASSIFICATION
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO SEWER CLEAN OUT
CONC CONCRETE
CONSTR CONSTRUCTION
COORD COORDINATE
CORR CORRIDOR
CU FT CUBIC FEET
CU YD CUBIC YARD
DA DRAINAGE AREA
DAT DATUM
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DESCR DESCRIPTION
DET DETAIL
DI DROP INLET
DIA DIAMETER
DIFF DIFFERENCE
DIM DIMENSION
DIP DUCTILE IRON PIPE
DIR DIRECTION
DIST DISTANCE
DWG DRAWING
E EAST
EA EACH
EC EDGE OF CURB
EG EXISTING GRADE
EL ELEVATION
ENGR ENGINEER
ENTR ENTRANCE
EP EDGE OF PAVEMENT (PAVING)
EPA ENVIRONMENTAL PROTECTION
AGENCY
EQUIP EQUIPMENT
ERD EXISTING ROOF DRAIN
ES EDGE OF SHOULDER
ESMT EASEMENT
EST ESTIMATE
EX EXISTING
EXIST EXISTING
SD STORM DRAIN
SDMH STORM DRAIN MANHOLE
SECT SECTION
SF SQUARE FOOT (FEET)
SHLDR SHOULDER
SMH STEAM MANHOLE
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ YD SQUARE YARD
SS SANITARY SEWER
SSMH SANITARY SEWER
MANHOLE
ST STREET
STLT STREETLIGHT
STA STATION
STD STANDARD
STM STEAM
SURF SURFACE
SURV SURVEY
SW SIDEWALK
SWR SEWER
SYM SYMBOL
TAN TANGENT
TC TOP OF CURB
TD TRENCH DRAIN
TE TOP ELEVATION
TEMP TEMPORARY
THK THICKNESS
THRU THROUGH
TMH TOP OF MANHOLE
TOC TOP OF CURB
TOC WALL TOP OF CONCRETE WALL
TOF TOP OF FOOTING
TOP TOP OF WALL
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TYP TYPICAL
UGND UNDERGROUND
UNO UNLESS NOTED
OTHERWISE
UNPV RD UNPAVED ROAD
UTIL UTILITY
VAR VARIES
VC VERTICAL CURVE
VERT VERTICAL
VIC VICINITY
VOL VOLUME
W WEST
W/ WITH
W/O WITHOUT
CIVIL SHEET ABBREVIATIONS
LEGEND
CAMPUS BOUNDARY
UNDERGROUND ELECTRICAL LINE
CURB
STORM DRAIN MANHOLE
SANITARY SEWER MANHOLE
FIRE HYDRANT
STREETLIGHT
WATER GATE VALVE
SIDEWALK
EXISTING NEW
COMMTELECOMMUNICATIONS
STORM DRAIN INLET
W W
GAS
WATERLINE
SANITARY SEWER LINE
STORM DRAIN LINE
FENCE LINE
UNDERGROUND GAS LINE
SURVEY DISCLAIMER
SURVEY INFORMATION OF SITE DETERMINED FROM VA SUPPLIED AS-BUILT DRAWINGS; PHOTOGRAPHIC, VISUAL, AND LIDAR SURVEY CONDUCTED BY TRIPLE C. GROUND PENETRATING RADAR (GPR) CONDUCTED BY GPRS INC. GNSS/GPS LOCATORS USED BY GPRS INC. ARE CERTIFIED FOR SUB-METER ACCURACY.
CONSTRUCTION MAY HAVE OCCURRED ON THIS SITE SINCE THE SURVEY WAS COMPLETED. CONDITION OF THE SITE MAY VARY FROM THE SURVEYED CONDITION. CONTRACTOR TO PROVIDE UTILITY LOCATION SERVICE PRIOR TO EXCAVATION FOR VERIFICATION OF LOCATION AND DEPTH OF ALL UTILITIES TO PROVIDE NON-INTERRUPTION OF SERVICE, TO ENSURE PROPER CLEARANCE/SEPARATION, AND TO AVOID DAMAGE THERETO. UTILITIES DAMAGED THROUGH NEGLIGENCE OF THE CONTRACTOR TO OBTAIN LOCATION OF SAME SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT HIS EXPENSE.
ELECTRICAL MANHOLE
COMMUNICATION MANHOLE
BUILDING
OVERHEAD ELECTRICAL LINE OHU
1' MINOR CONTOUR
5' MAJOR CONTOUR
TRUE NORTH
GRAPHIC SCALE
1" = 40'
20' 40' 80'40' image11.emf
1-AE409
B3
54 SF
TELE. CLOS.
ELEC. CLOS.
PHYSICIAN
1-AE409
D3
1-AE406
1-AE406
1-AE410
D1
1-AE410
D5
1-AE407
1-AE407
1-AE408
1-AE408
CHIEF OF AUDIOLOGY
PROGRAM ASSISTANT
AUDIOLOGY
AUDIO OFF.
AURAL REHAB ROOM
W/C TOIL.
ENGINEERING
SND.STE.DIAG. EVAL
SND.STE.CONTROL
2544A
2548A
SND. STE. EXAM
SND. STE. EXAM
G613
G614
PHOTOCOPY
SND. STE.EXAM RM.
SND.STE.DIAG. EVAL
2567A
VIDEOFLUOROS.
HOUSEKEEPING
CONFERENCE ROOM
ABR CONTROL ROOM
EARMOLD FAB.
DIAG CONTROL RM.
2566A
AUDIO STORAGE
SPECIAL PROCEED
SPEECH PATH. OFF.
PSYCHOLOGIST
M.H.C.
PSYCHIATRIST
M.H.C.
SOCIAL WORKER
SOCIAL WORK
PSYCHIATRY
PSYCHIATRY
PSYCHIATRIST
SECRETARY
DIRECTOR PSYCHIATRY
0212P
DAY PROGRAM M.D
2694F
DAY PROGRAM
NURSE
2694D
NURSE
2694C
PSYCOLOGY
TRAINEE
CHIEF M.H.C
2682A
COPY
CHIEF D.T.C
2669A
AUDITORY STARTLE
TOILET
EDUCATIONAL THERAPY ROOM
CLOZAPINE CLINIC
DIETICIAN
GROUP THERAPY
NURSE PRACTC.
QUIET ROOM
MEN S ROOM
TRAINEE CUBICLES
0212Q
PTDS OFF.
2580A
PSYCOLOGY
NURSE CLINICIAN
ADMINSTRATOR
HBPC
G695
PTDS.PTC
PTDS.PTC
2578A GROUP THERAPY
MHBPC
OCCUPATIONAL THER.
PSYCHOLOGY
NURSE PRACTION.
AMBULATORY CARE
G760
TIOLET
NIDA PHARMACY
RESEARCH
RESEARCH
G776
G779
RESEARCH PSYCH.
SUPPORT SERV.
G592 ELECTRIC RM.
TELE. ROOM
PHYSICIANS OFF.
EXAM TREATMENT
NURSE ENT
2512 PHYSICIANS OFF.
RESIDENT
CHF.OPTHAL.
OPTHALOFFICE
OPTHALOFFICE
DARK ROOM
MINOR SURGERY ROOM
VISUAL FLD. DARK ADPT
EXAM ROOM
2502A
OPTHAMOLOGY CLINIC
2502B
RECORD STORAGE
2502C
2529 EXAM TREATMENT
SECRETRY RECEPTION
C215B
RETINAL CLINIC
CLOSET
C215C
FINANCIAL DISCLOSURE
STERILE PREP.
SOCIAL ACTIVITIES ROOM
0212U
H.A.V
STORAGE
2694A
KITCHEN
2694B
MEDICAL CARE
PHYSICIAN ACOS
NURSES OFFICE
C2-13B
M. TIOLET
W. TOILET
MAIL LOCKER
BATHROOM
MEDICAL CARE MGR.
HEALTH SYSTEMS SPEC.
2608NURSE COOR.
G687
EXAM/TREATMENT
NURSING
2602PHYSICIAN C+P
2600PHYSICIAN C+P
RECEPTION
LINEN CHUTE
G696
H.A.C
MEN
2593NEW TR
ELECT.CT.
MENS ROOM
CONFERENCE
PHARMACY
2599A
FEMALE LOCKERS
G712
H.R.M TRAINING
2597A
PATIENT TOIL.
STAFF TOIL.
RECEPTION CONTROL
H.A.C
WOMENS
ROOM
PROGRAM ASST.
NEW DATA CENTER
2135AS
READING
2135S
COMPUTER RM.
2139S
WORK RM.
2140S
OFFICE
FAST FD. SERVICE
2143S
BARBER SHOP
2104S
MECHANICAL RM.
2070W
ADP WORK AREA NO.1
2049W
BATH RM.
2074W
COMPUTER EQUIPMENT
2075W
M.R.I. OOF.
2044W
2042W
LAVATORY
2051W
2003W
I.R.M. OFF.
2083W
M.R.I. WORK SHOP
2086W
BATHROOM
2053W
M.R.I. OFFICE
2095W
M.R.I. STORAGE
2096W
CREDIT UNION
2097W
2099W
2099BW
WOMEN S TOILET
2099AW
LOUNGE
2060S
VENDING MACHINES
2058S
2007W
2034W
DENTAL ADMINSTRATION
0212CC
PATIENTS WAITING RM.
2154C
COMPUTER SPECIALIST ASM
2078W
ENTRANCE
2088W
BATH
0212DD
BATH
2006W
PRINTER STORAGE
2004W
2008W
LOUNGE / LOCKER
2013W
2009W
2011W
SUPPLIES
2037W
JANITOR
2038W
ELEC. CAB.
2039W
Room
2099II
2099JJ
2099KK
2099LL
P.C. WORK SHOP
2091W
ELEC. CLOSET
2001C
ELEV. SHAFT
STUDY & CONFERENCE
2167C
2166C
DENTAL LABORATORY
2193C
FEMALE LOCKER
2169C
ORAL HYGIENE
2164C
ORAL HYGIENE
2164AC
ORAL EXAM
2163C
ORAL EXAM
2162C
ENDO. RM
2161C
ENDO. RM
2160AC
GENERAL DENT.
2159C
2158C
DECONT.RM.
2597N
X-RAY
2156C
CHIEF DENTAL SVC
2178C
MAX. FACIAL PROS.
2192C
MAX. FACIAL PROS.
2191C
PROS
2190C
2189C
LINEN STR.
2597U
PROSTH
2187C
PERIO
2186C
2185C
ORAL SURGERY
2184C
2183C
0212FF
EAST STAIR
2156E
MALE LOCKER
2168D
2155C
PATIENTS LIBRARY
2225N
2225O
2225P
2225Q
DENTAL STORAGE
2166N
LIBRARY OFFICE
2168N
WOMEN VET COORD.
2173N
2176N
CONFERENCE ROOM
2186N
KITCHEN
2199N
DENTAL OFFICE
2202N
PROGRAM SUP.
MED.LIBRARY
2210AMED.LIBRARIAN
2215N
GENRAL LIBRARIAN
2219N
TLT
2219AN
PAT. COMPUTER RM.
2222N
GENERAL TR. RM
2170C
2171C
GENERAL TR. RM
2173C
PROS.
2172C
GENERTAL DENT.
2177C
2176C
GENERAL DENT
2174C
PROS.
2175C
2181C
DELICARESSEB DINNING ROOM
0212II
FOOD PREPARATION
2593A
ATRIUM BELOW
0212JJ
MENS ROOM
2181C
2179C
ASST. CHIEF
2179AC
ADMINISTRATION
2109C
TR DISPOSITION
DECOMMISSION
EXISTING TR TO BE EXPANDED
EXISTING TR TO REMAIN
1-AE411
D5
1-AE411
D1
69 SF
TELE. CLOS.
2012W
109 SF
NEW TR
2147C
2165C
MECH. RM.
2131S
EL. CAB.
2073S
TELECOM
2110GA
READING RM
2110FS
2110ES
2110DS
2110CS
2110BS
2110AS
2110S
CIRCULATION
2105S
NORTH STAIRWAY
- DUCT SHAFT
2160C
COMPUTER ROOM
2052W
FIRE BARRIER, 3 HOUR
FIRE BARRIER, 2 HOUR
FIRE BARRIER, 1 HOUR
SMOKE BARRIER
NEW PARTITION
EXISTING PARTITION
EXISTING CMU
DEMOLITION
WATER BARRIER
PARTITION LEGEND
5 5 10 15 20 25 30
3/64" = 1'-0"
FEETSCALE
R
T
TRUE
NORTH
of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD
STAMP
SHEET NOTES:
to d s k o c s /M a h tt
/M h tt
.r v t
:1
1-AE102
OVERALL FLOOR PLAN - 2ND FLOOR
Awen Solutions Group
215 N. Payne Street, Suite 122
Alexandria , VA 22314
01/26/2026
READINESS BLDG 1 AND 6
423 EAST 23rd STREET, NY, NY 10010
630-22-700
100% CONSTRUCTION DOCUMENTS
100% CONSTRUCTION
DOCUMENTS
TR RECOMMENDATIONS
NUMBER
ROOM NUMBER ROOM NAME BOD COMMENTS
2nd Floor
BLDG 1 AND 6 2012W TELE. CLOS. EXISTING TR TO BE EXPANDED
BLDG 1 AND 6 2135AS
NEW DATA
CENTER
BLDG 1 AND 6 2147C NEW TR EXISTING TR TO BE EXPANDED
BLDG 1 AND 6 2589 NEW TR EXISTING TR TO BE EXPANDED
BLDG 1 AND 6 2679 TELE. CLOS. EXISTING TR TO REMAIN
DECOMMISSION SCHEDULE
NUMBER
ROOM NUMBER ROOM NAME BOD COMMENTS
2nd Floor
BLDG 1 AND 6 2052W COMPUTER ROOM DECOMMISSION
BLDG 1 AND 6 2576 TELE. ROOM DECOMMISSION
Revisions: Date: SHEET 71 of 598 image12.emf
UTILITY KEYED NOTES:
1. INSTALL NEW 8" PVC C-900 WATER LINE.
2. INSTALL NEW 8" 90 DEGREE ELBOW GATE VALVE AND THRUST
BLOCKING.
3. INSTALL 8" 45 DEGREE ELBOW AND THRUST BLOCKING.
4. INSTALL 8" 22.5 DEGREE ELBOW AND THRUST BLOCKING.
5. INSTALL NEW 8" PVC SERVICE LINE TO BUILDING WITH PIV (POST
INDICATOR VALVE) AND FOUR BOLLARDS.
6. TIE NEW 8" LINE INTO EXISTING VALVE WITH NON-RISING STEM.
7. TIE NEW ROOF DRAIN INTO EXISTING STORM DRAIN.
8. INSTALL NEW 8" STORM DRAIN LINE WITH RISERS TO SURFACE FOR
ROOF DRAINING.
9. INSTALL 4" CLEANOUTS AT SURFACE.
10. INSTALL NEW 8" PVC STORM DRAIN AND CONNECT TO EXISTING
STORM DRAIN MANHOLE.
11. INSTALL NEW 77' 8" PVC SANITARY SEWER FROM BUILDING TO NEW
MANHOLE. MAINTAIN MINIMUM 0.4% SLOPE.
12. INSTALL NEW 4' 0" SANITARY SEWER MANHOLE. MANHOLE 12A
13. INSTALL 354' NEW 8" PVC SANITARY SEWER FROM NEW MANHOLE
TO EXISTING MANHOLE 12.
GENERAL NOTES:
1. EXISTING UTILITIES ARE SHOWN TO THE BEST AVAILABLE
INFORMATION. CONTRACTOR TO VERIFY UTILITY LOCATIONS W/
GPR AND POTHOLING.
2. WHERE A SEWER LINE CROSSES OR PARALLELS A POTABLE WATER
OR FIRE WATER LINE, SEWER LINE MUST BE CONCRETE ENCASED
FOR TWENTY-FIVE (25') FEET ON EACH SIDE OF THE WATER LINE, OR
AS REQUIRED BY THE AHJ OR THE GOVERNMENT. WATER LINE
SHALL BE SLEEVED WITH LARGER PIPE FOR A MINIMUM OF
TWENTY- FIVE (25') FEET FROM THE CROSSING POINT.
77 LF 8" SCH40
BLDG TIE-IN
INV 156.57 MH 12A
RIM
INV (E) 153.60
INV (S) 153.60
354 LF 8" SCH40
@0.4% FALL MH 12
RIM 155.42
INV (N)
INV ( )
1" CONDUIT (ELECT)
8" PVC (WATER)
1 SANITARY SEWER PROFILE
NTS
1 SITE PLAN - NEW DATA CENTER
SCALE: 1" = 20'-0"
EX-W EX-W EX-W EX-W
K
W-ABD W-ABD W-ABD
SIG
SI
-C
EX-E
EX-E EX-E
-E
-W
BLDG. 300
FUEL TANK
FIN. FLR. 1
@ 160.57'
FIN. FLR. T
@ 155.46'
SA
SAS SAS SAS
EX-W
W EX-W EX-W EX-W EX-W EX-W EX-W EX-W
SS-ABN
-S
EX-SS
EX-S
X-SS
EX-SS EX-SS EX-SS EX-SS EX-SS EX-SS EX-SS EX-SS
EX-SS EX-SS EX-S
MH. 12
EL. 136.59
MH. 13
EL. 138.28
MH. 13AB
EL. 134.50
MH. 22
FR.EL. 155.12
MH. 21
FR.EL. 160.27
MH. 29
FR.FL. 156.00
MH. 12A
IE(E) 153.60
IE(S) 153.50
MH. 12
FR.EL. 155.42
13MH. 13AA
FR EL. 134.48
BLDG. 12
BLDG. 11
300-C-120
SANITARY SEWER -
RAC, HR
NA
DrawnCheckedIssue Date
21 3 4 5 6 7 8 9 10
PhaseDrawing Title
Approved: Project Director
ARCHITECT OF RECORDCONSULTANTRevisions: Date:
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com
632-22-700VA EHRM INFRASTRUCTURE
UPGRADE
79 Middleville Rd Northport, NY 11768
CONSTRUCTION AGENT
US Army Corps of Engineers
NOT FOR
CONSTRUCTION
5/24/2024
0 20' 40' 60'
100% BID
-'^ -3 lvio u?h VA A N V d I/M □ 0A N V d I/M □ □
8UL /a/ ✓3HQNV fIN ^
II
ij*1 r \k rv ^/ //////////// V////////// /////// \□□
□ □ /////////////// n / //////////////// /
OOooo oo
1 oV ////// /////// / /o
(3oooooo
(3ooooo o r///// ////////// / ////////////////□□
//////////////// h□ ///////////////
(3Ooooo o ssA
Hooo ooo o
7-TTTTTTTTTTZ
^/ //// ////////// V ////// nr? ////// x
/////////// x
/ //////// A image13.emf
0 10' 20' 30'
1 NEW CONCRETE WALK
SCALE: 1" = 10'-0"
BW29.22
BW29.57
BW32.54
BW33.39
BW34.72
BW34.53
BW34.08
BW34.50
BW34.68
BW34.31
BW33.91
BW33.28
BW33.52
BW33.41
BW33.50
BW35.44
BW33.68
BW34.39
BW34.72
BW34.90
BW35.21
BW34.95
BW35.09
BW35.29
BW35.31
BW35.27
BW35.27
BW35.24
BW35.25
BW35.22
BW35.31
BW33.34
BW33.35
BW33.38
BW34.11
BW34.22
BW34.07
BW34.04
TW35.00
TW34.95
TW34.92
TW34.54
TW34.49
TW34.55
TW35.08
TW35.08
TW35.10
TW35.11
TW35.04
TW35.06
TW35.04
TW35.06
TW34.42
TW35.75
TW38.39
TW38.15
TW38.14
TW35.01
TW34.99
TW35.03
TW35.01
TW35.41
TW35.39
TW35.39
TW35.44
TW35.67
TW35.65
TW35.66
TW35.71
TW35.79
TW35.71
TW35.75
TW35.79
CONCRETE WALK
PAVEMENT
CONCRETE RAMP
ET
AM
WINDOW WELL
ELEV TO BOTTOM: 27.1
ELEV TO BOTTOM: 27.0
2'x2'GRATE (EX)
ELEV:25.32
(A)INV:22.69
(B)INV:22.64
ENCLOSED
STAIRS
UTILITY BOX
ON CONC.
PAD
A.C. UNIT
GRATE
ELEV:33.71
INV:26.88
ELEV:33.18
CONCRETE W
ALK
MULTI-STORY
BRICK & CONC.
ONE STORY
SILL33.48
SILL 34.76
SILL37.87
SILL37.81
SILL23.77
SILL 34.83
BW25.59
BW25.72
BW34.23
BW34.24
TW37.89
N:190850E:
MANHOLE
(FIRE)
A.C. UNIT
CONCRETE
CONCRETE WALL
N:190850E:
N:191050E:
N:191050E:
ELEV:23.18
BUILDING 89
BUILDING 91
29'-6''
15'-0''
10'-0''
11"
11''
5' -4
"4' -0
9'-0"
9' -0
11''
DrawnCheckedIssue Date
PhaseDrawing Title
Approved: Project Director
ARCHITECT OF RECORDCONSULTANTRevisions: Date:
630A4-22-710
08/07/2026
St. Albans VA Medical Center - EHRM Infrastructure Upgrades
179-00 Linden Boulevard Queens, NY 11424-14-68
KEYED NOTES
CONCRETE
C-300
NEW SITE PLAN
DM
DATA CENTER
NJA
1. ALL INFORMATION SHOWN TO THE BEST OF
KNOWN ACCURACY BASED ON TOPOGRAPHIC,
GROUND-PENETRATING RADAR AND VISUAL
ONSITE SURVEYS IN ADDITION TO ASBUILT
INFORMATION.
2. CONTRACTOR SHALL PROVIDE AND MAINTAIN A
STORM WATER POLLUTION PREVENTION PLAN
(SWPPP) COMPLIANT WITH VA AND EPA
REQUIREMENTS. PLAN TO BE UPDATED AND
MAINTAINED ONSITE FOR INSPECTIONS.
3. CONTRACTOR SHALL MAINTAIN AND PROTECT
STORM DRAINAGE AT ALL TIMES.
4. CONTRACTOR SHALL KEEP SITE CLEAN AND FREE
OF TRASH OR OTHER DEBRIS. TRASH OR DEBRIS
TO BE PLACED AND SECURED IN COVERED BINS
OR DUMPSTER.
5. CONTRACTOR SHALL VERIFY ALL SITE UTILITIES
AND FEATURES IN THE FIELD PRIOR TO
EXCAVATION, AFTER CALLING FOR UTILITY
LOCATING SERVICES.
6. IF ANY DIFFERING SITE CONDITIONS ARE
ENCOUNTERED, CONTACT COR PRIOR TO
PERFORMING ANY WORK.
7. ALL UTILITY WORK TO COMPLY WITH VA AND
LOCAL UTILITY, CITY, OR STATE REQUIREMENTS.
8. CONTRACTOR SHALL PROVIDE TEMPORARY SITE
FENCING.
9. ALL EXCAVATIONS SHALL COMPLY WITH OSHA OR
MORE STRINGENT REQUIREMENTS, IF ANY. A
COMPETENT PERSON MUST INSPECT ALL
EXCAVATIONS EACH DAY PRIOR TO PERSONNEL
ENTRY.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
AIR QUALITY OR OTHER REQUIRED PERMITS.
11. CONTRACTOR SHALL SET ALL UTILITY VAULTS,
MANHOLES, BOXES, AND INLETS FLUSH WITH NEW
PAVING.
12. CONTRACTOR SHALL PROVIDE FOR APPROVAL,
SHOP DRAWINGS OF NEW SIDEWALK AND CURBS
WHERE INDICATED TO BE COORDINATED WITH
COR. BEFORE STARTING WORK.
13. CONTRACTOR SHALL PROVIDE AND MAINTAIN
TEMPORARY TRAFFIC CONTROL FOR PEDESTRIAN
AND VEHICLE TRAFFIC THROUGHOUT
CONSTRUCTION.
14. CONTRACTOR SHALL RESTORE ALL AREAS
AFFECTED BY CONSTRUCTION ACTIVITIES TO
THEIR ORIGINAL CONDITION OR BETTER AFTER
COMPLETION OF WORK.
GENERAL NOTES
1. EXISTING CONCRETE WALK.
2. NEW CONCRETE WALK. REF.1/C-500
3. NEW CONCRETE WALK TO BE FLUSH WITH THE
NEW DATA CENTER CONCRETE STOOP.
4. NEW CURB RAMP REF. 2/C-500
5. CONTRACTOR SHALL BE RESPONSIBLE FOR
RESTORING ALL DISTURBED AREAS TO THEIR
ORIGINAL CONDITION UPON COMPLETION OF
CONSTRUCTION.
6. SAW CUT THE EXISTING CONCRETE WALK TO
MATCH THE NEW CONCRETE WALK
7. NEW CONCRETE WALK STEPS. REF.3/C-500
8. PROVIDE 9 INCHES DIAMETER BOLLARDS - M30 P1
RATED. DISTANCE OF 4 FEET BETWEEN THE
OUTSIDE EDGE OF EACH BOLLARD, 36" ABOVE
GRADE AND 48" BELOW GRADE WITH A CONCRETE
PIER 30" DIAMETER. BOLLARDS PAINTED YELLOW
REF.1/C-520
9. REMOVABLE BOLLARDS - M30 P1 RATED
BOLLARD
EX-SD EXISTING STORM DRAIN
STORM GRATE
7August 2026 image14.emf
CO
UT
UT UT
EE
COMCOM
COM
COM COM COM
COM COM COM
G G
GG
E E
CURBCUT
CURBCUT
SCALE: 1" = '
0 50 100
EXISTING CONDITIONS AND DEMO PLAN -
OVERALL
CD100117 STATE STREET, SUITE 201
BETTENDORF, IA
52722
PH: 563.344.0260
www.imegcorp.com
IMEG #23001093
ARCHITECT/ ENGINEER OF RECORD
STAMPCONSULTANT/ DISCIPLINE
DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032 VA NJ EAST ORANGE
385 TREMONT AVE., EAST ORANGE NJ 07018
UPGRADES - EAST ORANGE
561-22-700
LKS PTD
08/13/2026 Revisions: Date:
LINNEA K.
SHAW
062-074863
CD101
CD102 CD103
CD104
8/
1:
PM
image15.emf
BASKETBALL
COURT
STUCCO
LANDSCAPE
LANDSCAPE
FHCP
MAIN ENTRY
BUILDING 100
FISHER HOUSE 1
FISHER HOUSE 2
BUILDING 105
BUILDING 106
BUILDING 110
CHAPEL
BUILDING 101
BUILDING 107
BUILDING 016
TRAILERS
TRAILER
BUILDING 113
BUILDING 114
BUILDING 118
WEBB AVENUE
SEDGWICK AVENUE
IN
ID
BLDG 100
* DECOMMISSION 42 EXISTING TRs
* ADD 30 NEW TRs UTILIZING 2 NEW TOWERS AND
EXISTING DUMBWAITER STACK
* 1 EXISTING BIOMED TR TO REMAIN
* 2 DATA CENTERS TO REMAIN
* ADD 1 TR ON LEVELS 00, 01, 02, & 03 EACH
TO SUPPORT WING D
BLDG 105
* DECOMMISSION 11 EXISTING TRs
* ADD 1 TE ON L00
* ADD 1 TR ON EACH LEVEL (00, 01, 02, 03, 04 & 05)
* 1 EXISTING EXTERNAL DATA CENTER TO REMAIN
BLDG 106
* DECOMMISSION 4 EXISTING TRs
* ADD 1 TE ON LEVELS 01 & 02 EACH
* ADD 1 TR ON L02
BLDG 115
* REQUIRES NEW FIBER
* EXISTING TR TO REMAIN
FISHER HOUSES
* EXISTING TR TO REMAIN
BLDG 016
* DECOMMISSION 1
EXISTING TR
* ADD 1 TE ON LEVELS
00, 01 & 02 EACH
BLDG 101
* ADD TE ON LEVEL 01
BLDG 107
* DECOMMISSION 2 EXISTING TRs
* ADD TR ON LEVEL 01
BLDG 110
*ADD TE ON LEVEL 01
BLDG 113
*RECEIVE CABLE
DISTRIBUTION FROM
ADJACENT TE OR TR
FROM BUILDING 101
BLDG 114
FROM BUILDING 100
FROM BUILDING 100
AMBULANCE ACCESS NEEDS TO
BE MAINTAINED
50FT MIN. DISTANCE FROM DATA
CENTER TO CURB (UNSECURED
ACCESS) TO THE SOUTH.
SECURED ACCESS TO THE
NORTH OF DATA CENTER AND
STANDOFF DISTANCE OF 5FT.
BUILDINGS IN SCOPE
BLDG 016
BLDG 100
BLDG 101
BLDG 105
BLDG 106
BLDG 107
BLDG 110
BLDG 113
BLDG 114
FISHER HOUSES
RESEARCH TRAILER
VACANT (NON-CLINICAL)
MAIN HOSPITAL (CLINICAL)
SERVICE/BOILER/ENERGY CENTER (NON-CLINICAL)
RESEARCH BUILDING (CLINICAL)
EXTENDED CARE FACILITY/NURSING (CLINICAL)
CHAPEL/OCC HEALTH (CLINICAL)
THERAPEUTIC POOL (CLINICAL)
MOTOR POOL (CLINICAL)
MRI (CLINICAL)
LINEAR ACCELERATOR (CLINICAL)
VISN (NON-CLINICAL)
(NON-CLINICAL)
CAMPUS BUILDING IDENTIFICATION LEGEND
PLAN
NORTH TRUE
of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD
STAMP
FOR OFFICIAL USE ONLY
to k c s /J m
J te rs V ic l te r (J
J ro x
/5
-2
-7
.G
.B
X .r v t
:0
:1
00-GS101
CAMPUS SITE PLAN
Awen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
10/29/2025
130 W KINGSBRIDGE ROAD
BRONX, NY 10468
526-22-700
FINAL BID DOCUMENTS
FINAL BID DOCUMENTS
60 60 120
1" = 60'-0"
FEETSCALE
Revisions: Date: SHEET 12 of 639 image16.emf image1.png…